Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Why Seeding Works When Nucleation Barriers Vanish

Crystallization is a process governed by the interplay between nucleation and growth. While crystalline seeds are known to reduce nucleation barriers and accelerate crystallization under nucleation-limited conditions, their influence when nucleation is not the limiting step remains poorly understood. This creates a mechanistic puzzle in systems where nucleation barriers are already negligible, yet seeding still accelerates crystallization. Here, the synthesis of zeolites is a quintessential example of growth-limited crystallization in which seeds accelerate the process despite negligible homogeneous nucleation barriers. Using coarse-grained molecular dynamics simulations─validated across two zeolites and the unrelated case of ice crystallization─we establish that growth-limited crystallization produces many small, misoriented crystallites whose slow coarsening into larger domains controls the emergence of X-ray-detectable crystallinity. Local crystalline order, structural coherence, and X-ray detectability are therefore kinetically decoupled milestones: the first can be reached rapidly while the latter two lag significantly. Seeds resolve this lag by imposing a common orientational registry on nascent crystallites, enabling their coherent coalescence into large seed-bound domains. This early coherence-building step produces a crystallite-size asymmetry that accelerates subsequent coarsening, advancing the onset of X-ray-detectable crystallinity without necessarily increasing the nucleated fraction. We conclude that under growth-limited conditions, the apparent induction period observed in powder X-ray diffraction reflects the time required to build long-range coherence, not the time to form crystalline material. Accordingly, seeds function not primarily by reducing nucleation barriers but by enforcing spatial coherence, thereby shortening the time required to develop long-range order detectable by X-ray diffraction.

Growth-Limited Crystallization↗

Dynamical nonlinear memory capacitance in biomimetic membranes

Two-terminal memory elements, or memelements, capable of co-locating signal processing and memory via history-dependent reconfigurability at the nanoscale are vital for next-generation computing materials striving to match the brain’s efficiency and flexible cognitive capabilities. While memory resistors, or memristors, have been widely reported, other types of memelements remain underexplored or undiscovered. Here we report the first example of a volatile, voltage-controlled memcapacitor in which capacitive memory arises from reversible and hysteretic geometrical changes in a lipid bilayer that mimics the composition and structure of biomembranes. We demonstrate that the nonlinear dynamics and memory are governed by two implicitly-coupled, voltage-dependent state variables—membrane radius and thickness. Further, our system is capable of tuneable signal processing and learning via synapse-like, short-term capacitive plasticity. These findings will accelerate the development of low-energy, biomolecular neuromorphic memelements, which, in turn, could also serve as models to study capacitive memory and signal processing in neuronal membranes.

59 BASIC BIOLOGICAL SCIENCES↗

SU-F-P-11: Long Term Dosimetric Stability of 6 TomoTherapy Systems

Purpose: The dosimetric stability of six TomoTherapy units was analyzed to investigate changes in performance over time and with system upgrades. Methods: Energy and output were tracked using monitor chamber signal, onboard MVCT detector signal and external ion chamber measurements. The systems (and monitoring periods) include 3 Hi-Art (67, 61 and 65 mos.), 2 HDA (29 and 25 mos.) and one research unit (7 mo.). Dose Control Stability system (DCS) was installed on 4 systems. Output stability is reported as deviation from reference monitor chamber signal for all systems, and from an external chamber for 4 systems. Energy stability was monitored using the relative (center versus off-axis) MVCT detector signal and/or the ratio of chamber measurements at 2 depths. The results from the clinical systems were used to benchmark the stability of the research unit, which has the same linear accelerator but runs at a higher dose rate. Results: The output based on monitor chamber data of all six systems is very stable. Non- DCS had a standard deviation of 1.7% and 1.8%. As expected, DCS systems had improved standard deviation: 0.003–0.05%. The energy was also very stable for all units. The standard deviation in exit detector flatness was 0.02–0.3%. Ion chamber output and 20/10 cm ratios supported these results. The stability for the research system, as monitored with a variety of metrics, is on par with the existing systems. Conclusion: The output and energy of six TomoTherapy units over a total of almost 10 years is quite stable. For each system, the results are consistent between the different measurement tools and techniques, proving not only the dosimetric stability, but that these quality parameters can be confirmed with various metrics. A research unit operating at a higher dose rate performed as well as the clinical treatment units. University of Wisconsin and Accuray Inc. (vendor of TomoTherapy systems) have a research agreement which supplies funds for research to the University. This project was partially supporting with these funds.

