Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monitor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

On-Line Monitoring and Control of Radiochemical Streams at Spent Fuel Reprocessing Plant

Techniques are needed to provide on-line monitoring and control of the radiochemical processes that are being developed and demonstrated under the Global Nuclear Energy Partnership (GNEP) initiative. The instrumentation used to monitor these processes must be robust and must be able to withstand harsh radiation and chemical environments. A new on-line monitoring system satisfying these requirements featuring Raman spectroscopy combined with a Coriolis and conductivity probes, has been recently developed by our research team. It provides immediate chemical data and flow parameters of high-level radioactive waste streams with high brine/high alkalinity generated during retrieval from Hanford nuclear waste storage tanks. We are currently applying similar methodology for monitoring the radiochemical streams generated at the spent fuel reprocessing plant. The nature of these strems calls for additional spectroscopic information, which can be gained by the utilization of UV-vis-NIR capabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The compressed state Kalman filter for nonlinear state estimation: Application to large-scale reservoir monitoring

Reservoir monitoring aims to provide snapshots of reservoir conditions and their uncertainties to assist operation management and risk analysis. These snapshots may contain millions of state variables, e.g., pressures and saturations, which can be estimated by assimilating data in real time using the Kalman filter (KF). However, the KF has a computational cost that scales quadratically with the number of unknowns, m, due to the cost of computing and storing the covariance and Jacobian matrices, along with their prod-ucts. The compressed state Kalman filter (CSKF) adapts the KF for solving large-scale monitoring problems. The CSKF uses N preselected orthogonal bases to compute an accurate rank-N approximation of the covari-ance that is close to the optimal spectral approximation given by SVD. The CSKF has a computational cost that scales linearly in m and uses an efficient matrix-free approach that propagates uncertainties using N + 1 forward model evaluations, where N << m. Here in this paper we present a generalized CSKF algorithm for nonlin-ear state estimation problems such as CO 2 monitoring. For simultaneous estimation of multiple types of state variables, the algorithm allows selecting bases that represent the variability of each state type. Through synthetic numerical experiments of CO 2 monitoring, we show that the CSKF can reproduce the Kal-man gain accurately even for large compression ratios (m/N). For a given computational cost, the CSKF uses a robust and flexible compression scheme that gives more reliable uncertainty estimates than the ensemble Kalman filter, which may display loss of ensemble variability leading to suboptimal uncertainty estimates.

97 MATHEMATICS AND COMPUTING↗

Methylxanthine Drug Monitoring with Wearable Sweat Sensors

Drug monitoring plays crucial roles in doping control and precision medicine. It helps physicians tailor drug dosage for optimal benefits, track patients' compliance to prescriptions, and understand the complex pharmacokinetics of drugs. Conventional drug tests rely on invasive blood draws. While urine and sweat are attractive alternative biofluids, the state-of-the-art methods require separate sample collection and processing steps and fail to provide real-time information. In this paper, a wearable platform equipped with an electrochemical differential pulse voltammetry sensing module for drug monitoring is presented. A methylxanthine drug, caffeine, is selected to demonstrate the platform's functionalities. Sweat caffeine levels are monitored under various conditions, such as drug doses and measurement time after drug intake. Elevated sweat caffeine levels upon increasing dosage and confirmable caffeine physiological trends are observed. This work leverages a wearable sweat sensing platform toward noninvasive and continuous point-of-care drug monitoring and management.

