Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

A Novel, Low-Cost, Reduced-Sensor Approach for Providing Smart Renote Monitoring and Diagnostics for Packaged Air Conditioners and Heat Pumps

This report describes conceptually an approach to providing automated remote performance and conditioning monitoring and fault detection for air conditioners and heat pumps that shows great promise to reduce the capital and installation costs of such systems from over $1000 per unit to $200 to $400 per unit. The approach relies on non-intrusive electric load monitoring (NIELM) to enable separation of the power use signals of compressors and fans in the air conditioner or heat pump. Then combining information on the power uses and one or two air temperature measurements, changes in energy efficiency and occurrence of major faults would be detected. By decreasing the number of sensors used from between ten and twenty in current diagnostic monitoring systems to three for the envisaged system, the capital cost of the monitoring system hardware and the cost of labor for installation would be decreased significantly. After describing the problem being addressed and the concept for performance monitoring and fault detection in more detail, the report identifies specific conditions and faults that the proposed method would detect, discusses specific needs for successful use of the NIELM approach, and identifies the major elements in the path from concept to a commercialized monitoring and diagnostic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heavy Ion Fusion Science Virtual National Laboratory 4th Quarter 2009 Milestone Report: Measure and simulate target temperature and dynamic response in optimized NDCX-I configurations with initial diagnostics suite

This milestone has been met. The effort contains two main components: (1) Experimental results of warm dense matter target experiments on optimized NDCX-I configurations that include measurements of target temperature and transient target behavior. (2) A theoretical model of the target response to beam heating that includes an equilibrium heating model of the target foil and a model for droplet formation in the target for comparison with experimental results. The experiments on ion-beam target heating use a 300-350-keV K{sup +} pulsed beam from the Neutralized Compression Drift Experiment (NDCX-I) accelerator at LBNL. The NDCX-I accelerator delivers an uncompressed pulse beam of several microseconds with a typical power density of >100 kW/cm{sup 2} over a final focus spot size of about 1 mm. An induction bunching module the NDCX-I compresses a portion of the beam pulse to reach a much higher power density over 2 nanoseconds. Under these conditions the free-standing foil targets are rapidly heated to temperatures to over 4000 K. We model the target thermal dynamics using the equation of heat conduction for the temperature T(x,t) as a function of time (t) and spatial dimension along the beam direction (x). The competing cooling processes release energy from the surface of the foil due to evaporation, radiation, and thermionic (Richardson) emission. A description of the experimental configuration of the target chamber and results from initial beam-target experiments are reported in our FY08 4th Quarter and FY09 2nd Quarter Milestone Reports. The WDM target diagnostics include a high-speed multichannel optical pyrometer, optical streak camera, VISAR, and high-speed gated cameras. The fast optical pyrometer is a unique and significant new diagnostic which provides valuable information on the temperature evolution of the heated target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic-Noise Diagnostics

The influence of the ambient temperature and the thickness of the paint coating on the magnetic-noise parameters is investigated, in the diagnostics of steel structures. It is shown that nondestructive magnetic-noise diagnostics may be used to monitor the state of load-bearing structural elements in situ at any temperature, in extreme conditions.

42 ENGINEERING↗

On the processes generating latitudinal richness gradients: identifying diagnostic patterns and predictions

Many processes have been put forward to explain the latitudinal gradient in species richness. Here, we use a simulation model to examine four of the most common hypotheses and identify patterns that might be diagnostic of those four hypotheses. The hypotheses examined include (1) tropical niche conservatism, or the idea that the tropics are more diverse because a tropical clade origin has allowed more time for diversification in the tropics and has resulted in few species adapted to extra-tropical climates. (2) The productivity, or energetic constraints, hypothesis suggests that species richness is limited by the amount of biologically available energy in a region. (3) The tropical stability hypothesis argues that major climatic fluctuations and glacial cycles in extratropical regions have led to greater extinction rates and less opportunity for specialization relative to the tropics. (4) Finally, the speciation rates hypothesis suggests that the latitudinal richness gradient arises from a parallel gradient in rates of speciation. We found that tropical niche conservatism can be distinguished from the other three scenarios by phylogenies which are more balanced than expected, no relationship between mean root distance and richness across regions, and a homogeneous rate of speciation across clades and through time. The energy gradient, speciation gradient, and disturbance gradient scenarios all exhibited phylogenies which were more imbalanced than expected, showed a negative relationship between mean root distance and richness, and diversity-dependence of speciation rate estimates through time. Using Bayesian Analysis of Macroevolutionary Mixtures on the simulated phylogenies, we found that the relationship between speciation rates and latitude could distinguish among these three scenarios. We emphasize the importance of considering multiple hypotheses and focusing on diagnostic predictions instead of predictions that are consistent with more than one hypothesis.

