Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface Engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient thin film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better turbulence models. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity and also the mean temperature and normalized root mean square (rms) temperatures in a single injector cooling flow arrangement. In addition to flowfield measurements, thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of radial and axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures and Mach numbers, across a 30.48cm long plate equipped with a single injector cooling hole. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 15 axial stations were collected in the same flows. The velocity and temperature data were then compared against Wind-US CFD code predictions for the same flow conditions. The results of this and planned follow-on studies will support NASA's development and assessment of turbulence models for heated flows.

Turbulence Modeling↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity as well as the mean temperature and root mean square (rms) temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to M0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report and are available from the NASA STI office. The final portion of the data will be published in a future report, Part II, along with CFD predictions of the complex cooling film flow.

IR camera Measurments↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part 1

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity as well as the mean temperature and root mean square (rms) temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to M0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report and are available from the NASA STI office. The final portion of the data will be published in a future report, Part II, along with CFD predictions of the complex cooling film flow.

Raman Scattering↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data was obtained to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean and root mean square (rms) velocities as well as the mean and rms temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to Mach 0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both streamwise 2-component PIV (on the plate centerline) and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report. The rest of the data will be published in a future report, Part II, along with planned CFD predictions of the complex cooling film flow. The entire data set of Raman temperature data, PIV velocity data and IR camera data covering the Set Points 23 and 49 in the test matrix in Table 1 is available in an accompanying DVD (available online from www.sti.nasa.gov) for those interested in further analysis.

Nozzle↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hotor combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean and root mean square (rms) velocities as well as the mean and rms temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR =2.7) and Mach numbers (up to Mach 0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both streamwise 2-component PIV (along the plate centerline) and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part 1 report. The rest of the data will be published in a future report, Part 2, along with planned CFD predictions of the complex cooling film flow.The entire data set of Raman temperature data, PIV velocity data and IR camera data covering the Set Points 23 and 49 in the test matrix in Table 1 is available in an accompanying DVD (available online from www.sti.nasa.gov) for those interested in further analysis.

Mark P Wernet↗

Advances in Plume-Surface Interaction Simulation Capability Under Lunar Landing Conditions

Plume-Surface Interaction (PSI) between lander engine plumes and native regolith soil presents primary hazards in obscuration and contamination by particle clouds, high-energy ejecta streams, and landing area cratering damage. The MSFC Fluid Dynamics Branch has assembled a portfolio of simulation tools to develop a predictive PSI capability for NASA customers such as the Human Lander System (HLS) and Commercial Lunar Payload Services (CLPS). These tools are matured via funding by NASA’s STMD Game Changing Development Program and the NASA SBIR/STTR Program.

Peter A Liever↗

TO252: Parabolic Flight Demonstration of Fluid Dispensing Tube Performance Limits for Drop Delivery

Ring Shear Drop (RSD) ISS flight hardware failed to pin sample fluid drops between two rings, likely due to dynamic instability inherent to the dispensing tube (D-Tube) design. The first parabolic flight tested 5 D-tube tip designs with two bounding surface tension fluids, enabling an engineering design decision. D-tube Tip Cage Design was selected based on the November 2020 parabolic flight test data. Flight Operations Program (FOP) approved a reflight proposal to include 2 parabolic flight days during the April/May 2021 campaign with following objectives: • Validate ISS hardware flight design with actual flight fluids (test as you fly), demonstrating the ability to deliver 1” fluid drops in near-microgravity conditions. • Demonstrate pinning of 1” flight fluid drops: a secondary pinning ring is planned to be installed in the parabolic flight hardware to meet this objective. Fluid flow rates will also be varied as needed and as possible. • Provide data to validate computational models used to guide ISS operational deployment decisions and demonstrate the viability of the redesigned hardware to accommodate a range of future flight investigations. This presentation introduces highlights and lessons learned during this recent flight campaign for discussion in the Flight Opportunities Program Panel, “Leveraging Suborbital Flight Tests to Advance Science and Technology."

