SEARCH · Search NASA
Results for “CASE METHOD”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Dynamic Mode Decomposition for Compressive System Identification
Dynamic mode decomposition has emerged as a leading technique to identify spatiotemporal coherent structures from high-dimensional data, benefiting from a strong connection to nonlinear dynamical systems via the Koopman operator. In this work, we integrate and unify two recent innovations that extend DMD to systems with actuation [Proctor et al., 2016] and systems with heavily subsampled measurements [Brunton et al., 2015]. When combined, these methods yield a novel framework for compressive system identification [code is publicly available at: https://github.com/zhbai/cDMDc]. It is possible to identify a low-order model from limited input-output data and reconstruct the associated full-state dynamic modes with compressed sensing, adding interpretability to the state of the reduced-order model. Moreover, when full-state data is available, it is possible to dramatically accelerate downstream computations by first compressing the data. We demonstrate this unified framework on two model systems, investigating the effects of sensor noise, different types of measurements (e.g., point sensors, Gaussian random projections, etc.), compression ratios, and different choices of actuation (e.g., localized, broadband, etc.). In the first example, we explore this architecture on a test system with known low-rank dynamics and an artificially inflated state dimension. The second example consists of a real-world engineering application given by the fluid flow past a pitching airfoil at low Reynolds number. This example provides a challenging and realistic test-case for the proposed method, and results demonstrate that the dominant coherent structures are well characterized despite actuation and heavily subsampled data.
Extended FFT-based micromechanical formulation to consider general non-periodic boundary conditions
Here, this paper presents a new approach for applying non-periodic boundary conditions in the context of FFT-based methods to solve micromechanical problems in heterogeneous solids. The domain of the original problem is extended to satisfy the periodicity requirements at the boundary of the extended domain. The velocity constraint on the boundary of the original domain is replaced by a corresponding constraint on the velocity gradient in the extended volume, and a two-level augmented Lagrangian method is used to enforce the constraint. The proposed method is implemented as an extension of the large-strain elasto-viscoplastic FFT-based (LS-EVPFFT) model of Zecevic et al. (2022). The proposed method is verified in the cases of fully imposed velocity boundary conditions and mixed velocity/traction-free boundary conditions. The accuracy and convergence of the method are studied next, followed by applications to bending and indentation of polycrystals that illustrate the extended capabilities of the proposed formulation.
SU-E-T-25: A Dosimetric Comparison of Three-Dimension Conformal and Intensity-Modulated Radiation Therapy in Esophageal Cancer
Purpose: dosimetric comparison of 3DCRT and IMRT in 9 esophageal cancer. The aim of this paper is to know which of these two techniques is dosimetrically more favorable dosimetrically at both the CTV coverage and dose obtained in the relevant organs at risk, in this case, lungs and heart, as the spinal cord received in all cases below 45 Gy. Methods: we chose 9 patients from our center (CHN) with the same type of esophageal cancer and in which the prescribed dose was the same, 54 Gy. For these treatments we have used the same fields and the same angles (AP (0 °), OPD (225°–240°) and OPI (125°–135°)).All plans have been implemented using Eclipse (version 11.0) with AAA( Analytical Anisotropic Algorithm )(Version 11.0.31). Results: To analyze the coverage of the CTV, we have evaluated the D99% and found that the average dose received by 99% of CTV with IMRT is 53.8 ± 0.4 Gy (99.6% of the prescribed dose) and the mean value obtained with 3DCRT is 52.3 ± 0.6 Gy (96.8% of the prescribed dose).The last data analyzed was the D2% of PTV, a fact that gives us information on the maximum dose received by our PTV. D2% of the PTV for IMRT planning is 55.4 ± 0.4 Gy (102.6% of the prescribed dose) and with 3DCRT is 56.8 ± 0.7 Gy (105.2% of the prescribed dose).All parameters analyzed at risk organs (V30, V40, V45 and V50 for the case of heart and V5, V10, V15 and V20 for the case of the lungs) provide us irradiated volume percentages lower in IMRT than 3DCRT. Conclusion: IMRT provides a considerable improvement in the coverage of the CTV and the doses to organs at risk.
