Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Portable Rabies Virus Sequencing in Canine Rabies Endemic Countries Using the Oxford Nanopore MinION

As countries with endemic canine rabies progress towards elimination by 2030, it will become necessary to employ techniques to help plan, monitor, and confirm canine rabies elimination. Sequencing can provide critical information to inform control and vaccination strategies by identifying genetically distinct virus variants that may have different host reservoir species or geographic distributions. However, many rabies testing laboratories lack the resources or expertise for sequencing, especially in remote or rural areas where human rabies deaths are highest. We developed a low-cost, high throughput rabies virus sequencing method using the Oxford Nanopore MinION portable sequencer. A total of 259 sequences were generated from diverse rabies virus isolates in public health laboratories lacking rabies virus sequencing capacity in Guatemala, India, Kenya, and Vietnam. Phylogenetic analysis provided valuable insight into rabies virus diversity and distribution in these countries and identified a new rabies virus lineage in Kenya, the first published canine rabies virus sequence from Guatemala, evidence of rabies spread across an international border in Vietnam, and importation of a rabid dog into a state working to become rabies-free in India. Taken together, our evaluation highlights the MinION’s potential for low-cost, high volume sequencing of pathogens in locations with limited resources.

59 BASIC BIOLOGICAL SCIENCES↗

A Study on Computational Cost Reduction of Simulations of Phase-Change Material (PCM) Embedded Heat Exchangers

Thermal storage can be implemented using Phase-Change Materials (PCM), which absorb significant latent heat with a relatively small temperature change. PCM phase-change processes are transient and are driven by thermal diffusion and natural convection – the latter, especially for melting process. Modeling and simulation of PCM heat exchangers (HX’s) is typically computationally intensive due to the relatively complex time-dependent physics. Most of the PCM modeling work in the literature uses high-order modeling tools such as Computational Fluid Dynamics (CFD) and Lattice-Boltzmann Method (LBM). For design purposes, the existing PCM modeling approaches are not practical, limiting researchers in their ability to investigate new ideas and different PCM’s with faster turnarounds. This paper presents a study investigating the reduction of computational cost of PCM embedded HX’s CFD models by evaluating the feasibility of spatial reduction without losing accuracy. The analysis consists of comparing full and partial domain under full melting conditions. The subject of this study is a single straight tube with circular transverse fins in the vertical orientation, using PCM’s with 35oC nominal melting temperature. Different tube and fin dimensions are investigated. Results indicate that the reduced domain reproduces - in half the run time - the same behavior as the full domain since the buoyancy effects are localized and patterned. The outputs from the partial domain simulation were used to build a non-general correlation for the PCM heat transfer characteristics and demonstrated how it can be implemented in a Finite Control Volume Reduced Order Model (ROM). The ROM can accurately reproduce the CFD simulations at 4 to 5 orders of magnitude faster.

25 ENERGY STORAGE↗

Coupling a recurrent neural network to SPAD TCSPC systems for real-time fluorescence lifetime imaging

Fluorescence lifetime imaging (FLI) has been receiving increased attention in recent years as a powerful diagnostic technique in biological and medical research. However, existing FLI systems often suffer from a tradeoff between processing speed, accuracy, and robustness. Inspired by the concept of Edge Artificial Intelligence (Edge AI), we propose a robust approach that enables fast FLI with no degradation of accuracy. This approach couples a recurrent neural network (RNN), which is trained to estimate the fluorescence lifetime directly from raw timestamps without building histograms, to SPAD TCSPC systems, thereby drastically reducing transfer data volumes and hardware resource utilization, and enabling real-time FLI acquisition. We train two variants of the RNN on a synthetic dataset and compare the results to those obtained using center-of-mass method (CMM) and least squares fitting (LS fitting). Results demonstrate that two RNN variants, gated recurrent unit (GRU) and long short-term memory (LSTM), are comparable to CMM and LS fitting in terms of accuracy, while outperforming them in the presence of background noise by a large margin. To explore the ultimate limits of the approach, we derive the Cramer-Rao lower bound of the measurement, showing that RNN yields lifetime estimations with near-optimal precision. To demonstrate real-time operation, we build a FLI microscope based on an existing SPAD TCSPC system comprising a 32 x 32 SPAD sensor named Piccolo. Four quantized GRU cores, capable of processing up to 4 million photons per second, are deployed on the Xilinx Kintex-7 FPGA that controls the Piccolo. Powered by the GRU, the FLI setup can retrieve real-time fluorescence lifetime images at up to 10 frames per second. The proposed FLI system is promising and ideally suited for biomedical applications, including biological imaging, biomedical diagnostics, and fluorescence-assisted surgery, etc.

