Search NASA⌕ Search

SEARCH · Search NASA

Results for “Real Time Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

The spectral basis of optimal error field correction on DIII-D

Here, experimental optimum error field correction (EFC) currents found in a wide breadth of dedicated experiments on DIII-D are shown to be consistent with the currents required to null the poloidal harmonics of the vacuum field which drive the kink mode near the plasma edge. This allows the identification of empirical metrics which predict optimal EFC currents with accuracy comparable to that of first- principles modeling which includes the ideal plasma response. While further metric refinements are desirable, this work suggests optimal EFC currents can be effectively fed-forward based purely on knowledge of the vacuum error field and basic equilibrium properties which are routinely calculated in real-time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control of hydrogen content and fuel recycling for long pulse high performance plasma operation in EAST

Control of fuel recycling and hydrogen content in the Experimental Advanced Superconducting Tokamak (EAST) using various methods is studied for high-power long pulse high confinement mode (H-mode) plasma operation. The results show that long duration first wall baking and discharge cleaning in EAST provides the necessary clean vacuum environment with a high ultimate vacuum of 3.6 × 10 -6 Pa and low outgassing rate of ~1.5 × 10 -4 Pa m 3 s -1 for plasma operation. In-vessel cryopumps are found to provide an efficient method for particle recycling control in the divertor region to decrease global recycling coefficient (R global ) from ~1.0 to ~0.8 during ohmic heating plasmas, and it provides a high particle exhausting rate of 10 20_ 10 21 D-atoms s -1 in high-power plasma operations. Long duration silicon coating is found to be more powerful than baking and discharge cleaning, which reduces the H/(H + D) ratio gradually to a value as low as 8%, and lithium coating is more effective and more efficient than silicon coating, to further reduce the H/(H + D) ratio to 3%. Real-time lithium powder injection is a novel method for recycling control, which reduces R global from 0.94 to 0.82 under lithium coating wall conditioning. By the combination and optimization of the above methods, H-mode plasmas with low hydrogen content and low fuel recycling have been achieved in EAST and have been extended gradually to 101 s in 2017. Recycling flux has even decreased gradually during 101 s H-mode plasmas due to increased first wall temperature and the resulting increased Li-II emission. These results provide valuable references on hydrogen content and fuel recycling control for long pulse H-mode plasmas of up to 400–1000 s with high-power heating in EAST and future fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Joint Estimation of Topology and Injection Statistics in Distribution Grids with Missing Nodes

Optimal operation of distribution grid resources relies on accurate estimation of its state and topology. Practical estimation of such quantities is complicated by the limited presence of real-time meters. This article discusses a theoretical framework to jointly estimate the operational topology and statistics of injections in radial distribution grids under limited availability of nodal voltage measurements. In particular, we show that our proposed algorithms are able to provably learn the exact grid topology and injection statistics at all unobserved nodes as long as they are not adjacent. The algorithm design is based on novel ordered trends in voltage magnitude fluctuations at node groups, that are independently of interest for radial physical flow networks. The complexity of the designed algorithms is theoretically analyzed and their performance is validated using both linearized and nonlinear ac power flow samples in test distribution grids.

97 MATHEMATICS AND COMPUTING↗

Battery Model Parameterization Using Manufacturer Datasheet and Field Measurement for Real-Time HIL Applications

Here, this paper presents a novel battery model parameterization method using actual field measurement and manufacturer datasheet for real-time hardware-in-the-loop (HIL) applications. It is critical that real-time HIL models can accurately reproduce field test results so that tests can be conducted on HIL testbeds instead of in the field. In the past, numerical heuristic optimization algorithms were often used to derive parameters for battery models. However, the deterministic algorithms often reach a locally optimal solution and stochastic heuristic searching strategies suffer from low searching efficiency. Therefore, in this paper, we propose a global-local searching enhanced genetic algorithm (GL-SEGA). By applying the generalized opposition-based learning mechanism, GL-SEGA can efficiently explore the global solution space. By using the trust-region-reflective method to perform the local search, the GL-SEGA can improve the accuracy and convergence in its local exploitations. Field measurements and manufactory datasheets are used to test and validate the accuracy and robustness of the GL-SEGA algorithm.

