Search NASA⌕ Search

SEARCH · Search NASA

Results for “Leak Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Use of Micro-Gravity Sensors for External Fluid Level Monitoring in Waste and Nuclear Related Applications - 20315

There are a number of applications in nuclear energy and hazardous waste disposal that require monitoring of fluids under extreme environments, including high levels of temperature, pressure, toxicity and radioactivity. Many of these applications will benefit from a monitoring technique that is external and non-invasive. Currently the sensors used are invasive, must reside inside the pressurized vessels and must penetrate the vessel walls, which can create a weakness in the vessel. Additionally, instruments that are used inside such containers must be exceptionally hardened to the environment. Information Systems Laboratories (ISL) has developed an external mass (gravimetric) measuring technique for monitoring nuclear coolant in Small Modular Reactors (SMRs), which will also work for measuring fluid levels in waste tanks, that avoids the problems inherent in invasive sensors. It utilizes a COTS gravitational sensor of unprecedented accuracy, leveraged via proper sensor placement geometry, to detect fluid changes of small amplitude from an outside position, obviating the need to penetrate the vessel. The technique is called Gravisense{sup TM}. ISL has proven via simulation and experiment that this concept can be usefully applied to monitoring fluid levels in both nuclear reactors and large waste tanks. Numerical simulation algorithms were developed to calculate the gravity effect of small changes in water level, which were verified by experiments at the NIST Physical Simulator facility at the Oregon State University. The measured ultralow noise levels of the superconducting gravimeter type which utilizes a Niobium sphere suspended in a magnetic field to attain its phenomenal accuracy, demonstrated that fluid levels in SMRs can be measured at least to within 3 cm. Furthermore, the method can distinguish between a contained leak (from reactor to containment vessel) from an external leak (from reactor to outside of containment). Additionally, simulations of waste canisters that hold spent fuel rods show that the fluid level measuring accuracy can potentially do better than 1 cm accuracy by measuring from below the vessel, and judicious placement of sensors on top of large waste tanks can potentially achieve a very impressive 2 mm measurement accuracy. These encouraging results prove that the Gravisense{sup TM} technique for fluid determination can be very useful in nuclear energy generation, testing, and research, as well as in waste monitoring situations that are difficult to monitor via traditional sensing technology. We believe that the next step should be to test the technique on canisters of the type that are currently storing waste in various DOE locations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and fabrication of a 30 T superconducting solenoid using overpressure processed Bi2212 round wire

High field superconducting magnets are used in particle colliders, fusion energy devices, and spectrometers for medical imaging and advanced materials research. Magnets capable of generating fields of 20-30 T are needed by future accelerator facilities. A 20-30 T magnet will require the use of high-temperature superconductors (HTS) and therefore the challenges of high field HTS magnet development need to be addressed. Superconducting Bi 2 Sr 2 CaCu 2 O x (Bi2212) conductors fabricated by the oxide-powder-in-tube (OPIT) technique have demonstrated the capability to carry large critical current density of 10 5 A/cm 2 at 4.2 K and in magnetic fields up to 45 T. Available in round wire multi-filamentary form, Bi2212 may allow fabrication of 20-50 T superconducting magnets. Until recently the performance of Bi2212 has been limited by challenges in realizing high current densities (J c ) in long lengths. This problem now is solved by the National High Magnetic Field Lab using an overpressure (OP) processing technique, which uses external pressure to process the conductor. OP processing also helps remove the ceramic leakage that results when Bi-2212 liquid leaks out from the sheath material and reacts with insulation, coil forms, and flanges. Significant advances have also been achieved in developing novel insulation materials (TiO 2 coating) and Ag-Al sheath materials that have higher mechanical strengths than Ag-0.2wt.% Mg, developing heat treatment approaches to broadening the maximum process temperature window, and developing high-strength, mechanical reinforced Bi-2212 cables. In the Phase I work, we leveraged these new opportunities to prototype overpressure processed solenoids and test them in background fields of up to 14 T. Additionally a design of a fully superconducting 30 T solenoid was produced. This work in conjunction with the future path outlined in the Phase II proposal would provide a major step toward qualifying Bi2212 technology for use in high-field accelerator magnets. Additionally, the performance parameters match key requirements of a final muon beam cooling solenoid. This technology will also be of interest to high-field NMR manufacturers.

