Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distillates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

A Typology of Decision-Making Tasks for Visualization

Despite decision-making being a vital goal of data visualization, little work has been done to differentiate decision-making tasks within the field. While visualization task taxonomies and typologies exist, they often focus on more granular analytical tasks that are too low-level to describe large complex decisions, which can make it difficult to reason about and design decision-support tools. In this paper, we contribute a typology of decision-making tasks that were iteratively refined from a list of design goals distilled from a literature review. Our typology is concise and consists of only three tasks: CHOOSE, ACTIVATE, and CREATE. Although decision types originating in other disciplines exist, we provide definitions for these tasks that are suitable for the visualization community. Our proposed typology offers two benefits. First, the ability to compose and hierarchically organize the tasks enables flexible and clear descriptions of decisions with varying levels of complexities. Second, the typology encourages productive discourse between visualization designers and domain experts by abstracting the intricacies of data, thereby promoting clarity and rigorous analysis of decision-making processes. We demonstrate the benefits of our typology through four case studies, and present an evaluation of the typology from semi-structured interviews with experienced members of the visualization community who have contributed to developing or publishing decision support systems for domain experts. Our interviewees used our typology to delineate the decision-making processes supported by their systems, demonstrating its descriptive capacity and effectiveness. Finally, we present preliminary findings on the usefulness of our typology for visualization design.

97 MATHEMATICS AND COMPUTING↗

Oxygen isotope analysis of bacterial and fungal manganese oxidation

Abstract The ability of micro‐organisms to oxidize manganese (Mn) from Mn( II ) to Mn( III / IV ) oxides transcends boundaries of biological clade or domain. Many bacteria and fungi oxidize Mn( II ) to Mn( III / IV ) oxides directly through enzymatic activity or indirectly through the production of reactive oxygen species. Here, we determine the oxygen isotope fractionation factors associated with Mn( II ) oxidation via various biotic (bacteria and fungi) and abiotic Mn( II ) reaction pathways. As oxygen in Mn( III / IV ) oxides may be derived from precursor water and molecular oxygen, we use a twofold approach to determine the isotope fractionation with respect to each oxygen source. Using both 18 O‐labeled water and closed‐system Rayleigh distillation approaches, we constrain the kinetic isotope fractionation factors associated with O atom incorporation during Mn( II ) oxidation to −17.3‰ to −25.9‰ for O 2 and −1.9‰ to +1.8‰ for water. Results demonstrate that stable oxygen isotopes of Mn( III / IV ) oxides have potential to distinguish between two main classes of biotic Mn( II ) oxidation: direct enzymatic oxidation in which O 2 is the oxidant and indirect enzymatic oxidation in which superoxide is the oxidant. The fraction of Mn( III / IV ) oxide‐associated oxygen derived from water varies significantly (38%–62%) among these bio‐oxides with only weak relationship to Mn oxidation state, suggesting Mn( III ) disproportionation may account for differences in the fraction of mineral‐bound oxygen from water and O 2 . Additionally, direct incorporation of molecular O 2 suggests that Mn( III / IV ) oxides contain a yet untapped proxy of of environmental O 2 , a parameter reflecting the integrated influence of global respiration, photorespiration, and several other biogeochemical reactions of global significance.

Sutherland, K. M.↗

Simplex‐based model for nanoparticle grain identification in four‐dimensional scanning transmission electron microscopy data

Grain identification in polycrystalline nanoparticles, for example, determining which crystal phases are present at each spatial location, is fundamental to materials characterisation. This is particularly challenging when grains overlap extensively, as commonly occurs in four-dimensional scanning transmission electron microscopy (4D-STEM) datasets. We propose a simplex-based model (SBM) in which each simplex vertex represents the diffraction pattern (DP) of a pure grain, and the simplex edges and interior represent overlapping grains. Our SBM grain identification algorithm operates on the Bragg disk (BD) data matrix distilled from the 4D-STEM data to identify the grain membership at each scan position, together with a BD feature matrix whose columns represent the DPs for each constituent grain, which is important for identifying the crystal structure of each grain. We solve the model using a two-stage algorithm. In Stage 1, we adapt a linear mixing algorithm to estimate an initial BD feature matrix whose columns represent DPs of potentially overlapping grains. Our Stage 2 algorithm incorporates sparsity considerations to transform the initial BD feature matrix so that its columns represent DPs of pure grains. Using simulated datasets with various grain configurations, we demonstrate that SBM recovers both the BD feature matrix and membership maps more accurately than existing methods, even when a grain lacks any pure region and completely overlaps with other grains.

