Search NASA⌕ Search

SEARCH · Search NASA

Results for “Padding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Characterization of two types of polysaccharides from Eremurus hissaricus roots growing in Tajikistan

Eremurus Hissaricus (E.hissaricus) is a native plant of Tajikistan that has been used in traditional medicine and whose raw components have been identified as having potential for the domestic economy. We have found that carbohydrates comprise 80–85% of the root biomass, from which we have characterized two types of polysaccharides: A water-soluble polysaccharide (WSP) and an acid-soluble polysaccharide (ASP), with 23% and 8% yields, respectively. The results from FTIR, HPAEC-PAD, HPSEC, methylation linkage analysis and NMR spectroscopy ( 1 H, 13 C, zTOCSY, HSQC, HSQCTOXY and HMBC) demonstrated that WSP has a backbone of (1 → 4)-linked β-d-mannopyranosyl and β-d-glucopyranosyl residues in a 1.5:1 M ratio, having acetylated groups, with weight-average molecular weights of 495 kDa. Analyses of ASP indicate that it is comprised of d-galactose, d-mannose, and d-glucose in a molar ratio of 1.8: 1.6: 1.0, which is consistent with a branched galactoglucomannan polysaccharide with (1 → 4)-linked β-pyranose configurations, and weight-average molecular weight of 179 kDa. The FTIR absorption bands in the region of 875–890 cm 1 and NMR spectroscopy data confirm the presence of β-pyranose configuration of main polysaccharide backbone in the both ASP and WSP samples. These polysaccharides are an available raw material with the potential for use in a number of industrial applications.

59 BASIC BIOLOGICAL SCIENCES↗

Predicting the potential for mineral scale precipitation in unconventional reservoirs due to fluid-rock and fluid mixing geochemical reactions

Mineral precipitation within hydraulically fractured shale may affect fluid flow pathways and impact longterm hydrocarbon production. The ability to predict geochemical reactions that lead to problematic mineral precipitation will lead to active reservoir management strategies to improve overall production. Using the Marcellus Shale as a case study, a combination of laboratory experiments and reaction path modeling was applied to determine which reactions are likely to occur upon introduction of hydraulic fracturing fluid into the shale reservoir. Experimental results indicate that contact between fracturing fluid and shale will result in dissolution of primary minerals (quartz, feldspars, kaolinite, chlorite, pyrite) and secondary mineral precipitation over time periods of less than one week. Precipitation of barite, Fe-oxides, feldspars, amorphous silica and clay is likely to occur within the reservoir during shut in and early flowback due to mixing between fracturing fluid and reservoir brine as based on modeling saturation indices using experimental fluid data. Reaction path modeling of the experimental scenarios corroborates the specific dissolution and precipitation reactions observed experimentally. Comparison of the results to injected and produced waters from a Marcellus Shale well pad in Greene County, PA, USA, shows that the mineral reactions occur during the hydraulic fracturing, shut in, and early flowback periods. The results presented in this paper demonstrate the value in applying experimental approaches to identify mineral precipitation/dissolution reactions that may significantly impact reservoir performance. The good agreement between geochemical models and experimental results provides confidence that numerical models can be applied to screen the potential fluid-mineral and fluid-mixing reactions in unconventional reservoirs that result in undesired mineral scale precipitation.

58 GEOSCIENCES↗

Improved adhesion of polyurethane-based nanocomposite coatings to tin surface through silane coupling agents

Conformal coatings with higher adhesion strength is critical for mitigating the growth of whiskers from the pure tin (Sn) or Sn-rich surfaces of the Pb-free electronics. Silane coupling agents have the ability to form a durable bond between polymeric coatings and metallic materials. The main goal of this paper is to investigate the effect of silane agents on the adhesion behavior of polyurethane (PU), polyurethane acrylate (PUA) and both coatings filled with silicone rubber (SR) nanoparticles on the tin solder pads. It was found that an isocyanate-based silane provided excellent adhesion for PU and PU + SR coatings and an acrylic-based silane for PUA and PUA + SR coatings on the tin surface. This was due to the reaction bond formation between the silane coupling agent and the coating. Hence, the selection of silane coupling agents with the organofunctional group similar to the coating material is crucial to improve the adhesion properties of the coating.