60 APPLIED LIFE SCIENCES↗

Production of Cf-252 and other transplutonium isotopes at Oak Ridge National Laboratory

In 1957 Glenn T. Seaborg conceived and advocated for the construction of the High Flux Isotope Reactor (HFIR) and the Transuranium Processing Plant (since then renamed the Radiochemical Engineering Development Center, or REDC) at Oak Ridge National Laboratory. There, heavily shielded hot cells, glove boxes, and laboratories allow recovery of transuranium elements produced in substantial quantities. Seaborg’s vision of HFIR and REDC producing milligram quantities of berkelium, californium, and einsteinium has been fulfilled beginning in 1966 through May 2019 with 78 production campaigns yielding a cumulative totals of 1.2 g of 249 Bk, 10.2 g of 252 Cf, 39 mg of 253 Es, and 15 pg of 257 Fm. Notably, 252 Cf is a neutron source used in many industrial applications including oil exploration; process control systems for the cement industry, coal analysis, and power production; sources to start nuclear reactors and perform nondestructive materials analyses; homeland security and national defense detection devices; and medical research. Isotopes made available through transplutonium production at HFIR/REDC have enabled scientists to study the nuclear properties and reactions, chemical properties, optical properties, and solid-state properties of transplutonium elements. Long-lived isotopes have served as targets in heavy ion accelerators to produce heavier elements leading to the discovery of 104 Rf, 105 Db, 106 Sg, 113 Nh, 114 Fl, 115 Mc, 116 Lv, 117 Ts, and 118 Og. This paper reviews the evolution of the processing flowsheets to produce, separate, and purify transplutonium isotopes, which have evolved over 50 years of operation at HFIR and REDC, and summarizes directions of future work to improve the efficiency of the production operations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

New understandings of failure modes in SSL luminaires

As SSL products are being rapidly introduced into the market, there is a need to develop standard screening and testing protocols that can be performed quickly and provide data surrounding product lifetime and performance. These protocols, derived from standard industry tests, are known as ALTs (accelerated life tests) and can be performed in a timeframe of weeks to months instead of years. Accelerated testing utilizes a combination of elevated temperature and humidity conditions as well as electrical power cycling to control aging of the luminaires. In this study, we report on the findings of failure modes for two different luminaire products exposed to temperature-humidity ALTs. LEDs are typically considered the determining component for the rate of lumen depreciation. However, this study has shown that each luminaire component can independently or jointly influence system performance and reliability. Material choices, luminaire designs, and driver designs all have significant impacts on the system reliability of a product. From recent data, it is evident that the most common failure modes are not within the LED, but instead occur within resistors, capacitors, and other electrical components of the driver. Insights into failure modes and rates as a result of ALTs are reported with emphasis on component influence on overall system reliability.

Shepherd, Sarah D↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laser produced streams of Ge ions accelerated and optimized in the electric fields for implantation into SiO{sub 2} substrates

Ge crystals were prepared by means of laser-induced ion implantation technique. A Nd:YAG pulsed laser (repetition rate: 10 Hz; pulse duration: 3.5 ns; pulse energy: {approx}0.5 J) was used both as an ion source and to carry out the ablation processes. The optimization of the laser-generated ion beam parameters in a broad energy and current density range has been obtained controlling the electrostatic field parameters. Numerical simulations of the focusing system, performed adopting an OPERA 3D code, and an investigation of the ion characteristics, using the ion time-of-flight method, have allowed to optimize the preparation parameters. The structural properties of the samples were investigated by means of x-ray photoelectron, micro-Raman spectroscopies, and scanning electron microscopy techniques. Experimental results show that, by appropriately varying the ion implantation parameters and by a post-preparation annealing treatment, it is possible to achieve the development of a micrometer-sized crystalline Ge phase and/or an amorphous one.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavefront Measurement for Laser-Guiding Diagnostic

The wavefront of a short laser pulse after interaction in a laser-plasma accelerator (LPA) was measured to diagnose laser-guiding quality. Experiments were performed on a 100 TW class laser at the LOASIS facility of LBNL using a hydrogen-filled capillary discharge waveguide. Laser-guiding with a pre-formed plasma channel allows the laser pulse to propagate over many Rayleigh lengths at high intensity and is crucial to accelerate electrons to the highest possible energy. Efficient coupling of laser energy into the plasma is realized when the laser and the channel satisfy a matched guiding condition, in which the wavefront remains flat within the channel. Using a wavefront sensor, the laser-guiding quality was diagnosed based on the wavefront of the laser pulse exiting the plasma channel. This wavefront diagnostic will contribute to achieving controlled, matched guiding in future experiments.

