Search NASA⌕ Search

SEARCH · Search NASA

Results for “data conversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

R&D for Safety Codes and Standards: Materials and Components Compatibility

This project addresses the following technical barriers from the Safety, Codes and Standards section of the 2012 Fuel Cell Technologies Office Multi-Year Research, Development and Demonstration Plan (section 3.8): (A) Safety data and information: limited access and availability (F) Enabling national and international markets requires consistent RCS (G) Insufficient technical data to revise standards.

30 DIRECT ENERGY CONVERSION↗

The effect of replacement of Sr by Ca on the structural and luminescence properties of the red-emitting Sr{sub 2}Si{sub 5}N{sub 8}:Eu{sup 2+} LED conversion phosphor

The influence of the replacement of Sr by Ca on structural and luminescence properties of Eu{sup 2+}-doped Sr{sub 2}Si{sub 5}N{sub 8} is reported. The Rietveld refinement of the powder X-ray diffraction data shows that the Ca{sup 2+} ion preferentially occupies the larger Sr site in Sr{sub 2}Si{sub 5}N{sub 8}:Eu{sup 2+}. Although the excitation spectrum is hardly modified, the position of the emission band of Eu{sup 2+} can be tailored through partial replacement of Sr by Ca in Sr{sub 2}Si{sub 5}N{sub 8}:Eu{sup 2+}, resulting in red-emission shifting from 620 to 643 nm. Furthermore, (Sr, Ca){sub 2}Si{sub 5}N{sub 8}:Eu{sup 2+} shows high potential as a conversion phosphor for white-light LED applications due to similar absorption, conversion efficiency and thermal quenching behaviour for 465 nm excitation after the introduction of the Ca ion. - Graphical abstract: The temperature dependence of the luminescence efficiency of M{sub 1.9}Eu{sub 0.1}Si{sub 5}N{sub 8} (M=Ca, Sr, Ba) and Sr{sub 1.3}Ca{sub 0.6}Eu{sub 0.1}Si{sub 5}N{sub 8} ({lambda}{sub exc}=465 nm)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scrape-off layer reflectometer for Alcator C-Mod

A swept-frequency X-mode reflectometer is being built for Alcator C-Mod to measure the scrape-off layer density profiles at the top, middle, and bottom locations in front of both the new lower hybrid launcher and the new ion cyclotron range of frequencies antenna. The system is planned to operate between 100 and 146 GHz at sweep rates from 10 {mu}s to 1 ms, and will cover a density range of approximately 10{sup 16}-10{sup 20} m{sup -3} at B{sub 0}=5-5.4 T. To minimize the effects of density fluctuations, both differential phase and full phase reflectometry will be employed. Design, test data, and calibration results of this electronics system will be discussed. To reduce attenuation losses, tallguide (TE{sub 01}) will be used for most of the transmission line system. Simulations of high mode conversion in tallguide components, such as e-plane hyperbolic secant radius of curvature bends, tapers, and horn antennas will be shown. Experimental measurements of the total attenuation losses of these components in the lower hybrid waveguide run will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AMS Ground Truth Measurements: Calibration and Test Lines

Airborne gamma spectrometry is one of the primary techniques used to define the extent of ground contamination after a radiological incident. Its usefulness was demonstrated extensively during the response to the Fukushima nuclear power plant (NPP) accident in March-May 2011. To map ground contamination a set of scintillation detectors is mounted on an airborne platform (airplane or helicopter) and flown over contaminated areas. The acquisition system collects spectral information together with the aircraft position and altitude every second. To provide useful information to decision makers, the count rate data expressed in counts per second (cps) needs to be converted to the terrestrial component of the exposure rate 1 m above ground, or surface activity of isotopes of concern. This is done using conversion coefficients derived from calibration flights. During a large scale radiological event, multiple flights may be necessary and may require use of assets from different agencies. However, as the production of a single, consistent map product depicting the ground contamination is the primary goal, it is critical to establish very early into the event a common calibration line. Such a line should be flown periodically in order to normalize data collected from different aerial acquisition systems and potentially flown at different flight altitudes and speeds. In order to verify and validate individual aerial systems, the calibration line needs to be characterized in terms of ground truth measurements. This is especially important if the contamination is due to short-lived radionuclides. The process of establishing such a line, as well as necessary ground truth measurements, is described in this document.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data-driven Community-centered Resilient Assessment and Planning Toolkit for Nexus of Energy and Water (DCRAPT-NEW)

