Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Evaluation of Safety Standards for Fuel System and Fuel Container Integrity of Alternative Fuel Vehicles

There are two Federal Motor Vehicle Safety Standards (FMVSS) in place that specify requirements for integrity of the fuel system and fuel container on compressed natural gas (CNG) fuel vehicles. These are FMVSS Nos. 303, “Fuel system integrity of compressed natural gas vehicles,” and FMVSS No. 304, “CNG fuel container integrity.” At this time, no FMVSS are defined for the fuel system and fuel container integrity of propane and liquefied natural gas (LNG) vehicles or fuel system integrity requirements for heavy-duty CNG vehicles on the road. However, there are voluntary industry design standards and best practices, as well as regulations defined in other countries. FMVSS No. 303 specifies requirements for the integrity of the CNG fuel system of light-duty vehicles and school buses, and FMVSS No. 304 specifies requirements for fuel container integrity on all CNG vehicles. FMVSS No. 304 applies to containers used for vehicle propulsion, whereas containers used to transport CNG and transportation of CNG containers are regulated by the DOT Pipeline and Hazardous Materials Safety Administration. FMVSS Nos. 303 and 304 are performance-based standards to consistently test and validate equipment and are not design restrictive. Despite the increasing number of natural gas and propane medium- and heavy-duty vehicles on the road, there are no FMVSS fuel system integrity requirements beyond light-duty and school buses for CNG vehicles and no FMVSS fuel system integrity requirements for propane vehicles. NHTSA is researching fuel system safety for medium- and heavy-duty natural gas and propane vehicles to update FMVSS Nos. 303 and 304. NHTSA is also researching current best practices and standards for high pressure fuel tanks in motor vehicles as they may apply to FMVSS No. 304.

30 DIRECT ENERGY CONVERSION↗

Design, testing and emplacement of sand-bentonite for the construction of a gas-permeable seal test (gast)

The main aim of a gas-permeable seal is to increase the gas transport capacity of the backfilled underground structures without compromising the radionuclide retention capacity of the engineered barrier system or the host rock. Such a seal, proposed by NAGRA as part of the 'Engineered Gas Transport System' in a L/ILW repository, considers specially designed backfill and sealing materials such as sand/bentonite (S/B) mixtures with a bentonite content of 20- 30%. NAGRA's RD and D plan foresees demonstrating the construction and performance of repository seals and improving the understanding and the database for reliably predicting water and gas transport through these systems. The fluid flow and gas transport properties of these backfills have been determined at the laboratory scale and through modelling the maximum gas pressures in the near field of a repository system and the gas flow rates have been evaluated. Within this context, the Gas-permeable Seal Test (GAST) was constructed at Grimsel Test Site (GTS) to validate the effective functioning of gas-permeable seals at realistic scale. The intrinsic permeability of such seals should be in the order of 10-18 m2. Because the construction of S/B seals is not common practice for construction companies, a stepwise approach was followed to evaluate different construction and quality assurance methods. As a first step, an investigation campaign with simple tests in the laboratory and in the field followed by 1:1 scale pre-tests at GTS was performed. Through this gradual increase of the degree of complexity, practical experience was gained and confidence in the methods and procedures to be used was built, which allowed reliably producing and working with S/B mixtures at a realistic scale. During the whole pre-testing phase, a quality assurance (QA) programme for S/B mixtures was developed and different methods were assessed. They helped to evaluate and choose appropriate emplacement techniques and methodologies to achieve the target S/B dry density of 1.70 g/cm{sup 3}, which results in the desired intrinsic permeability throughout the experiment. The final QA methodology was targeted at engineering measures to decide if the work can proceed, and at producing high resolution material properties database for future water and gas transport modelling activities. The different applied QA techniques included standard core cutter tests, the application of neutron-gamma (Troxler) probes and two mass balance methods (2D and 3D). The methods, looking at different representative scales, have provided only slightly different results and showed that the average density of the emplaced S/B plug was between 1.65 and 1.73 g/cm{sup 3}. Spatial variability of dry densities was observed at decimeter scale. Overall, the pre-testing and QA programme performed for the GAST project demonstrated how the given design criteria and requirements can be met by appropriately planning and designing the material emplacement. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Waiting for precise measurements of K{sup +}{yields}{pi}{sup +}{nu}{nu} and K{sub L}{yields}{pi}{sup 0}{nu}{nu}