43 PARTICLE ACCELERATORS↗

Use of volumetric-modulated arc therapy for treatment of Hodgkin lymphoma

To evaluate volumetric-modulated arc therapy (VMAT) for treatment of Hodgkin lymphoma (HL) in patients where conventional radiotherapy was not deliverable. A planning computed tomography (CT) scan was acquired for a twelve-year-old boy with Stage IIIB nodular sclerosing HL postchemotherapy with positive positron emission tomography scan. VMAT was used for Phase 1 (19.8 Gy in 11 fractions) and Phase 2 (10.8 Gy in 6 fractions) treatment plans. Single anticlockwise arc plans were constructed using SmartArc (Philips Radiation Oncology Systems, Fitchburg, WI) with control points spaced at 4°. The inverse-planning objectives were to uniformly irradiate the planning target volume (PTV) with the prescription dose while keeping the volume of lung receiving greater than 20 Gy (V{sub 20} {sub Gy}) to less than 30% and minimize the dose to the other adjacent organs at risk (OAR). Pretreatment verification was conducted and the treatment delivery was on an MLCi Synergy linear accelerator (Elekta Ltd, Crawley, UK). The planning results were retrospectively confirmed in a further 4 patients using a single PTV with a prescribed dose of 19.8 Gy in 11 fractions. Acceptable dose coverage and homogeneity were achieved for both Phase 1 and 2 plans while keeping the lung V{sub 20} {sub Gy} at 22.5% for the composite plan. The beam-on times for Phase 1 and Phase 2 plans were 109 and 200 seconds, respectively, and the total monitor units were 337.2 MU and 292.5 MU, respectively. The percentage of measured dose points within 3% and 3 mm for Phase 1 and Phase 2 were 92% and 98%, respectively. Both plans were delivered successfully. The retrospective planning study showed that VMAT improved PTV dose uniformity and reduced the irradiated volume of heart and lung, although the volume of lung irradiated to low doses increased. Two-phased VMAT offers an attractive option for large volume sites, such as HL, giving a high level of target coverage and significant OAR sparing together with efficient delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Variational Optical Phase Learning on a Continuous-Variable Quantum Compiler

Quantum process learning is a fundamental primitive that draws inspiration from machine learning with the goal of better studying the dynamics of quantum systems. One approach to quantum process learning is quantum compilation, whereby an analog quantum operation is digitized by compiling it into a series of basic gates. While there has been significant focus on quantum compiling for discrete-variable systems, the continuous-variable (CV) framework has received comparatively less attention. We present an experimental implementation of a CV quantum compiler that uses two-mode squeezed light to learn a Gaussian unitary operation. We demonstrate the compiler by learning a parameterized linear phase unitary through the use of target and control phase unitaries to demonstrate a factor of 5.4 increase in the precision of the phase estimation and a 3.6-fold acceleration in the time-to-solution metric when leveraging quantum resources. We further show how our approach can be extended to higher-dimensional compilation tasks. Our results are enabled by the tunable control of our cost landscape via variable squeezing, thus providing a critical framework to simultaneously increase precision and reduce time-to-solution.

97 MATHEMATICS AND COMPUTING↗

Runtime System for I/O Staging in Support of In-Situ Processing of Extreme Scale Data

Our research in this project focused on creating and evaluating an I/O infrastructure and tools for extreme-scale applications and machines so that scientists can reduce their time to discovery at small cost in machine resources and consequent power consumption. We wanted to provide tools that are highly scalable, portable, and easy-to-use, so that scientists can gain control of their science, and concentrate on producing important scientific discovery in their own domain. Accelerating the rate of insight and scientific productivity, therefore, demands new solutions to managing the avalanche of data expected at extreme scale.

97 MATHEMATICS AND COMPUTING↗

CFD-Guided Combustion System Optimization of a Gasoline Range Fuel in a Heavy-Duty Compression Ignition Engine Using Automatic Piston Geometry Generation and a Supercomputer