47 OTHER INSTRUMENTATION↗

Physical and Thermomechanical Properties of Yttrium Hydride from Large Scale Bulk Metal Hydriding Furnace

Given the superior thermal stability and highly attainable hydrogen density, yttrium hydride is an excellent high-temperature moderator material in advanced thermal neutron spectrum reactors that require small core volumes. Yttrium hydride has been selected as the moderator material for the Transformational Challenge Reactor, which was launched at Oak Ridge National Laboratory (ORNL) in 2019. However, fabrication of large-scale crack-free yttrium hydride is challenging and very limited efforts have been committed to the characterization of bulk yttrium hydride in response to the need to establish a complete database of the thermomechanical properties of YHx. In this report, the challenges associated with fabricating large-scale crack-free yttrium hydride are discussed herein. In response to those challenges, a hydriding system was designed and constructed at ORNL and was used to successfully fabricate crack-free yttrium hydride in complex geometries at large scales. This was accomplished by precisely controlling the hydrogen’s partial pressure and the retort temperature, which was informed by the well-established thermodynamic properties of the binary H-Y system. Hydrogen content in as-fabricated hydride was determined by the weight change method and vacuum hot extraction technique, complemented by the X-ray diffraction (XRD). In addition, significant efforts are being dedicated to establishing a complete database of the thermomechanical properties of as-fabricated yttrium hydride. In FY2020, we investigated the thermophysical properties of yttrium hydrides as a function of temperature (room temperature to 700°C) and hydrogen concentration (H/Y ratio ranges from 1.52 to 1.93). The results indicate that at the temperatures below 300 °C, the hydrogen content did not have a significant influence on the thermal expansion, while the specific heat capacity, the thermal diffusivity, and the calculated thermal conductivity were slightly higher for the higher H/Y ratio. Between 300°C and 700 °C, a reversible second-order endothermic transition in all measured thermal properties was observed. It was also found that the onset temperatures of the observed transition varied, with the composition having inverse dependence on the hydrogen content. An attempt was made to explain the behavior of the thermophysical properties at higher temperatures by considering the order– disorder transition as a result of hydrogen redistribution. In addition, nanoindentation was employed to determine the elastic modulus and hardness and to capture the crystal orientation dependence of these parameters. Vickers hardness was also reported. The final section of the report introduces ongoing neutron irradiation campaign of yttrium hydride.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Beam Dynamics of the Muon $g\textrm{-}2$ Experiment

The Muon $g\textrm{-}2$ Experiment (E989) at Fermilab aims to measure the muon anomalous magnetic moment $a_{\mu}$ with unprecedented precision, potentially uncovering physics beyond the Standard Model of particle physics. The result based on Runs 1-3, released in 2023, achieved a precision of 0.20 ppm. The experiment circulates muons in a storage ring, measuring $a_{\mu}$ from decay positron time and energy measurements collected with calorimeters. To achieve the required accuracy, it is crucial to measure and control the magnetic field in the ring with high precision. Beam dynamics corrections are necessary for muons not orbiting exactly in the midplane, for their oscillations, and for electric field effects. Highly accurate beam dynamics simulations are instrumental for quantifying and validating the beam dynamics corrections, ultimately improving the precision of the $a_{\mu}$ measurement and facilitating the achievement of the ambitious $70\:\mathrm{ppb}$ systematic uncertainty goal. The measured field data was incorporated into models for simulations using three codes: \texttt{gm2ringsim} (an internal Geant4-based code), \textit{COSY INFINITY}, and \textit{BMAD}. The advantages of \texttt{gm2ringsim} include using CAD-based geometry and modelling the detector effects. \textit{COSY INFINITY} is a highly accurate and efficient code that uses high-order differential-algebraic transfer maps, precise fringe field calculations, and advanced symplectification methods. Symplectification is important for maintaining the physical correctness of the muon beam behaviour with high precision over the storage time, ensuring conservation of phase space volume and preventing artificial damping or excitation of particle motion. The experiment completed its final Run 6 in July 2023, collecting 21 times more data than the previous BNL experiment. Analyses of data from Runs 4-6 are ongoing, with results planned for release in 2025, potentially resolving the current tension between experiment and theory.

