At least 1,153 records · Page 64

A volatile fluid assisted thermo-pneumatic liquid metal energy harvester

A close-cycle self-driving thermal energy harvester using liquid metal as energy carrier fluid has been proposed. The driving force that pushes the liquid metal against flow resistance and gravity is provided by a resistively heated volatile fluid based on thermo-pneumatic principle. The tested harvester prototype demonstrated its capability to extract thermal energy between small temperature gradient, at a scale of 10 °C. During a 5-h operation, it further demonstrated robust liquid metal recirculating performance at a time-average volume flow rate of 14 ml/min with a 12.25 W heating load. The prototype also managed to self-adjust to variable working conditions which indicated the reliability of this method. Advantages of this method include simple-structural design, rigid-motion free operation, and low-temperature actuation. These advantages make it uniquely suited for solar energy and low-grade heat harvesting, high heat flux electronics cooling, as well as autonomous machines actuating.

42 ENGINEERING↗

So What's an RTG and Are They Safe?

When one considers space missions to the outer edges of our solar system and far beyond, our sun cannot be relied on to produce the required spacecraft (s/c) power. Solar energy diminishes as the square of the distance from the Sun. At Mars it is only 43% of that at earth. At Jupiter, it falls off to only 3.6% of Earth's. By the time we get out to Pluto, solar energy is only .066% what it is on Earth. Beyond the orbit of Mars, it is not practical to depend on solar power for a s/c. However, the farther out we go the more power we need to heat the s/c and to transmit data back to Earth over the long distances. On Earth, knowledge is power. In the outer solar system, power is knowledge. Solar arrays only operate at 19% efficiency, are very vulnerable to damage from radiation and temperature extremes, and cannot be used for even nearby missions that operate in extended darkness, or under the surface of a planet or moon. Twenty-six U.S. space missions, from the Transit to Cassini, have used radioisotope power systems and heater units to take s/c to the far reaches of our solar system and have demonstrated an outstanding record of safety and reliability. Radioisotope thermoelectric generators (RTG's) have proven to be safe, reliable, maintenance-free, and capable of providing both thermal and electrical power for decades under the harsh environments of deep space. RTG's have no problem operating in the high radiation belts of space, the extreme temperatures, or the severe dust storms of Mars, and they have proven to be the most reliable power source ever flown on U.S. s/c. For example, the two Pioneer s/c operated for more than two decades and the Voyager s/c may last for 40 years. RTG's are not nuclear reactors, they serve only as power generators and are not involved in the propulsion of the s/c. They operate on the principle of thermoelectric generation that converts heat directly into electricity, they have no moving parts, are extremely reliable, and have met or exceeded all safety and performance expectations. Federal laws and regulations require analysis and evaluation of the safety risks and any potential environmental impacts. Extensive safety testing of RTG's and RTG components has been performed by the U.S. Department of Energy (DOE) to demonstrate the ability to survive accidents related to Space Shuttle launches and assure that the systems would be safe under all accident conditions, including accidents at or near the launch pad or during orbital reentry. Many design improvements have been made over the four decades that RTG's have been flown on space missions. This paper outlines the operation and safety standards of RTG's and the advanced developments expected to be used on future deep space missions such as the Europa Orbiter, Pluto/Kuiper Express, Solar Probe, Europa Lander, and Titan Explorer missions.

Barret, Chris↗

SAPHIRE 8 Volume 5 - Workspaces

The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Version 8 is a software application developed for performing a complete probabilistic risk assessment using a personal computer running the Microsoft Windows™ operating system. SAPHIRE 8 is funded by the U.S. Nuclear Regulatory Commission (NRC). The role of the Idaho National Laboratory (INL) in this project is that of software developer and tester. In older versions of SAPHIRE, the model creation and analysis functions were intermingled. However, in SAPHIRE 8, the act of creating a model has been separated from the analysis of that model in order to improve the quality of both the model (e.g., by avoiding inadvertent changes) and the analysis. Consequently, in SAPHIRE 8, the analysis of models is performed by using what are called Workspaces. Currently, there are Workspaces for three types of analyses: (1) the NRC’s Accident Sequence Precursor program, where the workspace is called “Events and Condition Assessment (ECA);” (2) the NRC’s Significance Determination Process (SDP); and (3) the General Analysis (GA) workspace. Workspaces for each type are created and saved separately from the base model which keeps the original database intact. Workspaces are independent of each other and modifications or calculations made within one workspace will not affect another. In addition, each workspace has a user interface and reports tailored for their intended uses.