Urban areas, including Detroit and Pittsburgh, have suffered significant dual outages of the electrical and water infrastructure in the past decade due, in part, to the increasing number of extreme weather events. With increasing temperatures and rainfall intensity, these regions need to prepare for increasing extreme events through community-based energy and water resilience analysis, planning, and enhancement. This project developed a suite of open-source, open-access, community-centered, data-driven assessment and distributed energy resource (DER) and planning tools for energy and water resilience enhancement in urban areas. Through establishing a multi-level community awareness and engagement mechanism and a comprehensive collection of power outage and flooding data, an innovative group of community energy and water resilience assessment and planning tools have been developed for a wide range of users with differing and variable sets of data available to them. The developed tools include (1) DOE EAGLE-I data-driven, deep-learning assisted resilience assessment and DER planning tools at the county level with socioeconomic factors incorporated; (2) Utility annual power outage data-driven tools for long term resilience assessment and DER planning and 15-min power outage data-driven tools for short term resilience assessment and planning; (3) Detailed engineering tools for energy and water systems resilience assessment and planning when the system topology and component fragility curves are available; (4) Alternative Resiliency Metric Calculation that extracts and separates outage and restoration processes; and (5) Co-optimization tools that evaluate the resilience of the power and sewage system and allow users to conduct joint planning with energy and wastewater systems. The developed tools provide planners, decision-makers, and stakeholders with powerful capabilities to systematically evaluate system/community resilience and optimal and actionable guidance for enhancing resilience while prioritizing DER investments. The tools have been used and validated in Detroit and Pittsburgh and can be used in other areas of the nation. In addition, this project will (1) advance the knowledge and applications of machine-learning methods in analyzing and fusing different layers of information and generating meaningful data points such as generating rare weather events; (2) significantly improve the energy and water resilience of the identified communities in Detroit and Pittsburgh and prepare for more frequent and severe weather conditions; (3) help communities assess extreme weather event impacts and address short-term and long-term resilience-related issues The developed tools have been made public via GitHub and demonstrated to community stakeholders and utility companies via the two annual workshops and numerous community engagement meetings. The project outcomes are also disseminated through publications in various journals and conference proceedings, and presentations at top conferences.

13 HYDRO ENERGY↗

AMS Ground Truth Measurements: Calibrations and Test Lines

Airborne gamma spectrometry is one of the primary techniques used to define the extent of ground contamination after a radiological incident. Its usefulness was demonstrated extensively during the response to the Fukushima NPP accident in March-May 2011. To map ground contamination, a set of scintillation detectors is mounted on an airborne platform (airplane or helicopter) and flown over contaminated areas. The acquisition system collects spectral information together with the aircraft position and altitude every second. To provide useful information to decision makers, the count data, expressed in counts per second (cps), need to be converted to a terrestrial component of the exposure rate at 1 meter (m) above ground, or surface activity of the isotopes of concern. This is done using conversion coefficients derived from calibration flights. During a large-scale radiological event, multiple flights may be necessary and may require use of assets from different agencies. However, because production of a single, consistent map product depicting the ground contamination is the primary goal, it is critical to establish a common calibration line very early into the event. Such a line should be flown periodically in order to normalize data collected from different aerial acquisition systems and that are potentially flown at different flight altitudes and speeds. In order to verify and validate individual aerial systems, the calibration line needs to be characterized in terms of ground truth measurements This is especially important if the contamination is due to short-lived radionuclides. The process of establishing such a line, as well as necessary ground truth measurements, is described in this document.

airborne platform↗

Isotopic dependence of the cross section for the induced fission of heavy nuclei

The cross sections for the induced fission of {sup 211-223}Ra, {sup 203-211}Rn, and {sup 221-231}Th nuclei undergoing peripheral collisions with {sup 208}Pb nuclei are calculated on the basis of the statistical model. The role of the N = 126 neutron shell is studied. The level density in excited nuclei is determined within the Fermi gas model and a model that takes into account the collective enhancement of the level density. The inclusion of a particle-hole excitation in addition to a collective Coulomb excitation makes it possible to obtain a satisfactory description of experimental cross sections for the fission of radium isotopes. The calculated ratios of the cross sections for the induced fission of {sup 236}U ({sup 237}U) and {sup 238}U ({sup 239}U) nuclei agree with experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast soft x-ray images of magnetohydrodynamic phenomena in NSTX

A variety of magnetohydrodynamic (MHD) phenomena have been observed on NSTX. Many of these affect fast particle losses, which are of major concern for future burning plasma experiments. Usual diagnostics for studying these phenomena are arrays of Mirnov coils for magnetic oscillations and p-i-n diode arrays for soft x-ray emission from the plasma core. Data reported here are from a unique fast soft x-ray imaging camera (FSXIC) with a wide-angle (pinhole) tangential view of the entire plasma minor cross section. The camera provides a 64x64 pixel image, on a charge coupled device chip, of light resulting from conversion of soft x rays incident on a phosphor to the visible. We have acquired plasma images at frame rates of 1-500 kHz (300 frames/shot) and have observed a variety of MHD phenomena: disruptions, sawteeth, fishbones, tearing modes, and edge localized modes (ELMs). New data including modes with frequency >90 kHz are also presented. Data analysis and modeling techniques used to interpret the FSXIC data are described and compared, and FSXIC results are compared to Mirnov and p-i-n diode array results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast soft x-ray images of magnetohydrodynamic phenomena in NSTX

