Energy Resource Center: Chart a Path to Continuous Energy Improvement (Postcard)
Postcard handout created for the Advanced Manufacturing Office to be used at meetings, presentations, and exhibits.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Postcard handout created for the Advanced Manufacturing Office to be used at meetings, presentations, and exhibits.
After over two decades of staggering economic growth and soaring energy demand, China has started taking serious actions to reduce its economic energy and carbon intensity by setting short and medium-term intensity reduction targets, renewable generation targets and various supporting policies and programs. In better understanding how further policies and actions can be taken to shape China's future energy and emissions trajectory, it is important to first identify where the largest opportunities for efficiency gains and emission reduction lie from sectoral and end-use perspectives. Besides contextualizing China's progress towards reaching the highest possible efficiency levels through the adoption of the most advanced technologies from a bottom-up perspective, the actual economic costs and benefits of adopting efficiency measures are also assessed in this study. This study presents two modeling methodologies that evaluate both the technical and economic potential of raising China's efficiency levels to the technical maximum across sectors and the subsequent carbon and energy emission implications through 2030. The technical savings potential by efficiency measure and remaining gap for improvements are identified by comparing a reference scenario in which China continues the current pace of with a Max Tech scenario in which the highest technically feasible efficiencies and advanced technologies are adopted irrespective of costs. In addition, from an economic perspective, a cost analysis of selected measures in the key industries of cement and iron and steel help quantify the actual costs and benefits of achieving the highest efficiency levels through the development of cost of conserved energy curves for the sectors. The results of this study show that total annual energy savings potential of over one billion tonne of coal equivalent exists beyond the expected reference pathway under Max Tech pathway in 2030. CO 2 emissions will also peak earlier under Max Tech, though the 2020s is a likely turning point for both emission trajectories. Both emission pathways must meet all announced and planned policies, targets and non-fossil generation targets, or an even wider efficiency gap will exist. The savings potential under Max Tech varies by sector, but the industrial sector appears to hold the largest energy savings and emission reduction potential. The primary source of savings is from electricity rather than fuel, and electricity savings are magnified by power sector decarbonization through increasing renewable generation and coal generation efficiency improvement. In order to achieve the maximum energy savings and emission reduction potential, efficiency improvements and technology switching must be undertaken across demand sectors as well as in the growing power sector. From an economic perspective, the cost of conserved energy analysis indicates that nearly all measures for the iron and steel and cement industry are cost-effective. All 23 efficiency measures analyzed for the cement industry are cost-effective, with combined CO 2 emission reduction potential of 448 Mt CO 2 . All of the electricity savings measures in the iron and steel industry are cost-effective, but the cost-effective savings potential for fuel savings measures is slightly lower than total technical savings potential. The total potential savings from these measures confirm the magnitude of savings in the scenario models, and illustrate the remaining efficiency gap in the cement and iron and steel industries.
Innovative strategy to reduce installed cost of solar water heater systems can rival conventional natural gas water heaters in the marketplace.
In this project, we cast distributed resource access as operations on files in a global name space and developed a common, scalable solution for group operations on distributed processes and files. The resulting solution enables tool and middleware developers to quickly create new scalable software or easily improve the scalability of existing software. The cornerstone of the project was the design of a new programming idiom called group file operations that eliminates iterative behavior when a single process must apply the same set of file operations to a group of related files. To demonstrate our novel and scalable ideas for group file operations and global name space composition, we developed a group file system called TBON-FS that leverages a tree-based overlay network (TBON), specifically MRNet, for logarithmic communication and distributed data aggregation. We also developed proc++, a new synthetic file system co-designed for use in scalable group file operations. Over the course of the project, we evaluated the utility and performance of group file operations, global name space composition, TBON-FS, and proc++ in three case studies. The first study focused on the ease in using group file operations and TBON-FS to quickly develop several new scalable tools for distributed system administration and monitoring. The second study evaluated the integration of group file operation and TBON-FS within the Ganglia Distributed Monitoring System to improve its scalability for clusters. The final study involved the integration of group file operations, TBON-FS, and proc++ within TotalView, the widely-used parallel debugger. For this project, the work of the Oak Ridge National Laboratory (ORNL) team occurred primarily in two directions: bringing the MRNet tree-based overlay network (TBON) implementation to the Cray XT platform, and investigating techniques for predicting the performance of MRNet topologies on such systems. Rogue Wave Software (RWS), formerly TotalView Technologies Inc., worked with the University ofWisconsin (UW) team on the design and prototyping of a scalable version of the TotalView debugger. RWS assisted UW with their "proc++" design effort. RWS assisted UW with strategy for integrating proc++ into TotalView.
