Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Space-Charge Compensation Using Electron Columns at IOTA

Beam loss due to space charge is a major problem at current and future high intensity particle accelerators. The space charge force can be compensated for proton or ion beams by creating a column of electrons with a charge distribution matched to that of the beam, maintaining electron-proton stability. The column is created by the beam ionizing short sections of high pressure gas. The ionization electrons are then shaped appropriately using electric and magnetic fields. The Integrable Optics Test Accelerator (IOTA) at Fermilab is a test bed for beam loss and instability mitigation techniques. Simulations using the particle-in-cell code, Warp, have been made to track the evolution of both the electron column and the beam over multiple passes. A 2.5 MeV proton beamline is under construction at IOTA, to be used to study the effect of the electron column on a space charge dominated beam.

43 PARTICLE ACCELERATORS↗

Single-shot electro-optic sampling of coherent transition radiation at the A0 Photoinjector

Future collider applications and present high-gradient laser plasma wakefield accelerators operating with picosecond bunch durations place a higher demand on the time resolution of bunch distribution diagnostics. This demand has led to significant advancements in the field of electro-optic sampling over the past ten years. These methods allow the probing of diagnostic light such as coherent transition radiation or the bunch wakefields with sub-picosecond time resolution. Potential applications in shot-to-shot, non-interceptive diagnostics continue to be pursued for live beam monitoring of collider and pump-probe experiments. Related to our developing work with electro-optic imaging, we present results on single-shot electro-optic sampling of the coherent transition radiation from bunches generated at the A0 photoinjector.

43 PARTICLE ACCELERATORS↗

Monte Carlo-based treatment planning system calculation engine for microbeam radiation therapy

Purpose: Microbeam radiation therapy (MRT) is a synchrotron radiotherapy technique that explores the limits of the dose-volume effect. Preclinical studies have shown that MRT irradiations (arrays of 25-75-{mu}m-wide microbeams spaced by 200-400 {mu}m) are able to eradicate highly aggressive animal tumor models while healthy tissue is preserved. These promising results have provided the basis for the forthcoming clinical trials at the ID17 Biomedical Beamline of the European Synchrotron Radiation Facility (ESRF). The first step includes irradiation of pets (cats and dogs) as a milestone before treatment of human patients. Within this context, accurate dose calculations are required. The distinct features of both beam generation and irradiation geometry in MRT with respect to conventional techniques require the development of a specific MRT treatment planning system (TPS). In particular, a Monte Carlo (MC)-based calculation engine for the MRT TPS has been developed in this work. Experimental verification in heterogeneous phantoms and optimization of the computation time have also been performed. Methods: The penelope/penEasy MC code was used to compute dose distributions from a realistic beam source model. Experimental verification was carried out by means of radiochromic films placed within heterogeneous slab-phantoms. Once validation was completed, dose computations in a virtual model of a patient, reconstructed from computed tomography (CT) images, were performed. To this end, decoupling of the CT image voxel grid (a few cubic millimeter volume) to the dose bin grid, which has micrometer dimensions in the transversal direction of the microbeams, was performed. Optimization of the simulation parameters, the use of variance-reduction (VR) techniques, and other methods, such as the parallelization of the simulations, were applied in order to speed up the dose computation. Results: Good agreement between MC simulations and experimental results was achieved, even at the interfaces between two different media. Optimization of the simulation parameters and the use of VR techniques saved a significant amount of computation time. Finally, parallelization of the simulations improved even further the calculation time, which reached 1 day for a typical irradiation case envisaged in the forthcoming clinical trials in MRT. An example of MRT treatment in a dog's head is presented, showing the performance of the calculation engine. Conclusions: The development of the first MC-based calculation engine for the future TPS devoted to MRT has been accomplished. This will constitute an essential tool for the future clinical trials on pets at the ESRF. The MC engine is able to calculate dose distributions in micrometer-sized bins in complex voxelized CT structures in a reasonable amount of time. Minimization of the computation time by using several approaches has led to timings that are adequate for pet radiotherapy at synchrotron facilities. The next step will consist in its integration into a user-friendly graphical front-end.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation and Control of Hamiltonian Chaos in Wave-particle Interaction

