Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

SU-D-304-04: Pre-Clinical Feasibility Study for Intensity Modulated Grid Proton Therapy (IMgPT) Using a Newly Developed Delivery System

Purpose: The purpose of the current study was to characterize and evaluate intensity-modulated proton grid therapy (IMgPT) using a clinical proton beam. Methods: A TOPAS MC model of a new developmental mode (pre-clinical) of the Hitachi proton therapy system (PROBEAT) was used for simulation and characterization of proton grid therapy. TOPAS simulations of different energy ranges, depths and spot separation distances were performed. LET spectra for various energies and depths were produced with FLUKA MC code for evaluation potential interplay between planning parameters and their effect on the characterization of areas (valley) between spots. IMgPT planning aspects (spot spacing, skin dose, peak-to-valley ratios, beam selection, etc.) were evaluated for different phantom and patient cases. Raysearch software (v4.51) was used to perform the evaluation. Results: Calculated beam peak-to-valley ratios scenarios showed strong energy and depth dependence with ratios to be larger for higher energies and shallower depths. Peak-to-valley ratios for R90 range and for spot spacing of 1cm varied from 30% (E = 221.3 MeV, depth 30.6 cm) to 80% (E = 70.3 MeV, depth 4 cm). LET spectra calculations showed spectral hardening with depth, which might potential increase, spot separation distance and improve peak-to-valley ratios. IMgPT optimization, using constant spot spacing, showed skin dose reduction between peak regions of dose due to the irradiation of less skin. Single beam for bulky shallower tumors might be a potential candidate for proton grid therapy. Conclusions: Proton grid therapy using a clinical beam is a promising technique that reduces skin dose between peak regions of dose and may be suitable for the treatment of shallow tumors. IMgPT may be considered for use when bystander effects in off peak regions would be appropriate.

60 APPLIED LIFE SCIENCES↗

MatMCNP v. 4.0

https://www.osti.gov/doecMatMCNP is a code for generating material cards for the MCNP radiation transport code. The program allows for material specification as either atomic or weight percent (fractions). MatMCNP also permits the specification of enriched lithium, boron, and/or uranium. In addition to producing the material cards for MCNP, the code calculates the atomic (or number) density in atoms/barn-cm as well as the multiplier that should be used to convert neutron and gamma fluences into dose in the material specified.

Depriest, Kendall↗

Argonne National Laboratory Site Environmental Report for Calendar Year 2011

This report discusses the status and the accomplishments of the environmental protection program at Argonne National Laboratory for calendar year 2011. The status of Argonne environmental protection activities with respect to compliance with the various laws and regulations is discussed, along with environmental management, sustainability efforts, environmental corrective actions, and habitat restoration. To evaluate the effects of Argonne operations on the environment, samples of environmental media collected on the site, at the site boundary, and off the Argonne site were analyzed and compared with applicable guidelines and standards. A variety of radionuclides were measured in air, surface water, on-site groundwater, and bottom sediment samples. In addition, chemical constituents in surface water, groundwater, and Argonne effluent water were analyzed. External penetrating radiation doses were measured, and the potential for radiation exposure to off-site population groups was estimated. Results are interpreted in terms of the origin of the radioactive and chemical substances (i.e., natural, Argonne, and other) and are compared with applicable standards intended to protect human health and the environment. A U.S. Department of Energy (DOE) dose calculation methodology, based on International Commission on Radiological Protection (ICRP) recommendations and the U.S. Environmental Protection Agency’s (EPA) CAP-88 Version 3 computer code, was used in preparing this report.

Davis, Theresa M.↗

Argonne National Laboratory Site Environmental Report for Calendar Year 2013

This report discusses the status and the accomplishments of the environmental protection program at Argonne National Laboratory for calendar year 2013. The status of Argonne environmental protection activities with respect to compliance with the various laws and regulations is discussed, along with environmental management, sustainability efforts, environmental corrective actions, and habitat restoration. To evaluate the effects of Argonne operations on the environment, samples of environmental media collected on the site, at the site boundary, and off the Argonne site were analyzed and compared with applicable guidelines and standards. A variety of radionuclides were measured in air, surface water, on-site groundwater, and bottom sediment samples. In addition, chemical constituents in surface water, groundwater, and Argonne effluent water were analyzed. External penetrating radiation doses were measured, and the potential for radiation exposure to off-site population groups was estimated. Results are interpreted in terms of the origin of the radioactive and chemical substances (i.e., natural, Argonne, and other) and are compared with applicable standards intended to protect human health and the environment. A U.S. Department of Energy (DOE) dose calculation methodology, based on International Commission on Radiological Protection (ICRP) recommendations and the U.S. Environmental Protection Agency’s (EPA) CAP-88 Version 3 computer code, was used in preparing this report.