In view of future plans for accurate measurements of the theoretically clean branching ratios Br(K{sup +}{yields}{pi}{sup +}{nu}{nu}) and Br(K{sub L}{yields}{pi}{sup 0}{nu}{nu}), which should occur in the next decade, the relevant formulas for quantities of interest are collected and their theoretical and parametric uncertainties are analyzed. In addition to the angle {beta} in the unitarity triangle (UT), the angle {gamma} can also be determined from these decays with respectable precision and in this context the importance of the recent NNLO QCD calculation on the charm contribution to K{sup +}{yields}{pi}{sup +}{nu}{nu} and of the improved estimate on the long-distance contribution by means of chiral perturbation theory are presented. In addition to known expressions, several new ones that should allow transparent tests of the standard model (SM) and of its extensions are presented. While the review is centered around the SM, models with minimal flavor violation and scenarios with new complex phases in decay amplitudes and meson mixing are also discussed. A review of existing results within specific extensions of the SM, in particular the littlest Higgs model with T-parity, Z{sup '} models, the MSSM, and a model with one universal extra dimension are given. A new ''golden'' relation between B and K systems is derived that involves ({beta},{gamma}) and Br(K{sub L}{yields}{pi}{sup 0}{nu}{nu}), and the virtues of (R{sub t},{beta}), (R{sub b},{gamma}), ({beta},{gamma}), and ({eta},{gamma}) strategies for the UT in the context of K{yields}{pi}{nu}{nu} decays with the goal of testing the SM and its extensions are investigated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of vertical betatron oscillations using the straw tracking detectors for the E989 muon g-2 experiment at Fermilab.

The measurement of the anomalous magnetic moment of electrons and muons has been an important test of the Standard Model (SM) of particle physics over many decades. This is because it can be measured experimentally and calculated theoretically to a high precision. In particular the anomalous magnetic moment of the muon, a µ , is an ideal candidate for the search of new physics due to the combination of the muons large mass and relatively long lifetime. The current world’s most precise value of aµ was measured by the E821 experiment at the Brookhaven National laboratory (BNL). This achieved a precision of 540 ppb (463 ppb stat., 283 ppb syst.) and measured a ~ 3.5 σ deviation from the SM value [1]. This motivated a new experiment: the E989 muon g–2 experiment at the Fermi National Accelerator Laboratory (Fermilab) to confirm or reject this discrepancy. This experiment aims to gather a data sample 21 times larger than the BNL experiment and improve the determination of the systematic uncertainties by a factor of three and thereby achieve a fourfold increase in precision to 140 ppb [2]. If the aµ value were to remain unchanged, this improvement in precision would establish evidence for Beyond SM (BSM) physics with a significance of more than 7 standard deviations. The Fermilab experiment has the same methodology as the BNL experiment and reuses the experiment’s storage ring magnet. New, improved experimental apparatus has been introduced to reduce the systematic uncertainty on the a µ measurement. One such improvement is the addition of two straw tracking stations. These measure the trajectory of the positrons emitted from the (positive) muon decays which allows a detailed study of the spatial and temporal motion of the beam and critical crosschecks of the calorimeter data. This thesis describes in detail the design, construction and testing of the tracking detectors which were built at the University of Liverpool. A detailed study of the vertical motion of the beam is also presented. This study provides an important correction that must be applied to the data before a µ can be determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-precision measurement of the W boson mass with the CMS experiment

In the standard model of particle physics, the masses of the W and Z bosons, the carriers of the weak interaction, are uniquely related. A precise determination of their masses is important because quantum loops of heavy, undiscovered particles could modify this relationship. Although the Z mass is known to the remarkable precision of 22 parts per million (2.0 MeV), the W mass is known much less precisely. A global fit to measured electroweak observables predicts the W mass with 6 MeV uncertainty [1$-$3]. Reaching a comparable experimental precision would be a sensitive and fundamental test of the standard model, made even more urgent by a recent challenge to the global fit prediction by a measurement from the CDF Collaboration at the Fermilab Tevatron collider [4]. Here we report the measurement of the W mass by the CMS Collaboration at the CERN LHC, based on a large data sample of $W \to \mu \nu$ events collected in 2016 at the proton-proton collision energy of 13 TeV. The measurement exploits a high-granularity maximum likelihood fit to the kinematic properties of muons produced in W decays. By combining an accurate determination of experimental effects with marked in situ constraints of theoretical inputs, we reach a precise measurement of the W mass, of 80 360.2 $\pm$ 9.9 MeV, in agreement with the standard model prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent Standard Model measurements

