Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image analysis.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Circular orientation fluorescence emitter imaging (COFEI) of rotational motion of motor proteins

Single-molecule fluorescence polarization technique has been utilized to detect structural changes in biomolecules and intermolecular interactions. Here we developed a single-molecule fluorescence polarization measurement system, named circular orientation fluorescence emitter imaging (COFEI), in which a ring pattern of an acquired fluorescent image (COFEI image) represents an orientation of a polarization and a polarization factor. Rotation and pattern change of the COFEI image allow us to find changes in the polarization by eye and further values of the parameters of a polarization are determined by simple image analysis with high accuracy. We validated its potential applications of COFEI by three assays: 1) Detection of stepwise rotation of F{sub 1}-ATPase via single quantum nanorod attached to the rotary shaft γ; 2) Visualization of binding of fluorescent ATP analog to the catalytic subunit in F{sub 1}-ATPase; and 3) Association and dissociation of one head of dimeric kinesin-1 on the microtubule during its processive movement through single bifunctional fluorescent probes attached to the head. These results indicate that the COFEI provides us the advantages of the user-friendly measurement system and persuasive data presentations.

60 APPLIED LIFE SCIENCES↗

Effects of Vanadium on Modification of Iron-Rich Intermetallics and Mechanical Properties in A356 Cast Alloys with 1.5 wt.% Fe

Formation of Fe-rich intermetallics and mechanical properties of vanadium-modified A356 cast alloys with 1.5 wt.% Fe were investigated using image analysis, scanning electron microscopy, differential scanning calorimetry, and a tensile test. The results showed that V content has no apparent influence on α-Al grain size in A356 alloys with high Fe content. Also, 0.8 wt.% V is beneficial for improving mechanical properties in A356 cast alloys with high Fe content. Specifically, these results can be attributed to the formation of Chinese script or block α-Fe phases, refined needle-like β-Fe (Al{sub 5}FeSi), and decreased porosities. An excessive amount of V deteriorates mechanical properties of alloys because it leads to VSi{sub 2} formation, large sized iron-rich intermetallics, and increased porosities.

36 MATERIALS SCIENCE↗

Growth kinetics of Al–Fe intermetallic compounds during annealing treatment of friction stir lap welds

In this study, we explored the growth kinetics of the Al–Fe intermetallic (IM) layer at the joint interface of the St-12/Al-5083 friction stir lap welds during post-weld annealing treatment at 350, 400 and 450 °C for 30 to 180 min. Optical microscope (OM), field emission gun scanning electron microscope (FEG-SEM) and transmission electron microscope (TEM) were employed to investigate the structure of the weld zone. The thickness and composition of the IM layers were evaluated using image analysis system and electron back-scatter diffraction (EBSD), respectively. Moreover, kernel average misorientation (KAM) analysis was performed to evaluate the level of stored energy in the as-welded state. The results showed that the growth kinetics of the IM layer was not governed by a parabolic diffusion law. Presence of the IM compounds as well as high stored energy near the joint interface of the as-welded sample was recognized to be the origin of the observed deviation from the parabolic diffusion law. - Highlights: • This work provided a new insight into growth kinetics of Al–Fe IM thickness. • The growth kinetics of IM layer was not governed by a parabolic diffusion law. • IM near the joint interface was the origin of deviation from the parabolic law. • High stored energy at joint interface was origin of deviation from parabolic law.

36 MATERIALS SCIENCE↗

Impact load-induced micro-structural damage and micro-structure associated mechanical response of concrete made with different surface roughness and porosity aggregates

The relationship between the nature of micro damage under impact loading and changes in mechanical behavior associated with different microstructures is studied for concretes made with two different coarse aggregates having significant differences mainly in roughness and porosity - sintered fly ash and uncrushed gravel. A range of techniques including X-ray diffraction, digital image analysis, mercury porosimetry, X-ray computed tomography, laser surface profilometry and scanning electron microscopy were used to characterize the aggregates and micro-structures. The concrete prepared with lightweight aggregates was stronger in compression than the gravel aggregate concrete due to enhanced hydration as a result of internal curing. In the lightweight concrete, it was deduced that an inhomogeneous micro-structure led to strain incompatibilities and consequent localized stress concentrations in the mix, leading to accelerated failure. The pore structure, compressibility, and surface texture of the aggregates are of paramount importance for the micro-cracking growth.