99 GENERAL AND MISCELLANEOUS↗

Computational Modeling of Molten Salt Infiltration and Oxidation in Nuclear Graphite

Graphite is utilized as a moderator and reflector in advanced nuclear reactor designs due to its high thermal conductivity, neutron moderation properties, and resistance to radiation damage. However, its longterm performance and reliability are challenged by degradation mechanisms such as molten salt infiltration in molten salt reactors (MSRs) and oxidation in gas-cooled reactors (GCRs). These mechanisms can compromise the structural integrity and operational lifetime of graphite components, necessitating a more detailed assessment of their physical behavior. This report focuses on the development of computational models for molten salt infiltration and oxidation of graphite to aid the design and performance analysis of graphite components. For molten salt infiltration, a computational framework is developed that couples incompressible Navier-Stokes and phase-field model to simulate the penetration of molten salt into graphite?s interconnected pore structure. Initial model verification is performed using two-phase flows in two dimensions, demonstrating the models ability to capture fundamental physical behavior and agree with analytical solution. This framework is then applied to a realistic IG110 nuclear graphite , where a computed tomography extracted pore geometry is used to analyse the infiltration behavior of FLiNaK molten salt. This model provides insights into how the microstructure and other relevant parameters influence the transport pathways of molten salt into graphite, potentially offering a means to rapidly evaluate a graphite grade?s resistance to infiltration. For oxidation, the report details pore-scale mass and heat transport models, describing the diffusion of gases, reaction kinetics, and thermal effects. Additionally, this report highlights inconsistencies in the existing volume-averaged macroscopic model, particularly in upscaling of reaction kinetics and flux terms, and surface to volume transformations. These inconsistencies suggest that current formulations may not accurately capture the experimentally observed graphite oxidation process, highlighting the need for improved model development. This work advances the development of physics-based computational models for graphite degradation, contributing to improved predictive models for next-generation nuclear reactor designs. Future efforts will focus on refining the infiltration model to address non-physical behaviors and enhance its robustness. Additionally, for oxidation, further studies will employ the principles of volume averaging to rigorously derive the upscaled equations, potentially in collaboration with subject matter experts.

Computational Modeling of Molten Salt Infiltration↗

High-Performance Computing for Advanced Smart Grid Applications

The power grid is becoming far more complex as a result of the grid evolution meeting an information revolution. Due to the penetration of smart grid technologies, the grid is evolving as an unprecedented speed and the information infrastructure is fundamentally improved with a large number of smart meters and sensors that produce several orders of magnitude larger amounts of data. How to pull data in, perform analysis, and put information out in a real-time manner is a fundamental challenge in smart grid operation and planning. The future power grid requires high performance computing to be one of the foundational technologies in developing the algorithms and tools for the significantly increased complexity. New techniques and computational capabilities are required to meet the demands for higher reliability and better asset utilization, including advanced algorithms and computing hardware for large-scale modeling, simulation, and analysis. This chapter summarizes the computational challenges in smart grid and the need for high performance computing, and present examples of how high performance computing might be used for future smart grid operation and planning.

