Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric utility programs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Investigation of Donor and Acceptor Ion Implantation in AlN

AlGaN alloys with high Al composition and AlN based electronic devices are attractive for high voltage, high temperature applications, including microwave power sources, power switches and communication systems. AlN is of particular interest because of its wide bandgap of ~6.1eV which is ideal for power electronic device applications in extreme environments which requires high dose ion implantation. One of the major challenges that need to be addressed to achieve full utilization of AlN for opto and microelectronic applications is the development of a doping strategy for both donors and acceptors. Ion implantation is a particularly attractive approach since it allows for selected-area doping of semiconductors due to its high spatial and dose control and its high throughput capability. Active layers in the semiconductor are created by implanting a dopant species followed by very high temperature annealing to reduce defects and thereby activate the dopants. Recovery of implant damage in AlN requires excessively high temperature. In this SBIR program we began the investigation by simulation of ion beam implantation profiles for Mg, Ge and Si in AlN over wide dose and energy ranges. Si and Ge are implanted to achieve the n-type doping, Mg is investigated as a p-type doping. The simulation of implantation profiles were performed in collaboration between NRL and Agnitron using a commercial software known as Stopping and Range of Ions in Matter (SRIM). The simulation results were then used as the basis for ion implantation of AlN samples. The implanted samples were annealed by an innovative technique under different conditions and evaluated along the way. Raman spectroscopy and XRD were used to determine the crystal quality of the implanted samples, demonstrating the effectiveness of annealing in removing implant induced damage. Additionally, SIMS was used to verify that a nearly uniform doping profile was achieved near the sample surface. The electrical characteristics of the implanted samples were evaluated by TLM and Hall techniques. Generally, the implanted samples before and after annealing were found to be very resistive. Further work is required before the superior properties of AlN can be fully utilized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strategy Guideline: Mitigation of Retrofit Risk Factors

The Alliance for Residential Building Innovation (ARBI) is currently developing strategies designed to promote and achieve increased energy savings and promote upgrades in the residential retrofit sector. These strategies are targeted to retrofit program managers, retrofit contractors, policy makers, academic researchers, and non-governmental organizations. This report focuses on four key areas to promote home energy upgrades: fostering accurate energy savings projections; understanding consumer perceptions for energy savings; measuring energy savings, and ensuring quality control for retrofit installations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Management of Risk and Uncertainty Through Optimized Co-Operation of Transmission Systems and Microgrids with Responsive Loads (Final Report)

The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EERE's State & Local Energy Data Tool

EERE's State and Local Energy Data (SLED) Tool provides basic energy market information that can help state and local governments plan and implement clean energy projects, including electricity generation; fuel sources and costs; applicable policies, regulations, and financial incentives; and renewable energy resource potential. Watch this video to learn more about the tool and hear testimonials from real users about the benefits of using this tool.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Decarbonization Technology Snapshot: Heat Pump Water Heaters

Heat pump water heaters use electricity to move heat from one place to another instead of generating heat directly. In many cases they replace gas-fired water heaters and are significantly more energy efficient, reducing on-site Scope 1 emissions and often resulting in reduced total emissions.

building decarbonization↗

Residential Water Heating Demand Side Management (DSM) - South Africa

The electricity crisis in South Africa has deteriorated significantly, with the country experiencing frequent and prolonged rolling blackouts. These outages have severe economic repercussions, leading to decreased growth and productivity. Demand Side Management (DSM), particularly focusing on electric water heaters due to their significant energy consumption and peak demand contribution, is identified as a key strategy. The study aims to assess opportunities for DSM programs targeting water heating to reduce energy consumption and peak demand. It entails developing a bottom-up simulation model to establish a baseline scenario of water heating electricity load demand in 2023 and 2033, identifying technologies for energy reduction, estimating the impacts of a selected number of measures and providing recommendations to inform policy makers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alternative Fuel and Advanced Technology Commercial Lawn Equipment (Brochure)

