Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiator Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

HYPERON MATTER AND BLACK HOLE FORMATION IN FAILED SUPERNOVAE

We investigate the emergence of hyperons in black-hole-forming failed supernovae, which are caused by the dynamical collapse of nonrotating massive stars. We perform neutrino-radiation hydrodynamical simulations in general relativity, adopting realistic hyperonic equation of state. Attractive and repulsive cases are examined for the potential of {Sigma} hyperons. Since hyperons soften the EOS, they shorten the time interval from bounce to black hole formation, which corresponds to the duration of neutrino emission. This effect is more pronounced in the attractive case than in the repulsive case because {Sigma} hyperons appear more easily. In addition, we investigate the impacts of pions to find that they also promote recollapse toward black hole formation.

79 ASTRONOMY AND ASTROPHYSICS↗

FAR-ULTRAVIOLET OBSERVATIONS OF THE SPICA NEBULA AND THE INTERACTION ZONE

We report the analysis results of far-ultraviolet (FUV) observations, made for a broad region around {alpha} Vir (Spica) including the interaction zone of Loop I and the Local Bubble. The whole region was optically thin and a general correlation was seen between the FUV continuum intensity and the dust extinction, except in the neighborhood of the bright central star, indicating the dust scattering nature of the FUV continuum. We performed Monte Carlo radiative transfer simulations to obtain the optical parameters related to the dust scattering as well as to the geometrical structure of the region. The albedo and asymmetry factor were found to be 0.38 {+-} 0.06 and 0.46 {+-} 0.06, respectively, in good agreement with the Milky Way dust grain models. The distance to and the thickness of the interaction zone were estimated to be 70{sup +4}{sub -8} pc and 40{sup +8}{sub -10} pc, respectively. The diffuse FUV continuum in the northern region above Spica was mostly the result of scattering of the starlight from Spica, while that in the southern region was mainly due to the background stars. The C IV {lambda}{lambda}1548, 1551 emission was found throughout the whole region, in contrast to the Si II* {lambda}1532 emission which was bright only within the H II region. This indicates that the C IV line arises mostly at the shell boundaries of the bubbles, with a larger portion likely from the Loop I than from the Local Bubble side, whereas the Si II* line is from the photoionized Spica Nebula.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THE SPATIAL SCALES OF WAVE HEATING IN THE SOLAR CHROMOSPHERE

Dissipation of magnetohydrodynamic (MHD) wave energy has been proposed as a viable heating mechanism in the solar chromospheric plasma. Here, we use a simplified one-dimensional model of the chromosphere to theoretically investigate the physical processes and spatial scales that are required for the efficient dissipation of Alfvén waves and slow magnetoacoustic waves. We consider the governing equations for a partially ionized hydrogen-helium plasma in the single-fluid MHD approximation and include realistic wave damping mechanisms that may operate in the chromosphere, namely, Ohmic and ambipolar magnetic diffusion, viscosity, thermal conduction, and radiative losses. We perform an analytic local study in the limit of small amplitudes to approximately derive the lengthscales for critical damping and efficient dissipation of MHD wave energy. We find that the critical dissipation lengthscale for Alfvén waves depends strongly on the magnetic field strength and ranges from 10 m to 1 km for realistic field strengths. The damping of Alfvén waves is dominated by Ohmic diffusion for weak magnetic field and low heights in the chromosphere, and by ambipolar diffusion for strong magnetic field and medium/large heights in the chromosphere. Conversely, the damping of slow magnetoacoustic waves is less efficient, and spatial scales shorter than 10 m are required for critical damping. Thermal conduction and viscosity govern the damping of slow magnetoacoustic waves and play an equally important role at all heights. These results indicate that the spatial scales at which strong wave heating may work in the chromosphere are currently unresolved by observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Turbulent drifts of impurity ions as an explanation for anomalous radial transport in the far-SOL of DIII-D