54 ENVIRONMENTAL SCIENCES↗

Argonne National Laboratory Site Environmental Report (CY2019)

This report discusses the status and the accomplishments of the environmental protection program at Argonne National Laboratory for calendar year 2019. The status of Argonne environmental protection activities with respect to compliance with the various laws and regulations is discussed, along with environmental management, sustainability efforts, environmental corrective actions, and habitat restoration. To evaluate the effects of Argonne operations on the environment, samples of environmental media collected on the site, at the site boundary, and off the Argonne site were analyzed and compared with applicable guidelines and standards. A variety of radionuclides were measured in air, surface water, groundwater, and bottom sediment samples. In addition, chemical constituents in surface water, groundwater, and wastewater were analyzed. External penetrating radiation doses were measured, and the potential for radiation exposure to off-site population groups was estimated. Results are interpreted with respect to the origin of the radioactive and chemical substances (i.e., natural, Argonne, and other) and are compared with applicable standards intended to protect human health and the environment. A U.S. Department of Energy (DOE) dose calculation methodology, based on International Commission on Radiological Protection (ICRP) recommendations and the U.S. Environmental Protection Agency’s (EPA) CAP-88 Version 4 computer code, was used in preparing this report.

54 ENVIRONMENTAL SCIENCES↗

Argonne National Laboratory Site Environmental Report (CY2020)

This report discusses the status and the accomplishments of the environmental protection program at Argonne National Laboratory for calendar year 2020. The status of Argonne environmental protection activities with respect to compliance with the various laws and regulations is discussed, along with environmental management, sustainability efforts, environmental corrective actions, and habitat restoration. To evaluate the effects of Argonne operations on the environment, samples of environmental media collected on the site, at the site boundary, and off the Argonne site were analyzed and compared with applicable guidelines and standards. A variety of radionuclides were measured in air, surface water, groundwater, and bottom sediment samples. In addition, chemical constituents in surface water, groundwater, and wastewater were analyzed. External penetrating radiation doses were measured, and the potential for radiation exposure to off site population groups was estimated. Results are interpreted with respect to the origin of the radioactive and chemical substances (i.e., natural, Argonne, and other) and are compared with applicable standards intended to protect human health and the environment. A U.S. Department of Energy (DOE) dose calculation methodology, based on International Commission on Radiological Protection (ICRP) recommendations and the U.S. Environmental Protection Agency’s (EPA) CAP 88 Version 4.1 computer code, was used in preparing this report.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Argonne National Laboratory Site Environmental Report for Calendar Year 2021

This report discusses the status and the accomplishments of the environmental protection program at Argonne National Laboratory for calendar year 2021. The status of Argonne environmental protection activities with respect to compliance with the various laws and regulations is discussed, along with environmental management, sustainability efforts, environmental corrective actions, and habitat restoration. To evaluate the effects of Argonne operations on the environment, samples of environmental media collected on the site, at the site boundary, and off the Argonne site were analyzed and compared with applicable guidelines and standards. A variety of radionuclides were measured in air, surface water, groundwater, and bottom sediment samples. In addition, chemical constituents in surface water, groundwater, and wastewater were analyzed. External penetrating radiation doses were measured, and the potential for radiation exposure to off site population groups was estimated. Results are interpreted with respect to the origin of the radioactive and chemical substances (i.e., natural, Argonne, and other) and are compared with applicable standards intended to protect human health and the environment. A U.S. Department of Energy (DOE) dose calculation methodology, based on International Commission on Radiological Protection (ICRP) recommendations and the U.S. Environmental Protection Agency’s (EPA) CAP 88 Version 4.1 computer code, was used in preparing this report.