The U.S. Department of Energy's Clean Cities program produced this guide to help inform the commercial mowing industry about product options and potential benefits. This guide provides information about equipment powered by propane, ethanol, compressed natural gas, biodiesel, and electricity, as well as advanced engine technology. In addition to providing an overview for organizations considering alternative fuel lawn equipment, this guide may also be helpful for organizations that want to consider using additional alternative fueled equipment.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Operational and Strategic Implementation of Dynamic Line Rating for Optimized Wind Energy Generation Integration

One primary goal of rendering today’s transmission grid “smarter” is to optimize and better manage its power transfer capacity in real time. Power transfer capacity is affected by three main elements: stability, voltage limits, and thermal ratings. All three are critical, but thermal ratings represent the greatest opportunity to quickly, reliably and economically utilize the grid’s true capacity. With the “Smarter Grid”, new solutions have been sought to give operators a better grasp on real time conditions, allowing them to manage and extend the usefulness of existing transmission infrastructure in a safe and reliable manner. The objective of the INL Wind Program is to provide industry a Dynamic Line Rating (DLR) solution that is state of the art as measured by cost, accuracy and dependability, to enable human operators to make informed decisions and take appropriate actions without human or system overloading and impacting the reliability of the grid. In addition to mitigating transmission line congestion to better integrate wind, DLR also offers the opportunity to improve the grid with optimized utilization of transmission lines to relieve congestion in general. As wind-generated energy has become a bigger part of the nation’s energy portfolio, researchers have learned that wind not only turns turbine blades to generate electricity, but can cool transmission lines and increase transfer capabilities significantly, sometimes up to 60 percent. INL’s DLR development supports EERE and The Wind Energy Technology Office’s goals by informing system planners and grid operators of available transmission capacity, beyond typical Static Line Ratings (SLR). SLRs are based on a fixed set of conservative environmental conditions to establish a limit on the amount of current lines can safely carry without overheating. Using commercially available weather monitors mounted on industry informed custom brackets developed by INL in combination with Computational Fluid Dynamics (CFD) enhanced weather analysis and DLR software, INL’s project offers the potential of safely providing line ampacities up to 40 percent or more above existing SLRs, by using real time information rather than overly conservative SLR.

17 WIND ENERGY↗

Determining Utility System Value of Demand Flexibility From Grid-interactive Efficient Buildings

This report focuses on ways current methods and practices that establish the value to electric utility systems of distributed energy resource (DER) investments can be enhanced to determine the value of demand flexibility in grid-interactive efficient buildings that can provide grid services. The report introduces key valuation concepts that are applicable to demand flexibility that these buildings can provide and links to other documents that describe these concepts and their implementation in more detail.The scope of this report is limited to the valuation of economic benefits to the utility system. These are the foundational values on which other benefits (and costs) can be built. Establishing the economic value to the grid of demand flexibility provides the information needed to design programs, market rules, and rates that align the economic interest of utility customers with building owners and occupants. By nature, DERs directly impact customers and provide societal benefits external to the utility system. Jurisdictions can use utility system benefits and costs as the foundation of their economic analysis but align their primary cost-effectiveness metric with all applicable policy objectives, which may include customer and societal (non-utility system) impacts.This report suggests enhancements to current methods and practices that state and local policymakers, public utility commissions, state energy offices, utilities, state utility consumer representatives, and other stakeholders might support. These enhancements can improve the consistency and robustness of economic valuation of demand flexibility for grid services. The report concludes with a discussion of considerations for prioritizing implementation of these improvements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Demonstration of Enhanced Sorbent Injection for Mercury Control