43 PARTICLE ACCELERATORS↗

Screening and qualification methodology for SiC end plug processing methods

Deployment of SiC-ceramic-based fuel cladding for light water reactors requires a hermetic end plug–to–cladding joint that can withstand neutron irradiation during normal operation and maintain integrity during design-basis accidents. Reactor experiments have shown that some SiC composite tubes with SiC end plugs can retain hermeticity after irradiation. However, achieving consistent joint performance under irradiation remains a key challenge. Resolving this issue is essential to enable integral irradiation testing and to demonstrate fuel integrity under commercial-reactor irradiation conditions. This report aims to: (1) provide guidance for designing radiation-tolerant end plug joints for SiC cladding; (2) demonstrate experimental methods to detect processing defects that are unstable under neutron irradiation at light-water-reactor-relevant temperatures and doses; and (3) outline a step-by-step approach for designing and conducting reactor experiments to screen joining methods. The resulting data will be used to improve joint processing and to define critical defect types and sizes that must be detected and eliminated through non-destructive evaluation for quality assurance. Based on prior irradiation experiments at the High Flux Isotope Reactor, differential swelling among the cladding, bonding layer, and end plug was identified as an underlying mechanism for irradiation-induced joint degradation. Accordingly, this effect must be considered in the design of radiation-tolerant joining techniques. In this work, miniature SiC end plug joint specimens irradiated during the previous project were analyzed using X-ray computed tomography to characterize the joint microstructure. Digital volume correlation of the tomography data quantified radiation-induced microstructural changes and enabled evaluation of defect-related risks. Finally, ongoing neutron irradiation efforts using larger specimen volumes are presented. These efforts aim to statistically assess joint performance and to build a microstructure–performance (e.g., leak-tightness) dataset to inform processing improvements and quality control.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Avionics System Architecture for the NASA Orion Vehicle

It has been 30 years since the National Aeronautics and Space Administration (NASA) last developed a crewed spacecraft capable of launch, on-orbit operations, and landing. During that time, aerospace avionics technologies have greatly advanced in capability, and these technologies have enabled integrated avionics architectures for aerospace applications. The inception of NASA s Orion Crew Exploration Vehicle (CEV) spacecraft offers the opportunity to leverage the latest integrated avionics technologies into crewed space vehicle architecture. The outstanding question is to what extent to implement these advances in avionics while still meeting the unique crewed spaceflight requirements for safety, reliability and maintainability. Historically, aircraft and spacecraft have very similar avionics requirements. Both aircraft and spacecraft must have high reliability. They also must have as much computing power as possible and provide low latency between user control and effecter response while minimizing weight, volume, and power. However, there are several key differences between aircraft and spacecraft avionics. Typically, the overall spacecraft operational time is much shorter than aircraft operation time, but the typical mission time (and hence, the time between preventive maintenance) is longer for a spacecraft than an aircraft. Also, the radiation environment is typically more severe for spacecraft than aircraft. A "loss of mission" scenario (i.e. - the mission is not a success, but there are no casualties) arguably has a greater impact on a multi-million dollar spaceflight mission than a typical commercial flight. Such differences need to be weighted when determining if an aircraft-like integrated modular avionics (IMA) system is suitable for a crewed spacecraft. This paper will explore the preliminary design process of the Orion vehicle avionics system by first identifying the Orion driving requirements and the difference between Orion requirements and those of other previous crewed spacecraft avionics systems. Common systems engineering methods will be used to evaluate the value propositions, or the factors that weight most heavily in design consideration, of Orion and other aerospace systems. Then, the current Orion avionics architecture will be presented and evaluated.

Baggerman, Clint↗

A Simple Solution to a Complex Problem: Hexavalent Chromium in Landfill Storm water - 16129