54 ENVIRONMENTAL SCIENCES↗

Argonne National Laboratory Site Environmental Report for Calendar Year 2022

This report discusses the status and the accomplishments of the environmental protection program at Argonne National Laboratory for calendar year 2022. The status of Argonne environmental protection activities with respect to compliance with the various laws and regulations is discussed, along with environmental management, sustainability efforts, environmental corrective actions, and habitat restoration. To evaluate the effects of Argonne operations on the environment, samples of environmental media collected on the site, at the site boundary, and off the Argonne site were analyzed and compared with applicable guidelines and standards. A variety of radionuclides were measured in air, surface water, groundwater, and bottom sediment samples. In addition, chemical constituents in surface water, groundwater, and wastewater were analyzed. External penetrating radiation doses were measured, and the potential for radiation exposure to off site population groups was estimated. Results are interpreted with respect to the origin of the radioactive and chemical substances (i.e., natural, Argonne, and other) and are compared with applicable standards intended to protect human health and the environment. A U.S. Department of Energy (DOE) dose calculation methodology, based on International Commission on Radiological Protection (ICRP) recommendations and the U.S. Environmental Protection Agency’s (EPA) CAP 88 Version 4.1 computer code, was used in preparing this report.

54 ENVIRONMENTAL SCIENCES↗

MatMCNP V. 3.0

A code for generating MCNP material cards (MatMCNP) has been written and verified for naturally occurring, stable isotopes. The program allows for material specification as either atomic or weight percent (fractions). MatMCNP also permits the specification of enriched lithium, boron, and/or uranium. In addition to producing the material cards for MCNP, the code calculates the atomic (or number) density in atoms/barn-cm as well as the multiplier that should be used to convert neutron and gamma fluences into dose in the material specified.

Source record↗

MO-E-17A-08: Attenuation-Based Size Adjusted, Scanner-Independent Organ Dose Estimates for Head CT Exams: TG 204 for Head CT

Purpose: AAPM Task Group 204 described size specific dose estimates (SSDE) for body scans. The purpose of this work is to use a similar approach to develop patient-specific, scanner-independent organ dose estimates for head CT exams using an attenuation-based size metric. Methods: For eight patient models from the GSF family of voxelized phantoms, dose to brain and lens of the eye was estimated using Monte Carlo simulations of contiguous axial scans for 64-slice MDCT scanners from four major manufacturers. Organ doses were normalized by scannerspecific 16 cm CTDIvol values and averaged across all scanners to obtain scanner-independent CTDIvol-to-organ-dose conversion coefficients for each patient model. Head size was measured at the first slice superior to the eyes; patient perimeter and effective diameter (ED) were measured directly from the GSF data. Because the GSF models use organ identification codes instead of Hounsfield units, water equivalent diameter (WED) was estimated indirectly. Using the image data from 42 patients ranging from 2 weeks old to adult, the perimeter, ED and WED size metrics were obtained and correlations between each metric were established. Applying these correlations to the GSF perimeter and ED measurements, WED was calculated for each model. The relationship between the various patient size metrics and CTDIvol-to-organ-dose conversion coefficients was then described. Results: The analysis of patient images demonstrated the correlation between WED and ED across a wide range of patient sizes. When applied to the GSF patient models, an exponential relationship between CTDIvol-to-organ-dose conversion coefficients and the WED size metric was observed with correlation coefficients of 0.93 and 0.77 for the brain and lens of the eye, respectively. Conclusion: Strong correlation exists between CTDIvol normalized brain dose and WED. For the lens of the eye, a lower correlation is observed, primarily due to surface dose variations. Funding Support: Siemens-UCLA Radiology Master Research Agreement; Disclosures - Michael McNitt-Gray: Institutional Research Agreement, Siemens AG; Research Support, Siemens AG; Consultant, Flaherty Sensabaugh Bonasso PLLC; Consultant, Fulbright and Jaworski.

