Search NASA⌕ Search

SEARCH · Search NASA

Results for “LABORATORY SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

The SLAC P2 Marx

A proposed high energy physics accelerator, the International Linear Collider, will require greater than five hundred rf stations. Each station is composed of a klystron driven by a modulator. Recently, the SLAC P2 Marx was designated the baseline modulator for the ILC. This paper describes some key features of this modulator and presents recent experimental results. The P2 Marx is presently being transported to another facility for lifetime testing. Here, we will gain understanding of how the Marx performs into a klystron load and gain experience operating the Marx for longer periods. Long term plans include the possibility of using this rf station for L-band technology demonstration at SLAC. While the Marx was designed with the ILC in mind, the topology can be readily applied to several different applications. We are currently evaluating the use of the topology for ESS, CLIC, and upgrades for systems at Fermi National Accelerator Laboratory. Because of the modular nature of the cell and the robustness of the control system, many different combinations of series and parallel operation are possible along with different load currents and pulse shapes.

43 PARTICLE ACCELERATORS↗

Sustainable Campus with PEV and Microgrid

Market penetration of electric vehicles (EVs) is gaining momentum, as is the move towards increasingly distributed, clean and renewable electricity sources. EV charging shifts a significant portion of transportation energy use onto building electricity meters. Hence, integration strategies for energy-efficiency in buildings and transport sectors are of increasing importance. This paper focuses on a portion of that integration: the analysis of an optimal interaction of EVs with a building-serving transformer, and coupling it to a microgrid that includes PV, a fuel cell and a natural gas micro-turbine. The test-case is the Nanyang Technological University (NTU), Singapore campus. The system under study is the Laboratory of Clean Energy Research (LaCER) Lab that houses the award winning Microgrid Energy Management System (MG-EMS) project. The paper analyses three different case scenarios to estimate the number of EVs that can be supported by the building transformer serving LaCER. An approximation of the actual load data collected for the building into different time intervals is performed for a transformer loss of life (LOL) calculation. The additional EV loads that can be supported by the transformer with and without the microgrid are analyzed. The numbers of possible EVs that can be charged at any given time under the three scenarios are also determined. The possibility of using EV fleet at NTU campus to achieve demand response capability and intermittent PV output leveling through vehicle to grid (V2G) technology and building energy management systems is also explored.

Singh, Reshma↗

Common Cause Failure Evaluation of High Safety Significant Safety-related Digital Instrumentation and Control Systems using IRADIC Technology

Digital instrumentation and control (DI&C) systems in nuclear power plants (NPPs) have many advantages over analog systems but also pose different engineering and technical challenges, such as potential threats due to common cause failures (CCFs). This paper proposes an integrated risk assessment technology for DI&C systems (IRADIC) developed by Idaho National Laboratory for dealing with potential software CCFs in DI&C systems of NPPs. The methodology development of the IRADIC technology on the quantitative evaluation of software CCFs in high safety-significant safety-related DI&C systems in NPPs is illustrated in this paper. In IRADIC, qualitative hazard analysis and quantitative reliability and consequence analysis are successively implemented to obtain quantitative risk information, compare with respective risk evaluation acceptance criteria, and provide suggestions for risk reduction and design optimization. A comprehensive case study was also performed and documented in this paper. Results show that the IRADIC technology can effectively identify potential digital-based CCFs, estimate their failure probabilities, and evaluate their impacts to system and plant safety.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

7 Innovations in high-rate composite manufacturing: integrating additive manufacturing with compression molding process

Advanced composites play a pivotal role in modern engineering, offering exceptional strength-to-weight ratios and tailored properties, essential for various industries. High-rate composite manufacturing techniques have rapid production capabilities, which are essential for meeting the demands of industries requiring cost-saving, efficiency, and quick turnaround times. This chapter explores the Additive Manufacturing- Compression Molding (AM-CM) system developed by Oak Ridge National Laboratory (ORNL) for advanced composites manufacturing. The AM-CM system integrates additive manufacturing with compression molding, facilitating the production of polymer composite parts with superior mechanical properties and meticulously controlled microstructures. This innovative system not only ensures precise material deposition but also operates as a fast composite manufacturing process, enhancing productivity and performance, which are needed attributes across industrial applications. Through comprehensive mechanical testing and microstructural analysis, AM-CM promotes remarkable fiber alignment and reduced porosity in composite parts compared to alternative thermoplastic high-rate composite manufacturing methods. Furthermore, AM-CM enables overmolding reinforcement using continuous carbon fiber and supports selective reinforcement through customizable toolpaths. It also facilitates the production of hybrid materials to achieve tailored mechanical properties. Future advancements in AM-CM technology aim to enhance process efficiency, broaden material versatility, and improve part performance. This involves exploring novel materials, advancing process monitoring, implementing automation technologies, and integrating artificial intelligence (AI) and machine learning (ML) for predictive modeling and real-time optimization in composite manufacturing. These developments will establish the AM-CM system as a transformative technology in composite manufacturing, driving innovation across industries.

