Search NASA⌕ Search

SEARCH · Search NASA

Results for “Project X”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

The X-ray view of optically selected dual AGN

We present a study of optically selected dual Active Galactic Nuclei (AGN) with projected separations of 3–97 kpc. Using multiwavelength (MWL) information (optical, X-ray, mid-IR), we characterized the intrinsic nuclear properties of this sample and compared them with those of isolated systems. Among the 124 X-ray-detected AGN candidates, 52 appear in pairs and 72 as single X-ray sources. Through MWL analysis, we confirmed the presence of the AGN in >80 per cent of the detected targets in pairs (42 out of 52). X-ray spectral analysis confirms the trend of increasing AGN luminosity with decreasing separation, suggesting that mergers may have contributed to triggering more luminous AGN. Through X-ray/mid-IR ratio versus X-ray colours, we estimated a fraction of Compton-thin AGN (with 10 22 cm −2 < N H < 10 24 cm −2 ) of about 80 per cent, while about 16 per cent are Compton-thick sources (with N H > 10 24 cm −2 ). These fractions of obscured sources are larger than those found in samples of isolated AGN, confirming that pairs of AGN show higher obscuration. This trend is further confirmed by comparing the de-reddened [O III ] emission with the observed X-ray luminosity. However, the derived fraction of Compton-thick sources in this sample at the early stages of merging is lower than that reported for late-merging dual-AGN samples. Comparing N H from X-rays with that derived from E(B − V ) from narrow-line regions, we found that the absorbing material is likely to be associated with the torus or broad-line regions. We also explored the X-ray detection efficiency of dual-AGN candidates, finding that, when observed properly (at on-axis positions and with long exposures), X-ray data represent a powerful way to confirm and investigate dual-AGN systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Accurate Holdup Calculations with Predictive Modeling & Data Integration

In facilities that process special nuclear material (SNM) it is important to account accurately for the fissile material that enters and leaves the plant. Although there are many stages and processes through which materials must be traced and measured, the focus of this project is material that is “held-up” in equipment, pipes, and ducts during normal operation and that can accumulate over time into significant quantities. Accurately estimating the holdup is essential for proper SNM accounting (vis-à-vis nuclear non-proliferation), criticality and radiation safety, waste management, and efficient plant operation. Usually it is not possible to directly measure the holdup quantity and location, so these must be inferred from measured radiation fields, primarily gamma and less frequently neutrons. Current methods to quantify holdup, i.e. Generalized Geometry Holdup (GGH), primarily rely on simple source configurations and crude radiation transport models aided by ad hoc correction factors. This project seeks an alternate method of performing measurement-based holdup calculations using a predictive model that employs state-of-the-art radiation transport codes capable of accurately simulating such situations. Inverse and data assimilation methods use the forward transport model to search for a source configuration that best matches the measured data and simultaneously provide an estimate of the level of confidence in the correctness of such configuration. In this work the holdup problem is re-interpreted as an inverse problem that is under-determined, hence may permit multiple solutions. A probabilistic approach is applied to solving the resulting inverse problem. This approach rates possible solutions according to their plausibility given the measurements and initial information. This is accomplished through the use of Bayes’ Theorem that resolves the issue of multiple solutions by giving an estimate of the probability of observing each possible solution. To use Bayes’ Theorem, one must have a model y(x) that maps the state variables x (the solution in this case) to the measurements y. In this case, the unknown state variables are the configuration and composition of the heldup SNM. The measurements are the detector readings. Thus, the natural model is neutral-particle radiation transport where a wealth of computational tools exists for performing these simulations accurately and efficiently. The combination of predictive model and Bayesian inference forms the Data Integration with Modeled Predictions (DIMP) method that serves as foundation for this project. The cost functional describing the model-to-data misfit is computed via a norm created by the inverse of the covariance matrix of the model parameters and responses. Since the model y(x) for the holdup problem is nonlinear, a nonlinear optimization on Q is conducted via Newton-type iterative methods to find the optimal values of the model parameters x. This project comprised a collaboration between NC State University (NCSU), the University of South Carolina (USC), and Oak Ridge National Laboratory (ORNL). The project was originally proposed in seven main tasks with an eighth contingency task to be performed if time and funding permitted; in fact time did not permit commencement of the contingency task and it was not performed. The remaining tasks involved holdup analysis with gamma detection strategies and separately with neutrons based on coincidence counting. Early in the project, and upon consultation with experts in coincidence counting it became evident that this approach is not viable for holdup applications and this task was replaced with an alternative, but valuable investigation that was carried out by the USC partner. Nevertheless, the experimental 4 measurements at ORNL of both gamma and neutron sources for the purpose of constructing Detector Response Functions (DRFs) with the associated uncertainties were indeed completed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TH-AB-209-07: High Resolution X-Ray-Induced Acoustic Computed Tomography