SU-E-T-642: PTV Is the Voxel-Wise Worst-Case of CTV in Prostate Photon Therapy
Purpose: To examine the adequacy of the planning target volume (PTV) dose distribution as the worst-case representation of clinical target volume (CTV) dose distribution in prostate volumetric-modulated arc therapy (VMAT) plans. Methods: Ten intact prostate cancer cases treated by VMAT at our institution were randomly selected. Isocenter was shifted in the three cardinal directions by a displacement equal to the PTV expansion on the CTV (±3 mm) for a total of six shifted plans per original plan. Rotationally-perturbed plans were generated with a couch rotation of ±1° to simulate patient yaw. The eight perturbed dose distributions were recalculated in the treatment planning system using the same, fixed fluence map as the original plan. The voxel-wise worst-case CTV dose distribution was constructed from the minimum value per voxel from the eight perturbed doses. The resulting dose volume histograms (DVH) were evaluated for statistical correlation between the worst-case CTV and nominal PTV dose distributions based on D95% by Wilcoxon signed-rank test with significance level p ≤ 0.05. Results: Inspection demonstrates the PTV DVH in the nominal dose distribution is bounded by the CTV DVH in the worst-case dose distribution. Comparison of D95% for the two dose distributions by Wilcoxon signed-rank test gives p = 0.131. Therefore the null hypothesis cannot be rejected since the difference in median values is not statistically significant. Conclusion: The assumption that the nominal dose distribution for PTV represents the worst-case dose distribution for CTV appears valid for the ten plans under examination. Although the worst-case dose distribution is unphysical since the dose per voxel is chosen independently, it serves as a lower bound for the possible CTV coverage. Furthermore, this is consistent with the unphysical nature of the PTV. Minor discrepancies between the two dose distributions are expected since the dose cloud is not strictly static. Funding Support: NIH/NCI K25CA168984, Eagles Cancer Research Career Development, The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, Mayo ASU Seed Grant, and The Kemper Marley Foundation.
A Frequency-Domain-Based Algorithm for Detecting Microseismicity Using Dense Surface Seismic Arrays
We propose a new frequency-domain-based algorithm for detecting small-magnitude seismic events using dense surface seismic arrays. Our proposed method takes advantage of the high energy carried by S waves, and approximate known source locations, which are used to rotate the horizontal components to obtain the maximum amplitude. By surrounding the known source area with surface geophones, we achieve a favorable geometry for locating the detected seismic events with the backprojection method. To test our new detection method, we used a dense circular array, consisting of 151 5 Hz three-component geophones, over a 5 km aperture that was in operation at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) in southcentral Utah. We apply the new detection method during a small-scale test injection phase at FORGE, and during an aftershock sequence of an Mw 4.1 earthquake located ~30 km north of the geophone array, within the Black Rock volcanic field. We are able to detect and locate microseismic events (Mw<0) during injections, despite the high level of anthropogenic activity, and several aftershocks that are missing from the regional catalog. By comparing our method with known algorithms that operate both in the time and frequency domain, we show that our proposed method performs better in the case of the FORGE injection monitoring, and equally well for the off-array aftershock sequence. Our new method has the potential to improve microseismic event detections even in extremely noisy environments, and the proposed location scheme serves as a direct discriminant between true and false detections.
A general method for calculating three-dimensional compressible laminar and turbulent boundary layers on arbitrary wings
The method described utilizes a nonorthogonal coordinate system for boundary-layer calculations. It includes a geometry program that represents the wing analytically, and a velocity program that computes the external velocity components from a given experimental pressure distribution when the external velocity distribution is not computed theoretically. The boundary layer method is general, however, and can also be used for an external velocity distribution computed theoretically. Several test cases were computed by this method and the results were checked with other numerical calculations and with experiments when available. A typical computation time (CPU) on an IBM 370/165 computer for one surface of a wing which roughly consist of 30 spanwise stations and 25 streamwise stations, with 30 points across the boundary layer is less than 30 seconds for an incompressible flow and a little more for a compressible flow.
FY17 Status Report on the Initial EPP Finite Element Analysis of Grade 91 Steel
This report describes a modification to the elastic-perfectly plastic (EPP) strain limits design method to account for cyclic softening in Gr. 91 steel. The report demonstrates that the unmodified EPP strain limits method described in current ASME code case is not conservative for materials with substantial cyclic softening behavior like Gr. 91 steel. However, the EPP strain limits method can be modified to be conservative for softening materials by using softened isochronous stress-strain curves in place of the standard curves developed from unsoftened creep experiments. The report provides softened curves derived from inelastic material simulations and factors describing the transformation of unsoftened curves to a softened state. Furthermore, the report outlines a method for deriving these factors directly from creep/fatigue tests. If the material softening saturates the proposed EPP strain limits method can be further simplified, providing a methodology based on temperature-dependent softening factors that could be implemented in an ASME code case allowing the use of the EPP strain limits method with Gr. 91. Finally, the report demonstrates the conservatism of the modified method when applied to inelastic simulation results and two bar experiments.