A variety of magnetohydrodynamic (MHD) phenomena have been observed on NSTX. Many of these affect fast particle losses, which are of major concern for future burning plasma experiments. Usual diagnostics for studying these phenomena are arrays of Mirnov coils for magnetic oscillations and p-i-n diode arrays for soft x-ray emission from the plasma core. Data reported here are from a unique fast soft x-ray imaging camera (FSXIC) with a wide-angle (pinhole) tangential view of the entire plasma minor cross section. The camera provides a 64x64 pixel image, on a charge coupled device chip, of light resulting from conversion of soft x rays incident on a phosphor to the visible. We have acquired plasma images at frame rates of 1-500 kHz (300 frames/shot) and have observed a variety of MHD phenomena: disruptions, sawteeth, fishbones, tearing modes, and edge localized modes (ELMs). New data including modes with frequency >90 kHz are also presented. Data analysis and modeling techniques used to interpret the FSXIC data are described and compared, and FSXIC results are compared to Mirnov and p-i-n diode array results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

IGFBP3 and BAG1 enhance radiation-induced apoptosis in squamous esophageal cancer cells

Research highlights: {yields} TE-12 cell had greater radiosensitivity and higher levels of caspase 3/7 activity for radiotherapy than TE-5 or TE-9 cells. {yields} The expression of IGFBP3 and BAG1 was five or more times higher in TE-12 cell in DNA microarrays analysis. {yields} Knocking down IGFBP3 and/or BAG1 expression using targeted siRNA diminished their susceptibility to radiation. -- Abstract: Identification of reliable markers of radiosensitivity and the key molecules that enhance the susceptibility of esophageal cancer cells to anticancer treatments would be highly desirable. To identify molecules that confer radiosensitivity to esophageal squamous carcinoma cells, we assessed the radiosensitivities of the TE-5, TE-9 and TE-12 cloneA1 cell lines. TE-12 cloneA1 cells showed significantly greater susceptibility to radiotherapy at 5 and 10 Gy than either TE-5 or TE-9 cells. Consistent with that finding, 24 h after irradiation (5 Gy), TE-12 cloneA1 cells showed higher levels of caspase 3/7 activity than TE-5 or TE-9 cells. When we used DNA microarrays to compare the gene expression profiles of TE-5 and TE-12 cloneA1 cells, we found that the mRNA and protein expression of insulin-like growth factor binding protein 3 (IGFBP3) and Bcl-2-associated athanogene 1 (BAG1) was five or more times higher in TE-12 cloneA1 cells than TE-5 cells. Conversely, knocking down expression of IGFBP3 and BAG1 mRNA in TE-12 cloneA1 cells using small interfering RNA (siRNA) significantly reduced radiosensitivity. These data suggest that IGFBP3 and BAG1 may be key markers of radiosensitivity that enhance the susceptibility of squamous cell esophageal cancer to radiotherapy. IGFBP3 and BAG1 may thus be useful targets for improved and more individualized treatments for patients with esophageal squamous cell carcinoma.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Lattice crossover and mixed valency in the LaCo{sub 1-x}Rh{sub x}O{sub 3} solid solution

The full LaCo{sub 1-x}Rh{sub x}O{sub 3} solid solution was investigated utilizing structural, electrical transport, magnetic, and thermal conductivity characterization. Strong evidence for at least some conversion of Rh{sup 3+}/Co{sup 3+} to Rh{sup 4+}/Co{sup 2+} is found in both structural and electrical transport data. The crystal structure is that of a rhombohedrally distorted perovskite over the range 0.0{<=}x{<=}0.1. The common orthorhombic distortion of the perovskite structure is found over the range 0.2{<=}x{<=}1.0. A crossover of all three orthorhombic cell edges occurs at x=0.5 giving the appearance of a cubic structure, which actually remains orthorhombic. The octahedra in the orthorhombic structure must be distorted for x values less than 0.5, and the observed distortion suggests orbital ordering for Co{sup 2+}. Electrical resistivity measurements as a function of temperature show semiconducting-like regions for all compositions. There is a steady increase in electrical resistivity as the Rh content increases. Large positive thermopower values are generally obtained above 475 K. With increasing Rh substitution there is a decrease in thermal conductivity, which slowly rises with increasing temperature due to increased electrical conductivity. The electronic part of the thermal conductivity is suppressed significantly upon Rh substitution. A thermoelectric figure-of-merit (ZT) of about 0.075 has been achieved for LaCo{sub 0.5}Rh{sub 0.5}O{sub 3} at 775 K, and is expected to reach 0.15 at 1000 K. - Graphical abstract: A complete solid solution is formed between LaCoO{sub 3} and LaRhO{sub 3}. The effect of Rh substitution for Co on the lattice crossover, mixed valency and physical properties is described.