Purpose: X-ray radiographic absorption imaging is an invaluable tool in medical diagnostics, biology and materials science. However, the use of conventional CT is limited by two factors: the detection sensitivity to weak absorption material and the radiation dose from CT scanning. The purpose of this study is to explore X-ray induced acoustic computed tomography (XACT), a new imaging modality, which combines X-ray absorption contrast and high ultrasonic resolution to address these challenges. Methods: First, theoretical models was built to analyze the XACT sensitivity to X-ray absorption and calculate the minimal radiation dose in XACT imaging. Then, an XACT system comprised of an ultrashort X-ray pulse, a low noise ultrasound detector and a signal acquisition system was built to evaluate the X-ray induced acoustic signal generation. A piece of chicken bone and a phantom with two golden fiducial markers were exposed to 270 kVp X-ray source with 60 ns exposure time, and the X-ray induced acoustic signal was received by a 2.25MHz ultrasound transducer in 200 positions. XACT images were reconstructed by a filtered back-projection algorithm. Results: The theoretical analysis shows that X-ray induced acoustic signals have 100% relative sensitivity to X-ray absorption, but not to X-ray scattering. Applying this innovative technology to breast imaging, we can reduce radiation dose by a factor of 50 compared with newly FDA approved breast CT. The reconstructed images of chicken bone and golden fiducial marker phantom reveal that the spatial resolution of the built XACT system is 350µm. Conclusion: In XACT, the imaging sensitivity to X-ray absorption is improved and the imaging dose is dramatically reduced by using ultrashort pulsed X-ray. Taking advantage of the high ultrasonic resolution, we can also perform 3D imaging with a single X-ray pulse. This new modality has the potential to revolutionize x-ray imaging applications in medicine and biology.

60 APPLIED LIFE SCIENCES↗

Test results of a counting type SOI device for a new x-ray area detector

Development of a new detector using Silicon-On-Insulator (SOI) technology has been started in the Photon Factory, KEK. The aim of this project is to develop a pulse-counting-type X-ray detector that can be used in synchrotron radiation experiments using soft X-rays. We started to make a Test Element Group of SOI chip, which is called CPIXPTEG1 and evaluated its performance. We succeeded in readout of output signals for 16 keV X-rays from the SOI chips. We also found that the middle-SOI structure was effective against a signal distortion caused by hole traps in the buried oxide layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE HALO OCCUPATION DISTRIBUTION OF X-RAY-BRIGHT ACTIVE GALACTIC NUCLEI: A COMPARISON WITH LUMINOUS QUASARS

