Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Resolution improvement of remote sensing data.

Discussion of the theory of a technique for image restoration in the reconstruction of a spatial input scene mapped by a line scanner. Special attention is given to the application of this technique in reducing the data telemetered from the Infrared Scanning Radiometer of the Apollo 17 spacecraft. The technique is based on the theory of splines and uses the results of optimal approximation studies by Colomb (1959), Sard (1967), and Anselone (1968). A recursive algorithm is also developed to improve the reconstruction. The study treats a one-dimensional case, but the treatment can be readily extended to multi-dimensional situations.

Caprihan, A.↗

SU-D-BRE-06: Modeling the Dosimetric Effects of Volumetric and Layer-Based Repainting Strategies in Spot Scanning Proton Treatment Plans

Purpose: To compare multiple repainting techniques as strategies for mitigating the interplay effect in free-breathing, spot scanning proton plans. Methods: An analytic routine modeled three-dimensional dose distributions of pencil-beam proton plans delivered to a moving target. The interplay effect was studied in subsequent calculations by modeling proton delivery from a clinical synchrotron based spot scanning system and respiratory target motion, patterned from surrogate breathing traces from clinical 4DCT scans and normalized to nominal 0.5 and 1 cm amplitudes. Two distinct repainting strategies were modeled. In idealized volumetric repainting, the plan is divided up and delivered multiple times successively, with each instance only delivering a fraction of the total MU. Maximum-MU repainting involves delivering a fixed number of MU per spot and repeating a given energy layer until the prescribed MU are reached. For each of 13 patient breathing traces, the dose was computed for up to four volumetric repaints and an array of maximum-MU values. Delivery strategies were inter-compared based on target coverage, dose homogeneity, and delivery time. Results: Increasing levels of repainting generally improved plan quality and reduced dosimetric variability at the expense of longer delivery time. Motion orthogonal to the scan direction yielded substantially greater dose deviations than motion parallel to the scan direction. For a fixed delivery time, maximum-MU repainting was most effective relative to idealized volumetric repainting at small maximum-MU values. For 1 cm amplitude motion orthogonal to the scan direction, the average homogeneity metric (D5 – D95)[%] of 23.4% was reduced to 7.6% with a 168 s delivery using volumetric repainting compared with 8.7% in 157.2 s for maximum-MU repainting. The associated static target homogeneity metric was 2.5%. Conclusion: Maximum-MU repainting can provide a reasonably effective alternative to volumetric repainting for systems without the capability to switch energies rapidly.

60 APPLIED LIFE SCIENCES↗

Note: Fast imaging of DNA in atomic force microscopy enabled by a local raster scan algorithm

Approaches to high-speed atomic force microscopy typically involve some combination of novel mechanical design to increase the physical bandwidth and advanced controllers to take maximum advantage of the physical capabilities. For certain classes of samples, however, imaging time can be reduced on standard instruments by reducing the amount of measurement that is performed to image the sample. One such technique is the local raster scan algorithm, developed for imaging of string-like samples. Here we provide experimental results on the use of this technique to image DNA samples, demonstrating the efficacy of the scheme and illustrating the order-of-magnitude improvement in imaging time that it provides.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting brain tumor in computed tomography images using Markov random fields and fuzzy C-means clustering techniques

Brain tumors, are an abnormal growth of tissues in the brain. They may arise in people of any age. They must be detected early, diagnosed accurately, monitored carefully, and treated effectively in order to optimize patient outcomes regarding both survival and quality of life. Manual segmentation of brain tumors from CT scan images is a challenging and time consuming task. Size and location accurate detection of brain tumor plays a vital role in the successful diagnosis and treatment of tumors. Brain tumor detection is considered a challenging mission in medical image processing. The aim of this paper is to introduce a scheme for tumor detection in CT scan images using two different techniques Hidden Markov Random Fields (HMRF) and Fuzzy C-means (FCM). The proposed method has been developed in this research in order to construct hybrid method between (HMRF) and threshold. These methods have been applied on 4 different patient data sets. The result of comparison among these methods shows that the proposed method gives good results for brain tissue detection, and is more robust and effective compared with (FCM) techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Field evaluation of remote wind sensing technologies: Shore-based and buoy mounted LIDAR systems

