At least 1,153 records · Page 64

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design. This revision models the individual maximum fan reduced flow capacity from 38,000 cfm to 31,200 cfm; no changes to the duct design are made.

42 ENGINEERING↗

Modeling atomically mixed graded density impactors

Graded density impactors (GDIs) are multi-material composite impactors used in gas gun experiments to tailor the drive conditions imparted to a sample test material. Previous graded density impactors generally rely on thin, but discrete, layers of different materials. The thinner and the greater number of layers will result in smoother compression. Taken to the limit of very thin layers would be pure material 1 at one surface, such as the front surface of an impactor, smoothly transitioning at the atomic scale to pure material 2 on the back surface. Such an impactor can initially shock, then smoothly compresses a material during a dynamic experiment. This type of experiment can serve to explore a larger region of thermodynamic space than a single or even multi-shock experiments. An overview of how graded density impactors are made is reviewed and sample results are given. Additionally, a strategy for modeling these kinds of impactors is presented. The length scales of constituent mixing are given from the experimental build through electrochemical-deposition. Equation of state models for pure constituents and their subsequent mixtures are presented. It is demonstrated that the time scales for pressure and temperature equilibration, for atomically mixed GDIs, are short enough to be a justifiable closure for the resulting multiphase flow. Furthermore, we present simulation results of dynamic shock followed by a ramp compression, utilizing a silver/gold graded density impactor, onto a tantalum sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal Voltage Reference for Droop-Based DERs in Distribution Systems

Due to the newly issued standards on distributed energy resources (DERs), the droop-based operation modes (Q-V and P-V droops) become a requirement for all the interconnected DER units at the distribution level. Voltage references of the DER units can be assigned to improve the operational behavior of the distribution system in the smart grid context. This paper presents a novel formulation for optimally setting voltage reference of the droop-based DER units in distribution systems with the objective of minimizing the system ohmic loss. This problem is formulated as a mixed-integer quadratic convex optimization problem in MATLAB and solved by the MATLAB and CPLEX solvers. The IEEE 123-bus system and the EPRI test system Ckt5 are used to validate the proposed formulation. The result obtained from the proposed formulation is compared with the result of the original problem solved by the heuristic method. Based on the numerical study results, system loss can be reduced after the proposed voltage reference assignment. The computational expense of the new formulation is also much lower than that of the heuristic approach.

distributed energy resource integration↗

Analysis of the ANL Test Method for 6CVS Containment Vessels

In the fall of 2010, Argonne National Laboratory (ANL) contracted with vendors to design and build 6CVS containment vessels as part of their effort to ship Fuel Derived Mixed Fission Product material. The 6CVS design is based on the Savannah River National Laboratory's (SRNL) design for 9975 and 9977 six inch diameter containment vessels. The main difference between the designs is that the 6CVS credits the inner O-ring seal as the containment boundary while the SRNL design credits the outer O-ring seal. Since the leak test must be done with the inner O-ring in place, the containment vessel does not have a pathway for getting the helium into the vessel during the leak test. The leak testing contractor was not able to get acceptable leak rates with the specified O-ring, but they were able to pass the leak test with a slightly larger O-ring. ANL asked the SRNL to duplicate the leak test vendor's method to determine the cause of the high leak rates. The SRNL testing showed that the helium leak indications were caused by residual helium left within the 6CVS Closure Assembly by the leak test technique, and by helium permeation through the Viton O-ring seals. After SRNL completed their tests, the leak testing contractor was able to measure acceptable leak rates by using the slightly larger O-ring size, by purging helium from the lid threads, and by being very quick in getting the bell jar under a full vacuum. This paper describes the leak test vendor's test technique, and other techniques that could be have been used to successfully leak test the 6CVS's.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Materials for Mercury 50 Gas Turbine Combustion System