36 MATERIALS SCIENCE↗

Late Side Effects and Quality of Life After Radiotherapy for Rectal Cancer

Purpose: There is little knowledge on long-term morbidity after radiotherapy (50 Gy) and total mesorectal excision for rectal cancer. Therefore, late effects on bowel, anorectal, and urinary function, and health-related quality of life (QoL), were studied in a national cohort (n = 535). Methods and Materials: All Norwegian patients who received pre- or postoperative (chemo-)radiotherapy for rectal cancer from 1993 to 2003 were identified. Patients treated with surgery alone served as controls. Patients were without recurrence or metastases. Bowel and urinary function was scored with the LENT SOMA scale and the St. Marks Score for fecal incontinence and QoL with the European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire (QLQ-C30). Results: Median time since surgery was 4.8 years. Radiation-treated (RT+) patients (n = 199) had increased bowel frequency compared with non-radiation-treated (RT-) patients (n = 336); 19% vs. 6% had more than eight daily bowel movements (p < 0.001). In patients without stoma, a higher proportion of RT+ (n = 69) compared with RT- patients (n = 240), were incontinent for liquid stools (49% vs. 15%, p < 0.001), needed a sanitary pad (52% vs. 13%, p < 0.001), and lacked the ability to defer defecation (44% vs. 16%, p < 0.001). Daily urinary incontinence occurred more frequently after radiotherapy (9% vs. 2%, p = 0.001). Radiation-treated patients had worse social function than RT- patients, and patients with fecal or urinary incontinence had impaired scores for global quality of life and social function (p < 0.001). Conclusions: Radiotherapy for rectal cancer is associated with considerable long-term effects on anorectal function, especially in terms of bowel frequency and fecal incontinence. RT+ patients have worse social function, and fecal incontinence has a negative impact on QoL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Survivin Is a Potential Mediator of Prostate Cancer Metastasis

Purpose: We examined whether Survivin expression is associated with an increased risk of metastasis in prostate cancer. Methods and Materials: A total of 205 patients with T1 (23%) and T2 (77%) prostate cancer were treated with conventional external beam radiation therapy from 1991 to 1993 at the Massachusetts General Hospital. Of the patients, 62 had adequate and suitable-stained tumor material for Survivin analysis. Median follow-up was 102 months (range, 5-127 months). Distant failure was determined on the basis of clinical criteria. In preclinical studies, replication-deficient adenovirus encoding phosphorylation-defective Survivin Thr34{yields}Ala dominant-negative mutant pAd-S(T34A) or short hairpin RNA (shRNA) was used to inhibit Survivin in prostate cancer models, and the cell motility, morphology, and metastasis were investigated. Results: Our correlative data on men with early-stage (T1/T2) prostate cancers treated at Massachusetts General Hospital by definitive radiotherapy indicated that overexpression of Survivin (positive staining in {>=}10% cells) was associated with a significantly increased risk for the subsequent development of distant metastasis (p = 0.016) in the univariate analysis. In the multivariate analysis, overexpression of Survivin remained an independent predictor of distant metastasis (p = 0.008). The inhibition of Survivin dramatically inhibited invasiveness of prostate cancer cells in the in vitro invasion assay and spontaneous metastasis in the Dunning prostate cancer in vivo model. Furthermore, attenuation of Survivin resulted in changes in the microtubule cytoskeleton, loss of cellular polarity, and loss of motility. Conclusions: This study suggests that Survivin may be a potentially important prognostic marker and promising therapeutic target in metastatic prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Impact of Endometrial Cancer Diagnosis and Treatment on Health-Related Quality of Life and Cancer Survivorship: Results From the Randomized PORTEC-2 Trial

Purpose: To evaluate the long-term health-related quality of life (HRQL) after external beam radiation therapy (EBRT) or vaginal brachytherapy (VBT) among PORTEC-2 trial patients, evaluate long-term bowel and bladder symptoms, and assess the impact of cancer on these endometrial cancer (EC) survivors. Patients and Methods: In the PORTEC-2 trial, 427 patients with stage I high–intermediate-risk EC were randomly allocated to EBRT or VBT. The 7- and 10-year HRQL questionnaires consisted of EORTC QLQ-C30; subscales for bowel and bladder symptoms; the Impact of Cancer Questionnaire; and 14 questions on comorbidities, walking aids, and incontinence pads. Analysis was done using linear mixed models for subscales and (ordinal) logistic regression with random effects for single items. A two-sided P value <.01 was considered statistically significant. Results: Longitudinal HRQL analysis showed persisting higher rates of bowel symptoms with EBRT, without significant differences in global health or any of the functioning scales. At 7 years, clinically relevant fecal leakage was reported by 10.6% in the EBRT group, versus 1.8% for VBT (P=.03), diarrhea by 8.4% versus 0.9% (P=.04), limitations due to bowel symptoms by 10.5% versus 1.8% (P=.001), and bowel urgency by 23.3% versus 6.6% (P<.001). Urinary urgency was reported by 39.3% of EBRT patients, 25.5% for VBT, P=.05. No difference in sexual activity was seen between treatment arms. Long-term impact of cancer scores was higher among the patients who had an EC recurrence or second cancer. Conclusions: More than 7 years after treatment, EBRT patients reported more bowel symptoms with impact on daily activities, and a trend for more urinary symptoms, without impact on overall quality of life or difference in cancer survivorship issues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ASCENDE-RT: An Analysis of Treatment-Related Morbidity for a Randomized Trial Comparing a Low-Dose-Rate Brachytherapy Boost with a Dose-Escalated External Beam Boost for High- and Intermediate-Risk Prostate Cancer