4D-STEM segmentation↗

Trait covariance: the functional warp of plant diversity?

In 300 BC Ancient Greece, Theophrastus was one of the first to organize the diversity of plant life on Earth into categories of function and use (Theophrastus, 1916). Currently, scientists are still working to simplify the vast array of plant species and forms in order to distill general features of plant function, structure, and strategy.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental Characterization of Hygrothermal Aging: Competition Between Thermo-Oxidation and Hydrolysis Phenomena

Abstract In this work, we have presented a comparison between effects of accelerated thermo-oxidative, hydrolytic and hygrothermal aging on the mechanical and chemical properties of a polyurethane based (PUB) adhesive. The adhesive is a flexible adhesive which is extensively used in automobile industry as a glass sealant. During service life it gets exposed to the hygrothermal environment and the integrity of matrix interface is most vulnerable. This study focuses on weighing and comparing effects of different aging environments on material behavior; and it shows that hygrothermal aging environment results as a competition between two sub-aging phenomena i.e., thermo-oxidation and hydrolytic aging. Samples were exposed to 0%RH, 80%RH and submerged condition in distilled water. Uni-axial tensile tests, and cross-link density analysis by swelling test were carried out on as-received and aged samples. The aging process was conducted at three different temperatures (60°C, 80°C and 95°C) and for four different exposure durations of 1, 10, 30, and 90 days. This work confirms that the effect of hygrothermal aging is a result of competition between thermo-oxidation and hydrolytic aging environments. The total mechanical and environmental damage incurred by specimens is a collaborative effect of all exposure environments involved i.e., aging time, temperature, oxygen, water and humidity. The results are in agreement with the chemical test outcomes as well.

Shaafaey, Mamoon↗

Multi-sensor anomalous change detection in remote sensing imagery

Combining multiple satellite remote sensing sources provides a far richer, more frequent view of the earth than that of any single source; the challenge is in distilling these petabytes of heterogeneous sensor imagery into meaningful characterizations of the imaged areas. Meeting this challenge requires effective algorithms for combining multi-modal imagery over time to identify subtle but real changes among the intrinsic data variation. Here, we implement a joint-distribution framework for multi-sensor anomalous change detection (MSACD) that can effectively account for these differences in modality, and does not require any signal resampling of the pixel measurements. This flexibility enables the use of satellite imagery from different sensor platforms and modalities. We use multi-year construction of the SoFi Stadium in California as our testbed, and exploit synthetic aperture radar imagery from Sentinel-1 and multispectral imagery from both Sentinel-2 and Landsat 8. We show results for MSACD using real imagery with implanted, measurable changes, as well as real imagery with real, observable changes, including scaling our analysis over multiple years.

47 OTHER INSTRUMENTATION↗

A visual wikipedia for satellite imagery

GeoVisipedia (Geospatial Visual Wikipedia) is a new and novel approach to sharing knowledge about complex geospatial entities such as facilities. Facilities are composed of interconnected objects such as buildings, chemical processing units, electrical generation equipment and similar structures. Satellite imagery of a facility reveals a great deal about the organization and visual appearance of objects in a facility, but very little about the identity or function of the object. For example, given a satellite imagery of an oil refinery, an expert in refining readily identifies distillation units and can explain how they work. A non-expert would have a very difficult time identifying these objects let alone explaining how they function. To make highly complex information accessible to non-experts, GeoVisipedia associates a wiki page with objects in satellite imagery. A user selects an object in the image and a wiki page appears that provides the user with detailed information about the object. Experts can author information into the wiki and this information is shared with other users. Additionally, GeoVisipedia automatically transfers all wiki pages from one image of a facility to other imagery of the facility. Consequentially, knowledge about objects in the facility integrates over time as new imagery becomes available and as new wiki pages are created and additional information is added to existing wiki pages. In this respect, satellite imagery becomes a portal to expert knowledge and insight about objects in a facility.