25 ENERGY STORAGE↗

Background Adaptive Radiation Detection (BARD) v1.0.0

The Background Adaptive Radiation Software can be deployed with static sensors in urban environments. It provides a real-time robust radiation detection based on a unique adaptive learning approach. Local radiation background models are automatically learnt for various environmental conditions, and monitored/re-trained, and selected over time for optimal radiation anomaly detection, informed by source templates directly derived from the data.

Abgrall, Nicolas↗

Recovery Act: Federspiel Controls (now Vigilent) and State of California Department of General Services Data Center Energy Efficient Cooling Control Demonstration. Final technical project report

Eight State of California data centers were equipped with an intelligent energy management system to evaluate the effectiveness, energy savings, dollar savings and benefits that arise when powerful artificial intelligence-based technology measures, monitors and actively controls cooling operations. Control software, wireless sensors and mesh networks were used at all sites. Most sites used variable frequency drives as well. The system dynamically adjusts temperature and airflow on the fly by analyzing real-time demands, thermal behavior and historical data collected on site. Taking into account the chaotic interrelationships of hundreds to thousands of variables in a data center, the system optimizes the temperature distribution across a facility while also intelligently balancing loads, outputs, and airflow. The overall project will provide a reduction in energy consumption of more than 2.3 million kWh each year, which translates to $240,000 saved and a reduction of 1.58 million pounds of carbon emissions. Across all sites, the cooling energy consumption was reduced by 41%. The average reduction in energy savings across all the sites that use VFDs is higher at 58%. Before this case study, all eight data centers ran the cooling fans at 100% capacity all of the time. Because of the new technology, cooling fans run at the optimum fan speed maintaining stable air equilibrium while also expending the least amount of electricity. With lower fan speeds, the life of the capital investment made on cooling equipment improves, and the cooling capacity of the data center increases. This case study depicts a rare technological feat: The same process and technology worked cost effectively in eight very different environments. The results show that savings were achieved in centers with diverse specifications for the sizes, ages and types of cooling equipment. The percentage of cooling energy reduction ranged from 19% to 78% while keeping temperatures substantially within the limits recommended by the American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) for data center facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intelligent Monitoring Systems and Advanced Well Integrity and Mitigation

Long-term seismic monitoring of carbon capture and storage projects is needed to verify that the injected gas is safely stored in the subsurface until permanence can be assured. Conventional surface seismic monitoring techniques are usually expensive, require highly invasive surface operations, and need significant time investments on the part of personnel for both the field effort and processing the acquired data. For these reasons, permanent reservoir monitoring technologies are preferred, as they can offer a cost-effective solution for long-term monitoring. As part of the monitoring program of the Archer Daniels Midland’s large-scale injection of CO 2 in Decatur, Illinois, USA, a continuous seismic monitoring array was installed using a combination of surface orbital vibrator (SOV) sources and fiber-optic cables for distributed acoustic sensing (DAS) acquisition with the objective to build a continuous monitoring array. The aim of the presented project was to build a monitoring array and platform that integrates real-time seismic data with conventional data streams and provides continuous data analysis using dynamic computational models to deliver a comprehensive real-time assessment of subsurface conditions. It is in this context that the Intelligent Monitoring Systems and Advanced Well Integrity and Mitigation project was proposed with the objective to develop an integrated architecture that utilizes a permanent seismic monitoring network, combines the real-time geophysical and process data with reservoir flow and geomechanical models to create a comprehensive monitoring, visualization, and control system that delivers critical information for process surveillance and optimization.

54 ENVIRONMENTAL SCIENCES↗

Computerized procedure systems: procedure edition and maintenance challenges - 232

Very few nuclear power plants are using computerized procedures to guide the control room operation. A CPS implementation consists of two processes: digitalization and computerization. The former deals with the transformation of paper-based procedure into a digital data; the latter is referred to as the addition to that data of extra information that is meaningful for decision-making. This information may include real-time data (plant parameter values and binary process values to indicate equipment states), provide access to trends and historical data, etc. In order to be efficient and to optimize the digitalization and computerization processes, these set of aids should be implemented at the same time as operating procedures are digitalized There are references of plants having successfully implemented Computerized Procedures Systems (CPS) for emergency procedures, but when questioned about normal or abnormal operating procedures, operators and plant management seem reluctant to take that step. Given that a CPS is meant, by design concept, to increase operation crew efficiency by facilitating the procedures execution and reducing human error, why are we reluctant to enjoy CPS benefits in the most common plant status (i.e. normal operation)? Although there are many answers to this question, one is shared by most of the users: CPSs are not designed for editing and maintaining procedures easily and reliably. Normal operating procedures, in opposition to the emergency procedures, are often reviewed. Nowadays, these edition activities are performed easily with a word processor software and using paper, but what is required when dealing with a CPS? (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization

