Search NASA⌕ Search

SEARCH · Search NASA

Results for “Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Sustainability assessment framework for scenarios – SAFS

To address current challenges regarding sustainable development and support planning for this form of development, new learning about different possible futures and their potential sustainability implications is needed. One way of facilitating this learning is by combining the futures studies and sustainability assessment (SA) research fields. This paper presents the sustainability assessment framework for scenarios (SAFS), a method developed for assessing the environmental and social risks and opportunities of future scenarios, provides guidelines for its application and demonstrates how the framework can be applied. SAFS suggests assessing environmental and social aspects using a consumption perspective and a life cycle approach, and provides qualitative results. SAFS does not suggest any modelling using precise data, but instead offers guidelines on how to carry out a qualitative assessment, where both the process of assessing and the outcome of the assessment are valuable and can be used as a basis for discussion. The benefits, drawbacks and potential challenges of applying SAFS are also discussed in the paper. SAFS uses systems thinking looking at future societies as a whole, considering both environmental and social consequences. This encourages researchers and decision-makers to consider the whole picture, and not just individual elements, when considering different futures. - Highlights: • The paper presents a new methodological framework for qualitative sustainability assessment of future scenarios with transformative changes. • The framework suggests qualitative assessment with consumption perspective and a life cycle approach. • The paper presents the framework and provides guidelines for its application. • The paper demonstrates on an example how the framework can be applied. • The benefits, drawbacks and challenges of the framework application and the need for further development are discussed.

54 ENVIRONMENTAL SCIENCES↗

Seven good practices for the environmental licensing of coastal interventions: Lessons from the Italian, Cuban, Spanish and Colombian regulatory frameworks and insights on coastal processes

Highlights: • Environmental licensing procedures (ELP) line up by projects instead of environments. • The ELP of four countries was compared according to the generic EIA stages. • The study relies upon the revision of EIA legislation and technical guidelines. • Seven EIA good practices were extracted from the ELP analysis of the four countries. • A changing approach is proposed for the EPL performance on coastal interventions. - Abstract: Environmental licensing is the regulatory procedure that enforces the environmental impact assessment (EIA) of human activities inside a given country. Despite worldwide acceptance of EIA as a valid tool, its application in coastal environments is still too diverse and limited regarding the specificity of the natural processes influencing the shore. This paper compares the Environmental Licensing Procedure (ELP) of four countries, focusing on the activities that could affect the coastal geomorphology. The acquisition and validation of information were done through interviews with EIA representatives in each country, who signalized the official documents of environmental licensing and coastal management to be considered in the documentary review. The results present those differences and similarities among ELP stages in each country, based on the principles of the International Association of Impact Assessment and the national documents analyzed. In sum, 59 interventions associated with human uses and activities in the coastal zone were compared according to the prescriptive character of the environmental licensing in Italy, Spain, Cuba and Colombia. The natural processes influencing coastal geomorphology were also analyzed within the technical criteria included in the official guidelines for the EIA, finding a generalized weakness in processes associated with geochemical courses on coastal environments. By way of discussion, seven good practices are illustrated, according to their pertinence to the impact assessment of the coastal zone: 1) The integration of screening and scoping; 2) Evaluation focusing on the environment rather than the intervention; 3) Binding the coastal zone delimitation; 4) Institutional articulation; 5) Accreditation of environmental consultancies; 6) Official guidelines by types of environment; 7) The integration of environmental geographic information. Finally, general conclusions to assist EIA practitioners operating in the four countries and recommendations to lead further research are provided, introducing a novel process-oriented approach for ELP.

54 ENVIRONMENTAL SCIENCES↗

Hydrotreating pine-derived catalytic fast pyrolysis oil to jet fuel: Process durability and impact of operating conditions