43 PARTICLE ACCELERATORS↗

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensor systems were tested to measure the key parameters, such as hoop strain, pipe pressure, surrounding soil temperature, and acoustic vibrations. The underground product pipeline’s outer diameter is 30 inches, the wall thickness is 1.28 inches, and 3 feet deep from the surface. The fiber deployment strategies and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety. These findings from pilot-scale testing offer valuable insights into advancing pipeline monitoring technologies and improving the reliability of underground pipeline systems.

fiber optic sensors↗

NASA's International Space Station: A Testbed for Planetary Protection Protocol Development

Wherever humans go, they inevitably carry along the critters that live in and on them. Conventional wisdom has long held that it is unlikely those critters could survive the space environment, but in 2007 some microscopic aquatic animals called Tardigrades survived exposure to space and in 2008 Cyanobacteria lived for 548 days outside the ISS. Unlike the Mars rovers that were cleaned once and sent on their way, crew members will provide a constantly regenerating contaminant source. Are we prepared to certify that we can meet forward contamination protocols as we search for life at new destinations? What about the organisms we might reasonably expect a crewed spacecraft to leak or vent? Do we even know what they are? How long might our tiny hitch-hikers survive in close proximity to a warm spacecraft that periodically leaks/vents water or oxygen and how might they mutate with long-duration exposure? How will these contaminants migrate from their source in conditions encountered in space or on other planetary surfaces? This project aims to answer some of these questions by bringing together key stakeholder communities to develop a human forward contamination test, analysis, and integration plan. A system engineering approach to identify the experiments, analysis, and modeling needed to develop the contamination control protocols required will be used as a roadmap to integrate the many different parts of this problem - from launch to landing, living, and working on another planetary surface.

Bell, M. S.↗

Nasa's International Space Station: A Testbed for Planetary Protection Protocol Development

Wherever humans go, they inevitably carry along the critters that live in and on them. Conventional wisdom has long held that it is unlikely those critters could survive the space environment, but in 2007 some microscopic aquatic animals called Tardigrades survived exposure to space and in 2008 Cyanobacteria lived for 548 days outside the ISS. Unlike the Mars rovers that were cleaned once and sent on their way, crew members will provide a constantly regenerating contaminant source. Are we prepared to certify that we can meet forward contamination protocols as we search for life at new destinations? What about the organisms we might reasonably expect a crewed spacecraft to leak or vent? Do we even know what they are? How long might our tiny hitch-hikers survive in close proximity to a warm spacecraft that periodically leaks/vents water or oxygen and how might they mutate with long-duration exposure? How will these contaminants migrate from their source in conditions encountered in space or on other planetary surfaces? This project aims to answer some of these questions by bringing together key stakeholder communities to develop a human forward contamination test, analysis, and integration plan. A system engineering approach to identify the experiments, analysis, and modeling needed to develop the contamination control protocols required will be used as a roadmap to integrate the many different parts of this problem - from launch to landing, living, and working on another planetary surface.

Bell, M. S.↗

Thermal shock resistance of multilayer silicon carbide receiver tubes for 800°C molten salt concentrating solar power application

CSP power tower receiver systems during rapid transient weather periods can be vulnerable to thermal shock conditions from rain that which can facilitate the onset of leaks and failures that can have catastrophic consequences. Silicon carbide (SiC) materials have attractive receiver application characteristics for being light weight, having high-strength and excellent thermal shock resistance performance which make them a particularly good fit for receiver absorber materials in CSP. In this investigation, the performance characteristics of Ceramic Tubular Products (CTP) SiC ceramic matrix composite (CMC), multilayered tubes were explored with respect to thermal shock performance for solar receiver applications in next generation CSP plants. Here, thermal shock testing was performed at the Sandia National Laboratories (SNL) Solar Furnace facility using a dynamic stage and thermal shock tube test setup. The tubes tested under incident solar heat flux of 100 W/cm2 were heated with inner tube temperatures reaching approximately 800 °C, with outer temperatures exceeding or just reaching 1000 El for the multilayer and monolithic SiC tubes respectively. The tubes were then quenched with simulated rain. The tubes were then cooled and subjected to hoop stress analysis using an Instron device to assess their subsequent mechanical strength. Furthermore, the on-sun study experimental results indicate an average of 24.2% and 97% higher hoop strength for the CMC tubes than those composed of monolithic SiC and aluminum oxide (A1203) respectively.