Abstract Successful fusion reactor operation relies on minimal core contamination by impurities, otherwise too much power may be radiated and harm performance. This requires reliable predictions of impurity transport from the scrape-off layer (SOL) into the core, beyond the traditional ‘anomalous’ diffusion approach. We report a set of far-SOL tungsten transport simulations that demonstrate the role of turbulent drifts on radial impurity transport. A turbulent plasma background is simulated using the gyrokinetic SOL code Gkeyll. Tungsten ions are followed within the plasma background using only their drifts. We find that tungsten tends to travel radially outwards with velocities between v r = 300–1200 m s −1 primarily due to polarization drift. We also extract an anomalous radial diffusion coefficient that varies from D r anom = 5–20 m 2 s −1 . These results are compared to and agree with previous interpretive modeling results. We also show how the turbulent polarization drift can transport some tungsten ions from the wall inwards with effective pinch velocities up to 10 000 m s −1 . We conclude that turbulent drifts are a likely explanation for historically anomalous radial impurity transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam characterization at NSRL for radiobiological experiments—phase 1

An experimental campaign was carried out at the NASA Space Radiation Laboratory to perform an additional, independent dosimetric characterization of the beams of protons, helium and carbon ions for radiobiological experiments. The campaign was undertaken by the request and with the support from the National Cancer Institute, U.S. In this initial phase, the goals were to obtain a first assessment of the dosimetric reproducibility of the beam control system, including analysis of spatial homogeneity and evaluation of ion beam contamination. They should facilitate the design of further experimental campaigns for beam characterization for radiobiological experiments. Measurements included reference dosimetry with comparison of in-house and external ionization chambers and electrometers, lateral-dose profile measurements in air, depth-dose profile in a water tank, evaluation of water equivalent thickness of a HDPE binary range shifter and estimation of impurities of the investigated helium-ion beam. The experiments and results are presented.

43 PARTICLE ACCELERATORS↗

The straw tracking detector for the Fermilab Muon g-2 Experiment

The Muon g-2 Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of (110 ± 20) μm, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation and laboratory test results of 3D CMS pixel detectors for HL-LHC

The CMS pixel detector is the innermost tracking device at the LHC, reconstructing interaction vertices and charged particle trajectories. The current planar sensors located in the innermost layer of the pixel detector will be exposed to very high fluences which will degrade their performances. As a possible replacement for planar pixel sensors in the High Luminosity-LHC (HL-LHC), 3D silicon technology is under consideration due to its expected good performance in harsh radiation environments. Studies are also in progress for using 3D silicon pixel detectors in near-beam proton spectrometers at the LHC. Deep Reactive Ion Etching (DRIE) plays a key role in fabricating 3D silicon detectors in which readout and ohmic electrodes are processed through the silicon substrate instead of being implanted on the silicon surface. 3D pixel devices considered in this study were processed at FBK (Trento, Italy), bump bonded to the CMS pixel readout chip, and characterized in the laboratory. Numerical simulations were also carried out. We report on selected results from laboratory measurements and TCAD simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic dipole transitions in 4d{sup N} configurations of tungsten ions

Magnetic dipole transitions between the levels of ground 4d{sup N} configurations of tungsten ions were analyzed by employing a large basis of interacting configurations. Previously introduced configuration interaction strength between two configurations was used to determine the configurations with the largest contribution to wave functions of atomic states for the considered configurations. Collisional-radiative modeling was performed for the levels of the ground configuration coupled through electric dipole transitions with 4p{sup 5}4d{sup N+1} and 4d{sup N-1}4f configurations. New identification of some lines observed in the electron-beam ion trap plasma was proposed based on calculations in which wavelength convergence was reached.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search for η c ( 2 S ) → p p ¯ K + K − and measurement of χ c J → p p ¯ K + K − in ψ ( 3686 ) radiative decays

