Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Modeling Single and Two-Phase Transport in Thin Porous Layers Using a Composite Continuum-Pore Network Formulation

In this work, a composite continuum-pore network formulation is presented to model single and two-phase transport thin porous layers, such as gas diffusion layers in polymer electrolyte fuel cells (PEFCs) and active electrodes in redox flow batteries (RFBs). The formulation can be integrated into CFD codes, thus combining the ease of implementation of continuum-based modeling and the computational power of pore-network modeling. The composite model includes a control volume (CV) mesh at the layer scale, which embeds a cubic pore network [1,2]. The pore-network model is used to determine analytically local anisotropic effective transport properties (local effective diffusivity and permeability), which are mapped onto the CV mesh to simulate transport in the porous transport layer [3,4]. Good agreement is found between the predicted global effective transport properties (global effective diffusivity and permeability) under dry and wet conditions and previous experimental data reported in the literature for Toray TGP-H series carbon paper. Water saturation distributions are also compared with results obtained using X-ray computed tomography [4]. [1] P.A. García-Salaberri, I.V. Zenyuk, J.T. Gostick, A.Z. Weber, Modeling Gas Diffusion Layer in Polymer Electrolyte Fuel Cells Using a Continuum-Based Pore-Network Formulation, ECS Trans. 97 (2020) 615. [2] P.A. García-Salaberri, Modeling diffusion and convection in thin porous transport layers using a composite continuum-network model: Application to gas diffusion layers in polymer electrolyte fuel cells, Int J. Heat Mass Transf. (2020), submitted. [3] P.A. García-Salaberri, J.T. Gostick, G. Hwang, A.Z. Weber, M. Vera, Effective diffusivity in partially-saturated carbon-fiber gas diffusion layers: Effect of local saturation and application to macroscopic continuum models, J. Power Sources 296 (2015) 440–453. [4] P.A. García-Salaberri, G. Hwang, M. Vera, A.Z. Weber, J.T. Gostick, Effective diffusivity in partially-saturated carbon-fiber gas diffusion layers: Effect of through-plane saturation distribution, Int. J. Heat Mass Transf. 86 (2015) 319–333.

Garcia-Salaberri, Pablo↗

Modular Hybrid Solid State Transformer (H-SST) for Next Generation Flexible and Adaptable Large Power Transformer (LPT) (Final Technical Report)

A 500 kVA HSST, the world first of such system, has been successfully developed. The HSST has the capability to regulate the power flow of the transmission or distribution power lines, or provide voltage regulation. The HSST design is modular therefore it has the ability to be connected in series of parallel to form a large power transformer with smart controllability. The project has enabled a high TRL level prototype be demonstrated at University of Texas at Austin which can lead to additional commercialization and demonstration opportunities. A large number of students were trained under this program that will benefit the power grid industry. A number of publications are published at well known international conferences and journals, further accomplish the mission of knowledge development and dissemination.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of exothermic processes in shock ignited gases by the use of laser shear interferometry.

The paper reports on the measurements of maximum exothermic power pulses attainable from a given chemical system. Experimental tests involved the use of a shock tube technique whereby the exothermic process of combustion was controlled by reflected shock so that it occurred under virtually inviscid flow conditions, the data having been obtained at a resolution commensurate with the actual rate of chemical reaction. Experimental observations were made by means of a novel method of laser shear interferometry. Chemical systems treated in this manner comprised of mixtures of stoichiometric hydrogen-oxygen with 80 and 90% argon, while the measurements covered the full permissible range of initial thermodynamic conditions.

Meyer, J. W.↗

Study of exothermic processes in shock ignited gases by the use of laser shear interferometry

Report on measurements of maximum exothermic power pulses attainable from a given chemical system. Experimental tests involved the use of a shock tube technique whereby the exothermic process of combustion was controlled by reflected shock, so that it occurred under virtually inviscid flow conditions, while the measurements were performed at a resolution commensurate with the actual rate of chemical reaction. Experimental observations were made by means of a novel method of laser shear interferometry - a cross-breed between holography and the conventional means for measuring refractive index fields, in that, on one hand, it was based on the exploitation of the phase coherence of the laser light beam, recording first a diffraction image of the wave fronts which, for the desired final result, had to be optically reconstructed, and, on the other, it yielded eventually either two-dimensional interferograms or schlieren photographs of the observed phenomena.