biodiversity↗

Image-Guided Intraoperative Assessment of Surgical Margins in Oral Cavity Squamous Cell Cancer: A Diagnostic Test Accuracy Review

The assessment of resection margins during surgery of oral cavity squamous cell cancer (OCSCC) dramatically impacts the prognosis of the patient as well as the need for adjuvant treatment in the future. Currently there is an unmet need to improve OCSCC surgical margins which appear to be involved in around 45% cases. Intraoperative imaging techniques, magnetic resonance imaging (MRI) and intraoral ultrasound (ioUS), have emerged as promising tools in guiding surgical resection, although the number of studies available on this subject is still low. The aim of this diagnostic test accuracy (DTA) review is to investigate the accuracy of intraoperative imaging in the assessment of OCSCC margins. By using the Cochrane-supported platform Review Manager version 5.4, a systematic search was performed on the online databases MEDLINE-EMBASE-CENTRAL using the keywords “oral cavity cancer, squamous cell carcinoma, tongue cancer, surgical margins, magnetic resonance imaging, intraoperative, intra-oral ultrasound”. Ten papers were identified for full-text analysis. The negative predictive value (cutoff < 5 mm) for ioUS ranged from 0.55 to 0.91, that of MRI ranged from 0.5 to 0.91; accuracy analysis performed on four selected studies showed a sensitivity ranging from 0.07 to 0.75 and specificity ranging from 0.81 to 1. Image guidance allowed for a mean improvement in free margin resection of 35%. IoUS shows comparable accuracy to that of ex vivo MRI for the assessment of close and involved surgical margins, and should be preferred as the more affordable and reproducible technique. Both techniques showed higher diagnostic yield if applied to early OCSCC (T1–T2 stages), and when histology is favorable.

60 APPLIED LIFE SCIENCES↗

Chimera Spectrum Diagnostics for Peptides Using Two-Dimensional Partial Covariance Mass Spectrometry

The rate of successful identification of peptide sequences by tandem mass spectrometry (MS/MS) is adversely affected by the common occurrence of co-isolation and co-fragmentation of two or more isobaric or isomeric parent ions. This results in so-called `chimera spectra’, which feature peaks of the fragment ions from more than a single precursor ion. The totality of the fragment ion peaks in chimera spectra cannot be assigned to a single peptide sequence, which contradicts a fundamental assumption of the standard automated MS/MS spectra analysis tools, such as protein database search engines. This calls for a diagnostic method able to identify chimera spectra to single out the cases where this assumption is not valid. Here, we demonstrate that, within the recently developed two-dimensional partial covariance mass spectrometry (2D-PC-MS), it is possible to reliably identify chimera spectra directly from the two-dimensional fragment ion spectrum, irrespective of whether the co-isolated peptide ions are isobaric up to a finite mass accuracy or isomeric. We introduce ‘3-57 chimera tag’ technique for chimera spectrum diagnostics based on 2D-PC-MS and perform numerical simulations to examine its efficiency. We experimentally demonstrate the detection of a mixture of two isomeric parent ions, even under conditions when one isomeric peptide is at one five-hundredth of the molar concentration of the second isomer.