Hydrotreating woody biomass-derived catalytic fast pyrolysis (CFP) oil to jet fuel has the potential to enhance energy security due to the large abundance of forest and woody resources. CFP oil produced from pine over ZSM-5 was hydrotreated over sulfided NiMo/Al 2 O 3 for 410 h to study the impact of hydrotreating conditions (pressure, temperature, and weight hourly space velocity (WHSV)). The degree of deoxygenation remained high across the tested hydrotreating conditions, and the products contained < 0.01 wt% oxygen. Increasing hydrotreating pressure from 84 to 125 bar enhanced hydrogenation of aromatic rings and the formation of cycloalkanes and increasing the temperature from 385 to 400 degrees C enhanced cracking and the formation of jet-range molecules. Decreasing the weight hourly space velocity from 0.2 to 0.1 g/(g cat h) further enhanced cracking and led to higher gasoline- and lower jet fuel-range fractions. The highest jet fuel fraction (49 wt%) was obtained at 400 degrees C, 125 bar, 0.2 g/(g cat h) WHSV. CFP oils produced from pine over phosphorous-modified ZSM-5 were hydrotreated at this condition for 588 h to investigate the process durability. The hydrogenation performance of the catalyst gradually stabilized in approximately 300 h after which the product composition remained constant. Of the final hydrotreated CFP oil, 53 wt% fell in the jet fuel range with most of the tested fuel properties meeting ASTM D4054 and/or ASTM D7566 specifications. The freeze points were < -50 degrees C vs. guideline of < -40 degrees C and the viscosities at -20 degrees C were 3.8-4.1 mm 2 /s vs guideline of 8 mm 2 /s. Increasing the fraction of cycloalkanes could increase the cetane number and heating value, which did not meet the guidelines.

09 BIOMASS FUELS↗

Developing Quality Assurance Processes for Image-Guided Adaptive Radiation Therapy

Quality assurance has long been implemented in radiation treatment as systematic actions necessary to provide adequate confidence that the radiation oncology service will satisfy the given requirements for quality care. The existing reports from the American Association of Physicists in Medicine Task Groups 40 and 53 have provided highly detailed QA guidelines for conventional radiotherapy and treatment planning. However, advanced treatment processes recently developed with emerging high technology have introduced new QA requirements that have not been addressed previously in the conventional QA program. Therefore, it is necessary to expand the existing QA guidelines to also include new considerations. Image-guided adaptive radiation therapy (IGART) is a closed-loop treatment process that is designed to include the individual treatment information, such as patient-specific anatomic variation and delivered dose assessed during the therapy course in treatment evaluation and planning optimization. Clinical implementation of IGART requires high levels of automation in image acquisition, registration, segmentation, treatment dose construction, and adaptive planning optimization, which brings new challenges to the conventional QA program. In this article, clinical QA procedures for IGART are outlined. The discussion focuses on the dynamic or four-dimensional aspects of the IGART process, avoiding overlap with conventional QA guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiotherapeutic Parameters Predictive of Liver Complications Induced by Liver Tumor Radiotherapy

Purpose: The purpose of this study was to identify radiotherapeutic parameters for predicting the occurrence of liver complications induced by radiotherapy of a liver tumor. Methods and Materials: From 2001 to 2003, a total of 131 patients with hepatocellular carcinoma received three-dimensional conformal radiotherapy. The total dose was determined by the fraction of nontumor liver receiving 50% of the isocenter dose (V{sub 50%}). We evaluated three sets of published radiation dose guidelines using nontumor liver volume or a combination of nontumor liver volume and hepatic functional reserve. The V{sub 50%} was divided into three intervals (<33%, 33-66%, and >66%) and four categories (<25%, 25-49%, 50-75%, and >75%) according to guidelines by University of Michigan and the Yonsei University, respectively. According to the guideline of Cheng et al., the radiation dose was determined by the indocyanin green retention rate at 15 min (ICG-R15) and the nontumor liver volume. Results: Of the 131 patients, 13 patients (9.9%) presented with liver complications. The incidence was 11.1%, 10.3%, and 18.2%, respectively, for a V{sub 50%} of less than 33%, 33% to 66%, and more than 66%. The observed hepatic toxicity incidence was 10%, 12.1%, and 10.4% respectively for a V{sub 50%} of less than 25%, 25% to 49%, and 50% to 75%, respectively. Nontumor liver volume and ICG-R15 were not predictors of liver complications. The incidence of liver complications was significantly increased in patients with Child-Pugh Class B (p = 0.044). Conclusions: The parameter, V{sub 50%}, can be divided into 4 categories and used to predict acceptable toxicity. Furthermore, indicators of liver functional status like the Child-Pugh class may be more important and useful parameters than ICG-R15 for predicting radiation-related liver disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Randomized Double-Blind Pilot Study of Site-Specific Consensus Atlas Implementation for Rectal Cancer Target Volume Delineation in the Cooperative Group Setting