Purpose: This paper reports on the design and initial imaging performance of a dedicated cone-beam CT (CBCT) system for musculoskeletal (MSK) extremities. The system complements conventional CT and MR and offers a variety of potential clinical and logistical advantages that are likely to be of benefit to diagnosis, treatment planning, and assessment of therapy response in MSK radiology, orthopaedic surgery, and rheumatology. Methods: The scanner design incorporated a host of clinical requirements (e.g., ability to scan the weight-bearing knee in a natural stance) and was guided by theoretical and experimental analysis of image quality and dose. Such criteria identified the following basic scanner components and system configuration: a flat-panel detector (FPD, Varian 3030+, 0.194 mm pixels); and a low-power, fixed anode x-ray source with 0.5 mm focal spot (SourceRay XRS-125-7K-P, 0.875 kW) mounted on a retractable C-arm allowing for two scanning orientations with the capability for side entry, viz. a standing configuration for imaging of weight-bearing lower extremities and a sitting configuration for imaging of tensioned upper extremity and unloaded lower extremity. Theoretical modeling employed cascaded systems analysis of modulation transfer function (MTF) and detective quantum efficiency (DQE) computed as a function of system geometry, kVp and filtration, dose, source power, etc. Physical experimentation utilized an imaging bench simulating the scanner geometry for verification of theoretical results and investigation of other factors, such as antiscatter grid selection and 3D image quality in phantom and cadaver, including qualitative comparison to conventional CT. Results: Theoretical modeling and benchtop experimentation confirmed the basic suitability of the FPD and x-ray source mentioned above. Clinical requirements combined with analysis of MTF and DQE yielded the following system geometry: a {approx}55 cm source-to-detector distance; 1.3 magnification; a 20 cm diameter bore (20 x 20 x 20 cm{sup 3} field of view); total acquisition arc of {approx}240 deg. The system MTF declines to 50% at {approx}1.3 mm{sup -1} and to 10% at {approx}2.7 mm{sup -1}, consistent with sub-millimeter spatial resolution. Analysis of DQE suggested a nominal technique of 90 kVp (+0.3 mm Cu added filtration) to provide high imaging performance from {approx}500 projections at less than {approx}0.5 kW power, implying {approx}6.4 mGy (0.064 mSv) for low-dose protocols and {approx}15 mGy (0.15 mSv) for high-quality protocols. The experimental studies show improved image uniformity and contrast-to-noise ratio (without increase in dose) through incorporation of a custom 10:1 GR antiscatter grid. Cadaver images demonstrate exquisite bone detail, visualization of articular morphology, and soft-tissue visibility comparable to diagnostic CT (10-20 HU contrast resolution). Conclusions: The results indicate that the proposed system will deliver volumetric images of the extremities with soft-tissue contrast resolution comparable to diagnostic CT and improved spatial resolution at potentially reduced dose. Cascaded systems analysis provided a useful basis for system design and optimization without costly repeated experimentation. A combined process of design specification, image quality analysis, clinical feedback, and revision yielded a prototype that is now awaiting clinical pilot studies. Potential advantages of the proposed system include reduced space and cost, imaging of load-bearing extremities, and combined volumetric imaging with real-time fluoroscopy and digital radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous quantification of uranium( VI ), samarium, nitric acid, and temperature with combined ensemble learning, laser fluorescence, and Raman scattering for real-time monitoring