47 OTHER INSTRUMENTATION↗

Telemetric Catheter-Based Pressure Sensor for Hemodynamic Monitoring: Experimental Experience

The purpose of this study was to evaluate the technical and animal experimental feasibility of a percutaneously implantable pulmonary arterial implant for permanent hemodynamic monitoring. Two systems for measuring pulmonary artery pressure (PAP) as well as pulmonary artery occlusion pressure (PAOP) were developed by modifying a commercially available pulmonary artery catheter (PAC). First, a cable-bound catheter-based system was designed by implementation of a capacitive absolute-pressure sensor in the catheter tip. This system was developed further into a completely implantable telemetric system. The devices were tested in an acute setting in a total of 10 sheep. The implant was placed with its tip in the descending pulmonary artery via the right jugular approach. Results were compared with conventional PAC positioned in the contralateral pulmonary artery using Pearson's correlation coefficients and Bland-Altman plots. Implantation of the monitoring systems was uneventful in 10 animals. Data from two fully functional cable-bound and telemetric pressure monitoring systems were available, with a total of 18,506 measurements. There was an excellent correlation between reference data and the data obtained with the implants (r = 0.9944). Bland-Altman plots indicated a very good agreement between the techniques. We report the development and successful initial test of an implantable catheter-based device for long-term measurement of PAP and PAOP. Both devices may be applicable for hemodynamic monitoring. Further long-term studies for assessing reliability and durability of the device are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Method of Determining the Reliability of Real-Time In-reactor Monitoring of VVER

A methodological approach and the basic tenets for evaluating the reliability of in-reactor monitoring of VVER are presented. The method is based on the statistical analysis of indications in real time and includes methods for evaluating the admissible maximum error of the measurement channels used for monitoring as well as the average value and admissible deviation of indications in groups of parallel monitoring channels, as well as a method of evaluating reliability by comparing the values of a parameter with the regime values. In comparing the indications of a monitoring channel with the indications of other parallel channels, the median value is proposed as the baseline value. The developed method is implemented in the Diagnostika SVRK special software, which has been successfully tested during the commissioning of the No. 1 unit at the Novovoronezh NPP-2.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A new method of relative radiometric calibration for hyperspectral imaging based on skylight monitor

A new method of relative radiometric calibration based on the skylight monitor is presented for airborne hyperspectral remote sensing to eliminate the negative effect on data resulting from the time-varying skylight during a long flight. In terms of large area operation of mapping or spectral imaging, a static radiation model hardly reveals actual cases as external environment keeps changing. Compared with common considerable factors, fluctuation of skylight is the primary one that may observably affect spectral imaging continuously leading to radiation changes upon flight lines. To get rid of the influence of skylight on spectral imagery and monitoring the variation during the flight, we assemble a set of skylight monitor fixed to the aircraft cabin for the sake of recording the semi-spherical skylight keeping synchronization with hyperspectral imaging system and the position and orientation system. The skylight monitor consists of a cosine corrector on the top receiving the skylight, a stable optical fiber and a visible and near-infrared linear array modular spectrometer. The corresponding matched data of skylight with each frame of images is used to correct related digital number after stripe non-uniformity correction, achieving mean relative standard deviation (coefficient of variation or CV) of under 6% for all 256 bands. The final result shows a satisfactory calibrated image of an appropriate evaluation criteria with contrast of the original image.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In Situ Quality Monitoring in AM Using Acoustic Emission: A Reinforcement Learning Approach

Additive manufacturing (AM) has attracted considerable attention in recent years. This technology overcomes the geometrical limits of workpieces produced with the traditional subtractive methods and so gives the opportunity to manufacture highly complex shapes. Unfortunately, the repeatability of the manufacturing process and the monitoring of quality are not reliable enough to be utilized in mass production. The quality monitoring of AM processes in commercial equipment has been largely based on temperature measurements of the process zone or high-resolution imaging of the layers. However, both techniques lack information about the physical phenomena taking place in the depth of the materials medium and this limits their reliability in real-life applications. To overcome those restrictions, we propose to combine acoustic emission and reinforcement learning. The former captures the information about the subsurface dynamics of the process. The latter is a branch of machine learning that allows interpreting the received data in terms of quality. The combination of both is an original method for in situ and real-time quality monitoring. Acoustic data were collected during a real process using a commercial AM machine. The process parameters were selected to achieve three levels of quality in terms of porosity concentration while manufacturing a stainless steel 316L cuboid shape. Using our method, we demonstrated that each level of quality produced unique acoustic signatures during the build that were recognized by the classifier. The classification accuracy reached in this work proves that the proposed method has high potential to be used as in situ and real-time monitoring of AM quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of on-line and near real-time spectroscopic monitoring of processes relevant to nuclear material management