Solar Turbines Incorporated (Solar), under cooperative agreement number DE-FC26-0CH11049, has conducted development activities to improve the durability of the Mercury 50 combustion system to 30,000 hours life and reduced life cycle costs. This project is part of Advanced Materials in the Advanced Industrial Gas Turbines program in DOE's Office of Distributed Energy. The targeted development engine was the Mercury{trademark} 50 gas turbine, which was developed by Solar under the DOE Advanced Turbine Systems program (DOE contract number DE-FC21-95MC31173). As a generator set, the Mercury 50 is used for distributed power and combined heat and power generation and is designed to achieve 38.5% electrical efficiency, reduced cost of electricity, and single digit emissions. The original program goal was 20,000 hours life, however, this goal was increased to be consistent with Solar's standard 30,000 hour time before overhaul for production engines. Through changes to the combustor design to incorporate effusion cooling in the Generation 3 Mercury 50 engine, which resulted in a drop in the combustor wall temperature, the current standard thermal barrier coated liner was predicted to have 18,000 hours life. With the addition of the advanced materials technology being evaluated under this program, the combustor life is predicted to be over 30,000 hours. The ultimate goal of the program was to demonstrate a fully integrated Mercury 50 combustion system, modified with advanced materials technologies, at a host site for a minimum of 4,000 hours. Solar was the Prime Contractor on the program team, which includes participation of other gas turbine manufacturers, various advanced material and coating suppliers, nationally recognized test laboratories, and multiple industrial end-user field demonstration sites. The program focused on a dual path development route to define an optimum mix of technologies for the Mercury 50 and future gas turbine products. For liner and injector development, multiple concepts including high thermal resistance thermal barrier coatings (TBC), oxide dispersion strengthened (ODS) alloys, continuous fiber ceramic composites (CFCC), and monolithic ceramics were evaluated before down-selection to the most promising candidate materials for field evaluation. Preliminary, component and sub-scale testing was conducted to determine material properties and demonstrate proof-of-concept. Full-scale rig and engine testing was used to validated engine performance prior to field evaluation at a Qualcomm Inc. cogeneration site located in San Diego, California. To ensure that the CFCC liners with the EBC proposed under this program would meet the target life, field evaluations of ceramic matrix composite liners in Centaur{reg_sign} 50 gas turbine engines, which had previously been conducted under the DOE sponsored Ceramic Stationary Gas Turbine program (DE-AC02-92CE40960), was continued under this program at commercial end-user sites under Program Subtask 1A - Extended CFCC Materials Durability Testing. The goal of these field demonstrations was to demonstrate significant component life, with milestones of 20,000 and 30,000 hours. Solar personnel monitor the condition of the liners at the field demonstration sites through periodic borescope inspections and emissions measurements. This program was highly successful at evaluating advanced materials and down-selecting promising solutions for use in gas turbine combustions systems. The addition of the advanced materials technology has enabled the predicted life of the Mercury 50 combustion system to reach 30,000 hours, which is Solar's typical time before overhaul for production engines. In particular, a 40 mil thick advanced Thermal Barrier Coating (TBC) system was selected over various other TBC systems, ODS liners and CFCC liners for the 4,000-hour field evaluation under the program. This advanced TBC is now production bill-of-material at various thicknesses up to 40 mils for all of Solar's advanced backside-cooled combustor liners (Centaur 50, Taurus 60, Mars 100, Taurus 70, Taurus 65, Titan 130, Titan 250 and Mercury 50). This TBC coating system significantly outperformed all other TBC systems evaluated under the program. The initial field unit, with the 40 mil advanced TBC developed under this program, has far exceeded the 4,000-hour requirement of the program, accumulating over 20,000 hours of commercial operation at Qualcomm Inc. in San Diego, CA. The 40 mil advanced TBC remains in excellent condition, with no evidence of chipping or spalling. The engine will continue operation until the unit is due for overhaul at approximately 30,000 hours. The Oxide Dispersion Strengthened (ODS) alloy injector tip testing and evaluation was also successful, however, the ODS injector tip development on this program was terminated, primarily due to the fact that the Mercury 50 injector tip was redesigned (Generation 3) by Combustion Engineering.