14 SOLAR ENERGY↗

The HDUV Survey: Six Lyman Continuum Emitter Candidates at z ∼ 2 Revealed by HST UV Imaging

We present six galaxies at z∼2 that show evidence of Lyman continuum (LyC) emission based on the newly acquired UV imaging of the Hubble Deep UV legacy survey (HDUV) conducted with the WFC3/UVIS camera on the Hubble Space Telescope (HST). At the redshift of these sources, the HDUV F275W images partially probe the ionizing continuum. By exploiting the HST multiwavelength data available in the HDUV/GOODS fields, models of the UV spectral energy distributions, and detailed Monte Carlo simulations of the intergalactic medium absorption, we estimate the absolute ionizing photon escape fractions of these galaxies to be very high—typically >60% (>13% for all sources at 90% likelihood). Our findings are in broad agreement with previous studies that found only a small fraction of galaxies with high escape fraction. These six galaxies compose the largest sample yet of LyC leaking candidates at z∼2 whose inferred LyC flux has been observed at HST resolution. While three of our six candidates show evidence of hosting an active galactic nucleus, two of these are heavily obscured and their LyC emission appears to originate from star-forming regions rather than the central nucleus. Extensive multiwavelength data in the GOODS fields, especially the near-IR grism spectra from the 3D-HST survey, enable us to study the candidates in detail and tentatively test some recently proposed indirect methods to probe LyC leakage. High-resolution spectroscopic follow-up of our candidates will help constrain such indirect methods, which are our only hope of studying f {sub esc} at z∼5−9 in the JWST era.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantifying Pilot Contribution to Flight Safety during Hydraulic Systems Failure

Accident statistics cite the flight crew as a causal factor in over 60% of large transport aircraft fatal accidents. Yet, a well-trained and well-qualified pilot is acknowledged as the critical center point of aircraft systems safety and an integral safety component of the entire commercial aviation system. The latter statement, while generally accepted, cannot be verified because little or no quantitative data exists on how and how many accidents/incidents are averted by crew actions. A joint NASA/FAA high-fidelity motion-base human-in-the-loop test was conducted using a Level D certified Boeing 737-800 simulator to evaluate the pilot's contribution to safety-of-flight during routine air carrier flight operations and in response to aircraft system failures. To quantify the human's contribution, crew complement (two-crew, reduced crew, single pilot) was used as the independent variable in a between-subjects design. This paper details the crew's actions, including decision-making, and responses while dealing with a hydraulic systems leak - one of 6 total non-normal events that were simulated in this experiment.

Kramer, Lynda J.↗

DESIGN AND DEVELOPMENT OF A HELIUM PURIFIER

Director: Sebastian Bawab. The helium purification system at Jefferson Lab is approaching the end of its design life. Its capacity no longer meets the facility's capacity requirements and consequently, a new system is needed. Several improvements were incorporated into the new purifier design to include extended cycle time, minimum space usage, and convenient placement of components from both safety and maintenance aspects. The purifier design has been completed and the resulting design documentation has been signed and submitted to the Jefferson Lab cryogenic fabrication group. In general, helium purification systems use both a molsieve bed and a carbon bed for purification process. Their function is to remove the contaminants, such as air (moisture, nitrogen, and oxygen) from the helium that enter the system process helium during operations. For continuous operation, usually two sets of purifiers are required, one on-line while the other is being regenerated. Each purification system also contains a nitrogen boiler and a heat exchanger to maintain the temperature of the carbon bed at 80 K (Kelvin) and to minimize liquid nitrogen (LN2) use. The helium purification system at Spallation Neutron Source (SNS) in Oak Ridge, TN, also designed by Jefferson Lab, served as a model for the new system at Jefferson Lab due to similar requirements. However, space restrictions at Jefferson Lab necessitated design modification and re-examination of the beds' capacity. When both the carbon and molsieve beds were the same size (for economical reasons), the life of the molsieve bed was calculated to be longer than the life of the carbon bed for the given contamination level. The design was centered on the limited space and also to make the valves and components easily accessible for the purifier operation. To reduce heat leak from the surroundings and to maintain the carbon bed temperatures at 80 K and to minimize the LN2 usage, a heat exchanger, nitrogen boiler, piping, and miscellaneous items were encased in a vacuum shell. To allow for the flexibility requirements of the piping for the various operating processes, the piping is designed with additional bends and/or length of piping or flex hoses as required. In addition flex hoses were also used to simplify the fabrication process. The beds were designed, fabricated, tested, and inspected to conform to the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section VIII, Rules for Construction of Pressure Vessels. The piping system requirements for design, fabrication, testing and inspection were also made to conform to the ASME Code B31.3, Process Piping. All other design choices were based on sound engineering practices.

