Search NASA⌕ Search

SEARCH · Search NASA

Results for “Smoothing methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

HostSub_GP: Precise Galaxy Background Subtraction in Transient Long-slit Spectroscopy with Gaussian Processes

We present a novel host galaxy subtraction technique in long-slit spectroscopy for extragalactic transients. Unlike classic methods which generally estimate the background using simple interpolation of local galaxy flux in the 2D spectrum, our approach leverages multi-band archival images of the host galaxies to model the background emission from the galaxy in the 2D spectrum. Such imaging encodes the wavelength-dependent galaxy profile along the slit, and is readily accessible through wide-field imaging surveys. We construct a smooth prior for the 2D galaxy profile with a Gaussian process (GP) based on these reference images, and use another GP to model the correlated deviations from the prior in the observed spectrum. This enables accurate inference of the galaxy flux blended with the transient. On synthetic long-slit data of a spiral galaxy extracted from a Multi Unit Spectroscopic Explorer hyper-spectral cube, the GP method remains robust as long as the host galaxy is spatially resolved and consistently outperforms classic methods. We apply the method to archival Keck spectra of two real transients, SN 2019eix and AT 2019qiz, to further demonstrate how the method uniquely recovers weak spectral features amid strong galaxy contamination, enabling refined constraints on the properties of both transients. We have released the software implementation, HostSub_GP, a scalable toolkit that leverages JAX, with an MIT license.

79 ASTRONOMY AND ASTROPHYSICS↗

Features of molecular beam epitaxy of the GaN (0001) and GaN (0001-bar) layers with the use of different methods of activation of nitrogen

The results of comparative studies of the growth kinetics of the GaN layers of different polarity during ammonia molecular beam epitaxy and plasma-assisted molecular beam epitaxy (PA MBE) of nitrogen with the use of sapphire substrates and GaN(0001-bar)/c-Al{sub 2}O{sub 3} templates grown by gas-phase epitaxy from metalorganic compounds are presented. The possibility is shown of obtaining the GaN layers with an atomically smooth surface during molecular beam epitaxy with plasma activation of nitrogen. For this purpose, it is suggested to carry out the growth in conditions enriched with metal near the mode of formation of the Ga drops at a temperature close to the decomposition temperature of GaN (TS {approx} 760 deg. C). The conclusion is made that an increase in the growth temperature positively affects the structural, optical, and electrical properties of the GaN (0001-bar) layers. A high quality of the GaN (0001) films grown by the PA MBE method at a low temperature of {approx}700 deg. C on the GaN/c-Al{sub 2}O{sub 3} templates is shown.

36 MATERIALS SCIENCE↗

A novel synthesis of micrometer silica hollow sphere

Silica microcapsules (hollow spheres) were synthesized successfully by a novel CTAB-stabilized water/oil emulsion system mediated hydrothermal method. The addition of urea to a solution of aqueous phase was an essential step of the simple synthetic procedure of silica hollow spheres, which leads to the formation of silica hollow spheres with smooth shell during hydrothermal process. The intact hollow spheres were obtained by washing the as-synthesized solid products with distilled water to remove the organic components. A large amount of silanol groups were retained in the hollow spheres by this facile route without calcination. The morphologies and optical properties of the product were characterized by transmission electron microscopy, scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy. Furthermore, on the basis of a series of SEM observations, phenomenological elucidation of a mechanism for the growth of the silica hollow spheres has been presented.

36 MATERIALS SCIENCE↗

Manifold Sampling for Optimizing Nonsmooth Nonconvex Compositions

Here we propose a manifold sampling algorithm for minimizing a nonsmooth composition $f= h\circ F$, where we assume $h$ is nonsmooth and may be inexpensively computed in closed form and $F$ is smooth but its Jacobian may not be available. We additionally assume that the composition $h\circ F$ defines a continuous selection. Manifold sampling algorithms can be classified as model-based derivative-free methods, in that models of $F$ are combined with particularly sampled information about $h$ to yield local models for use within a trust-region framework. We demonstrate that cluster points of the sequence of iterates generated by the manifold sampling algorithm are Clarke stationary. We consider the tractability of three particular subproblems generated by the manifold sampling algorithm and the extent to which inexact solutions to these subproblems may be tolerated. Numerical results demonstrate that manifold sampling as a derivative-free algorithm is competitive with state-of-the-art algorithms for nonsmooth optimization that utilize first-order information about $f$.