Purpose: Variations in target volume delineation represent a significant hurdle in clinical trials involving conformal radiotherapy. We sought to determine the effect of a consensus guideline-based visual atlas on contouring the target volumes. Methods and Materials: A representative case was contoured (Scan 1) by 14 physician observers and a reference expert with and without target volume delineation instructions derived from a proposed rectal cancer clinical trial involving conformal radiotherapy. The gross tumor volume (GTV), and two clinical target volumes (CTVA, including the internal iliac, presacral, and perirectal nodes, and CTVB, which included the external iliac nodes) were contoured. The observers were randomly assigned to receipt (Group A) or nonreceipt (Group B) of a consensus guideline and atlas for anorectal cancers and then instructed to recontour the same case/images (Scan 2). Observer variation was analyzed volumetrically using the conformation number (CN, where CN = 1 equals total agreement). Results: Of 14 evaluable contour sets (1 expert and 7 Group A and 6 Group B observers), greater agreement was found for the GTV (mean CN, 0.75) than for the CTVs (mean CN, 0.46-0.65). Atlas exposure for Group A led to significantly increased interobserver agreement for CTVA (mean initial CN, 0.68, after atlas use, 0.76; p = .03) and increased agreement with the expert reference (initial mean CN, 0.58; after atlas use, 0.69; p = .02). For the GTV and CTVB, neither the interobserver nor the expert agreement was altered after atlas exposure. Conclusion: Consensus guideline atlas implementation resulted in a detectable difference in interobserver agreement and a greater approximation of expert volumes for the CTVA but not for the GTV or CTVB in the specified case. Visual atlas inclusion should be considered as a feature in future clinical trials incorporating conformal RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Change in the Growth Rate of Localized Pancreatic Adenocarcinoma in Response to Gemcitabine, Bevacizumab, and Radiation Therapy on MDCT

Purpose: To depict treatment response to chemoradiotherapy by comparing tumor growth rate between treated and untreated patients and to compare depicted response with objective response according to the Response Evaluation Criteria in Solid Tumors (RECIST) 1.1 guideline. Methods and Materials: This Health Insurance Portability and Accountability Act-compliant, retrospective study was approved by the institutional review board. Volume doubling time (DT) of histologically confirmed locally advanced pancreatic adenocarcinoma was calculated in 16 patients treated with chemoradiotherapy and 10 untreated patients by incorporating interscan interval ({Delta}t) and tumor volume at baseline (V0) and follow-up (V1) obtained by semiautomated segmentation into the following equation: DT = {Delta}t . log 2/log (V1/V0). Reciprocal of doubling time (RDT), which is the linear representation of tumor growth rate, was calculated by use of the following equation: RDT = 365/DT. The lowest RDT value of 2.42 in untreated patients was considered as the cutoff value for depiction of treatment response. Depicted response rate was defined as the proportion of patients with an RDT value of less than 2.42. Depicted response was compared with objective response according to the RECIST 1.1 guideline. The significance level was set at p < 0.05. Results: There was a significant difference in mean RDT between treated (range, -7.12 to 3.27; mean, -1.27; median, -1.30) and untreated (range, 2.42 to 10.74; mean, 5.33; median, 4.26) patients (p < 0.05). Reciprocal of doubling time was less than 2.42 in 14 treated patients, which corresponded to a depicted response rate of 87.50% as opposed to the objective response rate of 18.75% according to the RECIST 1.1 guideline (p < 0.05) and carbohydrate antigen 19-9 response rate of 62.50% (p > 0.05). Carbohydrate antigen 19-9 response was concordant with RDT and RECIST response in 12 patients (75.00%) ({kappa}, 0.38) and 9 patients (56.25%) ({kappa}, 0.24), respectively. Conclusions: There was a significant difference between depicted response according to RDT and objective response according to RECIST. Reciprocal of doubling time might serve as a valuable biomarker for evaluation of treatment response when depiction of small changes in tumor size is concerned.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radioembolization for Neuroendocrine Liver Metastases: Safety, Imaging, and Long-Term Outcomes

