Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Innovations in ILC detector design using a particle flow algorithm approach.

The International Linear Collider (ILC) is a future e{sup +}e{sup -} collider that will produce particles with masses up to the design center-of-mass (CM) energy of 500 GeV. The ILC complements the Large Hadron Collider (LHC) which, although colliding protons at 14 TeV in the CM, will be luminosity-limited to particle production with masses up to {approx}1-2 TeV. At the ILC, interesting cross-sections are small, but there are no backgrounds from underlying events, so masses should be able to be measured by hadronic decays to dijets ({approx}80% BR) as well as in leptonic decay modes. The precise measurement of jets will require major detector innovations, in particular to the calorimeter, which will be optimized to reconstruct final state particle 4-vectors--called the particle flow algorithm approach to jet reconstruction.

43 PARTICLE ACCELERATORS↗

Poster – 02: Positron Emission Tomography (PET) Imaging Reconstruction using higher order Scattered Photon Coincidences

PET images are affected by the presence of scattered photons. Incorrect scatter-correction may cause artifacts, particularly in 3D PET systems. Current scatter reconstruction methods do not distinguish between single and higher order scattered photons. A dual-scattered reconstruction method (GDS-MLEM) that is independent of the number of Compton scattering interactions and less sensitive to the need for high energy resolution detectors, is proposed. To avoid overcorrecting for scattered coincidences, the attenuation coefficient was calculated by integrating the differential Klein-Nishina cross-section over a restricted energy range, accounting only for scattered photons that were not detected. The optimum image can be selected by choosing an energy threshold which is the upper energy limit for the calculation of the cross-section and the lower limit for scattered photons in the reconstruction. Data was simulated using the GATE platform. 500,000 multiple scattered photon coincidences with perfect energy resolution were reconstructed using various methods. The GDS-MLEM algorithm had the highest confidence (98%) in locating the annihilation position and was capable of reconstructing the two largest hot regions. 100,000 photon coincidences, with a scatter fraction of 40%, were used to test the energy resolution dependence of different algorithms. With a 350–650 keV energy window and the restricted attenuation correction model, the GDS-MLEM algorithm was able to improve contrast recovery and reduce the noise by 7.56%–13.24% and 12.4%–24.03%, respectively. This approach is less sensitive to the energy resolution and shows promise if detector energy resolutions of 12% can be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure of isolated biomolecules obtained from ultrashort x-ray pulses: exploiting the symmetry of random orientations

mongst the promised capabilities of fourth-generation x-ray sources currently under construction is the ability to record diffraction patterns from individual biological molecules. One version of such an experiment would involve directing a stream of molecules into the x-ray beam and sequentially recording the scattering from each molecule of a short, but intense, pulse of radiation. The pulses are sufficiently short that the diffraction pattern is that due to scattering from identical molecules frozen gorithms have been proposed for finding the relative orientations from just the measured diffraction data. The common-line method, also employed in 3D electron microscopy, appears not best suited to the very low mean photon count per diffraction pattern pixel expected in such experiments. A manifold embedding technique has been used to reconstruct the 3D diffraction volume and hence the electron density of a small protein at the signal level expected of the scattering of an x-ray free electron laser pulse from a 500 kD biomolecule. In this paper, we propose an alternative algorithm which raises the possibility of reconstructing the 3D diffraction volume of a molecule without determining the relative orientations of the individual diffraction patterns. We discuss why such an algorithm may provide a practical and computationally convenient method of extracting information from very weak diffraction patterns. We suggest also how such a method may be adapted to the problem of finding the variations of a structure with time in a time-resolved pump probe experiment.

36 MATERIALS SCIENCE↗

Identification of long-lived charged particles using time-of-flight systems at the upgraded LHC detectors

We study the impact of picosecond precision timing detection systems on the LHC experiments' long-lived particle search program during the HL-LHC era. We develop algorithms that allow us to reconstruct the mass of such charged particles and perform particle identification using the time-of-flight measurement. We investigate the reach for benchmark scenarios as a function of the timing resolution, and find sensitivity improvement of up to a factor of ten, depending on the new heavy particle mass.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-Dimensional Settling Dynamics of Environmental Microplastics