97 MATHEMATICS AND COMPUTING↗

Extracting the Breakout Distance from the ECOT Trajectories: Gaussian Process Regression Approach

Enhanced Corner Turning (ECOT) experiments provide an important metric of performance of high explosive (HE) formulations. The breakout distance is a single scalar value that characterizes the corner turning efficiency of an HE. Extracting the breakout distance from the raw ECOT results, whether experimental or simulated, is a conceptually straightforward procedure which, however, is non-unique, especially in the presence of noise. More specifically, this procedure involves numerical smoothing and selecting particular values for parameters of this smoothing introduces human bias. In this work, we propose to use the Gaussian process regression to analyze ECOT results. This analysis involves the effective smoothing of the data, thus allowing for accurate extraction of the breakout distance. Most importantly, the parameters of this smoothing can be inferred from the ECOT data itself, rendering the approach effectively parameter-free and thus diminishing the human bias. An additional benefit of the Gaussian process regression, being a statistical inference method, is that not just the value of the breakout distance, but also its confidence interval can be extracted from the data. This report introduces the Gaussian process regression, as applied to ECOT, and demonstrates its usefulness by extracting the breakout distances for a selection of experimental and simulated data.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Histopomorphic Evaluation of Radiofrequency Mediated Débridement Chondroplasty

The use of radiofrequency devices has become widespread for surgical ablation procedures. When ablation devices have been deployed in treatment settings requiring tissue preservation like débridement chondroplasty, adoption has been limited due to the collateral damage caused by these devices in healthy tissue surrounding the treatment site. Ex vivo radiofrequency mediated débridement chondroplasty was performed on osteochondral specimens demonstrating surface fibrillation obtained from patients undergoing knee total joint replacement. Three radiofrequency systems designed to perform débridement chondroplasty were tested each demonstrating different energy delivery methods: monopolar ablation, bipolar ablation, and non-ablation energy. Treatment outcomes were compared with control specimens as to clinical endpoint and histopomorphic characteristics. Fibrillated cartilage was removed in all specimens; however, the residual tissue remaining at the treatment site displayed significantly different characteristics attributable to radiofrequency energy delivery method. Systems that delivered ablation-based energies caused tissue necrosis and collateral damage at the treatment site including corruption of cartilage Superficial and Transitional Zones; whereas, the non-ablation system created a smooth articular surface with Superficial Zone maintenance and without chondrocyte death or tissue necrosis. The mechanism of radiofrequency energy deposition upon tissues is particularly important in treatment settings requiring tissue preservation. Ablation-based device systems can cause a worsened state of articular cartilage from that of pre-treatment. Non-ablation energy can be successful in modifying/preconditioning tissue during débridement chondroplasty without causing collateral damage. Utilizing a non-ablation radiofrequency system provides the ability to perform successful débridement chondroplasty without causing additional articular cartilage tissue damage and may allow for other cartilage intervention success.

59 BASIC BIOLOGICAL SCIENCES↗

An Improved Method to Measure the Cosmic Curvature

In this paper, we propose an improved model-independent method to constrain the cosmic curvature by combining the most recent Hubble parameter H ( z ) and supernovae Ia (SNe Ia) data. Based on the H ( z ) data, we first use the model-independent smoothing technique, Gaussian processes, to construct a distance modulus μ {sub H} ( z ), which is susceptible to the cosmic curvature parameter Ω{sub k}. In contrary to previous studies, the light-curve-fitting parameters, which account for the distance estimation of SN (μ {sub SN}( z )), are set free to investigate whether Ω {sub k} has a dependence on them. By comparing μ {sub H} ( z ) to μ {sub SN}(z), we put limits on Ω {sub k}. Our results confirm that Ω {sub k} is independent of the SN light-curve parameters. Moreover, we show that the measured Ω {sub k} is in good agreement with zero cosmic curvature, implying that there is no significant deviation from a flat universe at the current observational data level. We also test the influence of different H(z) samples and different Hubble constant H {sub 0} values, finding that different H(z) samples do not have a significant impact on the constraints. However, different H {sub 0} priors can affect the constraints of Ω {sub k} to some degree. The prior of H {sub 0} = 73.24 ± 1.74 km s{sup −1} Mpc{sup −1} gives a value of Ω {sub k}, a little bit above the 1 σ confidence level away from 0, but H{sub 0} = 69.6 ± 0.7 km s{sup −1} Mpc{sup −1} gives it below 1 σ .