Meyer, J. W.↗

Operating characteristics of 120-millimeter-bore ball bearings at 3 million DN

A parametric study was performed with split inner-race 120-mm-bore angular-contact ball bearings at a speed of 25,000 rpm (3 million DN) at initial contact angles of 20 deg and 24 deg. Provisions were made for outer- and inner-race cooling and for injection of lubricant into the bearing through a number of radial holes in the split inner-race of the bearing. Oil flow and coolant rate to the bearing was controlled and varied for a total up to approximately 3.2 gal/min. Bearing temperature was found to decrease as the total lubricant flow to the bearing increased. However, at intermediate flow rates temperature began to increase with increasing flow. Power consumption increased with increasing flow rate. Bearing operating temperature, differences in temperatures between the inner and outer races, and bearing power consumption can be tuned to any desirable operating requirement. Cage speed increased by not more than 2 percent with increasing oil flow to the inner race.

Zaretsky, E. V.↗

High power gas laser - Applications and future developments

Fast flow can be used to create the population inversion required for lasing action, or can be used to improve laser operation, for example by the removal of waste heat. It is pointed out that at the present time all lasers which are capable of continuous high-average power employ flow as an indispensable aspect of operation. High power laser systems are discussed, taking into account the gasdynamic laser, the HF supersonic diffusion laser, and electric discharge lasers. Aerodynamics and high power lasers are considered, giving attention to flow effects in high-power gas lasers, aerodynamic windows and beam manipulation, and the Venus machine. Applications of high-power laser technology reported are related to laser material working, the employment of the laser in controlled fusion machines, laser isotope separation and photochemistry, and laser power transmission.

Hertzberg, A.↗

Hyperfiltration wash water recovery subsystem - Design and test results

The Hyperfiltration Wash Water Recovery (HWWR) subsystem, designed to offer low-power high-volume wash water purification for extended mission spacecraft, is discussed in terms of preprototype design and configuration. Heated wash water collected from the shower, hand wash, and laundry flows into a temperature-controlled (374 K) waste storage tank. Two parallel 25 micron absolute filters at the tank outlet remove large particles from the feed stream. A positive displacement feed pump delivers wash water to the hyperfiltration module at a constant flow rate of 0.20 lpm with discharge pressure variations from 4181-7239 Kpa. The hyperfiltration membrane module is a single-pass design including 36 porous stainless steel tubes, and is designed to provide an approximate water recovery rate of 90 percent. Permeate and brine water flows are monitored by flow meters, and removal of urea and ammonia is achieved by adding 15 percent NaOCl solution to the permeate fluid stream. An alternate module design using two diameters of tubing (allowing a smaller pressure drop and a larger membrane area) gave a superior predicted performance over the first module with larger tubing throughout.

Reysa, R. P.↗

Aerodynamic design trends for commercial aircraft

Recent research on advanced-configuration commercial aircraft at DFVLR is surveyed, with a focus on aerodynamic approaches to improved performance. Topics examined include transonic wings with variable camber or shock/boundary-layer control, wings with reduced friction drag or laminarized flow, prop-fan propulsion, and unusual configurations or wing profiles. Drawings, diagrams, and graphs of predicted performance are provided, and the need for extensive development efforts using powerful computer facilities, high-speed and low-speed wind tunnels, and flight tests of models (mounted on specially designed carrier aircraft) is indicated.

Hilbig, R.↗

A dynamical model of lithosphere extension and sedimentary basin formation

The effect of convection-induced stresses at the base of the continental lithosphere on surface and extensional deviatoric stresses is investigated. The biaxial strain in the continental lithosphere is controlled by power law creep in the upper and lower crust, brittle failure, and the Dorn plasticity law. The relationship between the lithosphere stress distribution and Moho temperatures is examined. The extension factors, basin subsidence, heat flow, and sediment loading of the lithosphere are studied.