33 ADVANCED PROPULSION SYSTEMS↗

RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling of HTTF test PG-26 using RELAP5-3D and SAM

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors (HTGR) with prismatic fuel and reflector blocks [1]. Several tests have been completed at the HTTF including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This summary reports on the analysis of test PG-26 using the INL system code REALP5-3D [2] as well as the ANL system code SAM [3]. Test PG-26 is a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC [4]. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heater banks. The DCC transient was initiated during the 50th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test.

97 MATHEMATICS AND COMPUTING↗

Investigation of an inhomogeneous turbulent mixing model for conditional moment closure applied to autoignition

The present paper examines the case of autoignition of high pressure methane jets in a shock tube over a range of pre-heated air temperatures in engine-relevant conditions. The two objectives of the present paper are: (i) to examine the effect of the inhomogeneous mixing model on the autoignition predictions relative to the results obtained using homogeneous mixing models and (ii) to see if the magnitude of the change can explain the discrepancy between the predictions of ignition delay previously obtained with homogeneous mixing models and the experimental data. The governing equation of the scalar dissipation rate is solved for transient conditions and two different formulations of the same model are tested and compared: one using the linear model for the conditional velocity and one including the gradient diffusion model. The predicted ignition kernel location and time delay over a range of pre-combustion air temperatures are compared with results obtained using two homogeneous turbulent mixing models and available experimental data. The profiles of conditional velocity and the conditional scalar dissipation rate are examined. Issues related to the conditional velocity model are discussed. It is found that the differences in the predictions are due to the mixing model only. The inhomogeneous model using the gradient conditional velocity model produces much larger ignition delays compared to the other models, whereas the inhomogeneous form including the linear model does not produce any significant differences. The effect of the turbulent inhomogeneous model is larger at high air temperatures and decreases with decreasing air temperatures. In comparison with the measured ignition delays, the inhomogeneous-Gradient model brings a small improvement at high air temperatures over the results from the turbulent homogeneous models. At low air temperatures, other parameters need to be investigated in order to bring the predicted ignition delays and locations within the experimental data scatter. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Relationship between operational variables, fundamental physics and foamed cement properties in lab and field generated foamed cement slurries

Foamed cement is a critical component for wellbore stability. The mechanical performance of a foamed cement depends on its microstructure, which in turn depends on the preparation method and attendant operational variables. Determination of cement stability for field use is based on laboratory testing protocols governed by API Recommended Practice 10B-4 (API RP 10B-4, 2015). However, laboratory and field operational variables contrast considerably in terms of scale, as well as slurry mixing and foaming processes. Here in this paper, laboratory and field operational processes are characterized within a physics-based framework. It is shown that the “atomization energy” imparted by the high pressure injection of nitrogen gas into the field mixed foamed cement slurry is – by a significant margin – the highest energy process, and has a major impact on the void system in the cement slurry. There is no analog for this high energy exchange in current laboratory cement preparation and testing protocols. Quantifying the energy exchanges across the laboratory and field processes provides a basis for understanding relative impacts of these variables on cement structure, and can ultimately lead to the development of practices to improve cement testing and performance.

02 PETROLEUM↗

Review of Grey Box/Black Box Data Contamination Metrics on Open and Commercial Models

Dataset contamination is a problem where benchmarks and tasks used to evaluate the capabilities of Large Language Models (LLMs) have been incorporated into the training dataset of the models. This gives a false sense of performance that can overestimate how these models will function on truly unseen data. This problem becomes worse with commercial LLMs with larger and non-accessible training data, so techniques have been developed to try to measure the degree to which a model is contaminated with a benchmark’s data. To understand the effectiveness of these techniques, particularly when evaluating contamination on coding tasks, we review trends and categorize techniques by the degree of access to the model that is required. The research literature on this topic has reported mixed effectiveness of these techniques, so we select a set of black box (text access only) and grey box (access to model loss/probabilities required) techniques and apply them to both commercial and non-commercial models. We implement these metrics as part of a framework to test the contamination of Python code in LLMs to see to what extent we can replicate the effectiveness (or ineffectiveness) of these contamination detection techniques. Though we find mixed results in the capabilities of these metrics to identify contamination, we do observe evidence that they can identify contamination (broadly) in fine-tuned models when both a baseline and fine-tuned model is present. Additionally, similarity metrics were able to identify between contaminated and uncontaminated data even in situations where the data is distributionally similar (e.g., drawn from the same set of code projects).