60 APPLIED LIFE SCIENCES↗

SU-E-T-580: On the Significance of Model Based Dosimetry for Breast and Head and Neck 192Ir HDR Brachytherapy

Purpose: To assess the dosimetric and radiobiological differences between TG43-based and model-based dosimetry in the treatment planning of {sup 192}Ir HDR brachytherapy for breast and head and neck cancer. Methods: Two cohorts of 57 Accelerated Partial Breast Irradiation (APBI) and 22 head and neck (H&N) patients with oral cavity carcinoma were studied. Dosimetry for the treatment plans was performed using the TG43 algorithm of the Oncentra Brachy v4.4 treatment planning system (TPS). Corresponding Monte Carlo (MC) simulations were performed using MCNP6 with input files automatically prepared by the BrachyGuide software tool from DICOM RT plan data. TG43 and MC data were compared in terms of % dose differences, Dose Volume Histograms (DVHs) and related indices of clinical interest for the Planning Target Volume (PTV) and the Organs-At-Risk (OARs). A radiobiological analysis was also performed using the Equivalent Uniform Dose (EUD), mean survival fraction (S) and Tumor Control Probability (TCP) for the PTV, and the Normal Tissue Control Probability (N TCP) and the generalized EUD (gEUD) for the OARs. Significance testing of the observed differences performed using the Wilcoxon paired sample test. Results: Differences between TG43 and MC DVH indices, associated with the increased corresponding local % dose differences observed, were statistically significant. This is mainly attributed to their consistency however, since TG43 agrees closely with MC for the majority of DVH and radiobiological parameters in both patient cohorts. Differences varied considerably among patients only for the ipsilateral lung and ribs in the APBI cohort, with a strong correlation to target location. Conclusion: While the consistency and magnitude of differences in the majority of clinically relevant DVH indices imply that no change is needed in the treatment planning practice, individualized dosimetry improves accuracy and addresses instances of inter-patient variability observed. Research co-financed by the ESF and Greek funds through the Operational Program Education and Lifelong Learning Investing in Knowledge Society of the NSRF. Research Funding Program Aristeia. Nucletron, an Elekta company (Veenendaal, The Netherlands) is gratefully acknowledged for providing Oncentra Brachy v4.4 for research purposes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Field of Packages Carrying Spent Co-60 Radioactive Sources - 12437

Among the diverse radioactive sources commonly exploited in medical and industrial applications, Co- 60 is increasingly used as strong gamma emitter. Over time, source manufacturers favored Co-60 as opposed to other gamma emitters because its relatively short half-life (5.27 year) that minimizes issues related to the management of disused sources. Disused Co-60 sources can retain a significant amount of radioactivity (from hundreds of MBq to several GBq) that still poses safety concerns on their handling and transportation. In this context a detailed knowledge of their radiation field would provide the necessary information for taking actions in preventing unnecessary doses to the workers and the population by optimizing transportation procedures and handling operations. We modeled the geometry and the materials constituting a transportation packaging of a spent Co-60 source which had an original maximum activity of a few GBq and was enclosed in a small lead irradiator. Then we applied a Monte Carlo transport code (MCNP5) for tracking down the gamma photons emitted by the source, including the secondary photons resulting by the interaction of the source photons with the surrounding materials. This allowed for the evaluation of the radiation field inside and outside the packaging, and the corresponding equivalent dose useful for checking the compliance with the regulations and the health risk of possible radiation exposure. We found that a typical 60-liters drum carrying a spent Co-60 source, enclosed in its original irradiator, with a residual activity of 300 MBq could already overcome an equivalent dose of 0.2 mSv/h on the drum external surface, which is the maximum equivalent dose at any point of the surface for this packaging as prescribed by local regulations. This condition is even more apparent when the source is slightly displaced with respect to the rotation axis of the drum, an easily occurring condition for sources not properly packaged, generating non-compliant hot-spots on the drum surface. As an example, a displacement of 5 cm translates in an increase of 80% in the dose level on the nearest side of the drum. We also found that the equivalent dose is significantly influenced by the scattered source photons and the secondary photons, whose contribution to the radiation field is mainly determined by the package geometry. The developed model resulted in an important tool for exploring the detail of the radiation field of a spent Co-60 source packaged for transportation allowing to check for compliance with the regulations and to evaluate risks to the workers and the population. It is worth to point out that this modeling approach is completely general and can be applied to a variety of different problems not limited to the transportation of radioactive material. In the example illustrated in this work, a small Co-60 source inside its irradiator and properly packaged in a drum for transport, presents a hot-spot on the drum surface if the irradiator is displaced of just few centimeters with respect to the rotation axis of the drum. A Monte Carlo simulation provided a complete description of the radiation field in the volume surrounding the packaging as a function of photon energy showing that a significant contribution comes from source photons scattered by the package itself. As an example, the Transport Index (TI) of this packaging was calculated, resulting in a value of 0.5. This value is low when compared to the regulations, however suggests that an individual just 1 meter afar from the packaging receives, in a few hours, a dose comparable to that received with a radiograph. This might be the case of the driver of a truck transporting the packaging, in particular when a number of packages are transported at the same time. It is important to notice that the results presented in this work are general, and can be appropriately scaled to represent the radiation field of similar geometries with gamma sources of different activity. However, this quick application of a Monte Carlo simulation provides useful insights in the process of preparing a packaging for transport. This simple model suggests that this approach can be efficient for screening a number of packaging configurations and flagging those potentially not compliant with regulations, that will require a more thorough care in the packaging process. Furthermore the knowledge of the details of the radiation field can be useful for optimizing the geometry of the transport cargo, and becomes essential when a variety of packaging are transported or stored, in order to prevent hazardous situations during their handling, and hence preventing unnecessary doses to the workers and the populations. It is worth to point out that this modeling approach is completely general and can be applied to a variety of different problems not limited to the transportation of radioactive material. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-634: Pre-Verification of FFF Prostate VMAT Plans with Gamma Method and DVHs Reconstructed Based On Measurements with 2D-ARRAY (PTW 1500) and OCTAVIUS 4D