Purpose: To present long-term outcomes on the safety and efficacy of Yttrium-90 radioembolization in the treatment of unresectable hepatic neuroendocrine metastases refractory to standard-of-care therapy. Methods and Materials: This study was approved by our institutional review board and was compliant with the Health Insurance Portability and Accountability Act. Forty patients with hepatic neuroendocrine metastases were treated with {sup 90}Y radioembolization at a single center. Toxicity was assessed using National Cancer Institute Common Terminology Criteria v3.0. Response to therapy was assessed by World Health Organization (WHO) guidelines for size and European Association for the Study of the Liver disease (EASL) guidelines for necrosis. Time to response and overall survival were calculated using the Kaplan-Meier method. Univariate and multivariate analyses were performed. Results: The median dose was 113 Gy (29-299 Gy). Clinical toxicities included fatigue (63%), nausea/vomiting (40%), abdominal pain (18%), fever (8%), diarrhea and weight loss (5%); Grade 3 and 4 bilirubin toxicities were experienced by 2 patients and 1 patient, respectively. Different responses were noted by WHO (complete response, 1.2%; partial response, 62.7%) and EASL (complete response, 20.5%; partial response, 43.4%). Median time to response was 4 and 4.9 months by lesion and patient, respectively. The 1-, 2-, and 3-year overall survival rates were 72.5%, 62.5%, and 45%, respectively. Eastern Cooperative Oncology Group (ECOG) performance score 0 (p < 0.0001), tumor burden {<=}25% (p = 0.0019), albumin {>=}3.5 g/dL (p = 0.017), and bilirubin {<=}1.2 mg/dL (p = 0.002) prognosticated survival on univariate analysis; only ECOG performance score 0 and bilirubin {<=}1.2 mg/dL prognosticated better survival outcome on multivariate analysis (p = 0.0001 and p = 0.02). Conclusion: Yttrium-90 therapy for hepatic neuroendocrine metastases leads to satisfactory tumor response and patient survival with low toxicity, in line with published national guidelines recommending radioembolization as a potential option for unresectable hepatic neuroendocrine metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postoperative Radiotherapy in Prostate Cancer: The Case of the Missing Target

Purpose: Postoperative radiotherapy (XRT) increases survival in high-risk prostate cancer patients. Approximately 50% of patients on long-term follow-up relapse despite adjuvant XRT and the predominant site of failure remains local. Four consensus guidelines define postoperative clinical target volume (CTV) in prostate cancer. We explore the possibility that inadequate CTV coverage is an important cause of local failure. This study evaluates the utility of preoperative magnetic resonance imaging (MRI) in defining prostate bed CTV. Methods and Materials: Twenty prostate cancer patients treated with postoperative XRT who also had preoperative staging MRI were included. The four guidelines were applied and the CTVs were expanded to create planning target volumes (PTVs). Preoperative MRIs were fused with postoperative planning CT scans. MRI-based prostate and gross visible tumors were contoured. Three-dimensional (3D) conformal four- and six-field XRT plans were developed and dose-volume histograms analyzed. Subtraction analysis was conducted to assess the adequacy of prostate/gross tumor coverage. Results: Gross tumor was visible in 18 cases. In all 20 cases, the consensus CTVs did not fully cover the MRI-defined prostate. On average, 35% of the prostate volume and 32% of the gross tumor volume were missed using six-field 3D treatment plans. The entire MRI-defined gross tumor volume was completely covered in only two cases (six-field plans). The expanded PTVs did not cover the entire prostate bed in 50% of cases. Prostate base and mid-zones were the predominant site of inadequate coverage. Conclusions: Current postoperative CTV guidelines do not adequately cover the prostate bed and/or gross tumor based on preoperative MRI imaging. Additionally, expanded PTVs do not fully cover the prostate bed in 50% of cases. Inadequate CTV definition is likely a major contributing factor for the high risk of relapse despite adjuvant XRT. Preoperative imaging may lead to more accurate CTV definition, which should result in further improvements in survival for patients with high-risk prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemoradiotherapy of Anal Carcinoma: Survival and Recurrence in an Unselected National Cohort