Sridhar Gorti↗

Temperature Sensing to Above 1500 °C Using Y 2 SiO 5 :Er Phosphor Thermometry

A transition from metallic to ceramic turbine components that can operate at higher turbine engine temperatures will push component surface temperatures from below 1200 °C into a 1300 to 1500 °C temperature range that is much more challenging for phosphor thermometry measurements. To address this challenge, Y 2 SiO 5 :Er was selected for its high temperature sensing performance by both luminescence lifetime and luminescence intensity ratio (LIR) methods as well as its thermochemical compatibility with the current generation of rare earth silicate environmental barrier coatings (EBCs) that are required to protect SiC/SiC ceramic composite components. Lifetime measurements that monitor the Er3+ 4S3/2→4I15/2 emission decay at 542 nm exhibited a slow decrease in decay time with temperature up to 1300° C, above which the decay decreased steeply to provide good temperature sensitivity in the 1300 to 1500 °C range (Fig. 1). LIR images were obtained where each pixel represented the ratio I488/I561 (I488 and I561 are the detected 488 nm 4F7/2→4I15/2 and the 561 nm 4S3/2→4I15/2 emission band intensities, respectively). Good temperature sensitivity (Fig. 2) and signal-to-background ratios were observed to above 1500 °C. Contrary to conventional guidance on selecting phosphors for high temperature sensing, the detected emission band intensities and decay times exhibited remarkably slow decreases with temperature up into the 1300 to 1500 °C range despite high phonon energies (>900 cm-1) that allow the energy gap between the 4S3/2 emitting reservoir level and the 4F9/2 level below it to be bridged by as few as three phonons. The benefits of utilizing a thermographic phosphor at very high temperatures that exhibits strong nonradiative multiphonon relaxation even at room temperature is explained by a competition between spontaneous and stimulated multiphonon emission, and the more temperature-sensitive decay time above 1300 °C is explained by a transition from high to low effective phonon energies.

temperature measurement↗

NASA's Center Innovation Fund (CIF) Internal Research and Development (IRAD) Handling Qualities Study on the Mikrolar Motion Platform Test Report

In order to support the National Aeronautics and Space Administration’s (NASA) Extravehicular Activity and Surface Mobility Program (EHP), system engineers, designers, and researchers embarked on a yearlong challenge to develop a new lunar rover-based motion table simulator to study handling qualities of lunar rovers in the lunar South Pole region, support development research for any lunar rover vendor, and provide a lunar training capability for future lunar/planetary astronauts. In 1989, the United Kingdom’s Royal Air Force Institute of Aviation Medicine (RAF-IAM) stated that motion platforms are the only simulation devices capable of fully stimulating the body motion sensors. They confirmed that motion platforms can impart accelerations to the whole body and therefore exercise the automatic motion feedback-loop that operators are used to. With both visual and motion cues handling the vehicle becomes more realistic. Strachan (2019) con-firms motion cueing from a well set-up motion platform has been found to be important especially in conditions such as night or reduced visibility where motion cues may be more relied upon

Motion Table↗

On the State of the Art of Metal Interconnects for SOFC Application

One of the recent developments for Solid Oxide Fuel Cells (SOFC) is oxide component materials capable of operating at lower temperatures such as 700-800C. This lower temperature range has provided for the consideration of metallic interconnects which have several advantages over ceramic interconnects: low cost, ease in manufacturing, and high conductivity. Most metals and alloys will oxidize under both the anode and cathode conditions within an SOFC, thus a chief requirement is that the base metal oxide scale must be electrically conductive since this constitutes the majority of the electrical resistance in a metallic interconnect. Common high temperature alloys form scales that contain chrome, silicon and aluminum oxides among others. Under SOFC operating conditions chrome oxide is a semi-conductor while silicon and aluminum oxides are insulators. In this talk we will review the evolution in candidate alloys and surface modifications which constitute an engineered solution for SOFC interconnect applications.