Purpose: The aim of this work was to characterize the clinical correctness of FFF prostate treatment VMAT plans based on analysis of DVHs reconstructed from pre-verification 2D-arrays measurements. Methods: The new 2D ion chamber array 1500 with rotational phantom cylindrical Octavius 4D and Verisoft 6.1 software with DVH option (PTW, Freiburg) were used to determine the clinical usefulness of the treatment plans. Ten patients treated with VMAT high-fractionated (2 fraction x 7,5 Gy) FFF prostate plans (TrueBeam, Varian) were analyzed using the 3D gamma analysis by local dose method with a 5% threshold for various tolerance parameters DTA [mm] and DD [%] were 1%/1, 2%/2, 3%/3. Additional, based on the measurements of irradiation dose distributions and patients’ CT scans with contoured structures of organs, the DVHs were reconstructed using a software. The obtained DVHs were compared to planned dose distributions and the deviations were analysed with parameters: for CTV D50, D98, D2, and D25, D50, Dmax for OARs — rectum, bladder and left/right femoral heads. Results: The analyzed treatment plans passed gamma criteria (3/3%; 95%), the results obtained were as follow: mean value and standard deviation of gamma score for criteria (DTA[mm]/DD[%]): 1/1% (L53.3±3.2); 2/2% (L87.0±2.2); 3/3% (L97.5±0.9). In the DVH analysis, the highest differences were observed for OARs (especially for bladder): the mean percentage differences values for rectum, bladder and left/right femoral heads were: D25 (1.67; 6.83)%, D50 (0.18; 7.18; 1.53; 0.30)%, Dmax (−0.84; −1.64; 0.37; −4.63)%, respectively. For the CTV mean relative deviations for proper parameters were in good agreement with TPS: D98 (0.95±2.21)%, D50 (1.93±0.67)%, D2 (1.76±0.76)%. Conclusion: The gamma method is recommended tool for pre-verification analysis of correctness of treatment plans. Moreover, the scrutiny checking with reconstructed DVH gives additional, clinical information about quality of plan, especially about coverage of CTV and sparing of health tissues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster — Thur Eve — 21: Off-axis dose perturbation effects in water in a 5 × 5 cm{sup 2} 18 MV photon beam for the PTW microLion and Exradin A1SL ionization chambers

