Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Dependence of Photosynthetic Capacity, Photosynthetic Pigment Allocation, and Carbon Storage on Nitrogen Levels in Foliage of Aspen Stands

The role of foliar nitrogen (N) in the seasonal dynamics and vertical canopy distribution of photosynthetic pigments, photosynthetic capacity, and carbon (C) storage was investigated in boreal broadleaved species. The study was conducted at two different aged stands (60 y and 15 y) in 1994 and 1996 in Saskatchewan, Canada as part of the Boreal Ecosystem-Atmosphere Study (BOREAS). Foliage in upper and lower strata was examined for aspen (Populus tremuloides Michx.) and its associated hazelnut shrub (Corylus americana Walt.). We determined that C accumulation, expressed as dry mass per unit leaf area (mg C cm (exp -2)), was linearly dependent on N content (approximately 0.3- 3.5 mg N cm (exp -2))(r (exp 2) = 0.93, n=383, P less than 0.001) when eleven foliage groups were defined according to species, site, and developmental stage. C assembly was greatest in the upper aspen strata of both sites (seasonal average, 40.1 plus or minus 0.6 mg C cm (exp -2)), intermediate in the lower aspen strata (32.7 plus or minus 0.6), and considerably lower, and similar, in the hazelnut shrub layers (23.7 plus or minus 0.6) and in expanding aspen leaves (23.8 plus or minus 0.5); the lowest C assembly per unit N occurred in the two youngest, emerging leaf groups (17.1 plus or minus 0.6). Other relationships among physiological and biochemical variables were typically non-linear and were confounded by inclusion of the three groups of young (i.e., emerging or expanding) leaves, unless these were separately identified. Net C uptake, measured as photosynthetic capacity (A (sub max), micromole CO2 m (exp -2) s (exp -1)), was greater in aspen throughout the season, and optimal in mid-summer at a C:N ratio of approximately 18 (approximately 2.3 %N). When young leaves were excluded and logarithms of both variables were used, A (sub max) was approximately linearly dependent on N (mg N cm (exp-2) (r (exp 2) = 0.85, n= 193, P less than 0.001), attributed to incorporation of N into photosynthetic complexes and enzymes. In mature leaves, differences in pigment content vs. N among canopy strata were accentuated when N was expressed per unit leaf area (Mg cm (exp -2)) . However, the simplest log-linear relationship between a pigment variable and N was obtained for a ratio describing the relative allocation of photosynthetic pigment to Chl a (Chl a/[Chl b + carotenoids], microgram cm (exp -2)/ microgram cm-2) vs. %N (r (exp 2) = 0.90, n=343, P less than 0.001). Attainment of comparable A (sub max) Chl a content and relative Chl a allocation per unit N (mg cm (exp -2)) was achieved at different foliar N levels per canopy group: the lowest N requirement was for hazelnut leaves in the lowest, shaded stratum at the older, closed canopy site; the highest N requirement was in aspen leaves of the upper-most stratum at the younger, more open canopy site. These results highlight the differences in physiological responses between young and fully expanded leaves and show that sustaining those foliar constituents and processes important to C balance may require higher foliar N levels in leaves of establishing vs. mature aspen stands. There may be implications for remote-sensing assessments made for carbon balance in springtime, or over a landscape mosaic comprised of different aged stands.

Middleton, Elizabeth M.↗

Coordinative Voltage Control Strategy with Multiple Resources for Distribution Systems of High PV Penetration

This paper presents an optimal voltage control methodology with coordination among different voltage-regulating resources, including controllable loads, distributed energy resources such as energy storage and photovoltaics (PV), and utility voltage-regulating devices such as voltage regulators and capacitors. The proposed methodology could effectively tackle the overvoltage and voltage regulation device distortion problems brought by high penetrations of PV to improve grid operation reliability. A voltage-load sensitivity matrix and voltage-regulator sensitivity matrix are used to deploy the resources along the feeder to achieve the control objectives. Mixed-integer nonlinear programming is used to solve the formulated optimization control problem. The methodology has been tested on the IEEE 123-feeder test system, and the results demonstrate that the proposed approach could improve the voltage profile of distribution system operation.