36 MATERIALS SCIENCE↗

Determining the water-cement ratio, cement content, water content and degree of hydration of hardened cement paste: Method development and validation on paste samples

We propose a new method to estimate the initial cement content, water content and free water/cement ratio (w/c) of hardened cement-based materials made with Portland cements that have unknown mixture proportions and degree of hydration. This method first quantifies the composition of the hardened cement paste, i.e. the volumetric fractions of capillary pores, hydration products and unreacted cement, using high-resolution field emission scanning electron microscopy (FE-SEM) in the backscattered electron (BSE) mode and image analysis. From the obtained data and the volumetric increase of solids during cement hydration, we compute the initial free water content and cement content, hence the free w/c ratio. The same method can also be used to calculate the degree of hydration. The proposed method has the advantage that it is quantitative and does not require comparison with calibration graphs or reference samples made with the same materials and cured to the same degree of hydration as the tested sample. This paper reports the development, assumptions and limitations of the proposed method, and preliminary results from Portland cement pastes with a range of w/c ratios (0.25-0.50) and curing ages (3-90 days). We also discuss the extension of the technique to mortars and concretes, and samples made with blended cements.

36 MATERIALS SCIENCE↗

MO-F-CAMPUS-J-05: Using 2D Relative Gamma Analysis From EPID Image as a Predictor of Plan Deterioration Due to Anatomical Changes

Purpose: One of the side effects of radiotherapy for head and neck (H&N) cancer is the patient’s anatomical changes. The changes can strongly affect the planned dose distribution. In this work, our goal is to demonstrate that relative analysis of EPID images is a fast and simple method to detect anatomical changes that can have a strong dosimetric impact on the treatment plan for H&N patients. Methods: EPID images were recorded at every beam and all fractions for 50 H&N patients. Of these, five patients that showed important anatomical changes were selected to evaluate dosimetric impacts of these changes and to correlate them with a 2D relative gamma analysis of EPID images. The planning CT and original contours were deformed onto CBCTs (one mid treatment and one at the end of treatment). By using deformable image registration, it was possible to map accurate CT numbers from the planning CT to the anatomy of the day obtained with CBCTs. Clinical treatment plan were then copied on the deformed dataset and dose was re-computed. In parallel, EPID images were analysed using the gamma index (3%3mm) relative to the first image. Results: It was possible to divide patients in two distinct, statistically different (p<0.001) categories using an average gamma index of 0.5 as a threshold. Below this threshold no significant dosimetric degradation of the plan are observed. Above this threshold two types of plan deterioration were seen: (1) target dose increases, but coverage remains adequate while dose to at least one OAR increases beyond tolerances; (2) the OAR doses remain low, but the target dose is reduced and coverage becomes inadequate. Conclusion: Relative analysis gamma of EPID images could indeed be a fast and simple method to detect anatomical changes that can potentially deteriorates treatment plan for H&N patients. This work was supported in part by Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Interstitial Fluid Pressure and Vascularity of Intradermal and Intramuscular Human Tumor Xenografts

