Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Dynamics of McMillan mappings II. axially symmetric map

Here, in this article, we investigate the transverse dynamics of a single particle in a model integrable accelerator lattice, based on a McMillan axially-symmetric electron lens. Although the McMillan e-lens has been considered as a device potentially capable of mitigating collective space charge forces, some of its fundamental properties have not been described yet. The main goal of our work is to close this gap and understand the limitations and potentials of this device. It is worth mentioning that the McMillan axially symmetric map provides the first-order approximations of dynamics for a general linear lattice plus an arbitrary thin lens with motion separable in polar coordinates. Therefore, advancements in its understanding should give us a better picture of more generic and not necessarily integrable round beams. In the first part of the article, we classify all possible regimes with stable trajectories and find the canonical action-angle variables. This provides an evaluation of the dynamical aperture, Poincaré rotation numbers as functions of amplitudes, and thus determines the spread in nonlinear tunes. Also, we provide a parameterization of invariant curves, allowing for the immediate determination of the map image forward and backward in time. The second part investigates the particle dynamics as a function of system parameters. We show that there are three fundamentally different configurations of the accelerator optics causing different regimes of nonlinear oscillations. Each regime is considered in great detail, including the limiting cases of large and small amplitudes. In addition, we analyze the dynamics in Cartesian coordinates and provide a description of observable variables and corresponding spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-J-199: A Software Tool for Quality Assurance of Online Replanning with MR-Linac

Purpose: To develop a quality assurance software tool, ArtQA, capable of automatically checking radiation treatment plan parameters, verifying plan data transfer from treatment planning system (TPS) to record and verify (R&V) system, performing a secondary MU calculation considering the effect of magnetic field from MR-Linac, and verifying the delivery and plan consistency, for online replanning. Methods: ArtQA was developed by creating interfaces to TPS (e.g., Monaco, Elekta), R&V system (Mosaiq, Elekta), and secondary MU calculation system. The tool obtains plan parameters from the TPS via direct file reading, and retrieves plan data both transferred from TPS and recorded during the actual delivery in the R&V system database via open database connectivity and structured query language. By comparing beam/plan datasets in different systems, ArtQA detects and outputs discrepancies between TPS, R&V system and secondary MU calculation system, and delivery. To consider the effect of 1.5T transverse magnetic field from MR-Linac in the secondary MU calculation, a method based on modified Clarkson integration algorithm was developed and tested for a series of clinical situations. Results: ArtQA is capable of automatically checking plan integrity and logic consistency, detecting plan data transfer errors, performing secondary MU calculations with or without a transverse magnetic field, and verifying treatment delivery. The tool is efficient and effective for pre- and post-treatment QA checks of all available treatment parameters that may be impractical with the commonly-used visual inspection. Conclusion: The software tool ArtQA can be used for quick and automatic pre- and post-treatment QA check, eliminating human error associated with visual inspection. While this tool is developed for online replanning to be used on MR-Linac, where the QA needs to be performed rapidly as the patient is lying on the table waiting for the treatment, ArtQA can be used as a general QA tool in radiation oncology practice. This work is partially supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

Beam Line Design and Beam Physics Study of Energy Recovery Linac Free Electron Laser at Peking University

