Search NASA⌕ Search

SEARCH · Search NASA

Results for “Repeatability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Molecular Architecture of the Transport Channel of the Nuclear Pore Complex

The nuclear pore complex encloses a central channel for nucleocytoplasmic transport, which is thought to consist of three nucleoporins, Nup54, Nup58, and Nup62. However, the structure and composition of the channel are elusive. We determined the crystal structures of the interacting domains between these nucleoporins and pieced together the molecular architecture of the mammalian transport channel. Located in the channel midplane is a flexible Nup54Nup58 ring that can undergo large rearrangements yielding diameter changes from {approx}20 to {approx}40 nm. Nup62Nup54 triple helices project alternately up and down from either side of the midplane ring and form nucleoplasmic and cytoplasmic entries. The channel consists of as many as 224 copies of the three nucleoporins, amounting to a molar mass of 12.3 MDa and contributing 256 phenylalanine-glycine repeat regions. We propose that the occupancy of these repeat regions with transport receptors modulates ring diameter and transport activity.

36 MATERIALS SCIENCE↗

Recyclability of reversible polymer networks over a Dozen reprocessing cycles

Reversible polymer networks capable of reversible reactions along their backbone provide a promising strategy for addressing waste management challenges associated with conventional thermoset products. However, reversible polymer networks cannot be recycled infinitely. Unavoidable side reactions eventually cause significant degradation of mechanical properties or loss of recyclability. This study aims to answer a simple yet critical question on reversible polymer network systems: how many reprocessing cycles can be achieved before profound mechanical degradation or a loss of recyclability? The recyclability of Diels–Alder (DA) network samples was evaluated by repeating consistent reprocessing cycles until they were no longer reprocessable. To enhance their recyclability, the chemical structure of the maleimide precursor was tailored to mitigating side reactions by maleimide homopolymerization. Remarkably, by employing a maleimide precursor with alkyl substitutions on its phenyl group, the DA network system attained 12 reprocessing cycles using injection molding at 160 °C without significant degradation of mechanical properties. However, the 13th reprocessing cycle did not succeed. Rheological analysis revealed the accumulation of non-reversible bonds within the network structure during repeated reprocessing, despite fairly consistent mechanical properties under operating conditions. This study demonstrates that the rational design of the maleimide precursor is an effective means to enhance the reprocessability of DA networks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The role of spray-enhanced swirl flow for combustion stabilization in a stratified-charge DISI engine

Implementing spray-guided stratified-charge direct-injection spark-ignited (DISI) engines is inhibited by the occurrence of misfire and partial burns. Engine-performance tests demonstrate that increasing engine speed induces combustion instability, but this deterioration can be prevented by generating swirling flow during the intake stroke. In-cylinder pressure-based heat-release analysis reveals that the appearance of poor-burn cycles is not solely dependent on the variability of early flame-kernel growth. Moreover, cycles can experience burning-rate regression during later combustion stages and may or may not recover before the end of the cycle. Thermodynamic analysis and optical diagnostics are used here to clarify why swirl improves the combustion repeatability from cycle to cycle. The fluid dynamics of swirl/spray interaction was previously demonstrated using high-speed PIV measurements of in-cylinder motored flow. It was found that the sprays of the multi-hole injector redistribute the intake-generated swirl flow momentum, thereby creating a better-centered higher angular-momentum vortex with reduced variability. The engine operation with high swirl was found to have significant improvement in cycle-to-cycle variations of both flow pattern and flow momentum. This paper is an extension of the previous work. Here, PIV measurements and flame imaging are applied to fired operation for studying how the swirl flow affects variability of ignition and subsequent combustion phases. PIV results for fired operation are consistent with the measurements made of motored flow. They demonstrate that the spark-plasma motion is highly correlated with the direction of the gas flow in the vicinity of the spark-plug gap. Without swirl, the plasma is randomly stretched towards either side of the spark plug, causing variability in the ignition of the two spray plumes that are straddling the spark plug. Conversely, swirl flow always convects the spark plasma towards one spray plume, causing a more repeatable ignition. The swirl decreases local RMS velocity, consistent with an observed reduction of early-burn variability. Broadband flame imaging demonstrates that with swirl, the flame consistently propagates in multiple directions to consume fuel–air mixtures within the piston bowl. In contrast, operation without swirl displays higher variability of flame-spread patterns, occasionally causing the appearance of partial-burn cycles.