47 OTHER INSTRUMENTATION↗

H α AS A LUMINOSITY CLASS DIAGNOSTIC FOR K- AND M-TYPE STARS

We have identified the H α absorption feature as a new spectroscopic diagnostic of luminosity class in K- and M-type stars. From high-resolution spectra of 19 stars with well-determined physical properties (including effective temperatures and stellar radii), we measured equivalent widths for H α and the Ca ii triplet and examined their dependence on both luminosity class and stellar radius. H α shows a strong relation with both luminosity class and radius that extends down to late M spectral types. This behavior in H α has been predicted as a result of the density-dependent overpopulation of the metastable 2s level in hydrogen, an effect that should become dominant for Balmer line formation in non-LTE conditions. We conclude that this new metallicity-insensitive diagnostic of luminosity class in cool stars could serve as an effective means of discerning between populations such as Milky Way giants and supergiant members of background galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Validating the C i 5052.17 Å/Mg ii 4481 Å Equivalent Width Ratio as a Diagnostic for F-type Lambda Boo Stars

The Lambda Boo-type stars are chemically peculiar stars with deficiencies of iron-peak elements but near-solar C, N, O, and S abundances. Since the prototype Lambda Boötis was first reported as peculiar, this group has been expanded from a small group of early A-type stars to a larger group of late B to early F-type dwarfs. Although a detailed abundance analysis that supports the Lambda Boo-like abundance pattern is the definitive confirmation of this Lambda Boo characteristic, the rapid rotation of many Lambda Boo stars generally limits how much detail can be derived from an abundance analysis. Traditionally, Lambda Boo candidates have been classified by visually examining the difference between their spectra and spectra of standard stars. Therefore, some ambiguity remains especially for mild or borderline Lambda Boo stars. This is the third paper in a series that establishes a straightforward yet reliable way to identify Lambda Boo-type stars. In previous papers, we identified line equivalent width (EW) ratios in the ultraviolet and visible regions that can distinguish Lambda Boo stars from other metal-weak stars. In this paper, we apply the visible line EW ratio diagnostic to 25 Lambda Boo candidates and carry out a detailed abundance analysis of HD 81290, an F2 star with a C i/Mg ii EW ratio in the range expected for Lambda Boo-type stars. Our elemental abundance analysis results confirm HD 81290's Lambda Boo membership and demonstrate the utility of our EW ratio as a diagnostic for cooler F-type Lambda Boo stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Diagnostics of coronal heating in active-region loops

Understanding coronal heating remains a central problem in solar physics. Many mechanisms have been proposed to explain how energy is transferred to and deposited in the corona. We summarize past observational studies that attempted to identify the heating mechanism and point out the difficulties in reproducing the observations of the solar corona from the heating models. The aim of this paper is to study whether the observed extreme ultraviolet (EUV) emission in individual coronal loops in solar active regions can provide constraints on the volumetric heating function, and to develop a diagnostic for the heating function for a subset of loops that are found close to static thermal equilibrium. We reconstruct the coronal magnetic field from Solar Dynamics Observatory/HMI data using a nonlinear force-free magnetic field model. We model selected loops using a one-dimensional stationary model, with a heating rate dependent locally on the magnetic field strength along the loop, and we calculate the emission from these loops in various EUV wavelengths for different heating rates. We present a method to measure a power index β defining the dependence of the volumetric heating rate E{sub H} on the magnetic field, E{sub H}∝B{sup β}, and controlling also the shape of the heating function: concentrated near the loop top, uniform and concentrated near the footpoints. The diagnostic is based on the dependence of the electron density on the index β. This method is free from the assumptions of the loop filling factor but requires spectroscopic measurements of the density-sensitive lines. The range of applicability for loops of different length and heating distributions is discussed, and the steps to solving the coronal heating problem are outlined.

79 ASTRONOMY AND ASTROPHYSICS↗

CHEMICAL EVOLUTION OF THE UNIVERSE AT 0.7 < z < 1.6 DERIVED FROM ABUNDANCE DIAGNOSTICS OF THE BROAD-LINE REGION OF QUASARS

We present an analysis of Mg ii λ 2798 and Fe ii UV emission lines for archival Sloan Digital Sky Survey (SDSS) quasars to explore the diagnostics of the magnesium-to-iron abundance ratio in a broad-line region cloud. Our sample consists of 17,432 quasars selected from the SDSS Data Release 7 with a redshift range of 0.72 < z < 1.63. A strong anticorrelation between the Mg ii equivalent width (EW) and the Eddington ratio is found, while only a weak positive correlation is found between the Fe ii EW and the Eddington ratio. To investigate the origin of these differing behaviors of Mg ii and Fe ii emission lines, we perform photoionization calculations using the Cloudy code, where constraints from recent reverberation mapping studies are considered. We find from calculations that (1) Mg ii and Fe ii emission lines are created at different regions in a photoionized cloud, and (2) their EW correlations with the Eddington ratio can be explained by just changing the cloud gas density. These results indicate that the Mg ii/Fe ii flux ratio, which has been used as a first-order proxy for the Mg/Fe abundance ratio in chemical evolution studies with quasar emission lines, depends largely on the cloud gas density. By correcting this density dependence, we propose new diagnostics of the Mg/Fe abundance ratio for a broad-line region cloud. In comparing the derived Mg/Fe abundance ratios with chemical evolution models, we suggest that α -enrichment by mass loss from metal-poor intermediate-mass stars occurred at z ∼ 2 or earlier.