Hassen, Ahmed [ORNL] (ORCID:0000000328521222)↗

Development and Characterization of a High-Energy Neutron Time-of-Flight Imaging System

We present that Los Alamos National Laboratory has developed a prototype of a high-energy neutron time-of-flight imaging system for the non-destructive evaluation of dense, massive, and/or high atomic number objects. High-energy neutrons provide the penetrating power, and thus the high dynamic range necessary to image internal features and defects of such objects. The addition of the time gating capability allows for scatter rejection when paired with a pulsed monoenergetic beam, or neutron energy selection when paired with a pulsed broad-spectrum neutron source. The Time Gating to Reject Scatter and Select Energy (TiGReSSE) system was tested at the Los Alamos Neutron Science Center’s (LANSCE) Weapons Nuclear Research (WNR) facility, a spallation neutron source, to provide proof of concept measurements and to characterize the instrument response. This paper will show results of several objects imaged during this run cycle. In addition, results from system performance metrics such as the Modulation Transfer Function and the Detective Quantum Efficiency measured as a function of neutron energy, characterize the current system performance and inform the next generation of neutron imaging instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OPERATIONAL EXPERIENCE OF THE UPGRADED CRYOGENIC SYSTEMS AT THE NSCL

The National Superconducting Cyclotron Laboratory (NSCL) is a NSF-supported facility, with additional support from Michigan State University (MSU) for conducting research in nuclear and accelerator science. The facility consists of two superconducting cyclotrons and over fifty individual cryostats, each containing several superconducting magnets that are used in the beam transport system. Beginning in 1999 a major facility upgrade was started. New, larger magnets were added, increasing the total 4.5 K loads, necessitating an increase of the cryogenic capacity. A helium plant (nominal 1750-Watt at 4.5 K) was acquired from the United States Bureau of Mines where it had been operating as a pure liquefier since the early 1980's. It was refurbished for the NSCL with extensive support from the cryogenics group at Thomas Jefferson National Laboratory. The new cryogenic system came online early in 2001. The cold-mass is relatively high in relation to the installed capacity, presenting challenges during cool downs. Reliability over the last five years has been greater than 99%. An overview of the last seven years of operations of our cryogenic systems is presented that includes normal operations, testing of new equipment, noteworthy breakdowns, routine maintenance, and system reliability.

43 PARTICLE ACCELERATORS↗

Control systems and data management for high-power laser facilities

The next generation of high-power lasers enables repetition of experiments at orders of magnitude higher frequency than what was possible using the prior generation. Facilities requiring human intervention between laser repetitions need to adapt in order to keep pace with the new laser technology. A distributed networked control system can enable laboratory-wide automation and feedback control loops. These higher-repetition-rate experiments will create enormous quantities of data. A consistent approach to managing data can increase data accessibility, reduce repetitive data-software development and mitigate poorly organized metadata. An opportunity arises to share knowledge of improvements to control and data infrastructure currently being undertaken. We compare platforms and approaches to state-of-the-art control systems and data management at high-power laser facilities, and we illustrate these topics with case studies from our community

47 OTHER INSTRUMENTATION↗

Mastering HPC Runtime Prediction: From Observing Patterns to a Methodological Approach

The continual expansion of high-performance computing (HPC) brings with it an increasing need for efficiency. Heavy investment in energy, hardware, and software infrastructure to support peta- and exascale computing requires the optimization of existing systems and, wherever possible, the discernment and adoption of best-practices towards these goals. Such is the case for runtime prediction. When a job is submitted to an HPC system, an estimate of its runtime is provided by the user in the form of "requested wallclock". Error in this user-provided estimate can lead to jobs being prematurely killed by the scheduler, increased wait time on the queue, and decreased system utilization. More than fifteen years of research has been directed at mitigating these effects by using data-driven runtime predictions. Codified here is a set of commonalities and insights emerging from this body of work, which we present as recommendations and best practices. These practices are combined into a methodological approach described and evaluated on an 11-million-job dataset from the National Renewable Energy Laboratory's petascale HPC system, Eagle. This dataset and the accompanying codebase have been released to the public domain for the benefit of the wider HPC research community.

high performance computing↗

Mastering HPC Runtime Prediction: From Observing Patterns to a Methodological Approach: Preprint

