Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Direct spectral measurements of midinfrared radiation from a laser wakefield accelerator

The formation of plasma waves during laser wakefield acceleration (LWFA) produces time-dependent frequency shifts in the driving laser pulse, extending its spectral content to the infrared. We present direct spectral measurements of multi-mJ infrared pulses from an LWFA. Experimental beam profile measurements and three-dimensional particle-in-cell simulations suggest high focusability of these pulses. Further, particle-in-cell simulations demonstrate that the measurement of side-scattered infrared radiation may serve as a diagnostic of plasma waves and the efficiency of spectral broadening during LWFA.

43 PARTICLE ACCELERATORS↗

Z{sub eff} profile measurement system with an optimized Czerny-Turner visible spectrometer in large helical device

Z{sub eff} measurement system using a visible spectrometer has been newly designed and constructed instead of an old interference filter system to eliminate line emissions from the signal and to measure the Z{sub eff} value in low-density plasmas. The system consists of the Czerny-Turner-type spectrometer with a charge-coupled device camera and 44 optical fibers vertical array. The spectrometer is equipped with an additional toroidal mirror for further reduction in the astigmatism in addition to a flat and two spherical mirrors and three gratings (110, 120, and 1200 grooves/mm) with 30 cm focal length. The images from 44 optical fibers can be detected without astigmatism in a wavelength range of 200-900 nm. Combination of the optical fiber (core diameter: 100 {mu}m) with the lens (focal length: 30 mm) provides spatial resolution of 30 mm at the plasma center. Results clearly indicate a very good focus image of the fiber and suggest the absence of the cross-talk between adjacent fiber images. Absolute intensity calibration has been done using a standard tungsten lamp to analyze the Z{sub eff} value. The bremsstrahlung profile and resultant Z{sub eff} profile have been obtained after Abel inversion of the signals observed in large helical device plasmas with elliptical poloidal cross section.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast scanning probe for the NSTX spherical tokamak

We describe a fast reciprocating Langmuir probe and drive system, which has four main new features: (1) use of high-temperature, vacuum, circuit boards instead of cables to reduce weight and increase to 21 the number of possible connections, (2) rotatable and removable shaft, (3) 10 tip construction with designed hardware bandwidth up to 10 MHz, and (4) a detachable and modular tip assembly for easy maintenance. The probe is mounted in a fast pneumatic drive capable of speeds {approx}7 m/s and {approx}20g's acceleration in order to reach the scrape-off layer (SOL) and pedestal regions and remain inserted long enough to obtain good statistics while minimizing the heat deposition to the tips and head in a power density environment of 1-10 MW/m{sup 2}. The National Spherical Torus Experiment SOL features electron temperature, T{sub e}{approx}10-30 eV, and electron density, n{sub e}{approx}0.1-5x10{sup 12} cm{sup -3} while the pedestal features n{sub e}{approx}0.5-1.5x10{sup 13} cm{sup -3} and T{sub e}{approx}30-150 eV. The probe described here has ten tips which obtain a wide spectrum of plasma parameters: electron temperature profile T{sub e}(r), electron density profile n{sub e}(r) and Mach number profile M(r), floating potential V{sub f}(r), poloidal and radial electric field profiles E{sub {theta}}(r) and E{sub {rho}}(r), saturation current profile I{sub sat}(r), and their fluctuations up to 3 MHz. We describe the probe and show representative radial profiles of various parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of aperture and beam lifetime using movable beam scrapers in Indus-2 electron storage ring

In this paper, the measurements of vertical and horizontal aperture which are available for stable beam motion in Indus-2 at beam energy 2.5 GeV using movable beam scrapers are presented. These beam scrapers are installed in one of the long straight sections in the ring. With the movement of beam scrapers towards the beam centre, the beam lifetime is measured. The beam lifetime data obtained from the movement of vertical and horizontal beam scrapers are analyzed. The contribution of beam loss due to beam-gas scattering (vacuum lifetime) and electron-electron scattering within a beam bunch (Touschek lifetime) is separated from the measured beam lifetime at different positions of the beam scrapers. Vertical and horizontal beam sizes at scrapers location are estimated from the scraper movement towards the beam centre in quantum lifetime limit and their values closely agree with measured value obtained using X-ray diagnostic beamline.