A PTW microLion liquid ionization chamber and an Exradin A1SL air-filled ionization chamber have been modeled using the egs-chamber user code of the EGSnrc system to determine their perturbation effects in water in a 5 × 5 cm{sup 2} 18 MV photon beam. A model of the Varian CL21EX linear accelerator was constructed using the BEAMnrc Monte Carlo code, and was validated by comparing measured PDDs and profiles from the microLion and A1SL chambers to calculated results that included chamber models. Measured PDDs for a 5 × 5 cm{sup 2} field for the microLion chamber agreed with calculations to within 1.5% beyond a depth of 0.5 cm, and the A1SL PDDs agreed within 1.0% beyond 1.0 cm. Measured and calculated profiles at 10 cm depth agreed within 1.0% for both chambers inside the field, and within 4.0% near the field edge. Local percent differences increased up to 15% at 4 cm outside the field. The ratio of dose to water in the absence of the chamber relative to dose in the chamber's active volume as a function of off-axis distance was calculated using the egs-chamber correlated sampling technique. The dose ratio was nearly constant inside the field and consistent with the stopping power ratios of water to detector material, but varied up to 3.3% near the field edge and 5.2% at 4 cm outside the field. Once these perturbation effects are fully characterized for more field sizes and detectors, they could be applied to clinical water tank measurements for improved dosimetric accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

Backscatter dose effects for high atomic number materials being irradiated in the presence of a magnetic field: A Monte Carlo study for the MRI linac

Purpose: To quantify and explain the backscatter dose effects for clinically relevant high atomic number materials being irradiated in the presence of a 1.5 T transverse magnetic field. Methods: Interface effects were investigated using Monte Carlo simulation techniques. We used GPUMCD (v5.1) and GEANT4 (v10.1) for this purpose. GPUMCD is a commercial software written for the Elekta AB, MRI linac. Dose was scored using GPUMCD in cubic voxels of side 1 and 0.5 mm, in two different virtual phantoms of dimensions 20 × 20 × 20 cm and 5 × 5 × 13.3 cm, respectively. A photon beam was generated from a point 143.5 cm away from the isocenter with energy distribution sampled from a histogram representing the true Elekta, MRI linac photon spectrum. A slab of variable thickness and position containing either bone, aluminum, titanium, stainless steel, or one of the two different dental filling materials was inserted as an inhomogeneity in the 20 × 20 × 20 cm phantom. The 5 × 5 × 13.3 cm phantom was used as a clinical test case in order to explain the dose perturbation effects for a head and neck cancer patient. The back scatter dose factor (BSDF) was defined as the ratio of the doses at a given depth with and without the presence of the inhomogeneity. Backscattered electron fluence was calculated at the inhomogeneity interface using GEANT4. A 1.5 T magnetic field was applied perpendicular to the direction of the beam in both phantoms, identical to the geometry in the Elekta MRI linac. Results: With the application of a 1.5 T magnetic field, all the BSDF’s were reduced by 12%–47%, compared to the no magnetic field case. The corresponding backscattered electron fluence at the interface was also reduced by 45%–64%. The reduction in the BSDF at the interface, due to the application of the magnetic field, is manifested in a different manner for each material. In the case of bone, the dose drops at the interface contrary to the expected increase when no magnetic field is applied. In the case of aluminum, the dose at the interface is the same with and without the presence of the aluminum. For all of the other materials the dose increases at the interface. Conclusions: The reduction in dose at the interface, in the presence of the magnetic field, is directly related to the reduction in backscattered electron fluence. This reduction occurs due to two different reasons. First, the electron spectrum hitting the interface is changed when the magnetic field is turned on, which results in changes in the electron scattering probability. Second, some electrons that have curved trajectories due to the presence of the magnetic field are absorbed by the higher density side of the interface and no longer contribute to the backscattered electron fluence.

60 APPLIED LIFE SCIENCES↗

TU-FG-BRB-05: A 3 Dimensional Prompt Gamma Imaging System for Range Verification in Proton Radiotherapy

Purpose: To report on the initial developments of a clinical 3-dimensional (3D) prompt gamma (PG) imaging system for proton radiotherapy range verification. Methods: The new imaging system under development consists of a prototype Compton camera to measure PG emission during proton beam irradiation and software to reconstruct, display, and analyze 3D images of the PG emission. For initial test of the system, PGs were measured with a prototype CC during a 200 cGy dose delivery with clinical proton pencil beams (ranging from 100 MeV – 200 MeV) to a water phantom. Measurements were also carried out with the CC placed 15 cm from the phantom for a full range 150 MeV pencil beam and with its range shifted by 2 mm. Reconstructed images of the PG emission were displayed by the clinical PG imaging software and compared to the dose distributions of the proton beams calculated by a commercial treatment planning system. Results: Measurements made with the new PG imaging system showed that a 3D image could be reconstructed from PGs measured during the delivery of 200 cGy of dose, and that shifts in the Bragg peak range of as little as 2 mm could be detected. Conclusion: Initial tests of a new PG imaging system show its potential to provide 3D imaging and range verification for proton radiotherapy. Based on these results, we have begun work to improve the system with the goal that images can be produced from delivery of as little as 20 cGy so that the system could be used for in-vivo proton beam range verification on a daily basis.