Roberts, Randy↗

Polarization–frequency hyperentangled photons: generation, characterization, and manipulation

Frequency-bin encoding is massively parallelizable and robust for optical fiber transmission. When coupled with an additional degree of freedom (DoF), the expansion of the Hilbert space allows for deterministic controlled operations between two DoFs within a single photon. Such capabilities, when combined with photonic hyperentanglement, are of great value for quantum communication protocols, including dense coding and single-copy entanglement distillation. In this talk, we present an all-fiber-coupled, ultrabroadband polarization–frequency hyperentangled source and conduct comprehensive quantum state tomography across multiple dense wavelength division multiplexing channels spanning the optical C+L-band (1530–1625 nm). In addition, we design and implement a high-fidelity controlled-NOT (cnot) operation between polarization and frequency DoFs by exploiting electro-optic phase modulation within a fiber Sagnac loop. Collectively, our hyperentangled source and two-qubit gate should unlock new opportunities for harnessing polarization–frequency resources in established telecommunication fiber networks for future quantum applications.

Lu, Hsuan-Hao↗

{sup 18}F-FLT uptake kinetics in head and neck squamous cell carcinoma: A PET imaging study

Purpose: To analyze the kinetics of 3{sup ′}-deoxy-3{sup ′}-[F-18]-fluorothymidine (18F-FLT) uptake by head and neck squamous cell carcinomas and involved nodes imaged using positron emission tomography (PET). Methods: Two- and three-tissue compartment models were fitted to 12 tumor time-activity-curves (TACs) obtained for 6 structures (tumors or involved nodes) imaged in ten dynamic PET studies of 1 h duration, carried out for five patients. The ability of the models to describe the data was assessed using a runs test, the Akaike information criterion (AIC) and leave-one-out cross-validation. To generate parametric maps the models were also fitted to TACs of individual voxels. Correlations between maps of different parameters were characterized using Pearson'sr coefficient; in particular the phosphorylation rate-constants k{sub 3-2tiss} and k{sub 5} of the two- and three-tissue models were studied alongside the flux parameters K{sub FLT-2tiss} and K{sub FLT} of these models, and standardized uptake values (SUV). A methodology based on expectation-maximization clustering and the Bayesian information criterion (“EM-BIC clustering”) was used to distil the information from noisy parametric images. Results: Fits of two-tissue models 2C3K and 2C4K and three-tissue models 3C5K and 3C6K comprising three, four, five, and six rate-constants, respectively, pass the runs test for 4, 8, 10, and 11 of 12 tumor TACs. The three-tissue models have lower AIC and cross-validation scores for nine of the 12 tumors. Overall the 3C6K model has the lowest AIC and cross-validation scores and its fitted parameter values are of the same orders of magnitude as literature estimates. Maps ofK{sub FLT} and K{sub FLT-2tiss} are strongly correlated (r = 0.85) and also correlate closely with SUV maps (r = 0.72 for K{sub FLT-2tiss}, 0.64 for K{sub FLT}). Phosphorylation rate-constant maps are moderately correlated with flux maps (r = 0.48 for k{sub 3-2tiss} vs K{sub FLT-2tiss} and r = 0.68 for k{sub 5} vs K{sub FLT}); however, neither phosphorylation rate-constant correlates significantly with SUV. EM-BIC clustering reduces the parametric maps to a small number of levels—on average 5.8, 3.5, 3.4, and 1.4 for K{sub FLT-2tiss}, K{sub FLT}, k{sub 3-2tiss}, and k{sub 5.} This large simplification is potentially useful for radiotherapy dose-painting, but demonstrates the high noise in some maps. Statistical simulations show that voxel level noise degrades TACs generated from the 3C6K model sufficiently that the average AIC score, parameter bias, and total uncertainty of 2C4K model fits are similar to those of 3C6K fits, whereas at the whole tumor level the scores are lower for 3C6K fits. Conclusions: For the patients studied here, whole tumor FLT uptake time-courses are represented better overall by a three-tissue than by a two-tissue model. EM-BIC clustering simplifies noisy parametric maps, providing the best description of the underlying information they contain and is potentially useful for radiotherapy dose-painting. However, the clustering highlights the large degree of noise present in maps of the phosphorylation rate-constantsk{sub 5} and k{sub 3-2tiss}, which are conceptually tightly linked to cellular proliferation. Methods must be found to make these maps more robust—either by constraining other model parameters or modifying dynamic imaging protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-243: MonteCarlo Simulation Study of Polymer and Radiochromic Gel for Three-Dimensional Proton Dose Distribution