33 ADVANCED PROPULSION SYSTEMS↗

Multi-objective optimization techniques to design the Pareto front of organic dielectric polymers

Here, we present two Monte Carlo algorithms to find the Pareto front of the chemical space of a class of dielectric polymers that is most interesting with respect to optimizing both the bandgap and dielectric constant. Starting with a dataset generated from density functional theory calculations, we used machine learning to construct surrogate models for the bandgaps and dielectric constants of all physically meaningful 4-block polymers (that is, polymer systems with a 4-block repeat unit). We parameterized these machine learning models in such a way that the surrogates built for the 4-block polymers were readily extendable to polymers beyond a 4-block repeat unit. By using translational invariance, chemical intuition, and domain knowledge, we were able to enumerate all possible 4, 6, and 8 block polymers and benchmark our Monte Carlo sampling of the chemical space against the exact enumeration of the surrogate predictions. We obtained exact agreement for the fronts of 4-block polymers and at least a 90% agreement for those of 6 and 8-block polymers. We present fronts for 10-block polymer that are not possible to obtain by direct enumeration. We note that our Monte Carlo methods also return polymers close to the predicted front and a measure of the closeness. Both quantities are useful information for the design and discovery of new polymers.

36 MATERIALS SCIENCE↗

Application of electron backscatter diffraction techniques to quantify effects of aging on sub-grain and spatial heterogeneity in NMC cathodes

Identification and evaluation of structural heterogeneity in spent cathode materials is crucial to developing appropriate remediation strategies for novel recycling processes. Native heterogeneities may be exacerbated during the cell's operational lifetime, as sub-particle-scale variations induce anisotropic expansion and contraction upon cycling. Structural transformations resulting from repeated cycling and calendar aging predominantly occur at the secondary particle surface and at the grain boundaries (GBs) between primary particles. However, the diffusion and stress build up around and across GBs are poorly understood. In this study, electron backscatter diffraction (EBSD) is employed to track sub-grain lattice structure across a statistically relevant number of Li(Ni0.33Mn0.33Co0.33)O2 (NMC-111) particles. Specifically, differences in lattice misorientation – measured as the deviation from the grain's average orientation – are tracked as a function of position within the electrode (near current collector, middle, and near separator) and as a function of electrochemical cycling. Further, a novel method of structural analysis is developed, offering insight into sub-grain diffusion behavior by comparing lattice misorientation near the grain boundary versus in the grain bulk. The present results suggest that electrode-scale spatial heterogeneity in lattice structure is induced by initial manufacturing conditions, and that radial gradients in lattice misorientation evolve at the primary particle scale with repeated electrochemical cycling.

25 ENERGY STORAGE↗

Experimental density and PC-SAFT modeling of Krytox (R) (perfluoropolyether) at pressures to 275 MPa and temperatures to 533 K

Density data from 298 to 533 K and to 275 MPa are reported for Krytox® GPL 102, a poly(perfluoropropyl ether) (PFPE) with a CF3-branched fluoropropylether repeat group. The Tait equation fit to each density isotherm have mean absolute percent deviations (MAPD) between 0.11 and 0.30% with standard deviations (SD) not exceeding 0.20%. The perturbed-chain statistical associating fluid theory (PC-SAFT) fit to the density data has an MAPD of 0.67% and an SD of 0.67%. Likewise the PC-SAFT fit to previously reported density data of Demnum®, a PFPE with an n-fluoropropylether repeat group, has an MAPD of 0.22% and a SD of 0.21% for Demnum® S-20 and an MAPD of 0.27% with a SD of 0.14% for Demnum® S-65. The trends exhibited by the PC-SAFT pure component parameters obtained from the fits of these three PFPEs are similar to those reported for linear and branched hydrocarbons with the same number of carbons.

