Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL PROCESSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Digital Pulse-Shape Discrimination Applied to an Ultra-Low-Background Gas-Proportional Counting System: First Results

Abstract A new ultra-low-background proportional counter (ULBPC) design was recently developed at Pacific Northwest National Laboratory (PNNL). This design, along with an ultra-low-background counting system (ULBCS) which provides passive and active shielding with radon exclusion, has been developed to complement a new shallow underground laboratory (~30 meters water-equivalent) constructed at PNNL. After these steps to mitigate dominant backgrounds (cosmic rays, external gamma-rays, radioactivity in materials), remaining background events do not exclusively arise from ionization of the proportional counter gas. Digital pulse-shape discrimination (PSD) is thus employed to further improve measurement sensitivity. In this work, a template shape is generated for each individual sample measurement of interest, a "self-calibrating" template. Differences in event topology can also cause differences in pulse shape. In this work, the temporal region analyzed for each event is refined to maximize background discrimination while avoiding unwanted sensitivity to event topology. This digital PSD method is applied to sample and background data, and initial measurement results from a biofuel methane sample are presented in the context of low-background measurements currently being developed.

signal processing, pulse-shape discrimination, pro↗

Detecting isolated resonance curves using fixed frequency voltage control tests

Isolated resonance curves, or isolas, are resonance branches of the harmonically forced system that exist separately from the main nonlinear forced response curve, leading to excessive vibrations. Traditional stepped or swept sine simulations and tests rely on continuation along the frequency parameter, typically resulting in a jump phenomenon along the primary resonance branch, prior to the disconnected isola. The main objective of this research is to propose an approach to identify isolated resonance curves by performing continuation along the input amplitude that initializes the response from a low-amplitude solution in the linear regime. Furthermore, this is achieved with the open-loop fixed frequency voltage control method that continues along the shaker voltage parameter and measures the so-called S-curves, which are theoretically a continuous solution branch that connect to the isola. The methodology is demonstrated on a fixture-wing-pylon assembly with a vibro-impact nonlinearity localized in a pylon subcomponent attachment. Multi-harmonic balance simulations are deployed to compute both the nonlinear forced response curves and S-curves to demonstrate the isola detection strategy on a reduced-order finite element model of the nonlinear system. Swept sine and fixed frequency voltage control tests are then conducted on the physical structure to demonstrate the isola detection experimentally, revealing the existence of the large amplitude vibrations that are undetected in the forces levels and frequencies measured with traditional frequency sweeping.

Characterization and Analytical Technique↗

Engineering supported membranes for cell biology

Cell membranes exhibit multiple layers of complexity, ranging from their specific molecular content to their emergent mechanical properties and dynamic spatial organization. Both compositional and geometrical organizations of membrane components are known to play important roles in life processes, including signal transduction. Supported membranes, comprised of a bilayer assembly of phospholipids on the solid substrate, have been productively served as model systems to study wide range problems in cell biology. Because lateral mobility of membrane components is readily preserved, supported lipid membranes with signaling molecules can be utilized to effectively trigger various intercellular reactions. The spatial organization and mechanical deformation of supported membranes can also be manipulated by patterning underlying substrates with modern micro- and nano-fabrication techniques. This article focuses on various applications and methods to spatially patterned biomembranes by means of curvature modulations and spatial reorganizations, and utilizing them to interface with live cells. The integration of biological components into synthetic devices provides a unique approach to investigate molecular mechanisms in cell biology.