In developing a national energy strategy, the United States has a number of objectives, including increasing economic growth, improving environmental quality, and enhancing national energy security. Wind power contributes to these objectives through the deployment of clean, affordable and reliable domestic energy. To achieve U.S. wind generation objectives, the Wind and Water Power Program within the Department of Energy’s (DOE) Office of Energy Efficiency and Renewable Energy (EERE) instituted the U.S. Offshore Wind: Removing Market Barriers Program in FY 2011. Accurate and comprehensive information on offshore wind resource characteristics across a range of spatial and temporal scales is one market barrier that needs to be addressed through advanced research in remote sensing technologies. There is a pressing need for reliable offshore wind-speed measurements to assess the availability of the potential wind energy resource in terms of power production and to identify any frequently occurring spatial variability in the offshore wind resource that may impact the operational reliability and lifetime of wind turbines and their components and to provide a verification program to validate the “bankability” of the output of these alternative technologies for use by finance institutions for the financing of offshore wind farm construction. The application of emerging remote sensing technologies is viewed as a means to cost-effectively meet the data needs of the offshore wind industry. In particular, scanning and buoy mounted LIDAR have been proposed as a means to obtain accurate offshore wind data at multiple locations without the high cost and regulatory hurdles associated with the construction of offshore meteorological towers. However; before these remote sensing technologies can be accepted the validity of the measured data must be evaluated to ensure their accuracy. The proposed research will establish a unique coastal ocean test-bed in the Mid-Atlantic for the evaluation of LIDAR-based wind measurement systems to validate the accuracy of remotely measured wind data in marine applications. Specifically, the test-bed will be utilized to systematically evaluate the capability of emerging scanning LIDAR and buoy mounted vertically profiling LIDAR by: (1) Evaluating a fixed scanning LIDAR against land-based 50 and 60 meter high meteorological masts fitted with research quality cup-vane and/or sonic anemometers; (2) Evaluating a buoy mounted vertically profiling LIDAR fixed on land and floating in a sheltered bay against a co-located 60 meter high meteorological mast fitted with a research quality cup-vane and/or sonic anemometers and the fixed scanning LIDAR; and (3) Offshore field evaluation of both LIDAR platforms through a comparison of the fixed scanning LIDAR data and data obtained by the buoy mounted LIDAR located 10 miles offshore. The proposed research will systematically validate Light Detection and Ranging (LIDAR) based wind measurement systems and assess the temporal and spatial variability of the offshore wind resource in the Mid-Atlantic east of New Jersey. The goal of the proposed project is to address the technical and commercial challenges of the offshore wind energy industry by validating and assessing cost-effective, over ocean wind resource characterization technologies. The objective is to systematically evaluate the capability of both scanning and vertically profiling LIDARs to accurately measure 3D wind fields through comparison with fixed met masts and intercomparison among LIDAR platforms. Once validated, data collected by both buoy mounted vertically profiling LIDARs and shore-based, pulsed horizontally scanning LIDARs can be used to accurately assess offshore wind resources and to quantify the spatial and temporal variability in the offshore wind fields. One of the fundamental research questions to be addressed in phase 1 is the assessment of various measurement and data processing schemes to retrieve accurate wind vectors in the marine environment over large sampling ranges (10 to 12 km) and varying atmospheric aerosol levels. Atmospheric conditions and aerosol content within the coastal ocean region of the Mid-Atlantic seaboard of the US can vary significantly over short time periods in response to frontal passages and extratropical and tropical low pressure system passage offshore of the coast. Since aerosols provide the scattering medium for the determination of LIDAR Doppler shifts in the atmosphere the accuracy and range of LIDAR derived velocity measurements as a function of variation in aerosol content in the marine environment is a key research question to be addressed. In phase 1, it is desired to capture as much variation in atmospheric conditions and aerosol content as possible. To this end, collocated measurements of LIDAR and standard anemometer wind fields will be captured by the project PIs over all four seasons and during specific events (e.g., coastal low pressure system passage) in year 1. Additionally, since the meteorological masts are permanent structures, additional events can be captured over the three year duration of the field research project. All research instruments are owned by Fishermen’s Energy and made available to the PIs though a