Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Signatures of hot electrons and fluorescence in Mo Kα emission on Z

Recent experiments on the Z accelerator have produced high-energy (17 keV) inner-shell K-alpha emission from molybdenum wire array z-pinches. Extensive absolute power and spectroscopic diagnostics along with collisional-radiative modeling enable detailed investigation into the roles of thermal, hot electron, and fluorescence processes in the production of high-energy x-rays. We show that changing the dimensions of the arrays can impact the proportion of thermal and non-thermal K-shell x-rays.

74 ATOMIC AND MOLECULAR PHYSICS↗

Precision study of ground state capture in the {sup 14}N(p,{gamma}){sup 15}O reaction

The rate of the hydrogen-burning carbon-nitrogen-oxygen (CNO) cycle is controlled by the slowest process, {sup 14}N(p,{gamma}){sup 15}O, which proceeds by capture to the ground and several excited states in {sup 15}O. Previous extrapolations for the ground state contribution disagreed by a factor 2, corresponding to 15% uncertainty in the total astrophysical S factor. At the Laboratory for Underground Nuclear Astrophysics (LUNA) 400 kV accelerator placed deep underground in the Gran Sasso facility in Italy, a new experiment on ground state capture has been carried out at 317.8, 334.4, and 353.3 keV center-of-mass energy. Systematic corrections have been reduced considerably with respect to previous studies by using a Clover detector and by adopting a relative analysis. The previous discrepancy has been resolved, and ground state capture no longer dominates the uncertainty of the total S factor.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Woodpile Structure Fabrication for Photonic Crystal Laser Acceleration

We describe initial steps at fabricating a dielectric photonic bandgap accelerator structure designed to operate at near IR frequencies. Such a structure operating at these frequencies requires extremely small, sub-micron sized features, forcing one to use lithographic means for fabrication. A process based upon lithographic equipment at the Stanford Nanofabrication Facility has been developed and a four layer test structure has been fabricated. Unexpected problems with the final etch step, and corresponding modifications to the process flow addressing these problems, are described. Spectroscopic measurements of the structure have been taken and are compared to simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Carrier-Envelope Phase Effects in Plasma-Based Electron Acceleration with Few-Cycle Laser Pulses

Carrier-envelope phase effects during the interaction of relativistically intense few-cycle laser pulses with a plasma are studied in the 'bubble' regime when an electron cavity (bubble) is formed behind the pulse. We show that for few-cycle laser pulses the cavity shape becomes asymmetric and depends strongly on the carrier-envelope phase. The carrier-envelope phase varies when the laser pulse propagates in plasma, which causes transverse oscillations of the cavity. Furthermore, the beam of electrons trapped by the cavity becomes modulated in the polarization plane. To describe these effects we derive an analytical model extended beyond the ponderomotive approximation. The degree of plasma cavity asymmetry as a function of the laser-plasma parameters is calculated. The obtained results are verified by particle-in-cell simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Investigation of the Rare Metal Content in the Geological Samples from Mongolia on the Iren Facility

Definition of the content of rare metals in the samples of ore was carried out by the method of the neutron activation analysis. IREN installation which represents the linear electron accelerator and no multiplying tungsten target served as the neutron source. The tungsten target has been located in the centre of the water moderator in diameter 15 cm.The irradiation has been spent on installation IREN within 8 hours 40 minutes. Electron energy was an order of 30 MeV, a current of an order 5 -10 microamperes. Samples settled down on the moderator surface. 2 samples of ore have been irradiated: Os-1 (m = 1.172 g), and Os-2 (m = 1.291 g) and a number of indicators for definition of neutron flux. Weights of indicators did not exceed a several milligrams.