A selection of recent Standard Model measurements from ATLAS, CMS, D0 and HERA Collaborations is presented. The topics include studies of QCD with jets, photons and vector bosons as well as the latest measurements of the strong coupling constant. The status and prospects of precision measurements of the $W$-boson mass, the mixing angle of the electroweak interaction and the top-quark mass are also presented followed by recent results in the top-quark sector, on multibosons produced inclusively and on the study of the vector boson fusion and scattering. These measurements and studies provide stringent tests of the Standard Model. Deviations with respect to the Standard Model predictions are valuable probes of potential New Physics effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantifying Uncertainty in Tortuosity Estimates for Porous Electrodes

Measuring tortuosity in porous electrodes is important for understanding rate capability and optimizing design. Here, we describe an approach to determine electrode tortuosities and quantify the associated uncertainties by fitting a P2D model to discharge profiles from a standard rate capability test. A dimensionless current is identified as a design-of-experiment parameter that can be used to identify experiments that return confident estimates of tortuosity, even when other model parameters are not known with certainty. This approach is applied to analysis of L i x V 3 O 8 (LVO) electrodes and L i x N i 0.33 M n 0.33 C o 0.33 O 2 (NMC) electrodes. The details of the assumptions made in these measurements and their impact on the reported uncertainties are discussed. We also perform an uncertainty analysis on the standard method for quantifying tortuosity in the literature: electrochemical impedance spectroscopy collected under blocking electrolyte conditions. We find that confident estimates can be obtained using this approach even when uncertainties in equivalent circuit model parameters are considered.

25 ENERGY STORAGE↗

The National Dissemination of International Measurements

The paper presents the most significant actions which a primary Radionuclide Metrology Laboratory must accomplish, in order to disseminate the international equivalence to the entire national traceability chain: absolute standardization methods and demonstration of international equivalence, construction and calibration of a consistent set of secondary standardization equipment, preparation of radioactive standards. Delivery of radioactive standards to the end users and carrying out metrological services. Organization of national proficiency tests with the users. International validation of secondary standards by proficiency tests and establishment of a Quality System Assurance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The mimetic finite difference method for the Landau–Lifshitz equation

The Landau–Lifshitz equation describes the dynamics of the magnetization inside ferromagnetic materials. This equation is highly nonlinear and has a non-convex constraint (the magnitude of the magnetization is constant) which poses interesting challenges in developing numerical methods. We develop and analyze explicit and implicit mimetic finite difference schemes for this equation. These schemes work on general polytopal meshes which provide enormous flexibility to model magnetic devices with various shapes. A projection on the unit sphere is used to preserve the magnitude of the magnetization. We also provide a proof that shows the exchange energy is decreasing in certain conditions. The developed schemes are tested on general meshes that include distorted and randomized meshes. As a result, the numerical experiments include a test proposed by the National Institute of Standard and Technology and a test showing formation of domain wall structures in a thin film.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fuel-Coolant Interaction Results for High Energy In-Pile LWR Fuels Experiments

Fuel-coolant interaction (FCI) has long been a subject of interest in severe-accident reactor safety applications. Significant chemical interaction also frequently results at the high temperature associated with these events in a water environment. Historical rapid, high energy transient irradiation test results are reviewed for experiments performed in transient experimental reactors in Idaho. Though such events are not credible for any deployed nuclear reactor technology, the pressure waves produced by FCI on surrounding containment structures are of importance to advanced light water reactor designs and for transient experiment design considerations. A brief introduction to steam explosion and related studies is provided in the context of these experiments. Extensive reactivity initiated accident testing programs were carried out in the Transient REActor Test (TREAT) facility, the Special Power Excursion Reactor Test (SPERT) facility, and the Power Burst Facility (PBF) from the 1960’s through the late 1970’s. A variety of fuel forms including waterlogged rods were tested in capsules containing water coolant at standard temperature pressure. A few tests were performed at high pressure and temperature in the water loop of PBF. In many of these experiments, energy deposition was high enough to greatly exceed melting temperatures of the fuel, resulting in some fraction of the fuel being dispersed into the coolant. A purpose of many of these tests was to determine the nuclear-to-mechanical energy conversion ratio as well as the extent of metal-water reaction. Relevant data collected from these tests included transient energy deposition, pressure response of the coolant, water column velocity, total hydrogen generation, and resulting particle size distributions and particle characterization. In this paper, the mechanical configuration of each experiment facility is reviewed and discussed relative to the measured responses. The empirical results for source pressure and extent of metal-water reaction are presented in the context of the experimental conditions. The results of these experiments provide a unique understanding for behavior of fuel under severe accident conditions in a reactor environment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Research Opportunities in Reliability of Photovoltaic Modules (Presentation)

