Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Validation of full-wave simulations for mode conversion of waves in the ion cyclotron range of frequencies with phase contrast imaging in Alcator C-Mod

Mode conversion of fast waves in the ion cyclotron range of frequencies (ICRF) is known to result in current drive and flow drive under optimised conditions, which may be utilized to control plasma profiles and improve fusion plasma performance. To describe these processes accurately in a realistic toroidal geometry, numerical simulations are essential. Quantitative comparison of these simulations and the actual experimental measurements is important to validate their predictions and to evaluate their limitations. The phase contrast imaging (PCI) diagnostic has been used to directly detect the ICRF waves in the Alcator C-Mod tokamak. The measurements have been compared with full-wave simulations through a synthetic diagnostic technique. Recently, the frequency response of the PCI detector array on Alcator C-Mod was recalibrated, which greatly improved the comparison between the measurements and the simulations. In this study, mode converted waves for D-{sup 3}He and D-H plasmas with various ion species compositions were re-analyzed with the new calibration. For the minority heating cases, self-consistent electric fields and a minority ion distribution function were simulated by iterating a full-wave code and a Fokker-Planck code. The simulated mode converted wave intensity was in quite reasonable agreement with the measurements close to the antenna, but discrepancies remain for comparison at larger distances.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Summary of the Graduate Mentoring Assistance Program for PNNL PNNL.12.006 (April 2012 – May 31, 2013)

Summary of Students and Projects: Sarah Bender: The possible improvement of the Multi-Isotope Process (MIP) Monitor by the addition of Compton suppression is investigated for this study. The Compton continuum from the dominant 661.7 keV Cs-137 fission product peak obscures lower energy lines which could be used for spectral and multivariate analysis. A novel Compton suppression system which uses fast, room-temperature materials will be developed using simulation. As opposed to the standard high purity germanium (HPGe) detector suppressed using a thallium-doped sodium iodide (NaI(Tl)) guard detector array, cerium-doped lanthanum bromide (LaBr3) will be used as the primary spectroscopic detector. For Sarah’s Master’s degree, she constructed and validated the unsuppressed detector response of the Pennsylvania State University (PSU)-Compton suppression system. For Sarah’s PhD, she is completing that simulation by including the suppressed operation which will be validated with spent fuel samples. She is also going to use the validation of suppressed operation to predict the detector response of a LaBr3 based Compton suppression system. Richard Clark: Richard Clark completed his study this FY of a new technique known as Intrinsic Dosimetry. Intrinsic Dosimetry is the method of measuring total absorbed dose received by the walls of a container holding radioactive material. By considering the total absorbed dose received by a container in tandem with the physical characteristics of the radioactive material housed within that container, this method has the potential to provide enhanced pathway information regarding the history of the container and its radioactive contents. The latest in a series of experiments designed to validate and demonstrate this newly developed tool are reported. Kenneth Dayman: The MIP Monitor is an online, non-destructive approach to process monitoring in a nuclear fuel reprocessing facility using gamma spectra taken of process streams and multivariate data analysis to detect anomalies in operation. Last year, Mr. Dayman investigated methods to classify spent nuclear fuel according to both reactor type and burn up based on the constituent nuclide activities, which may be used to more accurately calibrate other models in an analysis scheme in order to improve the accuracy and precision of predictions. He is currently writing up his results for publication and has transitioned to another project with Dr. Derrick Haas at PNNL.

Schwantes, Jon M.↗

Dual-Chamber/Dual-Anode Proportional Counter Incorporating an Intervening Thin-Foil Solid Neutron Converter