Purpose: To evaluate treatment results, elucidate whether national guidelines were followed, and identify areas demanding further treatment optimization. Methods and Material: Between July 2000 and June 2007, 328 patients were treated with curatively intended chemoradiotherapy (CRT) for nonmetastatic squamous cell carcinoma of the anal region, according to national treatment guidelines based on tumor stage. Results: Complete response after CRT was obtained in 87% of patients, rising to 93% after salvage surgery. Chemotherapy, elective irradiation of the groin and salvage surgery were performed to a lesser extent in elderly patients, mainly because of frailty and comorbidity. Recurrence occurred in 24% of the patients, resulting in a 3- and 5-year recurrence-free survival (RFS) of 79% and 74%, respectively. Locoregional recurrences dominated, most commonly in the primary tumor site. Recurrence was treated with curative intent in 45% of the cases. The 3- and 5-year overall survival were 79% and 66%, and cancer-specific survival (CSS) were 84% and 75%, respectively. The risk of adverse outcome increased significantly with more locally advanced tumors and for male gender in multivariable analyses for RFS and CSS. Conclusions: The treatment results are in accordance with similar cohorts. The primary treatment control rate was high, but there was a significant risk of locoregional recurrence in advanced tumors. The loyalty to national guidelines was broad, although individual adjustments occurred. However, caution to avoid toxicity must not lead to inadequate treatment. Male gender seems to have inferior outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results of a Quality Assurance Review of External Beam Radiation Therapy in the International Society of Paediatric Oncology (Europe) Neuroblastoma Group's High-risk Neuroblastoma Trial: A SIOPEN Study

Purpose: Radiation therapy is important for local control in neuroblastoma. This study reviewed the compliance of plans with the radiation therapy guidelines of the International Society of Paediatric Oncology (Europe) Neuroblastoma Group (SIOPEN) High-Risk Trial protocol. Methods and Materials: The SIOPEN trial central electronic database has sections to record diagnostic imaging and radiation therapy planning data. Individual centers may upload data remotely, but not all centers involved in the trial chose to use this system. A quality scoring system was devised based on how well the radiation therapy plan matched the protocol guidelines, to what extent deviations were justified, and whether adverse effects may result. Central review of radiation therapy planning was undertaken retrospectively in 100 patients for whom complete diagnostic and treatment sets were available. Data were reviewed and compared against protocol guidelines by an international team of radiation oncologists and radiologists. For each patient in the sample, the central review team assigned a quality assurance score. Results: It was found that in 48% of patients there was full compliance with protocol requirements. In 29%, there were deviations for justifiable reasons with no likely long-term adverse effects resulting. In 5%, deviations had occurred for justifiable reasons, but that might result in adverse effects. In 1%, there was a deviation with no discernible justification, which would not lead to long-term adverse events. In 17%, unjustified deviations were noted, with a risk of an adverse outcome resulting. Conclusions: Owing to concern over the proportion of patients in whom unjustified deviations were observed, a protocol amendment has been issued. This offers the opportunity for central review of radiation therapy plans before the start of treatment and the treating clinician a chance to modify plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A two-dimensional analytical unit cell model for redox flow battery evaluation and optimization

Cell performance optimization is important for improving the overall system efficiency of a redox flow battery. To gain better insights into key controlling factors of system efficiency, this work first proposed a theoretical model for a unit flow battery cell by extending a two-dimensional analytic model to a full battery cell. Such a model is then used for cell performance optimization after validating it with experimental and numerical modeling data. With the model results, the activation, equilibrium, and pump energy losses are identified as the dominant sources of battery energy losses. Further, a guideline for reducing these sources is also proposed. Following the guideline, the mass transport coefficient is shown as a key control factor of the equilibrium energy loss and Coulombic efficiency (CE). Approaches are then proposed to improve CE and the overall system efficiency. The mass transport is also revealed as the mechanism of pump rate optimization where an optimal pump rate significantly reduces the equilibrium energy loss. With both low equilibrium and pump energy losses, an optimal electrode porosity or specific area design can further improve a battery's system efficiency based on an optimal porosity predicted by the present model. The model also demonstrates distinct behaviors and overestimation in the system efficiency when reduced to a zero-dimensional model with neglected mass transport resistance. With the new model, the guideline, and new insights, this work provides a reliable and efficient tool for the evaluation and optimization of redox flow battery design in practical applications.

25 ENERGY STORAGE↗

Higher than expected N 2 O emissions from soybean crops in the Pampas Region of Argentina: Estimates from DayCent simulations and field measurements