lease agreement as part of the DOE grant. Energy Fishermen’s Energy will be responsible for the operation and maintenance of the scanning LIDAR and met mast anemometers. On a daily basis, environmental data and systems performance indicators will be transmitted from each measurement station to the Fishermen’s project team consisting of both in-house personnel and equipment manufacturer engineers. Data sets include compiled LIDAR files as well as data sets from ancillary sensors. Diagnostic parameters to be monitored include standard deviations of measured values, battery levels and charging systems output, and the operational status. Once data have been confirmed as complete and reliable, files will be transferred to the Garrad Hassan (a subcontractor to Fishermen’s Energy) for incorporation in to the validation database, which is accessible to other scientific team members. Data collection times and durations will be determined by the PI and Co-PIs in consultation with instrument engineers to ensure the capture of data representative of the expected range of mid-Atlantic atmospheric conditions (e.g., temperature, moisture, coastal low pressure systems, tropical systems, rain, snow, fog). The collection and processing of the data is a function of site specific measurement requirements (Kelley et.al. 2007; Hannon et.al. 2008). To determine the optimal profiles of wind speed and direction from the LIDAR radial velocities as a function of azimuth angle, rigorous estimates of the bias and random error of each radial velocity estimate are required. Lockheed Martin Coherent Technologies, Inc., under contract with Fishermen’s Energy, will provide analyses of raw and processed data using various scan patterns to determine optimal performance settings for the pulsed scanning LIDAR. Once optimized, appropriate processing and analyses techniques will be evaluated by Garrad Hassan for use in validating the accuracy of the LIDAR wind field measurements against the standard anemometer measurements from the meteorological masts. The most attractive capability of the scanning LIDAR is the ability to provide high spatial resolution observations in a three-dimensional volume which provides superior statistical accuracy due to the large number of samples obtained. Each radial scan provides measurements in 100 range gates over a distance of 10 to 12 km at an update rate of 5 to 10 Hz and rotation of 2.5° per second. Each rotation at a fixed azimuth requires 2.4 minutes. Depending on the number of azimuths desired a complete scan can take up to 10 minutes or longer to complete. Once collected the radial velocities are processed to produce vector wind velocity estimates based on a set of data distributed in angle and range around points of interest, typically a standard grid within the radial wind map. To calculate wind vectors over a limited spatial area of interest for the comparison of data with other measurement platforms a localized least-squares approach has been applied by Hannon et.al. (2008) and a Variation Assimilation (VAR) processing technique has been applied by Chan and al Assimilation (VAR) processing technique has been applied by Chan and Shao (2006). Additionally, Kelley et.al. (2007) applied a “stare” technique that fixed a scanning LIDAR in both azimuth and elevation angles to measure over collocated sampling volumes of the LIDAR and a 3D sonic anemometer mounted to a fixed mast. Although the stare technique is limited to wind directions aligned with the sampling radial of the LIDAR, it does provide a direct comparison of sampling volumes. Each of the processing techniques described above (and possibly others) will be evaluated to determine the validity of the LIDAR derived wind fields in the marine environment. Numerical methods such as linear regression and comparison of probability density functions of wind fields measured by each instrument platform will be used to assess the processing techniques. Linear regression has the advantage of directly evaluating corresponding pairs of wind data measured by each instrument and can lend insight into deviations and bias between instruments as a function of wind speed. Assessment of the coherency between the probability density function of the wind measured by each instrument provides insight into processes that may not be accurately resolved by each instrument at specific frequencies. Once processed and assessed the most appropriate technique will be utilized to provide valid wind measurements from the pulsed scanning LIDAR. A detailed analysis of the measurement data from the LIDAR and the three meteorological towers and comparison of the coastal wind characteristics from the different systems will be performed by the CO_PI at NREL. This analysis will evaluate how the WT LIDAR performance and measurement of the wind characteristics vary with distance from the LIDAR and by atmospheric conditions; using the tower measurements at different distances (4.8, 9.6, and 19 km) from the LIDAR as a reference. The comparative analysis will include, to the extent possible, evaluation of parameters such as wind speed and direction distributions, wind shear, turbulence intensity and their variations by atmospheric conditions, month or season, and time of day.