Resolving the three-dimensional settling dynamics of microplastic (MP) particles is essential for developing comprehensive models of MP transport in rivers-both vertically within the water column and laterally across the channel. While previous research has largely examined one-dimensional vertical settling velocities, little is known about the lateral drifting, settling paths, and horizontal velocities of MPs. To address this, we investigated the full three-dimensional settling behavior of environmental MPs collected from rivers and ocean water, as well as from estuarine and ocean sediment. Geometric properties of 127 environmental MPs were quantified by a dynamic particle image analyzer, and their settling trajectories were recorded and reconstructed via a multicamera tracking algorithm. This enabled quantification of a particle's horizontal drift, tortuosity, amplitude and settling pattern, as well as vertical and horizontal velocities. Results showed that spherical MPs settled with minimal lateral displacement, whereas elongated particles, such as rod- and blade-shaped MPs, displayed pronounced lateral movements, reaching up to 65 times their equivalent diameter and averaging more than twice that of spheres. These dynamics suggest that elongated MPs may have a greater probability for wider lateral dispersion in rivers, increasing their likelihood for interactions with riverbanks and channel boundaries compared to more spherical shaped MPs.

54 ENVIRONMENTAL SCIENCES↗

4D Imaging of ZnO-Coated Nanoporous Al 2 O 3 Aerogels by Chemically Sensitive Ptychographic Tomography: Implications for Designer Catalysts

The 3D chemical structure (4D spectromicroscopy) of nanoporous Al 2 O 3 aerogels coated with ZnO by atomic layer deposition (ALD) was studied by multienergy scanning transmission X-ray microscopy. These materials are representative of a class of designer catalysts in which the nanoporous support is prepared separately from the active catalyst material, which is subsequently introduced by ALD, thereby allowing independent optimization of the morphology, chemistry, and spatial distribution of the support and catalyst. The samples studied were prepared by Ga ion and Xe plasma focused ion beam (FIB) milling as well as drop casting from water suspension. Zn L and Al K edge spectra of six samples with three different ZnO loadings were measured to investigate how loading and different sample preparation methods affect the 3D distribution of the ZnO and Al 2 O 3 . Scanning transmission X-ray microscopy (STXM) and ptychographic imaging at two energies each at the Zn L 3 and Al K edge were measured. The ptychography data were analyzed by using the SHARP reconstruction code to generate quantitative 2D chemical maps of the Al 2 O 3 and the ZnO. The STXM and ptychography maps were then measured at a sequence of tilt angles, covering up to 160° of rotation. The 3D structure of the ZnO and Al 2 O 3 was derived from the tilt series data by tomographic reconstruction using a compressed sensing algorithm. A twodimensional spatial resolution (half-period) of 6 nm, measured by Fourier ring correlation, and a 3D spatial resolution (half-period) of 9 nm, measured by Fourier shell correlation, were achieved when using the COSMIC beamline at the Advanced Light Source (ALS). The results show that for all of the ZnO loadings studied there is nonuniform coverage of the ZnO on the Al 2 O 3 aerogel framework. In addition, we found that both FIB methods create sample artifacts, although the distortion was less with Xe plasma than Ga ion FIB.

36 MATERIALS SCIENCE↗

Diffraction data from aerosolized Coliphage PR772 virus particles imaged with the Linac Coherent Light Source

Single Particle Imaging (SPI) with intense coherent X-ray pulses from X-ray free-electron lasers (XFELs) has the potential to produce molecular structures without the need for crystallization or freezing. Here we present a dataset of 285,944 diffraction patterns from aerosolized Coliphage PR772 virus particles injected into the femtosecond X-ray pulses of the Linac Coherent Light Source (LCLS). Additional exposures with background information are also deposited. The diffraction data were collected at the Atomic, Molecular and Optical Science Instrument (AMO) of the LCLS in 4 experimental beam times during a period of four years. The photon energy was either 1.2 or 1.7 keV and the pulse energy was between 2 and 4 mJ in a focal spot of about 1.3 μm x 1.7 μm full width at half maximum (FWHM). The X-ray laser pulses captured the particles in random orientations. The data offer insight into aerosolised virus particles in the gas phase, contain information relevant to improving experimental parameters, and provide a basis for developing algorithms for image analysis and reconstruction.