In developing countries, agriculture generally represents a large fraction of GHG emissions reported in National Inventories, and emissions are typically estimated using Tier 1 IPCC guidelines. However, field data and locally adapted simulation models can improve the accuracy of IPCC estimations. In this report we aimed to quantify anthropogenic N2O emissions from croplands of Argentina through field measurements, model simulations and IPCC guidelines. Here we measured N 2 O emissions and their controlling factors in 62 plots of the Pampas Region with corn, soybean and wheat/soybean crops and in unmanaged grasslands. We accounted for gross emissions from crops and background emissions from unmanaged grasslands to calculate net anthropogenic emissions from crops as the difference between them. We calibrated and evaluated the DayCent model and then simulated different weather and management scenarios. Finally, we applied IPCC guidelines to estimate anthropogenic N 2 O emissions at the same plots. The DayCent model accurately simulated annual N 2 O emission for all crops as compared to measured data (RMSE = 1.4 g N ha -1 day -1 ). Measured and simulated emissions in soybean crops were higher than in corn and wheat/soybean crops. Gross N 2 O emissions ranged from 1.4 to 5.1 kg N ha -1 yr -1 for current environmental (soil and weather) and management (crops and fertilizer doses) conditions. Background emissions ranged between 1.1 and 1.3 kg N ha -1 yr -1 , and therefore net anthropogenic emissions ranged from 0.3 to 4.0 kg N ha-1 yr -1 . IPCC Tier 1 emission factors underestimated N2O releases from soybean, that were on average 4.87 times greater when estimated with DayCent and observations (0.53 vs 2.47 and 2.69 kg N ha -1 yr -1 , respectively). On the contrary, IPCC estimates for corn and wheat/soybean crops were similar to modeled and measured values. Our results suggest that N 2 O emissions from the vast 15 million ha of soybean croplands in the Pampas Region may be substantially underestimated.

59 BASIC BIOLOGICAL SCIENCES↗

Approaches to cancer assessment in EPA's Integrated Risk Information System

The U.S. Environmental Protection Agency's (EPA) Integrated Risk Information System (IRIS) Program develops assessments of health effects that may result from chronic exposure to chemicals in the environment. The IRIS database contains more than 540 assessments. When supported by available data, IRIS assessments provide quantitative analyses of carcinogenic effects. Since publication of EPA's 2005 Guidelines for Carcinogen Risk Assessment, IRIS cancer assessments have implemented new approaches recommended in these guidelines and expanded the use of complex scientific methods to perform quantitative dose-response assessments. Two case studies of the application of the mode of action framework from the 2005 Cancer Guidelines are presented in this paper. The first is a case study of 1,2,3-trichloropropane, as an example of a chemical with a mutagenic mode of carcinogenic action thus warranting the application of age-dependent adjustment factors for early-life exposure; the second is a case study of ethylene glycol monobutyl ether, as an example of a chemical with a carcinogenic action consistent with a nonlinear extrapolation approach. The use of physiologically based pharmacokinetic (PBPK) modeling to quantify interindividual variability and account for human parameter uncertainty as part of a quantitative cancer assessment is illustrated using a case study involving probabilistic PBPK modeling for dichloromethane. We also discuss statistical issues in assessing trends and model fit for tumor dose-response data, analysis of the combined risk from multiple types of tumors, and application of life-table methods for using human data to derive cancer risk estimates. These issues reflect the complexity and challenges faced in assessing the carcinogenic risks from exposure to environmental chemicals, and provide a view of the current trends in IRIS carcinogenicity risk assessment.

60 APPLIED LIFE SCIENCES↗

Tools and Incentives for Implementing Codes of Ethics to Help Prevent the Reemergence of Chemical Weapons

Since the entry into force of the Chemical Weapons Convention (CWC) and the establishment of the Organisation for Prohibition of Chemical Weapons (OPCW) in 1997, 96% of the world’s declared stockpile, comprising 72,305 metric tons of chemical warfare agents have been destroyed. Despite this notable progress, the convergence of chemistry and biology brings new challenges to preventing chemical weapons production, as the technical capability to manipulate the chemistry of microorganisms has diffused beyond the chemical industry and academic research communities. The development and voluntary adoption by chemical practitioners around the world of ethical codes or guidelines, such as The Hague Ethical Guidelines and the Global Chemists’ Code of Ethics (GCCE) , are important steps in strengthening international nonproliferation efforts through their potential to impact the intent of the individual by normalizing ethical behavior. However, the simple act of adopting a code does not guarantee ethical behavior. Care must be taken to ensure those adopting the code understand specifically the behavior being asked of them, and they must be given ample opportunities to practice exercising those behaviors in low-risk situations and encouragement to keep trying when they fail. Furthermore, in small-to-medium chemical companies, concerns that adopting such measures could negatively impact profit margins may dissuade some business owners from voluntarily adopting ethical codes, while a country’s decision makers may not prioritize establishment of new regulatory mechanisms that could address some of these concerns. In this paper, factors that may positively influence a chemical company’s decision to adopt ethical guidelines, such as integration of social sustainability elements into frameworks and approaches to maintain social legitimacy in the eyes of the broader community, are explored. Voluntary adoption of ethical codes gives teeth to arms control regimes. By encouraging chemical companies to become engaged in the community around them and providing easy-to-use tools like scenario-based E-learning to enable remote engagement and facilitate understanding of the principles undergirding the GCCE, they actively participate in making the world a better place and minimizing the potential for reemergence of chemical weapons.