A search for η c ( 2 S ) → p p ¯ K + K − , together with measurement of branching fractions of χ c J ( J = 0 , 1 , 2 ) → p p ¯ K + K − in the ψ ( 3686 ) → γ η c ( 2 S ) and the ψ ( 3686 ) → γ χ c J radiative decays, is performed with ( 2712.4 ± 14.3 ) × 10 6 ψ ( 3686 ) events collected with the BESIII detector at the BEPCII collider. An evidence for η c ( 2 S ) → p p ¯ K + K − is found, with a significance of 3.3 σ . The product branching fraction of B [ ψ ( 3686 ) → γ η c ( 2 S ) ] · B [ η c ( 2 S ) → p p ¯ K + K − ] is determined to be ( 1.98 ± 0.4 1 stat ± 0.9 9 syst ) × 10 − 7 . The product branching fractions of B [ ψ ( 3686 ) → γ χ c J ] · B [ χ c J → p p ¯ K + K − ] are measured to be ( 2.49 ± 0.0 3 stat ± 0.1 5 syst ) × 10 − 5 , ( 1.83 ± 0.0 2 stat ± 0.1 1 syst ) × 10 − 5 , and ( 2.43 ± 0.0 2 stat ± 0.1 5 syst ) × 10 − 5 , for J = 0 , 1, and 2, respectively. Published by the American Physical Society 2025

Ablikim, M.↗

Cryogenic optical beam steering for superconducting device calibration

We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $μ$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation and optimization of the NSLS-II SRX beamline combining ray-tracing and wavefront propagation

The Sub-micron Resolution X-ray spectroscopy (SRX) beamline will benefit from the ultralow emittance of the National Synchrotron Light Source II to address a wide variety of scientific applications studying heterogeneous systems at the sub-micrometer scale. This work focuses on the KB branch ({Delta}E: 4.65-28 keV). Its main optical components include a horizontally focusing mirror forming an adjustable secondary source, a horizontally deflecting monochromator and two sets of Kirkpatrick-Baez mirrors as focusing optics of two distinct inline stations for operations requiring either high flux or high resolution. In the first approach, the beamline layout was optimized with ray-tracing calculations involving Shadowvui computer codes. As a result, the location and characteristics of optics were specified for achieving either the most intense or the smallest monochromatic beam possible on the target (10{sup 13} ph/s or 10{sup 12} ph/s respectively in a 500 nm or 65 nm focal spot). At the nanoprobe station, the diffraction limited focusing of X-rays is governed by the beam coherence. Hence, a classical geometric approach is not anymore adapted. To get reliable estimates of the Nanoprobe performances, a wavefront propagation study was performed using Synchrotron Radiation Workshop (SRW) code. At 7.2 keV, calculations show an intense (10{sup 12} ph/s) 67 nm wide diffraction limited spot achieved with actual metrological data of mirrors.

43 PARTICLE ACCELERATORS↗

Investigation of statistical iterative reconstruction for dedicated breast CT

Purpose: Dedicated breast CT has great potential for improving the detection and diagnosis of breast cancer. Statistical iterative reconstruction (SIR) in dedicated breast CT is a promising alternative to traditional filtered backprojection (FBP). One of the difficulties in using SIR is the presence of free parameters in the algorithm that control the appearance of the resulting image. These parameters require tuning in order to achieve high quality reconstructions. In this study, the authors investigated the penalized maximum likelihood (PML) method with two commonly used types of roughness penalty functions: hyperbolic potential and anisotropic total variation (TV) norm. Reconstructed images were compared with images obtained using standard FBP. Optimal parameters for PML with the hyperbolic prior are reported for the task of detecting microcalcifications embedded in breast tissue.Methods: Computer simulations were used to acquire projections in a half-cone beam geometry. The modeled setup describes a realistic breast CT benchtop system, with an x-ray spectra produced by a point source and an a-Si, CsI:Tl flat-panel detector. A voxelized anthropomorphic breast phantom with 280 μm microcalcification spheres embedded in it was used to model attenuation properties of the uncompressed woman's breast in a pendant position. The reconstruction of 3D images was performed using the separable paraboloidal surrogates algorithm with ordered subsets. Task performance was assessed with the ideal observer detectability index to determine optimal PML parameters.Results: The authors' findings suggest that there is a preferred range of values of the roughness penalty weight and the edge preservation threshold in the penalized objective function with the hyperbolic potential, which resulted in low noise images with high contrast microcalcifications preserved. In terms of numerical observer detectability index, the PML method with optimal parameters yielded substantially improved performance (by a factor of greater than 10) compared to FBP. The hyperbolic prior was also observed to be superior to the TV norm. A few of the best-performing parameter pairs for the PML method also demonstrated superior performance for various radiation doses. In fact, using PML with certain parameter values results in better images, acquired using 2 mGy dose, than FBP-reconstructed images acquired using 6 mGy dose.Conclusions: A range of optimal free parameters for the PML algorithm with hyperbolic and TV norm-based potentials is presented for the microcalcification detection task, in dedicated breast CT. The reported values can be used as starting values of the free parameters, when SIR techniques are used for image reconstruction. Significant improvement in image quality can be achieved by using PML with optimal combination of parameters, as compared to FBP. Importantly, these results suggest improved detection of microcalcifications can be obtained by using PML with lower radiation dose to the patient, than using FBP with higher dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-179: Prediction of Pelvic Nodal Coverage Using Mutual Information Between Cone-Beam and Planning CTs