Purpose: High interstitial fluid pressure (IFP) in tumors has been shown to be associated with poor prognosis. Mechanisms underlying the intertumor heterogeneity in IFP were investigated in this study. Methods and Materials: A-07 melanoma xenografts were transplanted intradermally or intramuscularly in BALB/c nu/nu mice. IFP was measured in the center of the tumors with a Millar catheter. Tumor blood perfusion and extracellular volume fraction were assessed by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). The necrotic fraction, vascular density, and vessel diameters of the tumors were determined by image analysis of histological preparations. Results: Significant intertumor heterogeneity in IFP, blood perfusion, and microvascular morphology was observed whether the tumors were transplanted intradermally or intramuscularly. High IFP was mainly a consequence of high resistance to blood flow caused by low vessel diameters in either transplantation site. IFP decreased with increasing blood perfusion in intradermal tumors and increased with increasing blood perfusion in intramuscular tumors, mainly because the morphology of the tumor microvasculature differed systematically between the two tumor models. Conclusion: The potential of DCE-MRI as a noninvasive method for assessing the IFP of tumors may be limited because any relationship between IFP and blood perfusion may differ with the tumor growth site.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Resolution Electron Microscopy and Kinetic Studies of Precipitation Hardening Reactions in Cast Al-5.8Zn-2.2Mg-2.5Cu

Precipitation age hardening (T6) response of Al-5.8Zn-2.2Mg-2.5Cu alloy in near-net-shaped cast condition was investigated. Cast samples were manufactured using the controlled diffusion solidification (CDS) technology combined with a metallic mold tilt pour gravity casting process. This study was conducted using (1) non-isothermal aging during differential scanning calorimetry (DSC) experiments and (2) isothermal aging during which transient bulk and micro-hardness measurements taken at four aging temperatures of 343, 393, 433 and 473 K. A detailed microstructural investigation combined with a quantitative image analysis was carried out on both DSC and hardness specimens using high-resolution electron microscopy (HREM) and energy-dispersive spectroscopy (EDS) elemental mappings. Hardness measurements were analyzed using a kinetic modeling approach (single state variable combined with a kinetic equation that is valid for the Al-Zn-Mg-Cu alloys). The results confirm the formation of hardening phases of GP zone, intermediate hardening metastable phase η′ and equilibrium phase η. The results of calorimetric measurements, electron microscopy and selected area diffraction patterns are in good agreement and confirm transient precipitation/dissolution sequences. A mean value of activation energy Q{sub A} of 75 kJ/mol was evaluated for combined bulk diffusion rate of alloying elements during precipitation of strengthening phases within Al matrix.

36 MATERIALS SCIENCE↗

37 NEW T-TYPE BROWN DWARFS IN THE CANADA-FRANCE BROWN DWARFS SURVEY

The Canada-France Brown Dwarfs Survey is an i'- and z'-band survey realized with MegaCam at the Canada-France-Hawaii Telescope that covers a surface area of 780 deg{sup 2}. Image analysis is now completed while J-band follow-up campaigns are {approx}90% done. The survey identified about 70 T dwarf candidates, of which 43 now have near-infrared spectra obtained with NIRI and GNIRS at Gemini and ISAAC at the Very Large Telescope. Six of these were previously published and we present here the 37 new discoveries, all T dwarfs. They range from T0 to T8.5 with four being of type T7 or later. Both newly identified T8 dwarfs are possibly high log (g) massive brown dwarfs of thin disk age. One T4.5 dwarf shows signs of sub-metallicity. We present proper motions and near-infrared photometry, and discuss about the most peculiar/interesting objects in some details.

79 ASTRONOMY AND ASTROPHYSICS↗

Controlling melt flow by nanoparticles to eliminate surface wave induced surface fluctuation

The high surface roughness is one of the major challenges encountered in laser metal additive manufacturing (AM) processes, which is closely related to the melt flow behavior. However, how to control the melt flow in laser metal AM processes to improve surface finish is unknown. Here we reveal the effects of nanoparticles on melt flow behavior at every location of melt pool during laser metal AM process for the first time using Al6061 + TiC nanoparticles system and achieve significant improvement of surface finish by using TiC nanoparticles to control the melt flow and damp the surface wave. Based on the in-situ x-ray imaging observation, the surface wave is fully damped after adding TiC nanoparticles, compared with only 56% damping without nanoparticles during LPBF of Al6061. Our in-depth in-situ x-ray imaging analysis and viscosity measurement enable us to identify that nanoparticle-induced increase of viscosity causes the fully damping of the surface wave by (1) increasing the internal fluid friction for more efficient wave amplitude reduction, (2) controlling the melt flow to increase the surface wave number, (3) controlling the melt flow to increase the wave damping time. Furthermore, we also quantified the relative contributions of increasing fluid friction, increasing wave number, and increasing damping time to wave damping, which account for 61%, 25%, and 14%, respectively. Furthermore, our research provides the mechanisms and potential method to address the surface finish challenge in laser metal AM processes.

