Search NASA⌕ Search

SEARCH · Search NASA

Results for “System reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Space Vehicle Reliability Modeling in DIORAMA

When modeling system performance of space based detection systems it is important to consider spacecraft reliability. As space vehicles age the components become prone to failure for a variety of reasons such as radiation damage. Additionally, some vehicles may lose the ability to maneuver once they exhaust fuel supplies. Typically failure is divided into two categories: engineering mistakes and technology surprise. This document will report on a method of simulating space vehicle reliability in the DIORAMA framework.

33 ADVANCED PROPULSION SYSTEMS↗

Reliable voltage scaled links for compressed data

Systems, apparatuses, and methods for reliably transmitting data over voltage scaled links are disclosed. A computing system includes at least first and second devices connected via a link. In one implementation, if a data block can be compressed to less than or equal to half the original size of the data block, then the data block is compressed and sent on the link in a single clock cycle rather than two clock cycles. If the data block cannot be compressed to half the original size, but if the data block can be compressed enough to include error correction code (ECC) bits without exceeding the original size, then ECC bits are added to the compressed block which is sent on the link at a reduced voltage. The ECC bits help to correct for any errors that are generated as a result of operating the link at the reduced voltage.

42 ENGINEERING↗

Final Report Start-Up and Commissioning Tests on the DuraMelter 1200 HLW Pilot Melter System Using AZ-101 HLW Simulants

This document provides the final report on data and results obtained from commissioning tests performed on the one-third scale DuraMelter{trademark} 1200 (DM 1200) HLW Pilot Melter system that has been installed at VSL with an integrated prototypical off-gas treatment system. That system has replaced the DM1000 system that was used for HLW throughput testing during Part BI [1]. Both melters have similar melt surface areas (1.2 m{sup 2}) but the DM1200 is prototypical of the present RPP-WTP HLW melter design whereas the DM1000 was not. These tests were performed under a corresponding RPP-WTP Test Specification and associated Test Plan. This report is a followup to the previously issued Preliminary Data Summary Report. The DM1200 system will be used for testing and confirmation of basic design, operability, flow sheet, and process control assumptions as well as for support of waste form qualification and permitting. This will include data on processing rates, off-gas treatment system performance, recycle stream compositions, as well as process operability and reliability. Consequently, this system is a key component of the overall HLW vitrification development strategy. The results presented in this report are from the initial series of short-duration tests that were conducted to support the start-up and commissioning of this system prior to conducting the main body of development tests that have been planned for this system. These tests were directed primarily at system 'debugging,' operator training, and procedure refinement. The AZ-101 waste simulant and glass composition that was used for previous testing was selected for these tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fault Survivability of Lightweight Operating Systems for exascale

Concern is growing in the High-Performance Computing community regarding the reliability of proposed exascale systems. Current research has shown that the expected reliability of these machines will greatly reduce their scalability. In constrast to current fault tolerance methods whose reliability focus is only the application, this project investigates the benefits integrating reliability mechcanisms in the operating system and runtime, as well as the appli- cation. More specifically, this project has three broad contributions in the field: First, using failure logs from current leadership-class high-performance computing systems, we outline the failures common on these large-scale systems. Second, we describe a novel memory pro- tection mechcanism capable of protecting common observed failures that uses the similarity inherrant in many OS and applications state, thereby reducing overheads. Finally, using an analogy with OS jitter, we develop a highly effecient simulator capable predicting the performance of resilience methods at the scales expected for future extreme-scale systems.

97 MATHEMATICS AND COMPUTING↗

Real-Time Automated Hazard Detection Framework for Health Information Technology Systems

An increase in the reliability of Health Information Technology (HIT) will facilitate institutional trust and credibility of the systems. Here, we present an end-to-end framework for improving the reliability and performance of HIT systems. Specifically, we describe the system model, present some of the methods that drive the model, and discuss an initial implementation of two of the proposed methods using data from the Veterans Affairs HIT and Corporate Data Warehouse systems. The contributions of this work, thus, include (1) the design of a system model for monitoring and detecting hazards in HIT systems, (2) a data-driven approach for analysing the health care data warehouse, (3) analytical methods for characterising and analysing failures in HIT systems, and (4) a tool architecture for generating and reporting hazards in HIT systems. Our goal is to work towards an automated system that will help identify opportunities for improvements in HIT systems.

