At least 1,153 records · Page 64

An exactly solvable deformation of the Coulomb problem associated with the Taub–NUT metric

In this paper we quantize the N-dimensional classical Hamiltonian system H=(|q|)/(2(η+|q|)) p{sup 2}−k/(η+|q|) , that can be regarded as a deformation of the Coulomb problem with coupling constant k, that it is smoothly recovered in the limit η→0. Moreover, the kinetic energy term in H is just the one corresponding to an N-dimensional Taub–NUT space, a fact that makes this system relevant from a geometric viewpoint. Since the Hamiltonian H is known to be maximally superintegrable, we propose a quantization prescription that preserves such superintegrability in the quantum mechanical setting. We show that, to this end, one must choose as the kinetic part of the Hamiltonian the conformal Laplacian of the underlying Riemannian manifold, which combines the usual Laplace–Beltrami operator on the Taub–NUT manifold and a multiple of its scalar curvature. As a consequence, we obtain a novel exactly solvable deformation of the quantum Coulomb problem, whose spectrum is computed in closed form for positive values of η and k, and showing that the well-known maximal degeneracy of the flat system is preserved in the deformed case. Several interesting algebraic and physical features of this new exactly solvable quantum system are analyzed, and the quantization problem for negative values of η and/or k is also sketched.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multikink solutions and deformed defects

In this work we consider an application of the deformation procedure that enables us to construct, systematically, scalar field models supporting multikinks. We introduce a new deformation function in order to realize this task. We exemplify the procedure with three different starting models already known in the literature, and the resulting deformed models have rich minima structures which are responsible for the appearance of multikink configurations. We have also considered an application to braneworld scenarios, where we have obtained interesting configurations corresponding to the multikink solutions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the effect of x-ray irradiation on the deformation and fracture behavior of human cortical bone

In situ mechanical testing coupled with imaging using high-energy synchrotron x-ray diffraction or tomography imaging is gaining in popularity as a technique to investigate micrometer and even sub-micrometer deformation and fracture mechanisms in mineralized tissues, such as bone and teeth. However, the role of the irradiation in affecting the nature and properties of the tissue is not always taken into account. Accordingly, we examine here the effect of x-ray synchrotron-source irradiation on the mechanistic aspects of deformation and fracture in human cortical bone. Specifically, the strength, ductility and fracture resistance (both work-of-fracture and resistance-curve fracture toughness) of human femoral bone in the transverse (breaking) orientation were evaluated following exposures to 0.05, 70, 210 and 630 kGy irradiation. Our results show that the radiation typically used in tomography imaging can have a major and deleterious impact on the strength, post-yield behavior and fracture toughness of cortical bone, with the severity of the effect progressively increasing with higher doses of radiation. Plasticity was essentially suppressed after as little as 70 kGy of radiation; the fracture toughness was decreased by a factor of five after 210 kGy of radiation. Mechanistically, the irradiation was found to alter the salient toughening mechanisms, manifest by the progressive elimination of the bone's capacity for plastic deformation which restricts the intrinsic toughening from the formation 'plastic zones' around crack-like defects. Deep-ultraviolet Raman spectroscopy indicated that this behavior could be related to degradation in the collagen integrity.

36 MATERIALS SCIENCE↗

A fluid pressure and deformation analysis for geological sequestration of carbon dioxide

We present a hydro-mechanical model and deformation analysis for geological sequestration of carbon dioxide. The model considers the poroelastic effects by taking into account the two-way coupling between the geomechanical response and the fluid flow process in greater detail. In order for analytical solutions, the simplified hydro-mechanical model includes the geomechanical part that relies on the theory of linear elasticity, while the fluid flow is based on the Darcy’s law. The model was derived through coupling the two parts using the standard linear poroelasticity theory. Analytical solutions for fluid pressure field were obtained for a typical geological sequestration scenario and the solutions for ground deformation were obtained using the method of Green’s function. Solutions predict the temporal and spatial variation of fluid pressure, the effect of permeability and elastic modulus on the fluid pressure, the ground surface uplift, and the radial deformation during the entire injection period.