30 DIRECT ENERGY CONVERSION↗

US Army Corps of Engineers Section 404: permitting of valley fills - red flag or red tape?

Since 2001 the US Army Corps of Engineers has been permitting most surface coal mines as Individual Permits rather than Nationwide Permits under the Section 404 program. This was shown in a survey by Skelly & Loy of permits published by Huntingdon Crops District and the state of Kentucky. Nationwide Permit 21 (NWP21) authorises the filling of waters of the United States associated with surface coal mining and reclamation operations already authorised or currently being processed as part of the integrated permit processing procedure. NWP21 has received much opposition and two noticeable court cases involving it, in West Virginia and Kentucy, are briefly reported. The article first appeared in Skelly & Loy's newsletter, Portal to the mining industry, Vol II, Issue 1. 4 photos.

01 COAL, LIGNITE, AND PEAT↗

Considerations for improving the biosphere assessment methodology and the associated conceptual and mathematical models for application to LLW/ILW radioactive wastes in Spain - 15194

We give consideration to future needs in assessment studies relating to the disposal of very low level radioactive waste (VLLW), low level radioactive waste (LLW) and intermediate level radioactive waste (ILW) in Spain. As these wastes are primarily disposed at El Cabril, particular attention is given to the characteristics of that site. The focus is on post-closure performance assessment studies and specifically on the biosphere aspect of those studies. In particular, it gives consideration to the assessment methodology that should be used, taking into account the recommendations made in the international BIOMASS and BIOCLIM programs, as well as more recent developments. It then goes on to consider the conceptual models of the biosphere that should be developed and comments on how these should be transformed into mathematical models. The issues arising in conceptual and mathematical model development are illustrated by reference to El Cabril, but several of these issues would also be applicable to other engineered facilities excavated from the surface in a variety of geographical and geological contexts. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Topological surface superconductivity in FeSe 0.45 Te 0.55

The engineering of Majorana zero modes in topological superconductors, a paradigm for the realization of topological quantum computing and topology-based devices, has been hampered by the absence of materials with sufficiently large superconducting gaps. Recent experiments, however, have provided enthralling evidence for the existence of topological surface superconductivity in the iron-based superconductor FeSe 0.45 Te 0.55 possessing a full s> ± -wave gap of a few meV. Here, we propose a mechanism for the emergence of topological superconductivity on the surface of FeSe 0.45 Te 0.55 by demonstrating that the interplay between the s ± -wave symmetry of the superconducting gap, surface magnetism, and a Rashba spin–orbit interaction gives rise to robust topological superconducting phases. Moreover, the proposed mechanism explains a series of experimentally observed hallmarks of topological superconductivity, such as the emergence of Majorana zero modes in the center of vortex cores and at the end of line defects, as well as of chiral Majorana edge modes along domain walls. We also propose that the spatial distribution of supercurrents near a domain wall is a characteristic signature measurable via a scanning superconducting quantum interference device that can distinguish between chiral Majorana edge modes and trivial in-gap states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of Steam Delivery of the Working Fluid on Tool Wear

The delivery of working fluid to the cutting zone in a current of steam supplied by a steam generator is considered. This method improves the machining of metals, reduces tool wear, and improves the surface quality of the product.

42 ENGINEERING↗

Numerical Optimization of Spray-Guided Spark Assistance for Cold Idle Operation in a Heavy-Duty Gasoline Compression Ignition Engine