97 MATHEMATICS AND COMPUTING↗

Performance prediction of refrigerant-DMF solutions in a single-stage solar-powered absorption refrigeration system at low generating temperatures

A theoretical analysis of the coefficient of performance was undertaken to examine the efficiency characteristics of R22 + DMF, R134a + DMF, R32 + DMF as working fluids, respectively, for a single-stage and intermittent absorption refrigerator which allows the use of heat pipe evacuated tubular collectors. The modeling and simulation of the performance considers both solar collector system and the absorption cooling system. The typical meteorological year file containing the weather parameters for Hangzhou is used to simulate the system. The results show that the system is in phase with the weather. In order to increase the reliability of the system, a hot water storage tank is essential. The optimum ratio of storage tank per solar collector area for Hangzhou's climate for a 1.0 kW system is 0.035-0.043L. Considering the relative low pressure and the high coefficient of performance, R134a + DMF mixture presents interesting properties for its application in solar absorption cycles at moderate condensing and absorbing temperatures when the evaporating temperatures in the range from 278 K to 288 K which are highly useful for food preservation and for air-conditioning in rural areas. (author)

14 SOLAR ENERGY↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids: Preprint

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Network reliability assessment

The present disclosure pertains to systems and methods for assessing reliability of communication links in a software defined network (SDN). In one embodiment, a system may include an SDN architecture subsystem configured to generate SDN architecture information and a bandwidth subsystem configured to generate bandwidth information. A latency subsystem may receive the bandwidth information from the bandwidth subsystem and may be configured to generate latency information using the bandwidth information. A failover subsystem may receive the SDN architecture information, the bandwidth information, and the latency information and generate a failover assessment and a failover route for the communication link. A reliability assessment subsystem may receive the SDN architecture information, the bandwidth information, and the latency information, and the failover assessment and generate a reliability assessment. A traffic routing subsystem may receive the reliability assessment and route data traffic to the failover route based on the reliability assessment.

Smith, Rhett↗

The Binary INformation from Open Clusters Using SEDs (BINOCS) Project: Reliable Photometric Mass Determinations of Binary Star Systems in Clusters

We introduce a new binary detection technique, Binary INformation from Open Clusters using SEDs (binocs), which we show is able to determine reliable stellar multiplicity and masses over a much larger mass range than current approaches. This new technique determines accurate component masses of binary and single systems of the open clusters’ main sequence by comparing observed magnitudes from multiple photometric filters to synthetic star spectral energy distributions (SEDs), allowing us to systematically probe the binary population for low-mass stars in clusters for eight well-studied open clusters. We provide new deep, infrared photometric catalogs (1.2–8.0 μm) for the key open clusters NGC 1960 (M36), NGC 2099 (M37), NGC 2420, and NGC 2682 (M67), using observations from NOAO/NEWFIRM and Spitzer/IRAC. Using these deep multiwavelength catalogs, the binocs method is applied to these clusters to determine accurate component masses for unresolved cluster binaries. We explore binary fractions as a function of cluster age, Galactic location, and metallicity.

47 OTHER INSTRUMENTATION↗

Design of isolated renewable hybrid power systems

Isolated electrical power generating units can be used as an economically viable alternative to electrify remote villages where grid extension is not feasible. One of the options for building isolated power systems is by hybridizing renewable power sources like wind, solar, micro-hydro, etc. along with appropriate energy storage. A method to optimally size and to evaluate the cost of energy produced by a renewable hybrid system is proposed in this paper. The proposed method, which is based on the design space approach, can be used to determine the conditions for which hybridization of the system is cost effective. The simple and novel methodology, proposed in this paper, is based on the principles of process integration. It finds the minimum battery capacity when the availability and ratings of various renewable resources as well as load demand are known. The battery sizing methodology is used to determine the sizing curve and thereby the feasible design space for the entire system. Chance constrained programming approach is used to account for the stochastic nature of the renewable energy resources and to arrive at the design space. The optimal system configuration in the entire design space is selected based on the lowest cost of energy, subject to a specified reliability criterion. The effects of variation of the specified system reliability and the coefficient of correlation between renewable sources on the design space, as well as the optimum configuration are also studied in this paper. The proposed method is demonstrated by designing an isolated power system for an Indian village utilizing wind-solar photovoltaic-battery system. (author)

14 SOLAR ENERGY↗

Fuel Cell Backup Power System for Grid-Service and Micro-Grid in Telecommunication Applications

This paper presents the feasibility and economics of using fuel cell backup power systems in telecommunication cell towers to provide grid services (e.g., ancillary services, demand response). The fuel cells are able to provide power for the cell tower during emergency conditions. This study evaluates the strategic integration of clean, efficient, and reliable fuel cell systems with the grid for improved economic benefits. The backup systems have potential as enhanced capability through information exchanges with the power grid to add value as grid services that depend on location and time. The economic analysis has been focused on the potential revenue for distributed telecommunications fuel cell backup units to provide value-added power supply. This paper shows case studies on current fuel cell backup power locations and regional grid service programs. The grid service benefits and system configurations for different operation modes provide opportunities for expanding backup fuel cell applications responsive to grid needs. The objective of this work primarily focuses on how fuel cells can become a significant part of the telecom backup power to reduce system costs, environmental impact, and dependence on fossil fuels, while ensuring continuity of indispensable service for mobile users. The study identifies the approaches on the fuel cell application through nano/microgrids for an extensive network of fuel cells as distributed energy resources. The possibilities of various application scenarios extend the fuel cell technologies and microgrid for reliable power supply.