54 ENVIRONMENTAL SCIENCES↗

Molecular level study of uni/multi-axial deformation response of tobermorite 11 Å: A force field comparison study

Molecular deformation response of tobermorite 11 Å (a mineral analogue to C-S-H, the primary constituent of hydrated cement paste) under uni/tri-axial loading (both tension and compression) has been investigated in this manuscript using empirical and reactive force fields. A comparison has been chalked out amongst the responses using different force fields. Evolution of atomic environment during the deformation have studied using reactive force field. This study demonstrate the key observations on the application of different force fields to study the large deformation behaviour of the material.

36 MATERIALS SCIENCE↗

Rate-dependent strength and deformation heterogeneity of B4C-reinforced Al composite: Time-resolved imaging with synchrotron X-rays

Dynamic (up to 5500 s -1 ) and quasi-static compression tests are conducted on a 15 wt% B4C particle-reinforced Al (B 4 C/Al) composite. In situ, high-speed synchrotron X-ray phase contrast imaging and digital image correlation are employed to map mesoscale deformation fields at μm and μs scales. The bulk stress–strain curves show significant strain and strain-rate hardening under dynamic compression. The strain-rate sensitivity exponent is an order of magnitude higher at high strain rates (> 10 3 s -1 ) than that at low strain rates (< 10 -2 s -1 ). Strain field mapping demonstrates distinct compressive strain localizations for both quasi-static and dynamic loading. Nevertheless, compressive strain localizations appear denser in spacing under dynamic loading, owing to spontaneous dislocation nucleation in both weak and strong zones. This results in a higher density of geometrically necessary dislocations, which contributes to the higher strain and strain-rate hardening of B 4 C/Al under dynamic loading. Additionally, the ratio of the maximum local strain to the bulk average is 1.5, and the local strain-rate enhancement cannot explain the increased rate sensitivity of B 4 C/Al under dynamic loading. Therefore, the rate-dependent deformation heterogeneity dominates the strain-rate hardening of B 4 C/Al. Postmortem analyses help correlate deformation features to particle- and grain-scale microstructures, yielding consistent results with mesoscale strain fields.

36 MATERIALS SCIENCE↗

Seismicity and fault aseismic deformation caused by fluid injection in decametric in-situ experiments

Seismicity induced by fluid perturbations became an important societal concern since felt earthquakes ( M w up to 6) occurred after anthropogenic activities. In order to mitigate the risks associated with undesired seismicity, as well as to be able to use the micro-seismicity as a probe for in-depth investigation of fluid-driven processes, it is of crucial importance to understand the links between seismicity, fluid pressure and flow. We have developed a series of in-situ, decameter-scale experiments of fault zone reactivation by controlled fluid injection, in order to improve the near-source geophysical and hydromechanical observations. The deployed geophysical monitoring close to the injection allows one to cover the full frequency range of the fault responses from the static deformation to the very high-frequency seismic emissions (up to 4 kHz). Here, we focus on the microseismicity ( M w ~ –4 to –3) recorded during two fluid injection experiments in low-permeable shale and highly-fractured limestone formations. In both experiments, the spatio-temporal distribution of the seismic events, the energy balance, and the seismic velocity changes of the fractured medium show that most of the deformation does not actually emit seismic signals. The induced deformation is mainly aseismic. Based on these high-resolution multiparametric observations in the near-field, we therefore proposed a new model for injection-induced seismicity: the seismicity is not directly induced by the increasing fluid pressure, but it is rather triggered by the stress perturbations transferred from the aseismic motion caused by the injection.