97 MATHEMATICS AND COMPUTING↗

Summary Report of Laboratory Testing to Establish the Effectiveness of Proposed Treatment Methods for Unremediated and Remediated Nitrate Salt Waste Streams

The inadvertent creation of transuranic waste carrying hazardous waste codes D001 and D002 requires the treatment of the material to eliminate the hazardous characteristics and allow its eventual shipment and disposal at the Waste Isolation Pilot Plant (WIPP). This report documents the effectiveness of two treatment methods proposed to stabilize both the unremediated and remediated nitrate salt waste streams (UNS and RNS, respectively). The two technologies include the addition of zeolite (with and without the addition of water as a processing aid) and cementation. Surrogates were developed to evaluate both the solid and liquid fractions expected from parent waste containers, and both the solid and liquid fractions were tested. Both technologies are shown to be effective at eliminating the characteristic of ignitability (D001), and the addition of zeolite was determined to be effective at eliminating corrosivity (D002), with the preferred option1 of zeolite addition currently planned for implementation at the Waste Characterization, Reduction, and Repackaging Facility. During the course of this work, we established the need to evaluate and demonstrate the effectiveness of the proposed remedy for debris material, if required. The evaluation determined that Wypalls absorbed with saturated nitrate salt solutions exhibit the ignitability characteristic (all other expected debris is not classified as ignitable). Follow-on studies will be developed to demonstrate the effectiveness of stabilization for ignitable Wypall debris. Finally, liquid surrogates containing saturated nitrate salts did not exhibit the characteristic of ignitability in their pure form (those neutralized with Kolorsafe and mixed with sWheat did exhibit D001). As a result, additional nitrate salt solutions (those exhibiting the oxidizer characteristic) will be tested to demonstrate the effectiveness of the remedy.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Grounding our Understanding of the Impacts of Boreal Forest Expansion on Shallow Cumulus Clouds with a Simple Modeling Framework

Abstract The expansion of the boreal forest poleward is a potentially important driver of feedbacks between the land surface and Arctic climate. A growing body of work has highlighted the importance of differences in evaporative resistance between different possible future Arctic land covers, which in turn alters humidity and cloudiness in the boundary layer, for these feedbacks. While thus far this problem has been studied primarily with complex Earth system models, we turn to a locally focused, idealized model capable of diagnosing and testing the sensitivity of first-order processes connecting vegetation, the atmospheric boundary layer, and low clouds in this critical region. This allows us to benchmark the mechanisms and results at the center of predictions from larger-scale simulations. A surface dominated by broadleaf trees, characterized by higher albedo and lower surface evaporative resistance, drives cooling and moistening of the boundary layer relative to a surface of needleleaf trees, characterized by lower albedo and higher surface evaporative resistance. Differences in evaporative resistance between these hypothetical Arctic vegetation covers are of equal importance to changes in albedo for the initial response of the boundary layer to boreal expansion, even with our idealized approach. However, compensation between the elevation of the lifting condensation level (LCL) and more rapid growth of the mixed layer over higher evaporative resistance surfaces can minimize changes in the favorability of shallow clouds over different land cover types under some conditions. We then perform two tests on the sensitivity of this compensating effect, to changes in water availability, represented first by a reduction in boundary layer humidity and then by both a reduction in humidity and soil moisture available to our vegetation surface. Finally, given the importance of this potential LCL–mixed-layer height compensation in our idealized modeling results, we look to determine its relevance in observational data from a field campaign in boreal Finland. These observations do confirm that such a coupling plays an important role in cumulus-topped boundary layers over a needleleaf forest surface. While our results confirm some underlying mechanisms at the center of prior work with Earth system models, they also provide motivation for future work to constrain the impact of boreal forest expansion. This will include both large eddy simulations to examine the impact of processes and feedbacks not resolved by a mixed-layer model, as well as a more systematic evaluation and comparison of relevant observations at the site in Finland and sites from prior boreal field campaigns. Significance Statement Clouds and vegetation are both important components of the climate system that interact across a range of scales. These interactions are central to understanding how changes at the land surface feedback on climate. For example, if a forest expands or recedes, diagnosing how that will impact clouds will determine whether you predict warming or cooling temperatures from that shift in the forest area. These predictions are often made with complex Earth system models, but we look to a more idealized representation of the land–atmosphere system to diagnose how shallow clouds should respond to changes in surface properties with different scenarios of boreal forest expansion at a more foundational level. This both grounds our understanding of previous analysis and provides helpful direction for future studies of this relevant and impactful land cover change.