07 ISOTOPE AND RADIATION SOURCES↗

Study of {sup 31}P(n,α){sup 28}Al reaction using d(d,n){sup 3}He for the possible interference with {sup 27}Al(n,γ){sup 28}Al - Paper 44

At McMaster we use neutrons from the {sup 7}Li(p,n){sup 7}Be reaction to measure aluminum in human subjects via the {sup 27}Al(n,γ){sup 28}Al reaction. We use proton energies of between 1.9 MeV and 2.3 MeV, yielding maximum neutron energy of 0.575 MeV. In principle, {sup 28}Al can also be produced via the {sup 31}P(n,α){sup 28}Al reaction, which has a neutron energy threshold of 2.008 MeV. When aluminum is measured in bone, there can be 10{sup 5} times the mass of phosphorus present as there is aluminum. However, this potential interference cannot arise using the {sup 7}Li(p,n){sup 7}Be reaction in the proton energy range specified. Collaborators at Atomic Energy of Canada Limited (AECL), Chalk River, Purdue University in the USA and Shanxi Medical University in Taiyuan, China are also interested in being able to measure aluminum in bone in living human subjects. Both AECL and Purdue have acquired D-D sets (accelerators producing neutrons via the d(d,n){sup 3}He reaction). These operate at high current (∼mA) and relatively low accelerating voltage (150 kV), relying on quantum mechanical tunneling through the Coulomb barrier. These D-D sets produce neutrons of energy 2.565 MeV. This is above the threshold for the {sup 31}P(n,α){sup 28}Al reaction, but we have not been able to find any report in which this reaction has had a cross section measurably greater than zero for neutron energies of less than 3 MeV. So, it is an open question as to whether the potential interfering reaction with phosphorus is a concern when using neutrons from a D-D set to measure aluminum in bone. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Rapid three-dimensional imaging of defect distributions using a high-intensity positron microbeam

An intense positron microbeam generated by an electron accelerator has been developed for obtaining three-dimensional positron lifetime mappings in a sample to permit visual evaluation of defect distributions. The beam diameter at the sample was 80-100 {mu}m. The counting rate of the positron annihilation {gamma} rays used to measure positron lifetime was as large as 3x10{sup 3} s{sup -1}. Three-dimensional imaging was demonstrated of positron lifetimes in a SiO{sub 2} sample, which was irradiated with ion beams through a mesh mask. The time to obtain a single image (3500 pixels for an area of 2.5x3.5 mm{sup 2}) was 0.5-1 h.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation of 500 MeV-1 GeV energy electrons from laser wakefield acceleration via ionization induced injection using CO{sub 2} mixed in He

Laser wakefield acceleration of 500 MeV to 1 GeV electron bunches has been demonstrated using ionization injection in mixtures of 4% to 10% of CO{sub 2} in He. 80 TW laser pulses were propagated through 5 mm gas jet targets at electron densities of 0.4-1.5 Multiplication-Sign 10{sup 19}cm{sup -3}. Ionization injection led to lower density thresholds, a higher total electron charge, and an increased probability of producing electrons above 500 MeV in energy compared to self-injection in He gas alone. Electrons with GeV energies were also observed on a few shots and indicative of an additional energy enhancement mechanism.

74 ATOMIC AND MOLECULAR PHYSICS↗

Residual Monte Carlo high-order solver for Moment-Based Accelerated Thermal Radiative Transfer equations

In this article we explore the possibility of replacing Standard Monte Carlo (SMC) transport sweeps within a Moment-Based Accelerated Thermal Radiative Transfer (TRT) algorithm with a Residual Monte Carlo (RMC) formulation. Previous Moment-Based Accelerated TRT implementations have encountered trouble when stochastic noise from SMC transport sweeps accumulates over several iterations and pollutes the low-order system. With RMC we hope to significantly lower the build-up of statistical error at a much lower cost. First, we display encouraging results for a zero-dimensional test problem. Then, we demonstrate that we can achieve a lower degree of error in two one-dimensional test problems by employing an RMC transport sweep with multiple orders of magnitude fewer particles per sweep. We find that by reformulating the high-order problem, we can compute more accurate solutions at a fraction of the cost.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cross sections for {alpha}-particle induced reactions on {sup 115,116}Sn around the Coulomb barrier

