Search NASA⌕ Search

SEARCH · Search NASA

Results for “electronics packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

BuildingSync® v.2.5.0 2024 [SWR-18-28]

BuildingSync® is a building data exchange schema to better enable integration between software tools and building data workflows. The schema's original use case was focused on commercial building energy audits; however, several additional use cases have been realized including building energy modeling and more high-level generic building data exchange. BuildingSync helps streamline the data exchange process, improving the value of the data, minimizing duplication of effort for subsequent building data collection efforts (including audits), and facilitating the achievement of greater energy efficiency. This in done in part by standardizing on (a) reporting audits in an electronic format, (b) tracking proposed, implemented, and discarded energy conservation measures, and (c) storing building characteristics (at multiple levels) for audits, benchmarking, and building energy analysis. BuildingSync has several documents and tools available to help users understand how to best leverage BuildingSync. The list below are only a subset of the resources available. If new resources are discovered, then feel free to create a new pull request with the additions. Generic BuildingSync information is available on the DOE website and the project website. BuildingSync Examples - These examples are kept up to date and show a wide range of implementations. Any new update to BuildingSync is required to pass validation on these example files. BuildingSync Use Case Validator allows for users to determine if their instance complies with a specific use case for BuildingSync by checking if the required elements are implemented in an uploaded instance. An API is also provided for automated integration into other tools. Also, the website contains an easy way to view the entirety of the schema and how elements relate to the Building Exchange Data Exchange Specification. The Validator is open sourced here Use Case TestSuite provides a Python package for easier generation of BuildingSync use cases. BuildingSync use cases depend on the generation of schematron documents, which is time-consuming and difficult to implement well. The TestSuite allows users to define a use case using a more palatable CSV template, which it then turns into a Schematron document. The source code is available here. BuildingSync to OpenStudio/EnergyPlus. The translator is open sourced here. This project will translate a Level 1 (and partial Level 2) ASHRAE Energy Audit to a fully defined OpenStudio and EnergyPlus model. This project is in early Beta testing and any feedback is welcome!

Long, Nicholas↗

BuildingSync® v.2.7.0 (released 9.11.2025) [SWR-18-28]

BuildingSync® is a building data exchange schema to better enable integration between software tools and building data workflows. The schema's original use case was focused on commercial building energy audits; however, several additional use cases have been realized including building energy modeling and more high-level generic building data exchange. Version 2.7.0 adds new elements for file attachment feature and FederalBuilding, and generalizes usage of Optional Elements (e.g. EquipmentCondition, EquipmentID) to all assets/systems. BuildingSync helps streamline the data exchange process, improving the value of the data, minimizing duplication of effort for subsequent building data collection efforts (including audits), and facilitating the achievement of greater energy efficiency. This in done in part by standardizing on (a) reporting audits in an electronic format, (b) tracking proposed, implemented, and discarded energy conservation measures, and (c) storing building characteristics (at multiple levels) for audits, benchmarking, and building energy analysis. BuildingSync has several documents and tools available to help users understand how to best leverage BuildingSync. The list below are only a subset of the resources available. If new resources are discovered, then feel free to create a new pull request with the additions. Generic BuildingSync information is available on the DOE website and the project website. BuildingSync Examples - These examples are kept up to date and show a wide range of implementations. Any new update to BuildingSync is required to pass validation on these example files. BuildingSync Use Case Validator allows for users to determine if their instance complies with a specific use case for BuildingSync by checking if the required elements are implemented in an uploaded instance. An API is also provided for automated integration into other tools. Also, the website contains an easy way to view the entirety of the schema and how elements relate to the Building Exchange Data Exchange Specification. The Validator is open sourced here Use Case TestSuite provides a Python package for easier generation of BuildingSync use cases. BuildingSync use cases depend on the generation of schematron documents, which is time-consuming and difficult to implement well. The TestSuite allows users to define a use case using a more palatable CSV template, which it then turns into a Schematron document. The source code is available here. BuildingSync to OpenStudio/EnergyPlus. The translator is open sourced here. This project will translate a Level 1 (and partial Level 2) ASHRAE Energy Audit to a fully defined OpenStudio and EnergyPlus model. This project is in early Beta testing and any feedback is welcome!