We perform halo occupation distribution (HOD) modeling of the projected two-point correlation function (2PCF) of high-redshift (z {approx} 1.2) X-ray-bright active galactic nuclei (AGNs) in the XMM-COSMOS field measured by Allevato et al. The HOD parameterization is based on low-luminosity AGNs in cosmological simulations. At the median redshift of z {approx} 1.2, we derive a median mass of 1.02{sub -0.23}{sup +0.21} Multiplication-Sign 10{sup 13} h{sup -1} M{sub sun} for halos hosting central AGNs and an upper limit of {approx}10% on the AGN satellite fraction. Our modeling results indicate (at the 2.5{sigma} level) that X-ray AGNs reside in more massive halos compared to more bolometrically luminous, optically selected quasars at similar redshift. The modeling also yields constraints on the duty cycle of the X-ray AGN, and we find that at z {approx} 1.2 the average duration of the X-ray AGN phase is two orders of magnitude longer than that of the quasar phase. Our inferred mean occupation function of X-ray AGNs is similar to recent empirical measurements with a group catalog and suggests that AGN halo occupancy increases with increasing halo mass. We project the XMM-COSMOS 2PCF measurements to forecast the required survey parameters needed in future AGN clustering studies to enable higher precision HOD constraints and determinations of key physical parameters like the satellite fraction and duty cycle. We find that N {sup 2}/A {approx} 5 Multiplication-Sign 10{sup 6} deg{sup -2} (with N the number of AGNs in a survey area of A deg{sup 2}) is sufficient to constrain the HOD parameters at the 10% level, which is easily achievable by upcoming and proposed X-ray surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental Study of the Fundamental Properties of Warm Dense Mixtures

The aim of the proposed research was to provide a multi-scale study of the properties of warm dense hydrocarbons, by studying the thermodynamic properties through the equation of state and the microscopic properties by x-ray scattering. Understanding the fundamental properties of warm dense mixtures is an intellectual challenge due to the complexity of the system. Unlike liquids or gases, where constituent particle interactions occur through collisions or bonding between valence electrons, in these strongly coupled systems the atoms will be partially ionized and compressed so tightly together that interactions between the inner core electrons can play a role in the systems chemistry. Advances in computational capabilities and development of new theoretical models have been used to predict the properties of mixtures but there is currently no experimental data of the fundamental interaction between the particles in mixtures to test these predictions against. The proposed research was to experimentally investigate the interaction of the different species in hydrocarbons by measuring the compressibility of substances with different carbon and hydrogen ratios and the complexity of the microscopic interactions through elastic and inelastic x-ray scattering. To study the bulk properties of warm dense hydrocarbons we established the Warm Dense Matter Research Laboratory (WDMRL) in the Institute for Shock Physics at Washington State University. The goal was for experiments in the WDMRL to determine shock loading conditions of interest in the hydrocarbon mixtures. We planned on using Hugoniot EOS measurements and a range of carbon and hydrogen concentrations to determine conditions when the EOS of the mixture varied significantly from that of the classical mixing model. Even though shock transit measurements through aluminum foils suggested pressures upto 400GPa, the experiments in the WDMRL were unsuccessful in getting usable shockwave compression data above 100GPa in polystyrene which was below the pressure of interest for hydrocarbon mixtures (>200GPa). To complete the project, we tested a technique using x-ray phase contrast imaging to map the location of tracer layers in a test sample of polycarbonate to record the material motion in dynamically compressed samples. A technique that will be useful for future warm dense matter experiments. These experiments used <200nm gold layers in polycarbonate samples to measure the material velocity and shock speed using x-ray phase contrast imaging. These results were compared to continuum surface measurements performed at ISP and show that the tracer layer technique can measure hydrodynamic properties accurately in dynamically compressed materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CIZA: The First Systematic X-Ray Search for Clusters of Galaxies Behind the Milky Way

The aim of the CIZA project (Clusters In the Zone of Avoidance) was to take the first step toward a complete X-ray census of clusters of galaxies behind the plane of the Galaxy (the absolute value of b less than or equal to 20 degrees), the historical Zone of Avoidance of optical extragalactic surveys. Finding these heavily obscured clusters in ROSAT All-Sky Survey data would allow us to: 1. Construct the first truly all-sky, statistically complete, X-ray flux limited sample of galaxy clusters; 2. Use this sample to obtain an improved measurement of the cluster dipole (both amplitude and direction); 3. Chart large-scale structure across the plane of the Milky Way as traced by galaxy clusters; 4. Identify potential massive galaxy clusters contributing to the observed large-scale flow pattern in the local universe, specifically in the region around the Great Attractor; and 5. Use least-action modelling to deduce the gravitational fields created by galaxy clusters and compare this reconstruction with the one obtained from local galaxy surveys. Our project was highly successful in demonstrating the feasibility of this undertaking and allowed substantial progress toward achieving the stated science goals.