Wright, Mathew↗

Sodium Spray Fire Simulations using CONTAIN-LMR

License applications for sodium fast reactors will include sodium fire analysis and subsequent mitigation strategies. Sodium leaks or ruptures from piping and support systems can lead to significant fires due to the reactive nature of sodium with air and water. Understanding the behavior of sodium fires is crucial for modeling and predicting accidents in sodium fast reactors. This paper describes the initial results of a control volume code, CONTAIN-LMR (CLMR), modeling effort for a sodium spray fire experiment conducted at Sandia National Laboratories (SNL) in Albuquerque, New Mexico in 2010. Additional sodium spray and pool fire tests were conducted at SNL in 2009 and 2010 and will be compared to CLMR results in future papers. The purpose of this analysis was extract information from the evolution of the SNL tests to better understand how to use CLMR in future sodium fire analysis. Thus the following CLMR simulations were not completely the result of blind benchmarking study. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AGR-1 Irradiation Test Final As-Run Report, Rev. 3

This document presents the as-run analysis of the AGR-1 irradiation experiment. AGR-1 is the first of eight planned irradiations for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. Funding for this program is provided by the US Department of Energy (DOE) as part of the Next-Generation Nuclear Plant (NGNP) project. The objectives of the AGR-1 experiment are: 1. To gain experience with multi-capsule test train design, fabrication, and operation with the intent to reduce the probability of capsule or test train failure in subsequent irradiation tests. 2. To irradiate fuel produced in conjunction with the AGR fuel process development effort. 3. To provide data that will support the development of an understanding of the relationship between fuel fabrication processes, fuel product properties, and irradiation performance. In order to achieve the test objectives, the AGR-1 experiment was irradiated in the B-10 position of the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) for a total duration of 620 effective full power days of irradiation. Irradiation began on December 24, 2006 and ended on November 6, 2009 spanning 13 ATR cycles and approximately three calendar years. The test contained six independently controlled and monitored capsules. Each capsule contained 12 compacts of a single type, or variant, of the AGR coated fuel. No fuel particles failed during the AGR-1 irradiation. Final burnup values on a per compact basis ranged from 11.5 to 19.6 %FIMA, while fast fluence values ranged from 2.21 to 4.39 x 10 25 n/m 2 (E >0.18 MeV). We’ll say something here about temperatures once thermal recalc is done. Thermocouples performed well, failing at a lower rate than expected. At the end of the irradiation, nine of the originally-planned 19 TCs were considered functional. Fission product release-to-birth (R/B) ratios were quite low. In most capsules, R/B values at the end of the irradiation were at or below 10 -7 with only one capsule significantly exceeding this value. A maximum R/B of around 2 x 10 -7 was reached at the end of the irradiation in Capsule 5. Several shakedown issues were encountered and resolved during the first three cycles. These include the repair of minor gas line leaks; repair of faulty gas line valves; the need to position moisture monitors in regions of low radiation fields for proper functioning; the enforcement of proper on-line data storage and backup, the need to monitor thermocouple performance, correcting for detector spectral gain shift, and a change in the mass flow rate range of the neon flow controllers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hanford Double Shell Waste Tank Corrosion Studies (Final Report FY2019)