Purpose: To report the genitourinary (GU) and gastrointestinal (GI) morbidity and erectile dysfunction in a randomized trial comparing 2 methods of dose escalation for high- and intermediate-risk prostate cancer. Methods and Materials: ASCENDE-RT (Androgen Suppression Combined with Elective Nodal and Dose Escalated Radiation Therapy) enrolled 398 men, median age 68 years, who were then randomized to either a standard arm that included 12 months of androgen deprivation therapy and pelvic irradiation to 46 Gy followed by a dose-escalated external beam radiation therapy (DE-EBRT) boost to 78 Gy, or an experimental arm that substituted a low-dose-rate prostate brachytherapy (LDR-PB) boost. At clinic visits, investigators recorded GU and GI morbidity and information on urinary continence, catheter use, and erectile function. Exclusion of 15 who received nonprotocol treatment and correction of 14 crossover events left 195 men who actually received a DE-EBRT boost and 188, an LDR-PB boost. Median follow-up was 6.5 years. Results: The LDR-PB boost increased the risk of needing temporary catheterization and/or requiring incontinence pads. At 5 years the cumulative incidence of grade 3 GU events was 18.4% for LDR-PB, versus 5.2% for DE-EBRT (P<.001). Compared with the cumulative incidence, the 5-year prevalence of grade 3 GU morbidity was substantially lower for both arms (8.6% vs 2.2%, P=.058). The 5-year cumulative incidence of grade 3 GI events was 8.1% for LDR-PB, versus 3.2% for DE-EBRT (P=.124). The 5-year prevalence of grade 3 GI toxicity was lower than the cumulative incidence for both arms (1.0% vs 2.2%, respectively). Among men reporting adequate baseline erections, 45% of LDR-PB patients reported similar erectile function at 5 years, versus 37% after DE-EBRT (P=.30). Conclusions: The incidence of acute and late GU morbidity was higher after LDR-PB boost, and there was a nonsignificant trend for worse GI morbidity. No differences in the frequency of erectile dysfunction were observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Meso-scale microstructural agglomerate quantification in boron carbide using X-ray microcomputed tomography

Highlights: • First known quantification of agglomerate defect distributions comprising of carbonaceous and aluminum nitride phases B{sub 4}C. • In-depth statistical analyses of the size, orientation, and morphology of the defects. • The determination of directional dependence of the hot-pressing direction on the agglomerate distributions. - Abstract: Failure in brittle materials is governed, in part, by the specific microstructure of that material, with heterogeneous microstructures generally leading to reduced mechanical properties and performance. In ceramics used for armor, an increase in compressive strength can be an indicator of improved ballistic performance. In hot-pressed boron carbide (B{sub 4}C) ceramic plates, failure has been attributed to carbonaceous flakes observed on the fracture surfaces of failed specimens. However, this current work shows agglomerates, in addition to the carbonaceous flakes, are present in this boron carbide. The density and distribution of these agglomerates are believed to influence the ballistic performance. Therefore, it is of interest to improve the quantification of meso-scale microstructural agglomerates so that strategies can be developed to mitigate them. This work is focused on the microstructural characterization of dumbbell-shaped compression specimens that were machined from a single tile of pressure-aided densification (PAD) B{sub 4}C, using high-resolution micro-computed tomography (microCT). Large clusters of non-B{sub 4}C agglomerates, up to 125 μm in diameter, were observed in addition to the typical smaller carbonaceous flakes and aluminum-based phases. Agglomerate size distribution, orientation, morphology, and spacing were quantified both parallel and perpendicular to the pressing direction. This defect quantification provides valuable information for a better understanding of the material microstructure which is a critical step in improving armor materials for the future.