Ebeling, Harald↗

Development of a Turbulent Liquid Spray Atomization Model for Diesel Engine Simulations (Final Technical Report)

This project addresses the systematic lack of predictive capabilities by spray models within engine CFD codes. We develop a new modeling approach to predict the breakup of diesel sprays based on recent literature showing that liquid turbulence plays a fundamental role in spray atomization. A new body of quantitative validation data is also developed as a critical element of the project, leveraging the joint capabilities of Georgia Tech’s high-pressure continuous-flow spray chamber and Argonne National Lab’s near-nozzle x-ray diagnostics at the Advanced Photon Source. This project contributes spatially-resolved measurements of drop size distribution within well-characterized diesel injectors, Spray A and D, from the Engine Combustion Network (ECN) to the engine combustion community for the first time. Utilizing this new body of measurements, we validate and demonstrate a new spray model for diesel sprays, termed the KH-Faeth model, that predicts global and local spray characteristic more accurately than the widely adopted and employed KH model. Predicted drop size distributions are seen to predict measured drops sizes both quantitatively and predictively, with accurate response in droplet size distributions over a wide range of ambient density, injection pressure, and injector nozzle size (Spray A and D) without model tuning. The KH-Faeth model can reduce error in the predicted centerline droplet size profile by up to 80% for ECN Spray D simulations when compared to use of the widely employed KH model.

33 ADVANCED PROPULSION SYSTEMS↗

PPPL Laboratory Directed Research and Development (Project Final Reports, FY2018 - FY2020)

The U.S. Department of Energy’s (DOE) Princeton Plasma Physics Laboratory (PPPL) is a collaborative national center for fusion energy science, basic sciences, and advanced technology. The Laboratory has three major missions: (1) to develop the scientific knowledge and advanced engineering to enable fusion to power the U.S. and the world; (2) to advance the science of nanoscale fabrication for technologies of tomorrow; and (3) to further the development of the scientific understanding of the plasma universe from laboratory to astrophysical scales. PPPL’s Laboratory Directed Research and Development (LDRD) program supports and encourages creativity and innovation and contributes to its long-term viability. New scientific and technical research areas emerge and are nurtured through the program. Furthermore, new capabilities are developed to enable the Laboratory to meet its and DOE’s missions. The program is used to systematically diversify the Laboratory’s programs and mission. In the last few years, the program has started projects in nanomaterial synthesis, microelectronics, advanced x-ray spectroscopy, high-energy-density physics, superconducting magnet technology, machine learning and artificial intelligence, 3D magnetic fields to optimize fusion plasmas, integration of permanent magnets with simple high-field magnets to reduce the cost of producing complex 3D magnetic fields, advanced computational methods for predictive understanding and control of fusion plasma, development of quantum computing algorithms for plasma physics, liquid metal plasma-facing components for fusion reactors, virtual engineering, and plasma-based space propulsion. The program is also the vehicle to recruit and train talented scientists and engineers with the new skills needed to perform the Laboratory’s mission. Many of the new hires through the program go on to become world-class scientists and engineers in their fields. This report provides descriptions and accomplishments of those LDRD projects that were completed during fiscal years 2018 through 2020.

36 MATERIALS SCIENCE↗

A COMBINED LOW-RADIO FREQUENCY/X-RAY STUDY OF GALAXY GROUPS. I. GIANT METREWAVE RADIO TELESCOPE OBSERVATIONS AT 235 MHz AND 610 MHz