The motivation for an increased scope and a more proactive effort in reliability research of photovoltaic modules and systems includes reducing the levelized cost of energy and gaining better confidence in the energy and financial payback for photovoltaic systems. This increased reliability and confidence will lead to greater penetration of photovoltaics in the energy portfolio and greateremployment in photovoltaics and related industries. Present research needs include the fundamental degradation mechanisms of polymers, connectors and other module components, mapping of failure mechanisms observed in the field to those in accelerated lifetime tests, determining the acceleration factors, and improving standards for modules such that tests can appropriately be assigned to evaluatetheir long term durability. Specific mechanisms discussed are corrosion in module components, metastability in thin-film active layers, delamination and loss of elastic properties in module polymeric materials, and inverter failure. Presently, there is hiring of reliability scientists and engineers at many levels of the value chain for photovoltaics.

14 SOLAR ENERGY↗

Standard Model Prediction for Direct C P Violation in K → π π Decay

In this paper, we report the first lattice QCD calculation of the complex kaon decay amplitude A 0 with physical kinematics, using a 32 3 x 64 lattice volume and a single lattice spacing a, with 1/a = 1.3784(68) GeV. We find Re(A 0 ) = 4.66(1.00)(1.26) x 10 -7 GeV and Im(A 0 ) = -1.90(1.23)(1.08) x 10 -11 GeV, where the first error is statistical and the second systematic. The first value is in approximate agreement with the experimental result: Re(A 0 ) = 3.3201(18) x 10 -7 GeV, while the second can be used to compute the direct CP-violating ratio Re(ϵ'/ϵ) = 1.38(5.15)(4.59) x 10 -4 , which is 2.1σ below the experimental value 16.6(2.3) x 10 -4 . Finally, the real part of A 0 is CP conserving and serves as a test of our method while the result for Re(ϵ'/ϵ) provides a new test of the standard model theory of CP violation, one which can be made more accurate with increasing computer capability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the measurement of austenite in supermartensitic stainless steel by X-ray diffraction

Sections of a 13Cr supermartensitic stainless steel were investigated to determine the optimum sample preparation for measurement of the austenite content by X-ray diffraction. The surface of several samples was mechanically ground or polished using media of grit sizes in the range 1–120 μm. The strained surface layer was afterwards removed stepwise by electropolishing, and the austenite content measured at each step. It was found that any level of mechanical grinding or polishing results in a reduction of the measured austenite fraction relative to the true bulk value, and that coarser grinding media impart greater damage and greater reduction in the measured austenite content. The results thus highlight the importance of the electropolishing step in preparation of such samples, but suggest that the American Society for Testing and Materials standard E975-03 substantially overestimates the amount of material which needs to be removed to recover the true “bulk” content. - Highlights: • Quantitative Rietveld analysis of austenite/martensite ratio in supermartensitic stainless steels • Critical evaluation of sample preparation for residual austenite measurements by X-ray diffraction • Highlighting of the importance of electropolishing as a final preparation step.

36 MATERIALS SCIENCE↗

Performance of first prototype multi-cell low-surface-field shape cavity

The idea of cavity shaping for higher ultimate acceleration gradients has been proposed for some time, Low Loss/Ichiro and Re-entrant being examples, both seeking a lower Hpk/Eacc at the expense of a higher Epk/Eacc. While experimental verification in single-cell cavities of those shapes was very successful including the record gradient of 59 MV/m, pushing multi-cell cavities of those shapes to higher gradients was prevented by field emission. The Low-Surface-Field (LSF) shape seeks not only a lower Hpk/Eacc but also a lower Epk/Eacc, therefore it has the advantage of raising ultimate gradient at reduced field emission. The first multi-cell LSF shape prototype cavity was built using the standard forming and welding techniques. RF tests have been carried out, following standard ILC TDR baseline surface processing and treatment recipe. Three out of five cells achieved Hpk values corresponding to Eacc 50 MV/m. The current limit is the field emission in end cells. Instrumented testing following end-cell wiping and HPR with larger nozzles is in progress. We will present detailed experimental results and preparation procedures.