79 ASTRONOMY AND ASTROPHYSICS↗

The Formation of IRIS Diagnostics. IX. The Formation of the C i 135.58 NM Line in the Solar Atmosphere

The C i 135.58 nm line is located in the wavelength range of NASA’s Interface Region Imaging Spectrograph ( IRIS ) small explorer mission. We study the formation and diagnostic potential of this line by means of non local-thermodynamic-equilibrium modeling, employing both 1D and 3D radiation-magnetohydrodynamic models. The C i/C ii ionization balance is strongly influenced by photoionization by Ly α emission. The emission in the C i 135.58 nm line is dominated by a recombination cascade and the line forming region is optically thick. The Doppler shift of the line correlates strongly with the vertical velocity in its line forming region, which is typically located at 1.5 Mm height. With IRIS , the C i 135.58 nm line is usually observed together with the O i 135.56 nm line, and from the Doppler shift of both lines, we obtain the velocity difference between the line forming regions of the two lines. From the ratio of the C i/O i line core intensity, we can determine the distance between the C i and the O i forming layers. Combined with the velocity difference, the velocity gradient at mid-chromospheric heights can be derived. The C i/O i total intensity line ratio is correlated with the inverse of the electron density in the mid-chromosphere. We conclude that the C i 135.58 nm line is an excellent probe of the middle chromosphere by itself, and together with the O i 135.56 nm line the two lines provide even more information, which complements other powerful chromospheric diagnostics of IRIS such as the Mg ii h and k lines and the C ii lines around 133.5 nm.

79 ASTRONOMY AND ASTROPHYSICS↗

Extremely Early Diagnostic Test for Prostate Cancer

This article reports the results of a blinded fiber diffraction study of skin samples taken from TRAMP mice and age-matched controls to determine whether changes noted in fiber diffraction studies of human skin were present in these TRAMP mice studies. These mice are bred to progress to Gleeson Type 3 to Type 5 prostate cancer. Small strips, 1 mm x 5 mm, cut from the mouse skin samples were loaded into cells in the same way as human samples and slightly stretched to remove the crimp. They remained fully hydrated throughout exposure to the synchrotron beam. The added change that was reported for prostate cancer in 2009 was obtained for all TRAMP mice samples, indicating that this change can be read as High Grade Cancer in human diagnostic tests. These changes were evident for all 3 and 7 week old TRAMP mice samples but not for any of the control samples. This indicates that the changes in the fibre diffraction patterns appear much earlier than in any other available prostate cancer diagnostic test, as none of these can verify the presence of prostate cancer in the TRAMP mice before 10 weeks of age. The fiber diffraction test is therefore the most accurate and earliest test for high grade prostate cancer.

59 BASIC BIOLOGICAL SCIENCES↗

Diagnostic development for parallel wave-number measurement of lower hybrid waves in EAST

An eight-channel magnetic probe diagnostic system has been designed and installed adjacent to the 4.6 GHz lower hybrid (LH) grill antenna in the low-field side of the EAST tokamak in order to study the n|| evolution of lower hybrid waves in the first pass from the launcher to the core plasma. The magnetic probes are separated by 6.6 mm, which allows measurement of the dominant parallel refractive index n|| up to n|| =5 for 4.6GHz LH waves. The magnetic probes are designed to be sensitive to the magnetic field component perpendicular to the background magnetic field with a slit on the casing that encloses the probe. The intermediate frequency (IF) stage, which consists of two mixing stages, down-coverts the frequency of the measured wave signals at 4.6 GHz to 20 MHz. A bench test demonstrates the phase stability of the magnetic probe diagnostic system. By evaluating the phase variation of the measured signals along the background magnetic field, the dominant n|| of the LH wave in the scrape-off layer (SOL) has been deduced during the 2019 experimental campaign. In the low density plasma, the measured dominant n|| of the lower hybrid waves is about 2.1, corresponding to the main peak 2.04 of the launched n|| spectrum. The n|| deduced by the least square linear fit method remains near this value in the low density plasma with a high spatial correlation magnitude of 0.9. With an eight-channel probe system a wave-number spectrum has also been deduced, which has a peak near to the measured dominant n||.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative comparisons of electron-scale turbulence measurements in NSTX via synthetic diagnostics for high-k scattering.