Long, Nicholas [National Renewable Energy Lab. (NR↗

Thermal Optimization of a Silicon Carbide, Half-Bridge Power Module

This project describes the modeling process to design the packaging and heat exchanger for a half-bridge wide-bandgap (WBG) power semiconductor module. The module uses two silicon carbide, metal-oxide-semiconductor field-effect transistor (MOSFET) devices per switch position that are soldered to an aluminum nitride, direct-bond copper (DBC) substrate. A baseplate cooling configuration (e.g., no thermal grease) is used along with a water-ethylene glycol, jet-impingement-style heat exchanger. The heat exchanger was designed to be fabricated using prototyping equipment from the National Renewable Energy Laboratory, complies with automotive standards (for minimal channel sizes, flow rates, and coolant), and considers reliability aspects (i.e., erosion/corrosion). Device-scale computational fluid dynamics (CFD) is used first to design the slot jet impingement cooling configuration and compute the effective heat transfer coefficient (HTC) of the concept. The computed HTCs are then used as boundary conditions for a finite element study to optimize the package geometry (e.g., device layout and baseplate thickness) to minimize thermal resistance and minimize temperature variation between the module's four devices. Finally, a fluid manifold is designed to generate the slot jets and cool the devices. Module-scale CFD predicts a relatively low junction-to-fluid thermal resistance of 16.7 mm2 K/W, a 1.4 degrees C temperature variation between devices, and a total pressure drop of 5,860 Pa (0.85 psi) for the design. The thermal resistance of the module design is about 67% lower than the 2015 BMW i3 power electronics/modules thermal resistance.

DIRECT ENERGY CONVERSION↗

Photostability of Ambient-Processed, Conjugated Polymer Electrochromic Devices Encapsulated by Bioderived Barrier Films

Polymer-based electrochromic devices (ECDs) are a promising technology for enabling low-voltage, disposable displays, yet are currently limited by photo-oxidative bleaching of the active materials. Here, renewable barrier films composed of cellulose and chitin are presented as an alternative to poly(ethylene terephthalate) (PET) for encapsulating ECDs. To assess barrier film effectiveness, lateral ECDs composed of poly(3,4-propylenedioxythiophene-(CH 2 OEtHx) 2 ) (P(ProDOT)) active layers were constructed and encapsulated with a multilayer barrier consisting of chitin nanofibers and cellulose nanocrystals spray cast onto a cellulose acetate substrate (oxygen transmission rate (OTR) = 29 cm 3 m –2 day –1 ), a commercially available PET film (OTR = 8.5 cm 3 m –2 day –1 ), and a high-performance PET-Al 2 O 3 multilayer barrier film (OTR < 1 cm 3 m –2 day –1 ). The photodegradation of the P(ProDOT) active layer was determined by measuring the evolution of the colorimetric contrast (ΔE*) and switching speeds as a function of light exposure (100 mW cm –2 , AM 1.5 G light). Photodegradation was found to proceed at a similar rate for all encapsulated devices (roughly 10 times more slowly than unencapsulated devices), highlighting the opportunity for replacing petroleum packaging with bioderived barrier films. Analysis of the switching kinetics, the shifts in optical absorbance, and evidence of chemical degradation indicate that both photochemical breakdown of the electrolyte and cross-linking of the P(ProDOT) active material are key drivers for loss of device performance when oxygen flux to the active material is limited. Furthermore, pathways toward better understanding photodegradation are then proposed with sustainability in mind for future ECD design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linearity for Ca2+-Doped CeBr3 Scintillating Materials