Geng, R.-L.↗

Validation of the DESI-DR1 3x2-pt analysis: scale cut and shear ratio tests

Combined survey analyses of galaxy clustering and weak gravitational lensing (3x2-pt studies) will allow new and accurate tests of the standard cosmological model. However, careful validation is necessary to ensure that these cosmological constraints are not biased by uncertainties associated with the modelling of astrophysical or systematic effects. In this study we validate the combined 3x2-pt analysis of the Dark Energy Spectroscopic Instrument Data Release 1 (DESI-DR1) spectroscopic galaxy clustering and overlapping weak lensing datasets from the Kilo-Degree Survey (KiDS), the Dark Energy Survey (DES), and the Hyper-Suprime-Cam Survey (HSC). By propagating the modelling uncertainties associated with the non-linear matter power spectrum, non-linear galaxy bias and baryon feedback, we design scale cuts to ensure that measurements of the matter density and the amplitude of the matter power spectrum are biased by less than 30% of the statistical error. We also test the internal consistency of the data and weak lensing systematics by performing new measurements of the lensing shear ratio. We demonstrate that the DESI-DR1 shear ratios can be successfully fit by the same model used to describe cosmic shear correlations, and analyse the additional information that can be extracted about the source redshift distributions and intrinsic alignment parameters. This study serves as crucial preparation for the upcoming cosmological parameter analysis of these datasets.

Emas, N. [Swinburne U., Ctr. Astrophys. Supercompu↗

PV Module and System Reliability Research

While photovoltaic (PV) technologies have experienced widespread success and adoption, continued growth of these technologies - especially new PV technologies - requires ongoing improvements to their reliability and the testing procedures, data, and standards that underpin them. To better understand and address failure mechanisms of PV modules and systems, NREL conducts testing, models failures, analyzes performance data, helps to develop standards, and convenes expert stakeholders. This work is focused both on improving the performance of industry-dominant PV technologies and rapidly de-risking new PV technologies so they can be proven reliable without decades of field testing.

14 SOLAR ENERGY↗

Flavor-dependent radiative corrections in coherent elastic neutrino-nucleus scattering

We calculate coherent elastic neutrino-nucleus scattering cross sections on spin-0 nuclei (e.g. 40 Ar and 28 Si) at energies below 100 MeV within the Standard Model and account for all effects of permille size. We provide a complete error budget including uncertainties at nuclear, nucleon, hadronic, and quark levels separately as well as perturbative error. Our calculation starts from the four-fermion effective field theory to explicitly separate heavy-particle mediated corrections (which are absorbed by Wilson coefficients) from light-particle contributions. Electrons and muons running in loops introduce a non- trivial dependence on the momentum transfer due to their relatively light masses. These same loops, and those mediated by tau leptons, break the flavor universality because of mass-dependent electromagnetic radiative corrections. Nuclear physics uncertainties significantly cancel in flavor asymmetries resulting in subpercent relative errors. We find that for low neutrino energies, the cross section can be predicted with a relative precision that is competitive with neutrino-electron scattering. We highlight potentially useful applications of such a precise cross section prediction ranging from precision tests of the Standard Model, to searches for new physics and to the monitoring of nuclear reactors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Test Report for the Qualification Testing of the ORNL-SFC-W-1 Special Form Capsule

Three prototypes the ORNL-SFC-W-1 special form capsules (SFCs) of the same design were evaluated to determine if the requirements of Title 49, Code of Federal Regulations (CFR), Part 173.469, Tests for Special Form Class 7 (Radioactive) Materials, were met. The results of the special form tests are documented in this test report. This report describes the special form testing activities performed on the three ORNL-SFC-W-1 capsules. The test units were designated as TU-1, TU-2 and TU-3. TU-1 was subjected to leak testing, impact testing and percussion testing. TU-1 was leak tested using the leak rate test specified in 49 CFR 173.469(a)(4)(i). The impact test was conducted according to the requirements in 49 CFR 173.469 (b)(1). The percussion test that was carried out on TU-1 was conducted in accordance with 49 CFR 173.469 (b)(2). Both TU-2 and TU-3 were subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469(b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests as specified in American National Standards Institute (ANSI) N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in American Society for Testing and Measurement (ASTM) E 493. The determined standardized leak rates obtained from the test and the calculations for all the test units met the requirements for special form certification. The testing was performed under the direction of the Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP).

42 ENGINEERING↗