computational challenges↗

Southern Nevada Alternative Fuels Demonstration Project

The Southern Nevada Alternative Fuels Program is designed to demonstrate, in a day-to-day bus operation, the reliability and efficiency of a hydrogen bus operation under extreme conditions. By using ICE technology and utilizing a virtually emission free fuel, benefits to be derived include air quality enhancement and vehicle performance improvements from domestically produced, renewable energy sources. The project objective is to help both Ford and the City demonstrate and evaluate the performance characteristics of the E-450 H2ICE shuttle buses developed by Ford, which use a 6.8-liter supercharged Triton V-10 engine with a hydrogen storage system equivalent to 29 gallons of gasoline. The technology used during the demonstration project in the Ford buses is a modified internal combustion engine that allows the vehicles to run on 100% hydrogen fuel. Hydrogen gives a more thorough fuel burn which results in more power and responsiveness and less pollution. The resultant emissions from the tailpipe are 2010 Phase II compliant with NO after treatment. The City will lease two of these E-450 H2ICE buses from Ford for two years. The buses are outfitted with additional equipment used to gather information needed for the evaluation. Performance, reliability, safety, efficiency, and rider comments data will be collected. The method of data collection will be both electronically and manually. Emissions readings were not obtained during the project. The City planned to measure the vehicle exhaust with an emissions analyzer machine but discovered the bus emission levels were below the capability of their machine. Passenger comments were solicited on the survey cards. The majority of comments were favorable. The controllable issues encountered during this demonstration project were mainly due to the size of the hydrogen fuel tanks at the site and the amount of fuel that could be dispensed during a specified period of time. The uncontrollable issues encountered during this project were related to the economy and the budget cutbacks required during the project duration, which resulted in fewer bus drivers than expected the ultimate shut down of the City’s downtown bus operations.

08 HYDROGEN↗

Power Electronics Materials and Bonded Interfaces - Reliability and Lifetime

The emergence of wide-bandgap (WBG) devices in power electronics packages has brought significant attention to the reliability and thermal performance of the bonded interfaces. These interfaces, such as die-attach and substrate-attach, need to withstand the severe stress induced on them by the high-temperature (> 200°C) operation of the WBG devices. Sintered silver and transient liquid phase alloys are key bonded interfaces that can enable the high-temperature operation of WBG devices, however it is essential to evaluate their reliability and study the possible failure mechanisms before they can be used in power electronics packages. Sintered silver is already being adopted in commercial packages as a die-attach, but large-area substrate-attach offers additional reliability challenges. In this project, we investigate the reliability of these interface materials under accelerated thermal cycling and correlate these results with finite element simulations to develop lifetime prediction models. The failure mechanisms of these bonded interfaces are also studied.

47 OTHER INSTRUMENTATION↗

Reliability analysis of the F-8 digital fly-by-wire system

The F-8 Digital Fly-by-Wire (DFBW) flight test program intended to provide the technology for advanced control systems, giving aircraft enhanced performance and operational capability is addressed. A detailed analysis of the experimental system was performed to estimated the probabilities of two significant safety critical events: (1) loss of primary flight control function, causing reversion to the analog bypass system; and (2) loss of the aircraft due to failure of the electronic flight control system. The analysis covers appraisal of risks due to random equipment failure, generic faults in design of the system or its software, and induced failure due to external events. A unique diagrammatic technique was developed which details the combinatorial reliability equations for the entire system, promotes understanding of system failure characteristics, and identifies the most likely failure modes. The technique provides a systematic method of applying basic probability equations and is augmented by a computer program written in a modular fashion that duplicates the structure of these equations.

Brock, L. D.↗

Efficiency and Reliability Analyses of AC and 380V DC Distribution in Data Centers

Modern data centers consume large amounts of electricity, resulting in high operational costs. The efficiency of a data center power distribution system can be increased, and the operational cost reduced, if the number of power conversion stages can be minimized and more efficient converters, such as wide bandgap (WBG) converters, are used. This can be achieved by using DC distribution voltage at the rack level by eliminating extra conversion stages. In this paper, benchmarks for both AC and 380V DC data centers were developed and efficiency analyses were performed for an entire year. The impact of integrating photovoltaic (PV) systems into the data centers has also been analyzed in both cases in terms of efficiency. The results show that 380V DC data centers are more efficient than AC data centers with and without PV integration. Furthermore, the reliability of an AC system was compared to a 380V DC architecture with Tier-IV standard. Monte-Carlo simulations were used to perform reliability analyses for different levels of redundancy in the Uninterruptible Power Supply (UPS) system for both cases. In conclusion, the simulation results showed that the 380V DC distribution system had a higher level of reliability than the AC distribution system in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual–Interface–Reinforced Flexible Perovskite Solar Cells for Enhanced Performance and Mechanical Reliability