Energy recovering linac (ERL) offers an attractive alternative for generating intense beams of charged particles by approaching the operational efficiency of a storage ring while maintaining the superior beam quality typical of a linear accelerator. In ERLs, the decelerated beam cancels the beam loading effects of the accelerated beam with high repetition rate. Therefore, ERLs can, in principle, accelerate very high average currents with only modest amounts of RF power. So the efficiency of RF power to beam is much higher. Furthermore, the energy of beam to dump is lower, so it will reduce dump radiation. With the successful experiments in large maximum-to-injection energy ratio up to 51:1 and high power FEL up to 14kW, the use of ERL, especially combining with superconducting RF technology, provides a potentially powerful new paradigm for generation of the charged particle beams used in MW FEL, synchrotron radiation sources, high-energy electron cooling devices and so on. The 3+1/2 DC-SC photo injector and two 9cell TESLA superconducting cavity for IR SASE FEL in PKU provides a good platform to achieve high average FEL with Energy Recovery. The work of this thesis is on Beam line design and Beam dynamics study of Energy Recovery Linac Free Electron Laser for Peking University. It is the upgrade of PKU facility, which is under construction. With ERL, this facility can work in CW mode, so it can operate high average beam current without RF power constraint in main linac and generate high average FEL power. Moreover, it provides a test facility to study the key technology in ERL. System parameters are optimized for PKU ERL-FEL. The oscillation FEL output power is studied with different bunch charge, transverse emittance, bunch length and energy spread. The theory of optimal RF power and Q{sub ext} with ERL and without ERL is analyzed and applied to PKU injector and linac including microphonic effect. pace charge effect in the injector and merger is studied for beam energy at ~5MeV. Simulation shows that in the 3+1/2 DC- C injector, there is a region the beam could be over focused by RF electromagnetic field and the transverse emittance in the transport line up to linac will increase instantly due to over focusing. In order to eliminate this effect on beam emittance, several solutions are investigated to avoid over focusing. This result is very important for beam loading experiment for low bunch charge operation. Meanwhile, different merger structures are compared in terms of error sensitivity and emittance increase with space charge effect. In recirculation beam line, a new symmetric 180{degree} arc structure is designed. It fulfills the achromatic condition and adjustable bunch compression. These two parameters are controlled by different Quads knob. With this novel structure, the recirculation lattice can achieve path length adjustment, bunch compression and decompression in a large range. With beamline error, the beam central orbit will deviate from the designed trajectory. An orbit correction system is optimized, which balances between cost and performance of orbit after correction at design level. Different methods are used to estimate its robustness. The BBU instability, especially multi-pass BBU imposed a potentially severe limitation to the average current that can be accelerated in an ERL. Simulation gives the harmful HOMs and predicts that the threshold average current in this machine is much higher than the possible operation current. This work is based on the existing facility in PKU, so it provides guidelines for the facility operation and upgrade in the future. The theoretical analysis of ERL requirement and FEL requirement on beam transport line and beam property paves the way for future ERL research.

43 PARTICLE ACCELERATORS↗

Ground Movement in SSRL Ring

Users of the Stanford Synchrotron Radiation Lightsource (SSRL) are being affected by diurnal motion of the synchrotron's storage ring, which undergoes structural changes due to outdoor temperature fluctuations. In order to minimize the effects of diurnal temperature fluctuations, especially on the vertical motion of the ring floor, scientists at SSRL tried three approaches: painting the storage ring white, covering the asphalt in the middle of the ring with highly reflective Mylar and installing Mylar on a portion of the ring roof and walls. Vertical motion in the storage ring is measured by a Hydrostatic Leveling System (HLS), which calculates the relative height of water in a pipe that extends around the ring. The 24-hr amplitude of the floor motion was determined using spectral analysis of HLS data, and the ratio of this amplitude before and after each experiment was used to quantitatively determine the efficacy of each approach. The results of this analysis showed that the Mylar did not have any significant effect on floor motion, although the whitewash project did yield a reduction in overall HLS variation of 15 percent. However, further analysis showed that the reduction can largely be attributed to a few local changes rather than an overall reduction in floor motion around the ring. Future work will consist of identifying and selectively insulating these local regions in order to find the driving force behind diurnal floor motion in the storage ring.