During fiscal year (FY) 2019, the Savannah River National Laboratory (SRNL) focused on four primary tasks for Hanford Double Shell Tanks (DSTs) corrosion studies. The first task, New Limits, was a continuation from the electrochemical work started in FY16, to expand electrochemical testing to elevated temperatures and elevated hydroxide concentrations and evaluate how these factors will influence pitting corrosion. Using the pitting factor (PF) equation, these new conditions were validated to provide a conservative estimate for the susceptibility of pitting corrosion on legacy carbon steel. The second task, Secondary Liner Corrosion, focused on Vapor Space Corrosion (VSC) and immersion testing studies using two commercially available vapor corrosion inhibitors (VCIs). For this FY, the VCI strategy was applied mid-experiment to determine performance on weathered coupons. The third task, Long-Term Open Circuit Potential (OCP) Drift, was performed using simplified simulated chemistries to evaluate change in pitting corrosion risk due to evolution of corrosion potential for mill-scale and freshly polished 600-grit surfaces. Finally, the fourth task, Microbiologically-Influenced Corrosion (MIC) studies, was focused on the study of leak detection pit (LDP) water sent from the Hanford tank farm for determination of bacteria that can be conducive to corrosion using commercially available kits: BART TM and MICkit® 5. In addition, this FY, a secondary task was added which was a continuation of the study of the Quartz-enhanced Photoacoustic Spectroscopy (QEPAS) system. Work was started but was ultimately not pursued. A summary of each task performed is presented below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Double ChemFET for the In-Line Monitoring of Silver Dosing in Potable Water Systems

With NASA Advanced Exploration Systems (AES) Life Support Systems (LSS)baselining ionic silver (Ag+) as the biocide of choice, development in silver monitoring technologies becomes necessary to monitor and control Ag+ release. Ion-selective field effect transistors (ISFETs) and chemically-sensitive field effect transistors (ChemFETs) are capable of selective detection of Ag+ with reversible and low detection limit responses. However, one major hurdle to ChemFET technologies is the requirement of a reference electrode, which can leak its fill solution into the potable water system and is prone to drift requiring frequent calibration. To circumvent this issue, a double chemically-sensitive field effect transistor (dChemFET) is proposed. The dChemFET uses a second ChemFET to selectively monitor the counter ion and serves in place of the reference electrode. This work reports on the development of the dChemFET, starting with the development of the Ag+ andNO3- ion selective membranes (ISMs) to be used in the ChemFETs. The Ag+ ISM was tested in 50-105 ppb Ag+ and showed linear, sub-Nernstian response. The NO3- ISM was tested in50-500 ppb silver ion equivalents of nitrate ion (Ag+ equiv. of NO3-) and shows linear, sub-Nernstian response as well . However, the Ag+ and NO3- ISMs face significant challenges in terms of drift that obstruct its application for long-term monitoring, but it can serve as a starting point for demonstrating the dChemFET proof of concept.

John Abdou↗

A Really Good Hammer: Quantification of Mass Transfer Using Perfluorocarbon Tracers (475th Brookhaven Lecture)

Brookhaven Lab’s perfluorocarbon tracer (PFT) technology can be viewed as a hammer looking for nails. But, according to Tom Watson, leader of the Lab’s Tracer Technology Group in the Environmental Research and Technology Division (ERTD), “It’s a really good hammer!” The colorless, odorless and safe gases have a number of research uses, from modeling how airborne contaminants might move through urban canyons to help first responders plan their response to potential terrorist attacks and accidents to locating leaks in underground gas pipes. Their extremely low background level — detectable at one part per quadrillion — allows their transport to be easily tracked. Lab researchers used PFTs during the 2005 Urban Dispersion Program field studies in New York City, gathering data to help improve models of how a gas or chemical release might move around Manhattan’s tall buildings and canyons. Closer to home, scientists also used PFTs to make ventilation measurements in Bldg. 400 on the Lab site to provide data to test air flow models used in determining the effects of passive and active air exchange on the levels of indoor and outdoor air pollution, and to determine the effects of an accidental or intentional release of hazardous substances in or around buildings.

54 ENVIRONMENTAL SCIENCES↗

Electrical design analysis and breakdown voltage test aspects of indigenously developed electrical breaks at Cryo temperatures

Electrical insulation breaks are very critical component of large-scale fusion devices employing superconducting magnets and are used to insulate electrically the coil and the cryogenic supply line (kept at ground potential). The electrical insulation of breaks consists of the composites insulations, G-10 GFRP (Glass fiber reinforced plastic), cryogenic compatible epoxy and S-glass boron free fiber in air and helium environment under vacuum. To optimize the design parameters, the detailed electrical analysis have been carried out using the electrostatic solid axi-symmetric model by COMSOL 4.1 multiphysics software for electrodes separation, electrical field strength as well as flashover phenomenon between two electrodes with composite insulator material have been analyzed at different surfaces and contours along with by varying gaps between SS electrodes. We have carried out the high voltage breakdown test (0-35) kV, insulation resistance measurement at 0-5 kV test voltage in Paschen condition of (10{sup 3} -10{sup -5}) mbar in helium gas and air environment at 300 K and 77 K experimentally on in-house developed insulation breaks. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reliable Ignition of LOX-LCH4 Propellants