59 BASIC BIOLOGICAL SCIENCES↗

Cylinders and jets in crossflow: Wake formations as a result of varying geometric proximities

The combined flow physics of several canonical flow configurations is experimentally studied. Here, we analyze an array of jets issuing into a crossflow, then immediately navigating past an array of cylinders. This is achieved with a 2 × 3 triangular pattern of jets and symmetric cylinders at three jets to crossflow velocity ratios, enabling near-complete optical access of each jet, with velocities measured by time-resolved particle image velocimetry. Jet trajectories reveal that each configuration adheres to a power-law trend and that greater penetration is achieved by the downstream and confined jets compared to the more conventional upstream one. Recirculation regions of the upstream and downstream jets are nearly independent, with the confined jet encompassing regions of overlap with both. Turbulent statistics reveal the influence of geometric placement and velocity ratio on the time-averaged velocity, anisotropy, and Reynolds stresses incurred by each jet. Galilean decomposition utilizes a supplemental crossflow-only velocity field to delineate the influence of each jet's low- and high-pressure regions on the otherwise uniform stream. Proper orthogonal decomposition suggests that increased jet penetration decreases the number of modes required for truncation in the investigated spanwise plane. Vortex identification algorithms are applied to the reconstructed flow fields, reaffirming that with increasing velocity ratio, the jets generate vortices of their own in similar statistical formations as the cylinders. This investigation provides a foundation to aid future modeling efforts toward characterizing flow physics of importance in designing and passively controlling transverse jets with varying blockage proximities in a crossflow.

Kristo, Paul J. (ORCID:0000000225605175)↗

Theoretical limit of spatial resolution in diffuse optical tomography using a perturbation model

We have assessed the limit of spatial resolution of timedomain diffuse optical tomography (DOT) based on a perturbation reconstruction model. From the viewpoint of the structure reconstruction accuracy, three different approaches to solving the inverse DOT problem are compared. The first approach involves reconstruction of diffuse tomograms from straight lines, the second – from average curvilinear trajectories of photons and the third – from total banana-shaped distributions of photon trajectories. In order to obtain estimates of resolution, we have derived analytical expressions for the point spread function and modulation transfer function, as well as have performed a numerical experiment on reconstruction of rectangular scattering objects with circular absorbing inhomogeneities. It is shown that in passing from reconstruction from straight lines to reconstruction using distributions of photon trajectories we can improve resolution by almost an order of magnitude and exceed the accuracy of reconstruction of multi-step algorithms used in DOT. (optical tomography)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE GALACTIC {sup 26}AL EMISSION MAP AS REVEALED BY INTEGRAL SPI

Diffuse emission is often challenging since it is undetectable by most instruments, which are generally dedicated to point-source studies. The {sup 26}Al emission is a good illustration: the only available {sup 26}Al map to date has been released, more than 15 yr ago, thanks to the COMPTEL instrument. However, at the present time, the SPI spectrometer aboard the International Gamma-Ray Astrophysics Laboratory mission offers a unique opportunity to enrich this first result. In this paper, 2 × 10{sup 8} s of data accumulated between 2003 and 2013 are used to perform a dedicated analysis, aiming to deeply investigate the spatial morphology of the {sup 26}Al emission. The data are first compared with several sky maps based on observations at various wavelengths to model the {sup 26}Al distribution throughout the Galaxy. For most of the distribution models, the inner Galaxy flux is compatible with a value of 3.3 × 10{sup −4} photons cm{sup −2} s{sup −1}, while the preferred template maps correspond to young stellar components such as core-collapse supernovae (SNe), Wolf–Rayet stars, and massive AGB stars. To get more details about this emission, an image reconstruction is performed using an algorithm based on the maximum-entropy method. In addition to the inner Galaxy emission, several excesses suggest that some sites of emission are linked to the spiral arm structure. Lastly, an estimation of the {sup 60}Fe line flux, assuming a spatial distribution similar to {sup 26}Al line emission, results in a {sup 60}Fe-to-{sup 26}Al ratio around 0.14, which agrees with the most recent studies and with the SN explosion model predictions.