14 SOLAR ENERGY↗

Bending Magnet Synchrotron Radiation Imaging with Large Orbital Collection Angles

Synchrotron radiation (SR) from bending magnets, wigglers, and undulators is now extensively produced for users at storage ring based light sources, with unique properties in terms of average brightness and stability. Here, we present a profound study of bending magnet SR intensity distribution in the image plane of a focusing optical system. Measurements of this intensity distribution at the MAX-IV low emittance storage ring are compared to theoretical predictions, and found to be in excellent agreement. This work shows upon the possibility of performing high resolution emittance diagnostics with visible or near-visible SR on upcoming low-emittance storage ring based light sources. As a byproduct of our study, we derive a closed analytical expression for the intensity distribution from a zero-emittance beam, in the limiting case of wide orbital collection angles. This expression finally allows us to demonstrate the meeting between classical electrodynamics applied to SR emission and focusing, and the Landau and Lifshitz prediction of radiation intensity distribution nearby a caustic.

36 MATERIALS SCIENCE↗

Buildings-to-Grid Technical Opportunities: From the Information and Communications Technology Perspective

Information and communications technology (ICT) has enabled the integration of computer and audio-visual networks, leading to unprecedented exchange of data between various users and entities. By providing the infrastructure to coordinate millions of distributed assets within and across buildings, including variable loads, distributed energy resources, and energy-storage, ICT has the potential to lead to a similar convergence across building and grid domains. This paper illustrates obstacles to a broad application of ICT, lists steps to resolve these barriers, and explains how applying ICT to the building and grid domains, as well as the interface between those two domains, could provide new value to stakeholders by facilitating an exchange of services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power-to-Gas System Valuation. Final Report

To provide a framework for evaluating the technical and financial benefits of a power-to-gas (P2G) system deployed in the Holyoke Gas and Electric (HG&E) system, Pacific Northwest National Laboratory modified its energy storage valuation tools to run a one-year simulation of P2G operations. The simulation was used to evaluate the benefits of P2G for multiple grid and industrial applications over the economic life of the unit, or units, depending on the asset configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Triboelectric generators and sensors

A triboelectric power system includes a triboelectric generator, a rechargeable energy storage unit and a power management circuit. The rechargeable energy storage unit is associated to the triboelectric generator. The power management circuit is configured to receive an input current from the triboelectric generator and to deliver an output current corresponding to the input current to the rechargeable battery so that the output current has a current direction and a voltage that will recharge the rechargeable battery.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of Large Scale Transmission Limitations on Renewable Energy Load Matching for Western U.S.: Preprint

Based on the available geographically dispersed data for the Western U.S. (excluding Alaska), we analyze to what extent the geographic diversity of these resources can offset their variability. Without energy storage and assuming unlimited energy flows between regions, wind and PV can meet up to 80% of loads in Western U.S. while less than 10% of the generated power is curtailed. Limiting hourlyenergy flows by the aggregated transmission line carrying capacities decreases the fraction of the load that can be met with wind and PV generation to approximately 70%.

14 SOLAR ENERGY↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

Dynamic Frequency Regulation Improvement in Hydropower-Hybrid System using Variational Mode Decomposition

Providing frequency response, especially fast frequency response such as Red D in the Pennsylvania-New Jersey-Maryland Interconnection (PJM) market, is challenging for many generation plants to deliver on their own. If they have adequate flexibility, hydropower plants are typically able to provide slower regulation support (e.g., Reg A in PJM), but do not respond fast enough to provide Reg D. The ability to provide Reg D would improve their revenue because this service is typically more valuable. This work presents a control approach to use hydropower, battery, and ultracapacitor systems to provide fast regulation in a way that uses the response contribution of each asset. In particular, the proposed control architecture applies a variational mode decomposition (VMD) technique on the incoming Reg D signal to extract multiple dynamic-regulation components with non-overlapping frequencies. With the response-speed dependent alignment, these regulation components are fed to the hydrogenator and hybrid energy storage system (HESS). The paper evaluates the proposed approach on a direct-current (DC)-coupled active system by computing several performance measures and analyzing sensitivity based on HESS component proportional capacities. The results reveal that the proposed VMD-based signal conditioning performs well and that optimizing the sizing of the battery and ultracapacitor components further enhances performance.

13 HYDRO ENERGY↗

Transitioning to Hybrid Power Plants

Hybrid power plants are power generation systems that combine two or more types of electricity generation or storage, creating systems where the optimal dispatch provides more benefits that the sum of the individual components can. These plants exemplify the interconnected challenges of grid modernization. On one hand, rapid increase in deployment and enhanced controllability of renewable energy assets is needed to meet clean energy targets, but on the other, increasing electrification makes it more difficult to manage load and growth in the number of endpoints and stakeholders involved with hybrid plants complicates asset management and cybersecurity. This talk will cover trends in hybrid power plant technologies and deployments, identify future prospects for hybrid systems, and discuss the challenges and research opportunities that exist to transition from the traditional power grids of today to smart, distributed, hybrid power grids we may see in the next few decades.