A dual-chamber/dual-anode gas proportional counter utilizing thin solid 6LiF or 10B neutron converters coated on a 2-micon-thick Mylar film that is positioned between the two counter chambers and anodes has been designed, fabricated, and tested using a variety of fill gases including naturally abundant helium. In this device, neutron conversion products emitted from both sides of the coated converter foil are detected rather than having half of the products absorbed in the wall of a conventional tube type counter where the solid neutron converter is deposited on the tube wall. Geant4-based radiation transport calculations were used to determine the optimum neutron converter coating thickness for both isotopes. Solution methods for applying these optimized-thickness coatings on a Mylar film were developed that were carried out at room temperature without any specialized equipment and that can be adapted to standard coating methods such as silk screen or ink jet printing. The performance characteristics of the dual-chamber/dual-anode neutron detector were determined for both types of isotopically enriched converters. The experimental performance of the 6LiF converter-based detector was described well by modeling results from Geant4. Additional modeling studies of multiple-foil/multiple-chamber/anode configurations addressed the basic issue of the relatively longer absorption range of neutrons versus the shorter range of the conversion products for 6LiF and 10B. Combined with the experimental results, these simulations indicate that a high-performance neutron detector can be realized in a single device through the application of these multiple-foil/solid converter, multiple-chamber detector concepts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence for the Scissors Mode in {sup 160}Tb from the Two-Step Gamma Cascades Measurement

Spectra of two-step {gamma} cascades (TSCs) following the neutron capture in {sup 159}Tb were measured by the sum-coincidence technique with a two-HPGe-detector facility [1] installed at a pure sub-thermal neutron beam of the 15 MW light-water research reactor at Rez near Prague. In order to obtain information about the quantities governing the {gamma} decay of {sup 160}Tb levels--the photon strength functions (PSFs) and the level density (LD)--experimental TSC spectra were compared with the output of simulations of the {gamma} cascade decay based on the validity of extreme statistical model. These simulations were performed with the aid of the DICEBOX algorithm [2] assuming various combinations of the PSFs and LD. The results obtained lead to an inescapable conclusion that the Scissors Mode (SM) plays a crucial role in the cascade {gamma} decay of the product nucleus {sup 160}Tb. This finding represents the first evidence for the existence of the SM in an odd-odd nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Image-based spectral distortion correction for photon-counting x-ray detectors

Purpose: To investigate the feasibility of using an image-based method to correct for distortions induced by various artifacts in the x-ray spectrum recorded with photon-counting detectors for their application in breast computed tomography (CT). Methods: The polyenergetic incident spectrum was simulated with the tungsten anode spectral model using the interpolating polynomials (TASMIP) code and carefully calibrated to match the x-ray tube in this study. Experiments were performed on a Cadmium-Zinc-Telluride (CZT) photon-counting detector with five energy thresholds. Energy bins were adjusted to evenly distribute the recorded counts above the noise floor. BR12 phantoms of various thicknesses were used for calibration. A nonlinear function was selected to fit the count correlation between the simulated and the measured spectra in the calibration process. To evaluate the proposed spectral distortion correction method, an empirical fitting derived from the calibration process was applied on the raw images recorded for polymethyl methacrylate (PMMA) phantoms of 8.7, 48.8, and 100.0 mm. Both the corrected counts and the effective attenuation coefficient were compared to the simulated values for each of the five energy bins. The feasibility of applying the proposed method to quantitative material decomposition was tested using a dual-energy imaging technique with a three-material phantom that consisted of water, lipid, and protein. The performance of the spectral distortion correction method was quantified using the relative root-mean-square (RMS) error with respect to the expected values from simulations or areal analysis of the decomposition phantom. Results: The implementation of the proposed method reduced the relative RMS error of the output counts in the five energy bins with respect to the simulated incident counts from 23.0%, 33.0%, and 54.0% to 1.2%, 1.8%, and 7.7% for 8.7, 48.8, and 100.0 mm PMMA phantoms, respectively. The accuracy of the effective attenuation coefficient of PMMA estimate was also improved with the proposed spectral distortion correction. Finally, the relative RMS error of water, lipid, and protein decompositions in dual-energy imaging was significantly reduced from 53.4% to 6.8% after correction was applied. Conclusions: The study demonstrated that dramatic distortions in the recorded raw image yielded from a photon-counting detector could be expected, which presents great challenges for applying the quantitative material decomposition method in spectral CT. The proposed semi-empirical correction method can effectively reduce these errors caused by various artifacts, including pulse pileup and charge sharing effects. Furthermore, rather than detector-specific simulation packages, the method requires a relatively simple calibration process and knowledge about the incident spectrum. Therefore, it may be used as a generalized procedure for the spectral distortion correction of different photon-counting detectors in clinical breast CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alpha Coincidence Spectroscopy studied with GEANT4