Wave-particle interactions are central in plasma physics. The paradigm beam-plasma system can be advantageously replaced by a traveling wave tube (TWT) to allow their study in a much less noisy environment. This led to detailed analysis of the self-consistent interaction between unstable waves and an either cold or warm electron beam. More recently a test cold beam has been used to observe its interaction with externally excited wave(s). This allowed observing the main features of Hamiltonian chaos and testing a new method to efficiently channel chaotic transport in phase space. To simulate accurately and efficiently the particle dynamics in the TWT and other 1D particle-wave systems, a new symplectic, symmetric, second order numerical algorithm is developed, using particle position as the independent variable, with a fixed spatial step.This contribution reviews: presentation of the TWT and its connection to plasma physics, resonant interaction of a charged particle in electrostatic waves, observation of particle trapping and transition to chaos, test of control of chaos, and description of the simulation algorithm.The velocity distribution function of the electron beam is recorded with a trochoidal energy analyzer at the output of the TWT. An arbitrary waveform generator is used to launch a prescribed spectrum of waves along the 4m long helix of the TWT. The nonlinear synchronization of particles by a single wave, responsible for Landau damping, is observed. We explore the resonant velocity domain associated with a single wave as well as the transition to large scale chaos when the resonant domains of two waves and their secondary resonances overlap. This transition exhibits a devil's staircase behavior when increasing the excitation level in agreement with numerical simulation.A new strategy for control of chaos by building barriers of transport in phase space as well as its robustness is successfully tested. The underlying concepts extend far beyond the field of electron devices and plasma physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron Irradiation of Conjunctival Lymphoma-Monte Carlo Simulation of the Minute Dose Distribution and Technique Optimization

Purpose: External beam radiotherapy is the only conservative curative approach for Stage I non-Hodgkin lymphomas of the conjunctiva. The target volume is geometrically complex because it includes the eyeball and lid conjunctiva. Furthermore, the target volume is adjacent to radiosensitive structures, including the lens, lacrimal glands, cornea, retina, and papilla. The radiotherapy planning and optimization requires accurate calculation of the dose in these anatomical structures that are much smaller than the structures traditionally considered in radiotherapy. Neither conventional treatment planning systems nor dosimetric measurements can reliably determine the dose distribution in these small irradiated volumes. Methods and Materials: The Monte Carlo simulations of a Varian Clinac 2100 C/D and human eye were performed using the PENELOPE and PENEASYLINAC codes. Dose distributions and dose volume histograms were calculated for the bulbar conjunctiva, cornea, lens, retina, papilla, lacrimal gland, and anterior and posterior hemispheres. Results: The simulated results allow choosing the most adequate treatment setup configuration, which is an electron beam energy of 6 MeV with additional bolus and collimation by a cerrobend block with a central cylindrical hole of 3.0 cm diameter and central cylindrical rod of 1.0 cm diameter. Conclusions: Monte Carlo simulation is a useful method to calculate the minute dose distribution in ocular tissue and to optimize the electron irradiation technique in highly critical structures. Using a voxelized eye phantom based on patient computed tomography images, the dose distribution can be estimated with a standard statistical uncertainty of less than 2.4% in 3 min using a computing cluster with 30 cores, which makes this planning technique clinically relevant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the role of wave-particle interactions in the evolution of solar wind ion distribution functions

We investigate the role of kinetic effects in the solar wind expansion using 1-D numerical hybrid simulations. The analysis of proton distribution functions in the solar wind shows a non-adiabatic evolution and suggests that several kinetic processes are at work during the expansion. From simulation studies wave-particle and wave-wave interactions, as cyclotron heating and non-linear trapping due to parametric instabilities, are found to play an important role on constraining the proton temperature anisotropy and generating secondary velocity beams. We report results from hybrid comoving simulations that self-consistently retain and describe these processes. We find that cyclotron interactions control the evolution of the proton temperature anisotropy with distance providing a perpendicular heating which contrasts the adiabatic cooling caused by the expansion. At the same time ion-acoustic modes driven by parametric effects produce a velocity beam in the proton distribution function. The resulting proton distribution functions are reasonable agreement with those observed in situ.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo investigation of breast intraoperative radiation therapy with metal attenuator plates