Purpose: To estimate the three dimensional dose distributions in a polymer gel and a radiochromic gel by comparing with the virtual water phantom exposed to proton beams by applying Monte Carlo simulation. Methods: The polymer gel dosimeter is the compositeness material of gelatin, methacrylic acid, hydroquinone, tetrakis, and distilled water. The radiochromic gel is PRESAGE product. The densities of polymer and radiochromic gel were 1.040 and 1.0005 g/cm3, respectively. The shape of water phantom was a hexahedron with the size of 13 × 13 × 15 cm3. The proton beam energies of 72 and 116 MeV were used in the simulation. Proton beam was directed to the top of the phantom with Z-axis and the shape of beam was quadrangle with 10 × 10 cm2 dimension. The Percent depth dose and the dose distribution were evaluated for estimating the dose distribution of proton particle in two gel dosimeters, and compared with the virtual water phantom. Results: The Bragg-peak for proton particles in two gel dosimeters was similar to the virtual water phantom. Bragg-peak regions of polymer gel, radiochromic gel, and virtual water phantom were represented in the identical region (4.3 cm) for 72 MeV proton beam. For 116 MeV proton beam, the Bragg-peak regions of polymer gel, radiochromic gel, and virtual water phantom were represented in 9.9, 9.9 and 9.7 cm, respectively. The dose distribution of proton particles in polymer gel, radiochromic gel, and virtual water phantom was approximately identical in the case of 72 and 116 MeV energies. The errors for the simulation were under 10%. Conclusion: This work indicates the evaluation of three dimensional dose distributions by exposing proton particles to polymer and radiochromic gel dosimeter by comparing with the water phantom. The polymer gel and the radiochromic gel dosimeter show similar dose distributions for the proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

MO-H-19A-04: Multichannel CW Ultrasonic Thermometry for Imaging Therapeutic Dose Fields in Water

Purpose: To develop a scalable, multichannel ultrasonic thermometry system suitable for imaging clinical-beam dose distributions in a water phantom. Method: A small, glass-walled rectangular water phantom (15 cm × 20 cm × 30 cm) was filled with distilled water, and two ultrasonic transducers were placed on the outside, against opposing walls, approximately 5 cm below the water line, and were aligned to optimize transmission/reception of ultrasound between them. Two synchronized lock-in amplifiers were connected to the transducers to enable full-duplex operation of two separate ultrasonic frequency channels configured to transmit simultaneously through the same volume of water and thereby provide independent measurements of the temperature-dependent ultrasonic phase lag. Controlled heating of the water via immersed power resistors provided a means to study dependence of measured phase lag on temperature change for both channels; cross-correlation of the phase outputs enabled much smaller temperature fluctuations in the phantom to be used to ascertain the noise floor and achievable temperature resolution. Results: Temperature measurements from both channels, converted from phase measurements via polynomials available in the literature, exhibited the expected linear dependence of ultrasonic phase on temperature change (measured via calibrated thermistor probe). Cross-correlation analysis of phase fluctuations yielded rms noise estimates of approximately 1-2 microKelvin, comparable to that observed in standard water calorimeters. Conclusion: Phase-sensitive detection of cw ultrasound has been shown to provide temperature sensitivity needed for calorimetry of external treatment beams, and the present simple demonstration establishes that multiple channels may be run simultaneously without phase disturbances that currently affect time-of-flight techniques utilizing phase-detection. Immediate plans include doubling the number of sensors, to enable a simple tomographic reconstruction, and to test the system in Clinac x-rays and electron beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-210-07: The Dependence On Acoustic Velocity of Medium On the Needle Template and Electronic Grid Alignment in Ultrasound QA for Prostate Brachytherapy