Spectroscopic chemometric based on-line monitoring of used nuclear fuel (UNF) reprocessing solutions and characterization of legacy nuclear waste (LNW) stored at Hanford is discussed in this manuscript. Using on-line and near real-time monitoring with spectroscopy, as opposed to traditional off-line monitoring, can significantly reduce the cost, risk and improve the efficiency of characterizing UNF reprocessing streams and LNW since the data can be collected non-destructively and analyzed nearly instantly. It can accurately quantify and qualify nuclear material in near-real time which can help to know the immediate UNF reprocessing stream and LNW conditions and detect the diversion of materials. The ability to be applied in a real reprocessing plant and in an actual Hanford waste tank/transfer pipe has been demonstrated by applying this technique to accurately quantify analytes in real UNF streams and LNW samples. Furthermore, the future development of spectroscopy based on-line monitoring is also discussed in this manuscript.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Unmanned Aerial System (UAS) for concurrent measurements of solar-induced chlorophyll fluorescence and hyperspectral reflectance toward improving crop monitoring

Unmanned aerial system (UAS)-based remote sensing can provide high spatial- and temporal-resolution crop monitoring for precision management. Existing crop monitoring UAS primarily use conventional techniques such as multi-spectral broadband vegetation indices (VIs) to track canopy structure/biomass. Recently developed lightweight hyperspectral sensors can track crop physiology and performance via complementary signals such as solar-induced chlorophyll fluorescence (SIF) and photochemical reflectance index (PRI) that can be derived from hyperspectral reflectance. However, few existing UAS can acquire high-quality SIF and hyperspectral reflectance. Here, we designed a novel UAS that simultaneously captures far-red SIF and hyperspectral reflectance, using a single bifurcated fiber and motorized arm to measure downwelling and upwelling irradiance. The UAS was tested over (1) a heterogeneous corn field with spatially varying crop yield potential and (2) a set of soybean and corn plots under differing nutrient treatments. Our UAS can maintain stability under low-to-moderate winds (2–3 m/s) with <0.4 m geolocation accuracy, <0.1 m altitude drift, and <1.5° error of the fiber optic from nadir position during scanning. Weekly seasonal campaigns reveal that SIF outperforms conventional VIs such as the normalized difference vegetation index (NDVI) for distinguishing plots with different crop yield potential, especially after canopy closure when NDVI tends to saturate. The UAS can capture the diurnal dynamics of SIF and PRI for both corn and soybean. At the seasonal scale, SIF acquired from the UAS correlates well with that from a fixed SIF tower system ( R 2 = 0.81), which measured the same target albeit with different footprints, demonstrating the capability of UAS in characterizing the seasonal progression of crop activity. In conclusion, our newly developed UAS provides high-quality SIF and hyperspectral reflectance, facilitating mechanistic understanding of the physiological control on photosynthesis dynamics. Our findings also imply that this UAS could enable extension of fixed tower-based systems to monitor multiple targets from diurnal to seasonal scales and improve monitoring of heterogeneous fields.