Pairing in Cold Atoms and other Applications for Quantum Monte Carlo methods
We discuss the importance of the fermion nodes for the quantum Monte Carlo (QMC) methods and find two cases of the exact nodes. We describe the structure of the gen- eralized pairing wave functions in Pfaffian antisymmetric form and demonstrate their equivalency with certain class of configuration interaction wave functions. We present the QMC calculations of a model fermion system at unitary limit. We find the system to have the energy of E = 0.425Efree and the condensate fraction of = 0.48. Further we also perform the QMC calculations of the potential energy surface and the electric dipole moment along that surface of the LiSr molecule. We estimate the vibrationally averaged dipole moment to be D =0 = 0.4(2).
A nonparametric method for producing isolines of bivariate exceedance probabilities
We present a method for drawing isolines indicating regions of equal joint exceedance probability for bivariate data. The method relies on bivariate regular variation, a dependence framework widely used for extremes. The method we utilize for characterizing dependence in the tail is largely nonparametric. The extremes framework enables drawing isolines corresponding to very low exceedance probabilities and may even lie beyond the range of the data; such cases would be problematic for standard nonparametric methods. Furthermore, we extend this method to the case of asymptotic independence and propose a procedure which smooths the transition from hidden regular variation in the interior to the first-order behavior on the axes. We propose a diagnostic plot for assessing the isoline estimate and choice of smoothing, and a bootstrap procedure to visually assess uncertainty.
Estimating the Need for Radiotherapy for Patients With Prostate, Breast, and Lung Cancers: Verification of Model Estimates of Need With Radiotherapy Utilization Data From British Columbia
Purpose: Estimates of the need for radiotherapy (RT) using different methods (criterion based benchmarking [CBB]and the Canadian [C-EBEST]and Australian [A-EBEST]epidemiologically based estimates) exist for various cancer sites. We compared these model estimates to actual RT rates for lung, breast, and prostate cancers in British Columbia (BC). Methods and Materials: All cases of lung, breast, and prostate cancers in BC from 1997 to 2004 and all patients receiving RT within 1 year (RT{sub 1Y}) and within 5 years (RT{sub 5Y}) of diagnosis were identified. The RT{sub 1Y} and RT{sub 5Y} proportions in health regions with a cancer center for the most recent year were then calculated. RT rates were compared with CBB and EBEST estimates of RT needs. Variation was assessed by time and region. Results: The RT{sub 1Y} in regions with a cancer center for lung, breast, and prostate cancers were 51%, 58%, and 33% compared with 45%, 57%, and 32% for C-EBEST and 41%, 61%, and 37% for CBB models. The RT{sub 5Y} rates in regions with a cancer center for lung, breast, and prostate cancers were 59%, 61%, and 40% compared with 61%, 66%, and 61% for C-EBEST and 75%, 83%, and 60% for A-EBEST models. The RT{sub 1Y} rates increased for breast and prostate cancers. Conclusions: C-EBEST and CBB model estimates are closer to the actual RT rates than the A-EBEST estimates. Application of these model estimates by health care decision makers should be undertaken with an understanding of the methods used and the assumptions on which they were based.
A direct Vlasov code to study the non-stationary current collection by a cylindrical Langmuir probe
The time-dependent current collection by a cylindrical Langmuir probe, whose bias is suddenly changed from zero to a positive or negative finite value, is studied with a novel direct Vlasov code. The numerical algorithm is based on finite-difference formulas to approximate spatial and velocity derivatives and the time integration is carried out with an explicit Runge-Kutta method, or in the case of probe radius small compared with the Debye length, by using the unconditionally stable backward Euler scheme. Both electrons and ions are treated kinetically by the code, which implements initial and boundary conditions that are consistent with the presence of the probe. Within the considered parameter range, the plasma sheath around the probe exhibited an overshoot and it later recovered a steady state. Phase space diagrams of the particle trajectories revealed the presence of a trapped population of particles. The dependence of this population as a function of the probe radius is presented as well as a comparison with the stationary theory. The performance of the code and a comparison with previously used particle-in-cell algorithms are discussed.
