Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

The first Shuttle scientific payload /OSTA-1/

On Nov. 12, 1981, the Space Shuttle was launched for its second flight (STS-2). It carried with it the first scientific payload designed to perform remote sensing observations of the earth. During the 54 hour flight, scientific instruments from the OSTA-1 (Office of Space and Terrestrial Applications) payload gathered data over the earth's oceans and land masses, and global atmospheric data on concentrations of carbon monoxide in the atmosphere. The flight demonstrated the capability of the Shuttle to serve as an orbiting platform for scientific research. Instruments were successfully developed for spaceflight for a fraction of the costs associated with instruments flown on unmanned satellite missions. Perhaps most importantly, the instruments have been successfully returned to the investigators for the first time in the history of remote sensing from space.

Taranik, J. V.↗

Mu-Spec: A High Performance Compact Spectrometer for Submillimeter Astronomy

We describe the Mu-Spec, an extremely compact high performance spectrometer for the submillimeter and millimeter spectral ranges. We have designed a fully integrated submillimeter spectrometer based on superconducting microstrip technology and fabricated its critical elements. Using low loss transmission lines, we can produce a fully integrated high resolution submillimeter spectrometer on a single four inch Si wafer. A resolution of 500 can readily be achieved with standard fabrication tolerance, higher with phase trimming. All functions of the spectrometer are integrated - light is coupled to the microstrip circuit with a planar antenna, the spectra discrimination is achieved using a synthetic grating, orders are separated using a built-in planar filter, and the light is detected using photon counting Microwave Kinetic Inductance Detectors (MKID). We will discus the design principle of the instrument, describe its technical advantages, and report the progress on the development of the instrument.

Hsieh, Wen-Ting↗

Micro-Spec: A High Performance Compact Spectrometer for Submillimeter Astronomy

We describe the micro-Spec, an extremely compact high performance spectrometer for the submillimeter and millimeter spectral ranges. We have designed a fully integrated submillimeter spectrometer based on superconducting microstrip technology and fabricated its critical elements. Using low loss transmission lines, we can produce a fully integrated high resolution submillimeter spectrometer on a single four inch Si wafer. A resolution of 500 can readily be achieved with standard fabrication tolerance, higher with phase trimming. All functions of the spectrometer are integrated - light is coupled to the micro strip circuit with a planar antenna, the spectra discrimination is achieved using a synthetic grating, orders are separated using a built-in planar filter, and the light is detected using photon counting Microwave Kinetic Inductance Detectors (MKID). We will discus the design principle of the instrument, describe its technical advantages, and report the progress on the development of the instrument.

Hsieh, Wen-Ting↗

Sea surface temperatures from the scanning multichannel microwave radiometer on Nimbus 7

Because of problems with the design and calibration of the scanning multichannel microwave radiometer (SMMR) on Nimbus 7, sea surface temperature (SST) algorithms had to be developed that corrected for instrument effects. Several stages of this development are reported here. The quality of the SST products from the final version is assessed. Thirty-four months of data have been analyzed; the average SST error is about 1.12 C over the whole globe. The error is smaller in the equatorial region and larger in the northern oceans. The main source of error is due to heating of the SMMR instrument. Specific problems in the design of the instrument are discussed. The details of the ST algorithms are given in an appendix.

Milman, A. S.↗

Addendum report to atmospheric science facility pallet-only mode space transportation system payload feasibility study, volume 3, revision A

The feasibility of accomplishing selected atmospheric science mission using a pallet-only mode was studied. Certain unresolved issues were identified. The first issue was that of assuring that the on-board computer facility was adequate to process scientific data, control subsystems such as instrument pointing, provide mission operational program capability, and accomplish display and control. The second issue evolved from an investigation of the availability of existing substitute instruments that could be used instead of the prime instrumentation where the development tests and schedules are incompatible with the realistic budgets and shuttle vehicle schedules. Some effort was expended on identifying candidate substitute instruments, and the performance, cost, and development schedule trade-offs found during that effort were significant enough to warrant a follow-on investigation. This addendum documents the results of that follow-on effort, as it applies to the Atmospheric Sciences Facility.