Houseman, G.↗

Simulation evaluation of transition and hover flying qualities of a mixed-flow, remote-lift STOVL aircraft

Using a generalized simulation model developed for piloted evaluations of STOVL aircraft, an initial fixed-base simulation of a mixed-flow, remote-lift configuration has been completed. Objectives were to evaluate the integration of the aircraft's flight and propulsion controls to achieve good flying qualities throughout the low-speed flight envelope; to determine control power used during transition, hover, and vertical landing; and to evaluate the transition flight envelope considering the influence of thrust deflection of the remote-lift component. Pilots' evaluations indicated that Level 1 flying qualities could be achieved for deceleration to hover in instrument conditions, for airfield landings, and for recovery to a small ship when attitude and velocity stabilization and command augmentation control modes were provided. Level 2 flying qualities were obtained for these same tasks when only the attitude command mode was used, leaving the pilot to perform the task of thrust management required to control the flight-path and speed in transition and the horizontal and vertical translational velocities in hover. Thrust margins were defined for vertical landing as a function of ground effect and hot-gas ingestion.

Franklin, James A.↗

Active Thermal Isolation For Hot-Film Anemometers

Local heating compensates for conduction of heat from sensors into modules. Two hot-film sensors stacked on wind-tunnel model. Outer sensor detects changes in boundary-layer flow. Inner sensor provides active thermal isolation between outer sensor and model. Thermal boundary condition controlled at response time of detection hot-film sensor, significantly less than response time of internally heated model. Requires less power to maintain outer hot-film sensor at given temperature, enabling system to respond over greater dynamic range before power limits of instrument reached. Stacked sensors bonded to surface of most wind-tunnel models, even to curved surfaces, and removed after completion of experiments.

Martinson, Scott D.↗

Specification and testing for power by wire aircraft

A power by wire aircraft is one in which all active functions other than propulsion are implemented electrically. Other nomenclature are 'all electric airplane,' or 'more electric airplane.' What is involved is the task of developing and certifying electrical equipment to replace existing hydraulics and pneumatics. When such functions, however, are primary flight controls which are implemented electrically, new requirements are imposed that were not anticipated by existing power system designs. Standards of particular impact are the requirements of ultra-high reliability, high peak transient bi-directional power flow, and immunity to electromagnetic interference and lightning. Not only must the electromagnetic immunity of the total system be verifiable, but box level tests and meaningful system models must be established to allow system evaluation. This paper discusses some of the problems, the system modifications involved, and early results in establishing wiring harness and interface susceptibility requirements.

Hansen, Irving G.↗

Status of Propulsion Technology Development Under the NASA In-space Propulsion Technology Program

Since 2001, the In-Space Propulsion Technology (ISPT) program has been developing and delivering in-space propulsion technologies for NASA's Science Mission Directorate (SMD). These in-space propulsion technologies are applicable, and potentially enabling for future NASA Discovery, New Frontiers, Flagship and sample return missions currently under consideration. The ISPT program is currently developing technology in three areas that include Propulsion System Technologies, Entry Vehicle Technologies, and Systems Mission Analysis. ISPT's propulsion technologies include: 1) the 0.6-7 kW NASA's Evolutionary Xenon Thruster (NEXT) gridded ion propulsion system; 2) a 0.3-3.9kW Hall-effect electric propulsion (HEP) system for low cost and sample return missions; 3) the Xenon Flow Control Module (XFCM); 4) ultra-lightweight propellant tank technologies (ULTT); and 5) propulsion technologies for a Mars Ascent Vehicle (MAV). The HEP system is composed of the High Voltage Hall Accelerator (HiVHAc) thruster, a power processing unit (PPU), and the XFCM. NEXT and the HiVHAc are throttle-able electric propulsion systems for planetary science missions. The XFCM and ULTT are two component technologies which being developed with nearer-term flight infusion in mind. Several of the ISPT technologies are related to sample return missions needs like: MAV propulsion and electric propulsion. And finally, one focus of the SystemsMission Analysis area is developing tools that aid the application or operation of these technologies on wide variety of mission concepts. This paper provides a brief overview of the ISPT program, describing the development status and technology infusion readiness.

propellant tanks↗

Status of Propulsion Technology Development Under the NASA In-space Propulsion Technology Program