59 BASIC BIOLOGICAL SCIENCES↗

Confronting barriers and recognizing opportunities: Developing effective community-based environmental monitoring programs to meet the needs of Aboriginal communities

Aboriginal communities can be negatively affected by resource development, but often they do not have a full opportunity to participate in project review and the resulting monitoring and mitigation activities. Cumulative impacts of resource development are also typically neglected in monitoring protocols that focus on a limited number of environmental values, rather than adopting a long-term, holistic view of development over time and space. Community-based environmental monitoring (CBEM) is emerging as a way to meaningfully include local Aboriginal citizens in the decision-making process as well as the assessment of the long-term impacts of the development of natural resources. We explored opportunities and barriers for developing CBEM programs that meet the needs of small and rural Aboriginal communities that are faced with the rapid and wide-spread development of natural resources. We conducted interviews with a local Aboriginal community, and natural resource management practitioners who could provide perspectives on the application of CBEM to resource management in north-central British Columbia, Canada. Results demonstrate that CBEM offers a locally adapted and culturally appropriate approach to facilitate the participation of Aboriginal communities in natural resource decision making and management. The interpretation of the specific role and purpose of CBEM differed among participants, depending on their objectives for and concerns about natural resource development. However, all parties were consistent in viewing CBEM as an effective method for engaging in dialogue, cooperation, and tracking environmental change. The development or improvement of CBEM programs should consider the efficacy of monitoring protocols, social cohesion and relationships, ability to inform decision-making, and effectiveness of CBEM for the members of the community. - Highlights: • We explored how to develop effective CBEM with a focus on Aboriginal communities. • We identified opportunities and barriers for developing CBEM programs. • CBEM can facilitate Aboriginal community participation in natural resource management.

54 ENVIRONMENTAL SCIENCES↗

Feasibility of FDEM cross-dipole and TDEM loop sources for monitoring CO 2 at the Kemper CarbonSAFE site

Electromagnetics has been shown to be a viable tool to monitor CO 2 plumes embedded in saline reservoirs. However, the majority of studies focus on measuring the electric field, which requires cumbersome equipment in the field and it is difficult to install permanent measurement stations. Magnetic field receivers offer an opportunity to reduce the form factor of the survey and increase the mobility by utilizing upcoming technologies, such as drones. We explore the use of frequency-domain electric dipole sources, and timedomain loops with a focus on measuring the secondary magnetic field at the surface for a conceptual injection scenario based on the Kemper CarbonSAFE site. We find that electric dipole sources give a response above the sensitivity of current sensor technology and, therefore, be a viable tool for CO 2 monitoring. The time domain loop source does provide fields that are useful for determining the location of the CO 2 plume, however the field magnitude is below the sensitivity of the current generation of instruments. To explore the use of a potential borehole receiver we generate a map of the magnetic field at depth to explore potential borehole placement for monitoring efforts. Finally, we limit the spatial extent of the electric dipole survey to a single parcel of land to help understand how the fields change with survey geometry. We find that the shape of the secondary fields change slightly with the small transmitter, but are still measurable provided that the cultural noise at the site is low. Thus, we conclude that at the Kemper site a frequency-domain cross-dipole source with magnetometer receivers is suitable to monitor the expansion of the CO 2 plume in the saline reservoir, even with a limited transmitter footprint on the surface.

58 GEOSCIENCES↗

Source Term Analysis of Xenon (STAX): An effort focused on differentiating man-made isotope production from nuclear explosions via stack monitoring

An overview of the hardware and software developed for the Source Term Analysis of Xenon (STAX) project is presented which includes the data collection from two stack monitoring systems installed at medical isotope production facilities, infrastructure to transfer data to a central repository, and methods for sharing data from the repository with users. STAX is an experiment to collect radioxenon emission data from industrial nuclear facilities with the goal of developing a better understanding of the global radioxenon background and the effect industrial radioxenon releases have on nuclear explosion monitoring. The final goal of this work is to utilize collected data along with atmospheric transport modeling to calculate the contribution of a peak or set of peaks detected by the International Monitoring System (IMS) to provide desired discriminating information to the International Data Centre (IDC) and National Data Centers (NDCs). Types of data received from the STAX equipment are shown and collected data was used for a case study to predict radioxenon concentrations at two IMS stations closest to the Institute for RadioElements (IRE) in Belgium. The initial evaluation of results indicate that the data is very valuable to the nuclear explosion monitoring community.