The cross sections of the {sup 115}Sn({alpha},{gamma}){sup 119}Te, {sup 115}Sn({alpha},n){sup 118}Te, and {sup 116}Sn({alpha},n){sup 119}Te reactions (both on ground and isomeric states) have been measured at effective center-of-mass energies from 9.3 to 14.8 MeV. During a first experiment, enriched self-supporting {sup 115}Sn (51.2%) + {sup 116}Sn (24.4%) foils were bombarded with an {alpha} beam delivered by the Bucharest IFIN-HH Tandem Accelerator. In a second experiment, a highly enriched {sup 116}Sn target was irradiated in order to disentangle the experimental cross section contributions due to {sup 115}Sn({alpha},{gamma}){sup 119}Te and {sup 115}Sn({alpha},n){sup 118}Te reactions obtained in the first measurement. The beam-induced activity was measured with two large volume HPGe detectors in close geometry. The experimental results were compared with theoretical predictions obtained in the framework of the statistical model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quench Simulation and Validation for EIC Direct Wind Magnets

The Electron-Ion Collider (EIC), a new facility to be built in the United States at the U.S. Department of Energy’s Brookhaven National Laboratory in collaboration with Thomas Jefferson National Accelerator Facility-will be the only new particle collider in the U.S. for the next 10∼20 years. The EIC project will investigate the origin of mass and building blocks of the Universe. It will accelerate and collide beams of electrons with protons and nuclei. Unlike any collider that has ever existed before, both EIC’s particle beams will be polarized, meaning their spins will be aligned in a controlled way to allow for precision measurements. Different types of new superconducting magnets will be required near the interaction region (IR) of EIC. A 6-around-1 NbTi cable will be used for some of those new superconducting magnets. Given the relatively smaller conductors used for those direct wind magnets, the overall engineering current density will be 2–3 times higher in comparison to traditional collared superconducting magnets in other accelerator magnets. This is technically challenging and potentially represents high risks for quench protection. Here, in this paper we use different tools and methods for quench simulation for several EIC direct wind magnets. We also present results of a sensitivity study, exploring different material properties and Jc curves. This paper also discusses and validates the quench simulation results with measurement results from a small-scale serpentine magnet tested at BNL in October 2024.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectroscopic observations of beam and source plasma light and testing Cs-deposition monitor in the large area negative ion source for LHD-NBI

In the large area negative ion source for the LHD negative-ion-(H{sup -})-based neutral beam system, (I) we used the spectrometer to measure caesium lines in the source plasma during beam shots. (II) With Doppler-shifted measurements, the H{sub {alpha}} line at three different locations along the beam as well as the spectrum profile for cases of different plasma grid areas. (III) Caesium deposition monitor with a high speed shutter was tested to measure the weight of the deposited Cs layer. In the observation, cleaner spectra of Doppler-shifted H{sub {alpha}} line with only a small level of background light were obtained at a new observation port which viewed the blueshifted light in the drift region after the accelerator of a LHD ion source. Both the amounts of Cs I (852 nm, neutral Cs{sup 0}) and Cs II (522 nm, Cs{sup +}) in the source plasma light rose sharply when beam acceleration began, and continued rising during a 10 s pulse. It was thought that this was because the cesium was evaporated/sputtered from the source back plate by the back-streaming positive ions. Cs deposition rate to the crystal sensor measured by adjusting the shutter open time was evaluated to be 2.9 nanograms/s cm{sup 2} for preliminary testing. More neutral Cs tended to be evolved in the source after arc discharge. Much Cs could be consumed in a high rate-pulsed operation (such as LHD source)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron ({sup 3}He) Spin Structure Functions at Low Q{sup 2}

Experiment E97-110 was performed at the Thomas Jefferson National Accelerator Facility to provide a precise measurement of the {sup 3}He spin structure functions at low Q{sup 2} from 0.02 to 0.3 [GeV/c]{sup 2}. A longitudinally-polarized electron beam was scattered from a longitudinally or transversely polarized {sup 3}He target. From these data, we have extracted moments of the neutron and {sup 3}He spin structure functions at very low momentum transfers. These data allow us to make a benchmark check of Chiral Perturbation Theory calculations in a region where they are expected to be valid. In these proceedings, the experimental details are discussed and preliminary results on the first moments of the g{sub 1} (x,Q{sup 2}) and g{sub 2} (x,Q{sup 2}) structure functions are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pound-Rebka experiment and torsion in the Schwarzschild spacetime