58 GEOSCIENCES↗

Deformation and texture development in CaIrO[subscript 3] post-perovskite

At near ambient conditions, CaIrO{sub 3} is isostructural with the high-pressure polymorph MgSiO{sub 3} 'post-perovskite' (pPv). MgSiO{sub 3} pPv is thought to be a major phase in the earth's lowermost mantle. CaIrO{sub 3} can thus serve as an analog for studying deformation of the pPv phase under conditions achievable with a multi-anvil deformation apparatus. Here we study the rheologic behavior of CaIrO{sub 3} pPv at a variety of pressure and temperature conditions from 2 GPa to 6 GPa and 300 K to 1300 K and various strain rates. Sintered, polycrystalline CaIrO{sub 3} pPv, cylindrical in shape, was deformed in the D-DIA multi-anvil press in several shortening cycles up to 20% axial strain at each temperature and pressure. Shortening cycles were followed by lengthening back to 0% strain. Quantitative texture information was obtained using in-situ synchrotron X-ray diffraction and the Rietveld method to analyze images. In all cases we find that (010) lattice planes align perpendicular to the compression direction upon shortening, and that there is little change in texture with temperature or pressure. This texture pattern is consistent with slip on (010)[100]. The texture observed here is different from that produced in room temperature diamond anvil cell (DAC) experiments on MgGeO{sub 3} and MgSiO{sub 3} pPv which both display textures of (100) and {l_brace}110{r_brace} lattice planes at high angles to the compression direction. This implies that CaIrO{sub 3} pPv may not be a good analog for the plastic behavior of MgSiO{sub 3} pPv.

58 GEOSCIENCES↗

Evaluation of On-Board kV Cone Beam Computed Tomography–Based Dose Calculation With Deformable Image Registration Using Hounsfield Unit Modifications

Purpose: The purpose of this study was to estimate the accuracy of the dose calculation of On-Board Imager (Varian, Palo Alto, CA) cone beam computed tomography (CBCT) with deformable image registration (DIR), using the multilevel-threshold (MLT) algorithm and histogram matching (HM) algorithm in pelvic radiation therapy. Methods and Materials: One pelvis phantom and 10 patients with prostate cancer treated with intensity modulated radiation therapy were studied. To minimize the effect of organ deformation and different Hounsfield unit values between planning CT (PCT) and CBCT, we modified CBCT (mCBCT) with DIR by using the MLT (mCBCT{sub MLT}) and HM (mCBCT{sub HM}) algorithms. To evaluate the accuracy of the dose calculation, we compared dose differences in dosimetric parameters (mean dose [D{sub mean}], minimum dose [D{sub min}], and maximum dose [D{sub max}]) for planning target volume, rectum, and bladder between PCT (reference) and CBCTs or mCBCTs. Furthermore, we investigated the effect of organ deformation compared with DIR and rigid registration (RR). We determined whether dose differences between PCT and mCBCTs were significantly lower than in CBCT by using Student t test. Results: For patients, the average dose differences in all dosimetric parameters of CBCT with DIR were smaller than those of CBCT with RR (eg, rectum; 0.54% for DIR vs 1.24% for RR). For the mCBCTs with DIR, the average dose differences in all dosimetric parameters were less than 1.0%. Conclusions: We evaluated the accuracy of the dose calculation in CBCT, mCBCT{sub MLT}, and mCBCT{sub HM} with DIR for 10 patients. The results showed that dose differences in D{sub mean}, D{sub min}, and D{sub max} in mCBCTs were within 1%, which were significantly better than those in CBCT, especially for the rectum (P<.05). Our results indicate that the mCBCT{sub MLT} and mCBCT{sub HM} can be useful for improving the dose calculation for adaptive radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Near Real-Time Assessment of Anatomic and Dosimetric Variations for Head and Neck Radiation Therapy via Graphics Processing Unit–based Dose Deformation Framework