36 MATERIALS SCIENCE↗

Enhancement of photocatalytic properties of Bi{sub 2}WO{sub 6} nanoparticles by Pt deposition

Graphical abstract: - Highlights: • Pt/Bi{sub 2}WO{sub 6} was used for photocatalytic degradation of methyl orange dye. • Photocatalytic degradation was dependent on wt% of Pt reaction time, and weight of catalyst. • Kinetic study revealed that the photocatalytic degradation of methyl orange dye followed the first order. • Catalyst re-use revealed the present photocatalyst remain effective and active after five cycles. - Abstract: Bi{sub 2}WO{sub 6} nanoparticles were prepared using a hydrothermal method, and Pt was immobilized on the surface of Bi{sub 2}WO{sub 6} via a photo-assisted deposition (PAD) method. The samples produced were characterized using X-ray diffraction, ultraviolet and visible spectroscopy, photoluminescence emission spectra, transmission electron microscopy, extended X-ray absorption fine structure, and surface area measurements. Furthermore, the catalytic performance of the Bi{sub 2}WO{sub 6} and Pt/Bi{sub 2}WO{sub 6} samples was examined in the degradation of methyl orange dye (MO) under visible light. The extended X-ray absorption fine structure (EXAFS) results, which showed the presence of peaks assigned to the Pt–Pt at approximately 2.50 Å, indicate the formation of nanoscale Pt features. The UV–vis spectral analysis detected a red shift after loading the Pt into the Bi{sub 2}WO{sub 6}. The maximum degradation efficiency achieved was 100% with 0.3 Pt/Bi{sub 2}WO{sub 6} as the photocatalyst after a 30-min reaction time. The catalyst could be reused without any loss in activity for the first five cycles.

36 MATERIALS SCIENCE↗

Enhanced light extraction efficiency of GaN-based light-emittng diodes by nitrogen implanted current blocking layer

Highlights: • A nitrogen implanted current-blocking layer was successfully demonstrated. • Light-extraction efficiency and radiant intensity was increased by more than 20%. • Ion implantation was successfully implemented in GaN based light-emitting diodes. - Abstract: GaN-based light emitting diodes (LEDs) with a nitrogen implanted current-blocking layer (CBL) were successfully demonstrated for improving the light extraction efficiency (LEE) and radiant intensity. The LEE and radiant intensity of the LEDs with a shallow implanted CBL with nitrogen was greatly increased by more than 20% compared to that of a conventional LED without the CBL due to an increase in the effective current path, which reduces light absorption at the thick p-pad electrode. Meanwhile, deep implanted CBL with a nitrogen resulted in deterioration of the LEE and radiant intensity because of formation of crystal damage, followed by absorption of the light generated at the multi-quantum well(MQW). These results clearly suggest that ion implantation method, which is widely applied in the fabrication of Si based devices, can be successfully implemented in the fabrication of GaN based LEDs by optimization of implanted depth.

36 MATERIALS SCIENCE↗

Upgrade of the proximity focusing RICH at Jlab

The Hall A RICH at Jefferson Lab is undergoing an upgrade to adapt to the higher momentum kinematics of the neutron spin structure Transversity experiments planned to run in 2008. The JLab RICH is a proximity focusing detector using liquid C6F14 as Cherenkov radiator, a thin layer of CsI as photon converter, evaporated on segmented pad panels of a proportional chamber. The original RICH had a superior hadron identification up to 2 GeV/c with pion/kaon rejection at the level of 1:1000 at ~ similar90% intrinsic efficiency. The upgrade will extend this performance above 2.4 GeV/c by means of a larger photon detector (a multiwire-multipad proportional chamber) and a longer proximity gap which will improve the photon detection geometrical efficiency and the angular resolution, respectively.

43 PARTICLE ACCELERATORS↗

3D Simulations of Irradiated One-Sided Dual-Column 3D Silicon Detector

We undertook, at Brookhaven National Laboratory (BNL), full 3D simulations of one-sided dual-type column 3D Si detectors (p-type substrate) after irradiation levels up to 1 x 10{sup 16} n{sub eq}/cm{sup 2}. Etching does not extend all the way through the substrate, so that all electrodes are on the front side; the backside was neither supported nor processed, covered only with a layer of silicon dioxide. Hence, BNL's one-sided dual-type column 3D detectors are true one-sided detectors. Our simulations of the electric fields at various fluences will add to our knowledge about the practicable applicability of these detectors in the high-radiation environment of future colliders. Simulations show that the full depletion voltage, V{sub fd}, for a dual-column 3D detector is about 1.4 times higher than that of a 2D (planar) pad detector with a thickness d, the same as the column spacing, L{sub p}, in the 3D detector. Moreover, the highest E-field is near the n{sup +} column, while the high E-field mainly is distributed between the n{sup +} and p{sup +} columns. The low E-field is between the two p{sup +} columns, with its lowest point in the center of the unit cell with two p{sup +} columns and two n{sup +} columns. To fully deplete a dual-column 3D detector at 1 x 10{sup 16} n{sub eq}/cm{sup 2} with a reasonable bias ({le} 200 V) necessitates reducing the column spacing, L{sub p}, to 30 {mu}m. The volume under the columns (10% of the total volume) can be depleted with a modest bias ({le}200 V); this underlying volume is not a dead volume. In addition, this depletion volume can support detection sensitivity directly under the columns, thereby lowering the effective dead volume in a 3D Si detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, construction, operation and performance of a Hadron Blind Detector for the PHENIX experiment