Source record↗

Development of a versatile laser light scattering instrument

NASA Lewis Research Center is providing and coordinating the technology for placing a compact Laser Light Scattering (LLS) instrument in a microgravity environment. This will be accomplished by defining and assessing user requirements for microgravity experiments, coordinating needed technological developments, and filling technical gaps. This effort is striving to brassboard and evaluate a miniature multi-angle LLS instrument. The progress of the program is reported.

Meyer, William V.↗

Evaluation of submarine strain-gage systems for monitoring coastal sediment migration

Single and multiple strain-gage systems were respectively evaluated as in situ point and areal sensors for monitoring sand-height variations in coastal environments. Static loading tests indicate that gage response pressure is linear for sand heights up to 24 inches. Response pressures are a function of both sand height and aggregate density, with density being influenced by both sediment texture and degree of compaction. Poorer sediment sorting and greater compaction result in higher response pressures. Field tests in a beach foreshore environment indicate that the gage systems are effective qualitative instruments for monitoring long-period migration trends of beach sediments; whereas, short-period responses are not sufficiently reliable. The durability and compactness of the gage systems must be substantially increased for effective field operations. It is recommended that the systems' qualitative potentials be further developed, whereas their development as quantitative instruments be terminated. Further development should emphasize the construction of remote recording systems designed for semipermanent installation.

Shideler, G. L.↗

A Comprehensive Forward Model for Spaceborne Radar Instruments

We present the development and validation of a comprehensive forward model designed to enhance remote sensing capabilities of spaceborne radar instruments. To overcome limitations in existing models, we integrated a Discrete Dipole Approximation (DDA) cloud scattering database into our Radiative Transfer Model (RTM), focusing on microwave frequencies. By simulating the optical properties of non-spherical frozen hydrometeors, the DDA technique effectively reduced discrepancies between simulated and observed values, surpassing traditional Mie tables. The evaluation of DDA lookup tables involved comparisons with a collocated dataset comprising short-term forecasts and satellite microwave data, providing evidence of their superiority. Additionally, we address the challenges of assimilating active radar measurements, which offer vertically resolved insights into clouds and precipitation. We explored the assimilation of spaceborne radar measurements in Numerical Weather Prediction (NWP) models by integrating a forward radar model, along with its adjoint and tangent linear, into the data assimilation system. Evaluation using CloudSat measurements demonstrated promising agreement between simulations and observations, particularly when the input hydrometeor profiles aligned with the measured reflectivity profiles, showcasing the potential of the developed forward radar model. Moreover, we discuss other challenges in radar measurement assimilation within NWP models, including potential observation errors and biases.

Isaac Moradi↗

Piezoelectrically actuated miniature peristaltic pump.

There is a range of NASA experiments, instruments and applications where miniature pumps are needed. To address such needs, a piezoelectrically actuated miniature pump is being developed. This pump employs a novel volume displacing mechanism using flexural traveling waves that acts peristaltically and eliminates the need for valves or physically moving parts. This pump is being developed for planetary instruments and space applications. Finite element model was developed using ANSYS for the purpose of prediction of the resonance frequency of the vibrating mode for the piezo-pump driving stator. The model allows determining simultaneously the mode shapes that are associated with the various resonance frequencies. This capability is essential for designing the pump size and geometry. To predict and optimize the pump efficiency that is determined by the volume of pumping chambers the model was modified to perform harmonic analysis.