43 PARTICLE ACCELERATORS↗

Ambient-temperature liquid jet targets for high-repetition-rate HED discovery science

High-power lasers can generate energetic particle beams and astrophysically relevant pressure and temperature states in the high-energy-density (HED) regime. Recently-commissioned high-repetition-rate (HRR) laser drivers are capable of producing these conditions at rates exceeding 1 Hz. However, experimental output from these systems is often limited by the difficulty of designing targets that match these repetition rates. To overcome this challenge, we have developed tungsten microfluidic nozzles, which produce a continuously replenishing jet that operates at flow speeds of approximately 10 m/s and can sustain shot frequencies up to 1 kHz. The ambient-temperature planar liquid jets produced by these nozzles can have thicknesses ranging from hundreds of nanometers to tens of micrometers. In this work, we illustrate the operational principle of the microfluidic nozzle and describe its implementation in a vacuum environment. Further, we provide evidence of successful laser-driven ion acceleration using this target and discuss the prospect of optimizing the ion acceleration performance through an in situ jet thickness scan. Future applications for the jet throughout HED science include shock compression and studies of strongly heated nonequilibrium plasmas. When fielded in concert with HRR-compatible laser, diagnostic, and active feedback technology, this target will facilitate advanced automated studies in HRR HED science, including machine learning-based optimization and high-dimensional statistical analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics for PSR Upgrade

This report discusses the diagnostics upgrade plan for the PSR. The PSR diagnostics under discussion include beam position and phase monitor (BPPM), wirescanners, wall current monitors, bunch shape monitors, laser notchers, and diamond array detectors. Existing diagnostics at the PSR include beam position monitors (BPM), a wirescanner, and a wall current monitor. All existing diagnostics need modernization, as part of the PSR upgrade plan. Meanwhile, we will introduce minor changes to improve the existing setups, which will enhance the performance and the longevity of the diagnostics equipment and components in the upgraded PSR operation. On the other hand, new, advanced, and available diagnostic technologies at a high technology readiness level (TRL) can also be considered for implementation for the PSR upgrade. In this note, we go through all types of diagnostics, introducing their basic principle, operating status, and plans for the PSR upgrade.

43 PARTICLE ACCELERATORS↗

Start-to-End Optics Validation of FFA-Based Energy Upgrade to CEBAF

This project will thoroughly validate the optics for a proof-of-principal, proposed FFA-based energy upgrade for CEBAF. This upgrade consists of CBETA-like FFA arcs in place of the highest-energy recirculating arcs in the machine, allowing for several more passes through the linacs. This should enable a highest beam energy of 20-24 GeV. This LDRD project will include Start-to-End (S2E) optics and beam dynamics simulations, beam loss and power deposition, and indicate requirements for updates to diagnostics.

43 PARTICLE ACCELERATORS↗

Final Technical Report, DOE Grant DE-FG02-98ER54496, Physics of High-Energy-Density X Pinch Plasmas

Abstract for the Final Technical Report, DOE Grant DE-FG02-98ER54496 An X-pinch plasma is produced by driving a high current (100-500 kiloamperes) through two or more fine wires that cross and touch at a point, forming an X in the case of two wires. The wires explode because of the high current, and then the resulting plasma is imploded radially inward by the magnetic field from the current. When the imploding material briefly stagnates at very small radius and high density, an intense burst of x-rays is produced and the plasma disassembles as rapidly as it imploded. When this project began, we could confidently state that at its minimum radius, X pinch plasmas made from such materials as titanium and molybdenum might be as hot as 10,000,000 K and had densities almost as high as the solid wire density, but their X-ray pulse durations were below one billionth of a second. We could also say that the X pinch was useful for point-projection imaging of rapidly changing objects, such as exploding wires, with high resolution, indicative of a very small X-ray source spot size. We can now confidently say that X-pinch plasma temperatures at the moment of the X-ray burst are 10-25 million K in titanium, molybdenum and several other wire X-pinches based upon the spectrum of emitted X-rays in the radiation burst. By the same means, as well as from the penetration of X-rays through the dense plasma, we know that ion densities are close to or higher than one-tenth of the density of the original (solid) wire material in molybdenum and a few other X-pinch plasmas. Furthermore, using the diffraction of X-rays radiated by the X-pinch when it reaches minimum radius, we have determined that the x-ray source size is about 1 thousandth of a millimeter for such wire materials as molybdenum and niobium, while it is 2-10 times larger for tungsten, titanium and aluminum wires. Finally, using a very high speed X-ray imaging “streak camera,” we have determined that X pinch X-ray pulses can be as short as 30 trillionths of a second. Additional experiments have demonstrated that a spherical shell of plasma expands away from the cross point region after the x-ray burst. It reaches millimeter scale in a few billionths of a second, leaving a small (less than 0.1 millimeter) gap in the middle that enables energetic electrons to be accelerated to 10 or a few 10’s of kilovolts of energy. In addition to gaining an understanding of the physics of the X pinch plasmas, we have had to develop several new X-ray diagnostic devices in order to obtain and verify the above results. On the non-technical side, 4 students have completed Ph.D.s working under the auspices of this project, including one woman, and another woman has begun her Ph.D. research under this project. In addition, several undergraduate students have worked with us on the X-pinch experiments, including one who is now a graduate student in plasma physics at Princeton University.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Symposium (International) on Combustion, 20th, University of Michigan, Ann Arbor, MI, August 12-17, 1984, Proceedings