Purpose: To investigate if pelvic nodal coverage for prostate patients undergoing intensity modulated radiotherapy (IMRT) can be predicted using mutual image information computed between planning and cone-beam CTs (CBCTs). Methods: Four patients with high-risk prostate adenocarcinoma were treated with IMRT on a Varian TrueBeam. Plans were designed such that 95% of the nodal planning target volume (PTV) received the prescription dose of 45 Gy (N=1) or 50.4 Gy (N=3). Weekly CBCTs (N=25) were acquired and the nodal clinical target volumes and organs at risk were contoured by a physician. The percent nodal volume receiving prescription dose was recorded as a ground truth. Using the recorded shifts performed by the radiation therapists at the time of image acquisition, CBCTs were aligned with the planning kVCT. Mutual image information (MI) was calculated between the CBCT and the aligned planning CT within the contour of the nodal PTV. Due to variable CBCT fields-of-view, CBCT images covering less than 90% of the nodal volume were excluded from the analysis, resulting in the removal of eight CBCTs. Results: A correlation coefficient of 0.40 was observed between the MI metric and the percent of the nodal target volume receiving the prescription dose. One patient's CBCTs had clear outliers from the rest of the patients. Upon further investigation, we discovered image artifacts that were present only in that patient's images. When those four images were excluded, the correlation improved to 0.81. Conclusion: This pilot study shows the potential of predicting pelvic nodal dosimetry by computing the mutual image information between planning CTs and patient setup CBCTs. Importantly, this technique does not involve manual or automatic contouring of the CBCT images. Additional patients and more robust exclusion criteria will help validate our findings.

60 APPLIED LIFE SCIENCES↗

SU-E-P-46: Clinical Acceptance Testing and Implementation of a Portable CT Unit

Purpose: Planning for the first installation in New England of a new portable CT unit to be used in the Operating Room required the integration of many departments including Surgery, Neurosurgery, Information Services, Clinical Engineering, Radiology and Medical Physics/Radiation Safety. Acceptance testing and the quality assurance procedures were designed to optimize image quality and patient and personnel radiation exposure. Methods: The vendor’s protocols were tested using the CT Dosimetry phantoms. The system displayed the CTDIw instead of the CTDIvol while testing the unit. Radiation exposure was compared to existing CT scanners from installed CT units throughout the facility. Brainlab measures all 4 periphery slots on the CT Dosimetry phantom. The ACR measures only the superior slot for the periphery measurement. A comprehensive radiation survey was also performed for several locations. Results: The CTDIvol measurements were comparable for the following studies: brain, C-Spine, and sinuses. However, the mobile CT measurements were slightly higher than other CT units but within acceptable tolerance if measured using the ACR method.Based on scatter measurements, it was determined if any personnel were to stay in the OR Suite during image acquisition that the appropriate lead apron and thyroid shields had to be worn.In addition, to reduce unnecessary scatter, there were two mobile 6 foot wide shields (1/16″ lead equivalent) available to protect personnel in the room and adjacent areas. Conclusion: Intraoperative CT provides the physician new opportunities for evaluation of the progression of surgical resections and device placement at the cost of increasing the amount of trained personnel required to perform this procedure. It also brings with it challenges to keep the radiation exposure to the patients and staff within reasonable limits.