Since 2001, the In-Space Propulsion Technology (ISPT) program has been developing and delivering in-space propulsion technologies for NASA's Science Mission Directorate (SMD). These in-space propulsion technologies are applicable, and potentially enabling for future NASA Discovery, New Frontiers, Flagship and sample return missions currently under consideration. The ISPT program is currently developing technology in three areas that include Propulsion System Technologies, Entry Vehicle Technologies, and Systems Mission Analysis. ISPT's propulsion technologies include: 1) the 0.6-7 kW NASA's Evolutionary Xenon Thruster (NEXT) gridded ion propulsion system; 2) a 0.3-3.9kW Hall-effect electric propulsion (HEP) system for low cost and sample return missions; 3) the Xenon Flow Control Module (XFCM); 4) ultra-lightweight propellant tank technologies (ULTT); and 5) propulsion technologies for a Mars Ascent Vehicle (MAV). The HEP system is composed of the High Voltage Hall Accelerator (HiVHAc) thruster, a power processing unit (PPU), and the XFCM. NEXT and the HiVHAc are throttle-able electric propulsion systems for planetary science missions. The XFCM and ULTT are two component technologies which being developed with nearer-term flight infusion in mind. Several of the ISPT technologies are related to sample return missions needs like: MAV propulsion and electric propulsion. And finally, one focus of the SystemsMission Analysis area is developing tools that aid the application or operation of these technologies on wide variety of mission concepts. This paper provides a brief overview of the ISPT program, describing the development status and technology infusion readiness.

electric propulsion↗

A DATA EFFICIENT SPARSE MODELING FRAMEWORK FOR POWER ESTIMATION IN WATER TREATMENT SENSING OPERATIONS

With increasing freshwater scarcity, advanced process design mechanisms such as Closed-Circuit Reverse Osmosis (CCRO) and Digital/Physical Twin systems are gaining traction in water treatment and reuse operations. While digital and physical twin models enable improved system insight and control, their development is often expensive and computationally intensive, requiring large volumes of synthetic or experimental data to characterize underlying process dynamics. This work introduces a sparse surrogate modeling framework to estimate power consumption from measured flow and pressure variables, along with their nonlinear polynomial and interaction expansions. To ensure model reliability and reduce overfitting, a two-stage pipeline is proposed. First, a dynamic data filtering algorithm is employed to remove uninformative observations and transient operational states. Second, a sparse penalized regression technique is applied to select a minimal set of parsimonious features. The proposed model achieves high sparsity, retaining only 7 out of 34 candidate features (≈79.41% sparsity) while delivering a root mean square error (RMSE) of 0.072 on the test dataset.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

Kiloampere, Variable-Temperature, Critical-Current Measurements of High-Field Superconductors

We review variable-temperature, transport critical-current ($I_\text{c}$) measurements made on commercial superconductors over a range of critical currents from less than 0.1 A to about 1 kA. We have developed and used a number of systems to make these measurements over the last 15 years. Two exemplary variable-temperature systems with coil sample geometries will be described: a probe that is only variable-temperature and a probe that is variable-temperature and variable-strain. The most significant challenge for these measurements is temperature stability, since large amounts of heat can be generated by the flow of high current through the resistive sample fixture. Therefore, a significant portion of this review is focused on the reduction of temperature errors to less than ±0.05 K in such measurements. A key feature of our system is a pre-regulator that converts a flow of liquid helium to gas and heats the gas to a temperature close to the target sample temperature. The pre-regulator is not in close proximity to the sample and it is controlled independently of the sample temperature. This allows us to independently control the total cooling power, and thereby fine tune the sample cooling power at any sample temperature. The same general temperature-control philosophy is used in all of our variable temperature systems, but the addition of another variable, such as strain, forces compromises in design and results in some differences in operation and protocol. These aspects are analyzed to assess the extent to which the protocols for our systems might be generalized to other systems at other laboratories. Our approach to variable-temperature measurements is also placed in the general context of measurement-system design, and the perceived advantages and disadvantages of design choices are presented. To verify the accuracy of the variable-temperature measurements, we compared critical-current values obtained on a specimen immersed in liquid helium (“liquid” or $I_{\text{c}}$ $_{\text{liq}}$) at 5 K to those measured on the same specimen in flowing helium gas (“gas” or Ic gas) at the same temperature. These comparisons indicate the temperature control is effective over the superconducting wire length between the voltage taps, and this condition is valid for all types of sample investigated, including Nb-Ti, Nb 3 Sn, and MgB 2 wires. The liquid/gas comparisons are used to study the variable-temperature measurement protocol that was necessary to obtain the “correct” critical current, which was assumed to be the $I_{\text{c}}$ $_{\text{liq}}$. We also calibrated the magnetoresistance effect of resistive thermometers for temperatures from 4 K to 35 K and magnetic fields from 0 T to 16 T. This calibration reduces systematic errors in the variable-temperature data, but it does not affect the liquid/gas comparison since the same thermometers are used in both cases.