Abstract not provided.
The U.S. Department of Energy (DOE) Office of Legacy Management developed this report as a guide for discussions with the Colorado State regulators and other interested stakeholders in response to increased drilling for natural gas reserves near the underground nuclear explosion site at Rulison, Colorado. The Rulison site is located in the Piceance Basin of western Colorado, 40 miles northeast of Grand Junction. The Rulison test was the second natural gas reservoir stimulation experiment in the Plowshare Program, which was designed to develop peaceful uses for nuclear energy. On September 10, 1969, the U.S. Atomic Energy Commission, a predecessor agency of DOE, detonated a 40-kiloton nuclear device 8426 feet below the ground surface in an attempt to release commercially marketable quantities of natural gas. The blast vaporized surrounding rock and formed a cavity about 150 feet in diameter. Although the contaminated materials from drilling operations were subsequently removed from the surface of the blast site, no feasible technology exists to remove subsurface radioactive contamination in or around the test cavity. An increase in drilling for natural gas near the site has raised concern about the possibility of encountering residual radioactivity from the area of the detonation. DOE prohibits drilling in the 40-acre lot surrounding the blast site at a depth below 6000 feet. DOE has no evidence that indicates contamination from the Rulison site detonation has migrated or will ever migrate beyond the 40-acre institutional control boundary. The Colorado Oil and Gas Conservation Commission (COGCC) established two wider boundaries around the site. When a company applies for a permit to drill within a 3-mile radius of surface ground zero, COGCC notifies DOE and provides an opportunity to comment on the application. COGCC also established a half-mile radius around surface ground zero. An application to drill within one-half mile requires a full hearing before the commission. This report outlines DOE's recommendation that gas developers adopt a conservative, staged drilling approach allowing gas reserves near the Rulison site to be recovered in a manner that minimizes the likelihood of encountering contamination. This staged approach calls for collecting data from wells outside the half-mile zone before drilling closer, and then drilling within the half-mile zone in a sequential manner, first at low contamination probability locations and then moving inward. DOE's recommended approach for drilling in this area will protect public safety while allowing collection of additional data to confirm that contamination is contained within the 40-acre institutional control boundary.
A 1.2×1.2 m 2 muon tracker was moved from Los Alamos to the Toshiba facility at Kawasaki, Japan where it was used to take ~4 weeks of data radiographing the Toshiba Critical Assembly Reactor with cosmic ray muons. In this paper we describe the analysis procedure, show results of this experiment and compare the results to Monte Carlo predictions. The results validate the concept of using cosmic rays to image the damaged cores of the Fukushima Daiichi reactors.
The Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) sponsored a workshop on non-Newtonian multiphase slurry at NETL’s Morgantown campus August 19 and 20, 2013. The objective of this special two-day meeting of 20-30 invited experts from industry, National Labs and academia was to identify and address technical issues associated with handling non-Newtonian multiphase slurries across various facilities managed by DOE. Particular emphasis during this workshop was placed on applications managed by the Office of Environmental Management (EM). The workshop was preceded by two webinars wherein personnel from ORP and NETL provided background information on the Hanford WTP project and discussed the critical design challenges facing this project. In non-Newtonian fluids, viscosity is not constant and exhibits a complex dependence on applied shear stress or deformation. Many applications under EM’s tank farm mission involve non-Newtonian slurries that are multiphase in nature; tank farm storage and handling, slurry transport, and mixing all involve multiphase flow dynamics, which require an improved understanding of the mechanisms responsible for rheological changes in non-Newtonian multiphase slurries (NNMS). To discuss the issues in predicting the behavior of NNMS, the workshop focused on two topic areas: (1) State-of-the-art in non-Newtonian Multiphase Slurry Flow, and (2) Scaling up with Confidence and Ensuring Safe and Reliable Long-Term Operation.