Abstract The high-energy side of peaks in alpha spectra, e.g. 241Am, as measured with a silicon detector has structure caused mainly by alpha-conversion electron and to some extent alphagamma coincidences. We compare GEANT4 simulation results to 241Am alpha spectroscopy measurements with a passivated implanted planar silicon detector. A large discrepancy between the measurements and simulations suggest that the GEANT4 photon evaporation database for 237Np (daughter of 241Am decay) does not accurately describe the conversion electron spectrum and therefore was found to have large discrepancies with experimental measurements. We describe how to improve the agreement between GEANT4 and alpha spectroscopy for actinides of interest by including experimental measurements of conversion electron spectroscopy into the photon evaporation database.

Dion, Michael P.↗

Modeling light signals using data from the first pulsed neutron source program at the DUNE vertical drift ColdBox test facility at the CERN Neutrino Platform

In this paper, we present a first quantitative test of detected light signals produced in a pulsed neutron source run in a small vertical drift LArTPC at the CERN Neutrino Platform ColdBox test facility. The ColdBox cryostat, detectors, neutron sources, and particle interactions are modeled and simulated using Fluka. We demonstrate the ability to identify the contribution from neutron interactions using X-ARAPUCA photodetectors, and show first comparisons of data to simulation, which indicate reasonable agreement. A time constant is also fitted from the neutron-beam-off light signal spectrum and found consistent between data and simulation. Several important systematic effects are discussed and serve as guides for future runs at larger LArTPCs.

Detector modelling and simulations I (interaction ↗

UCSB High Energy Physics Detector R&D Final Technical Report

The R&D efforts of the UCSB Detector R&D program in the 2015--2017 period are reported. These were to develop a liquid scintillator based detector to be used for characterizing radioactive impurities in samples for rapid and effective screening of low background materials for direct dark matter detection experiments; complete engineering and simulation work investigating the feasibility of constructing large detectors in salt caverns; and provide engineering innovation for development of new ideas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Orbiter global positioning system design and Ku-band problem investigations, exhibit B, revision 1

The shuttle Ku-band Costas loop lock detector output signal appears to vary about the lock detection threshold (the lock detect flag is on and off) shortly after the carrier acquisition starts. Real time computer simulation was performed to obtain the signal output from the low pass filter of the lock detector. Based on this simulation, it appears that the oscillation of in-lock and out-lock is related to tracking process and is not caused by the sweep acquisition algorithm.

Lindsey, W. C.↗

High-resolution Thomson parabola for ion analysis

A new, versatile Thomson parabola ion energy (TPIE) analyzer has been designed, constructed, and used at the OMEGA-EP facility. Laser-accelerated multi-MeV ions from hemispherical C targets are transmitted through a W pinhole into a multi-kG magnetic field and subsequently through a parallel electric field of up to 25 kV/cm. The ion drift region has a user-selected length of 10, 50, or 80 cm. With the highest fields, 400-MeV C{sup 6+} and C{sup 5+} may be resolved. TPIE is ten-inch manipulator (TIM)-mounted at OMEGA-EP and can be used opposite either of the EP ps beams. The instrument runs on pressure-interlocked 15-Vdc power available in EP TIM carts. Flux control derives from the insertion depth into the target chamber and the user-selected pinhole dimensions. The detector consists of CR39 backed by an image plate. A fully relativistic simulation code for calculating ion trajectories was employed for design optimization. Excellent agreement of code predictions with the actual ion positions on the detectors is observed. Through pit counting of carbon-ion tracks in CR39, it is shown that conversion efficiency of laser light to energetic carbon ions exceeds {approx}5% for these targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Background Model for the Majorana Demonstrator