43 PARTICLE ACCELERATORS↗

Frequency choice of eRHIC SRF linac

eRHIC is a FFAG lattice-based multipass ERL. The eRHIC SRF linac has been decided to change from 422 MHz 5-cell cavity to 647 MHz 5-cell cavity. There are several considerations affecting the frequency choice for a high-current multipass-ERL: the beam structure, bunch length, energy spread, beam-break-up (BBU) threshold, SRF loss considerations. Beyond the physics considerations, cost and complexity or risk is an important consideration for the frequency choice, especially when we are designing a machine to be built in a few years. Although there are some benefits of using a 422 MHz cavity for eRHIC ERL, however, there are some very critical drawbacks, including lack of facilities to fabricate a 422 MHz 5-cell cavity, very few facilities to process such a cavity and no existing facility to test the cavity anywhere. As the cavity size is big and its weight is large, it is difficult to handle it during fabrication, processing and testing, and no one has experience in this area. As the cavity size is large, the cryomodule becomes big as well. All of these considerations drive the risk of building eRHIC ERL with 422 MHz cavities to a very high level. Therefore, a decision was made to change the frequency of main linac to be 647 MHz 5-cell cavities. This note will compare these two linacs: 422MHz 5-cell cavity linac and 647Mz 5-cell cavity SRF linac, from both practical point of view and physics point of view.

43 PARTICLE ACCELERATORS↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 08: Retrospective Dose Accumulation Workflow in Head and Neck Cancer Patients Using RayStation 4.5.2

Purpose: We have developed a semi-automated dose accumulation workflow for Head and Neck Cancer (HNC) patients to evaluate volumetric and dosimetric changes that take place during radiotherapy. This work will be used to assess how dosimetric changes affect both toxicity and disease control, hence inform the feasibility and design of a prospective HNC adaptive trial. Methods: RayStation 4.5.2 features deformable image registration (DIR), where structures already defined on the planning CT image set can be deformably mapped onto cone-beam computed tomography (CBCT) images, accounting for daily treatment set-up shifts and changes in patient anatomy. The daily delivered dose can be calculated on each CBCT and mapped back to the planning CT to allow dose accumulation. The process is partially automated using Python scripts developed in collaboration with RaySearch. Results: To date we have performed dose accumulation on 18 HNC patients treated at our institution during 2013–2015 under REB approval. Our semi-automated process establishes clinical feasibility. Generally, dose accumulation for the entire treatment course of one case takes 60–120 minutes: importing all CBCTs requires 20–30 minutes as each patient has 30 to 40 treated fractions; image registration and dose accumulation require 60–90 minutes. This is in contrast to the process without automated scripts where dose accumulation alone would take 3–5 hours. Conclusions: We have developed a reliable workflow for retrospective dose tracking in HNC using RayStation. The process has been validated for HNC patients treated on both Elekta and Varian linacs with CBCTs acquired on XVI and OBI platforms respectively.

60 APPLIED LIFE SCIENCES↗

Testable dark energy predictions from current data

Given a class of dark energy models, constraints from one set of cosmic acceleration observables make predictions for other observables. Here we present the allowed ranges for the expansion rate H(z), distances D(z), and the linear growth function G(z) (as well as other, derived growth observables) from the current combination of cosmological measurements of supernovae, the cosmic microwave background, baryon acoustic oscillations, and the Hubble constant. With a cosmological constant as the dark energy and assuming near-minimal neutrino masses, the growth function is already predicted to better than 2% precision at any redshift, with or without spatial curvature. Direct measurements of growth that match this precision offer the opportunity to stringently test and potentially rule out a cosmological constant. While predictions in the broader class of quintessence models are weaker, it is remarkable that they are typically only a factor of 2-3 less precise than forecasted predictions for future space-based supernovae and Planck CMB measurements. In particular, measurements of growth at any redshift, or the Hubble constant H{sub 0}, that exceed {Lambda}CDM predictions by substantially more than 2% would rule out not only a cosmological constant but also the whole quintessence class, with or without curvature and early dark energy. Barring additional systematic errors hiding in the data, such a discovery would require more exotic explanations of cosmic acceleration such as phantom dark energy, dark energy clustering, or modifications of gravity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Field Cancellation Algorithm for Constructing Economical Planar Permanent Magnet (PM) Multipoles With Large High Quality Field Apertures