59 BASIC BIOLOGICAL SCIENCES↗

SPARTA: A flux adjustment methodology to interpret complex experiments

For the accurate determination of reactivity from a detector count rate, correction of spatial effects is of prime importance. This spatial correction is often provided using simulation methodologies, but this may introduce a bias if the result of the experiment is also used as input data for the simulation. Here, this work presents a flux adjustment methodology able to infer experimental reactivity and correction of spatial effects without the need for a simulation. It can process the signal from a complex experiment such as a heat balance measurement in the TREAT reactor, where control rods are continuously adjusted to maintain a constant power. In the present work, this methodology successfully computed the reactivity and the local spatial variation of the flux of a generated signal. It also proved to be robust against noise and errors on kinetic parameters and provides a credible interpretation of a heat balance experiment in TREAT. Efficiency of flux adjustment methods for complex experiment enable a better experiment interpretation less reliant on nuclear data evaluation.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Accurate activity determination of a californium neutron source

Accurately counting analog events requires constructing an electronics chain that produces one count for each input pulse. Here, in this work, we review the use of Nuclear Instrumentation Module electronic units for counting neutron capture events in a 3He tube. We identify two unique types of false trigger events in a leading-edge discriminator and show how a dual timer module can be used to produce a veto window to exclude these events. We use the constructed electronics chain to build an apparatus to measure neutron pulses from a 252 Cf neutron source. We compare the measurements with a Monte Carlo N-Particle (MCNP) model to determine the activity of the neutron source. Furthermore, by making additional measurements with borated polyethylene attenuators between the source and detector, we are able to determine the boron concentration of the polyethylene. This technique provides accurate determination of the source activity to a precision of 2.8% at the k=1 level. The method used is simple, inexpensive, and requires no additional calibrated instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First upper limits on the radar cross section of cosmic-ray induced extensive air showers

TARA (Telescope Array Radar) is a cosmic ray radar detection experiment colocated with Telescope Array, the conventional surface scintillation detector (SD) and fluorescence telescope detector (FD) near Delta, Utah, U.S.A. Furthermore, the TARA detector combines a 40 kW, 54.1 MHz VHF transmitter and high-gain transmitting antenna which broadcasts the radar carrier over the SD array and within the FD field of view, towards a 250 MS/s DAQ receiver. TARA has been collecting data since 2013 with the primary goal of observing the radar signatures of extensive air showers (EAS). Simulations indicate that echoes are expected to be short in duration (~10 µs) and exhibit rapidly changing frequency, with rates on the order 1 MHz/µs. The EAS radar cross-section (RCS) is currently unknown although it is the subject of over 70 years of speculation. One novel signal search technique is described in which the expected radar echo of a particular air shower is used as a matched filter template and compared to waveforms obtained by triggering the radar DAQ using the Telescope Array fluorescence detector. No evidence for the scattering of radio frequency radiation by EAS is obtained to date. Finally, we report the first quantitative RCS upper limits using EAS that triggered the Telescope Array Fluorescence Detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Glycogen Synthase Kinase 3 (GSK-3) influences epithelial barrier function by regulating Occludin, Claudin-1 and E-cadherin expression

The Apical Junctional Complex (AJC) encompassing the tight junction (TJ) and adherens junction (AJ) plays a pivotal role in regulating epithelial barrier function and epithelial cell proliferative processes through signaling events that remain poorly characterized. A potential regulator of AJC protein expression is Glycogen Synthase Kinase-3 (GSK-3). GSK-3 is a constitutively active kinase that is repressed during epithelial-mesenchymal transition (EMT). In the present study, we report that GSK-3 activity regulates the structure and function of the AJC in polarized model intestinal (SK-CO15) and kidney (Madin-Darby Canine Kidney (MDCK)) epithelial cells. Reduction of GSK-3 activity, either by small molecule inhibitors or siRNA targeting GSK-3 alpha and beta mRNA, resulted in increased permeability to both ions and bulk solutes. Immunofluorescence labeling and immunoblot analyses revealed that the barrier defects correlated with decreased protein expression of AJC transmembrane proteins Occludin, Claudin-1 and E-cadherin without influencing other TJ proteins, Zonula Occludens-1 (ZO-1) and Junctional Adhesion Molecule A (JAM-A). The decrease in Occludin and E-cadherin protein expression correlated with downregulation of the corresponding mRNA levels for these respective proteins following GSK-3 inhibition. These observations implicate an important role of GSK-3 in the regulation of the structure and function of the AJC that is mediated by differential modulation of mRNA transcription of key AJC proteins, Occludin, Claudin-1 and E-cadherin.