The Majorana Collaboration is constructing a prototype system containing 40 kg of HPGe detectors to demonstrate the feasibility and potential of a future tonne-scale experiment to search for neutrinoless double-beta (0v BB) decay in 76Ge. In view of the requirement that the next generation of tonne-scale Ge-based 0vBB-decay experiment be capable of probing the neutrino mass scale in the inverted-hierarchy region, a major goal of theMajorana Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 cnt/(ROI-t-y) in the 4 keV region of interest around the Q-value at 2039 keV. This goal is pursued through a combination of a significant reduction of radioactive impurities in construction materials with analytical methods for background rejection, for example using powerful pulse shape analysis techniques profiting from the p-type point contact HPGe detectors technology. The effectiveness of these methods is assessed using Geant4 simulations of the different background components whose purity levels are constrained from radioassay measurements.

Cuesta, C.↗

A new MCNPX PTRAC coincidence capture file capability: a tool for neutron detector design

The existing Monte Carlo N-Particle (MCNPX) particle tracking (PTRAC) coincidence capture file allows a full list of neutron capture events to be recorded in any simulated detection medium. The originating event history number (e.g. spontaneous fission events), capture time, location and source particle number are tracked and output to file for post-processing. We have developed a new MCNPX PTRAC coincidence capture file capability to aid detector design studies. New features include the ability to track the nuclides that emitted the detected neutrons as well as induced fission chains in mixed samples before detection (both generation number and nuclide that underwent induced fission). Here, the power of this tool is demonstrated using a detector design developed for the non-destructive assay (NDA) of spent nuclear fuel. Individual capture time distributions have been generated for neutrons originating from Curium-244 source spontaneous fission events and induced fission events in fissile nuclides of interest: namely Plutonium-239, Plutonium-241, and Uranium-235. Through this capability, a full picture for the attribution of neutron capture events in the detector can be simulated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Downlink Receiver Algorithms for Deep Space Optical Communications

The goal of the Deep Space Optical Communications project at the Jet Propulsion Laboratory is to demonstrate laser communication links at ranges out to approximately 3 AU. In this paper, we discuss a downlink receiver concept capable of demodulating optical pulse-position modulated (PPM) waveforms with data rates varying from approximately 50 kbps up to 265 Mbps, using a range of PPM orders, slot widths, and code rates. The receiver operates on recorded timestamps corresponding to the times-of-arrival of photons detected by a photon-counting detector array followed by a commercial time-tagger. Algorithms are presented for slot, symbol, and frame synchronization as well as parameter estimation. Estimates of link performance are evaluated through Monte- Carlo simulation for an optical channel that includes optical losses, detector blocking, signal clock dynamics, and pointing-induced downlink fades. Based upon these simulation results, it is expected that link closure may be achieved with at least 3 dB of margin under a variety of relevant conditions.

Tkacenko, Andre↗

A new NCNPX PTRAC coincidence capture file capability: a tool for neutron detector design

The existing Monte Carlo N-Particle (MCNPX) particle tracking (PTRAC) coincidence capture file allows a full list of neutron capture events to be recorded in any simulated detection medium. The originating event history number (e.g. spontaneous fission events), capture time, location and source particle number are tracked and output to file for post-processing. We have developed a new MCNPX PTRAC coincidence capture file capability to aid detector design studies. New features include the ability to track the nuclides that emitted the detected neutrons as well as induced fission chains in mixed samples before detection (both generation number and nuclide that underwent induced fission). Here, the power of this tool is demonstrated using a detector design developed for the non-destructive assay (NDA) of spent nuclear fuel. Individual capture time distributions have been generated for neutrons originating from Curium-244 source spontaneous fission events and induced fission events in fissile nuclides of interest: namely Plutonium-239, Plutonium-241, and Uranium-235. Through this capability, a full picture for the attribution of neutron capture events in the detector can be simulated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A New Signal Model for Axion Cavity Searches from N -body Simulations