07 ISOTOPE AND RADIATION SOURCES↗

Characterizing precipitate evolution of an Al–Zn–Mg–Cu-based commercial alloy during artificial aging and non-isothermal heat treatments by in situ electrical resistivity monitoring

In situ electrical resistivity monitoring technique was employed to continuously evaluate the precipitate evolution of an Al–Zn–Mg–Cu-based commercial alloy during typical artificial aging treatments. The effects of artificial aging on the precipitates stability during non-isothermal heat treatments were also explored. Conventional hardness test, transmission electron microscopy and differential scanning calorimetry were also adopted to verify the electrical resistivity results. The results indicated that both the precipitation process and its timely rate could be followed by the monitored electrical resistivity during artificial aging treatments. The electrical resistivity results gave overall information on continuous precipitation and dissolution processes, especially under high heating rates. Samples artificial aging heat treated at 120 °C for 24 h followed by aging at 150 °C for 24 h presented more stable state and coarser precipitates than the samples only artificial aging heat treated at 120 °C for 24 h or triple artificial aging heat treated at 120 °C/24 h + 195 °C/15 min + 120 °/24 h. While the incoherent η precipitates in the samples artificial aging heat treated at 120 °C for 24 h followed by aging at 150 °C for 24 h were more easiness to coarsening and dissolve during non-isothermal heat treatments as well. - Highlights: • In situ electrical resistivity monitoring technique was employed on an Al-Zn-Mg-Cu alloy. • The precipitate evolution during typical artificial aging treatments was studied. • The precipitate stability during non-isothermal heat treatments was explored. • The electrical resistivity wonderfully monitored continuous precipitation and dissolution. • The alloy submitted to a T7 treatment presents a more stable state during heating due to incoherent η precipitates.

36 MATERIALS SCIENCE↗

Accuracy evaluation of the optical surface monitoring system on EDGE linear accelerator in a phantom study

Frameless stereotactic radiosurgery (SRS) requires dedicated systems to monitor the patient position during the treatment to avoid target underdosage due to involuntary shift. The optical surface monitoring system (OSMS) is here evaluated in a phantom-based study. The new EDGE linear accelerator from Varian (Varian, Palo Alto, CA) integrates, for cranial lesions, the common cone beam computed tomography (CBCT) and kV-MV portal images to the optical surface monitoring system (OSMS), a device able to detect real-time patient's face movements in all 6 couch axes (vertical, longitudinal, lateral, rotation along the vertical axis, pitch, and roll). We have evaluated the OSMS imaging capability in checking the phantoms' position and monitoring its motion. With this aim, a home-made cranial phantom was developed to evaluate the OSMS accuracy in 4 different experiments: (1) comparison with CBCT in isocenter location, (2) capability to recognize predefined shifts up to 2° or 3 cm, (3) evaluation at different couch angles, (4) ability to properly reconstruct the surface when the linac gantry visually block one of the cameras. The OSMS system showed, with a phantom, to be accurate for positioning in respect to the CBCT imaging system with differences of 0.6 ± 0.3 mm for linear vector displacement, with a maximum rotational inaccuracy of 0.3°. OSMS presented an accuracy of 0.3 mm for displacement up to 1 cm and 1°, and 0.5 mm for larger displacements. Different couch angles (45° and 90°) induced a mean vector uncertainty < 0.4 mm. Coverage of 1 camera produced an uncertainty < 0.5 mm. Translations and rotations of a phantom can be accurately detect with the optical surface detector system.