17 WIND ENERGY↗

Effective Defect Detection Using Instance Segmentation for NDI

Ultrasonic testing is a common Non-Destructive Inspection (NDI) method used in aerospace manufacturing. However, the complexity and size of the ultrasonic scans make it challenging to identify defects through visual inspection or machine learning models. Using computer vision techniques to identify defects from ultrasonic scans is an evolving research area. In this study, we used instance segmentation to identify the presence of defects in the ultrasonic scan images of composite panels that are representative of real components manufactured in aerospace. We used two models based on Mask- RCNN (Detectron 2) and YOLO 11 respectively. Additionally, we implemented a simple statistical pre-processing technique that reduces the burden of requiring custom-tailored pre-processing techniques. Our study demonstrates the feasibility and effectiveness of using instance segmentation in the NDI pipeline by significantly reducing data pre-processing time, inspection time, and overall costs.

computer vision techniques↗

Recent developments in CID imaging

Readout of CID imaging arrays was first performed by injecting and detecting the signal charge from each sensing site in sequence. A new readout method, termed parallel injection, has been developed in which the functions of signal charge detection and injection have been separated. The level of signal charge at each sensing site is detected during a line scan, and during the line retrace interval, all charge in the selected line is injected. The parallel injection technique is well adapted to TV scan formats in that the signal is read out at high speed, line by line. A 244 line by 248 element TV compatible imager, employing this technique and including an on chip preamplifier, has been constructed and operation demonstrated.

Michon, G. J.↗

CFD Modeling and Image Analysis of Exhaled Aerosols due to a Growing Bronchial Tumor: towards Non-Invasive Diagnosis and Treatment of Respiratory Obstructive Diseases

Diagnosis and prognosis of tumorigenesis are generally performed with CT, PET, or biopsy. Such methods are accurate, but have the limitations of high cost and posing additional health risks to patients. In this study, we introduce an alternative computer aided diagnostic tool that can locate malignant sites caused by tumorigenesis in a non-invasive and low-cost way. Our hypothesis is that exhaled aerosol distribution is unique to lung structure and is sensitive to airway structure vari-ations. With appropriate approaches, it is possible to locate the disease site, determine the disease severity, and subsequently formulate a targeted drug delivery plan to treat the disease. This study numerically evaluated the feasibility of the proposed breath test in an image-based lung model with varying pathological stages of a bronchial squamous tumor. Large eddy simulations and a Lagran-gian tracking approach were used to model respiratory airflows and aerosol dynamics. Respira-tions of tracer aerosols of 1 µm at a flow rate of 20 L/min were simulated, with the distributions of exhaled aerosols recorded on a filter at the mouth exit. Aerosol patterns were quantified with multiple analytical techniques such as concentration disparity, spatial scanning and fractal analysis. We demonstrated that a growing bronchial tumor induced notable variations in both the airflow and exhaled aerosol distribution. These variations became more apparent with increasing tumor severity. The exhaled aerosols exhibited distinctive pattern parameters such as spatial probability, fractal dimension, and multifractal spectrum. Results of this study show that morphometric measures of the exhaled aerosol pattern can be used to detect and monitor the pathological states of respiratory diseases in the upper airway. The proposed breath test also has the potential to locate the site of the disease, which is critical in developing a personalized, site-specific drug de-livery protocol.

Aerosol breath test↗

Comparison of column water vapor measurements using downward-looking near-infrared and infrared imaging systems and upward-looking microwave radiometers

Remote soundings of precipitable water vapor from three systems are compared with each other and with ground truth from radiosondes. Ancillary data from a mesoscale network of surface observing stations and from wind-profiling radars are also used in the analysis. The three remote-sounding techniques are: (a) a reflectance technique using spectral data collected by the Airborne Visible-Infrared Imaging Spectrometer; (b) an emission technique using Visible-Infrared Spin Scan Radiometer Atmospheric Sounder (VAS) data acquired from the NOAA's GOES; and (c) a microwave technique using data from a limited network of three ground-based dual-channel microwave radiometers. The data were taken over the Front Range of eastern Colorado on 22-23 March 1990. The generally small differences between the three types of remote-sounding measurements are consistent with the horizontal and temporal resolutions of the instruments. The microwave and optical reflectance measurements agreed to within 0.1 cm; comparisons of the microwave data with radiosondes were also either as good or explainable. The largest differences between the VAS and the microwave radiometer at Elbert were between 0.4 and 0.5 cm and appear to be due to variable terrain within the satellite footprint.