60 APPLIED LIFE SCIENCES↗

Mining secreted proteins that function in pepper fruit development and ripening using a yeast secretion trap (YST)

Highlights: • Yeast secretion trap (YST) is a valuable tool for mining secretome. • A total of 80 secreted proteins are newly identified via YST in pepper fruits. • The secreted proteins are differentially regulated during pepper development and ripening. • Transient GFP-fusion assay and in planta secretion trap can effectively validate the secretion of proteins. - Abstract: Plant cells secrete diverse sets of constitutively- and conditionally-expressed proteins under various environmental and developmental states. Secreted protein populations, or secretomes have multiple functions, including defense responses, signaling, metabolic processes, and developmental regulation. To identify genes encoding secreted proteins that function in fruit development and ripening, a yeast secretion trap (YST) screen was employed using pepper (Capsicum annuum) fruit cDNAs. The YST screen revealed 80 pepper fruit-related genes (CaPFRs) encoding secreted proteins including cell wall proteins, several of which have not been previously described. Transient GFP-fusion assay and an in planta secretion trap were used to validate the secretion of proteins encoded by selected YST clones. In addition, RNA gel blot analyses provided further insights into their expression and regulation during fruit development and ripening. Integrating our data, we conclude that the YST provides a valuable functional genomics tool for the identification of substantial numbers of novel secreted plant proteins that are associated with biological processes, including fruit development and ripening.

60 APPLIED LIFE SCIENCES↗

The interactions of peripheral membrane proteins with biological membranes

The interactions of peripheral proteins with membrane surfaces are critical to many biological processes, including signaling, recognition, membrane trafficking, cell division and cell structure. On a molecular level, peripheral membrane proteins can modulate lipid composition, membrane dynamics and protein-protein interactions. Biochemical and biophysical studies have shown that these interactions are in fact highly complex, dominated by several different types of interactions, and have an interdependent effect on both the protein and membrane. Here we examine three major mechanisms underlying the interactions between peripheral membrane proteins and membranes: electrostatic interactions, hydrophobic interactions, and fatty acid modification of proteins. While experimental approaches continue to provide critical insights into specific interaction mechanisms, emerging bioinformatics resources and tools contribute to a systems-level picture of protein-lipid interactions. Through these recent advances, we begin to understand the pivotal role of protein-lipid interactions underlying complex biological functions at membrane interfaces.

60 APPLIED LIFE SCIENCES↗

Estimation of cerebral blood flow velocity during breath-hold challenge using artificial neural networks

The effect of untreated Obstructive Sleep Apnoea (OSA) on cerebral haemodynamics and CA impairment is an active field of research interest. A breath-hold challenge is usually used in clinical and research settings to simulate cardiovascular and cerebrovascular changes that mimic OSA events. This work utilises temporal arterial oxygen saturation (SpO 2 ) and photoplethysmography (PPG) signals to estimate the temporal cerebral blood flow velocity (CBFv) waveform. Measurements of CBFv, SpO 2 , and PPG, were acquired concurrently from volunteers performing two different protocols of breath-hold challenge in the supine position. Past values of the SpO 2 and PPG signals were used to estimate the current values of CBFv using different permutations and topologies of supervised learning with shallow artificial neural networks (ANNs). Measurements from one protocol were used to train the ANNs and find the optimum topologies, which in turn were tested using the other protocol. Data collected from 10 normotensive, healthy subjects (four females, age 28.5 ± 6.1 years, Body Mass Index (BMI) 24.0 ± 4.7 kg/m 2 ) were used in this study. The results show that different subjects have different optimum topologies for ANNs, thus indicating the effects of inter-subject variability on ANNs. Successfully reconstructed blind waveforms for the same subject group in the second protocol showed a reasonable accuracy of 60–80% estimation compared to the measured waveforms.