14 SOLAR ENERGY↗

Investigating Net-Zero Carbon Microgrids for DOE’s National Laboratory Facilities: A Case Study for Idaho National Laboratory

The concept of net-zero carbon microgrids (NZMs) has received significant interest in recent years considering its promises to provide both energy resilience and carbon reduction. This paper investigates the practical constraints of NZM deployment in a government facility, exploring various cases revolving around the objectives of cost, emission, and energy resilience. The technoeconomic results for one of the Idaho National Laboratory (INL) facilities are discussed to identify a practical and economic approach to achieve the net-zero target considering both present and future scenarios. The study shows the carbon reduction, resilience, and economic success of net-zero initiatives are tied directly to the energy portfolio of its electricity provider. The NZMs typically required a hybrid mix of renewable generation and storage assets to maximize onsite clean generation and to provide reliable power during grid outages. Besides supporting the ongoing net-zero effort at INL, this work also provides a framework that can be directly used in other facilities aspiring to become a net zero in the future.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Coordinative Voltage Control Strategy with Multiple Resources for Distribution Systems of High PV Penetration: Preprint

This paper presents an optimal voltage control methodology with coordination among different voltage-regulating resources, including controllable loads, distributed energy resources such as energy storage and photovoltaics (PV), and utility voltage-regulating devices such as voltage regulators and capacitors. The proposed methodology could effectively tackle the overvoltage and voltage regulation device distortion problems brought by high penetrations of PV to improve grid operation reliability. A voltage-load sensitivity matrix and voltage-regulator sensitivity matrix are used to deploy the resources along the feeder to achieve the control objectives. Mixed-integer nonlinear programming is used to solve the formulated optimization control problem. The methodology has been tested on the IEEE 123-feeder test system, and the results demonstrate that the proposed approach could actively tackle the voltage problem brought about by high penetrations of PV and improve the reliability of distribution system operation.

14 SOLAR ENERGY↗

Thermal performance sensitivity studies in support of material modeling for extended storage of used nuclear fuel

The work reported here is an investigation of the sensitivity of component temperatures of a storage system, including fuel cladding temperatures, in response to age-related changes that could degrade the design-basis thermal behavior of the system. The purpose of these sensitivity studies is to provide a realistic example of how changes in the physical properties or configuration of the storage system components can affect temperatures and temperature distributions. The magnitudes of these sensitivities can provide guidance for identifying appropriate modeling assumptions for thermal evaluations extending long term storage out beyond 50, 100, 200, and 300 years.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On the Use of Energy Storage Technologies for Regulation Services in Electric Power Systems with Significant Penetration of Wind Energy

Energy produced by intermittent renewable resources is sharply increasing in the United States. At high penetration levels, volatility of wind power production could cause additional problems for the power system balancing functions such as regulation. This paper reports some partial results of a project work, recently conducted by the Pacific Northwest National Laboratory (PNNL) for Bonneville Power Administration (BPA). The project proposes to mitigate additional intermittency with the help of Wide Area Energy Management System (WAEMS) that would provide a two-way simultaneous regulation service for the BPA and California ISO systems by using a large energy storage facility. The paper evaluates several utility-scale energy storage technology options for their usage as regulation resources. The regulation service requires a participating resource to quickly vary its power output following the rapidly and frequently changing regulation signal. Several energy storage options have been analyzed based on thirteen selection criteria. The evaluation process resulted in the selection of flywheels, pumped hydro electric power (or conventional hydro electric power) plant and sodium sulfur or nickel cadmium batteries as candidate technologies for the WAEMS project. A cost benefit analysis should be conducted to narrow the choice to one technology.