In intraoperative electron radiation therapy for breast cancer, attenuation plates are commonly used to protect organs at risk. These plates can be made of different materials, and the correct material (or combination of materials) has to be chosen in order to achieve the desired attenuation, while avoiding excessive backscattered radiation. The Monte Carlo method (BEAMnrcMP and DOSXYZnrcMP) has been used to characterize the electron beam generated by the setup (composed of a nondedicated linac and an applicator), and to simulate the percent depth dose (PDD) for plates of different materials. The beam has been characterized for nominal energies of 9 and 12 MeV. Several differently composed plates have been investigated: it was found, as expected, that the use of a plate presenting to the electron beam a high-Z material (i.e., lead) has to be avoided because of excessive backscatter (up to 52% compared to the PDD without plate). On the other hand, the use of a single low-Z material (i.e., aluminum) in the plate can lead to an insufficient attenuation of the beam. The two-layer plate (6 mm of Al plus 3 mm of Cu) used in S. Chiara Hospital has been found to attenuate the beam almost completely for both considered energies, causing negligible backscatter radiation. The spectrum at various depth and at the tissue-plate interface has also been investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ballistic Focusing of Polyenergetic Protons Driven by Petawatt Laser Pulses

By using a thick (250 {mu}m) target with 350 {mu}m radius of curvature, the intense proton beam driven by a petawatt laser is focused at a distance of {approx}1 mm from the target for all detectable energies up to {approx}25 MeV. The thickness of the foil facilitates beam focusing as it suppresses the dynamic evolution of the beam divergence caused by peaked electron flux distribution at the target rear side. In addition, reduction in inherent beam divergence due to the target thickness relaxes the curvature requirement for short-range focusing. Energy resolved mapping of the proton beam trajectories from mesh radiographs infers the focusing and the data agree with a simple geometrical modeling based on ballistic beam propagation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Collisionless Relaxation in Non-Neutral Plasmas

A theoretical framework is presented which allows us to quantitatively predict the final stationary state achieved by a non-neutral plasma during a process of collisionless relaxation. As a specific application, the theory is used to study relaxation of charged-particle beams. It is shown that a fully matched beam relaxes to the Lynden-Bell distribution. However, when a mismatch is present and the beam oscillates, parametric resonances lead to a core-halo phase separation. The approach developed accounts for both the density and the velocity distributions in the final stationary state.

43 PARTICLE ACCELERATORS↗

Simulation of electrostatic turbulence in the plasma sheet boundary layer with electron currents and bean-shaped ion beams

Plasma data from ISEE-1 show the presence of electron currents as well as energetic ion beams in the plasma sheet boundary layer. Broadband electrostatic noise and low-frequency electromagnetic bursts are detected in the plasma sheet boundary layer, especially in the presence of strong ion flows, currents, and steep spacial gradients in the fluxes of few-keV electrons and ions. Particle simulations have been performed to investigate electrostatic turbulence driven by a cold electron beam and/or ion beams with a bean-shaped velocity distribution. The simulation results show that the counterstreaming ion beams as well as the counterstreaming of the cold electron beam and the ion beam excite ion acoustic waves with a given Doppler-shifted real frequency. However, the effect of the bean-shaped ion velocity distributions reduces the growth rates of ion acoustic instability. The simulation results also show that the slowing down of the ion bean is larger at the larger perpendicular velocity. The wave spectra of the electric fields at some points of the simulations show turbulence generated by growing waves.