61 RADIATION PROTECTION AND DOSIMETRY↗

A collision timing monitor for SuperKEKB

The analysis of beamstrahlung radiation, emitted from a beam of charged particles due to the electromagnetic interaction with a second beam of charged particles, provides a diagnostic tool that can be used to monitor beam–beam collisions in a e + e - storage ring. In this paper we show that the beamstrahlung time profile is related to the timing of the collisions and the length of the beams, and how its measurement can be used to monitor and optimize collisions at the interaction point of the SuperKEKB collider. The method has a unique passive monitor capability, since it allows to monitor the timing of the collision without disturbing (scanning) the beam–beam timing, which needs to be measured to unprecedented accuracy at SuperKEKB. To measure the time dependence of beamstrahlung, here we describe a method based on nonlinear frequency mixing in a nonlinear crystal of beamstrahlung radiation with photons from a pulsed laser. We demonstrate that the method allows to measure and optimize the relative timing and length of the colliding bunches with 3% accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light monitoring system for the lead tungstate calorimeter in Hall D at Jefferson Lab

A new electromagnetic calorimeter composed of 1596 lead tungstate (PbWO 4 ) scintillating crystals has been constructed for the GlueX detector in Hall D at Jefferson Lab. The calorimeter is equipped with a light monitoring system that uses light-emitting diodes. The light monitoring system was fabricated, installed, and integrated into the GlueX trigger system. It was successfully operated during detector commissioning and data collection, providing monitoring of the detector response and verification of the calibration with a precision better than 1%. In conclusion, the paper describes the design, installation, and performance of the light monitoring system.

Lead tungstate calorimeter↗

Early detection and evaluation of waste through sensorized containers for a collection monitoring application

The present study describes a novel application for use in the monitoring of municipal solid waste, based on distributed sensor technology and geographical information systems. Original field testing and evaluation of the application were carried out in Pudong, Shanghai (PR China). The local waste management system in Pudong features particular requirements related to the rapidly increasing rate of waste production. In view of the fact that collected waste is currently deployed to landfills or to incineration plants within the context investigated, the key aspects to be taken into account in waste collection procedures include monitoring of the overall amount of waste produced, quantitative measurement of the waste present at each collection point and identification of classes of material present in the collected waste. The case study described herein focuses particularly on the above mentioned aspects, proposing the implementation of a network of sensorized waste containers linked to a data management system. Containers used were equipped with a set of sensors mounted onto standard waste bins. The design, implementation and validation procedures applied are subsequently described. The main aim to be achieved by data collection and evaluation was to provide for feasibility analysis of the final device. Data pertaining to the content of waste containers, sampled and processed by means of devices validated on two purpose-designed prototypes, were therefore uploaded to a central monitoring server using GPRS connection. The data monitoring and management modules are integrated into an existing application used by local municipal authorities. A field test campaign was performed in the Pudong area. The system was evaluated in terms of real data flow from the network nodes (containers) as well as in terms of optimization functions, such as collection vehicle routing and scheduling. The most important outcomes obtained were related to calculations of waste weight and volume. The latter data were subsequently used as parameters for the routing optimization of collection trucks and material density evaluation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long-Term Statistical Process Monitoring of an Ultrafiltration Water Treatment Process

As water treatment technology has improved, the amount of available process data has substantially increased, making real-time, data-driven fault detection a reality. One shortcoming of the fault detection literature is that methods are usually evaluated by comparing their performance on hand-picked, short-term case studies, which yields no insight into long-term performance. In this work, we first evaluate multiple statistical and machine learning approaches for detrending process data. Then, we evaluate the performance of a PCA-based fault detection approach, applied to the detrended data, to monitor influent water quality, filtrate quality, and membrane fouling of an ultrafiltration membrane system for indirect potable reuse. Based on two short case studies, the adaptive lasso detrending method is selected, and the performance of the multivariate approach is evaluated over more than a year. The method is tested for different sets of three critical tuning parameters, and we find that for long-term, autonomous monitoring to be successful, these parameters should be carefully evaluated. However, in comparison with industry standards of simpler, univariate monitoring or daily pressure decay tests, multivariate monitoring produces substantial benefits in long-term testing.

ammonia↗