42 ENGINEERING↗

Planning, design and logistics of a decision analysis study: The FBI/Ames study involving forensic firearms examiners

This paper describes design and logistical aspects of a decision analysis study to assess the performance of qualified firearms examiners working in accredited laboratories in the United States in terms of accuracy (error rate), repeatability, and reproducibility of decisions involving comparisons of fired bullets and cartridge cases. The purpose of the study was to validate current practice of the forensic discipline of firearms/toolmarks (F/T) examination. It elicited error rate data by counting the number of false positive and false negative conclusions. Preceded by the experimental design, decisions, and logistics described herein, testing was ultimately administered 173 qualified, practicing F/T examiners in public and private crime laboratories. The first round of testing evaluated accuracy, while two subsequent rounds evaluated repeatability and reproducibility of examiner conclusions. This project expands on previous studies by involving many F/T examiners in challenging comparisons and by executing the study in the recommended double-blind format.

99 GENERAL AND MISCELLANEOUS↗

Oxidation and Associated Pore Structure Modification During Experimental Alteration of Granite

Weathering plays a crucial role in a number of environmental processes, and the microstructure and evolution of multi-scale pore space is a critically important factor in the weathering of geological formations. In igneous rocks the infiltration of meteoric water into initially relatively dry material can cause the rock to begin to disaggregate, increasing porosity and surface area, and allowing further disaggregation and weathering to occur. These processes, in turn, allow biota to colonize the rock, further enhancing the weathering rate. In some igneous rocks this may be driven by oxidation of primary minerals. One such mineral, biotite, has been repeatedly mentioned as a cause of cracking during oxidation. However, the scale-dependence of the processes by which this occurs are poorly understood. We cannot, therefore, accurately extrapolate laboratory reaction rates to the field in predictive numerical models. In order to better understand the effects of oxidation and test the hypothesis that fracture and disaggregation are initiated by swelling of oxidizing biotites, we reacted granite cores in a selenic acid-rich aqueous solution at 200°C for up to 438 days. Elevated temperatures and selenic acid were used to provide relatively fast reaction rates and highly oxidizing conditions in sealed reaction vessels. These experiments were analyzed using a combination of imaging, X-ray diffraction, Mössbauer spectroscopy, and small- and ultra-small angle neutron scattering to interrogate porosity and microfracture formation. The experimental results show little observable biotite swelling, but significant transport and growth of iron oxides and/or clays along grain boundaries throughout the sample. Significant increases in porosity were also observed at the sample rim, likely associated with feldspar alteration. Fractures and transport were observed throughout the core, suggesting that stresses due to crystallization pressures caused by the growing iron phases may be the initiating factors in granite weathering, possibly followed by biotite swelling after sufficient permeability is achieved.

Anovitz, Lawrence M.↗

Comparison of steady and transient flow boiling critical heat flux for FeCrAl accident tolerant fuel cladding alloy, Zircaloy, and Inconel