Two key interfaces in flexible perovskite solar cells (f-PSCs) are mechanically reinforced simultaneously: one between the electron-transport layer (ETL) and the 3D metal-halide perovskite (MHP) thin film using self-assembled monolayer (SAM), and the other between the 3D-MHP thin film and the hole-transport layer (HTL) using an in situ grown low-dimensional (LD) MHP capping layer. The interfacial mechanical properties are measured and modeled. This rational interface engineering results in the enhancement of not only the mechanical properties of both interfaces but also their optoelectronic properties holistically. As a result, the new class of dual-interface-reinforced f-PSCs has an unprecedented combination of the following three important performance parameters: high power-conversion efficiency (PCE) of 21.03% (with reduced hysteresis), improved operational stability of 1000 h T90 (duration at 90% initial PCE retained), and enhanced mechanical reliability of 10 000 cycles n88 (number of bending cycles at 88% initial PCE retained). Furthermore, the scientific underpinnings of these synergistic enhancements are elucidated.

14 SOLAR ENERGY↗

Solid Lubricants and Coatings for Extreme Environments: State-of-the-Art Survey

An investigation was conducted to survey anticipated requirements for solid lubricants in lunar and Martian environments, as well as the effects of these environments on lubricants and their performance and durability. The success of habitats and vehicles on the Moon and Mars, and ultimately, of the human exploration of and permanent human presence on the Moon and Mars, are critically dependent on the correct and reliable operation of many moving mechanical assemblies and tribological components. The coefficient of friction and lifetime of any lubricant generally vary with the environment, and lubricants have very different characteristics under different conditions. It is essential, therefore, to select the right lubrication technique and lubricant for each mechanical and tribological application. Several environmental factors are hazardous to performance integrity on the Moon and Mars. Potential threats common to both the Moon and Mars are low ambient temperatures, wide daily temperature swings (thermal cycling), solar flux, cosmic radiation, and large quantities of dust. The surface of Mars has the additional challenges of dust storms, winds, and a carbon dioxide atmosphere. Solid lubricants and coatings are needed for lunar and Martian applications, where liquid lubricants are ineffective and undesirable, and these lubricants must perform well in the extreme environments of the Moon, Mars, and space, as well as on Earth, where they will be assembled and tested. No solid lubricants and coatings and their systems currently exist or have been validated that meet these requirements, so new solid lubricants must be designed and validated for these applications.

Miyoshi, Kazuhisa↗

Structural Deterministic Safety Factors Selection Criteria and Verification

Though current deterministic safety factors are arbitrarily and unaccountably specified, its ratio is rooted in resistive and applied stress probability distributions. This study approached the deterministic method from a probabilistic concept leading to a more systematic and coherent philosophy and criterion for designing more uniform and reliable high-performance structures. The deterministic method was noted to consist of three safety factors: a standard deviation multiplier of the applied stress distribution; a K-factor for the A- or B-basis material ultimate stress; and the conventional safety factor to ensure that the applied stress does not operate in the inelastic zone of metallic materials. The conventional safety factor is specifically defined as the ratio of ultimate-to-yield stresses. A deterministic safety index of the combined safety factors was derived from which the corresponding reliability proved the deterministic method is not reliability sensitive. The bases for selecting safety factors are presented and verification requirements are discussed. The suggested deterministic approach is applicable to all NASA, DOD, and commercial high-performance structures under static stresses.