Management of hexavalent chromium (Cr+6)-contaminated water at the Environmental Management Waste Management Facility (EMWMF) is a significant operational challenge, in addition to the challenges already posed by water management. The Cr+6 discharge criterion of 16 micrograms per liter (μg/L) is typically met; however, when demolition debris containing Cr+6 is received for disposal, concentrations up to 280 μg/L have been seen. The large volume of water generated at EMWMF from the 130-cm (51-in.) annual precipitation creates a complex water management problem that must be quickly addressed to maintain compliant landfill operations. The EMWMF Operations Team devised and implemented a simple, low-cost method to rapidly reduce the Cr+6 from the landfill storm water. The Cr+6 reduction system uses inexpensive, commercially available components of which the key is conventional steel wool in 760-L (200-gal) plastic bins. The Cr+6-impacted storm water is pumped through the bins, where the Cr+6 reacts with the elemental iron of the steel wool and reduces to trivalent chromium. The water then spills back into the ponds. Water is continuously recirculated through the bins until the release criterion is verified to be achieved, allowing the storm water to be discharged into the adjacent receiving stream. This cost-effective system is operated with in-house craft personnel, requiring only minimal additional training and hazard controls. The system can operate continuously with minimal intervention and has successfully processed millions of liters of storm water. The success of the initial installation has been refined over time, allowing Cr+6 reduction to proceed 24 hours a day and 7 days a week, with a Cr+6 reduction rate of about 20 μg/L per day. The system is scalable to achieve even higher reduction rates and adaptable to other metals. Through October 2015, over 65.1E6 L (17.2E6 gal) of contact water with Cr+6 above the release criterion was managed using the EMWMF system. This simple solution to a complex water management problem provides significant cost savings and operational efficiencies over traditional transportation and treatment at a water treatment facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stretchable nanocomposite electrodes with tunable mechanical properties by supersonic cluster beam implantation in elastomers

We demonstrate the fabrication of gold-polydimethylsiloxane nanocomposite electrodes, by supersonic cluster beam implantation, with tunable Young's modulus depending solely on the amount of metal clusters implanted in the elastomeric matrix. We show both experimentally and by atomistic simulations that the mechanical properties of the nanocomposite can be maintained close to that of the bare elastomer for significant metal volume concentrations. Moreover, the elastic properties of the nanocomposite, as experimentally characterized by nanoindentation and modeled with molecular dynamics simulations, are also well described by the Guth-Gold classical model for nanoparticle-filled rubbers, which depends on the presence, concentration, and aspect ratio of metal nanoparticles, and not on the physical and chemical modification of the polymeric matrix due to the embedding process. The elastic properties of the nanocomposite can therefore be determined and engineered a priori, by controlling only the nanoparticle concentration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New developments in the method of space-time conservation element and solution element: Applications to the Euler and Navier-Stokes equations

A new numerical framework for solving conservation laws is being developed. This new approach differs substantially in both concept and methodology from the well-established methods--i.e., finite difference, finite volume, finite element, and spectral methods. It is conceptually simple and designed to avoid several key limitations to the above traditional methods. An explicit model scheme for solving a simple 1-D unsteady convection-diffusion equation is constructed and used to illuminate major differences between the current method and those mentioned above. Unexpectedly, its amplification factors for the pure convection and pure diffusion cases are identical to those of the Leapfrog and the DuFort-Frankel schemes, respectively. Also, this explicit scheme and its Navier-Stokes extension have the unusual property that their stabilities are limited only by the CFL condition. Moreover, despite the fact that it does not use any flux-limiter or slope-limiter, the Navier-Stokes solver is capable of generating highly accurate shock tube solutions with shock discontinuities being resolved within one mesh interval. An accurate Euler solver also is constructed through another extension. It has many unusual properties, e.g., numerical diffusion at all mesh points can be controlled by a set of local parameters.

Chang, Sin-Chung↗

The Effect of Mission Location on Mission Costs and Equivalent System Mass

It is the goal of developers of advanced life support researcher to develop technology that reduces the cost of life support for future space missions and thereby enables missions that are currently infeasible or too expensive. Because the cost of propulsion dominates the cost of hardware emplacement in space and because the mass of a deliverable object controls its propulsive requirements, equivalent system mass (ESM) is used as a means for accounting for mission costs. ESM is typically calculated by adding to the actual mass the equivalent amount of mass that must be added to a mission due to other characteristics of a piece of hardware such as the item s volume or energy requirements. This approach works well for comparing different pieces of hardware when they go to the same location in space. However, different locations in mission space such low Earth orbit, Mars surface, or full trip to Mars and return to low Earth orbit require vastly different amounts of propulsion. Moving an object from Earth surface to the Martian surface and returning it to Earth will require as much as 100 times the propulsion that is required to move the object to low Earth orbit only. This paper presents the case for including the effect that location can have on cost as a part of ESM and suggests a method for achieving this improvement of ESM.