59 BASIC BIOLOGICAL SCIENCES↗

Time series anomaly detection in power electronics signals with recurrent and ConvLSTM autoencoders

The anomalies in the high voltage converter modulator (HVCM) remain a major down time for the spallation neutron source facility, that delivers the most intense neutron beam in the world for scientific materials research. In this work, we propose neural network architectures based on Recurrent AutoEncoders (RAE) to detect anomalies ahead of time in the power signals coming from the HVCM. Bi-directional gated recurrent unit, bi-directional long-short term memory (LSTM), and convolutional LSTM (ConvLSTM) are developed, trained, and tested using real experimental signals from the HVCM module. The results show a good performance of the proposed RAE models, achieving precision up to 91%, recall up to 88%, false omission rate as low as 20% (i.e. 80% of the anomalies were detected), and area under the ROC curve up to 0.9. The three RAE models provide very comparable performance, with LSTM showing slightly better performance than GRU and ConvLSTM. The RAE models are benchmarked against other anomaly detection methods, including isolation forest, support vector machine, local outlier factor, feedforward and convolutional autoencoders, and others; showing a better performance. Here, the results of this study demonstrate the promising potential of RAE in anomaly detection for real-world power systems, and for increasing the reliability of the HVCM modules in the spallation neutron source.

42 ENGINEERING↗

Power quality disturbances diagnosis: A 2D densely connected convolutional network framework

The fast and accurate diagnosis of power quality disturbances (PQD) aids in avoiding shutdowns and unnecessary procedures, concerning electric energy distribution systems. As such, a number of techniques have been tested and applied in order to reach this objective. Majority of the techniques applied are two-step based. On the first step, power quality disturbances features are extracted. Second step, considering features extracted, disturbance classification is implemented. Recently, relevant literature has presented data-driven signal processing-based approaches, as deep convolutional neural networks (DCNN), which can implement both processing steps while providing automated recognition of patterns and outliers in data. However, not considered by state-of-art, power quality disturbances are evolving in nature, while all possible regularities might not be represented in the dataset. In this work a 2 Dimension Densely Connected Convolutional Network (2D-DenseNet) framework is presented. Further, a case study with synthetic disturbance events are analyzed. Easy-to-implement formulation, built on the 2D-DenseNet, without hard-to-design parameters, highlight potential aspects for real-life implementation.

42 ENGINEERING↗

An efficient quantum circuit for block encoding a pairing Hamiltonian

We present an efficient quantum circuit for block encoding a pairing Hamiltonian often studied in nuclear physics. Our block encoding scheme does not require mapping the creation and annihilation operators to the Pauli operators and representing the Hamiltonian as a linear combination of unitaries. Instead, we show how to encode the Hamiltonian directly using controlled swap operations. We analyze the gate complexity of the block encoding circuit and show that it scales polynomially with respect to the number of qubits required to represent a quantum state associated with the pairing Hamiltonian. We also show how the block encoding circuit can be combined with the quantum singular value transformation to construct an efficient quantum circuit for approximating the density of states of a pairing Hamiltonian. The techniques presented can be extended to encode more general second-quantized Hamiltonians.

97 MATHEMATICS AND COMPUTING↗

Beam position monitor gate functionality implementation and applications

We introduce a novel technique to implement gate functionality for the beam position monitors (BPM) at the National Synchrotron Light Source II (NSLS-II). The functionality, now implemented in FPGA, allows us to acquire two separated bunch-trains’ synchronized turn-by-turn (TBT) data simultaneously with the NSLS-II in-house developed BPM system. The gated position resolution is improved about 3 times by narrowing the sampling width. Experimentally we demonstrated that the machine lattice could be transparently characterized with the gated TBT data of a short diagnostic bunch-train Cheng et al., 2017; Li et al., 2017. Other applications, for example, precisely characterizing storage ring impedance/wake-field through recording the beam positions of two separated bunch trains has been experimentally demonstrated.