Alstom Power Inc. has conducted a DOE/NETL-sponsored program (under DOE Cooperative Agreement No. DE-FC26-04NT42306) to demonstrate Mer-Cure{trademark}, one of Alstom's mercury control technologies for coal-fired boilers. Mer-Cure{trademark} utilizes a small amount of Mer-Clean{trademark} sorbent that is injected into the flue gas stream for oxidation and adsorption of gaseous mercury. Mer-Clean{trademark} sorbents are carbon-based and prepared with chemical additives that promote oxidation and capture of mercury. Mer-Cure{trademark} is unique in that the sorbent is injected into an environment where the mercury capture kinetics is accelerated. This full-scale demonstration program was comprised of three seven-week long test campaigns at three host sites including PacifiCorp's 240-MW{sub e} Dave Johnston Unit No.3 burning a Powder River Basin (PRB) coal, Basin Electric's 220-MW{sub e} Leland Olds Unit No.1 burning a North Dakota lignite, and Reliant Energy's 170-MW{sub e} Portland Unit No.1 burning an Eastern bituminous coal. All three boilers are equipped with electrostatic precipitators. The goals for this Round 2 program, established by DOE/NETL under the original solicitation, were to reduce the uncontrolled mercury emissions by 50 to 70% at a cost 25 to 50% lower than the previous target of $60,000/lb mercury removed. The results for all three host sites indicated that Mer-Cure{trademark} technology could achieve mercury removal of 90%. The estimated mercury removal costs were 25-92% lower than the benchmark of $60,000/lb mercury removed. The estimated costs for control, at sorbent cost of $1.25 to $2.00/lb respectively, are as follows: (1) Dave Johnston Unit No.3--$2,650 to $4,328/lb Hg removed (92.8% less than $60k/lb); (2) Leland Olds Unit No.1--$8,680 to $13,860/lb Hg removed (76.7% less than $60k/lb); and (3) Portland Unit No.1--$28,540 to $45,065/lb Hg removed (24.9% less than $60k/lb). In summary, the results from demonstration testing at all three host sites show that the goals established by DOE/NETL were exceeded during this test program. Mercury removal performance4 of greater than 90% reduction was above the 50-70% reduction goal, and mercury removal cost of 25-92% lower than the benchmark was above the 25 to 50% cost reduction goal.

01 COAL, LIGNITE, AND PEAT↗

High Efficiency Solar Power via Separated Photo and Voltaic Pathways

This project demonstrates a novel nanostructured solar cell architecture capable of achieving high efficiency levels that is relatively simple and inexpensive to manufacture. The high efficiency will be achieved by the novel structure that separates the path of the photons from the path of the generated charge carriers. In this way, the photon path can be long for maximum light absorption, while the path for carriers can be short for maximum electronic energy harvesting. The combination of maximum light absorption coupled with maximum carrier harvesting is the basis for the expected high efficiency. The project will develop high efficiency solar cell prototypes utilizing this unique nanostructured architecture. The project addresses the fundamental limitation inherent in all current solar cell designs, and which opens a pathway to development for high efficiency solar cells at low cost. Realizing this goal will result in a levelized cost of electricity in the range of 10¢/kWh, which would achieve the long-sought goal of making photovoltaic electricity cost competitive with fossil-fuel generated electricity without any governmental subsidies. This breakthrough would spur the already rapid growth in the photovoltaic industry to an explosive pace, with significant, widespread benefit to the national economy and the nation’s energy security. The initial target of the program is to develop single-junction solar cells using ultrathin amorphous silicon with the performance approaching that of single crystal silicon cells.

14 SOLAR ENERGY↗

Evaluation of Missed Energy Saving Opportunity Based on Illinois Home Performance Program Field Data: Homeowner Selected Upgrades vs. Cost-Optimized Solutions; Chicago, Illinois (Fact Sheet)