Nishikawa, K.-I.↗

Equilibrium and pre-equilibrium processes in the {sup 55}Mn({sup 6}Li,xp) and {sup 57}Fe({alpha},xp) reactions

Spectra of outgoing neutrons and protons from the {sup 6}Li + {sup 55}Mn reaction and protons from the {alpha} + {sup 57}Fe reaction have been measured with beams of 15-MeV {sup 6}Li ions and 30-MeV {alpha} particles. These reactions proceed through the same {sup 61}Ni nucleus at the same excitation energy, thus allowing the difference in reaction mechanisms to be studied. It is shown that spectra from the first reaction measured at backward angles are due to emission from a traditional compound nucleus reaction, in which the intermediate nucleus has reached statistical equilibrium; the spectra from the second reaction contain a significant fraction of pre-equilibrium emission at all angles. Level density parameters of the residual nucleus {sup 60}Co have been obtained from the first reaction. Both emission spectra and angular distributions have been measured for the second reaction. It was found that the pre-equilibrium component exhibits a forward-peaked angular distribution, as expected, but with a steeper slope than predicted and with an unusual slight rise at angles above 120 deg. The backward-angle rise is explained qualitatively by the dominance of the multistep compound mechanism at backward angles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coherent X-ray radiation excited by a diverging relativistic electron beam in a single crystal

We develop a dynamic theory of coherent X-rays generated in a single-crystal wafer by a diverging relativistic electron beam. The dependence of the spectral-angular density of coherent X-ray radiation on the angle of divergence is analyzed for the case when the angular spread can be described by the 2D Gaussian distribution. The theory constructed here makes it possible to analyze coherent radiation for an arbitrary angular distribution of electrons in the beam as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-238: Monte Carlo Estimation of Cerenkov Dose for Photo-Dynamic Radiotherapy

Purpose: Estimation of Cerenkov dose from high-energy megavoltage photon and electron beams in tissue and its impact on the radiosensitization using Protoporphyrine IX (PpIX) for tumor targeting enhancement in radiotherapy. Methods: The GEPTS Monte Carlo code is used to generate dose distributions from 18MV Varian photon beam and generic high-energy (45-MV) photon and (45-MeV) electron beams in a voxel-based tissueequivalent phantom. In addition to calculating the ionization dose, the code scores Cerenkov energy released in the wavelength range 375–425 nm corresponding to the pick of the PpIX absorption spectrum (Fig. 1) using the Frank-Tamm formula. Results: The simulations shows that the produced Cerenkov dose suitable for activating PpIX is 4000 to 5500 times lower than the overall radiation dose for all considered beams (18MV, 45 MV and 45 MeV). These results were contradictory to the recent experimental studies by Axelsson et al. (Med. Phys. 38 (2011) p 4127), where Cerenkov dose was reported to be only two orders of magnitude lower than the radiation dose. Note that our simulation results can be corroborated by a simple model where the Frank and Tamm formula is applied for electrons with 2 MeV/cm stopping power generating Cerenkov photons in the 375–425 nm range and assuming these photons have less than 1mm penetration in tissue. Conclusion: The Cerenkov dose generated by high-energy photon and electron beams may produce minimal clinical effect in comparison with the photon fluence (or dose) commonly used for photo-dynamic therapy. At the present time, it is unclear whether Cerenkov radiation is a significant contributor to the recently observed tumor regression for patients receiving radiotherapy and PpIX versus patients receiving radiotherapy only. The ongoing study will include animal experimentation and investigation of dose rate effects on PpIX response.

60 APPLIED LIFE SCIENCES↗

A diagnosis of intense ion beam by CR-39 detectors analyzing the back scattered particles

A new diagnosis method has been developed utilizing back scattered particles for high energy intense ion beams. The CR-39 detector mounted on the uniform back-scatterer was irradiated with {sup 4}He{sup 2+} ions with an energy 25 MeV/n, which is never recorded as etchable track in CR-39. We found that it is possible to diagnose by analyzing the etch pits on the rear surface of CR-39 that directly contacted on the back-scatterers. It turns out that most of etch pits in the rear surface are made by the backscattered particles by investigating the growth pattern of each etch pit with multi-step etching technique. This method allows simple diagnosis of the ion beam profile and intensity distribution in mixed radiation field such as laser-driven ion acceleration experiments.