This presentation provides a system approach that evaluates each element of the PPS and how it contributes to overall system effectiveness; provides an elemental contribution that helps define performance requirements; provides a qualitative and quantitative aspect to PPS performance; and by way of a tool, allows analysts to combine and evaluate qualitative, quantitative data.
This analysis provides a limited evaluation of the relationship between the Residential Energy Services Network (RESNET) Home Energy Rating System (HERS) Index and the simulation-based performance approach used in the 2012 International Energy Conservation Code (IECC). Not all differences between the approaches are analyzed here; only a subset of the distinctions considered likely to result in quantifiable differences in the outcomes of the two approaches or otherwise believed to be of interest to code developers and policy makers are considered. This analysis evaluates, for a single-family residence with various characteristics, the ranges of HERS Index values that would result in compliance with the 2012 IECC.
This document guides you through a process for the early design phases of retrofit projects to help you mitigate frustrations commonly experienced by building owners and designers. It outlines the value of forming an integrated project delivery team and developing a communication and information-sharing infrastructure that fosters collaboration. This guide does not present a complete process for designing an energy retrofit for a building. Instead, it focuses on the early design phase tasks related to developing and selecting energy efficiency measures (EEMs) that benefit from collaboration, and highlights the resulting advantages.
The TTP program is managed by DHS S&T Cyber Division and facilitates the transition of technology from the research lab to the Homeland Security Enterprise. It serves as a connection point for cyber security researchers, the Federal Government, and the private sector. Technologies targeted are those that are likely to transition successfully to the commercial market and expected to have notable impact on the cyber security of our Nation’s networks or systems. The test element of the TTP program aids in the technology transfer process and is not intended to be adversarial. Additional information on the TTP program and the iterative process used can be found in Appendix A - TTP Program Overview.
Energy efficiency has been a federal procurement policy objective since at least 1992, with the origin of the Energy Efficient Product Procurement (EEPP) program within the larger Federal Energy Management Program (FEMP). Today, the EEPP program’s mandate is based on requirements that 95% of new contract actions, task orders, and delivery orders for products and services be energy and water efficient, as laid out in Executive Order 13514 in 2009. Facilitating full compliance with EO 13514 presents a significant strategic planning challenge to the FEMP EEPP program, given the size of the federal government, the range of missions of its many agencies, the mix of management approaches for its buildings, and the diverse set of roughly 80 energy efficient products which has been established through preceding legislation and executive orders. The goal of this report is to aid the program in prioritizing its resources by providing an overview of how the purchase of energy-consuming products occurs in today’s evolving federal procurement system, as well as identify likely intervention points and compliance review mechanisms. Through a synthesis of the literature on U.S. federal sector procurement and two dozen primary interviews, the report particularly focuses on the importance of price in determining the actor(s) responsible for any given purchase of an energy-consuming product. This identification is important, as the relevant actors are trained and reviewed in different ways that the FEMP EEPP program can prioritize for targeting, based on the decision criteria such as the potential energy savings associated with the actor’s purchases or the administrative ease of the intervention.
The Zimitar one-piece rotor primary structure is integrated, so balanced thrust and gravity loads flow through the hub region without transferring out of its composite material. Large inner rotor geometry is used since there is no need to neck down to a blade root region and pitch bearing. Rotor control is provided by a highly redundant, five flap system on each blade, sized so that easily handled standard electric linear actuators are sufficient.
KDEs show potential reducing variance for global solutions (flux, reaction rates) when compared to histogram solutions.
This report documents the energy-saving potential of toplighting, a form of daylighting that combines skylights and electric lighting controls.
To assess the resources needed to field a quantitative measurement to advance our knowledge on shape evolution, we have carried out a numerical simulation of the Coulomb excitation for 112 Ru at 460 MeV bombarding energy on a 208 Pb target of 1 mg/cm 2 using a semiclassical code, GOSIA with GRETINA/CHICO2.