SU-G-JeP1-01: A Combination of Real Time Electromagnetic Localization and Tracking with Cone Beam Computed Tomography in Stereotactic Radiosurgery for Brain Tumors
Purpose: 1. online verification of patient position during treatment using calypso electromagnetic localization and tracking system. 2. Verification and comparison of positional accuracy between cone beam computed tomography and calypso system. 3. Presenting the advantage of continuation localization in Stereotactic radiosurgery treatments. Methods: Ten brain tumor cases were taken for this study. Patients with head mask were under gone Computed Tomography (CT). Before scanning, mask was cut on the fore head area to keep surface beacons on the skin. Slice thickness of 0.65 mm were taken for this study. x, y, z coordinates of these beacons in TPS were entered into tracking station. Varian True Beam accelerator, equipped with On Board Imager was used to take Cone beam Computed Tomography (CBCT) to localize the patient. Simultaneously Surface beacons were used to localize and track the patient throughout the treatment. The localization values were compared in both systems. For localization CBCT considered as reference. Tracking was done throughout the treatment using Calypso tracking system using electromagnetic array. This array was in tracking position during imaging and treatment. Flattening Filter free beams of 6MV photons along with Volumetric Modulated Arc Therapy was used for the treatment. The patient movement was observed throughout the treatment ranging from 2 min to 4 min. Results: The average variation observed between calypso system and CBCT localization was less than 0.5 mm. These variations were due to manual errors while keeping beacon on the patient. Less than 0.05 cm intra-fraction motion was observed throughout the treatment with the help of continuous tracking. Conclusion: Calypso target localization system is one of the finest tools to perform radiosurgery in combination with CBCT. This non radiographic method of tracking is a real beneficial method to treat patients confidently while observing real-time motion information of the patient.
Likelihood-based molecular-replacement solution for a highly pathological crystal with tetartohedral twinning and sevenfold translational noncrystallographic symmetry
With the implementation of a molecular-replacement likelihood target that accounts for translational noncrystallographic symmetry, it became possible to solve the crystal structure of a protein with seven tetrameric assemblies arrayed translationally along the c axis. The new algorithm found 56 protein molecules in reduced symmetry (P1), which was used to resolve space-group ambiguity caused by severe twinning. Translational noncrystallographic symmetry (tNCS) is a pathology of protein crystals in which multiple copies of a molecule or assembly are found in similar orientations. Structure solution is problematic because this breaks the assumptions used in current likelihood-based methods. To cope with such cases, new likelihood approaches have been developed and implemented in Phaser to account for the statistical effects of tNCS in molecular replacement. Using these new approaches, it was possible to solve the crystal structure of a protein exhibiting an extreme form of this pathology with seven tetrameric assemblies arrayed along the c axis. To resolve space-group ambiguities caused by tetartohedral twinning, the structure was initially solved by placing 56 copies of the monomer in space group P1 and using the symmetry of the solution to define the true space group, C2. The resulting structure of Hyp-1, a pathogenesis-related class 10 (PR-10) protein from the medicinal herb St John’s wort, reveals the binding modes of the fluorescent probe 8-anilino-1-naphthalene sulfonate (ANS), providing insight into the function of the protein in binding or storing hydrophobic ligands.
Analysis of the Spectral Stability of the Generalized Runge–Kutta Methods Applied to Initial-Boundary-Value Problems for Equations of the Parabolic Type. II. Implicit Methods
We consider specific realizations of different implicit generalized Runge–Kutta methods as applied to the numerical integration with respect to time of initial-boundary-value problems for the second-order parabolic equations and investigate their spectral stability. It is shown that all implicit generalized Runge–Kutta methods are unconditionally spectrally stable but some of them have the conditional property of monotonicity of the numerical solution with respect to time. The functions of spectral stability of the implicit generalized Runge–Kutta methods are rational. We compare the analytic solution of the nonstationary one-dimensional problem of heat conduction with the numerical solutions of this problem obtained by different implicit generalized Runge–Kutta methods. It is shown that, in this case, the application of the one-stage Radau methods with subsequent discretization of the problem with respect to the space variable leads to the classical forward finite difference scheme (Laasonen scheme), whereas the use of the one-stage Gauss–Legendre method leads to a six-point symmetric scheme (Crank–Nicolson scheme). It is shown that diagonally implicit generalized Nørsett and Burrage methods are realized in almost the same way as the one-stage Radau and Gauss–Legendre methods but their accuracy in the time step is 10–1000 times higher. On the basis of comparison of the numerical and analytic solutions, we conclude that, in order to get practically suitable numerical solutions without any restrictions on the time step, it is reasonable to use one- and three-stage generalized Radau methods or two- and four-stage Lobatto IIIC methods. All other explicit and implicit generalized Runge–Kutta methods require certain restrictions imposed on the time step.