Steady and transient (with a heating rate of 685?/s) internal-flow CHF (Critical Heat Flux) experiments were conducted under atmospheric pressure at a fixed inlet temperature (40? or 60?) and mass flow (300kg/m 2 s) on Fe-13Cr-6Al alloy, Inconel 600 and Zircaloy-4 tube samples. Multiple experiments were repeated on the same specimen to investigate the effect of surface characteristic changes (i.e., roughness, wettability, and oxide scale morphology) on the occurrence of CHF. Despite notable changes of wettability, roughness, and oxide layer characteristics on samples that had already been subjected to CHF, measured flow CHF remained unchanged throughout repeated experiments for tested materials. This demonstrates that the surface effects on flow CHF are limited in the test conditions. In the steady-state flow boiling condition, Fe-13Cr-6Al alloy demonstrated a 22% and 14% increase in CHF compared to Zircaloy-4 and Inconel 600, respectively. Compared to the 2006 Groeneveld CHF lookup table, Fe-13Cr-6Al alloy gives a 13% increase in the tested flow boiling condition. Material properties are considered primarily responsible for the observed CHF differences among the tested materials. The surface thermal economy parameter $\frac{(pc_p)^{3/2}}{\sqrt{k}}$ is proposed as an explanation for the observed CHF differences; this parameter is related to material’s ability to avoid an irreversible dry spot formation. The apparent disagreement of Zircaloy-4 CHF with both the look up table predictions and Inconel 600 shows the limitation of departure of nuclate boiling (DNB) evaluations that do not consider cladding materials. The transient Fe-13Cr-6Al CHF is 39% and 23% higher than the lookup table prediction and the steady-state condition experimental result, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Use of Respiratory-Correlated Four-Dimensional Computed Tomography to Determine Acceptable Treatment Margins for Locally Advanced Pancreatic Adenocarcinoma

Purpose: Respiratory-induced excursions of locally advanced pancreatic adenocarcinoma could affect dose delivery. This study quantified tumor motion and evaluated standard treatment margins. Methods and Materials: Respiratory-correlated four-dimensional computed tomography images were obtained on 30 patients with locally advanced pancreatic adenocarcinoma; 15 of whom underwent repeat scanning before cone-down treatment. Treatment planning software was used to contour the gross tumor volume (GTV), bilateral kidneys, and biliary stent. Excursions were calculated according to the centroid of the contoured volumes. Results: The mean +- standard deviation GTV excursion in the superoinferior (SI) direction was 0.55 +- 0.23 cm; an expansion of 1.0 cm adequately accounted for the GTV motion in 97% of locally advanced pancreatic adenocarcinoma patients. Motion GTVs were generated and resulted in a 25% average volume increase compared with the static GTV. Of the 30 patients, 17 had biliary stents. The mean SI stent excursion was 0.84 +- 0.32 cm, significantly greater than the GTV motion. The xiphoid process moved an average of 0.35 +- 0.12 cm, significantly less than the GTV. The mean SI motion of the left and right kidneys was 0.65 +- 0.27 cm and 0.77 +- 0.30 cm, respectively. At repeat scanning, no significant changes were seen in the mean GTV size (p = .8) or excursion (p = .3). Conclusion: These data suggest that an asymmetric expansion of 1.0, 0.7, and 0.6 cm along the respective SI, anteroposterior, and medial-lateral directions is recommended if a respiratory-correlated four-dimensional computed tomography scan is not available to evaluate the tumor motion during treatment planning. Surrogates of tumor motion, such as biliary stents or external markers, should be used with caution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results of a Multi-Institution Deformable Registration Accuracy Study (MIDRAS)

Purpose: To assess the accuracy, reproducibility, and computational performance of deformable image registration algorithms under development at multiple institutions on common datasets. Methods and Materials: Datasets from a lung patient (four-dimensional computed tomography [4D-CT]), a liver patient (4D-CT and magnetic resonance imaging [MRI] at exhale), and a prostate patient (repeat MRI) were obtained. Radiation oncologists localized anatomic structures for accuracy assessment. Algorithm accuracy was determined by comparing the computer-predicted displacement at each bifurcation point with the displacement computed from the oncologists' annotations. Thirty-seven academic institutions and medical device manufacturers with published evidence of active deformable image registration capabilities were invited to participate. Results: Twenty-seven groups agreed to participate; 6 did not return results. Sixteen completed the liver 4D-CT, 12 the lung 4D-CT, 3 the prostate MRI, and 3 the liver MRI-CT. The range of average absolute error for the lung 4D-CT was 0.6-1.2 mm (left-right [LR]), 0.5-1.8 mm (anterior-posterior [AP]), and 0.7-2.0 mm (superior-inferior [SI]); the liver 4D-CT was 0.8-1.5 mm (LR), 1.0-5.2 mm (AP), and 1.0-5.9 mm (SI); the liver MRI-CT was 1.1-2.6 mm (LR), 2.0-5.0 mm (AP), and 2.2-2.6 mm (SI); and the repeat prostate MRI prostate datasets was 0.5-6.2 mm (LR), 3.1-3.7 mm (AP), and 0.4-2.0 mm (SI). Conclusions: An infrastructure was developed to assess multi-institution deformable registration accuracy. The results indicate large discrepancies in reported shifts, although the majority of deformable registration algorithms performed at an accuracy equivalent to the voxel size, promising to improve treatment planning, delivery, and assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Standardized Uptake Value-Based Positron Emission Tomography and Computed Tomography Target Volumes in Esophageal Cancer Patients Undergoing Radiotherapy