We present new Giant Metrewave Radio Telescope observations at 235 MHz and 610 MHz of 18 X-ray bright galaxy groups. These observations are part of an extended project, presented here and in future papers, which combines low-frequency radio and X-ray data to investigate the interaction between central active galactic nuclei (AGNs) and the intra-group medium (IGM). The radio images show a very diverse population of group-central radio sources, varying widely in size, power, morphology, and spectral index. Comparison of the radio images with Chandra and XMM-Newton X-ray images shows that groups with significant substructure in the X-ray band and marginal radio emission at {approx}>1 GHz host low-frequency radio structures that correlate with substructures in IGM. Radio-filled X-ray cavities, the most evident form of AGN/IGM interaction in our sample, are found in half of the systems and are typically associated with small, low-, or mid-power double radio sources. Two systems, NGC5044 and NGC4636, possess multiple cavities, which are isotropically distributed around the group center, possibly due to group weather. In other systems the radio/X-ray correlations are less evident. However, the AGN/IGM interaction can manifest itself through the effects of the high-pressure medium on the morphology, spectral properties, and evolution of the radio-emitting plasma. In particular, the IGM can confine fading radio lobes in old/dying radio galaxies and prevent them from dissipating quickly. Evidence for radio emission produced by former outbursts that co-exist with current activity is found in six groups of the sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative phase retrieval with picosecond X-ray pulses from the ATF Inverse Compton Scattering source

Quantitative phase retrieval is experimentally demonstrated using the Inverse Compton Scattering X-ray source available at the Accelerator Test Facility (ATF) in the Brookhaven National Laboratory. Phase-contrast images are collected using in-line geometry, with a single X-ray pulse of approximate duration of one picosecond. The projected thickness of homogeneous samples of various polymers is recovered quantitatively from the time-averaged intensity of transmitted X-rays. The data are in good agreement with the expectations showing that ATF Inverse Compton Scattering source is suitable for performing phase-sensitive quantitative X-ray imaging on the picosecond scale. The method shows promise for quantitative imaging of fast dynamic phenomena.

43 PARTICLE ACCELERATORS↗

The evolution of a rapidly-expanding active region loop into a trans-equatorial coronal mass ejection

On 23 February 1997, a coronal mass ejection erupted off the NE limb of the sun from a coronal loop system which had earlier been visible soft X-rays and Fe XIV. The ejection coincided with the onset of a small soft X-ray event, and it left the corona at a position angle of around 60 deg at around 880 km s(exp -1). This ejection then merged with a much larger event which spanned the equator and became indistinguishable, in projection, with the primary event. The soft X-ray images indicate that the highest temperature plasma was associated with the loop system near the original erupting loop. A large loop system became visible south of the equator as the coronal mass ejection developed. It appears that there are high closed coronal magnetic loops linking the northern region to that in the south.

Simnett, G. M.↗

Analysis of Combustion Systems

As part of the NASA High-Speed Research Program, low emission combustors are being studied and demonstrated. One combustor concept that is currently being studied and evaluated is the Rich burn-Quick mix-Lean burn (RQL) combustor. The quick-mix zone of the RQL combustor is extremely important in reducing NO(x) emissions; rapid mixing of the bypass airflow with rich-born effluent is essential. The basic challenge can be described as rapid jet-in-crossflow mixing. Although jet-in-crossflow mixing is not new, this RQL application is unique in that the jet-to-mainstream mass-flow ratios are higher than studied previously (approx. 3 in RQL applications versus approx. 0.5 in dilution zone studies), plus the emphasis is on reducing NO(x) emissions (i.e. good mixing might not necessarily produce low emissions). This five-years project focused on identifying quick-mix method that would reduce NO(x) emissions in RQL combustor. The work included study of mixing concepts, and the development of design methodology. Three dimension CFD analysis was the primary tool used in assessing concept and developing design methodology for low emission. Isothermal and reacting CFD calculations were performed on cylindrical, rectangular, and annular generic geometries. Systematic parameters studies were performed to isolate key design parameters and their influence on mixing and emissions.

Daniel B. Bain↗

Advanced Compact X-ray Spectrometer with High Resolution and Efficiency

Under this Phase I SBIR Project, the Square One engineering team (in collaboration with a team of scientists from Brookhaven National Laboratory) designed, built, and tested a prototype Modular X-Ray Detection System. This Detection System was comprised of two primary subsystems, the Aiming Mechanism and the Optics Train. The Optics Train can be further subdivided into the following three components: the Collection Optic, the Discrimination Optic, and the Detection Unit. It is these three components that determine the modularity of the System. For example, the Collection Optic could accommodate either a polycapillary half lens or a Soller Slit. Similarly, the Detection Unit could accommodate either a Silicon Drift Diode (SDD) or some other diode. The Discrimination Optic can be included in the Optics Train, but is not necessary to the operation of the System.