A computational fluid dynamics (CFD) guided combustion system optimization was conducted for a heavy-duty diesel engine running with a gasoline fuel that has a research octane number (RON) of 80. The goal was to optimize the gasoline compression ignition (GCI) combustion recipe (piston bowl geometry, injector spray pattern, in-cylinder swirl motion, and thermal boundary conditions) for improved fuel efficiency while maintaining engine-out NO x within a 1-1.5 g/kW-hr window. The numerical model was developed using the multi-dimensional CFD software CONVERGE. A two-stage design of experiments (DoE) approach was employed with the first stage focusing on the piston bowl shape optimization and the second addressing refinement of the combustion recipe. For optimizing the piston bowl geometry, a software tool, CAESES, was utilized to automatically perturb key bowl design parameters. This led to the generation of 256 combustion chamber designs evaluated at several engine operating conditions. The second DoE campaign was conducted to optimize injector spray patterns, fuel injection strategies and in-cylinder swirl motion for the best performing piston bowl designs from the first DoE campaign. This comprehensive optimization study was performed on a supercomputer, Mira, to accelerate the development of an optimized fuel-efficiency focused design. Compared to the production combustion system in the baseline engine, the new combustion recipe from this study showed significantly improved closed-cycle fuel efficiency across key engine operating points while meeting the engine-out NO x targets. Optimized piston bowl designs and injector spray patterns were predicted to provide enhanced in-cylinder air utilization and more rapid mixing-controlled combustion, thereby leading to a fuel efficiency improvement. In addition, shifting the engine thermal boundary conditions toward leaner operation was also key to the improved fuel efficiency.

33 ADVANCED PROPULSION SYSTEMS↗

IceCube: An Instrument for Neutrino Astronomy

Neutrino astronomy beyond the Sun was first imagined in the late 1950s; by the 1970s, it was realized that kilometer-scale neutrino detectors were required. The first such instrument, IceCube, is near completion and taking data. The IceCube project transforms a cubic kilometer of deep and ultra-transparent Antarctic ice into a particle detector. A total of 5,160 optical sensors are embedded into a gigaton of Antarctic ice to detect the Cherenkov light emitted by secondary particles produced when neutrinos interact with nuclei in the ice. Each optical sensor is a complete data acquisition system, including a phototube, digitization electronics, control and trigger systems and LEDs for calibration. The light patterns reveal the type (flavor) of neutrino interaction and the energy and direction of the neutrino, making neutrino astronomy possible. The scientific missions of IceCube include such varied tasks as the search for sources of cosmic rays, the observation of Galactic supernova explosions, the search for dark matter, and the study of the neutrinos themselves. These reach energies well beyond those produced with accelerator beams.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-473: A Patient-Specific QC Paradigm Based On Trajectory Log Files and DICOM Plan Files

Purpose: To evaluate a remote QC tool for monitoring treatment machine parameters and treatment workflow. Methods: The Varian TrueBeamTM linear accelerator is a digital machine that records machine axis parameters and MLC leaf positions as a function of delivered monitor unit or control point. This information is saved to a binary trajectory log file for every treatment or imaging field in the patient treatment session. A MATLAB analysis routine was developed to parse the trajectory log files for a given patient, compare the expected versus actual machine and MLC positions as well as perform a cross-comparison with the DICOM-RT plan file exported from the treatment planning system. The parsing routine sorts the trajectory log files based on the time and date stamp and generates a sequential report file listing treatment parameters and provides a match relative to the DICOM-RT plan file. Results: The trajectory log parsing-routine was compared against a standard record and verify listing for patients undergoing initial IMRT dosimetry verification and weekly and final chart QC. The complete treatment course was independently verified for 10 patients of varying treatment site and a total of 1267 treatment fields were evaluated including pre-treatment imaging fields where applicable. In the context of IMRT plan verification, eight prostate SBRT plans with 4-arcs per plan were evaluated based on expected versus actual machine axis parameters. The average value for the maximum RMS MLC error was 0.067±0.001mm and 0.066±0.002mm for leaf bank A and B respectively. Conclusion: A real-time QC analysis program was tested using trajectory log files and DICOM-RT plan files. The parsing routine is efficient and able to evaluate all relevant machine axis parameters during a patient treatment course including MLC leaf positions and table positions at time of image acquisition and during treatment.

60 APPLIED LIFE SCIENCES↗

SU-F-T-467: A Cross-Checking Approach for Dosimetric Verification of Beam- Matched Elekta Linear Accelerators