Purpose: The purpose of this study was to systematically monitor anatomic variations and their dosimetric consequences during intensity modulated radiation therapy (IMRT) for head and neck (H&N) cancer by using a graphics processing unit (GPU)-based deformable image registration (DIR) framework. Methods and Materials: Eleven IMRT H&N patients undergoing IMRT with daily megavoltage computed tomography (CT) and weekly kilovoltage CT (kVCT) scans were included in this analysis. Pretreatment kVCTs were automatically registered with their corresponding planning CTs through a GPU-based DIR framework. The deformation of each contoured structure in the H&N region was computed to account for nonrigid change in the patient setup. The Jacobian determinant of the planning target volumes and the surrounding critical structures were used to quantify anatomical volume changes. The actual delivered dose was calculated accounting for the organ deformation. The dose distribution uncertainties due to registration errors were estimated using a landmark-based gamma evaluation. Results: Dramatic interfractional anatomic changes were observed. During the treatment course of 6 to 7 weeks, the parotid gland volumes changed up to 34.7%, and the center-of-mass displacement of the 2 parotid glands varied in the range of 0.9 to 8.8 mm. For the primary treatment volume, the cumulative minimum and mean and equivalent uniform doses assessed by the weekly kVCTs were lower than the planned doses by up to 14.9% (P=.14), 2% (P=.39), and 7.3% (P=.05), respectively. The cumulative mean doses were significantly higher than the planned dose for the left parotid (P=.03) and right parotid glands (P=.006). The computation including DIR and dose accumulation was ultrafast (∼45 seconds) with registration accuracy at the subvoxel level. Conclusions: A systematic analysis of anatomic variations in the H&N region and their dosimetric consequences is critical in improving treatment efficacy. Nearly real-time assessment of anatomic and dosimetric variations is feasible using the GPU-based DIR framework. Clinical implementation of this technology may enable timely plan adaptation and improved outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A study on the surface severe plastic deformation behavior of a Zr-based bulk metallic glass (BMG)

A surface treatment process, which can generate the severe plastic deformation in the near-surface layer of crystalline materials, is successfully applied on the Zr{sub 50}Cu{sub 40}Al{sub 10} bulk metallic glass (BMG). The experiment is implemented using 20 WC/Co balls with a velocity of about 5 m/s to bombard the surface of the samples in a purified argon atmosphere. The plastic-flow deformation in the unconstrained sample edge was observed, which exhibits the good intrinsic ductility of this material under the experimental condition. In the sub-surface layer, the bombardment-induced shear-band operations generate the extrusion and intrusion marks on the side face. Differential scanning calorimetry (DSC) shows that the free volumes of the deformed BMG have increased, and possible crystallization may occur during the process. X-ray diffraction (XRD) and synchrotron high-energy X-ray diffraction techniques were used to inspect the possible crystal phase. A nanoindentation test shows that on the side surface, the hardness increases and, then, decreases with the distance from the processed surface. Four-point-bending-fatigue behavior has been studied and related to the modified surface structure and the compressive residual stress introduced by the surface treatment.

43 PARTICLE ACCELERATORS↗

Shape Determination for Deformed Electromagnetic Cavities

The measured physical parameters of a superconducting cavity differ from those of the designed ideal cavity. This is due to shape deviations caused by both loose machine tolerances during fabrication and by the tuning process for the accelerating mode. We present a shape determination algorithm to solve for the unknown deviations from the ideal cavity using experimentally measured cavity data. The objective is to match the results of the deformed cavity model to experimental data through least-squares minimization. The inversion variables are unknown shape deformation parameters that describe perturbations of the ideal cavity. The constraint is the Maxwell eigenvalue problem. We solve the nonlinear optimization problem using a line-search based reduced space Gauss-Newton method where we compute shape sensitivities with a discrete adjoint approach. We present two shape determination examples, one from synthetic and the other from experimental data. The results demonstrate that the proposed algorithm is very effective in determining the deformed cavity shape.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An adjoint method for a high-order discretization of deforming domain conservation laws for optimization of flow problems