Two synthetic diagnostics are implemented for the high-k scattering system in NSTX [D. R. Smith, E. Mazzucato, W. Lee, H. K. Park, C. W. Domier, and N. C. Luhmann Jr., Rev. Sci. Instrum., 79, 123501 (2008)] allowing direct comparisons between synthetic and experimentally detected frequency and wavenumber spectra of electron-scale turbulence fluctuations. Synthetic diagnostics were formulated in real-space and in wavenumber space, and were deployed to realistic electron-scale simulations carried out with the GYRO code [J. Candy and R. E. Waltz, J. Comput. Phys. 186 (2003) 545]. A highly unstable ETG regime (electron temperature gradient mode) in a modest beta NSTX NBI-heated H-mode discharge was chosen for the analysis. Mapping the measured wavenumbers to field aligned coordinates showed that the high-k system is sensitive to fluctuations that are closer to the spectral peak in the density fluctuation wavenumber spectrum (streamers) than originally predicted. Analysis of synthetic spectra show that the frequency response of the detected fluctuations is dominated by Doppler shift and insensitive to the turbulence drive. The shape of the high-k density fluctuation wavenumber spectrum is sensitive to the ETG turbulence drive conditions, and can be reproduced in a sensitivity scan of the most pertinent turbulent drive terms in the simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A magnetic particle time-of-flight (MagPTOF) diagnostic for measurements of shock and compression-bang time at the NIF [National Ignition Facility]

A magnetic particle time-of-flight (MagPTOF) diagnostic has been designed to measure shock- and compression-bang time using DHe-fusion protons and DD-fusion neutrons, respectively, at the National Ignition Facility (NIF). This capability, in combination with shock-burn weighted areal density measurements, will significantly constrain the modeling of the implosion dynamics. This design is an upgrade to the existing particle time-of-flight (pTOF) diagnostic, which records bang times using DD or DT neutrons with an accuracy better than ±70 ps [H. G. Rinderknecht et al., Rev. Sci. Instrum. 83, 10D902 (2012)]. The inclusion of a deflecting magnet will increase DHe-proton signal-to-background by a factor of 1000, allowing for the first time simultaneous measurements of shock and compression-bang times in DHe-filled surrogate implosions at the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional AXUV-based radiated power density diagnostics on NSTX-U

A new set of radiated-power-density diagnostics for the National Spherical Torus Experiment Upgrade (NSTX-U) tokamak have been designed to measure the two-dimensional poloidal structure of the total photon emissivity profile in order to perform power balance, impurity transport, and magnetohydrodynamic studies. Multiple AXUV-diode based pinhole cameras will be installed in the same toroidal angle at various poloidal locations. The local emissivity will be obtained from several types of tomographic reconstructions. The layout and response expected for the new radially viewing poloidal arrays will be shown for different impurity concentrations to characterize the diagnostic sensitivity. The radiated power profile inverted from the array data will also be used for estimates of power losses during transitions from various divertor configurations in NSTX-U. The effect of in-out and top/bottom asymmetries in the core radiation from high-Z impurities will be addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Material injection alleviation and plasma diagnostic measurements during the RAM C-III flight.

The results of a material injection RF blackout alleviation experiment and of plasma diagnostic measurements using electrostatic probes and an S-band reflectometer in a 25,000 ft/sec reentry flight are presented. Significant alleviation of RF blackout is observed at altitudes of from 270,000 feet to 120,000 feet due to injection of water and Freon E-3 on VHF, S-band, C-band, and X-band frequencies. Electrostatic probe data, attenuation data, and S-band diagnostic data show consistent plasma results. The relative effectiveness of water and Freon E-3 is discussed.

Schroeder, L. C.↗