36 MATERIALS SCIENCE↗

Tooth Whitening And Temperature Rise With Two Bleaching Activation Methods

To measure the tooth whitening and the surface and Intrapulpal temperature increase in vitro on freshly extracted upper human central incisors after chemical, Zoom AP light and diode laser activated bleaching. Thirty caries-free upper human incisors were selected. Teeth were divided into three equal groups according to the methods of activation of the bleaching agent (n = 10). A whitening gel containing hydrogen peroxide was applied to the buccal surface of all teeth. Group I was bleached using chemically activated hydrogen peroxide gel, for three applications of 15 min each. Group II was bleached with high intensity advanced power Zoom activation light (Zoom AP), for three applications of 15 min each. Group III was bleached with diode laser activation technique, where the teeth were irradiated with 2 Watt diode laser for three applications of 30 sec each. The whitening degree was assessed using an image analysis system, while temperature rise was recorded using a thermocouple on the external tooth surface and Intrapulpal. The degree of whitening increased significantly in all groups. However, the percentage of whitening was not statistically significantly different between the three groups. In addition, group II showed statistically significant higher mean rise in both surface and pulp temperatures than group I and group III. Chemical bleaching produces the same whitening effect as Zoom AP light and laser, with no surface or pulpal temperature rise. Laser application is faster and produces less surface and pulp temperature increase than Zoom AP light. Diode laser used to activate bleaching gels is not considered dangerous to the vitality of dental pulp using power settings of 2 W.

36 MATERIALS SCIENCE↗

Designing Pulse Laser Surface Modification of H13 Steel Using Response Surface Method

This paper presents a design of experiment (DOE) for laser surface modification process of AISI H13 tool steel in achieving the maximum hardness and minimum surface roughness at a range of modified layer depth. A Rofin DC-015 diffusion-cooled CO{sub 2} slab laser was used to process AISI H13 tool steel samples. Samples of 10 mm diameter were sectioned to 100 mm length in order to process a predefined circumferential area. The parameters selected for examination were laser peak power, overlap percentage and pulse repetition frequency (PRF). The response surface method with Box-Behnken design approach in Design Expert 7 software was used to design the H13 laser surface modification process. Metallographic study and image analysis were done to measure the modified layer depth. The modified surface roughness was measured using two-dimensional surface profilometer. The correlation of the three laser processing parameters and the modified surface properties was specified by plotting three-dimensional graph. The hardness properties were tested at 981 mN force. From metallographic study, the laser modified surface depth was between 37 {mu}m and 150 {mu}m. The average surface roughness recorded from the 2D profilometry was at a minimum value of 1.8 {mu}m. The maximum hardness achieved was between 728 and 905 HV{sub 0.1}. These findings are significant to modern development of hard coatings for wear resistant applications.

36 MATERIALS SCIENCE↗

Ultra-Fine Grain Structures Of Model Al-Mg-Si Alloys Produced By Hydrostatic Extrusion