This article describes the results of a response surface model (RSM)-based numerical optimization campaign for spray-guided spark assistance at cold operations in a heavy-duty gasoline compression ignition (GCI) engine. On the basis of an earlier work on spark-assisted GCI cold combustion, a space-filling design of experiments (DoE) method was first undertaken to investigate a multitude of hardware design variables and engine operating parameters. The main design variables included the number of injector nozzles, fuel split quantities and injection timings, and spark timing. The objective variables were engine combustion efficiency (ŋ c ), maximum pressure rise rate (MPRR), and engine-out nitrogen oxide (NO x ) emissions. A total of 150 design candidates were automatically generated using the Sobol sequence method provided by the commercial software package, CAESES. Then, closed-cycle computational fluid dynamic (CFD) spark-assisted GCI simulations under cold idling operations were performed. The outcomes from the CFD-DoE design campaign were utilized to construct high-fidelity RSMs that allowed for further design optimization of the spark plug- and fuel injector-related design variables, along with fuel injection strategy parameters. A merit function with respect to objective variables was formulated with an appropriate weight assignment on each objective variable. Finally, the best design candidate was identified from the RSM-based optimization process and further validated in the CFD analysis. The best design candidate showed the potential to significantly improve combustion efficiency (ŋ c > 90%) over the baseline at cold idle while satisfying MPRR and NOx emissions constraints (MPRR < 5 bar/CAD and NO x < 4.5 g/kWh).

33 ADVANCED PROPULSION SYSTEMS↗

Applying Infrared Thermography as a Method for Online Monitoring of Turbine Blade Coolant Flow

As gas turbine engine manufacturers strive to implement condition-based operation and maintenance, there is a need for blade monitoring strategies capable of early fault detection and root-cause determination. Given the importance of blade cooling flows to turbine blade health and longevity, there is a distinct lack of methodologies for coolant flowrate monitoring. The present study addresses this identified opportunity by applying an infrared thermography system on an engine-representative research turbine to generate data-driven models for prediction of blade coolant flowrate. Thermal images were used as inputs to a linear regression and regularization algorithm to relate blade surface temperature distribution with blade coolant flowrate. Additionally, this study investigates how coolant flowrate prediction accuracy is influenced by the number and breadth of diagnostic measurements. Here, the results of this study indicate that a source of high-fidelity training data can be used to predict blade coolant flowrate within about six percent error. Furthermore, identification of prioritized sensor placement supports application of this technique across multiple sensor technologies capable of measuring blade surface temperature in operating gas turbine engines, including spatially resolved and point-based measurement techniques.

42 ENGINEERING↗

Performance Characteristics of a Normal-shock Side Inlet Located Downstream of a Canard Control Surface at Mach Numbers of 1.5 and 1.8/

The performance characteristics of a downward canted normal-shock side (scoop) inlet located downstream of a triangular control surface are presented for free-stream Mach numbers of 1.5 and 1.8 in terms of total pressure recovery and mass flow ratio for various boundary-layer removal systems,angles of attack, control surface deflections and adverse yaw. An engine operating condition for a hypothetical turbojet engine is established, and the match point characteristics of the engine-inlet configuration are summarized. 520::It is shown that the diffuser performance increases with increased boundary-layer removal and decreases because of the presence of the wake from the forward control surface. At the higher angles of attack the wake passes over the inlet and does not affect the inlet performance. Adverse yaw reduces the total pressure recovery values below those for the unawed case. Magnitudes of the total pressure recovery were below the theoretical normal-shock recovery for the respective test Mach numbers.

INLETS, SIDE - DUCTED BODIES↗

Full-scale upper-surface-blown flap noise

A highly noise-suppressed TF 34 engine was used to investigate the noise of several powered lift configurations involving upper-surface-blown (USB) flaps. The configuration variables were nozzle type (i.e. slot and circular with deflector), flap chord-length, and flap angle. The results of velocity surveys at both the nozzle exit and the flap trailing edge are used for correlation of the noise data. Configurations using a long flap design were 4 dB quieter than a short flap typical of current trends in USB flap design. The lower noise for the long flap is attributed primarily to the greater velocity decay of the jet at the flap trailing edge. The full-scale data revealed substantially more quadrupole noise in the region near the deflected jet than observed in previous sub-scale tests.

Heidelberg, L. J.↗