The Remote Sensing Laboratory (RSL) developed an aliovalently calcium-doped cerium tribromide (CeBr3:Ca2+) crystal with 3.2% resolution. RSL completed a crystal assessment, and Sandia National Laboratories calculated the predictive performance and physical characteristics using proven density functional theory (DFT) formalism. Results are reported for the work done to map the detector performance, characteristics, calcium doping concentration, and crystal strength. Preliminary scintillation measurements for this aliovalently calcium-doped CeBr3 scintillator exhibit a slight blue shift in fluorescence emission at 371 nm excitation for CeBr3. The structural, electronic, and optical properties of CeBr3 crystals were investigated using DFT within generalized gradient approximation. The calculated lattice parameters are in good agreement with the experimental data. The energy band structures and density of states were obtained. The optical properties of CeBr3, including the dielectric function, were calculated. Specifically, we report excellent linearity with the aliovalently calcium-doped CeBr3 crystal. Proportionality of light yield is one area of performance in which Ce-doped and Ce-based lanthanide halides excel. Maintaining proportionality is key to producing a strong, high-performance scintillator. Relative light yield proportionality was measured for both doped and undoped samples of CeBr3 to ensure no loss in performance was incurred during doping. The light output and proportionality, however, appear to be similar to CeBr3. There was a reduced yield at low energy. Relative light yield proportionality measurements suggest that dopants do not significantly affect proportionality at higher energies. RSL completed additional testing and evaluation of the new crystal and assessed benchmark spectroscopy measurements. Results, which present energy resolution as a function of energy, are summarized. Typical spectroscopy results using a 137Cs radiation source are shown for our crystallite. We obtain 4.5% for the packaged crystallite. More spectra are presented for 241Am, 60Co, 228Th, and background to exemplify CeBr3:Ca2+ over a broader energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing Low Noise, Rad-hard Detectors for Parity Violating Experiments

As parity-violating electron scattering (PVeS) experiments continue to push the frontiers of precision electro-weak asymmetry measurements, the demands on the experimental techniques and apparatus are also pushed. In particular, the need for higher resolution and radiation-hardness of the main integrating detectors has increased over the successive generations of PVeS experiments. The demand for precise measurement of GHz event rates has pushed the field toward the use of thin quartz Cerenkov light based detectors. We have been designing and testing such thin quartz detectors specifically for the upcoming experiments at Jefferson Lab, PREX-II and CREX, but this work also greatly influences the detector development for several future experiments including MOLLER at Jefferson Lab. These are all PVeS experiments that will use the new thin quartz Cerenkov detector design concept for their main asymmetry measurements (as well as for beam monitoring). The new design concept gives not only significant performance improvements compared to its predecessor from PREX-I, but also we have now thoroughly characterized its operational design and performance using a combination of test-beam data and detailed particle and optical Monte Carlo Geant4 simulations. These activities have culminated in the development and implementation of a "bench-marked" Monte Carlo package, QSIM, which constitutes a powerful design tool for present and future PVeS quartz detectors. The benchmarked simulation can replicate real photoelectron distributions (RMS and Mean) from testbeam data with ~5% precision – limited mainly by the systematic uncertainty of the PMT gain measurements.

Villarreal, Carlos Bula Villarreal↗

Subtask 1.1 – Advanced Characterization of Unconventional Oil and Gas Reservoirs to Enhance CO2 Storage Resource Estimates