The present conference on combustion phenomena considers topics in automotive engine combustion, turbulent reacting flows, the modeling of practical combustion systems, reaction kinetics, combustion-generated particulates, combustion diagnostics, coal combustion process characteristics, fire-related phenomena, explosion/detonation phenomena, spray combustion, ignition/extinction, laminar flames, pollutant formation processes, practical combustor devices, and rocket propellant combustion. Attention is given to the contributions of combustion science to piston engine design, modeling and measurement techniques for turbulent combustion, the specific effects of energy, collisions, and transport processes in combustion chemistry kinetics, the formation of large molecules, particulates and ions in premixed hydrocarbon flames, the application of laser diagnostics to combustion systems, spark ignition energies for dust-air mixtures, the controlling mechanisms of flow-assisted flame spread, the ignition and combustion of coal-water slurries, spontaneous ignition of methane, turbulent and accelerating dust flames, and the temperature sensitivity of double base propellants.

Source record↗

Proteus two-dimensional Navier-Stokes computer code, version 2.0. Volume 2: User's guide

A computer code called Proteus 2D was developed to solve the two-dimensional planar or axisymmetric, Reynolds-averaged, unsteady compressible Navier-Stokes equations in strong conservation law form. The objective in this effort was to develop a code for aerospace propulsion applications that is easy to use and easy to modify. Code readability, modularity, and documentation were emphasized. The governing equations are solved in generalized nonorthogonal body-fitted coordinates, by marching in time using a fully-coupled ADI solution procedure. The boundary conditions are treated implicitly. All terms, including the diffusion terms, are linearized using second-order Taylor series expansions. Turbulence is modeled using either an algebraic or two-equation eddy viscosity model. The thin-layer or Euler equations may also be solved. The energy equation may be eliminated by the assumption of constant total enthalpy. Explicit and implicit artificial viscosity may be used. Several time step options are available for convergence acceleration. The documentation is divided into three volumes. This is the User's Guide, and describes the program's features, the input and output, the procedure for setting up initial conditions, the computer resource requirements, the diagnostic messages that may be generated, the job control language used to run the program, and several test cases.

Towne, Charles E.↗

TPSAS-NF1676L-21180-DND

Ablative materials are used as the Thermal Protection System (TPS) for space vehicles that enter a planetary atmosphere. During the entry phase, the vehicle experiences high rates of aerodynamic heating. These ablative materials, acting as a heat shield, protect the vehicle from the harsh environment and ensure a safe entry. Ablative materials reduce the incoming heat flux through various phenomena such as near-surface oxidation, pyrolysis chemical reaction, vaporization, and other erosive processes, collectively known as ablation. Spallation is one such ablative process, in which solid particles are ejected from the material into the flow field. The many conditions leading to spallation, however, are not well understood and cannot be described accurately by simple phenomenological models. However, the spallation phenomenon might impact the aerodynamic heating rates of re-entry vehicles using ablative heat shields. For example, the solid particles ejected from the surface can modify the near surface chemical processes and flow field. To investigate spallation effects, a code was developed to compute the dynamics of spalled particles. The code uses a finite-rate chemistry model to study the chemical interactions of the particles with the flow field. The spallation code is dynamically coupled to a CFD solver that models the time accurate hypersonic flow field around an ablative sample. An experimental investigation was also performed at the NASA Langley HYMETS facility. HYMETS is a 400 kW arcjet that can simulate hypersonic flight and Earth or Martian entry conditions. Using high speed cameras, an IR camera, NIR and UV-VIS spectrometers, and other diagnostic instruments, test data on various graphite, LI-900, FiberForm, and PICA test samples were obtained, using target heat flux conditions of 100, 200, and 400 W/cm 2 . From the test campaign, measurements of particle velocity, acceleration and trajectory are obtained.