We develop some ideas discussed by E. Schucking [arXiv:0803.4128] concerning the geometry of the gravitational field. First, we address the concept according to which the gravitational acceleration is a manifestation of the space-time torsion, not of the curvature tensor. It is possible to show that there are situations in which the geodesic acceleration of a particle may acquire arbitrary values, whereas the curvature tensor approaches zero. We conclude that the space-time curvature does not affect the geodesic acceleration. Then we consider the Pound-Rebka experiment, which relates the time interval {delta}{tau}{sub 1} of two light signals emitted at a position r{sub 1}, to the time interval {delta}{tau}{sub 2} of the signals received at a position r{sub 2}, in a Schwarzschild type gravitational field. The experiment is determined by four space-time events. The infinitesimal vectors formed by these events do not form a parallelogram in the (t,r) plane. The failure in the closure of the parallelogram implies that the space-time has torsion. We find the explicit form of the torsion tensor that explains the nonclosure of the parallelogram.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energetic neutron beams generated from femtosecond laser plasma interactions

Experiments at the HERCULES laser facility have produced directional neutron beams with energies up to 16.8({+-}0.3) MeV using {sub 1}{sup 2}d(d,n){sub 2}{sup 3}He,{sub 7}{sup 3}Li(p,n){sub 4}{sup 7}Be,and{sub 3}{sup 7}Li(d,n){sub 4}{sup 8}Be reactions. Efficient {sub 1}{sup 2}Li(d,n){sub 4}{sup 8}Be reactions required the selective acceleration of deuterons through the introduction of a deuterated plastic or cryogenically frozen D{sub 2}O layer on the surface of a thin film target. The measured neutron yield was {<=}1.0 ({+-}0.5) Multiplication-Sign 10{sup 7} neutrons/sr with a flux 6.2({+-}3.7) times higher in the forward direction than at 90{sup Degree-Sign }. This demonstrates that femtosecond lasers are capable of providing a time averaged neutron flux equivalent to commercial {sub 1}{sup 2}d(d,n){sub 2}{sup 3}He generators with the advantage of a directional beam with picosecond bunch duration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pilot-wave hydrodynamics in a rotating frame: Exotic orbits

We present the results of a numerical investigation of droplets walking on a rotating vibrating fluid bath. The drop's trajectory is described by an integro-differential equation, which is simulated numerically in various parameter regimes. As the forcing acceleration is progressively increased, stable circular orbits give way to wobbling orbits, which are succeeded in turn by instabilities of the orbital center characterized by steady drifting then discrete leaping. In the limit of large vibrational forcing, the walker's trajectory becomes chaotic, but its statistical behavior reflects the influence of the unstable orbital solutions. The study results in a complete regime diagram that summarizes the dependence of the walker's behavior on the system parameters. Our predictions compare favorably to the experimental observations of Harris and Bush [“Droplets walking in a rotating frame: from quantized orbits to multimodal statistics,” J. Fluid Mech. 739, 444–464 (2014)].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-pulse enhanced laser ion acceleration using plasma half cavity targets

We report on a plasma half cavity target design for laser driven ion acceleration that enhances the laser to proton energy conversion efficiency and has been found to modify the low energy region of the proton spectrum. The target design utilizes the high fraction of laser energy reflected from an ionized surface and refocuses it such that a double pulse interaction is attained. We report on numerical simulations and experimental results demonstrating that conversion efficiencies can be doubled, compared to planar foil interactions, when the secondary pulse is delivered within picoseconds of the primary pulse.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of initial phase on error in electron energy obtained using paraxial approximation for a focused laser pulse in vacuum

We have investigated the effect of initial phase on error in electron energy obtained using paraxial approximation to study electron acceleration by a focused laser pulse in vacuum using a three dimensional test-particle simulation code. The error is obtained by comparing the energy of the electron for paraxial approximation and seventh-order correction description of the fields of Gaussian laser. The paraxial approximation predicts wrong laser divergence and wrong electron escape time from the pulse which leads to prediction of higher energy. The error shows strong phase dependence for the electrons lying along the axis of the laser for linearly polarized laser pulse. The relative error may be significant for some specific values of initial phase even at moderate values of laser spot sizes. The error does not show initial phase dependence for a circularly laser pulse.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