Microstructure and mechanical properties were studied in model Al-Mg-Si alloys (Al-1 % Mg-0.8% Si and Al-0.5% Mg-0.3% Si-wt %) deformed by hydrostatic extrusion (HE) to strains of 1.4 and 3.8. In these alloys the different percentage of two hardening second-phase precipitates (Mg{sub 2}Si and Si) were observed. The microstructure was characterized by transmission electron microscopy and optical microscopy. The microstructure of the alloys in the initial state was built of coarse grains of an average diameter of {approx}30 rim. The refined microstructure was examined qualitatively and quantitatively using the stereological method and a computer image analysis. The deformation-processed structures evolved very rapidly, forming ultrafine grained (UFG) materials with grains of about 0.4 {mu}m. In addition, the grain refinement in the HE-treated materials has a substantial effect on their properties, such as the mechanical strength and micro-hardness which increase significantly. It has been found that, after {epsilon} = 3.8 in the Al-1% Mg-0.8% Si alloy, the micro-hardness increases approximately twofold. The yield stress is more than four times higher in the UFG alloys, in comparison to the initial state. Similar results were identified in the Al-0.5% Mg-0.3% Si. This is due to the very rapid refinement of the microstructure during the deformation and presence of second-phase particles.

36 MATERIALS SCIENCE↗

WE-A-17A-09: Exploiting Electromagnetic Technologies for Real-Time Seed Drop Position Validation in Permanent Implant Brachytherapy

Purpose: To report on preliminary results validating the performance of a specially designed LDR brachytherapy needle prototype possessing both electromagnetic (EM) tracking and seed drop detection abilities. Methods: An EM hollow needle prototype has been designed and constructed in collaboration with research partner Philips Healthcare. The needle possesses conventional 3D tracking capabilities, along with a novel seed drop detection mechanism exploiting local changes of electromagnetic properties generated by the passage of seeds in the needle's embedded sensor coils. These two capabilities are exploited by proprietary engineering and signal processing techniques to generate seed drop position estimates in real-time treatment delivery. The electromagnetic tracking system (EMTS) used for the experiment is the NDI Aurora Planar Field Generator. The experiment consisted of dropping a total of 35 seeds in a prismatic agarose phantom, and comparing the 3D seed drop positions of the EMTS to those obtained by an image analysis of subsequent micro-CT scans. Drop position error computations and statistical analysis were performed after a 3D registration of the two seed distributions. Results: Of the 35 seeds dropped in the phantom, 32 were properly detected by the needle prototype. Absolute drop position errors among the detected seeds ranged from 0.5 to 4.8 mm with mean and standard deviation values of 1.6 and 0.9 mm, respectively. Error measurements also include undesirable and uncontrollable effects such as seed motion upon deposition. The true accuracy performance of the needle prototype is therefore underestimated. Conclusion: This preliminary study demonstrates the potential benefits of EM technologies in detecting the passage of seeds in a hollow needle as a means of generating drop position estimates in real-time treatment delivery. Such tools could therefore represent a potentially interesting addition to existing brachytherapy protocols for rapid dosimetry validation. Equipments and fundings for this project were provided by Philips Medical.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mass balance investigation of alpine glaciers through LANDSAT TM data

An analysis of LANDSAT Thematic Mapper (TM) data of the Pasterze Glacier and the Kleines Fleisskees in the Austrian Alps was undertaken and compared with meteorological data of nearby weather stations. Alpine or valley glaciers can be used to study regional and worldwide climate changes. Alpine glaciers respond relatively fast to a warming or cooling trend in temperature through an advance or a retreat of the terminus. In addition, the mass balance of the glacier is being affected. Last year two TM scenes of the Pasterze Glacier of Aug. 1984 and Aug. 1986 were used to study the difference in reflectance. This year, in addition to the scenes from last year, one MSS scene of Aug. 1976 and a TM scene from 1988 were examined for both the Pasterze Glacier and the Kleines Fleisskees. During the overpass of the LANDSAT on 6 Aug. 1988 ground truthing on the Pasterze Glacier was undertaken. The results indicate that there was considerable more reflectance in 1976 and 1984 than in 1986 and 1988. The climatological data of the weather stations Sonnblick and Rudolfshuette were examined and compared with the results found through the LANDSAT data. There were relations between the meteorological and LANDSAT data: the average temperature over the last 100 years showed an increase of .4 C, the snowfall was declining during the same time period but the overall precipitation did not reveal any significant change over the same period. With the use of an interactive image analysis computer, the LANDSAT scenes were studied. The terminus of the Pasterze Glacier retreated 348 m and the terminus of the Kleines Fleisskees 121 m since 1965. This approach using LANDSAT MSS and TM digital data in conjunction with meteorological data can be effectively used to monitor regional and worldwide climate changes.