Expanding on previous research by PARR, this study compares measure packages installed during 800 Illinois Home Performance with ENERGY STAR (IHP) residential retrofits to those recommended as cost-optimal by Building Energy Optimization (BEopt) modeling software. In previous research, cost-optimal measure packages were identified for fifteen Chicagoland single family housing archetypes, called housing groups. In the present study, 800 IHP homes are first matched to one of these fifteen housing groups, and then the average measures being installed in each housing group are modeled using BEopt to estimate energy savings. For most housing groups, the differences between recommended and installed measure packages is substantial. By comparing actual IHP retrofit measures to BEopt-recommended cost-optimal measures, missed savings opportunities are identified in some housing groups; also, valuable information is obtained regarding housing groups where IHP achieves greater savings than BEopt-modeled, cost-optimal recommendations. Additionally, a measure-level sensitivity analysis conducted for one housing group reveals which measures may be contributing the most to gas and electric savings. Overall, the study finds not only that for some housing groups, the average IHP retrofit results in more energy savings than would result from cost-optimal, BEopt-recommended measure packages, but also that linking home categorization to standardized retrofit measure packages provides an opportunity to streamline the process for single family home energy retrofits and maximize both energy savings and cost-effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Northwest Energy Efficient Manufactured Housing Program Specification Development

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrofuels: More Efficient Than Photosynthesis

The Advanced Research Projects Agency -- Energy (ARPA-E) has funded successful programs with OPXBIO, NC State and others to create hyper efficient processes for manufacturing biofuels and electrofuels, which can be used in the existing transportation infrastructure.

09 BIOMASS FUELS↗

On the Path to Energy Independence and a Clean Power Future – LED Lighting Retrofit and Solar Power Generation for the CTUIR Science and Engineering Laboratory and Public Transit Center (Rev.1)

This project supports the goals of the Energy Policy for the Confederated Tribes of the Umatilla Indian Reservation (CTUIR) through the implementation of an energy efficiency measure (LED lighting retrofit) and construction of a fixed rack (stationary) ground-mounted solar photovoltaic (PV) array energy generation system. The project objective was to eliminate the net demand for grid-based utility energy at two tribal facilities: the CTUIR Field Station and the Public Transit Center (consisting of bus barn and maintenance shop buildings). A total of 332 lighting fixtures were retrofitted with high efficiency LEDs at the three buildings within the project scope. The solar PV array constructed adjacent to the Field Station (46330 Timine Way, Pendleton, OR 97801) has a nameplate capacity of 97.98 kW DC . The project was managed by staff from the CTUIR Energy & Environmental Sciences Program within the Department of Natural Resources and the final budget was $\$ $288,206. Data was collected during a 12 month monitoring period following construction of the aptly named Ántukš–Tín̓qapapt Solar PV Array and assessed to determine project results. During this time, the solar PV system generated 125,580 kWh of energy according to SolrenView solar PV system monitoring service. In contrast, the total realized utility energy and cost savings due to the project were estimated by comparing 24 months of consecutive utility billing data. Results of this comparison indicate that grid-based utility energy demand was reduced by 121,280 kWh, or roughly 80% of the total electricity consumed by both facilities. The cost savings associated with this energy demand reduction were $\$ $11,104 and a payback period of 5.7 years was estimated for recovering the CTUIR’s investment. However, it should be noted that these figures are not representative of the savings that could be obtained under normal, error-free (i.e. faultless) conditions. Several undesirable events occurred during the 12 month monitoring and evaluation period, the effects of which were quantified using available data so that results under a “Faultless Scenario” could be estimated. Annual energy and cost savings estimated for the Faultless Scenario were approximately 166,289 kWh and $\$ $15,225, respectively. These figures should prove to be more representative of the long-term average annual results achieved in response to the project and suggest a payback period closer to 4.5 years for the CTUIR.

14 SOLAR ENERGY↗

Eight cm technology thruster development

A structural integrated ion thruster with 8-cm beam diameter (SIT-8) was developed for attitude control and stationkeeping of synchronous satellites. As optimized, the system demonstrates a thrust T=1.14 mlb (not corrected for beam V sub B = 1200 V (I sub sp = 2200 sec) total propellant utilization efficiency nu sub u = 59.8% (is approximately 72% without auxiliary pulse-igniter electrode), and electrical efficiency n sub E 61.9%. The thruster incorporates a wire-mesh anode and tantalum cover surfaces to control discharge chamber flake formation and employs an auxiliary pulse-igniter electrode for hollow-cathode ignition. When the SIT-8 is integrated with the compatible SIT-5 propellant tankage, the system envelope is 35 cm long by 13 cm flange bolt circle with a mass of 9.8 kg including 6.8 kg of mercury propellant. Two thrust vectoring systems which generate beam deflections in two orthogonal directions were also developed under the program and tested with the 8-cm thruster. One system vectors the beam over + or - 10 degrees by gimbaling of the entire thruster (not including tankage), while the other system vectors the beam over + or - 7 degrees by translating the accel electrode relative to the screen electrode.