43 PARTICLE ACCELERATORS↗

Microbial proteomics: the quiet revolution

Technological developments in DNA sequencing and their application to study thousands of microbial genomes or even microbial ecosystems still today often make the headlines of general newspapers and scientific journals. These revolutionary changes are hiding another revolution that is unfolding more quietly in the background: the development of microbial proteomics to study genome expression products. It is important to recognize that while DNA sequencing reveals extensive details about the genomic potential of an organism or community, proteomic measurements reveal the functional gene products that are present and operational under specific environmental conditions, and thus perhaps better characterize the critical biomolecules that execute the life processes (enzymes, signaling, structural factors, etc.).

Seraphin, Bertrand↗

Telescope Array Radar (TARA) Observatory for Ultra-High Energy Cosmic Rays

Construction was completed during summer 2013 on the Telescope Array RAdar (TARA) bi-static radar observatory for Ultra-High Energy Cosmic Rays (UHECR). TARA is co-located with the Telescope Array, the largest “conventional” cosmic ray detector in the Northern Hemisphere, in radio-quiet Western Utah. TARA employs an 8 MW Effective Radiated Power (ERP) VHF transmitter and smart receiver system based on a 250 MS/s data acquisition system in an effort to detect the scatter of sounding radiation by UHECR-induced atmospheric ionization. TARA seeks to demonstrate bi-static radar as a useful new remote sensing technique for UHECRs. In this report, we describe the design and performance of the TARA transmitter and receiver systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Front-end ASIC for spectroscopic readout of virtual Frisch-grid CZT bar sensors

Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT) detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at the anode, the cathode and four pad sense electrodes associated with each sensor in a detector array. The ASIC is comprised of 52 channels of which there are 4 cathode channels and 48 channels which can be configured as either anode channels with a baseline of 250 mV or pad sense channels to process induced signals with a baseline of 1.2 V. With a static power dissipation of 3 mW, each channel performs low-noise charge amplification, high-order shaping, peak and timing detection along with analog storage and multiplexing. The overall channel linearity was better than ± 1% with timing resolution down to 700 ps for charges greater than 8 fC in the 3 MeV range. With a 4 × 4 array of 6 mm × 6 mm × 20 mm virtual Frisch-grid bar sensors connected and biased, an electronic resolution of ≈270 e - rms for charges up to 100 fC in the 3.2 MeV range was measured. Spectral measurements obtained with the 3D correction technique demonstrated resolutions of 1.8% FWHM at 238 keV and 0.9% FWHM at 662 keV.

3D↗

Performance of 8 × 8 × 32 and 10 × 10 × 32 mm 3 CdZnTe position-sensitive virtual Frisch-grid detectors for high-energy gamma ray cameras

CdZnTe (CZT) crystals with thicknesses up to 20 mm and diameters up to 75 mm have become available from Redlen Technologies, Inc. for making large-volume gamma-ray detectors. The modified growth and optimized annealing conditions allowed Redlen to minimize the dark current and improve the uniformity of CZT crystals. Two detector designs, pixelated (H3D) and position-sensitive virtual Frisch-grid (VFG), have greatly benefitted from the availability of such big crystals. Encouraging results from testing of 40×40×15 mm 3 pixelated detectors were recently reported by the University of Michigan. In this work, we evaluated the spectroscopic properties of 8×8×32 and 10×10×32 mm 3 crystals configured as position-sensitive VFG detectors. Both digitized waveforms and an analog ASIC were used to read and process the signals from the detectors and test their spectral- and spatial-resolution. The VFG design provides the flexibility to scale-up the dimensions of the detectors for the desired efficiency, while the position information allows for correcting the detectors' response non-uniformity caused by crystal defects and devices geometry, thereby reducing the instrument cost and making them more feasible for emerging applications in gamma-ray astronomy, nonproliferation, portal screening and nuclear safeguards, where large detector arrays are often required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