Gao, Bo-Cai↗

Near-field terahertz nonlinear optics with blue light

Abstract The coupling of terahertz optical techniques to scattering-type scanning near-field microscopy (s-SNOM) has recently emerged as a valuable new paradigm for probing the properties of semiconductors and other materials on the nanoscale. Researchers have demonstrated a family of related techniques, including terahertz nanoscopy (elastic scattering, based on linear optics), time-resolved methods, and nanoscale terahertz emission spectroscopy. However, as with nearly all examples of s-SNOM since the technique’s inception in the mid-1990s, the wavelength of the optical source coupled to the near-field tip is long, usually at energies of 2.5 eV or less. Challenges in coupling of shorter wavelengths (i.e., blue light) to the nanotip has greatly inhibited the study of nanoscale phenomena in wide bandgap materials such as Si and GaN. Here, we describe the first experimental demonstration of s-SNOM using blue light. With femtosecond pulses at 410 nm, we generate terahertz pulses directly from bulk silicon, spatially resolved with nanoscale resolution, and show that these signals provide spectroscopic information that cannot be obtained using near-infrared excitation. We develop a new theoretical framework to account for this nonlinear interaction, which enables accurate extraction of material parameters. This work establishes a new realm of possibilities for the study of technologically relevant wide-bandgap materials using s-SNOM methods.

47 OTHER INSTRUMENTATION↗

Analysis of the Mutual Inductance between Two Parallel Plates for the Detection of Surface Flaws

There has recently been much effort behind the development of NDE methods applicable to the detection of surface/subsurface flaws in thin metallic structures with a rapid scan capability. One such method, an electromagnetic technique using a current-sheet parallel to the surface of a specimen in order to induce eddy current flow shows a high potential for satisfying the rapid scan requirement stated above. The technique is based on the detection of flaw-induced magnetic field components normal to the specimen surface by an appropriate detection mechanism positioned above the current-sheet as shown schematically in Fig. 1. As indicated in this figure, the current-sheet separates the source of the normal magnetic field components from the detector in such a way that the electric and magnetic properties of the current-sheet can be a major factor affecting the strength of the detected signals. The purpose of the present study is, therefore, to perform a detailed investigation on the effect of the material properties of the current-sheet on the detected signal strength and to establish a simple theoretical model for the detection mechanism.

Namking, M.↗

Multi-Scale Lithofacies and Chemostratigraphic Analysis of Two Middle Devonian Marcellus Shale Wells in Northern West Virginia, USA

The Marcellus Shale Energy and Environmental Laboratory (MSEEL) consists of two project areas within the dry gas producing region of the Marcellus shale play in Monongalia County, West Virginia. MSEEL is a collaborative field project led by West Virginia University, with Northeast Natural Energy LLC, several industrial partners, and sponsored by the US Department of Energy National Energy Technology Laboratory. The study areas are drilled approximately 8.5 miles apart to better understand the vertical and lateral changes in stratigraphy over a short distance. Two vertical pilot wells, MIP-3H and Boggess 17H were drilled in the fall of 2015 and spring of 2019, respectively. Core was recovered from the MIP-3H (API: 47-061-01707-00-00) 112 feet (34m) between depths of 7445 to 7557 feet, and from the Boggess 17H (API: 47-061-01812-00-00) 139 feet (42m) between depths of 7908 and 8012 ft. A full suite of triple combo (gamma ray, neutron, density logs), image logs, and advanced logging tools were run in both wells and calibrated to core analysis. Core analysis includes medical computed tomography (CT) scans, mineralogy and chemostratigraphy determined from handheld X-Ray fluorescence (hhXRF) and X-Ray powder diffraction (XRD) measurements, and determination of total organic content (TOC). Lithofacies were determined at core-scale using traditional core description techniques and medical CT-scan images. Log-scale facies are based on mineralogy and TOC data and developed using petrophysical logging data calibrated to core data (XRD and pyrolysis data). Chemostratigraphic analysis utilized hhXRF data to determine the major and trace element trends in the cores. In the two wells six shale lithofacies were recognized at the core and log scale. Both wells show organic-rich facies (TOC > 6.5%) primarily in the middle and lower Marcellus, with a slight decrease in thickness of this interval in the Boggess 17H. This interval is interpreted as an increase in paleo-productivity (increased Ni, Zn, and V), decreased sedimentation (decreased detrital proxies), and anoxic to euxinic conditions (increased Mo and chalcophile elements). Paleo-redox conditions in both wells are dynamic throughout deposition transitioning between euxinic/anoxic to dysoxic/oxic. This trend is seen through elemental proxies and calcite/pyrite concretion distributions.