99 GENERAL AND MISCELLANEOUS↗

Hard x-ray transmission crystal spectrometer at the OMEGA-EP laser facility

The transmission crystal spectrometer (TCS) is approved for taking data at the OMEGA-EP laser facility since 2009 and will be available for the OMEGA target chamber in 2010. TCS utilizes a Cauchois type cylindrically bent transmission crystal geometry with a source to crystal distance of 600 mm. Spectral images are recorded by image plates in four positions, one IP on the Rowland circle and three others at 200, 400, and 600 mm beyond the Rowland circle. An earlier version of TCS was used at LULI on experiments that determined the x-ray source size from spectral line broadening on one IP positioned behind the Rowland circle. TCS has recorded numerous backlighter spectra at EP for point projection radiography and for source size measurements. Hard x-ray source size can be determined from the source broadening of both K shell emission lines and from K absorption edges in the bremsstrahlung continuum, the latter being a new way to measure the spatial extent of the hard x-ray bremsstrahlung continuum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SUZAKU X-RAY FOLLOW-UP OBSERVATIONS OF SEVEN UNASSOCIATED FERMI-LAT GAMMA-RAY SOURCES AT HIGH GALACTIC LATITUDES

We report on our second-year campaign of X-ray follow-up observations of unidentified Fermi Large Area Telescope (LAT) {gamma}-ray sources at high Galactic latitudes (|b| > 10 Degree-Sign ) using the X-ray Imaging Spectrometer on board the Suzaku X-ray Observatory. In this second year of the project, seven new targets were selected from the First Fermi-LAT Catalog, and studied with 20-40 ks effective Suzaku exposures. We detected an X-ray point source coincident with the position of the recently discovered millisecond pulsar (MSP) PSR J2302+4442 within the 95% confidence error circle of 1FGL J2302.8+4443. The X-ray spectrum of the detected counterpart was well fit by a blackbody model with temperature of kT {approx_equal} 0.3 keV, consistent with an origin of the observed X-ray photons from the surface of a rotating magnetized neutron star. For four other targets that were also recently identified with a normal pulsar (1FGL J0106.7+4853) and MSPs (1FGL J1312.6+0048, J1902.0-5110, and J2043.2+1709), only upper limits in the 0.5-10 keV band were obtained at the flux levels of {approx_equal} 10{sup -14} erg cm{sup -2} s{sup -1}. A weak X-ray source was found in the field of 1FGL J1739.4+8717, but its association with the variable {gamma}-ray emitter could not be confirmed with the available Suzaku data alone. For the remaining Fermi-LAT object 1FGL J1743.8-7620 no X-ray source was detected within the LAT 95% error ellipse. We briefly discuss the general properties of the observed high Galactic-latitude Fermi-LAT objects by comparing their multiwavelength properties with those of known blazars and MSPs.