In recent years studies have been initiated on a new class of multipole field generators consisting of cuboid planar permanent magnet (PM) pieces arranged in biplanar arrays of 2-fold rotational symmetry. These structures, first introduced for Free Electron Laser (FEL) applications, are based on reducing the rotational symmetry of conventional N-pole field generators from N-fold to 2-fold. One consequence of this reduction is a large higher-multipole content in a planar PM multipole's field at distances relatively close to the structure's axis, making it generally unsuitable for applications requiring a large high-quality field aperture. In this paper we outline an economical field-cancellation algorithm that can substantially decrease the harmonic content of a planar PM's field without breaking its biplanar geometry or 2-fold rotational symmetry. An economical field-cancellation algorithm has been described which will allow the fabrication of bi-planar quadrupoles and sextupoles with high-quality fields using a manageably small number of PM pieces. For higher order N-poles the number of pieces required to cancel a given number of successively-higher multipole components will also increase linearly; nevertheless, the practicability of fabricating octupoles and higher N-poles of this type should be considered a subject of continuing r&d. Since the removal of a large number of successive multipole components essentially increases the transverse region over which the N-pole's field is dominated by its leading N-pole field component, the fabrication of quadrupoles and sextupoles of the type described in this paper should lead to their introduction in storage ring applications. One potentially important application in this area is as distributed focusing elements installed into very-short-period, small-gap undulators (e.g., as a FODO lattice). The installation is rendered feasible by the very small vertical height of the biplanar N-poles (on the order of a millimeter), which, notwithstanding, doesn't prevent them from attaining focusing gradients on the order of several hundred T/m. If proven, this would allow short-period undulators of substantial length (viz., >>b) to be operated on storage rings, potentially transforming the optimality and economy of synchrotron radiation sources toward more favorable regimes.

43 PARTICLE ACCELERATORS↗

The proton form factor measurements at Jefferson Lab, past and future

Use of the double-polarization technique to obtain the elastic nucleon form factors has resulted in a dramatic improvement of the quality of two of the four nucleon electromagnetic form factors, G{sub Ep} and G{sub En}. It has also changed our understanding of the proton structure, having resulted in a distinctly different Q{sup 2}-dependence for both G{sub Ep} and G{sub Mp}, contradicting the prevailing wisdom of the 1990’s based on cross section measurements, namely that G{sub Ep} and G{sub Mp} obey a “scaling” relation μG{sub Ep} ∼ G{sub Mp}. A related consequence of the faster decrease of G{sub Ep} revealed by the Jefferson Lab (JLab) polarization results was the disappearance of the early scaling F{sub 2}/F{sub 1} ∼ 1/Q{sup 2} predicted by perturbative QCD. In three experiments, GEp(1), GEp(2) and GEp(3), in Halls A and C at JLab, the ratio of the proton’s electromagnetic elastic form factors, G{sub Ep}/G{sub Mp}, was measured up to four momentum transfer Q{sup 2} of 8.5 GeV{sup 2} with high precision, using the recoil polarization technique. The initial discovery that the proton form factor ratio measured in these three experiments decreases approximately linearly with four-momentum transfer, Q{sup 2}, for values above ∼ 1 GeV{sup 2}, was modified by the GEp(3) results, which suggests a slowing down of this decrease. There is an approved experiment, GEp(5), to continue these measurements to 15 GeV{sup 2}. A dedicated experimental setup, the super bigbite spectrometer (SBS), will be built for this purpose. It will be equipped with a new focal plane polarimeter to measure the polarization of the recoil protons. In this presentation, I will review the status of the proton elastic electromagnetic form factors, mention succinctly a number of theoretical approaches to describe results and show some features required for the future GEp(5) experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of photoelastic modulator based dichrometers: maintaining constant phase across the spectrum