We report the fully discrete adjoint equations and the corresponding adjoint method are derived for a globally high-order accurate discretization of conservation laws on parametrized, deforming domains. The conservation law on the deforming domain is transformed into one on a fixed reference domain by the introduction of a time-dependent mapping that encapsulates the domain deformation and parametrization, resulting in an Arbitrary Lagrangian–Eulerian form of the governing equations. A high-order discontinuous Galerkin method is used to discretize the transformed equation in space and a high-order diagonally implicit Runge–Kutta scheme is used for the temporal discretization. Quantities of interest that take the form of space–time integrals are discretized in a solver-consistent manner. The corresponding fully discrete adjoint method is used to compute exact gradients of quantities of interest along the manifold of solutions of the fully discrete conservation law. These quantities of interest and their gradients are used in the context of gradient-based PDE-constrained optimization. The adjoint method is used to solve two optimal shape and control problems governed by the isentropic, compressible Navier–Stokes equations. The first optimization problem seeks the energetically optimal trajectory of a 2D airfoil given a required initial and final spatial position. The optimization solver, driven by gradients computed via the adjoint method, reduced the total energy required to complete the specified mission nearly an order of magnitude. The second optimization problem seeks the energetically optimal flapping motion and time-morphed geometry of a 2D airfoil given an equality constraint on the x-directed impulse generated on the airfoil. The optimization solver satisfied the impulse constraint to greater than 8 digits of accuracy and reduced the required energy between a factor of 2 and 10, depending on the value of the impulse constraint, as compared to the nominal configuration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A high-order, localized-artificial-diffusivity method for Eulerian simulation of multi-material elastic-plastic deformation with strain hardening

A high-order method for Eulerian simulation of material undergoing large elastic–plastic deformation is developed. Thermodynamically consistent hyperelastic constitutive relations are assumed, facilitating the treatment of solids, liquids, and gases in a unified manner. Here, the method enables the simulation of multi-material interactions using a diffuse interface approach. Numerical capturing of material interfaces, shock waves, contact surfaces, and elastic-plastic strain discontinuities using high-order compact-difference schemes is assisted by Localized Artificial Diffusivity (LAD). In the new setting involving elastic–plastic deformation, the previously established terms for the artificial properties are verified to effectively regularize normal shocks. Additional LAD terms are introduced to the elastic and plastic kinematic equations to regularize shear shocks and other strain discontinuities, improving solution stability. Other important features of the method that improve robustness include the numerical treatment of compatibility terms in the kinematic equations, and the treatment of rotation. Particular emphasis is focused toward new advancements of the methods for plastic-deformation integration and the associated strain hardening of the material, including rate-dependent plasticity. The method is demonstrated on a variety of test problems, including 1-D impacts, a variant of the Shu-Osher problem, a Taylor impact, and a Richtmyer-Meshkov instability between two elastic–plastic solids with strain hardening.

42 ENGINEERING↗

Mass transport in a highly immiscible alloy on extended shear deformation

Forced mixing to a single phase or supersaturated solid solution (SSS) and its prerequisite microstructure evolution in immiscible systems has been a focus of research for both fundamental science and a variety of applications. Controlling the formation of SSS by shear deformation assisted processing could enable a material design beyond conventional equilibrium microstructure in immiscible systems. Here, a highly immiscible (mixing enthalpy of ~ 20 kJ·mol -1 ) Cu-50 at. % Cr binary alloy was employed to investigate the microstructure evolution and localized tendencies of SSS during severe shear deformation. The present results demonstrate distinctive microstructure refinement process in each phase and how they lead to localized SSS as a function of shear strain. Preferential dynamic recrystallization occurs in the softer Cu phase due to strain localization, leading to substantial grain refinement. The refinement of Cr phase in the top-most layer, however, is enabled by the progressive evolution of grain lamination, splitting, and fragmentation as a function of shear strain. The eventual SSS is found to be strongly dependent on the local environments that affect the dislocation activity, including the level of microstructure refinement, the interfacial orientation relationship, hardness difference, and supposed stability of oxidation. Ab initio simulations comfirm that it is more favorable to oxidize Cr than Cu at incoherent Cu/Cr interfaces which then limits the mass transport on an incoherent boundary. Our results shed light on the underpinning mechanism for non-equilibrium mass transport in immiscible systems upon severe deformation that can be applicable to a variety of processing techniques aimed at producing immiscible alloys with superior mechanical properties.