The continual expansion of high-performance computing (HPC) brings with it an increasing need for efficiency. Heavy investment in energy, hardware, and software infrastructure to support peta- and exascale computing requires the optimization of existing systems and, wherever possible, the discernment and adoption of best-practices towards these goals. Such is the case for runtime prediction. When a job is submitted to an HPC system, an estimate of its runtime is provided by the user in the form of "requested wallclock''. Error in this user-provided estimate can lead to jobs being prematurely killed by the scheduler, increased wait time on the queue, and decreased system utilization. More than fifteen years of research has been directed at mitigating these effects by using data-driven runtime predictions. Codified here is a set of commonalities and insights emerging from this body of work, which we present as recommendations and best practices. These practices are combined into a methodological approach described and evaluated on an 11-million-job dataset from the National Renewable Energy Laboratory's petascale HPC system, Eagle. This dataset and the accompanying codebase have been released to the public domain for the benefit of the wider HPC research community.

high performance computing↗

In-situ angle-resolved photoemission spectroscopy of copper-oxide thin films synthesized by molecular beam epitaxy

We present that angle-resolved photoemission spectroscopy (ARPES) is the key momentum-resolved technique for direct probing of the electronic structure of a material. However, since it is highly surface-sensitive, it has been applied to a relatively small set of complex oxides that can be easily cleaved in ultra-high vacuum. Here we describe a new multi-module system at Brookhaven National Laboratory (BNL) in which an oxide molecular beam epitaxy (OMBE) is interconnected with an ARPES and a spectroscopic-imaging scanning tunneling microscopy (SI-STM) module. This new capability largely expands the range of complex-oxide materials and artificial heterostructures accessible to these two most powerful and complementary techniques for studies of electronic structure of materials. Lastly, we also present the first experimental results obtained using this system — the ARPES studies of electronic band structure of a La 2-x Sr x CuO 4 (LSCO) thin film grown by OMBE.

36 MATERIALS SCIENCE↗

Method and System for Accessing PV Resource Data from the NSRDB

This study developed a capability to provide spectrally resolved solar resource data from the National Solar Radiation Data Base (NSRDB) effectively providing 20 years of half-hourly data for all of the US at a 4kmx4km spatial resolution. This data is now available freely to users directly through a GIS based web interface (https://nsrdb.nrel.gov) as well as through an Application Programming Interface. Users of this data can conduct more accurate pre-feasibility studies and assess multiple PV technologies. It is expected that widely used models such as PVSyst, National Renewable Energy Laboratory’s (NREL’s) System Advisor Model (SAM) and First Solar designed PlantPredict will develop the capabilities to use this spectral data.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Secure Control Systems for the Energy Sector

Schweitzer Engineering Laboratories (SEL) will conduct the Hallmark Project to address the need to reduce the risk of energy disruptions because of cyber incidents on control systems. The goals is to develop solutions that can be both applied to existing control systems and designed into new control systems to add the security measures needed to mitigate energy network vulnerabilities. The scope of the Hallmark Project contains four primary elements: 1. Technology transfer of the Secure Supervisory Control and Data Acquisition (SCADA) Communications Protocol (SSCP) from Pacific Northwest National Laboratories (PNNL) to Schweitzer Engineering Laboratories (SEL). The project shall use this technology to develop a Federal Information Processing Standard (FIPS) 140-2 compliant original equipment manufacturer (OEM) module to be called a Cryptographic Daughter Card (CDC) with the ability to directly connect to any PC enabling that computer to securely communicate across serial to field devices. Validate the OEM capabilities with another vendor. 2. Development of a Link Authenticator Module (LAM) using the FIPS 140-2 validated Secure SCADA Communications Protocol (SSCP) CDC module with a central management software kit. 3. Validation of the CDC and Link Authenticator modules via laboratory and field tests. 4. Creation of documents that record the impact of the Link Authenticator to the operators of control systems and on the control system itself. The information in the documents can assist others with technology deployment and maintenance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel $In-Situ$ Radiation Damage Diagnostic System for Undulators

Radiation damage has been a known problem at many synchrotron radiations and free-electron lasers facilities, especially those that use hybrid or pure permanent magnet undulators to produce high brightness light. Field strength loss due to demagnetization makes it necessary to remove the insertion device from the tunnel for inspection and repair, which brings several inconveniences. We aimed to develop an in situ radiation damage detection system for undulators capable of diagnosing relative field changes of 10 -4 (100 ppm) or smaller. The system measures the flux change in a flexible printed circuit board coil attached to the undulator magnet array by periodically measuring the integral flux change during the opening and closing of the undulator gap. If the magnet block damage occurs, the signal from the coil will decrease proportionally to the damage. First tests performed on variable gap hybrid undulators for the Linac Coherent Light Source II (LCLS-II) at SLAC National Accelerator Laboratory showed that the system is capable of measuring flux changes with a relative precision of approximately 0.7 × 10 -4 over several days. Relative field changes smaller than 10 -4 were detected in short-term measurements. Here, the novel system that we propose here opens the possibility of detecting radiation damage in undulators during operation.