Purpose: To study various standardized uptake value (SUV)-based approaches to ascertain the best strategy for delineating metabolic tumor volumes (MTV). Methods and Materials: Twenty-two consecutive previously treated esophageal cancer patients with positron emission tomography (PET) imaging and computed tomography (CT)-based radiotherapy plans were studied. At the level of the tumor epicenter, MTVs were delineated at 11 different thresholds: SUV {>=}2, {>=}2.5, {>=}3, {>=}3.5 (SUV{sub n}); {>=}40%, {>=}45%, and {>=}50% of the maximum (SUV{sub n%}); and mean liver SUV + 1, 2, 3, and 4 standard deviations (SUV{sub Ln{sigma}}). The volume ratio and conformality index were determined between MTVs, and the corresponding CT/endoscopic ultrasound-based gross tumor volume (GTV) at the epicenter. Means were analyzed by one-way analysis of variance for repeated measures and further compared using a paired t test for repeated measures. Results: The mean conformality indices ranged from 0.33 to 0.48, being significantly (p < 0.05) closest to 1 at SUV{sub 2.5} (0.47 {+-} 0.03) and SUV{sub L4{sigma}} (0.48 {+-} 0.03). The mean volume ratios ranged from 0.39 to 2.82, being significantly closest to 1 at SUV{sub 2.5} (1.18 {+-} 0.36) and SUV{sub L4{sigma}} (1.09 {+-} 0.15). The mean value of the SUVs calculated using the SUV{sub L4{sigma}} approach was 2.4. Conclusions: Regardless of the SUV thresholding method used (i.e., absolute or relative to liver mean), a threshold of approximately 2.5 yields the highest conformality index and best approximates the CT-based GTV at the epicenter. These findings may ultimately aid radiation oncologists in the delineation of the entire GTV in esophageal cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive-Predictive Organ Localization Using Cone-Beam Computed Tomography for Improved Accuracy in External Beam Radiotherapy for Bladder Cancer

Purpose: To examine patterns of bladder wall motion during high-dose hypofractionated bladder radiotherapy and to validate a novel adaptive planning method, A-POLO, to prevent subsequent geographic miss. Methods and Materials: Patterns of individual bladder filling were obtained with repeat computed tomography planning scans at 0, 15, and 30 minutes after voiding. A series of patient-specific plans corresponding to these time-displacement points was created. Pretreatment cone-beam computed tomography was performed before each fraction and assessed retrospectively for adaptive intervention. In fractions that would have required intervention, the most appropriate plan was chosen from the patient's 'library,' and the resulting target coverage was reassessed with repeat cone-beam computed tomography. Results: A large variation in patterns of bladder filling and interfraction displacement was seen. During radiotherapy, predominant translations occurred cranially (maximum 2.5 cm) and anteriorly (maximum 1.75 cm). No apparent explanation was found for this variation using pretreatment patient factors. A need for adaptive planning was demonstrated by 51% of fractions, and 73% of fractions would have been delivered correctly using A-POLO. The adaptive strategy improved target coverage and was able to account for intrafraction motion also. Conclusions: Bladder volume variation will result in geographic miss in a high proportion of delivered bladder radiotherapy treatments. The A-POLO strategy can be used to correct for this and can be implemented from the first fraction of radiotherapy; thus, it is particularly suited to hypofractionated bladder radiotherapy regimens.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Evaluation of Soft Tissue Organ Boundary Visualization on Cone-Beam Computed Tomographic Imaging