30 DIRECT ENERGY CONVERSION↗

Investigation of the Use of Dynamic Probabilistic Risk Assessment Methodologies for Identifying Digital I&C System Common Cause Failures

Digital Instrumentation and Control (I&C) systems have a key role in nuclear power plants in the upgrade of aging analog systems. Digital systems improve plant safety and reliability through features such as increased hardware reliability and stability and improved failure detection capability. There is no consensus on which of the current probabilistic risk assessment methods are most suitable for use in the reliability analysis of digital I&C systems. While the traditional event-tree/fault-tree (ET/FT) approach is still used for their reliability modeling, there are concerns regarding this approach in properly accounting for dynamic interactions among system components since potentially significant dependencies among failure events may not be identified and/or their likelihood may not be properly quantified. Dynamic methodologies are expected to provide a much more accurate representation of probabilistic evolution of the I&C systems in time due to their capability to more properly account for complex interactions than the static approach. The applicability of dynamic PRA methodologies for digital I&C system is investigated using the criteria presented in the NUREG/CR-6901, and the comparisons made in NUREG/CR-6901 are updated in light of the latest studies. The Dynamic Event Tree (DET) approach has been identified as one of the top dynamic methods when evaluated against the requirements for the reliability modeling of digital I&C systems. The DET method is a strong candidate for integration into existing PRA studies, as it bears many similarities to the traditional ET approach. In this study, the DET approach has been applied to the Plant Protection System of the APR1400 design, and the results are compared to results from its available traditional ET/FT analysis. Possible approaches to evaluate and quantify the effects of common cause failures on system safety using dynamic methods are also examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Automated Tool for Supporting FMEAs of Digital Systems

Although designs of digital systems can be very different from each other, they typically use many of the same types of generic digital components. Determining the impacts of the failure modes of these generic components on a digital system can be used to support development of a reliability model of the system. A novel approach was proposed for such a purpose by decomposing the system into a level of the generic digital components and propagating failure modes to the system level, which generally is time-consuming and difficult to implement. To overcome the associated issues of implementing the proposed FMEA approach, an automated tool for a digital feedwater control system (DFWCS) has been developed in this study. The automated FMEA tool is in nature a simulation platform developed by using or recreating the original source code of the different module software interfaced by input and output variables that represent physical signals exchanged between modules, the system, and the controlled process. For any given failure mode, its impacts on associated signals are determined first and the variables that correspond to these signals are modified accordingly by the simulation. Criteria are also developed, as part of the simulation platform, to determine whether the system has lost its automatic control function, which is defined as a system failure in this study. The conceptual development of the automated FMEA support tool can be generalized and applied to support FMEAs for reliability assessment of complex digital systems.

42 ENGINEERING↗

Modeling the Control Systems of Gas-Turbines to Ensure Their Reliable Parallel Operation in the UPS of Russia

Consideration is given to different approaches to modeling the control systems of gas turbines as a component of CCPP and GTPP to ensure their reliable parallel operation in the UPS of Russia. The disadvantages of the approaches to the modeling of combined-cycle units in studying long-term electromechanical transients accompanied by power imbalance are pointed out. Examples are presented to support the use of more detailed models of gas turbines in electromechanical transient calculations. It is shown that the modern speed control systems of gas turbines in combination with relatively low equivalent inertia have a considerable effect on electromechanical transients, including those caused by disturbances not related to power imbalance.

42 ENGINEERING↗

SNL evaluation of Gigabit Passive Optical Networks (GPON).