Photoelastic modulators can alter the polarization state of a beam of ultraviolet, visible or infrared photons by means of periodic stress-induced differences in the refractive index of a transparent material that forms the optical element of the device and is isotropic in the absence of stress. Furthermore, they have found widespread application in instruments that characterize or alter the polarization state of a beam in fields as diverse as astronomy, structural biology, materials science and ultraviolet lithography for the manufacture of nano-scale integrated circuits. Measurement of circular dichroism, the differential absorption of left- and right circularly polarized light, and of strain-induced birefringence of optical components are major applications. Instruments using synchrotron radiation and photoelastic modulators with CaF 2 optical elements have extended circular dichroism measurements down to wavelengths of about 130 nm in the vacuum ultraviolet. Maintaining a constant phase shift between two orthogonal polarization states across a spectrum requires that the amplitude of the modulated stress be changed as a function of wavelength. For commercially available photoelastic modulators, the voltage that controls the amplitude of modulation required to produce a specified phase shift, which is a surrogate for the stress modulation amplitude, has been shown to be an approximately linear function of wavelength in the spectral region where the optical element is transparent. But, extrapolations of such straight lines cross zero voltage at a non-zero wavelength, not at zero-wavelength. For modulators with calcium fluoride and fused silica optical elements, the zero-crossing wavelength is always in the spectral region where the optical element of the modulator strongly absorbs the incident radiation, and at a wavelength less than the longest-wavelength apparent resonance deduced from experimental values of the refractive index fit to the Sellmeier equation. Using a model that relates the refractive indices of a stressed optical element to the refractive index of its unstressed state, an expression for the modulator control voltage was derived that closely fits the experimental data. Our result provides a theoretical rational for the apparently linear constant-phase programming voltage, and thus provides theoretical backing for the calibration procedure frequently used for these modulators. Lastly there are other factors that can influence the calibration of a photoelastic modulator, including temperature and atmospheric pressure, are discussed briefly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-82: Improving CT Image Quality for Radiation Therapy Using Iterative Reconstruction Algorithms and Slightly Increasing Imaging Doses

Purpose: Iterative reconstruction (IR) algorithms are developed to improve CT image quality (IQ) by reducing noise without diminishing spatial resolution or contrast. For CT in radiation therapy (RT), slightly increasing imaging dose to improve IQ may be justified if it can substantially enhance structure delineation. The purpose of this study is to investigate and to quantify the IQ enhancement as a result of increasing imaging doses and using IR algorithms. Methods: CT images were acquired for phantoms, built to evaluate IQ metrics including spatial resolution, contrast and noise, with a variety of imaging protocols using a CT scanner (Definition AS Open, Siemens) installed inside a Linac room. Representative patients were scanned once the protocols were optimized. Both phantom and patient scans were reconstructed using the Sinogram Affirmed Iterative Reconstruction (SAFIRE) and the Filtered Back Projection (FBP) methods. IQ metrics of the obtained CTs were compared. Results: IR techniques are demonstrated to preserve spatial resolution as measured by the point spread function and reduce noise in comparison to traditional FBP. Driven by the reduction in noise, the contrast to noise ratio is doubled by adopting the highest SAFIRE strength. As expected, increasing imaging dose reduces noise for both SAFIRE and FBP reconstructions. The contrast to noise increases from 3 to 5 by increasing the dose by a factor of 4. Similar IQ improvement was observed on the CTs for selected patients with pancreas and prostrate cancers. Conclusion: The IR techniques produce a measurable enhancement to CT IQ by reducing the noise. Increasing imaging dose further reduces noise independent of the IR techniques. The improved CT enables more accurate delineation of tumors and/or organs at risk during RT planning and delivery guidance.