A Hadron Blind Detector (HBD) has been developed, constructed and successfully operated within the PHENIX detector at RHIC. The HBD is a Cherenkov detector operated with pure CF{sub 4}. It has a 50 cm long radiator directly coupled in a windowless configuration to a readout element consisting of a triple GEM stack, with a CsI photocathode evaporated on the top surface of the top GEM and pad readout at the bottom of the stack. This paper gives a comprehensive account of the construction, operation and in-beam performance of the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Test beam studies of silicon timing for use in calorimetry

The high luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN is expected to provide instantaneous luminosities of 5 X 10 34 cm –2 s –1 . The high luminosities expected at the HL-LHC will be accompanied by a factor of 5 to 10 more pileup compared with LHC conditions in 2015, causing general confusion for particle identification and event reconstruction. Precision timing allows to extend calorimetric measurements into such a high density environment by subtracting the energy deposits from pileup interactions. Calorimeters employing silicon as the active component have recently become a popular choice for the HL-LHC and future collider experiments which face very high radiation environments. In this article, we present studies of basic calorimetric and precision timing measurements using a prototype composed of tungsten absorber and silicon sensor as the active medium. Lastly, we show that for the bulk of electromagnetic showers induced by electrons in the range of 20 GeV to 30 GeV, we can achieve time resolutions better than 25 ps per single pad sensor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of uniformity of 50 μ m low-gain avalanche detectors at the Fermilab test beam

In this study, we report measurements of the uniformity of time resolution, signal amplitude, and charged particle detection efficiency across the sensor surface of low-gain avalanche detectors (LGAD). Comparisons of the performance of sensors with different doping concentrations and different active thicknesses are presented, as well as their temperature dependence and radiation tolerance up to 6 x 10 14 n/cm 2 . Results were obtained at the Fermilab test beam facility using 120 GeV proton beams, and a high precision pixel tracking detector. LGAD sensors manufactured by the Centro Nacional de Microelectrónica (CNM) and Hamamatsu Photonics (HPK) were studied. The uniformity of the sensor response in pulse height before irradiation was found to have a 2% spread. The signal detection efficiency and timing resolution in the sensitive areas before irradiation were found to be 100% and 30–40 ps, respectively. A “no-response” area between pads was measured to be about 130 μm for CNM and 170μm for HPK sensors. After a neutron fluence of 6 x 10 14 n/cm 2 the CNM sensor exhibits a large gain variation of up to a factor of 2.5 when comparing metalized and non-metalized sensor areas. An irradiated CNM sensor achieved a time resolution of 30 ps for the metalized area and 40 ps for the non-metalized area, while a HPK sensor irradiated to the same fluence achieved a 30 ps time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the Generic Electronics for Time Projection Chamber ($\mathrm{GET}$) readout system for heavy Radioactive isotope collision experiments

Here we have implemented the Generic Electronics for Time Projection Chamber (GET) in a SAMURAI Pion Reconstruction and Ion-Tracker (SπRIT) readout system for heavy radioactive ion collision experiments at RIKEN-RIBF. The SπRIT experiment is designed for heavy ion collision experiments with radioactive ion beams, where a Time Projection Chamber (TPC) with 12096 pixelized readout pads is employed as the main device. Since the TPC is located on the beam line, the readout electronics must handle small signals from pions as well as very large signals from beam or large fragment particles. Operation of the GET electronics during experiment functioned well using 270 time-bucket readout with 25 MHz sampling at an event Data acquisition (DAQ) rate of 60 Hz. Using the slope information of acquired signals it is possible to extend the dynamic range of dE/dx information compared to using the peak height information. However, huge signals arising from energetic δ-rays produced by un-interacted projectiles induce dead channels, which can be recovered after 70 μs on average.

47 OTHER INSTRUMENTATION↗