79 ASTRONOMY AND ASTROPHYSICS↗

Particle control near reticle and optics using showerhead

A method and an apparatus to protect a reticle against particles and chemicals in an actinic EUV reticle inspection tool are presented. The method and apparatus utilizes a pair of porous metal diffusers in the form of showerheads to provide a continual flow of clean gas. The main showerhead bathes the reticle surface to be inspected in smoothly flowing, low pressure gas, isolating it from particles coming from surrounding volumes. The secondary showerhead faces away from the reticle and toward the EUV illumination and projection optics, supplying them with purge gas while at the same time creating a buffer zone that is kept free of any particle contamination originating from those optics.

36 MATERIALS SCIENCE↗

Using spatio-temporal graph neural networks to estimate fleet-wide photovoltaic performance degradation patterns

Accurate estimation of photovoltaic (PV) system performance is crucial for determining its feasibility as a power generation technology and financial asset. PV-based energy solutions offer a viable alternative to traditional energy resources due to their superior Levelized Cost of Energy (LCOE). A significant challenge in assessing the LCOE of PV systems lies in understanding the Performance Loss Rate (PLR) for large fleets of PV systems. Estimating the PLR of PV systems becomes increasingly important in the rapidly growing PV industry. Precise PLR estimation benefits PV users by providing real-time monitoring of PV module performance, while explainable PLR estimation assists PV manufacturers in studying and enhancing the performance of their products. However, traditional PLR estimation methods based on statistical models have notable drawbacks. Firstly, they require user knowledge and decision-making. Secondly, they fail to leverage spatial coherence for fleet-level analysis. Additionally, these methods inherently assume the linearity of degradation, which is not representative of real world degradation. To overcome these challenges, we propose a novel graph deep learning-based decomposition method called the Spatio-Temporal Graph Neural Network for fleet-level PLR estimation (PV-stGNN-PLR). PV-stGNN-PLR decomposes the power timeseries data into aging and fluctuation components, utilizing the aging component to estimate PLR. PV-stGNN-PLR exploits spatial and temporal coherence to derive PLR estimation for all systems in a fleet and imposes flatness and smoothness regularization in loss function to ensure the successful disentanglement between aging and fluctuation. We have evaluated PV-stGNN-PLR on three simulated PV datasets consisting of 100 inverters from 5 sites. Experimental results show that PV-stGNN-PLR obtains a reduction of 33.9% and 35.1% on average in Mean Absolute Percent Error (MAPE) and Euclidean Distance (ED) in PLR degradation pattern estimation compared to the state-of-the-art PLR estimation methods.

14 SOLAR ENERGY↗

Combining Spectroscopic Ellipsometry with Transmission Spectroscopy to Derive Accurate Optical Constants for Organic Materials

A method for deriving the optical constants of organic powdered materials in the mid-infrared spectral range is introduced using variable angle spectroscopic ellipsometry and transmission spectroscopy. The approach uses pressed pellets of the powder and is applied to organic solids, which have both strong and weak infrared absorption features. Many powders have significant voids and do not press into smooth, homogenous pellets. To account for pellet non-idealities and to accurately measure both n and k, three different forms of pellets were pressed and measured: A pure analyte pellet, a mixed analyte/KBr pellet with a large analyte percentage, and a KBr transmission pellet with only a small analyte percentage. Using all three pellets in a multi-sample analysis involving both ellipsometric and transmission data, the complex refractive index (n/k) values can be derived for many organic compounds. This method is illustrated to calculate the optical constants for anhydrous lactose from 6000-400 cm-1. The transmission measurements improve the spectral fitting of weak absorption features, and the multi-sample analysis enables a better determination of the significant void space that is present in the pure pellet, leading to lower values for both n and k if not properly accounted for in the multi-oscillator model used to fit the ellipsometric data.