Chang, Zensheu↗

Development of contamination requirements for spaceborne optical instrumentation

High performance satellites and critical surfaces aboard advanced long-life spacecraft require effective contamination control measures to maintain performance stability and to ensure data accuracy. Contamination is said to exist and be of concern if a spacecraft or launch vehicle produced material interferes with the intended performance of a surface or sensor. This paper will discuss the development of contamination requirements for spaceborne optical instrumentation. In addition, a comparison of instrument contamination requirements to measured instrument degradation levels for mission activities will be presented. If maintained, these requirements ensure against undesirable instrument degradation due to the contamination environment created by fabrication, launch, mission activities, ambient atmosphere and the instruments themselves.

Hansen, Patricia A.↗

Development and testing of the television instrument for the Mariner Mars 1971 spacecraft

The Mariner Mars 1971 television instrument is described. It emphasizes those aspects that are different from the Mariner Mars 1969 television subsystem. The various modes of operation are described and functional descriptions of the major elements in the system summarized. An electronic description of the circuits that differ from those of Mariner Mars 1969 is also presented along with a brief description of the calibration and test sequences.

Source record↗

Development and design of three monitoring instruments for spacecraft charging

A set of instruments which provide early detection of potentially dangerous geomagnetic substorm conditions and monitor the spacecraft response are discussed. The set consists of a sensor that measures the characteristic energy of collected electrons or ions from + 100 to - 20,000 V, a logarithmic current density sensor that measures local electron flux and a transient events counter that counts the spurious pulses from electrostatic discharges that couple into the spacecraft wiring harness. Design details and performance characteristics of the three instruments are given. Size, weight, and power requirements are minimized.

Sturman, J. C.↗

The Airborne Ocean Color Imager - System description and image processing

The Airborne Ocean Color Imager was developed as an aircraft instrument to simulate the spectral and radiometric characteristics of the next generation of satellite ocean color instrumentation. Data processing programs have been developed as extensions of the Coastal Zone Color Scanner algorithms for atmospheric correction and bio-optical output products. The latter include several bio-optical algorithms for estimating phytoplankton pigment concentration, as well as one for the diffuse attenuation coefficient of the water. Additional programs have been developed to geolocate these products and remap them into a georeferenced data base, using data from the aircraft's inertial navigation system. Examples illustrate the sequential data products generated by the processing system, using data from flightlines near the mouth of the Mississippi River: from raw data to atmospherically corrected data, to bio-optical data, to geolocated data, and, finally, to georeferenced data.

Wrigley, Robert C.↗

Interstellar nomads: The problem of detecting comets

This paper shows that, using only a modest extrapolation of current phased-array radar and massively parallel processor computer technologies, radar transmitter in the outer solar system or in interstellar space could be used to detect comets passing within 1 or 2 AU of the transmitter. It discusses how this potential development could be instrumental to the colonisation of the outer solar system and beyond. This development is germane to contemporary investigations of the population of the Oort cloud as well as to the Search for Extraterrestrial Intelligence (SETI) question.

Jones, Eric M.↗

Oceanographic Research

The PNF-300 Natural Fluorometer is an optical instrument for oceanographic research developed under NASA contract by Biospherical Instruments, Inc. An important innovation for oceanographers, it measures photosynthetic productivity and estimates phytoplankton production less expensively, is non-intrusive and can be used on site - an improved way of estimating ocean productivity. Applications include environmental impact studies, monitoring plankton concentrations in a reservoir, and other research uses.

Source record↗

Flame Detector

Scientific Instruments, Inc. has now developed a second generation, commercially available instrument to detect flames in hazardous environments, typically refineries, chemical plants and offshore drilling platforms. The Model 74000 detector incorporates a sensing circuit that detects UV radiation in a 100 degree conical field of view extending as far as 250 feet from the instrument. It operates in a bandwidth that makes it virtually 'blind' to solar radiation while affording extremely high sensitivity to ultraviolet flame detection. A 'windowing' technique accurately discriminates between background UV radiation and ultraviolet emitted from an actual flame, hence the user is assured of no false alarms. Model 7410CP is a combination controller and annunciator panel designed to monitor and control as many as 24 flame detectors. *Model 74000 is no longer being manufactured.

Source record↗