The Energy & Environmental Research Center (EERC) developed methods and approaches for advanced characterization of unconventional oil and gas reservoirs to enhance CO2 storage resource estimates using samples collected from organic-rich shales of the Bakken Formation. The project was funded under U.S. Department of Energy (DOE) Cooperative Agreement No. DE-FE0024233, with nonfederal cost share provided by Hitachi High Technologies America. The project participants included the EERC, Hitachi High Technologies America, the team at the National Energy Technology Laboratory’s (NETL’s) computed tomography (CT) scanning laboratory in Morgantown, West Virginia, and several NETL staff who have worked on CO2 storage resource estimation. Investigations on the use of subsurface geologic formations for CO2 storage have been ongoing for many years. In the last decade, improvements in directional drilling technology and hydraulic fracturing of organic-rich shale and other tight rock formations have opened new opportunities for CO2 storage, with the potential cobenefit of enhancing gas and oil recovery. Gas-bearing, organic-rich shales have been of particular interest as a carbon storage target because their ability to store large volumes of CO2 is implied by their ability to store methane; however, estimating the CO2 storage resource of organic-rich shales and other unconventional reservoirs is challenging because of the lack of detailed geologic and petrophysical data that are needed to develop improved volumetric equations. According to NETL’s method for estimating regional-scale CO2 storage resources, the key factors that control CO2 storage in geologic formations include void space within induced fractures, natural fractures and matrix pores, as well as the occurrence and distribution of organic matter (OM) and clay minerals. A key goal of this effort was to use field emission scanning electron microscopy (FESEM) analysis of fine-grain unconventional reservoir rocks coupled with advanced image analysis and machine learning techniques to quantify the occurrence and distribution of porosity, OM, and clay minerals. By better understanding the potential migration pathways of CO2 within tight rocks and quantifying the occurrence of sorptive components (OM and clays) along potential flow pathways, methods to estimate the CO2 storage resource of such rocks can be refined. The Bakken petroleum system (Bakken) was used as the source of rock samples for this effort because it includes organic-rich shales with contrasting degrees of thermal maturity as well as tight, nonshale clastic rocks with varying clay mineral content. To better understand the key components of interest in tight rock samples, the EERC worked closely with Hitachi to optimize the FESEM settings necessary to resolve the sample mineralogy, porosity and OM content at micro- to nanoscale resolution. The EERC also worked closely with Hitachi to apply and improve its advanced mineral identification and characterization system (AMICS) software so that it is better suited for mineral identification at the high resolution necessary to resolve features of interest in fine-grained rocks such as organic-rich shales. The EERC also applied advanced image analysis software packages, including Ilastik, to classify and quantify the key components of interest within the samples using FESEM imagery. These advanced techniques allowed for quantification and differentiation of the void space within fractures, pores and OM, as well as a technique to determine and quantify the key mineral and OM components surrounding pore spaces. Being able to better quantify the void space and the potential accessibility of CO2 to sorptive minerals or OM within tight rocks allows for improved estimation of the CO2 storage resource potential of organic-rich shales and other unconventional formations. The information derived from the image analysis techniques was used to refine NETL’s method for estimating regional-scale CO2 storage resources in collaboration with staff from NETL. An additional goal of this work was to better understand rates of CO2 permeation, flow pathways, and sorption in organic-rich shales and nonshale reservoir rocks and to evaluate potential changes in CO2 flow over time. The EERC conducted long-duration (several weeks) CO2 flow-through testing at reservoir conditions using Bakken shale and nonshale samples to assess CO2 permeation rates and retention/sorption within core plugs to represent bulk matrix behavior. Conventional isothermal adsorption testing over a range of pressure conditions was also performed on pulverized Bakken samples to better assess potential maximum sorptive capacity of the samples. The results of this testing illustrated the higher sorptive capacity of the Bakken shales when compared to the sorptive capacity of the nonshale reservoir rock, which contains very little OM when compared to the Bakken shales. The results also illustrate the differences in permeation behavior as a function of fracture flow versus matrix flow. In an attempt to visualize CO2 permeation and flow behavior in Bakken shale samples over time, the EERC collaborated with NETL’s CT Lab in Morgantown, West Virginia. A variety of tests were performed at the NETL lab on unfractured and fractured samples of the Bakken shale. The unfractured Bakken shale samples did not result in CO2 migration within the samples over the testing duration; thus imagery of CO2 migration pathways within the matrix of Bakken samples was not obtained. The results of the flow-through testing within fractured samples illustrate changes in CO2 permeation rates over time, with a trend of decreasing CO2 flow over time. The results of this effort suggest that FESEM analysis coupled with advanced image analysis and machine learning techniques are effective in characterizing and quantifying the mineralogy, porosity, fractures, and OM content of 2-D imagery at the high resolution needed to identify features of interest in tight rocks. In addition, the image analysis techniques allow for identification and quantification of different porosity types as well as the key mineral components and/or OM that CO2 would contact in the reservoir as it migrates through pores and fracture networks. This is key information needed to better estimate the CO2 storage resource potential of organic-rich shales and other tight reservoirs. Additional work is needed to determine the sorptive capacity of the individual sample components (OM and clay minerals) at reservoir conditions so that this approach and the refined CO2 storage resource equation can be applied to other shale and unconventional reservoirs. In addition, subsequent work should be performed to better understand the number of images needed to use stereological approaches to estimate the volume of sample components using 2-D imagery, to explore machine learning techniques to differentiate between induced vs. natural fractures, and to estimate the connectivity of pores and fracture networks using 2-D imagery. Being able to derive this information at the microscale would facilitate scaling up of the sample characterization data used for reservoir modeling and simulation to estimate the CO2 storage resource potential of tight formations.