Optical constants, refractive index, extinction co↗

Physics‐Informed Machine Learning Method for Large‐Scale Data Assimilation Problems

Abstract We develop a physics‐informed machine learning approach for large‐scale data assimilation and parameter estimation and apply it for estimating transmissivity and hydraulic head in the two‐dimensional steady‐state subsurface flow model of the Hanford Site given synthetic measurements of said variables. In our approach, we extend the physics‐informed conditional Karhunen‐Loéve expansion (PICKLE) method to modeling subsurface flow with unknown flux (Neumann) and varying head (time‐dependent Dirichlet) boundary conditions. We demonstrate that the PICKLE method is comparable in accuracy with the standard maximum a posteriori (MAP) method, but is significantly faster than MAP for large‐scale problems. Both methods use a mesh to discretize the computational domain. In MAP, the parameters and states are discretized on the mesh; therefore, the size of the MAP parameter estimation problem directly depends on the mesh size. In PICKLE, the mesh is used to evaluate the residuals of the governing equation, while the parameters and states are approximated by the truncated conditional Karhunen‐Loéve expansions with the number of parameters controlled by the smoothness of the parameter and state fields, and not by the mesh size. For a considered example, we demonstrate that the computational cost of PICKLE increases near linearly (as N 1.15 ) with the number of grid nodes N , while that of MAP increases much faster (as N 3.28 ). We also show that once trained for one set of Dirichlet boundary conditions (i.e., one river stage), the PICKLE method provides accurate estimates of the hydraulic head for any value of the Dirichlet boundary conditions (i.e., for any river stage).

97 MATHEMATICS AND COMPUTING↗

Onset dynamics of air-water menisci on rock fracture surfaces

Information on menisci dynamics and equilibrium contact angles, θ e , is needed for modeling multiphase flow of fluids in geologic formations. The wettability of fracture faces is relevant to applications such as waterflooding in enhanced oil recovery and evaluation of caprock integrity for geologic carbon sequestration. We investigated the vertical capillary rise of air-water menisci on exposed fracture faces for a sandstone, a shale, and three granites. The experimental design approximated that employed in the Wilhelmy plate method. Replicate fracture faces were prepared by fracturing cylindrical rock cores using the Brazilian method and splitting the fractured cores apart along their fracture planes. Meniscus onset was imaged from a cross-sectional perspective using dynamic neutron radiography, and quantified with change point analysis. An existing model for meniscus onset fitted the experimental data very well (median R 2 = 0.96). Capillary rise was typified by t 2/3 scaling (where t is time), followed by a constant equilibrium height, z e . The average time taken for the menisci to reach z e was 0.39 s, with no differences between rock types. The menisci achieved a greater vertical extent on the fracture faces of the sedimentary rocks as compared to those of the granites. Apparent θ e values were calculated from the best fit estimates of z e using the Wilhelmy plate equation for a smooth and planar vertical surface. Despite the fractal roughness of some of the fracture faces, there was a significant linear relationship (R 2 = 0.80) between the apparent θ e values and intrinsic θ e values measured on polished surfaces of the same rocks using the sessile drop method. The regression equation indicated the apparent θ e values were consistently greater than the intrinsic values. This overestimation may be due to averaging of pixels at the air-water-solid interface, a required step in the image analysis. Further exploration of the range of applicability and measurement accuracy of this proposed new technique would be valuable.

58 GEOSCIENCES↗

DENSITY ESTIMATION FOR PROJECTED EXOPLANET QUANTITIES

Exoplanet searches using radial velocity (RV) and microlensing (ML) produce samples of 'projected' mass and orbital radius, respectively. We present a new method for estimating the probability density distribution (density) of the unprojected quantity from such samples. For a sample of n data values, the method involves solving n simultaneous linear equations to determine the weights of delta functions for the raw, unsmoothed density of the unprojected quantity that cause the associated cumulative distribution function (CDF) of the projected quantity to exactly reproduce the empirical CDF of the sample at the locations of the n data values. We smooth the raw density using nonparametric kernel density estimation with a normal kernel of bandwidth {sigma}. We calibrate the dependence of {sigma} on n by Monte Carlo experiments performed on samples drawn from a theoretical density, in which the integrated square error is minimized. We scale this calibration to the ranges of real RV samples using the Normal Reference Rule. The resolution and amplitude accuracy of the estimated density improve with n. For typical RV and ML samples, we expect the fractional noise at the PDF peak to be approximately 80 n{sup -log2}. For illustrations, we apply the new method to 67 RV values given a similar treatment by Jorissen et al. in 2001, and to the 308 RV values listed at exoplanets.org on 2010 October 20. In addition to analyzing observational results, our methods can be used to develop measurement requirements-particularly on the minimum sample size n-for future programs, such as the microlensing survey of Earth-like exoplanets recommended by the Astro 2010 committee.