Purpose: To analyze the impact on acoustic velocity (AV) of two different media (water and milk) using the needle template/electronic grid alignment test. Water, easily available, makes a good material to test the alignment of the template and grid although water’s AV (1498 m/s at 25°C) is significantly different from tissue (1540 m/s). Milk, with an AV much closer (1548 m/s) to prostate tissue, may be a good substitute for water in ultrasound quality assurance testing. Methods: Tests were performed using a Hitachi ultrasound unit with a mechanical arrangement designed to position needles parallel to the transducer. In this work, two materials – distilled water and homogenized whole milk (AVs of 1498 and 1548 m/s at 25°C) were used in a phantom to test ultrasound needle/grid alignment. The images were obtained with both materials and analyzed for their placement accuracy. Results: The needle template/electronic grid alignment tests showed displacement errors between measured and calculated values. The measurements showed displacements of 2.3mm (water) and 0.4mm (milk), and 1.6mm (water) and 0.3mm (milk) at depths of 7cm and 5cm respectively from true needle positions. The calculated results showed a displacement of 2.36 mm (water); 0.435mm (milk), and 1.66mm (water) and 0.31mm (milk) at a depth of 7cm and 5cm respectively. The displacements in the X and Y directions were also calculated. At depths of 7cm and 5cm, the (ΔX,ΔY) displacements in water were (0.829mm, 2.21mm) and (0.273mm, 1.634mm) and for milk were (0.15mm, 0.44mm) and (0.05mm, 0.302mm) respectively. Conclusion: The measured and calculated values were in good agreement for all tests. They show that milk provides superior results when performing needle template and electronic grid alignment tests for ultrasound units used in prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

SU-E-J-224: Using UTE and T1 Weighted Spin Echo Pulse Sequences for MR-Only Treatment Planning; Phantom Study

Purpose: Investigating a new approach in MRI based treatment planning using the combination of (Ultrashort Echo Time) UTE and T1 weighted spin echo pulse sequences to delineate air, bone and water (soft tissues) in generating pseudo CT images comparable with CT. Methods: A gel phantom containing chicken bones, ping pang balls filled with distilled water and air bubbles, was made. It scanned with MRI using UTE and 2D T1W SE pulse sequences with (in plane resolution= 0.53mm, slice thickness= 2 mm) and CT with (in plane resolution= 0.5 mm and slice thickness= 0.75mm) as a ground truth for geometrical accuracy. The UTE and T1W SE images were registered with CT using mutual information registration algorithm provided by Philips Pinnacle treatment planning system. The phantom boundaries were detected using Canny edge detection algorithm for CT, and MR images. The bone, air bubbles and water in ping pong balls were segmented from CT images using threshold 300HU, - 950HU and 0HU, respectively. These tissue inserts were automatically segmented from combined UTE and T1W SE images using edge detection and relative intensity histograms of the phantom. The obtained segmentations of air, bone and water inserts were evaluated with those obtained from CT. Results: Bone and air can be clearly differentiated in UTE images comparable to CT. Combining UTE and T1W SE images successfully segmented the air, bone and water. The maximum segmentation differences from combine MRI images (UTE and T1W SE) and CT are within 1.3 mm, 1.1mm for bone, air, respectively. The geometric distortion of UTE sequence is small less than 1 pixel (0.53 mm) of MR image resolution. Conclusion: Our approach indicates that MRI can be used solely for treatment planning and its quality is comparable with CT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-257: Development of a New Endorectal Balloon with An Unfoldable Radiochromic Film for In-Vivo Rectal Dosimetry During Prostate Cancer Radiotherapy