60 APPLIED LIFE SCIENCES↗

New Perspectives for QCD Physics at the LHC

I review a number of topics where conventional wisdom relevant to hadron physics at the LHC has been challenged. For example, the initial–state and final–state interactions of the quarks and gluons entering perturbative QCD hard–scattering subprocesses lead to the breakdown of traditional concepts of factorization and universality for transverse–momentum–dependent observables at leading twist. The soft–gluon rescattering effects, which are associated with the Wilson line of the propagating partons, also lead to Bjorken–scaling single–spin asymmetries, diffractive deep inelastic scattering, the breakdown of the Lam–Tung leading–twist relation in Drell–Yan reactions, as well as nuclear shadowing. The Gribov–Glauber theory applied to the antishadowing domain predicts that nuclear structure functions depend on the flavor quantum numbers of each quark and antiquark, thus explaining the anomalous nuclear dependence recently observed in deep–inelastic neutrino scattering. Surprisingly, isolated hadrons can be produced at large transverse momentum directly within a hard higher–twist QCD subprocess, rather than from jet fragmentation. The rate is predicted to be significant, even at the LHC. Such “direct” processes can explain the observed deviations from perturbative QCD predictions in measurements of inclusive hadron cross sections at fixed x T = 2p T /√ s , as well as the “baryon anomaly”, the anomalously large proton–to–pion ratio seen in high centrality heavy–ion collisions at RHIC. The intrinsic charm contribution to the proton structure function at high x can explain the large rate for high p T photon plus charm–jet events observed by D 0 at the Tevatron. Intrinsic charm and bottom distributions also imply anomalously large production of charm and bottom jets at high p T at the LHC, as well as a novel mechanism for Higgs and Z 0 production at high x F . Other novel features of QCD are discussed, including the consequences of confinement for quark and gluon condensates and the implications for the QCD contribution to the cosmological constant. Furthermore, the light–front wavefunctions derived in AdS/QCD can be used to calculate jet hadronization at the amplitude level. I also note that the elimination of the renormalization scale ambiguity for the QCD coupling using the scheme–independent BLM method will greatly improve the precision of QCD predictions and thus greatly increase the sensitivity of searches for new physics at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New Measurements of the European Muon Collaboration Effect in Very Light Nuclei

New Jefferson Lab data are presented on the nuclear dependence of the inclusive cross section from {sup 2}H, {sup 3}He, {sup 4}He, {sup 9}Be and {sup 12}C for 0.3<x<0.9, Q{sup 2}{approx_equal}3-6 GeV{sup 2}. These data represent the first measurement of the EMC effect for {sup 3}He at large x and a significant improvement for {sup 4}He. The data do not support previous A-dependent or density-dependent fits to the EMC effect and suggest that the nuclear dependence of the quark distributions may depend on the local nuclear environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of Weak Intermolecular Interactions on the Molecular Isomerism of Tricobalt Metal Chains

Depending on the number of interstitial solvent molecules, n, crystals of the linear chain compound Co3(dipyridylamide)4Cl2{center_dot}nCH2Cl2 adopt either symmetrical or unsymmetrical metal chain structures. We explore here the possible reasons for such behavior using Hirshfeld surface analysis of intermolecular interactions as well as the charge density determined from 100(1) K X-ray diffraction data on the unsymmetrical complex Co3(dipyridylamide)4Cl2{center_dot}2.11CH2Cl2, u-1, and crystal structures of u-1 determined from single crystal synchrotron X-ray diffraction data at 20, 150, and 300 K. The new crystal structures are compared with previous structural results on a crystal with slightly different solvent content. This change in solvent content only affects the bond distances to atom Co(3), which are also strongly affected by temperature changes due to a spin crossover transition. Large differences in intermolecular interactions are revealed by the Hirshfeld surface analysis between symmetrical (s-1) and unsymmetrical (u-1) crystal solvates, suggesting that the molecular isomerism is strongly influenced by crystal packing effects. Topological analysis of the static electron density of u-1 suggests that there is direct metal-metal bonding for both the shorter Co(1)-Co(2) and the longer Co(2)-Co(3) contact. The approximate description of the system as a (Co2)2+-dimer and an isolated Co2+-ion is reflected in the character of the metal-ligand interactions, which are more ionic for the isolated Co(3) atom, and the topological charges Co(1)+0.50, Co(2)+0.77, and Co(3)+1.36. The two termini of u-1 are found to be very different, both in terms of structural surroundings as well as topology. The central Co(2) atom is similar to a cobalt atom in a tetragonally distorted octahedral environment resulting in preferred occupancy in the t2g orbitals. The Co(1) atom has significant deformation in the xz and yz planes (z along the chain axis, x and y toward ligands) reflecting covalent interactions with the terminal chlorine atom Cl(1). The Co(3) atom has a relatively high occupancy of the dx2-y2 orbital and a relatively low occupancy of the dxy orbital confirming that these orbitals are involved in the spin crossover process and predominantly responsible for the observed variation in bond lengths with temperature.