79 ASTRONOMY AND ASTROPHYSICS↗

Least-squares finite element methods for quantum chromodynamics

A significant amount of the computational time in large Monte Carlo simulations of lattice quantum chromodynamics (QCD) is spent inverting the discrete Dirac operator. Unfortunately, traditional covariant finite difference discretizations of the Dirac operator present serious challenges for standard iterative methods. For interesting physical parameters, the discretized operator is large and ill-conditioned, and has random coefficients. More recently, adaptive algebraic multigrid (AMG) methods have been shown to be effective preconditioners for Wilson's discretization of the Dirac equation. This paper presents an alternate discretization of the Dirac operator based on least-squares finite elements. The discretization is systematically developed and physical properties of the resulting matrix system are discussed. Finally, numerical experiments are presented that demonstrate the effectiveness of adaptive smoothed aggregation ({alpha}SA ) multigrid as a preconditioner for the discrete field equations resulting from applying the proposed least-squares FE formulation to a simplified test problem, the 2d Schwinger model of quantum electrodynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous segmentation and reconstruction: A level set method approach for limited view computed tomography

Purpose: An iterative tomographic reconstruction algorithm that simultaneously segments and reconstructs the reconstruction domain is proposed and applied to tomographic reconstructions from a sparse number of projection images. Methods: The proposed algorithm uses a two-phase level set method segmentation in conjunction with an iterative tomographic reconstruction to achieve simultaneous segmentation and reconstruction. The simultaneous segmentation and reconstruction is achieved by alternating between level set function evolutions and per-region intensity value updates. To deal with the limited number of projections, a priori information about the reconstruction is enforced via penalized likelihood function. Specifically, smooth function within each region (piecewise smooth function) and bounded function intensity values for each region are assumed. Such a priori information is formulated into a quadratic objective function with linear bound constraints. The level set function evolutions are achieved by artificially time evolving the level set function in the negative gradient direction; the intensity value updates are achieved by using the gradient projection conjugate gradient algorithm. Results: The proposed simultaneous segmentation and reconstruction results were compared to ''conventional'' iterative reconstruction (with no segmentation), iterative reconstruction followed by segmentation, and filtered backprojection. Improvements of 6%-13% in the normalized root mean square error were observed when the proposed algorithm was applied to simulated projections of a numerical phantom and to real fan-beam projections of the Catphan phantom, both of which did not satisfy the a priori assumptions. Conclusions: The proposed simultaneous segmentation and reconstruction resulted in improved reconstruction image quality. The algorithm correctly segments the reconstruction space into regions, preserves sharp edges between different regions, and smoothes the noise within each region. The proposed algorithm framework has the flexibility to be adapted to different a priori constraints while maintaining the benefits achieved by the simultaneous segmentation and reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inhibition of cell proliferation by a selective inhibitor of the Ca{sup 2+}-activated Cl{sup -} channel, Ano1