In this work, laser-induced fluorescence spectroscopy (LIFS), Raman spectroscopy, and a stacked regression ensemble was developed for near real-time quantification of uranium(VI) (1–100 μg mL –1 ), samarium (0–200 μg mL –1 ) and nitric acid (0.1–4 M) with varying temperature (20 °C–45 °C). LIFS applications range from fundamental lab-scale studies to real-time process monitoring at industrial levels, such as nuclear reprocessing applications, provided the phenomena affecting the fluorescence spectrum are accounted for (e.g., absorption, quenching, complexation). Multiple chemometric models were examined and compared to a more traditional multivariate regression approach called partial least squares (PLS). Results obtained on synthetic samples selected using D-optimal experimental design indicated that a stacked regression method, which included ridge regression, random forest, PLS, and an eXtreme gradient boost algorithm, successfully measured uranium(VI) concentrations directly in nitric acid without measuring luminescence lifetimes or standard addition. The top model resulted in percent root-mean-square error of prediction values of 5.2, 1.9, 3.0, and 2.3% for U(VI), Sm 3+ , HNO 3 , and temperature, respectively. The approach may be useful for quantifying fluorescent fission products (e.g., Sm 3+ ) to provide information on burnup of irradiated nuclear fuel. This novel framework reinforces the applicability of LIFS for real-time applications in nuclear fuel cycle applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Estimating PV power from aggregate power measurements within the distribution grid

The increased integration of photovoltaic (PV) systems in distribution grids reduces visibility and situational awareness for utilities because the PV systems' power production is usually not monitored by them. To address this problem, a method called Contextually Supervised Source Separation (CSSS) has been recently adapted for real-time estimation of aggregate PV active power generation from aggregate net active and reactive power measurements at a point in a radially configured distribution grid (e.g., substation). In its original version, PV disaggregation is formulated as an optimization problem that fits linear regression models for the aggregate PV active power generation and true substation active power load. This paper extends the previous work by adding regularization terms in the objective function to capture additional contextual information such as smoothness, by adding new constraints, by introducing new regressors such as ambient temperature, and by investigating the use of time-varying regressors. Furthermore, we perform extensive parametric analysis to study tuning of the objective function weighting factors in a way that maximizes performance and robustness. The proposed PV disaggregation method can be applied to networks with either a single PV system (e.g., megawatt scale) or many distributed ones (e.g., residential scale) connected downstream of the substation. Simulation studies with real field recorded data show that the enhancements of the proposed method reduce disaggregation error by 58% in winter and 35% in summer compared to previous CSSS-based work. When compared against a commonly used transposition model based approach, the reduction in disaggregation error is more pronounced (78% reduction in winter and 45% in summer). Additional simulations indicate that the proposed algorithm is also applicable for PV systems with time-varying power factors. In conclusion, overall, our results show that—with appropriate modeling and tuning—it is possible to accurately estimate the aggregated PV active power generation of a distribution feeder with minimal or no additional sensor deployment.

14 SOLAR ENERGY↗

Instrumentation for Hanford Direct-Feed Low-Activity Waste Real-Time, In-Line Process Monitoring - 18339

The direct-feed low-activity waste (DFLAW) process will utilize facilities in the Hanford tank farms to stage tank waste feed, a new facility to pretreat the tank waste feed, and facilities in the Hanford Waste Treatment and Immobilization Plant (WTP) to immobilize the low-activity waste (LAW) and disposition effluents from the vitrification process. Process sampling is used extensively throughout the DFLAW process to qualify waste feeds, control the process, and demonstrate compliance with regulatory and contractual commitments. The U.S. Department of Energy's Office of River Protection (ORP) has started a program to evaluate the potential benefits of replacing some sample collection requirements with realtime, in-line monitoring (RTIM). The program will identify, develop, and evaluate technologies that can reduce the number of samples required for WTP operation. Potential benefits of RTIM include elimination of process holds for sample analysis, a reduction in worker exposure to radiation and chemical hazards, decreased secondary waste volume, reducing the cost for sample collection and analysis, an improvement in product quality, and timely indication of process anomalies. In order to incorporate RTIM, the process control strategy for the overall process, as well as each unit operation, was reviewed and revisions to the strategies proposed. The following items were identified for incorporation of RTIM: - Real-time material balance calculations linked to the process control system; - Use of RTIM instruments to validate the material balance for selected analytes; - Anion analysis for determination of selected semi-volatile species (e.g., chlorine, sulfur, and fluorine) in the recycle stream. Based on the proposed process control strategy, a preliminary list of potential analytical equipment was developed. This was followed by a preliminary survey of instrument technologies currently on the market building on surveys performed for ORP, literature reviews, vendor web sites, and subject matter experts from the Savannah River National Laboratory and other U.S. Department of Energy national laboratories. Each technology was evaluated for measurement capability, operations and maintenance requirements, space requirements, and potential for application as process control instrumentation. The instrument technologies were chosen based on the following criteria: - Ability to perform analyses needed; - Potential to be used or adapted for use as process control instruments; - Potential to be adapted to size and operational constraints of standard WTP sample cabinets; - Operational and maintenance requirements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In Situ Observation of Directed Nanoparticle Aggregation During the Synthesis of Ordered Nanoporous Metal in Soft Templates