Fisher, John W.↗

Microstructure characteristics of LPBF&HIP fabricated graded composite transition joint between ferritic steel and austenitic stainless steel

Graded composite transition joints (GCTJs) offer a promising alternative to conventional dissimilar metal welds (DMWs) by enabling smooth compositional and microstructural transitions. However, GCTJs fabricated solely through additive manufacturing (AM) face challenges such as heat accumulation, complex parameter control, and elemental segregation. In this study, we propose a novel approach that relies on AM to design a spatially graded structure in one alloy and then employs hot isostatic pressing (HIP) as a diffusion bonding method to join it with a second alloy. Here, this method combines the flexibility of AM with the powder net-shaping advantage of HIP. Specifically, a series of closely packed austenitic stainless steel 304 conical structures were printed using laser powder bed fusion (LPBF) and then combined with ferritic steel P91 powder via HIP. By using electron backscatter diffraction (EBSD), electron probe microanalysis (EPMA), and transmission electron microscopy (TEM) techniques, the microstructure characteristics of the GCTJ of 304&P91, especially the interdiffusion zone (IDZ), have been systematically investigated. The microstructure at the interface transitions from austenite-ferrite (A+F) to austenite-martensite-ferrite (A+M+F), and finally to martensite-ferrite (M+F) due to diffusion. Additionally, the diffusion width between 304 and P91 increases with the volume fraction of P91. This unique design also ensures a gradual transition in both hardness and thermal expansion coefficient from 304 to P91, thereby enabling a smooth gradient in functional properties. Overall, this study proposes a novel approach for fabricating GCTJs and contributes to advancing design concepts in the field of dissimilar metal joining.

Additively manufacturing (AM)↗

TU-F-CAMPUS-I-04: Head-Only Asymmetric Gradient System Evaluation: ACR Image Quality and Acoustic Noise

Purpose: A high-performance head-only magnetic resonance imaging gradient system with an acquisition volume of 26 cm employing an asymmetric design for the transverse coils has been developed. It is able to reach a magnitude of 85 mT/m at a slew rate of 700 T/m/s, but operated at 80 mT/m and 500 T/m/s for this test. A challenge resulting from this asymmetric design is that the gradient nonlinearly exhibits both odd- and even-ordered terms, and as the full imaging field of view is often used, the nonlinearity is pronounced. The purpose of this work is to show the system can produce clinically useful images after an on-site gradient nonlinearity calibration and correction, and show that acoustic noise levels fall within non-significant risk (NSR) limits for standard clinical pulse sequences. Methods: The head-only gradient system was inserted into a standard 3T wide-bore scanner without acoustic damping. The ACR phantom was scanned in an 8-channel receive-only head coil and the standard American College of Radiology (ACR) MRI quality control (QC) test was performed. Acoustic noise levels were measured for several standard pulse sequences. Results: Images acquired with the head-only gradient system passed all ACR MR image quality tests; Both even and odd-order gradient distortion correction terms were required for the asymmetric gradients to pass. Acoustic noise measurements were within FDA NSR guidelines of 99 dBA (with assumed 20 dBA hearing protection) A-weighted and 140 dB for peak for all but one sequence. Note the gradient system was installed without any shroud or acoustic batting. We expect final system integration to greatly reduce noise experienced by the patient. Conclusion: A high-performance head-only asymmetric gradient system operating at 80 mT/m and 500 T/m/s conforms to FDA acoustic noise limits in all but one case, and passes all the ACR MR image quality control tests. This work was supported in part by the NIH grant 5R01EB010065.

60 APPLIED LIFE SCIENCES↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Novel method to control explosive shock sensitivity: A mesoscale study to understand the effect of thermally expandable microsphere (TEM) inclusions in high explosives (HE) microstructure

When the void content and/or void structure of a high explosive (HE) is altered by some means (i.e., bulk heating or mechanical damage), the shock initiation behavior of the material changes. The ability to precisely predict the change in shock sensitivity after an HE has undergone microstructural changes is a crucial capability in multi-scale reactive flow models. Here, we utilize thermally expandable microspheres (TEMs) as a dopant in a polymer bonded explosive (PBX) matrix to alter the shock initiation properties in a controlled fashion. Here, using a mesoscale modeling approach, we evaluated how a single TEM (before and after thermal expansion) behaves under shock compression, as well as how the matrix PBX in the direct vicinity of the TEM is affected. We first examined the effect of an unexpanded TEM in the explosive matrix and found that its presence does not significantly perturb the bulk flow and by extension will not affect bulk sensitivity. Next, we examined the effect of an expanded TEM and found that its presence significantly perturbs the flow via hydrodynamic jetting, which causes a secondary shock wave with a strength that exceeds that of the incident wave. Finally, we showed that this secondary shock interacts with the downstream porosity to ignite a larger fraction of the overall pore volume, commensurate with the secondary shock strength and the affected volume, increasing the global (bulk) shock sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Control of High-Temperature Static and Transient Thermomechanical Behavior of SiMo Ductile Iron by Al Alloying