Gigabit Passive Optical Networks (GPON) is a networking technology which offers the potential to provide significant cost savings to Sandia National Laboratories in the area of network operations. However, a large scale GPON deployment requires a significant investment in equipment and infrastructure. Before a large scale GPON system was acquired and built, a small GPON system manufactured by Motorola was acquired and tested. The testing performed was to determine the suitability of GPON for use at SNL. This report documents that testing. This report presents test results of GPON system consisting of Motorola and Juniper equipment. The GPON system was tested in areas of data throughput, video conferencing, VOIP, security, and operations and management. The GPON system performed well in almost all areas. GPON will not meet the needs of the low percentage of users requiring a true 1-10 Gbps network connection. GPON will also most likely not meet the need of some servers requiring dedicated throughput of 1-10 Gbps. Because of that, there will be some legacy network connections that must remain. If these legacy network connections can not be reduced to a bare minimum and possibly consolidated to a few locations, any cost savings gained by switching to GPON will be negated by maintaining two networks. A contract has been recently awarded for new GPON equipment with larger buffers. This equipment should improve performance and further reduce the need for legacy network connections. Because GPON has fewer components than a typical hierarchical network, it should be easier to manage. For the system tested, the management was performed by using the AXSVison client. Access to the client must be tightly controlled, because if client/server communications are compromised, security will be an issue. As with any network, the reliability of individual components will determine overall system reliability. There were no failures with the routers, OLT, or Sun Workstation Management platform. There were however four ONTs that failed. Because of the small sample size of 64, and the fact that some of the ONTs were used units, no conclusions can be made. However, ONT reliability is an area of concern. Access to the fiber plant that GPON requires must be tightly controlled and all changes documented. The undocumented changes that were performed in the GPON test lab demonstrated the need for tight control and documentation. In summary, GPON should be able to meet the needs of most network users at Sandia National Laboratories. Because it supports voice, video, and data, it positions Sandia National Laboratories to deploy these services to the desktop. For the majority of corporate network users at Sandia National Laboratories GPON should be a suitable replacement for the legacy network.

99 GENERAL AND MISCELLANEOUS↗

Control and automation of the Pegasus multi-point Thomson scattering system

A new control system for the Pegasus Thomson scattering diagnostic has recently been deployed to automate the laser operation, data collection process, and interface with the system-wide Pegasus control code. Automation has been extended to areas outside of data collection, such as manipulation of beamline cameras and remotely controlled turning mirror actuators to enable intra-shot beam alignment. Additionally, the system has been upgraded with a set of fast (∼1 ms) mechanical shutters to mitigate contamination from background light. Modification and automation of the Thomson system have improved both data quality and diagnostic reliability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advance Local Mobility Through Energy Efficient Mobility Systems Technologies

Everyone deserves reliable, affordable, and safe transportation to connect people to jobs, healthcare, education, and recreation. Our transportation systems are interconnected, multimodal networks working together to move people and goods. These systems are dynamic and are being reshaped by factors such as population trends, new technologies, shifting labor models, economic forces, and changing climate. Energy efficient mobility systems (EEMS) technologies can help transportation planners ensure changes in our transportation systems are equitable and sustainable by improving energy efficiency, travel time, and affordability, as well as overall access to mobility. Transportation planners and decision makers can use the following EEMS tools and strategies to advance local mobility.

ADVANCED PROPULSION SYSTEMS↗

Implementation and Operation of Power Flow Control Solutions for Transmission Systems

Power-flow controls (PFCs) technologies provide a suite of alternatives to more-efficiently direct the flow of power on the grid, improving flexibility and enabling the grid to be more responsive and resilient. PFCs can be used in many cases to mitigate overloads and consequently defer the installation of grid-expansion projects. They can also be suitable options in situations where new transmission lines cannot be built because of environmental constraints, land use, or other types of restrictions. Other uses include mitigation of loop or unintended flows, forcing of contractual or scheduled flows, reduction of congestion, and mitigation solutions during large maintenance or construction projects. While many studies have demonstrated the potential economic benefits of PFC for different types of applications, the implementation implications of using multiple PFCs for system operation and reliability have not been analyzed in detail. The lack of information and practical experience on these aspects hinders adoption of this technology. One use case would be that multiple PFCs are required to coordinate congestion management. In such cases, multiple PFCs are deployed in a meshed power system to control power flows across a wide area. The challenges are associated with PFC interaction—namely, the self and mutual power-flow sensitivity of each PFC, which must be accounted for in the calculation of the respective operating setpoints. This report analyzes implementation and operation that must be considered in evaluating transmission solutions using PFCs. The report first analyzes attributes with which PFC-based solutions should comply, based on the objective and characteristics of each particular use case. It then describes different approaches for coordinated control of multiple PFC devices for different applications, including options to avoid adverse interactions and reduce risks due to inappropriate coordination. Control and operation are illustrated through case studies performed on both generic and actual power system models. This report provides insights for transmission planners and operation engineers about the implementation of PFC-based transmission solutions; consequently, it will help them make informed decisions about the adoption of the technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