60 APPLIED LIFE SCIENCES↗

SU-F-T-169: A Periodic Quality Assurance Program for a Spot-Scanning Proton Treatment Facility

Purpose: To develop daily and monthly quality assurance (QA) programs in support of a new spot-scanning proton treatment facility using a combination of commercial and custom equipment and software. Emphasis was placed on efficiency and evaluation of key quality parameters. Methods: The daily QA program was developed to test output, spot size and position, proton beam energy, and image guidance using the Sun Nuclear Corporation rf-DQA™3 device and Atlas QA software. The program utilizes standard Atlas linear accelerator tests repurposed for proton measurements and a custom jig for indexing the device to the treatment couch. The monthly QA program was designed to test mechanical performance, image quality, radiation quality, isocenter coincidence, and safety features. Many of these tests are similar to linear accelerator QA counterparts, but many require customized test design and equipment. Coincidence of imaging, laser marker, mechanical, and radiation isocenters, for instance, is verified using a custom film-based device devised and manufactured at our facility. Proton spot size and position as a function of energy are verified using a custom spot pattern incident on film and analysis software developed in-house. More details concerning the equipment and software developed for monthly QA are included in the supporting document. Thresholds for daily and monthly tests were established via perturbation analysis, early experience, and/or proton system specifications and associated acceptance test results. Results: The periodic QA program described here has been in effect for approximately 9 months and has proven efficient and sensitive to sub-clinical variations in treatment delivery characteristics. Conclusion: Tools and professional guidelines for periodic proton system QA are not as well developed as their photon and electron counterparts. The program described here efficiently evaluates key quality parameters and, while specific to the needs of our facility, could be readily adapted to other proton centers.

60 APPLIED LIFE SCIENCES↗

Contribution of inverse gluon emission to QCD corrections to the Drell-Yan process for experiments at the large hadron collider (LHC)

The contributions of inverse gluon emission to the lowest order QCD corrections to the Drell-Yan process for future experiments at LHC are calculated. The use of fully differential cross sections makes it possible to apply readily the results of these calculations for experimental purposes (in correcting data from future experiments at LHC). It is shown analytically that the present results are independent of the quark mass. A numerical analysis of respective radiative effects is performed by means of the READY FORTRAN code with allowance for the experimental cuts used at the Compact Muon Solenoid (CMS) detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiative corrections: from medium to high energy experiments

Abstract Radiative corrections are crucial for modern high-precision physics experiments, and are an area of active research in the experimental and theoretical community. Here we provide an overview of the state of the field of radiative corrections with a focus on several topics: lepton–proton scattering, QED corrections in deep-inelastic scattering, and in radiative light-hadron decays. Particular emphasis is placed on the two-photon exchange, believed to be responsible for the proton form-factor discrepancy, and associated Monte-Carlo codes. We encourage the community to continue developing theoretical techniques to treat radiative corrections, and perform experimental tests of these corrections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AWARE: The Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment (AWARE) performed comprehensive meteorological and aerosol measurements and ground-based atmospheric remote sensing at two Antarctic stations using the most advanced instrumentation available. A suite of cloud research radars, lidars, spectral and broadband radiometers, aerosol chemical and microphysical sampling equipment, and meteorological instrumentation was deployed at McMurdo Station on Ross Island from December 2015 through December 2016. A smaller suite of radiometers and meteorological equipment, including radiosondes optimized for surface energy budget measurement, was deployed on the West Antarctic Ice Sheet between 4 December 2015 and 17 January 2016. AWARE provided Antarctic atmospheric data comparable to several well-instrumented high Arctic sites that have operated for many years and that reveal numerous contrasts with the Arctic in aerosol and cloud microphysical properties. These include persistent differences in liquid cloud occurrence, cloud height, and cloud thickness. Antarctic aerosol properties are also quite different from the Arctic in both seasonal cycle and composition, due to the continent’s isolation from lower latitudes by Southern Ocean storm tracks. Antarctic aerosol number and mass concentrations are not only non-negligible but perhaps play a more important role than previously recognized because of the higher sensitivities of clouds at the very low concentrations caused by the large-scale dynamical isolation. Antarctic aerosol chemical composition, particularly organic components, has implications for local cloud microphysics. The AWARE dataset, fully available online in the ARM Program data archive, offers numerous case studies for unique and rigorous evaluation of mixed-phase cloud parameterization in climate models.

54 ENVIRONMENTAL SCIENCES↗