Highlights: Black-Right-Pointing-Pointer T16A{sub inh}-A01 blocked Ano1 currents in HEK cells expressing Ano1. Black-Right-Pointing-Pointer T16A{sub inh}-A01 reduced proliferation in ICC primary cultures and CFPAC-1 cell line. Black-Right-Pointing-Pointer T16A{sub inh}-A01 reduced proliferation of ICC in intact smooth muscle strips. -- Abstract: Background: Ion channels play important roles in regulation of cellular proliferation. Ano1 (TMEM16A) is a Ca{sup 2+}-activated Cl{sup -} channel expressed in several tumors and cell types. In the muscle layers of the gastrointestinal tract Ano1 is selectively expressed in interstitial cells of Cajal (ICC) and appears to be required for normal gastrointestinal slow wave electrical activity. However, Ano1 is expressed in all classes of ICC, including those that do not generate slow waves suggesting that Ano1 may have other functions. Indeed, a role for Ano1 in regulating proliferation of tumors and ICC has been recently suggested. Recently, a high-throughput screen identified a small molecule, T16A{sub inh}-A01 as a specific inhibitor of Ano1. Aim: To investigate the effect of the T16A{sub inh}-A01 inhibitor on proliferation in ICC and in the Ano1-expressing human pancreatic cancer cell line CFPAC-1. Methods: Inhibition of Ano1 was demonstrated by whole cell voltage clamp recordings of currents in cells transfected with full-length human Ano1. The effect of T16A{sub inh}-A01 on ICC proliferation was examined in situ in organotypic cultures of intact mouse small intestinal smooth muscle strips and in primary cell cultures prepared from these tissues. ICC were identified by Kit immunoreactivity. Proliferating ICC and CFPAC-1 cells were identified by immunoreactivity for the nuclear antigen Ki67 or EdU incorporation, respectively. Results: T16A{sub inh}-A01 inhibited Ca{sup 2+}-activated Cl{sup -} currents by 60% at 10 {mu}M in a voltage-independent fashion. Proliferation of ICC was significantly reduced in primary cultures from BALB/c mice following treatment with T16A{sub inh}-A01. Proliferation of the CFPAC-1 human cell-line was also reduced by T16A{sub inh}-A01. In organotypic cultures of smooth muscle strips from mouse jejunum, the proliferation of ICC was reduced but the total number of proliferating cells/confocal stack was not affected, suggesting that the inhibitory effect was specific for ICC. Conclusions: The selective Ano1 inhibitor T16A{sub inh}-A01 inhibited Ca{sup 2+}-activated Cl{sup -} currents, reduced the number of proliferating ICC in culture and inhibited proliferation in the pancreatic cancer cell line CFPAC-1. These data support the notion that chloride channels in general and Ano1 in particular are involved in the regulation of proliferation.

60 APPLIED LIFE SCIENCES↗

Real-Time Tumor Tracking in the Lung Using an Electromagnetic Tracking System

Purpose: To describe the first use of the commercially available Calypso 4D Localization System in the lung. Methods and Materials: Under an institutional review board-approved protocol and an investigational device exemption from the US Food and Drug Administration, the Calypso system was used with nonclinical methods to acquire real-time 4-dimensional lung tumor tracks for 7 lung cancer patients. The aims of the study were to investigate (1) the potential for bronchoscopic implantation; (2) the stability of smooth-surface beacon transponders (transponders) after implantation; and (3) the ability to acquire tracking information within the lung. Electromagnetic tracking was not used for any clinical decision making and could only be performed before any radiation delivery in a research setting. All motion tracks for each patient were reviewed, and values of the average displacement, amplitude of motion, period, and associated correlation to a sinusoidal model (R{sup 2}) were tabulated for all 42 tracks. Results: For all 7 patients at least 1 transponder was successfully implanted. To assist in securing the transponder at the tumor site, it was necessary to implant a secondary fiducial for most transponders owing to the transponder's smooth surface. For 3 patients, insertion into the lung proved difficult, with only 1 transponder remaining fixed during implantation. One patient developed a pneumothorax after implantation of the secondary fiducial. Once implanted, 13 of 14 transponders remained stable within the lung and were successfully tracked with the tracking system. Conclusions: Our initial experience with electromagnetic guidance within the lung demonstrates that transponder implantation and tracking is achievable though not clinically available. This research investigation proved that lung tumor motion exhibits large variations from fraction to fraction within a single patient and that improvements to both transponder and tracking system are still necessary to create a clinical daily-use system to assist with actual lung radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ice Phase Classification Made Easy with Score-Based Denoising

Accurate identification of ice phases is essential for understanding various physicochemical phenomena. However, such classification for structures simulated with molecular dynamics is complicated by the complex symmetries of ice polymorphs and thermal fluctuations. For this purpose, both traditional order parameters and data-driven machine learning approaches have been employed, but they often rely on expert intuition, specific geometric information, or large training data sets. In this work, we present an unsupervised phase classification framework that combines a score-based denoiser model with a subsequent model-free classification method to accurately identify ice phases. Further, the denoiser model is trained on perturbed synthetic data of ideal reference structures, eliminating the need for large data sets and labeling efforts. The classification step utilizes the smooth overlap of atomic position (SOAP) descriptors as the atomic fingerprint, ensuring Euclidean symmetries and transferability to various structural systems. Our approach achieves a remarkable 100% accuracy in distinguishing ice phases of test trajectories using only seven ideal reference structures of ice phases as model inputs. This demonstrates the generalizability of the score-based denoiser model in facilitating phase identification for complex molecular systems. The proposed classification strategy can be broadly applied to investigate structural evolution and phase identification for a wide range of materials, offering new insights into the fundamental understanding of water and other complex systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