Purpose: Cone-beam computed tomographic images (CBCTs) are increasingly used for setup correction, soft tissue targeting, and image-guided adaptive radiotherapy. However, CBCT image quality is limited by low contrast and imaging artifacts. This analysis investigates the detectability of soft tissue boundaries in CBCT by performing a multiple-observer segmentation study. Methods and Materials: In four prostate cancer patients prostate, bladder and rectum were repeatedly delineated by five observers on CBCTs and fan-beam CTs (FBCTs). A volumetric analysis of contouring variations was performed by calculating coefficients of variation (COV: standard deviation/average volume). The topographical distribution of contouring variations was analyzed using an average surface mesh-based method. Results: Observer- and patient-averaged COVs for FBCT/CBCT were 0.09/0.19 for prostate, 0.05/0.08 for bladder, and 0.09/0.08 for rectum. Contouring variations on FBCT were significantly smaller than on CBCT for prostate (p < 0.03) and bladder (p < 0.04), but not for rectum (p < 0.37; intermodality differences). Intraobserver variations from repeated contouring of the same image set were not significant for either FBCT or CBCT (p < 0.05). Average standard deviations of individual observers' contour differences from average surface meshes on FBCT vs. CBCT were 1.5 vs. 2.1 mm for prostate, 0.7 vs. 1.4 mm for bladder, and 1.3 vs. 1.5 mm for rectum. The topographical distribution of contouring variations was similar for FBCT and CBCT. Conclusion: Contouring variations were larger on CBCT than FBCT, except for rectum. Given the well-documented uncertainty in soft tissue contouring in the pelvis, improvement of CBCT image quality and establishment of well-defined soft tissue identification rules are desirable for image-guided radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate-Specific Antigen Velocity Before and After Elimination of Factors That Can Confound the Prostate-Specific Antigen Level

Purpose: Prostate-specific antigen (PSA) velocity, like PSA level, can be confounded. In this study, we estimated the impact that confounding factors could have on correctly identifying a patient with a PSA velocity >2 ng/ml/y. Methods and Materials: Between 2006 and 2010, a total of 50 men with newly diagnosed PC comprised the study cohort. We calculated and compared the false-positive and false-negative PSA velocity >2 ng/ml/y rates for all men and those with low-risk disease using two approaches to calculate PSA velocity. First, we used PSA values obtained within 18 months of diagnosis; second, we used values within 18 months of diagnosis, substituting the prebiopsy PSA for a repeat, nonconfounded PSA that was obtained using the same assay and without confounders. Results: Using PSA levels pre-biopsy, 46% of all men had a PSA velocity >2 ng/ml/y; whereas this value declined to 32% when substituting the last prebiopsy PSA for a repeat, nonconfounded PSA using the same assay and without confounders. The false-positive rate for PSA velocity >2 ng/ml/y was 43% as compared with a false-negative rate of PSA velocity >2 ng/ml/y of 11% (p = 0.0008) in the overall cohort. These respective values in the low-risk subgroup were 60% and 16.7% (p = 0.09). Conclusion: This study provides evidence to explain the discordance in cancer-specific outcomes among groups investigating the prognostic significance of PSA velocity >2 ng/ml/y, and highlights the importance of patient education on potential confounders of the PSA test before obtaining PSA levels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated Partial Breast Irradiation With Low-Dose-Rate Interstitial Implant Brachytherapy After Wide Local Excision: 12-Year Outcomes From a Prospective Trial