36 MATERIALS SCIENCE↗

SU-E-T-213: Initial Experience with VMAT Plan and Delivery Verification Using a DICOM-RT Framework and Linac Delivery Log Files

Purpose: Mobius3D/MobiusFX (M3D/MFX), a commercial DICOM-RT based plan and delivery verification system, was used to compare calculated and delivered volumetric modulated arc therapy (VMAT) dose distributions using TrueBeam delivery log files (TrajectoryLogs). Methods: M3D/MFX utilizes measured linac commissioning data to generate institution specific beam models for evaluating planned and delivered dose distributions. 30 RapidArc prostate plans and 30 head and neck SmartArc plans were used in this study. For every plan, CT images, contoured structure sets, RT-plan, and RT-dose files were exported to M3D, which recalculated the patients’ planning CT dose distributions using a collapsed-cone-convolutionsuperposition algorithm. MFX utilized the acquired TrajectoryLogs to compute patients’ delivered dose distributions based on actual treatment delivery parameters. The agreement between computed and delivered dose distributions was evaluated utilizing a (3%, 3mm) global 3D-gamma analysis and dose-volume histogram changes for targets and organs at risk. Results: Excellent 3D-gamma agreements were observed for all VMAT plans. On average, for computed and delivered RapidArc and SmartArc plans the gamma passing rates were (99.0%±1.4%) and (96.8%±1.8%), respectively. The average difference for primary target prescription dose percent-coverage between calculated and delivered plans was (− 0.09%±2.52%) for RapidArc and (−2.71%±4.62%) for SmartArc cases. Similarly, the planning target mean dose differences were (1.38%±0.96%) for RapidArc and (1.17%±0.72%) for SmartArc plans. For the prostate plans, the calculated and delivered variations of the maximum dose for a 2cc volume for bladder and rectum were (1.32%±1.26%) and (0.65%±1.44%), respectively. The spinal-cord 2cc maximum dose differences of (3.26%±1.68%) were observed for the SmartArc plans. Conclusions: Clinical quality assurance practice based on linac treatment log files for verification of delivered 3D dose distributions in the patients’ geometries represents a paradigm shift from dose measurements in a phantom. This approach captures treatment planning beam modeling differences as well as the linac uncertainties during treatment delivery of the plan.