47 OTHER INSTRUMENTATION↗

The aerodynamics of the curled wake: a simplified model in view of flow control

Abstract. When a wind turbine is yawed, the shape of the wake changes and a curled wake profile is generated. The curled wake has drawn a lot of interest because of its aerodynamic complexity and applicability to wind farm controls. The main mechanism for the creation of the curled wake has been identified in the literature as a collection of vortices that are shed from the rotor plane when the turbine is yawed. This work extends that idea by using aerodynamic concepts to develop a control-oriented model for the curled wake based on approximations to the Navier–Stokes equations. The model is tested and compared to time-averaged results from large-eddy simulations using actuator disk and line models. The model is able to capture the curling mechanism for a turbine under uniform inflow and in the case of a neutral atmospheric boundary layer. The model is then incorporated to the FLOw Redirection and Induction in Steady State (FLORIS) framework and provides good agreement with power predictions for cases with two and three turbines in a row.

17 WIND ENERGY↗

Testing- and Model- Based Optimization of Coal-fired Primary Heater Design for Indirect Supercritical CO 2 Power Cycles (Final Scientific and Technical Report)

The overall objective of this project was to perform the R&D necessary to mitigate the risk associated with the design of a primary heat exchanger for a solid-fired combustion system coupled with an indirect-fired closed-loop Brayton Cycle utilizing supercritical CO 2 . The key technological hurdle was the coupling of a solid-fuel firing system with the primary heater, which poses a singular challenge, which is the management of burner performance and operational conditions in a way to manage heat exchanger tube metal temperatures and temperature ramp rates in the absence of fluid phase change on the inside of the tubes. We designed and built the first ever pseudo power system employing a simple recuperated supercritical CO 2 closed-loop Brayton Cycle coupled to a solid-fuel fired system. Advanced coupled CFD and process modeling were used to design the primary heat exchanger (PHX), which consisted of both radiative and convective sections, to limit tube metal temperatures resulting from the heat release profile of the solid fuel flame near the radiative tubes. The heat exchanger was designed to produce finished CO 2 temperatures of 600 °C a pressure of 20.7 MPa and CO 2 flow of 5.5 kg/s. The constructed PHX was capable of 1.2 MWth heat uptake. During design of the PHX, the modeling showed that most variables influencing flame shape (burner stoichiometric ratio and register velocities and swirl) were not suitable to manage heat flux to the metal surfaces. This is because they substantially increased adiabatic flame temperature through the influence of localized stoichiometric ratio. Excess air and firing rate were the two most powerful variables that could be used to control tube surface temperatures. The coupled system was operated for a total of 407 hours, with the longest continuous run of 248 hours. For 62% of the operational time, the unit was unmanned and in automatic control. The fuels used for the testing included natural gas, two Utah Bituminous coals, woody biomass, and bagasse. During the testing we were able to verify the 1.2 MWth heat uptake and we operated at a finished CO 2 temperature of 607 °C and a pressure of 20.3 MPa simultaneously. The real-time corrosion rate of the Super 304H tube CO 2 surface in the region of the radiative section of the PHX were measured, at an approximate temperature of 550 °C. The two key variables related to corrosion rate are the pressure and flow rate of the CO 2 . A technoeconomic analysis was performed at a scale of 120 MWE. The updated analysis showed that the efficiency of an sCO 2 power producing plant will be related to the pressure drop of the PHX.

01 COAL, LIGNITE, AND PEAT↗