Purpose: We developed an endorectal balloon for in-vivo rectal dosimetry in two-dimensions, and evaluated its dosimetric properties for the radiation treatment of prostate cancer. Methods: The endorectal balloon for in-vivo rectal dosimetry is equipped with a radiochromic film so that two-dimensional dose distribution can be measured in the rectal wall. The film is unrolled as the balloon is inflated, and it is rolled as the balloon is deflated. The outer diameter of the balloon is about 14 mm before inflating it, but its outer diameter can be increased up to about 50 mm after inflating it with 80 ml distilled water. The size of the film is 80(L) x 64(W) mm2, so large as to measure a dose distribution of an anterior half of the rectal wall. After it was inserted into a fabricated rectal phantom, the phantom was scanned by a CT scanner and 5 Gy was delivered to a target inside the phantom with a 15 MV photon beam in AP direction. Finally, the dose distribution measured in the endorectal balloon was compared with that of the treatment plan. Results: The two dose distributions were compared each other in the parallel and the perpendicular directions along an axis of the balloon. The two dose profiles analyzed from the radiochromic film agreed well with the plan within 3% for 15 MV photon beam. Conclusion: An endorectal balloon for two-dimensional in-vivo rectal dosimetry was developed and its dosimetric effectiveness was evaluated for the radiation treatment of prostate cancer. The measured dose distributions showed good agreement with the plans.

60 APPLIED LIFE SCIENCES↗

SU-F-I-19: MRI Positive Contrast Visualization of Prostate Brachytherapy Seeds Using An Integrated Laplacian-Based Phase Processing

Purpose: To propose a new method that provides a positive contrast visualization of the prostate brachytherapy seeds using the phase information from MR images. Additionally, the feasibility of using the processed phase information to distinguish seeds from calcifications is explored. Methods: A gel phantom was constructed using 2% agar dissolved in 1 L of distilled water. Contrast agents were added to adjust the relaxation times. Four iodine-125 (Eckert & Ziegler SML86999) dummy seeds were placed at different orientations with respect to the main magnetic field (B0). Calcifications were obtained from a sheep femur cortical bone due to its close similarity to human bone tissue composition. Five samples of calcifications were shaped into different dimensions with lengths ranging between 1.2 – 6.1 mm.MR imaging was performed on a 3T Philips Achieva using an 8-channel head coil. Eight images were acquired at eight echo-times using a multi-gradient echo sequence. Spatial resolution was 0.7 × 0.7 × 2 mm, TR/TE/dTE = 20.0/2.3/2.3 ms and BW = 541 Hz/pixel. Complex images were acquired and fed into a two-step processing pipeline: the first includes phase unwrapping and background phase removal using Laplacian operator (Wei et al. 2013). The second step applies a specific phase mask on the resulting tissue phase from the first step to provide the desired positive contrast of the seeds and to, potentially, differentiate them from the calcifications. Results: The phase-processing was performed in less than 30 seconds. The proposed method has successfully resulted in a positive contrast of the brachytherapy seeds. Additionally, the final processed phase image showed difference between the appearance of seeds and calcifications. However, the shape of the seeds was slightly distorted compared to the original dimensions. Conclusion: It is feasible to provide a positive contrast of the seeds from MR images using Laplacian operator-based phase processing.