60 APPLIED LIFE SCIENCES↗

Preliminary waste management plan of European spallation

The European Spallation Source (ESS) is the European common effort in designing and building a next generation large-scale user facility for studies of the structure and dynamics of materials. The proposed schematic layout of the ESS facility is based on a linear driver (linac) directing the proton beam (5 MW of 2.5 GeV) of 2.8 ms long pulses with a 20 Hz on a tungsten target where neutrons are produced via spallation reactions. Further the neutrons will be moderated to thermal and sub-thermal energies in a couple of moderators placed around the target. The moderators feed 22 beamlines guiding the neutrons to the scattering instruments, mainly for neutron scattering research, as has been previously mentioned. The objective of this work is to develop a waste management plan for ESS facility. In this respect two important aspects are analyzed. First the present status of the problem is outlined as follow. Estimate types and quantities of waste that the ESS project will generate at different stages: commission, operation, decommissioning were derived using: i) precise Monte Carlo calculations ii) scaling the activity from the operation experience of the existing spallation source installations for waste such it is difficult to predict level of activation or for components of the facility in stage of the preconceptual model. Associated waste treatment/conditioning options and final disposal route were further analyzed in order to define the waste type and packet descriptions in agreement with Swedish regulations and policy. It was found that the compilation of completely new waste type descriptions for qualification of the ESS waste for disposal will be necessary. Particular attention was devoted to 'problematic waste' as Beryllium reflector, C-14 from graphite used as core zone of the beam-dump and collimators or waste arising from the purification systems of both Helium and water cooling circuits. Management of waste on ESS site: collection/segregation systems, characterization system, storage options, is also described. In the second step, the acquired information is used for planning and implementing actions involving all participants (ESS, treatment facility operator, disposal operator, regulatory body and other authorized authorities). (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Verification and validation of linear gyrokinetic simulation of Alfven eigenmodes in the DIII-D tokamak

A verification and validation study is carried out for a sequence of reversed shear Alfven instability time slices. The mode frequency increases in time as the minimum (q{sub min}) in the safety factor profile decreases. Profiles and equilibria are based upon reconstructions of DIII-D discharge (no. 142111) in which many such frequency up-sweeping modes were observed. Calculations of the frequency and mode structure evolution from two gyrokinetic codes, GTC and GYRO, and a gyro-Landau fluid code TAEFL are compared. The experimental mode structure of the instability was measured using time-resolved two-dimensional electron cyclotron emission imaging. The three models reproduce the frequency upsweep event within {+-}10% of each other, and the average of the code predictions is within {+-}8% of the measurements; growth rates are predicted that are consistent with the observed spectral line widths. The mode structures qualitatively agree with respect to radial location and width, dominant poloidal mode number, ballooning structure, and the up-down asymmetry, with some remaining differences in the details. Such similarities and differences between the predictions of the different models and the experimental results are a valuable part of the verification/validation process and help to guide future development of the modeling efforts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-490: Separating Effects Influencing Detector Response in Small MV Photon Fields

Purpose: Different detector properties influence their responses especially in field sizes below the lateral electron range. Due to the finite active volume, the detector density and electron perturbation at other structural parts, the response factor is in general field size dependent. We aimed to visualize and separate the main effects contributing to detector behavior for a variety of detector types. This was achieved in an experimental setup, shielding the field center. Thus, effects caused by scattered radiation could be examined separately. Methods: Signal ratios for field sizes down to 8 mm (SSD 90 cm, water depth 10 cm) of a 6MV beam from a Siemens Primus LINAC were recorded with several detectors: PTW microDiamond and PinPoint ionization chamber, shielded diodes (PTW P-60008, IBA PFD and SNC Edge) and unshielded diodes (PTW E-60012 and IBA SFD). Measurements were carried out in open fields and with an aluminum pole of 4 mm diameter as a central block. The geometric volume effect was calculated from profiles obtained with Gafchromic EBT3 film, evaluated using FilmQA Pro software (Ashland, USA). Results: Volume corrections were 1.7% at maximum. After correction, in small open fields, unshielded diodes showed a lower response than the diamond, i.e. diamond detector over-response seems to be higher than that for unshielded diodes. Beneath the block, this behavior was amplified by a factor of 2. For the shielded diodes, the overresponse for small open fields could be confirmed. However their lateral response behavior was strongly type dependent, e.g. the signal ratio dropped from 1.02 to 0.98 for the P-60008 diode. Conclusion: The lateral detector response was experimentally examined. Detector volume and density alone do not fully account for the field size dependence of detector response. Detector construction details play a major role, especially for shielded diodes.

61 RADIATION PROTECTION AND DOSIMETRY↗