Bayr, Klaus J.↗

Neutron radiography and X-ray computed tomography for quantifying weathering and water uptake processes inside porous limestone used as building material

Euville and Savonnières limestones were weathered by acid test and this resulted in the formation of a gypsum crust. In order to characterize the crystallization pattern and the evolution of the pore structure below the crust, a combination of high resolution X-ray computed tomography and SEM–EDS was used. A time lapse sequence of the changing pore structure in both stones was obtained and afterwards quantified by using image analysis. The difference in weathering of both stones by the same process could be explained by the underlying microstructure and texture. Because water and moisture play a crucial role in the weathering processes, water uptake in weathered and non-weathered samples was characterized based on neutron radiography. In this way the water uptake was both visualized and quantified in function of the height of the sample and in function of time. In general, the formation of a gypsum crust on limestone slows down the initial water uptake in the materials. - Highlights: • Time lapse sequence in 3D of changing pore structures inside limestone • A combination of X-ray CT, SEM and neutron radiography was used. • Quantification of water content in function of time, height and weathering • Characterization of weathering processes due to gypsum crystallization.

36 MATERIALS SCIENCE↗

Low Phosphorylated AKT Expression in Laryngeal Cancer: Indications for a Higher Metastatic Risk

Purpose: To validate the association of phosphorylated (p)AKT with lymph node metastasis in an independent, homogeneous cohort of patients with larynx cancer. Methods and Materials: Seventy-eight patients with laryngeal cancer were included. Epidermal growth factor receptor, pAKT, vimentin, E-cadherin, hypoxia, and blood vessels were visualized in biopsy material using immunohistochemistry. Positive tumor areas and spatial relationships between markers were assessed by automated image analysis. In 6 laryngeal cancer cell lines, E-cadherin and vimentin messenger RNA was quantified by real-time polymerase chain reaction and by immunohistochemistry before and after treatment with the pAKT inhibitor MK-2206. Results: A significant correlation was found between low pAKT in the primary tumor and positive lymph node status (P=.0005). Tumors with lymph node metastases had an approximately 10-fold lower median pAKT value compared with tumors without lymph node metastases, albeit with large intertumor variations, validating our previous results. After inhibition of pAKT in laryngeal cancer cells with MK-2206, up-regulation of vimentin and a downregulation of E-cadherin occurred, consistent with epithelial–mesenchymal transition. Conclusion: Low pAKT expression in larynx tumors is associated with lymph node metastases. Further, inhibition of pAKT in laryngeal cancer induces epithelial–mesenchymal transition, predisposing for an increased metastatic risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diffraction data from aerosolized Coliphage PR772 virus particles imaged with the Linac Coherent Light Source

Single Particle Imaging (SPI) with intense coherent X-ray pulses from X-ray free-electron lasers (XFELs) has the potential to produce molecular structures without the need for crystallization or freezing. Here we present a dataset of 285,944 diffraction patterns from aerosolized Coliphage PR772 virus particles injected into the femtosecond X-ray pulses of the Linac Coherent Light Source (LCLS). Additional exposures with background information are also deposited. The diffraction data were collected at the Atomic, Molecular and Optical Science Instrument (AMO) of the LCLS in 4 experimental beam times during a period of four years. The photon energy was either 1.2 or 1.7 keV and the pulse energy was between 2 and 4 mJ in a focal spot of about 1.3 μm x 1.7 μm full width at half maximum (FWHM). The X-ray laser pulses captured the particles in random orientations. The data offer insight into aerosolised virus particles in the gas phase, contain information relevant to improving experimental parameters, and provide a basis for developing algorithms for image analysis and reconstruction.

59 BASIC BIOLOGICAL SCIENCES↗