A Martin↗

Optimization of THz Radiation Generation from a Laser Wakefield Accelerator

Ultrashort terahertz pulses with energies in the {mu}J range can be generated with laser wakefield accelerators (LWFA), which are novel, compact accelerators that produce ultrashort electron bunches with energies up to 1 GeV and energy spreads of a few-percent. Laser pulses interacting with a plasma create accelerated electrons which upon exiting the plasma emit terahertz pulses via transition radiation. Because these electron bunches are ultrashort (<50 fs), they can radiate coherently (coherent transition radiation--CTR) in a wide bandwidth ({approx}1-10 THz) yielding high intensity terahertz pulses. In addition to providing a non-invasive bunch-length diagnostic and thus feedback for the LWFA, these high peak power THz pulses are suitable for high field (MV/cm) pump-probe experiments. Here we present energy-based measurements using a Golay cell and an electro-optic technique which were used to characterize these THz pulses.

43 PARTICLE ACCELERATORS↗

Time Resolved Detectors and Measurements for Accelerators and Beamlines at the Australian Synchrotron

Time resolved experiments require precision timing equipment and careful configuration of the machine and the beamline. The Australian Synchrotron has a state of the art timing system that allows flexible, real-time control of the machine and beamline timing parameters to target specific electron bunches. Results from a proof-of-principle measurement with a pulsed laser and a streak camera on the optical diagnostic beamline will be presented. The timing system was also used to fast trigger the PILATUS detector on an x-ray beamline to measure the fill pattern dependent effects of the detector. PILATUS was able to coarsely measure the fill pattern in the storage ring which implies that fill pattern intensity variations need to be corrected for when using the detector in this mode.

43 PARTICLE ACCELERATORS↗

Recent Developments in High-Harmonic Fast Wave Physics in NSTX

Understanding the interaction between ion cyclotron range of frequency (ICRF) fast waves and the fast-ions created by neutral beam injection (NBI) is critical for future devices such as ITER, which rely on a combination ICRF and NBI. Experiments in NSTX which use 30 MHz High-Harmonic Fast-Wave (HHFW) ICRF and NBI heating show a competition between electron heating via Landau damping and transit-time magnetic pumping, and radio-frequency wave acceleration of NBI generated fast ions. Understanding and mitigating some of the power loss mechanisms outside the last closed flux surface (LCFS) has resulted in improved HHFW heating inside the LCFS. Nevertheless a significant fraction of the HHFW power is diverted away from the enclosed plasma. Part of this power is observed locally on the divertor. Experimental observations point toward the radio-frequency (RF) excitation of surface waves, which disperse wave power outside the LCFS, as a leading loss mechanism. Lithium coatings lower the density at the antenna, thereby moving the critical density for perpendicular fast-wave propagation away from the antenna and surrounding material surfaces. Visible and infrared imaging reveal flows of RF power along open field lines into the divertor region. In L-mode -- low average NBI power -- conditions, the fast-ion D-alpha (FIDA) diagnostic measures a near doubling and broadening of the density profile of the upper energetic level of the fast ions concurrent with the presence of HHFW power launched with k// =-8m-1. We are able to heat NBI-induced H-mode plasmas with HHFW. The captured power is expected to be split between absorption by the electrons and absorption by the fast ions, based on TORIC calculation. In the case discussed here the Te increases over the whole profile when ~2MW of HHFW power with antenna k// =13m-1 is applied after the H-mode transition.. But somewhat unexpectedly fast-ion diagnostics do not observe a change between the HHFW heated NBI discharge and the reference NBI only plasma, although an increase in neutron production is measured. __________________________________________________