36 MATERIALS SCIENCE↗

Analysis of structure and deformation behavior of AISI 316L tensile specimens from the second operational target module at the Spallation Neutron Source

In an earlier publication, tensile testing was performed on specimens removed from the first two operational targets of the Spallation Neutron Source (SNS). There were several anomalous features in the results. First, some specimens had very large elongations (up to 57%) while others had significantly smaller values. Second, there was a larger than the usual amount of data scatter in the elongation results. Third, the stress-strain diagrams of nominally similar specimens spanned a wide range of behavior ranging from expected irradiation-induced hardening to varying levels of force drop after yield point and indirect signs of "traveling deformation wave" behavior associated with strain-induced martensite formation. To investigate the cause(s) of such variable tensile behavior, several specimens from Target 2, spanning the range of observed tensile behavior, were chosen for detailed microstructural examination using electron backscattering analysis (EBSD). It was also shown that the steel employed in the construction of the target contained an unexpected bimodal grain size distribution, containing very large out-of-specification grains surrounded by necklaces of grains of within-specification sizes. The large grains were frequently comparable to the width of the gauge section of the tensile specimen. Moreover, the propensity to form martensite during deformation was shown to be accelerated by radiation but also to be very sensitive to the relative orientation of the grains with respect to the tensile axis. Specimens having large grains in the gauge that were most favorably oriented for production of martensite strongly exhibited the traveling deformation wave phenomenon, while those specimens with less favorably oriented grains had lesser or no degree of the wave effect, thereby accounting for the larger than expected data scatter.

316L↗

Deformation localisation in ion-irradiated Fe and Fe10Cr

Determining the mechanisms for irradiation-induced ductility loss is crucial for the design of reactor structural components. Here, the deformation characteristics around nanoindents in Fe and Fe10Cr irradiated with Fe ions to ~1 displacement-per-atom at 313 K are non-destructively studied. Slip steps surrounding the nanoindents indicate that deformation is localised in the irradiated materials. Lattice rotation and strain fields near the indent site show over 87% confinement of plasticity in the irradiated material. Cr has little effect on the irradiation-induced changes in pile-up topography and deformation fields, suggesting it has limited impact on retaining strain hardening capacity and reducing irradiation-induced embrittlement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A spatially-resolved model of neutron-irradiated tungsten coupling stochastic cluster dynamics and finite deformation plasticity

Structural materials used in nuclear reactors face severe degradation in mechanical properties, such as hardening and embrittlement. At the microscopic scale, this occurs due to creation and accumulation of irradiation-induced defects and their interaction with system dislocations. Although techniques exist which can model evolution of irradiation defects, for instance kinetic transport theory-based models, their interaction with mechanical deformation of the bulk material has not been investigated extensively. In this work, we demonstrate a novel spatially-resolved multiscale coupling between microscopic irradiation defect evolution, modeled using Stochastic Cluster Dynamics (SCD) and macroscopic mechanical deformation modeled using a finite-deformation plasticity model. SCD is used to determine the statistically averaged defect cluster spacing, dependent on operating conditions such as irradiation dose and temperature. This acts as an initial condition that governs the critical resolved shear stress of dislocation glide in the macroscopic plasticity model. This framework is used to predict mechanical behavior in post-mortem test of irradiated Tungsten samples, which has found its importance as structural material used in nuclear reactors. The results obtained using the coupled approach are in good agreement with experimental data of uniaxial tension tests. The model is able to capture the effect of temperature and irradiation dose on the material hardening. Two methods are proposed to estimate hardness – using Tabor's Law relating uniaxial yield stress to hardness and from flat-punch simulations. The results are in reasonable agreement with hardness data from micro-indentation experiments of irradiated Tungsten samples. Finally, the model is also able to reveal microstructural details such as spatial variation in defect density and local stress.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