36 MATERIALS SCIENCE↗

Simplified one-dimensional calculation of 13.5 nm emission in a tin plasma including radiation transport

Many next generation lithography schemes for the semiconductor industry are based on a 13.5 nm tin plasma light source, where hundreds of thousands of 4d-4f, 4p-4d, and 4d-5p transitions from Sn{sup 5+}-Sn{sup 13+} ions overlap to form an unresolved transition array. To aid computation, transition arrays are treated statistically, and Hartree-Fock results are used to calculate radiation transport in the optically thick regime with a one-dimensional Lagrangian plasma hydrodynamics code. Time-dependent spectra and conversion efficiencies of 2% in-band 13.5 nm emission to laser energy are predicted for a Nd:YAG (yttrium aluminum garnet) laser incident on a pure tin slab target as a function of laser power density and pulse duration at normal incidence. Calculated results showed a maximum conversion efficiency of 2.3% for a 10 ns pulse duration at 8.0x10{sup 10} W/cm{sup 2} and are compared to experimental data where available. Evidence for the need to include lateral expansion is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multichannel low power time-to-digital converter card with 21 ps precision and full scale range up to 10 μs

We present a Time-to-Digital Converter (TDC) card with a compact form factor, suitable for multichannel timing instruments or for integration into more complex systems. The TDC Card provides 10 ps timing resolution over the whole measurement range, which is selectable from 160 ns up to 10 μs, reaching 21 ps rms precision, 1.25% LSB rms differential nonlinearity, up to 3 Mconversion/s with 400 mW power consumption. The I/O edge card connector provides timing data readout through either a parallel bus or a 100 MHz serial interface and further measurement information like input signal rate and valid conversion rate (typically useful for time-correlated single-photon counting application) through an independent serial link.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the inhomogeneity of the KATRIN tritium source electric potential by high-resolution spectroscopy of conversion electrons from $\mathbf {^{83m}}$Kr

Precision spectroscopy of the electron spectrum of the tritium β-decay near the kinematic endpoint is a direct method to determine the effective electron antineutrino mass. The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to determine this quantity with a sensitivity of better than 0.3 eV (90% C.L.). An inhomogeneous electric potential in the tritium source of KATRIN can lead to distortions of the β-spectrum, which directly impact the neutrino-mass observable. This effect can be quantified through precision spectroscopy of the conversion-electrons of co-circulated metastable 83m Kr. Therefore, dedicated, several-weeks long measurement campaigns have been performed within the KATRIN data taking schedule. In this work, we infer the tritium source potential observables from these measurements, and present their implications for the neutrino-mass determination.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GDX-pandas [SWR 15-21]

This is a Python package to translate between gdx (GAMS data) and pandas. There are two main ways to use gdxpds. The first use case is the one that was initially supported: direct conversion between GDX files on disk and pandas DataFrames or a csv version thereof. Starting with the Version 1.0.0 rewrite, there is now a second style of use which involves interfacing with GDX files and symbols via the `gdxpds.gdx.GdxFile` and `gdxpds.gdx.GdxSymbol` classes. Please visit https://nrel.github.io/gdx-pandas for the latest documentation.

Hale, Elaine↗

drtsans

drtsans is highly modular, allowing users to customize collected data as well as test hypothetical or simulated neutron events data. Instrument scientists can use the advance features of drtsans to calibrate their instruments and reduced large quantities of datasets in a streamlined mode. Users can correct the collected data with dark current subtraction and normalization by neutron flux, detector sensitivity, solid angle subtended by the detectors, and scaling to absolute units. Conversion from time-of-flight and/or wavelength to 1D or 2D momentum transfer renders the final scattering quantities amenable to analysis.

Bilheux, JeanC↗

Next generation sequencing (NGS) technologies and applications [Slides]

NGS technology overview: (1) NGS library preparation - Nucleic acids extraction, Sample quality control, RNA conversion to cDNA, Addition of sequencing adapters, Quality control of library; (2) Sequencing - Clonal amplification of library fragments, (except PacBio), Sequencing by synthesis, Data output (reads and quality); and (3) Data analysis - Read mapping, Genome assembly, Gene expression, Operon structure, sRNA discovery, and Epigenetic analyses.

59 BASIC BIOLOGICAL SCIENCES↗