60 APPLIED LIFE SCIENCES↗

SU-F-T-300: Impact of Electron Density Modeling of ArcCHECK Cylindricaldiode Array On 3DVH Patient Specific QA Software Tool Analysis

Purpose: 3DVH software is a patient specific quality assurance tool which estimates the 3D dose to the patient specific geometry with the help of Planned Dose Perturbation algorithm. The purpose of this study is to evaluate the impact of HU value of ArcCHECK phantom entered in Eclipse TPS on 3D dose & DVH QA analysis. Methods: Manufacturer of ArcCHECK phantom provides CT data set of phantom & recommends considering it as a homogeneous phantom with electron density (1.19 gm/cc or 282 HU) close to PMMA. We performed this study on Eclipse TPS (V13, VMS) & trueBEAM STx VMS Linac & ArcCHECK phantom (SNC). Plans were generated for 6MV photon beam, 20cm×20cm field size at isocentre & SPD (Source to phantom distance) of 86.7 cm to deliver 100cGy at isocentre. 3DVH software requires patients DICOM data generated by TPS & plan delivered on ArcCHECK phantom. Plans were generated in TPS by assigning different HU values to phantom. We analyzed gamma index & the dose profile for all plans along vertical down direction of beam’s central axis for Entry, Exit & Isocentre dose. Results: The global gamma passing rate (2% & 2mm) for manufacturer recommended HU value 282 was 96.3%. Detector entry, Isocentre & detector exit Doses were 1.9048 (1.9270), 1.00(1.0199) & 0.5078(0.527) Gy for TPS (Measured) respectively.The global gamma passing rate for electron density 1.1302 gm/cc was 98.6%. Detector entry, Isocentre & detector exit Doses were 1.8714 (1.8873), 1.00(0.9988) & 0.5211(0.516) Gy for TPS (Measured) respectively. Conclusion: Electron density value assigned by manufacturer does not hold true for every user. Proper modeling of electron density of ArcCHECK in TPS is essential to avoid systematic error in dose calculation of patient specific QA.

60 APPLIED LIFE SCIENCES↗

Optimization of the Shielding of a Canister Loading Machine with the deterministic Code Attila{sup R} - Paper 61

In general shielding components are designed with very conservative assumptions and boundary conditions to cover all possibly occurring situations. This often results in an overestimated shielding design in a lot of different fields of application; the shielding of components will be heavier and more expensive than needed. In most cases an initial shielding calculation in the design process shows an unbalanced shielding effect of the shielded radiation source. Sometimes the dose rate limits are slightly exceeded in several areas. From this arises a need for an optimization of the shielding structure. The goal is to decrease the radiation level in the accessible areas to keep the dose rate limits and to reduce the amount of the used shielding material if possible. Shielding material is moved from areas with higher shielding factors to which with lower ones. The optimization process is shown in an example of a loading machine for vitrified waste in canisters. The design review with an optimization of the shielding geometry was done with the deterministic code Attila{sup R} of the company Transpire, Inc. Attila{sup R} is a powerful tool to calculate and optimize the shielding effect of handling facilities for radioactive materials. It is easy to handle with its CAD integration module and an easy setup of the calculation cases. Areas with a low shielding effect which results in an exceeding of the dose rate limits can be found quickly with the illustration due to an Iso-Dose-Rate-Surface in the 3D Model. In these areas the shielding effect has to be improved. Otherwise there is material, which has no significant influence on the shielding effect and makes the handling facilities heavier and more expensive as needed. The optimization of the shielding design of the canister loading machine in the current case results in lower dose rates outside the facility to keep the dose rate limits. The demand of shielding material could be reduced and resulted in a cost reduction on the facility itself and furthermore in the caring facilities to transport this facility (cranes, etc.). (authors)

42 ENGINEERING↗