79 ASTRONOMY AND ASTROPHYSICS↗

Positronium signature in organic liquid scintillators for neutrino experiments

Electron antineutrinos are commonly detected in liquid scintillator experiments via inverse {beta} decay by looking at the coincidence between the reaction products: neutrons and positrons. Prior to positron annihilation, an electron-positron pair may form an orthopositronium (o-Ps) state, with a mean lifetime of a few nanoseconds. Even if the o-Ps decay is speeded up by spin-flip or pick-off effects, it may introduce distortions in the photon emission time distribution, crucial for position reconstruction and pulse shape discrimination algorithms in antineutrino experiments. Reversing the problem, the o-Ps-induced time distortion represents a new signature for tagging antineutrinos in liquid scintillator. In this article, we report the results of measurements of the o-Ps formation probability and lifetime for the most used solvents for organic liquid scintillators in neutrino physics (pseudocumene, linear alkyl benzene, phenylxylylethane, and dodecane). We characterize also a mixture of pseudocumene +1.5 g/l of 2,5-diphenyloxazole, a fluor acting as wavelength shifter. In the second part of the article, we demonstrate that the o-Ps-induced distortion of the scintillation photon emission time distributions represent an optimal signature for tagging positrons on an event by event basis, potentially enhancing the antineutrino detection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

3D imaging of magnetic domains in Nd 2 Fe 14 B using scanning hard X-ray nanotomography

Nanoscale structural and electronic heterogeneities are prevalent in condensed matter physics. Investigating these heterogeneities in 3D has become an important task for understanding material properties. To provide a tool to unravel the connection between nanoscale heterogeneity and macroscopic emergent properties in magnetic materials, scanning transmission X-ray microscopy (STXM) is combined with X-ray magnetic circular dichroism. A vector tomography algorithm has been developed to reconstruct the full 3D magnetic vector field without any prior noise assumptions or knowledge about the sample. Two tomographic scans around the vertical axis are acquired on single-crystalline Nd 2 Fe 14 B pillars tilted at two different angles, with 2D STXM projections recorded using a focused 120 nm X-ray beam with left and right circular polarization. Image alignment and iterative registration have been implemented based on the 2D STXM projections for the two tilts. Dichroic projections obtained from difference images are used for the tomographic reconstruction to obtain the 3D magnetization distribution at the nanoscale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Three-dimensional nanostructure determination from a large diffraction data set recorded using scanning electron nanodiffraction

A diffraction-based technique is developed for the determination of three-dimensional nanostructures. The technique employs high-resolution and low-dose scanning electron nanodiffraction (SEND) to acquire three-dimensional diffraction patterns, with the help of a special sample holder for large-angle rotation. Grains are identified in three-dimensional space based on crystal orientation and on reconstructed dark-field images from the recorded diffraction patterns. Application to a nanocrystalline TiN thin film shows that the three-dimensional morphology of columnar TiN grains of tens of nanometres in diameter can be reconstructed using an algebraic iterative algorithm under specified prior conditions, together with their crystallographic orientations. The principles can be extended to multiphase nanocrystalline materials as well. Thus, the tomographic SEND technique provides an effective and adaptive way of determining three-dimensional nanostructures.

36 MATERIALS SCIENCE↗

Static metrology of the meter-scale deformable heliostat

This paper describes a heliostat metrology system which is developed based on deflectometry, utilizing a static perforated panel instead of conventional dynamic monitor displays to provide incident rays. The developed method is named static screen deflectometry (SSD). This robust and scalable method is especially valuable for outdoor tests of large reflectors used in concentrating solar-thermal power (CSP) systems. The developed method has been successfully demonstrated on a 2.4 𝑚 × 3.3 𝑚 float glass deformable reflector bent to focus sunlight at 113 𝑚 distance throughout a day. From images obtained from a camera at 50𝑚 distance, the reflector surface was measured to an accuracy of less than 1 𝑚𝑟𝑎𝑑 rms slope error in the full test scope.