Hyman, J., Jr.↗

The Altus Cumulus Electrification Study (ACES): A UAV-based Investigation of Thunderstorms

The Altus Cumulus Electrification Study (ACES) is a NASA-sponsored and -led science investigation that utilizes an uninhabited aerial vehicle (UAV) to investigate thunderstorms in the vicinity of the NASA Kennedy Space Center, Florida. As part of NASA's UAV-based science demonstration program, ACES will provide a scientifically useful demonstration of the utility and promise of UAV platforms for Earth science and applications observations. ACES will employ the Altus 11 aircraft, built by General Atomics-Aeronautical Systems, Inc. By taking advantage of its slow flight speed (70 to 100 knots), long endurance, and high-altitude flight (up to 55,000 feet), the Altus will be flown near, and when possible, above (but never into) thunderstorms for long periods of time, allowing investigations to be conducted over entire storm life cycles. Key science objectives simultaneously addressed by ACES are to: (1) investigate lightning-storm relationships, (2) study storm electrical budgets, and (3) provide Lightning Imaging Sensor validation. The ACES payload, already developed and flown on Altus, includes electrical, magnetic, and optical sensors to remotely characterize the lightning activity and the electrical environment within and around thunderstorms. The ACES field campaign will be conducted during July 2002 with a goal of performing 8 to 10 UAV flights. Each flight will require about 4 to 5 hours on station at altitudes from 40,000 ft to 55,000 ft. The ACES team is comprised of scientists from the NASA Marshall Space Flight Center and NASA Goddard Space Flight Centers partnered with General Atomics and IDEA, LLC.

Blakeslee, Richard↗

Progress in Monitoring Strategies for Risk Reduction in Geologic CO2 Storage

Abstract: This geophysical monitoring review is intended to lay the ground work for an approach to integrating monitoring strategies with risk assessment and risk reduction and to summarize work conducted by U.S. Department of Energy's National Risk Assessment Partnership (NRAP) participants that addresses key questions related to monitoring strategies. Commercial, demonstration and pilot geologic CO2 storage (GCS) projects have provided a wealth of practical experience in monitoring technologies. In this manuscript we review a few key projects, specific geophysical methods, well-based methods, geophysical workflows and some suggested best practices. These practices are often driven and governed by regulatory requirements (e.g. U.S. Environmental Protection Agency [US-EPA] Class VI underground injection regulation) and the need for effective reservoir management of pressures and volumes as well as the site-specific risks to containment, plume migration, and underground sources of drinking water. Reducing uncertainty in monitoring is likely to lead to reducing uncertainty in risk. One of our conclusions is the need for field experiment testing that is risk-driven. It is notable that GCS pilot projects have been designed for safe storage, and to date they have been successful. Technical challenges at all geologic CO2 storage sites include assuring injectivity and capacity predictions are reliable, the fate and subsurface topology of the CO2 plume is acceptable, regulatory permitting and compliance are accomplished in a timely manner, needed business assurances are supported by quantitative technical data, and the storage operation is acceptable to stakeholders. There is risk associated with all of these challenges necessitating a monitoring program utilizing both direct and indirect monitoring methods. Because of the direct association of risk and monitoring in GCS, geophysical monitoring is viewed as a key component in approaching risk assessment. To address monitoring in the context of risk assessment the U.S. Department of Energy's National Risk Assessment Partnership (NRAP) has undertaken a review of work related to monitoring storage sites. In this review we provide a framework for monitoring and then present some specific monitoring tools that may be useful for regulatory compliance, as well as technologies that are applicable to leakage detection.

Harbert, William↗