Meteorology & Atmospheric Sciences↗

Mixed-Metal, Structural, and Substitution Effects of Polyoxometalates on Electrochemical Behavior in a Redox Flow Battery

A pair of redox flow batteries containing polyoxometalates was tested as part of an ongoing program in stationary energy storage. The iron-containing dimer, (SiFe3W9(OH)3O34)2(OH)311-, cycled between (SiFe3W9(OH)3O34)2(OH)311-/(SiFe3W9(OH)3O34)2(OH)314-and (SiFe3W9(OH)3O34)2(OH)317-/(SiFe3W9(OH)3O34)2(OH)314- for the positive and negative electrode, respectively. This compound demonstrated a coulombic efficiency of 83% after 20 cycles with an electrochemical yield (measured discharge capacity as a percentage of theoretical capacity) of 55%. Cyclic voltammetry on the Lindqvist ion, cis-V2W4O194-, showed quasi-reversible vanadium electrochemistry, but tungsten reduction was mostly irreversible. In a flow cell configuration, cis-V2W4O194-had a coulombic efficiency of 45% (for a two-electron process) and an electrochemical yield of 16% after 20 cycles. The poor performance of cis-V2W4O194-was attributed primarily to its higher charge density. Collectively, the results showed that both polyoxometalate size and charge density are both important parameters to consider in battery material performance.

36 MATERIALS SCIENCE↗

Point Sensor Networks Struggle to Detect and Quantify Short Controlled Releases at Oil and Gas Sites

This study evaluated multiple commercially available continuous monitoring (CM) point sensor network (PSN) solutions under single-blind controlled release testing conducted at operational upstream and midstream oil and natural gas (O&G) sites. During releases, PSNs reported site-level emission rate estimates of 0 kg/h between 38 and 86% of the time. When non-zero site-level emission rate estimates were provided, no linear correlation between the release rate and the reported emission rate estimate was observed. The average, aggregated across all PSN solutions during releases, shows 5% of the mixing ratio readings at downwind sensors were greater than the site’s baseline plus two standard deviations. Four of seven total PSN solutions tested during this field campaign provided site-level emission rate estimates with the site average relative error ranging from −100% to 24% for solution D, −100% to −43% for solution E, −25% for solution F (solution F was only at one site), and −99% to 430% for solution G, with an overall average of −29% across all sites and solutions. Of all the individual site-level emission rate estimates, only 11% were within ±2.5 kg/h of the study team’s best estimate of site-level emissions at the time of the releases.

42 ENGINEERING↗

Mixed precision efficiency improvements for multi-physics flow simulations

This report summarizes research activities at Cascade Technologies during February 2020 - November 2020 to support DOE SBIR phase I contract DE-SC0020548. The primary technical objectives of the work are two-fold: a) to establish a theoretical framework to understand the propagation and impact of finite-precision-related errors and b) to quantify the trade-offs between accelerator throughput and solution accuracy through a series of validation tests involving multi-physics flow phenomena.