Signal estimates for direct axion dark matter (DM) searches have used the isothermal sphere halo model for the last several decades. While insightful, the isothermal model does not capture effects from a halo’s infall history nor the influence of baryonic matter, which has been shown to significantly influence a halo’s inner structure. The high resolution of cavity axion detectors can make use of modern cosmological structure-formation simulations, which begin from realistic initial conditions, incorporate a wide range of baryonic physics, and are capable of resolving detailed structure. This work uses a state-of-the-art cosmological N -body+Smoothed-Particle Hydrodynamics simulation to develop an improved signal model for axion cavity searches. Signal shapes from a class of galaxies encompassing the Milky Way are found to depart significantly from the isothermal sphere. A new signal model for axion detectors is proposed and projected sensitivity bounds on the Axion DM eXperiment (ADMX) data are presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Designing observables for measurements with deep learning

Many analyses in particle and nuclear physics use simulations to infer fundamental, effective, or phenomenological parameters of the underlying physics models. When the inference is performed with unfolded cross sections, the observables are designed using physics intuition and heuristics. We propose to design targeted observables with machine learning. Unfolded, differential cross sections in a neural network output contain the most information about parameters of interest and can be well-measured by construction. The networks are trained using a custom loss function that rewards outputs that are sensitive to the parameter(s) of interest while simultaneously penalizing outputs that are different between particle-level and detector-level (to minimize detector distortions). We demonstrate this idea in simulation using two physics models for inclusive measurements in deep inelastic scattering. We find that the new approach is more sensitive than classical observables at distinguishing the two models and also has a reduced unfolding uncertainty due to the reduced detector distortions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Methods for Quantitative Interpretation of Retarding Field Analyzer Data

Over the course of the CesrTA program at Cornell, over 30 Retarding Field Analyzers (RFAs) have been installed in the CESR storage ring, and a great deal of data has been taken with them. These devices measure the local electron cloud density and energy distribution, and can be used to evaluate the efficacy of different cloud mitigation techniques. Obtaining a quantitative understanding of RFA data requires use of cloud simulation programs, as well as a detailed model of the detector itself. In a drift region, the RFA can be modeled by postprocessing the output of a simulation code, and one can obtain best fit values for important simulation parameters with a chi-square minimization method.

43 PARTICLE ACCELERATORS↗

SU-F-T-287: A Preliminary Study On Patient Specific VMAT Verification Using a Phosphor-Screen Based Geometric QA System (Raven QA)

Purpose: The RavenQA system (LAP Laser, Germany) is a QA device with a phosphor screen detector for performing the QA tasks of TG-142. This study tested if it is feasible to use the system for the patient specific QA of the Volumetric Modulated Arc Therapy (VMAT). Methods: Water equivalent material (5cm) is attached to the front of the detector plate of the RavenQA for dosimetry purpose. Then the plate is attached to the gantry to synchronize the movement between the detector and the gantry. Since the detector moves together with gantry, The ’Reset gantry to 0’ function of the Eclipse planning system (Varian, CA) is used to simulate the measurement situation when calculating dose of the detector plate. The same gantry setup is used when delivering the treatment beam for feasibility test purposes. Cumulative dose is acquired for each arc. The optical scatter component of each captured image from the CCD camera is corrected by deconvolving the 2D spatial invariant optical scatter kernel (OSK). We assume that the OSK is a 2D isotropic point spread function with inverse-squared decrease as a function of radius from the center. Results: Three cases of VMAT plans including head & neck, whole pelvis and abdomen-pelvis are tested. Setup time for measurements was less than 5 minutes. Passing rates of absolute gamma were 99.3, 98.2, 95.9 respectively for 3%/3mm criteria and 96.2, 97.1, 86.4 for 2%/2mm criteria. The abdomen-pelvis field has long treatment fields, 37cm, which are longer than the detector plate (25cm). This plan showed relatively lower passing rate than other plans. Conclusion: An algorithm for IMRT/VMAT verification using the RavenQA has been developed and tested. The model of spatially invariant OSK works well for deconvolution purpose. It is proved that the RavenQA can be used for the patient specific verification of VMAT. This work is funded in part by a Maryland Industrial Partnership Program grant to University of Maryland and to JPLC who owns the Raven technology. John Wong is a co-founder of JPLC.

60 APPLIED LIFE SCIENCES↗