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics Goals of DWA Experiments at FACET-II

The dielectric wakefield acceleration (DWA) program at FACET produced a multitude of new physics results that range from GeV/m acceleration to the discovery of high field-induced conductivity in THz waves, and beyond, to a demonstration of positron-driven wakes. Here we review the rich program now developing in the DWA experiments at FACET-II. With increases in beam quality, a key feature of this program is extended interaction lengths, near 0.5 m, permitting GeV-class acceleration. Detailed physics studies in this context include beam breakup and its control through the exploitation of DWA structure symmetry. The next step in understanding DWA limits requires the exploration of new materials with low loss tangent, large bandgap, and improved thermal characteristics. Advanced structures with photonic features for mode confinement and exclusion of the field from the dielectric, as well as quasi-optical handling of coherent Cerenkov signals is discussed. Use of DWA for laser-based injection and advanced temporal diagnostics is examined.

43 PARTICLE ACCELERATORS↗

Low dose megavoltage cone beam computed tomography with an unflattened 4 MV beam from a carbon target

Megavoltage cone beam computed tomography (MVCBCT) is routinely used for visualizing anatomical structures and implanted fiducials for patient positioning in radiotherapy. MVCBCT using a 6 MV treatment beam with high atomic number (Z) target and flattening filter in the beamline, as done conventionally, has lower image quality than can be achieved with a MV beam due to heavy filtration of the low-energy bremsstrahlung. The unflattened beam of a low Z target has an abundance of diagnostic energy photons, detected with modern flat panel detectors with much higher efficiency given the same dose to the patient. This principle guided the development of a new megavoltage imaging beamline (IBL) for a commercial radiotherapy linear accelerator. A carbon target was placed in one of the electron primary scattering foil slots on the target-foil slide. A PROM on a function controller board was programed to put the carbon target in place for MVCBCT. A low accelerating potential of 4.2 MV was used for the IBL to restrict leakage of primary electrons through the target such that dose from x rays dominated the signal in the monitor chamber and the patient surface dose. Results from phantom and cadaver images demonstrated that the IBL had much improved image quality over the treatment beam. For similar imaging dose, the IBL improved the contrast-to-noise ratio by as much as a factor of 3 in soft tissue over that of the treatment beam. The IBL increased the spatial resolution by about a factor of 2, allowing the visualization of finer anatomical details. Images of the cadaver contained useful information with doses as low as 1 cGy. The IBL may be installed on certain models of linear accelerators without mechanical modification and results in significant improvement in the image quality with the same dose, or images of the same quality with less than one-third of the dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new gamma-ray diagnostic for energetic ion distributions - The Compton tail on the neutron capture line

This paper presents a new radiation diagnostic for assaying the energy spectrum and the angular distribution of energetic ions incident on thick hydrogen-rich thermal targets. This diagnostic compares the number of emergent photons in the narrow neutron capture line at 2.223 MeV to the number of Compton scattered photons that form a low-energy tail on the line. It is shown that the relative strength of the tail can be used as a measure of the hardness of the incident ion-energy spectrum. Application of this diagnostic to solar flare conditions is the main thrust of the work presented here. It is examined how the strength of the Compton tail varies with flare viewing angle and the angular distribution of the flare-accelerated particles. Application to compact X-ray binary systems is also briefly discussed.

Vestrand, W. Thomas↗

Plasma Reactor Modeling and Validation Experiments

Plasma processing is a key processing stop in integrated circuit manufacturing. Low pressure, high density plum reactors are widely used for etching and deposition. Inductively coupled plasma (ICP) source has become popular recently in many processing applications. In order to accelerate equipment and process design, an understanding of the physics and chemistry, particularly, plasma power coupling, plasma and processing uniformity and mechanism is important. This understanding is facilitated by comprehensive modeling and simulation as well as plasma diagnostics to provide the necessary data for model validation which are addressed in this presentation. We have developed a complete code for simulating an ICP reactor and the model consists of transport of electrons, ions, and neutrals, Poisson's equation, and Maxwell's equation along with gas flow and energy equations. Results will be presented for chlorine and fluorocarbon plasmas and compared with data from Langmuir probe, mass spectrometry and FTIR.

Meyyappan, M.↗