03 NATURAL GAS↗

Quantitative thermal diffusivity measurements of composites

A remote radiometric technique for making quantitative thermal diffusivity measurements is described. The technique was designed to make assessments of the structural integrity of large composite parts, such as wings, and can be performed at field sites. In the measurement technique, a CO2 laser beam is scanned using two orthogonal servo-controlled deflecting mirrors. An infrared imager, whose scanning mirrors oscillate in the vertical and the horizontal directions, is used as the detector. The analysis technique used to extract the diffusivity from these images is based on a thin infinite plate assumption, which requires waiting a given period of time for the temperature to equilibrate throughout the thickness of the sample. The technique is shown to be accurate to within two percent for values of the order of those for composite diffusivities, and to be insensitive to convection losses.

Heath, D. M.↗

Yttria-Stabilized Zirconia Aided Electrochemical Investigation on Ferric Ions in Mixed Molten Calcium and Sodium Chlorides

Electrolytic reduction of dissolved iron oxide to metal iron in molten salts with an inert anode is an alternative short route for steelmaking without CO{sub 2} emissions. A novel and simple integrated yttria-stabilized zirconia (YSZ) cell was constructed from a YSZ tube with a closed end. The YSZ tube played multiple functions, including the container for the molten salts, the solid electrolyte membrane in the O{sup 2−}|YSZ|Pt|O{sub 2} (air) reference electrode (RE), and the solid electrolyte membrane between the working and counter electrodes (WE and CE). Electrochemical behavior of ferric ions (Fe{sup 3+}) that were formed by dissolution of 0.5 wt pct Fe{sub 2}O{sub 3} in the molten CaCl{sub 2}-NaCl eutectic mixture was investigated on a Pt WE at 1273 K by various electrochemical techniques including cyclic voltammetry, linear scan voltammetry, square wave voltammetry, chronopotentiometry, chronoamperometry, and potentiostatic electrolysis. Analysis of the mechanism of electrode reactions was further assisted by scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction. Some electrochemical parameters were obtained, including the number of exchanged electrons and the diffusion coefficient of ferric ions in the mixed molten salts. The results from various electrochemical techniques are in good agreement with each other, and show that the electrochemical reduction of Fe{sup 3+} to Fe in the molten salt mixture could be a single three-electron transfer step and diffusion-controlled reaction that was also possibly reversible. This work may form the foundation for extraction of iron and alloys from molten salts and also provide a stable O{sup 2−}|YSZ|Pt|O{sub 2} (air) RE with wide applicability for investigation on electrochemical properties of other electroactive metal oxides in molten salts.

36 MATERIALS SCIENCE↗

Improved high-resolution mapping of phase-matching conditions in second-order nonlinear crystals via imaging

Large-aperture nonlinear crystals for frequency conversion and parametric amplification exhibit spatial variations in phase-matching conditions, which affect the performance of high-power laser systems. We demonstrate significant improvements in speed and resolution to a technique that spatially maps these phase-matching conditions using imaging of the beam resulting from detuned second-harmonic generation. The phase-matching conditions at the pyramidal sector boundary of partially deuterated potassium dihydrogen phosphate (DKDP) are mapped with sub-0.1-mm resolution. We examine the effect of further increases in scan rate on the precision of the technique and demonstrate a scan rate of 0.8 cm 2 per minute at the aforementioned resolution.

Wampler, R. [Univ. of Rochester, NY (United States↗