The prevalent approach to developing new nanomaterials is a trial and error process of iteratively altering synthesis procedures and then characterizing the resulting nanostructures. This is fundamentally limited in that the growth processes that occur during synthesis can only be inferred from the final synthetic structure. Directly observing real-time nanomaterial growth provides unprecedented insight into the relationship between synthesis conditions and product evolution, and facilitates a mechanistic approach to nanomaterial development. Here we use in situ liquid stage scanning transmission electron microscopy to observe the growth of mesoporous palladium in a solvated block copolymer (BCP) template under various synthesis conditions, and ultimately determine a refined synthesis procedure that yields ordered pores. We find that at low organic solvent (tetrahydrofuran, THF) content, the BCP assembles into a rigid, cylindrical micelle array with a high degree of short-range order, but poor long-range order. Upon slowing the THF evaporation rate using a solvent-vapor anneal step, the long-range order is greatly improved. The electron beam induces nucleation of small particles in the aqueous phase around the micelles. The small particles then flocculate and grow into denser structures that surround the micelles, forming an ordered mesoporous structure. The microscope observations revealed that template disorder can be addressed prior to reaction, and is not invariably induced by the growth process itself, allowing us to more quickly optimize the synthetic method. This work was conducted in the William R. Wiley Environmental Molecular Sciences Laboratory (EMSL), a national scientific user facility sponsored by DOE’s Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory. The Pacific Northwest National Laboratory is operated by Battelle for the U.S. Department of Energy under contract DE-AC05-76RL01830. This research was funded in part by: the Presidential Early Career Award for Scientist and Engineers for I.A., the University of California Academic Senate and the University of California Laboratory fee research grant, the Laboratory-Directed Research and Development program at Sandia National Laboratories, and the Chemical Imaging Initiative at Pacific Northwest National Laboratory. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

cylindrical micelle↗

Tore Supra LH transmitter upgrade, a new RF driver for the power spectrum

New real time tools have been developed for testing new 700kW/3.7GHz/CW klystrons and for the operations on very long plasma shots. After the commissioning of the 18 series tubes on the high power test bed facility, the installation of the first 8 klystrons in the Tore Supra transmitter and the adjustment tests on load, this upgrade work has been materialized during the last 2010 campaign by a successful operation on the Full Active Multijunction (FAM) C3 antenna, with new performances: 3.5MW/40s on plasma. The RF output power control in amplitude and phase has been improved for a better control of the wave spectrum launched into the plasma. The new klystrons have no modulating anode and the high cathode voltage must be adjusted with the RF input power in order to optimize the RF output power with a minimization of the thermal power losses in the collector. A new phase correction, depending on the 3 RF output power ranges used, has been introduced. The improvements made in 2009 and 2010 on the generic phase loop and the procedures used during the real time tests of the RF transfer functions in amplitude and phase are detailed below. All RF measurements systems, RF safety systems and the RF calibration procedures have been revised in order to have the best consistency, reproducibility and with a measurement error against the calorimetry measurement lower than 10%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dispatch optimization of a concentrating solar power system under uncertain solar irradiance and energy prices

The integration of thermal energy storage into a concentrating solar power system allows for mitigating some of the risk associated with uncertain solar irradiance and uncertain energy prices. We solve a 48 h dispatch optimization model with continually updated conditional point forecasts of both direct normal irradiance (DNI) and electricity prices with a rolling-horizon scheme at hourly resolution over the course of a year. Joint, conditional forecasts for DNI and prices are formed using an autoregressive moving-average time series model with exogenous weather predictors. We guide dispatch using a mixed-integer programming model, but in order to evaluate performance we use the System Advisor Model (SAM) of the National Renewable Energy Laboratory. SAM is a techno-economic simulation model that accounts for plant thermodynamics with higher fidelity. Our conditional DNI forecasts improve annual revenue by 4%–12% over using historical forecasts based on data from previous years. Conditional price forecasts improve annual revenue by 6%–19% in the real-time market over analogous historical forecasts. Updating these forecasts every six hours, rather than every 24 h, further improves annual revenue by 5%–6%. Here, we also investigate a method that values terminal inventory in our dispatch optimization model, again when used in a rolling-horizon scheme.