Small Chemical Companies, Codes of Ethics, E-learn↗

Management of Naturally Occurring Radioactive Materials (NORM) in Canada

In Canada, nuclear and radiological regulatory responsibilities are shared between the provinces/territories and the federal government. The Canadian Nuclear Safety Commission (CNSC) regulates nuclear fuel cycle materials and man-made radionuclides under the Nuclear Safety and Control Act (2000). The provinces and territories regulate NORM arising from industrial activities, not involving the nuclear fuel cycle materials. Present guideline--Canadian Guidelines for the Management of Naturally Occurring Radioactive Materials (NORM)--was published in 2000 in order to bring uniformity to the management of NORM-related procedures to provide adequate radiation protection for workers and the general public. The basic premise of these guidelines is that the NORM-related activities should not be posing any greater hazard than those activities regulated under the Nuclear Safety and Control Act; these concepts are described in this paper.

54 ENVIRONMENTAL SCIENCES↗

Modelling and mitigating dose to firefighters from inhalation of radionuclides in wildland fire smoke

Firefighters responding to wildland fires where surface litter and vegetation contain radiological contamination will receive a radiological dose by inhaling resuspended radioactive material in the smoke. This may increase their lifetime risk of contracting certain types of cancer. Using published data, we modelled hypothetical radionuclide emissions, dispersion and dose for 70th and 97th percentile environmental conditions and for average and high fuel loads at the Savannah River Site. We predicted downwind concentration and potential dose to firefighters for radionuclides of interest ( 137 Cs, 238 Pu, 90 Sr and 210 Po). Predicted concentrations exceeded dose guidelines in the base case scenario emissions of 1.0 × 10 7 Bq ha –1 for 238 Pu at 70th percentile environmental conditions and average fuel load levels for both 4- and 14-h shifts. Under 97th percentile environmental conditions and high fuel loads, dose guidelines were exceeded for several reported cases for 90 Sr, 238 Pu and 210 Po. Potential for exceeding dose guidelines was mitigated by including plume rise (>2 m s –1 ) or moving a small distance from the fire owing to large concentration gradients near the edge of the fire. As a result, our approach can quickly estimate potential dose from airborne radionuclides in wildland fire and assist decision-making to reduce firefighter exposure.

60 APPLIED LIFE SCIENCES↗

Some Considerations for Chelation Treatment and Surgical Excision Following Incorporation of Plutonium in Wounds

After a plutonium-contaminated wound, the role of an internal dosimetrist is to inform the patient and the physician of the dosimetric considerations. The doses averted due to medical treatments (excision or chelation) are higher if the treatments are administered early; therefore, the internal dosimetrist needs to rely on limited information on wound counts and process knowledge for advising the physician. For this study, several wound cases in the literature were reviewed to obtain estimates of the efficacies of surgical excision and chelation treatment after plutonium-contaminated wounds. The dose coefficients calculated by coupling the NCRP 156 wound model with the systemic model were used to derive the decision guidelines that may indicate medical treatment based on 1) the concept of saved doses proposed by the NCRP 156 wound model, 2) the limits recommended by the CEC/DOE guidebook, and 3) the Clinical Decision Guidelines proposed in NCRP Report No. 161. These guidelines by themselves, however, are of limited use for several reasons, including 1) large uncertainties associated with wound measurements, 2) exposure to forms of radionuclides that cannot be assigned to a single category in the NCRP 156 framework, 3) inability of the NCRP 156 model to explain some of the wound cases in the literature, 4) neglect of the local doses to the wound site and the pathophysiological response of the tissue, 5) poorly understood relationship between effective doses and risks of late health effects, and 6) disregard of the psychological aspects of radionuclide intake.

61 RADIATION PROTECTION AND DOSIMETRY↗