Abstract Silicon and molybdenum ( SiMo ) ductile iron is commonly used for exhaust manifolds because these components experience thermal cycling in oxidizing environment, which requires resistance to fatigue during transient thermomechanical loads. Previous studies have demonstrated that alloying elements, such as Al , to SiMo ductile iron reduces the amount of surface degradation during static high-temperature exposure. However, deterioration of sphericity of the graphite nodules and a decrease in ductility could affect the tendency of cracking during thermal cycling. In this article, the effect of Al alloying on static and transient thermomechanical behavior of SiMo ductile iron was investigated to optimize the amount of Al alloying. A thermodynamic approach was used to confirm the effect of the Al alloying on the phase transformations in two SiMo cast irons, alloyed by 1.8% Al and 3% Al . These two alloys were cast in a laboratory along with the baseline SiMo ductile iron. Several experimental methods were used to evaluate the dimensional stability, physical properties, static oxidation, and failure resistance during constrained thermal cycling testing to compare their high-temperature capability. Experimental results verified that Al alloying increases the temperature range and decreases volume change during eutectoid transformation, which together with enhancement of oxidation protection improved the dimensional stability. Thermocycling tests showed that the number of cycles to failure depends on the amount of Al alloying and the applied high-temperature exposure during each cycle. SEM/EDX, high-resolution TEM and µCT analysis were used to verify the mechanism resulting from the Al alloying protection. It was shown that an optimal level of Al alloying for balancing oxidation and thermal cracking resistance depends on thermomechanical conditions of application.

36 MATERIALS SCIENCE↗

BrainXcan identifies brain features associated with behavioral and psychiatric traits using large-scale genetic and imaging data

Advances in brain MRI have enabled many discoveries in neuroscience. Case-control comparisons of brain MRI features have highlighted potential causes of psychiatric and behavioral disorders. However, due to the cost and difficulty of collecting MRI data, most studies have small sample sizes, limiting their reliability. Furthermore, reverse causality complicates interpretation because many observed brain differences are the result rather than the cause of the disease. Here we propose a method (BrainXcan) that leverages the power of large-scale genomewide association studies (GWAS) and reference brain MRI data to discover new mechanisms of disease etiology and validate existing ones. BrainXcan tests the association with genetic predictors of brain MRI-derived features and complex traits to pinpoint relevant brain-wide and region-specific features. Requiring only genetic data, BrainXcan allows us to test a host of hypotheses on mental illness, across many MRI modalities, using public data resources. For example, our method shows that reduced axonal density across the brain is associated with schizophrenia risk, consistent with the disconnectivity hypothesis. We also find that the hippocampus volume is associated with schizophrenia risk, highlighting the potential of our approach. Taken together, our results show the promise of BrainXcan to provide insights into the biology of GWAS traits.

Association study↗

Establishing High-Quality Prostate Brachytherapy Using a Phantom Simulator Training Program

Purpose: To design and implement a unique training program that uses a phantom-based simulator to teach the process of prostate brachytherapy (PB) quality assurance and improve the quality of education. Methods and Materials: Trainees in our simulator program were practicing radiation oncologists, radiation oncology residents, and fellows of the American Brachytherapy Society. The program emphasized 6 core areas of quality assurance: patient selection, simulation, treatment planning, implant technique, treatment evaluation, and outcome assessment. Using the Iodine 125 ({sup 125}I) preoperative treatment planning technique, trainees implanted their ultrasound phantoms with dummy seeds (ie, seeds with no activity). Pre- and postimplant dosimetric parameters were compared and correlated using regression analysis. Results: Thirty-one trainees successfully completed the simulator program during the period under study. The mean phantom prostate size, number of seeds used, and total activity were generally consistent between trainees. All trainees met the V100 >95% objective both before and after implantation. Regardless of the initial volume of the prostate phantom, trainees' ability to cover the target volume with at least 100% of the dose (V100) was not compromised (R=0.99 pre- and postimplant). However, the V150 had lower concordance (R=0.37) and may better reflect heterogeneity control of the implant process. Conclusions: Analysis of implants from this phantom-based simulator shows a high degree of consistency between trainees and uniformly high-quality implants with respect to parameters used in clinical practice. This training program provides a valuable educational opportunity that improves the quality of PB training and likely accelerates the learning curve inherent in PB. Prostate phantom implantation can be a valuable first step in the acquisition of the required skills to safely perform PB.

62 RADIOLOGY AND NUCLEAR MEDICINE↗