No cryogenic Reaction Control System (RCS) has ever flown in space. Cryogenic propellants are baselined by HLS and CLPS partners and are the key use case for future ISRU manufactured propellants. A reliable LOX/LCH 4 RCS is an enabling technology for human Lunar and Mars exploration. In previous thermal vacuum (<275 F, <10 torr) testing at NASA GRC Plum Brook, the team uncovered anomalous LOX/LCH4 engine ignition phenomena where flame kernels quenched at these ultra cold hardware temperatures, leading to many pulses where the engines would not light. In 2022, the project was able to recreate the no light condition with an upgraded Frost-Mint test stand at JSC. This project implemented test stand improvements and procured propellants and follow on engine components for a hot fire campaign beginning in November 2024 which will attempt to ignite the RCS engine at ultra cold vacuum conditions by modifying the engine mixture ratio. New modeling techniques were implemented to account for past no lights and are an enabling method to make lunar surface go no go predictions based on hardware conditions. This was enabled by significant improvements to the Frost Mint system, which reduced moisture build up and leaks, increased propellant availability, leading to more attempts at thermal vacuum hot-fires.

Propulsion↗

NRAP-Open-IAM: FutureGen2 Component Models

This report describes the development and testing of three component models for NRAP-Open-IAM, the National Risk Assessment Partnership’s open-source integrated assessment model. The FutureGen2 Lookup Table Reservoir component model is based on interpolation of data from a set of lookup tables. The lookup tables contain pressures and saturations predicted by multiphase flow simulations performed with a reservoir simulator. The FutureGen2 Above Zone Monitoring Interval (AZMI) component is a surrogate model that can be used to estimate the impact that carbon dioxide (CO 2 ) and brine leaks from the CO 2 storage reservoir at the FutureGen 2.0 site might have had on overlying aquifers or monitoring units were a leak to occur. The model estimates the size of “impact plumes” according to five metrics: pH, Total Dissolved Solids (TDS), pressure, dissolved CO 2 and temperature. The FutureGen2 Aquifer component is similar, but is limited to four metrics: pH, Total Dissolved Solids (TDS), pressure, and dissolved CO 2 . The input parameters for each model are the same, but the Aquifer component is applicable to depths between 100 m and 700 m and the AZMI component is applicable from depths between 700 m and 1050 m.

42 ENGINEERING↗

Studies of acoustic-electric feed-throughs for power transmission through structures

There are numerous engineering design problems where the use of wires to transfer power and communicate data thru the walls of a structure is prohibitive or significantly difficult that it may require a complex design. Using physical feedthroughs in such systems may make them susceptible to leakage of chemicals or gasses, loss of pressure or vacuum, as well as difficulties in providing adequate thermal or electrical insulation. Moreover, feeding wires thru a wall of a structure reduces the strength of the structure and makes the structure prone to cracking due to fatigue that can result from cyclic loading and stress concentrations. One area that has already been identified to require a wireless alternative to electrical feedthroughs is the container of the Mars Sample Return Mission, which will need wireless sensors to sense a pressure leak and to avoid potential contamination. The idea of using elastic or acoustic waves to transfer power was suggested recently by [Y. Hu, et al., July 2003]. This system allows for the avoidance of cabling or wiring. The technology is applicable to the transfer of power for actuation, sensing and other tasks inside any sealed container or vacuum/pressure vessel. An alternative approach to the modeling presented previously [Sherrit et a., 2005] used network analysis to solve the same problem in a clear and expandable manner. Experimental tests on three different designs of these devices were performed. The three designs used different methods of coupling the piezoelectric element to the wall. In the first test the piezoelectric material was bolted using a backing structure. In the second test the piezoelectric was clamped after the application of grease and finally the piezoelectric element was attached using a conductive epoxy. The mechanical clamp with grease produced the highest measured efficiency of 53% however this design was the least practical from a fabrication viewpoint. The power transfer efficiency of conductive epoxy joint was 40% and the stress bolts (12%).

ultrasonics↗