Modeling occupancy distribution in large spaces with multi-feature classification algorithm
We present that occupancy information enables robust and flexible control of heating, ventilation, and air-conditioning (HVAC) systems in buildings. In large spaces, multiple HVAC terminals are typically installed to provide cooperative services for different thermal zones, and the occupancy information determines the cooperation among terminals. However, a person count at room-level does not adequately optimize HVAC system operation due to the movement of occupants within the room that creates uneven load distribution. Without accurate knowledge of the occupants’ spatial distribution, the uneven distribution of occupants often results in under-cooling/heating or over-cooling/heating in some thermal zones. Therefore, the lack of high-resolution occupancy distribution is often perceived as a bottleneck for future improvements to HVAC operation efficiency. To fill this gap, this study proposes a multi-feature k-Nearest-Neighbors (k-NN) classification algorithm to extract occupancy distribution through reliable, low-cost Bluetooth Low Energy (BLE) networks. An on-site experiment was conducted in a typical office of an institutional building to demonstrate the proposed methods, and the experiment outcomes of three case studies were examined to validate detection accuracy. One method based on City Block Distance (CBD) was used to measure the distance between detected occupancy distribution and ground truth and assess the results of occupancy distribution. Finally, the results show the accuracy when CBD = 1 is over 71.4% and the accuracy when CBD = 2 can reach up to 92.9%.
Bootstrap-determined p values in lattice QCD
We present a general method to determine the probability that stochastic Monte Carlo data, in particular those generated in a lattice QCD calculation, would have been obtained were that data drawn from the distribution predicted by a given theoretical hypothesis. Such a probability, or p -value, is often used as an important heuristic measure of the validity of that hypothesis. The proposed method offers the benefit that it remains usable in cases where the standard Hotelling T 2 methods based on the conventional χ 2 statistic do not apply, such as for uncorrelated fits. Specifically, we analyze q 2 , defined as the correlated χ 2 statistic obtained using an arbitrary covariance matrix estimator, and show how to use the bootstrap as a data-driven method to determine the expected distribution of q 2 for a given hypothesis with minimal assumptions. This distribution can then be used to determine the p -value for a fit to the data. We also describe a bootstrap approach for quantifying the impact upon this p -value of estimating population parameters from a single ensemble of N samples. The overall method is accurate up to a 1 / N bias which we do not attempt to quantify. Published by the American Physical Society 2025
Cone beam x-ray luminescence computed tomography: A feasibility study
Purpose: The appearance of x-ray luminescence computed tomography (XLCT) opens new possibilities to perform molecular imaging by x ray. In the previous XLCT system, the sample was irradiated by a sequence of narrow x-ray beams and the x-ray luminescence was measured by a highly sensitive charge coupled device (CCD) camera. This resulted in a relatively long sampling time and relatively low utilization of the x-ray beam. In this paper, a novel cone beam x-ray luminescence computed tomography strategy is proposed, which can fully utilize the x-ray dose and shorten the scanning time. The imaging model and reconstruction method are described. The validity of the imaging strategy has been studied in this paper. Methods: In the cone beam XLCT system, the cone beam x ray was adopted to illuminate the sample and a highly sensitive CCD camera was utilized to acquire luminescent photons emitted from the sample. Photons scattering in biological tissues makes it an ill-posed problem to reconstruct the 3D distribution of the x-ray luminescent sample in the cone beam XLCT. In order to overcome this issue, the authors used the diffusion approximation model to describe the photon propagation in tissues, and employed the sparse regularization method for reconstruction. An incomplete variables truncated conjugate gradient method and permissible region strategy were used for reconstruction. Meanwhile, traditional x-ray CT imaging could also be performed in this system. The x-ray attenuation effect has been considered in their imaging model, which is helpful in improving the reconstruction accuracy. Results: First, simulation experiments with cylinder phantoms were carried out to illustrate the validity of the proposed compensated method. The experimental results showed that the location error of the compensated algorithm was smaller than that of the uncompensated method. The permissible region strategy was applied and reduced the reconstruction error to less than 2 mm. The robustness and stability were then evaluated from different view numbers, different regularization parameters, different measurement noise levels, and optical parameters mismatch. The reconstruction results showed that the settings had a small effect on the reconstruction. The nonhomogeneous phantom simulation was also carried out to simulate a more complex experimental situation and evaluated their proposed method. Second, the physical cylinder phantom experiments further showed similar results in their prototype XLCT system. With the discussion of the above experiments, it was shown that the proposed method is feasible to the general case and actual experiments. Conclusions: Utilizing numerical simulation and physical experiments, the authors demonstrated the validity of the new cone beam XLCT method. Furthermore, compared with the previous narrow beam XLCT, the cone beam XLCT could more fully utilize the x-ray dose and the scanning time would be shortened greatly. The study of both simulation experiments and physical phantom experiments indicated that the proposed method was feasible to the general case and actual experiments.