14 SOLAR ENERGY↗

Resolution and noise trade-off analysis for volumetric CT

Until recently, most studies addressing the trade-off between spatial resolution and quantum noise were performed in the context of single-slice CT. In this study, we extend the theoretical framework of previous works to volumetric CT and further extend it by taking into account the actual shapes of the preferred reconstruction kernels. In the experimental study, we also attempt to explore a three-dimensional approach for spatial resolution measurement, as opposed to the conventional two-dimensional approaches that were widely adopted in previously published studies. By scanning a finite-sized sphere phantom, the MTF was measured from the edge profile along the spherical surface. Cases of different resolutions (and noise levels) were generated by adjusting the reconstruction kernel. To reduce bias, the total photon fluxes were matched: 120 kVp, 200 mA, and 1 s per gantry rotation. All data sets were reconstructed using a modified FDK algorithm under the same condition: Scan field-of-view (SFOV)=10 cm, and slice thickness=0.625 mm. The theoretical analysis indicated that the variance of noise is proportional to >4th power of the spatial resolution. Our experimental results supported this conclusion by showing the relationship is 4.6th (helical) or 5th (axial) power.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of BoneTtissue Mineralization by Conventional X-ray Microcomputed tomography: Comparison with Synchrotron Radiation Microcomputed Tomography and Ash Measurements

Assessment of bone tissue mineral density (TMD) may provide information critical to the understanding of mineralization processes and bone biomechanics. High-resolution three-dimensional assessment of TMD has recently been demonstrated using synchrotron radiation microcomputed tomography (SR{mu}CT); however, this imaging modality is relatively inaccessible due to the scarcity of SR facilities. Conventional desktop {mu}CT systems are widely available and have been used extensively to assess bone microarchitecture. However, the polychromatic source and cone-shaped beam geometry complicate assessment of TMD by conventional {mu}CT. The goal of this study was to evaluate {mu}CT-based measurement of degree and distribution of tissue mineralization in a quantitative, spatially resolved manner. Specifically, {mu}CT measures of bone mineral content (BMC) and TMD were compared to those obtained by SR{mu}CT and gravimetric methods. Cylinders of trabecular bone were machined from human femoral heads (n=5), vertebrae (n=5), and proximal tibiae (n=4). Cylinders were imaged in saline on a polychromatic {mu}CT system at an isotropic voxel size of 8 {mu}m. Volumes were reconstructed using beam hardening correction algorithms based on hydroxyapatite (HA)-resin wedge phantoms of 200 and 1200 mgHA/cm3. SR{mu}CT imaging was performed at an isotropic voxel size of 7.50 {mu}m at the National Synchrotron Light Source. Attenuation values were converted to HA concentration using a linear regression derived by imaging a calibration phantom. Architecture and mineralization parameters were calculated from the image data. Specimens were processed using gravimetric methods to determine ash mass and density. {mu}CT-based BMC values were not affected by altering the beam hardening correction. Volume-averaged TMD values calculated by the two corrections were significantly different (p=0.008) in high volume fraction specimens only, with the 1200 mgHA/cm3 correction resulting in a 4.7% higher TMD value. {mu}CT and SR{mu}CT provided significantly different measurements of both BMC and TMD (p<0.05). In high volume fraction specimens, {mu}CT with 1200 mgHA/cm3 correction resulted in BMC and TMD values 16.7% and 15.0% lower, respectively, than SR{mu}CT values. In low volume fraction specimens, {mu}CT with 1200 mgHA/cm3 correction resulted in BMC and TMD values 12.8% and 12.9% lower, respectively, than SR{mu}CT values. {mu}CT and SR{mu}CT values were well-correlated when volume fraction groups were considered individually (BMC R2=0.97-1.00; TMD R2=0.78-0.99). Ash mass and density were higher than the SR{mu}CT equivalents by 8.6% in high volume fraction specimens and 10.9% in low volume fraction specimens (p<0.05). BMC values calculated by tomography were highly correlated with ash mass (ash versus {mu}CT R2=0.96-1.00; ash versus SR{mu}CT R2=0.99-1.00). TMD values calculated by tomography were moderately correlated with ash density (ash versus {mu}CT R2=0.64-0.72; ash versus SR{mu}CT R2=0.64). Spatially resolved comparisons highlighted substantial geometric nonuniformity in the {mu}CT data, which were reduced (but not eliminated) using the 1200 mg HA/cm3 beam hardening correction, and did not exist in the SR{mu}CT data. This study represents the first quantitative comparison of {mu}CT mineralization evaluation against SR{mu}CT and gravimetry. Our results indicate that {mu}CT mineralization measures are underestimated but well-correlated with SR{mu}CT and gravimetric data, particularly when volume fraction groups are considered individually.