47 OTHER INSTRUMENTATION↗

Salt mass determination by 22 Na-based radioactive tracer dilution of a highly radioactive molten salt system for pyroprocessing spent oxide nuclear fuels

To demonstrate the feasibility of the 22 Na-based radioactive tracer dilution (RTD) for determining the total salt mass in a 60-kg oxide reduction (OR) system at Idaho National Laboratory (INL) for pyroprocessing spent oxide nuclear fuels, a LiCl- 22 NaCl tracer salt was prepared and spiked to the OR vessel, and salt samples were analyzed by gamma spectroscopy. Due to the high radioactivity (around 10 mCi/g) of the OR salt, mainly from 137 Cs, traditional gamma spectroscopy methods, which typically involve diluted salt samples, was not effective for analyzing the RTD samples. Since the 22 Na tracer radioactivity was very low, undiluted samples were necessary to detect the small amount of 22 Na tracer. Here, despite the high gamma radioactivity of the OR salt, increasing the detector-sample distance from 20 cm to 40 cm during gamma spectroscopy allowed the detection of radioactivity as low as 0.12 µCi/g 22 Na. The preparation of the 22 NaCl-LiCl tracer salt suitable for spiking into the OR salt was successful, and the mass determined by RTD was consistent with that estimated by salt level measurement. Therefore, the 22 Na-based RTD technique for total mass determination of the 60-kg molten salt system for OR is feasible, though more development work, particularly in the improving the uncertainty, is needed .

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurements with Pinhole and Coded Aperture Gamma-Ray Imaging Systems

From a safeguards perspective, gamma-ray imaging has the potential to reduce manpower and cost for effectively locating and monitoring special nuclear material. The purpose of this project was to investigate the performance of pinhole and coded aperture gamma-ray imaging systems at Oak Ridge National Laboratory (ORNL). With the aid of the European Commission Joint Research Centre (JRC), radiometric data will be combined with scans from a three-dimensional design information verification (3D-DIV) system. Measurements were performed at the ORNL Safeguards Laboratory using sources that model holdup in radiological facilities. They showed that for situations with moderate amounts of solid or dense U sources, the coded aperture was able to predict source location and geometry within ~7% of actual values while the pinhole gave a broad representation of source distributions

Raffo-Caiado, Ana Claudia↗

Dynamometer Testing of a NW2200 Drivetrain (CRADA Final Report)

Northern Power Systems specializes in direct drive wind turbine designs. CRADA CRD-10-394 involved testing the NW2200 wind turbine power train. Power train testing is important because it allows validation of the generator design and some control algorithms prior to installation on a tower, where this data would be more difficult and time consuming to collect. In an effort to keep the commercialproduct schedule on time, Northern Power requested testing support from the National Renewable Energy Laboratory for this testing. The test program was performed using NREL's 2.5 MW dynamometer test bed at the National Wind Technology Center near Boulder, CO.

17 WIND ENERGY↗

Safe Active Scanning for Energy Delivery Systems Final Report

The Department of Energy’s Cybersecurity for Energy Delivery Systems Program has funded Safe(r) Active Scanning for Energy Delivery Systems, led by Lawrence Livermore National Laboratory, to investigate and analyze the impacts of active scanning in the operational environment of energy delivery systems. In collaboration with Pacific Northwest National Laboratory and Idaho National Laboratory, active scans across three testbeds including 38 devices were performed. This report gives a summary of the initial literature survey performed on the SASEDS project as well as industry partner interview summaries and main findings from Phase 1 of the project. Additionally, the report goes into the details of scanning techniques, methodologies for testing, testbed descriptions, and scanning results, with appendices to elaborate on the specific scans that were performed. As a result of testing, a single device out of 38 exhibited problems when actively scanned, and a reboot was required to fix it. This single failure indicates that active scanning is not likely to have a detrimental effect on the safety and resilience of energy delivery systems. We provide a path forward for future research that could enable wide adoption of active scanning and lead utilities to incorporate active scanning as part of their default network security plans to discover and rectify rogue devices, adversaries, and services that may be on the network. This increased network visibility will allow operational technology cybersecurity practitioners to improve their situational awareness of networks and their vulnerabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