14 SOLAR ENERGY↗

Dynamic Resource Scheduling in Mobile Edge Cloud with Cloud Radio Access Network

Nowadays, by integrating the cloud radio access network (C-RAN) with the mobile edge cloud computing (MEC) technology, mobile service provider (MSP) can efficiently handle the increasing mobile traffic and enhance the capabilities of mobile devices. But the power consumption has become skyrocketing for MSP and it gravely affects the profit of MSP. Previous work often studied the power consumption in C-RAN and MEC separately while less work had considered the integration of C-RAN with MEC. In this paper, we present an unifying framework for the power-performance tradeoff of MSP by jointly scheduling network resources in C-RAN and computation resources in MEC to maximize the profit of MSP. To achieve this objective, we formulate the resource scheduling issue as a stochastic problem and design a new optimization framework by using an extended Lyapunov technique. Specially, because the standard Lyapunov technique critically assumes that job requests have fixed lengths and can be finished within each decision making interval, it is not suitable for the dynamic situation where the mobile job requests have variable lengths. To solve this problem, we extend the standard Lyapunov technique and design the VariedLen algorithm to make online decisions in consecutive time for job requests with variable lengths. Furthermore, our proposed algorithm can reach time average profit that is close to the optimum with a diminishing gap (1/V) for the MSP while still maintaining strong system stability and low congestion. With extensive simulations based on a real world trace, we demonstrate the efficacy and optimality of our proposed algorithm.

97 MATHEMATICS AND COMPUTING↗

Wind direction estimation using SCADA data with consensus-based optimization

Abstract. Wind turbines in a wind farm typically operate individually to maximize their own performance and do not take into account information from nearby turbines. To enable cooperation to achieve farm-level objectives, turbines will need to use information from nearby turbines to optimize performance, ensure resiliency when other sensors fail, and adapt to changing local conditions. A key element of achieving a more efficient wind farm is to develop algorithms that ensure reliable, robust, real-time, and efficient operation of wind turbines in a wind farm using local sensor information that is already being collected, such as supervisory control and data acquisition (SCADA) data, local meteorological stations, and nearby radars/sodars/lidars. This article presents a framework for developing a cooperative wind farm that incorporates information from nearby turbines in real time to better align turbines in a wind farm. SCADA data from multiple turbines can be used to make better estimates of the local inflow conditions at each individual turbine. By incorporating measurements from multiple nearby turbines, a more reliable estimate of the wind direction can be obtained at an individual turbine. The consensus-based approach presented in this paper uses information from nearby turbines to estimate wind direction in an iterative way rather than aggregating all the data in a wind farm at once. Results indicate that this estimate of the wind direction can be used to improve the turbine's knowledge of the wind direction. This estimated wind direction signal has implications for potentially decreasing dynamic yaw misalignment, decreasing the amount of time a turbine spends yawing due to a more reliable input to the yaw controller, increasing resiliency to faulty wind-vane measurements, and increasing the potential for wind farm control strategies such as wake steering.

17 WIND ENERGY↗

Traffic Signal Control for Large-Scale Urban Traffic Networks: Real-World Experiments using Vision-Based Sensors

Effective control of traffic signals plays a critical role in ensuring smooth vehicle flow in urban areas. Expertly engineered traffic signal controllers can considerably minimize travel delays and enhance sustainability. In this paper, the team proposes the Model Predictive Control (MPC) traffic signal control strategy using real-time traffic flow data from a vision-based camera as feedback information. Also, a realistic signal timing plan that considers National Electrical Manufacturers Association (NEMA) constraints has been developed to be applied to real-world scenarios. The primary aim is to reduce the number of vehicles across all links in the controlled area, thereby optimizing traffic flow and reducing energy consumption. To validate the proposed method, several real-life experiments were conducted at 24 intersections in Chattanooga, Tennessee, by collaborating with traffic field engineers. These experiments demonstrated significant performance improvements in comparison to the existing method.

data processing↗