Purpose: To verify the similarity of the dosimetric characteristics between two Elekta linear accelerators (linacs) in order to treat patients interchangeably on these two machines without re-planning. Methods: To investigate the viability of matching the 6 MV flattened beam on an existing linac (Elekta Synergy with Agility head) with a recently installed new linca (Elekta Versa HD), percent depth doses (PDD), flatness and symmetry output factors were compared for both machines. To validate the beam matching among machines, we carried out two approaches to cross-check the dosimetrical equivalence: 1) the prior treatment plans were re-computed based on the newly built Versa HD treatment planning system (TPS) model without changing the beam control points; 2) The same plans were delivered on both machines and the radiation dose measurements on a MapCheck2 were compared with TPS calculations. Three VMAT plans (Head and neck, lung, and prostate) were used in the study. Results: The difference between the PDDs for 10×10 cm{sup 2} field at all depths was less than 0.8%. The difference of flatness and symmetry for 30×30 cm{sup 2} field was less than 0.8%, and the measured output factors varies by less than 1% for each field size ranging from 2×2 cm2 to 40×40 cm{sup 2}. For the same plans, the maximum difference of the two calculated dose distributions is 2% of prescription. For the QA measurements, the gamma index passing rates were above 99% for 3%/3mm criteria with 10% threshold for all three clinical plans. Conclusion: A beam modality matching between two Elekta linacs is demonstrated with a cross-checking approach.

43 PARTICLE ACCELERATORS↗

Design of the DUNE APATF cryogenic system

Fermi National Accelerator Laboratory (FNAL) is developing the international Long- Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) to advance neutrino science. The flagship of the DUNE project consists of a large particle detector constructed one-mile (1.6 km) beneath the surface at the Sanford Underground Research Facility (SURF) in Lead, SD. The SURF detector is the largest of its type ever built and is comprised of four cryostats totaling 70,000 tons of liquid argon (LAr) to record neutrino interactions with unprecedented precision. Each cryostat houses a detector, the first includes 150 Anode Panel Assemblies (APA) submersed within 17,500 tons of LAr. Before installing 150 APA within the SURF detector they will be cryogenically cooled to nominally 90 K at the APA Test Facility (APATF) utilizing nitrogen flows. The APATF cryogenic system is entirely located one-mile underground at the SURF facility and includes nominally 13 kW of refrigeration at 80 K, cryogenic transfer lines, APA test cryostats, a cryogenic control system, and various control and pressure safety elements to ensure performance and safety requirements are achieved. The APATF preliminary design is in progress and major considerations include an efficient, costeffective mechanism to deliver the required refrigeration to the APATF underground, support of rigid testing intervals to support the DUNE operating schedule, temperature stability of the APA and electronics within cryostats, efficient cryogenic system operation to minimize heat leak and/or liquid nitrogen consumption, thermo-mechanical stability and flexibility of components, and pressure safety of the APATF cryogenic system. Installation and integration of the APATF cryogenic system within the footprint and to adjacent sub-systems is also discussed.

43 PARTICLE ACCELERATORS↗

Design Specification for Beam Containment System Ion Chamber Gas Systems

Ionization chambers are used at SLAC as protection devices near collimators, dumps and areas where beam loss must be limited through engineering controls. The two detector technologies considered in this note are Protection Ionization Chambers (PICs) and Long Ionization Chambers (LIONs). The ionization chambers are typically installed in redundant pairs and are set by introducing a controlled beam loss and using the measurements to determine a trip current setting. As such, the trip setting for any installation is specific to the system and is usually reestablished following any change in the system (change of gas, operating pressure, detector placement).

Accelerators↗

Integration of Ultrawide Bandgap Photoconducting Semiconductor Switches into High-Voltage, High-Current Pulser Systems

In this feasibility study we will evaluate the viability of integrating ultrawide bandgap (UWBG) photoconducting semiconductor switches (PCSS) in high-voltage pulser systems capable of driving low-impedance dynamic loads critical for next-generation accelerator and RF-source applications. The project consisted of developing modelling tools that would inform design of UWBG PCSS packages that could be mounted onto conventional circuit boards. Specifically, we are interested in evaluating the following through simulation software: (1) resistance to electrical breakdown (2) proximity effects due to high-frequency skin effect (3) transient behavior from switching (4) effective transmission of RF signals (5) thermal dynamics of the switch under operation (6) sensitivity to inhomogeneities in optical excitation of the material (7) cross-talk effects from parallel switching structures, and (8) susceptibility of system to damaged components. The project resulted in the development of a special-purpose circuit code that implements photoconductivity physics. This code was used to evaluate objectives 1-6 above, identifying a critical requirement associated with the need for fine control of dopant concentrations in the UWBG material to reach an optimal solution for voltage standoff and laser light responsivity requirements. In addition, we identified that the temperature dependence of the electrical conductivity of this material was typically not well-measured and developed a platform for measuring both the “dark” and “illuminated” conductivity on real physical switches in the lab to better inform our models.

24 POWER TRANSMISSION AND DISTRIBUTION↗