Verderaime, V.↗

Overview of Wendelstein 7-X high-performance operation

The Wendelstein 7-X (W7-X) stellarator has completed two consecutive experimental campaigns OP 2.2 (Sep.-Dec. 2024) and OP 2.3 (Feb.-May 2025) under a new operational strategy enabling more than one year of uninterrupted device availability. This approach, supported by exceptionally high subsystem reliability, allowed sustained high-efficiency plasma operations with up to 80–100 discharges per day across a broad range of magnetic configurations. Several key technical upgrades-most notably the first operation of a 1.5 MW class steady-state gyrotron, a new steady-state pellet injector, and advanced real-time feedback control systems significantly enhanced heating, fueling, and plasma control capabilities. Together, these improvements enabled major advances in long-pulse performance, high-β operation, and confinement optimization. Long-pulse discharges achieved 1.8 GJ of injected energy under fully detached divertor conditions, while reduced-field scenarios facilitated record volume-averaged β values approaching 3%. High-performance plasmas with centrally peaked density profiles, created via neutral beam injection (NBI) or sustained pellet fueling, demonstrated strongly reduced turbulent transport and stellarator-record fusion triple products. Complementary studies of power exhaust and divertor heat loads revealed the role of scrape-off-layer drift physics in shaping strike-line patterns under attached conditions. Together, the results from OP 2.2 and OP 2.3 significantly expand the operational space of W7-X and strengthen its role as a leading platform for steady-state stellarator research and reactor-relevant plasma scenarios.

Wendelstein 7-X↗

DSN Wide Area Network Architecture, Capacity and Performance

This paper discusses the architecture of the wide area network that connects key communications facilities within the National Aeronautic and Space Administration (NASA) Deep Space Network (DSN). Several considerations are given to the design of this wide area network to ensure a timely, reliable, and secure data delivery between the mission users and their spacecraft. The network star configuration simplifies data delivery to users and minimizes operational cost. The dual-path connections maximize the system reliability, with geographical diversity in data routing to avoid single point of failure. Data encryption enhances the protection of mission users’ data. The system bandwidth is determined by balancing the needs to minimize the operating bandwidth cost and to have sufficient bandwidth to be able to deliver data to all users within the required. The DSN uses a class base weighted fair queuing (CBWFQ) method in its data delivery. This scheme guarantees a minimum bandwidth to each class of users and allows users to also access any unused bandwidth by other groups. The paper will also show performance of system reliability and bandwidth margin.

Liao, Jason↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of Microgrid Algorithms using At-Scale Simulation and Emulation Real-Time (ASSERT) Framework

This paper presents a novel framework for validating microgrid algorithms using a At-Scale Simulation and Emulation Real-Time (ASSERT) setup. The proposed universal microgrid validation framework was developed at Advanced Research on Integrated Energy Systems (ARIES) platform at National Renewable Energy Laboratory in Golden, Colorado, USA. As the number of intercommunicating devices grow in power systems, along with more integration of inverter-based resources, developing and validating microgrid operation and control algorithms is becoming complex and time-consuming task. The ASSERT framework is designed to provide a comprehensive, accurate, and efficient solution for validating microgrid algorithms. It combines at-scale simulations and real-time emulation to create a virtual environment that closely mimics the behavior of a physical microgrids which are characteristic of future smart distribution systems, such as: (1) increasing variability in the physical size of new energy technologies; (2) requiring control large numbers of interconnected devices, and (3) integrating diverse technologies that have not previously worked together. The paper describes the technical details of the ASSERT framework, its validation process, and its benefits over traditional validation methods. The framework's ability to validate the performance of various algorithms is demonstrated through a case study, which shows that it can effectively identify the weaknesses of an algorithm and optimize its performance. Overall, the ASSERT framework is a promising tool that can significantly enhance the development and validation of microgrid algorithms, leading to more reliable and efficient microgrid operation.