Purpose: To evaluate the long-term toxicity, cosmesis, and local control of accelerated partial breast irradiation with implant brachytherapy after wide local excision for Stage T1N0 breast cancer (BCa). Materials and Methods: Between 1997 and 2001, 50 patients with Stage T1N0M0 BCa were treated in a Phase I-II protocol using low-dose-rate accelerated partial breast irradiation with implant brachytherapy after wide local excision and lymph node surgery. The total dose was escalated in three groups: 50 Gy (n = 20), 55 Gy (n = 17), and 60 Gy (n = 13). Patient- and physician-assessed breast cosmesis, patient satisfaction, toxicity, mammographic abnormalities, repeat biopsies, and disease status were prospectively evaluated at each visit. Kendall's tau ({tau}{sub {beta}}) and logistic regression analyses were used to correlate outcomes with dose, implant volume, patient age, and systemic therapy. Results: The median follow-up period was 11.2 years (range, 4-14). The patient satisfaction rate was 67%, 67% reported good-excellent cosmesis, and 54% had moderate-severe fibrosis. Higher dose was correlated with worse cosmetic outcome ({tau}{sub {beta}} 0.6, p < .0001), lower patient satisfaction ({tau}{sub {beta}} 0.5, p < .001), and worse fibrosis ({tau}{sub {beta}} 0.4, p = .0024). Of the 50 patients, 35% had fat necrosis and 34% developed telangiectasias {>=}1 cm{sup 2}. Grade 3-4 late skin and subcutaneous toxicities were seen in 4 patients (9%) and 6 patients (13%), respectively, and both correlated with higher dose ({tau}{sub {beta}} 0.3-0.5, p {<=} .01). One patient had Grade 4 skin ulceration and fat necrosis requiring surgery. Mammographic abnormalities were seen in 32% of the patients, and 30% underwent repeat biopsy, of which 73% were benign. Six patients had ipsilateral breast recurrence: five elsewhere in the breast, and one at the implant site. One patient died of metastatic BCa after recurrence. The 12-year actuarial local control, recurrence-free survival, and overall survival rate was 85% (95% confidence interval, 70-97%), 72% (95% confidence interval, 54-86%), and 87% (95% confidence interval, 73-99%), respectively. Conclusion: Low-dose-rate accelerated partial breast irradiation with implant brachytherapy provides acceptable local control in select early-stage BCa patients. However, treatment-related toxicity and cosmetic complications were significant with longer follow-up and at higher doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Dosimetric Consequences of Seroma Contour Variability in Accelerated Partial Breast Irradiation Using a Constructed Representative Seroma Contour

Purpose: Contouring variability of the seroma can have important implications in the planning and delivery of accelerated partial breast irradiation (APBI). This study aimed to quantify the dosimetric impact of these interobserver and intraobserver contouring variations by construction of a representative seroma contour (RSC). Methods and Materials: Twenty-one patients with a seroma suitable for APBI underwent four computed tomography (CT) scans: one planning CT and three additional CTs on the first, third, and fifth days of treatment. Three radiation oncologists contoured the seroma on each CT scan. For 3 patients, oncologists repeated contouring twice to assess intraobserver variations. Seroma contour variability was quantified by construction of an RSC. In addition, the percent volume overlap (PVO) was calculated. Root-mean-square (RMS) differences in seroma volume, size, and center of mass position compared to those of the RSC were calculated. Treatment fields from the original plan were applied to the repeated CTs by using the same isocenter shifts as the original plan. The dosimetric impact of the contour variations was assessed using V{sub 95} (volume receiving at least 95% of the prescribed dose) and equivalent uniform dose (EUD). Results: Interobserver RMS volume differences were, on average, 5.6 times larger than intraobserver differences. The median interobserver RMS seroma volume difference was 1.48 cm{sup 3}. The median PVO was 51.6%. V{sub 95} and EUD of the seroma contours were similar for all patients. The median RMS differences of the seroma V{sub 95} and EUD were 0.01% (range, 0%-3.99%) and 0.05 Gy (range, 0-0.98 Gy). Conclusions: Construction of the RSC showed that interobserver variations were most responsible for contour variations of the seroma. Current planning margins provided adequate dose coverage of the seroma despite these contour variations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