43 PARTICLE ACCELERATORS↗

A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments

Treatment plans are usually designed, optimized, and evaluated based on the total 3D dose distribution, motivating a total 3D dose verification. The purpose of this study was to develop a 2D transmission-dosimetry method using an electronic portal imaging device (EPID) into a simple 3D method that provides 3D dose information. In the new method, the dose is reconstructed within the patient volume in multiple planes parallel to the EPID for each gantry angle. By summing the 3D dose grids of all beams, the 3D dose distribution for the total treatment fraction is obtained. The algorithm uses patient contours from the planning CT scan but does not include tissue inhomogeneity corrections. The 3D EPID dosimetry method was tested for IMRT fractions of a prostate, a rectum, and a head-and-neck cancer patient. Planned and in vivo-measured dose distributions were within 2% at the dose prescription point. Within the 50% isodose surface of the prescribed dose, at least 97% of points were in agreement, evaluated with a 3D {gamma} method with criteria of 3% of the prescribed dose and 0.3 cm. Full 3D dose reconstruction on a 0.1x0.1x0.1 cm{sup 3} grid and 3D {gamma} evaluation took less than 15 min for one fraction on a standard PC. The method allows in vivo determination of 3D dose-volume parameters that are common in clinical practice. The authors conclude that their EPID dosimetry method is an accurate and fast tool for in vivo dose verification of IMRT plans in 3D. Their approach is independent of the treatment planning system and provides a practical safety net for radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Detailed characterization of a five-dimensional phase space distribution

We image the five-dimensional phase space distribution of a hadron beam in unprecedented detail. The resolution and dynamic range of the measurement are sufficient to resolve sharp, high-dimensional features in low-density regions of phase space. We develop several visualization techniques, including non-planar slicing, to facilitate the identification and analysis of such features. We use these techniques to examine the transverse dependence of longitudinal hollowing and the longitudinal dependence of transverse hollowing in the distribution. Our results strengthen the claim that low-dimensional projections do not adequately characterize high-dimensional phase space distributions.

Hoover, Austin↗

A laboratory experiment to examine the effect of auroral beams on spacecraft charging in the ionosphere

A 2.54 cm diameter conducting electrically isolated Copper sphere is suspended in a low density (10{sup 4} cm{sup -3}), low temperature (T{sub e} = 0.5 eV) Argon plasma, which mimics a spacecraft in an ionospheric plasma. An electron beam with current density of approximately 10{sup -10} A/cm{sup 2} and beam spot of 10.2 cm diameter, which mimics an auroral electron beam, is fired at the sphere while varying the beam energy from 100 eV to 2 keV. The plasma potential in the sheath around the sphere is measured using an emissive probe as the electron beam energy is varied. To observe the effects of the electron beam, the experimental sheath potential profiles are compared to a model of the plasma potential around a spherically symmetric charge distribution in the absence of electron beams. Comparison between the experimental data and the model shows that the sphere is less negative than the model predicts by up to half a volt for beam energies that produce high secondary electron emission from the surface of the sphere. It is shown that this secondary emission can account for changes in potential of spacecraft in the ionosphere as they pass through auroral beams and thus helps to improve interpretations of ionospheric thermal ion distributions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A method for solution of the Euler-Bernoulli beam equation in flexible-link robotic systems

An efficient numerical method for solving the partial differential equation (PDE) governing the flexible manipulator control dynamics is presented. A finite-dimensional model of the equation is obtained through discretization in both time and space coordinates by using finite-difference approximations to the PDE. An expert program written in the Macsyma symbolic language is utilized in order to embed the boundary conditions into the program, accounting for a mass carried at the tip of the manipulator. The advantages of the proposed algorithm are many, including the ability to (1) include any distributed actuation term in the partial differential equation, (2) provide distributed sensing of the beam displacement, (3) easily modify the boundary conditions through an expert program, and (4) modify the structure for running under a multiprocessor environment.

Tzes, Anthony P.↗