60 APPLIED LIFE SCIENCES↗

SU-F-J-172: Hybrid MR/CT Compatible Phantom for MR-Only Based Radiotherapy

Purpose: Development of hybrid MR/CT compatible phantom was introduced to fully establish MR image only radiation treatment and this suggested technique using in-house developed hybrid MR/CT compatible phantom image would utilize to generate radiation treatment planning and perform dose calculation without multi-modal registration process or generation of pseudo CT. Methods: Fundamental characteristics for “hybrid MR/CT compatible phantom” was established: Relaxation times equivalent to human tissue, dielectric properties, homogeneous relaxation times, sufficient strength to fabricate a torso, ease of handling, a wide variety of density material for calibration, chemical and physical stability over an extended time. For this requirements, chemical component in each tested plug which would be tissue equivalent to human tissue on MR and CT image and production of phantom body and plug was performed. Chemical component has described below: Agaros, GdCl{sub 3}, NaN{sub 3}, NaCl, K{sub 2}Co{sub 3}, deionized-distilled water. Various mixture of chemical component to simulate human tissue on both MR and CT image was tested by measuring T1, T2 relaxation time and signal intensity (SI) on MR image and Hounsfield unit (HU) on CT and each value was compared. The hybrid MR/CT compatible phantom with 14 plugs was designed and has made. Total height and external diameter was decided by internal size of 32 channel MR head-coil. Results: Tissue-equivalent chemical component materials and hybrid MR/CT compatible phantom was developed. The range of T1, T2 relaxation time and SI on MR image, HU on CT was acquired and could be adjusted to correspond to simulated human tissue. Conclusion: Current result shows its possibility for MR-only based radiotherapy and the best mixing rate of chemical component for tissue-equivalent image on MR and CT was founded. However, additional technical issues remain to be overcome. Conversion of SI on MR image into HU and dose calculation based on converted MRI will be progressing.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP2-12: The Effect of Iterative Reconstruction and CT Tube Voltage On Hounsfield Unit Values of Iodinated Contrast

Purpose: To investigate the effects of changing iterative reconstruction strength and tube voltage on Hounsfield Unit (HU) values of varying concentrations of Iodinated contrast medium in a phantom. Method: Iodinated contrast (Omnipaque 300, GE Healthcare, Princeton NJ) was diluted with distilled water to concentrations of 0.6, 0.9, 1.8, 3.6, 7.2, and 10.8 mg/mL of Iodine. The solutions were scanned in a patient equivalent water phantom on two MDCT scanners: VCT 64 slice (GE Medical Systems, Waukesha, WI) and an Aquilion One 320 slice scanner (Toshiba America Medical Systems, Tustin CA). The phantom was scanned at 80, 100, 120, 140 kV using 400, 255, 180, and 130 mAs, respectively, for the VCT scanner, and 80, 100, 120, and 135 kV using 400, 250, 200, and 150 mAs, respectively, on the Aquilion One. Images were reconstructed at 2.5 mm (VCT) and 0.5 mm (Aquilion One). The VCT images were reconstructed using Advanced Statistical Iterative Reconstruction (ASIR) at 6 different strengths: 0%, 20%, 40%, 60%, 80%, and 100%. Aquilion One images were reconstructed using Adaptive Iterative Dose Reduction (AIDR) at 4 strengths: no AIDR, Weak AIDR, Standard AIDR, and Strong AIDR. Regions of interest (ROIs) were drawn on the images to measure the HU values and standard deviations of the diluted contrast. Second order polynomials were used to fit the HU values as a function of Iodine concentration. Results: For both scanners, there was no significant effect of changing the iterative reconstruction strength. The polynomial fits yielded goodness-of-fit (R2) values averaging 0.997. Conclusion: Changing the strength of the iterative reconstruction has no significant effect on the HU values of Iodinated contrast in a tissue-equivalent phantom. Fit values of HU vs Iodine concentration are useful in quantitative imaging protocols such as the determination of cardiac output from time-density curves in the main pulmonary artery.

60 APPLIED LIFE SCIENCES↗

Provably secure and high-rate quantum key distribution with time-bin qudits

The security of conventional cryptography systems is threatened in the forthcoming era of quantum computers. Quantum key distribution (QKD) features fundamentally proven security and offers a promising option for quantum-proof cryptography solution. Although prototype QKD systems over optical fiber have been demonstrated over the years, the key generation rates remain several orders of magnitude lower than current classical communication systems. In an effort toward a commercially viable QKD system with improved key generation rates, we developed a discrete-variable QKD system based on time-bin quantum photonic states that can generate provably secure cryptographic keys at megabit-per-second rates over metropolitan distances. We use high-dimensional quantum states that transmit more than one secret bit per received photon, alleviating detector saturation effects in the superconducting nanowire single-photon detectors used in our system that feature very high detection efficiency (of more than 70%) and low timing jitter (of less than 40 ps). Our system is constructed using commercial off-the-shelf components, and the adopted protocol can be readily extended to free-space quantum channels. In conclusion, the security analysis adopted to distill the keys ensures that the demonstrated protocol is robust against coherent attacks, finite-size effects, and a broad class of experimental imperfections identified in our system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