at-scale↗

Data Analysis

Analysis of the material protection, control, and accountability (MPC&A) system is necessary to understand the limits and vulnerabilities of the system to internal threats. A self-appraisal helps the facility be prepared to respond to internal threats and reduce the risk of theft or diversion of nuclear material. The material control and accountability (MC&A) system effectiveness tool (MSET) fault tree was developed to depict the failure of the MPC&A system as a result of poor practices and random failures in the MC&A system. It can also be employed as a basis for assessing deliberate threats against a facility. MSET uses fault tree analysis, which is a top-down approach to examining system failure. The analysis starts with identifying a potential undesirable event called a 'top event' and then determining the ways it can occur (e.g., 'Fail To Maintain Nuclear Materials Under The Purview Of The MC&A System'). The analysis proceeds by determining how the top event can be caused by individual or combined lower level faults or failures. These faults, which are the causes of the top event, are 'connected' through logic gates. The MSET model uses AND-gates and OR-gates and propagates the effect of event failure using Boolean algebra. To enable the fault tree analysis calculations, the basic events in the fault tree are populated with probability risk values derived by conversion of questionnaire data to numeric values. The basic events are treated as independent variables. This assumption affects the Boolean algebraic calculations used to calculate results. All the necessary calculations are built into the fault tree codes, but it is often useful to estimate the probabilities manually as a check on code functioning. The probability of failure of a given basic event is the probability that the basic event primary question fails to meet the performance metric for that question. The failure probability is related to how well the facility performs the task identified in that basic event over time (not just one performance or exercise). Fault tree calculations provide a failure probability for the top event in the fault tree. The basic fault tree calculations establish a baseline relative risk value for the system. This probability depicts relative risk, not absolute risk. Subsequent calculations are made to evaluate the change in relative risk that would occur if system performance is improved or degraded. During the development effort of MSET, the fault tree analysis program used was SAPHIRE. SAPHIRE is an acronym for 'Systems Analysis Programs for Hands-on Integrated Reliability Evaluations.' Version 1 of the SAPHIRE code was sponsored by the Nuclear Regulatory Commission in 1987 as an innovative way to draw, edit, and analyze graphical fault trees primarily for safe operation of nuclear power reactors. When the fault tree calculations are performed, the fault tree analysis program will produce several reports that can be used to analyze the MPC&A system. SAPHIRE produces reports showing risk importance factors for all basic events in the operational MC&A system. The risk importance information is used to examine the potential impacts when performance of certain basic events increases or decreases. The initial results produced by the SAPHIRE program are considered relative risk values. None of the results can be interpreted as absolute risk values since the basic event probability values represent estimates of risk associated with the performance of MPC&A tasks throughout the material balance area (MBA). The RRR for a basic event represents the decrease in total system risk that would result from improvement of that one event to a perfect performance level. Improvement of the basic event with the greatest RRR value produces a greater decrease in total system risk than improvement of any other basic event. Basic events with the greatest potential for system risk reduction are assigned performance improvement values, and new fault tree calculations show the improvement in total system risk. The operational impact or cost-effectiveness from implementing the performance improvements can then be evaluated. The improvements being evaluated can be system performance improvements, or they can be potential, or actual, upgrades to the system. The RIR for a basic event represents the increase in total system risk that would result from failure of that one event. Failure of the basic event with the greatest RIR value produces a greater increase in total system risk than failure of any other basic event. Basic events with the greatest potential for system risk increase are assigned failure performance values, and new fault tree calculations show the increase in total system risk. This evaluation shows the importance of preventing performance degradation of the basic events. SAPHIRE identifies combinations of basic events where concurrent failure of the events results in failure of the top event.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluating Wind Direction Consensus Methods: A Case Study

Wind turbines in a wind farm typically operate individually to maximize their own performance and do not take into account information from nearby turbines. To enable cooperation to achieve farm-level objectives, turbines will need to use information from nearby turbines to optimize performance, ensure resiliency when other sensors fail, and adapt to changing local conditions. A key element of achieving these cooperative wind farms is to develop algorithms that provide necessary information to ensure reliable and efficient operation of turbines in a wind plant using local sensor information that is already being collected, such as supervisory control and data acquisition (SCADA) data, local meteorological stations, and nearby radars/sodars/lidars. This presentation demonstrates a framework for implementing a cooperative wind. Farm that incorporates information from local sensors in real time to better align turbines in a wind farm. Oftentimes, measurements made at an individual turbine are noisy and unreliable. By incorporating measurements from multiple nearby turbines, a more reliable estimate of the wind direction can be obtained at an individual turbine. Results indicate that this estimate of the wind direction can be used to improve the turbine's knowledge of the wind direction and could decrease dynamic yaw misalignment, decrease the amount of time a turbines spends yawing due to a more reliable input to the yaw controller, and increase resiliency to faulty wind-vane measurements. The concept was evaluated on data provided by WindESCo and was evaluated across several other averaging techniques to demonstrate the resiliency of the proposed consensus method.

17 WIND ENERGY↗