17 WIND ENERGY↗

State of Common Grid Services Definitions

This document is prepared as part of the Department of Energy’s Grid Modernization Laboratory Consortium (GMLC) 2.5.2 project, whose goal is to develop and socialize a common set of grid service definitions relevant to grid-related interactions with distributed energy resources (DER: responsive generation, storage, and loads), and to advance the concept and requirements of the Energy Services Interface (ESI) to the point of launching related interface standards and guides that can be implemented in communication protocols and business process definitions. The notion of “grid services” is integral to the definition of an ESI because a key principle of the ESI is that it permits coordination between grid operators and DER facilities in a way that is service-oriented, with an understanding of performance expectations. This document reviews the current state of grid service definitions, including those actively used in the market today as well as new services that have been proposed for future implementation. The document describes grid services used in transmission as well as distribution systems. In defining grid services, this document also distinguishes between two fundamental concepts: an “operational objective” and a “grid service,” which describes a generator’s or customer’s expected physical performance in delivering power to or consuming power from the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WGRID-49 GMLC Project Report: Understanding the Role of Short-Term Energy Storage and Large Motor Loads for Active Power Controls by Wind Power

The GMLC project is built upon the results of pioneering research funded by the U.S. Department of Energy (DOE) and conducted by the National Renewable Energy Laboratory (NREL)—in collaboration with the Electric Power Research Institute and the University of Colorado—on active power controls (APC) by wind power during 2013–2016. The studies detailed in the first APC by wind power project have shown tremendous promise for the potential for wind power plants to provide APC. The goal of this project was to continue the previous work and develop and validate coordinated controls of APC by wind generation, short-term energy storage, and large industrial motor drives for providing various types of ancillary services to the grid and minimizing loading impacts on wind turbines (e.g., drivetrains), thereby reducing operation-and-maintenance (O&M) costs and subsequently reducing the cost of energy generated by wind power. This work used the $30 million, multiyear DOE investments and the unique characteristics of NREL’s existing National Wind Technology Center test site, including a combination of multimegawatt utility-scale wind turbine generators, a 1-MW/1-MWh battery energy storage system (BESS), industrial variable-frequency motor drives, a 1-MW solar photovoltaic (PV) array, and a 7-MVA controllable grid interface. This combination of technologies allows for the optimization, testing, and demonstration of various types of APC by wind power in coordination with other generation sources (including regenerative loads) and energy storage to allow for enhancing or, in some cases, substituting the APC services by wind power and reducing impacts on wind turbine component life and thus increasing the availability and reliability of the power supply from wind

17 WIND ENERGY↗

Final Technical Report Wireless Microsensors System for Monitoring Deep Subsurface Operations

This final technical report describes the main findings of the project Wireless Microsensors System for Monitoring Deep Subsurface Operations (FE0031850). The project was part of the U.S. Department of Energy National Energy Technology Laboratory FOA 1998 program to develop new sensor systems for direct observation of parameters associated with CO2 injection and to provide data collection without being disruptive to operations. The overall DOE program was aimed at developing and validating innovative transformational sensor systems, amenable for integration with autonomous intelligent monitoring systems, that are capable of being deployed within the casing annulus and do not have casing perforation or wires/cables in the annulus for installation, power supply, or data transmission needs. Project accomplishments included 1) design and fabrication of a wireless downhole sensor system to monitor parameters for CO2 storage, 2) field testing of the sensor system in two legacy oil & gas wells, and 3) development of an analysis approach that validates the measurements and demonstrates the application of the technology to depict CO2 movement in the subsurface. The project leveraged new sensor technologies along with specialized wellbore telemetry, deployment, and analysis methods designed to address the challenges and risks related to CO2 storage in the subsurface. Results from field testing were a mixture of successes and challenges. The temperature sensor rings, installation procedures in legacy oil & gas wells, wireless powering demonstration, automated data collection, and material compatibility were successful. The wireless data transfer through cement to the wellhead via the sensor relays was not functional beyond the first relay. Consequently, work in the last year of the project included some additional testing of data transmission through different materials along with modeling and analysis of field data for CO2 monitoring applications. This work suggested there are options like polymer cements and open hole annuli that may allow point-to-point transmission along the borehole. The techno-economic analysis suggests that the sensor system is ~40% less expensive than fiber optic distributed temperature system. Modeling of CO2 storage applications suggests temperature can provide an indicator of CO2 saturation but would be best combined with pressure sensors.

47 OTHER INSTRUMENTATION↗

Merefa Community Microgrid: Conceptual Design and Sequence of Operations [Slides]

A conceptual design is described for a community microgrid in Ukraine. Microgrid resources include solar photovoltaics, battery energy storage, and conventional natural gas fueled reciprocating engine generators. The conceptual architecture was informed by the microgrid developer, NREL subject matter experts, and the application of REopt, an NREL-developed software tool created for identification of least-cost combination of resources for achieving cost savings, resilience, and renewable energy goals. The report includes conceptual architecture, estimates of key summary financial metrics, and sequence of operations.

14 SOLAR ENERGY↗