97 MATHEMATICS AND COMPUTING↗

Electron- and positron-proton elastic scattering in CLAS

There is a significant disagreement between measurements of the proton electric form factor, G{sup p}{sub E}, using Rosenbluth separations and polarization transfer. This disagreement, if not explained, could pose a fundamental challenge to our understanding of electron scattering or proton structure. Two-photon exchange (TPE) processes, although not fully calculable, are the most likely explanation of this disagreement. We will definitively test this assertion by comparing the electron-proton and positron-proton elastic scattering cross section in the Jefferson Lab CLAS. We will make a mixed identical electron and positron tertiary beam by passing a 5.5 GeV primary electron beam through a radiator to make a photon beam and then passing the photon beam through a converter to make electron-positron pairs. Measuring the elastic cross sections simultaneously using identical lepton beams should significantly reduce systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

REMOVING SLUDGE HEELS FROM SAVANNAH RIVER SITE WASTE TANKS BY OXALIC ACID DISSOLUTION

The Savannah River Site (SRS) will remove sludge as part of waste tank closure operations. Typically the bulk sludge is removed by mixing it with supernate to produce a slurry, and transporting the slurry to a downstream tank for processing. Experience shows that a residual heel may remain in the tank that cannot be removed by this conventional technique. In the past, SRS used oxalic acid solutions to disperse or dissolve the sludge heel to complete the waste removal. To better understand the actual conditions of oxalic acid cleaning of waste from carbon steel tanks, the authors developed and conducted an experimental program to determine its effectiveness in dissolving sludge, the hydrogen generation rate, the generation rate of other gases, the carbon steel corrosion rate, the impact of mixing on chemical cleaning, the impact of temperature, and the types of precipitates formed during the neutralization process. The test samples included actual SRS sludge and simulated SRS sludge. The authors performed the simulated waste tests at 25, 50, and 75 C by adding 8 wt % oxalic acid to the sludge over seven days. They conducted the actual waste tests at 50 and 75 C by adding 8 wt % oxalic acid to the sludge as a single batch. Following the testing, SRS conducted chemical cleaning with oxalic acid in two waste tanks. In Tank 5F, the oxalic acid (8 wt %) addition occurred over seven days, followed by inhibited water to ensure the tank contained enough liquid to operate the mixer pumps. The tank temperature during oxalic acid addition and dissolution was approximately 45 C. The authors analyzed samples from the chemical cleaning process and compared it with test data. The conclusions from the work are: (1) Oxalic acid addition proved effective in dissolving sludge heels in the simulant demonstration, the actual waste demonstration, and in SRS Tank 5F. (2) The oxalic acid dissolved {approx} 100% of the uranium, {approx} 100% of the iron, and {approx} 40% of the manganese during a single contact in the simulant demonstration. (The iron dissolution may be high due to corrosion of carbon steel coupons.) (3) The oxalic acid dissolved {approx} 80% of the uranium, {approx} 70% of the iron, {approx} 50% of the manganese, and {approx} 90% of the aluminum in the actual waste demonstration for a single contact. (4) The oxalic acid dissolved {approx} 100% of the uranium, {approx} 15% of the iron, {approx} 40% of the manganese, and {approx} 80% of the aluminum in Tank 5F during the first contact cycle. Except for the iron, these results agree well with the demonstrations. The data suggest that a much larger fraction of the iron in the sludge dissolved, but it re-precipitated with the oxalate added to Tank 5F. (5) The demonstrations produced large volumes (i.e., 2-14 gallons of gas/gallon of oxalic acid) of gas (primarily carbon dioxide) by the reaction of oxalic acid with sludge and carbon steel. (6) The reaction of oxalic acid with carbon steel produced hydrogen in the simulant and actual waste demonstrations. The volume produced varied from 0.00002-0.00100 ft{sup 3} hydrogen/ft{sup 2} carbon steel. The hydrogen production proved higher in unmixed tanks than in mixed tanks.

08 HYDROGEN↗