43 PARTICLE ACCELERATORS↗

Improved dosimetry for targeted radionuclide therapy using nonrigid registration on sequential SPECT images

Purpose: Voxel-level and patient-specific 3D dosimetry for targeted radionuclide therapy (TRT) typically involves serial nuclear medicine scans. Misalignment of the images can result in reduced dosimetric accuracy. Since the scans are typically performed over a period of several days, there will be patient movement between scans and possible nonrigid organ deformation. This work aims to implement and evaluate the use of nonrigid image registration on a series of quantitative SPECT (QSPECT) images for TRT dosimetry. Methods: A population of 4D extended cardiac torso phantoms, comprised of three In-111 Zevalin biokinetics models and three anatomical variations, was generated based on the patient data. The authors simulated QSPECT acquisitions at five time points. At each time point, individual organ and whole-body deformation between scans were modeled by translating/rotating organs and the body up to 5°/voxels, keeping ≤5% difference in organ volume. An analytical projector was used to generate realistic noisy projections for a medium energy general purpose collimator. Projections were reconstructed using OS-EM algorithm with geometric collimator detector response, attenuation, and scatter corrections. The QSPECT images were registered using organ-based nonrigid image registration method. The cumulative activity in each voxel was obtained by integrating the activity over time. Dose distribution images were obtained by convolving the cumulative activity images with a Y-90 dose kernel. Dose volume histograms (DVHs) for organs-of-interest were analyzed. Results: After nonrigid registration, the mean differences in organ doses compared to the case without misalignment were improved from (−15.50 ± 5.59)% to (−2.12 ± 1.05)% and (−7.28 ± 2.30)% to (−0.23 ± 0.71)% for the spleen and liver, respectively. For all organs, the cumulative DVHs showed improvement after nonrigid registration and the normalized absolute error of differential DVHs ranged from 6.79% to 22.70% for liver and 26.00% to 39.70% for spleen with different segmentation methods. Conclusions: These results demonstrated that nonrigid registration of sequential QSPECT images is feasible for TRT and improves the accuracy of 3D dosimetry.

60 APPLIED LIFE SCIENCES↗

SU-E-I-80: Quantification of Respiratory and Cardiac Motion Effect in SPECT Acquisitions Using Anthropomorphic Models: A Monte Carlo Simulation Study

Purpose: The purpose of the present study was to quantify, evaluate the impact of cardiac and respiratory motion on clinical nuclear imaging protocols. Common SPECT and scintigraphic scans are studied using Monte Carlo (MC) simulations, comparing the resulted images with and without motion. Methods: Realistic simulations were executed using the GATE toolkit and the XCAT anthropomorphic phantom as a reference model for human anatomy. Three different radiopharmaceuticals based on 99mTc were studied, namely 99mTc-MDP, 99mTc—N—DBODC and 99mTc—DTPA-aerosol for bone, myocardium and lung scanning respectively. The resolution of the phantom was set to 3.5 mm{sup 3}. The impact of the motion on spatial resolution was quantified using a sphere with 3.5 mm diameter and 10 separate time frames, in the ECAM modeled SPECT scanner. Finally, respiratory motion impact on resolution and imaging of lung lesions was investigated. The MLEM algorithm was used for data reconstruction, while the literature derived biodistributions of the pharmaceuticals were used as activity maps in the simulations. Results: FWHM was extracted for a static and a moving sphere which was ∼23 cm away from the entrance of the SPECT head. The difference in the FWHM was 20% between the two simulations. Profiles in thorax were compared in the case of bone scintigraphy, showing displacement and blurring of the bones when respiratory motion was inserted in the simulation. Large discrepancies were noticed in the case of myocardium imaging when cardiac motion was incorporated during the SPECT acquisition. Finally the borders of the lungs are blurred when respiratory motion is included resulting to a dislocation of ∼2.5 cm. Conclusion: As we move to individualized imaging and therapy procedures, quantitative and qualitative imaging is of high importance in nuclear diagnosis. MC simulations combined with anthropomorphic digital phantoms can provide an accurate tool for applications like motion correction techniques’ optimization. This research has been co-funded by the European Union (European Social Fund) and Greek national resources under the framework of the ‘Archimedes III: Funding of Research Groups in TEI of Athens’ project of the ‘Education & Lifelong Learning’ Operational Programme.

60 APPLIED LIFE SCIENCES↗