79 ASTRONOMY AND ASTROPHYSICS↗

A statistically defined anthropomorphic software breast phantom

Purpose: Digital anthropomorphic breast phantoms have emerged in the past decade because of recent advances in 3D breast x-ray imaging techniques. Computer phantoms in the literature have incorporated power-law noise to represent glandular tissue and branching structures to represent linear components such as ducts. When power-law noise is added to those phantoms in one piece, the simulated fibroglandular tissue is distributed randomly throughout the breast, resulting in dense tissue placement that may not be observed in a real breast. The authors describe a method for enhancing an existing digital anthropomorphic breast phantom by adding binarized power-law noise to a limited area of the breast. Methods: Phantoms with (0.5 mm){sup 3} voxel size were generated using software developed by Bakic et al. Between 0% and 40% of adipose compartments in each phantom were replaced with binarized power-law noise ({beta} = 3.0) ranging from 0.1 to 0.6 volumetric glandular fraction. The phantoms were compressed to 7.5 cm thickness, then blurred using a 3 Multiplication-Sign 3 boxcar kernel and up-sampled to (0.1 mm){sup 3} voxel size using trilinear interpolation. Following interpolation, the phantoms were adjusted for volumetric glandular fraction using global thresholding. Monoenergetic phantom projections were created, including quantum noise and simulated detector blur. Texture was quantified in the simulated projections using power-spectrum analysis to estimate the power-law exponent {beta} from 25.6 Multiplication-Sign 25.6 mm{sup 2} regions of interest. Results: Phantoms were generated with total volumetric glandular fraction ranging from 3% to 24%. Values for {beta} (averaged per projection view) were found to be between 2.67 and 3.73. Thus, the range of textures of the simulated breasts covers the textures observed in clinical images. Conclusions: Using these new techniques, digital anthropomorphic breast phantoms can be generated with a variety of glandular fractions and patterns. {beta} values for this new phantom are comparable with published values for breast tissue in x-ray projection modalities. The combination of conspicuous linear structures and binarized power-law noise added to a limited area of the phantom qualitatively improves its realism.

60 APPLIED LIFE SCIENCES↗

Small, Inexpensive Combined NOx and O2 Sensor

It has been successfully demonstrated in this program that a zirconia multilayer structure with rhodium-based porous electrodes performs well as an amperometric NO{sub x} sensor. The sensitivity of the sensor bodies operating at 650 to 700 C is large, with demonstrated current outputs of 14 mA at 500 ppm NO{sub x} from sensors with 30 layers. The sensor bodies are small (4.5 x 4.2 x 3.1 mm), rugged, and inexpensive. It is projected the sensor bodies will cost $5-$10 in production. This program has built on another successful development program for an oxygen sensor based on the same principles and sponsored by DOE. This oxygen sensor is not sensitive to NO{sub x}. A significant technical hurdle has been identified and solved. It was found that the 100% Rh electrodes oxidize rapidly at the preferred operating temperatures of 650-700 C, and this oxidation is accompanied by a volume change which delaminates the sensors. The problem was solved by using alloys of Rh and Pt. It was found that a 10%/90% Rh/Pt alloy dropped the oxidation rate of the electrodes by orders of magnitude without degrading the NO{sub x} sensitivity of the sensors, allowing long-term stable operation at the preferred operating temperatures. Degradation in the sensor output caused by temperature cycling was identified as a change in resistance at the junction between the sensor body and the external leads attached to the sensor body. The degradation was eliminated by providing strong mechanical anchors for the wire and processing the junctions to obtain good electrical bonds. The NO{sub x} sensors also detect oxygen and therefore the fully-packaged sensor needs to be enclosed with an oxygen sensor in a small, heated zirconia chamber exposed to test gas through a diffusion plug which limits the flow of gas from the outside. Oxygen is pumped from the interior of the chamber to lower the oxygen content and the combination of measurements from the NO{sub x} and oxygen sensors yields the NO{sub x} content of the gas. Two types of electronic control units were designed and built. One control unit provides independent constant voltages to the NOx and oxygen sensors and reads the current from them (that is, detects the amount of test gas present). The second controller holds the fully-assembled sensor at the desired operating temperature and controllably pumps excess oxygen from the test chamber. While the development of the sensor body was a complete success, the development of the packaging was only partially successful. All of the basic principles were demonstrated, but the packaging was too complex to optimize the operation within the resources of the program. Thus, no fully-assembled sensors were sent to outside labs for testing of cross-sensitivities, response times, etc. Near the end of the program, Sensata Technologies of Attleboro, MA tested the sensor bodies and confirmed the CeramPhysics measurements as indicated in the following attached letter. Sensata was in the process of designing their own packaging for the sensor and performing cross-sensitivity tests when they stopped all sensor development work due to the automotive industry downturn. Recently Ceramatec Inc. of Salt Lake City has expressed an interest in testing the sensor, and other licensing opportunities are being pursued.

47 OTHER INSTRUMENTATION↗