03 NATURAL GAS↗

NEET Enhanced Micro Pocket Fission Detector for High Temperature Reactors - FY15 Status Report

A new project, that is a collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Atomic Energy Agency, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), has been initiated by the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) program for developing and testing High Temperature Micro-Pocket Fission Detectors (HT MPFD), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package for temperatures up to 800 °C. The MPFD technology utilizes a small, multi-purpose, robust, in-core parallel plate fission chamber and thermocouple. As discussed within this report, the small size, variable sensitivity, and increased accuracy of the MPFD technology represent a revolutionary improvement over current methods used to support irradiations in US Material Test Reactors (MTRs). Previous research conducted through NEET ASI1-3 has shown that the MPFD technology could be made robust and was successfully tested in a reactor core. This new project will further the MPFD technology for higher temperature regimes and other reactor applications by developing a HT MPFD suitable for temperatures up to 800 °C. This report summarizes the research progress for year one of this three year project. Highlights from research accomplishments include: A joint collaboration was initiated between INL, KSU, and CEA. Note that CEA is participating at their own expense because of interest in this unique new sensor. An updated HT MPFD design was developed. New high temperature-compatible materials for HT MPFD construction were procured. Construction methods to support the new design were evaluated at INL. Laboratory evaluations of HT MPFD were initiated. Electrical contact and fissile material plating has been performed at KSU. Updated detector electronics are undergoing evaluations at KSU. A project meeting was held at KSU to discuss the roles and responsibilities between INL and KSU for development of the HT MPFDs. Provide input to various irradiation programs for installation of the MPFD technology in irradiation tests. As documented in this report, FY15 funding has allowed the project to meet year one planned accomplishments to develop a HT MPFD that offers US MTR users enhanced capabilities for real-time measurement of flux and temperature with a single detector. In addition, the accomplishments of this project have attracted funding from other Department of Energy Office of Nuclear Energy (DOE-NE) programs for additional applications. The work in those programs will build on current activities completed in this NEETASI HT MPFD project, but the MPFD will be specifically tailored to meet their program needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Frame average optimization of cine-mode EPID images used for routine clinical in vivo patient dose verification of VMAT deliveries

Purpose: The in vivo 3D dose delivered to a patient during volumetric modulated arc therapy (VMAT) delivery can be calculated using electronic portal imaging device (EPID) images. These images must be acquired in cine-mode (i.e., “movie” mode) in order to capture the time-dependent delivery information. The angle subtended by each cine-mode EPID image during an arc can be changed via the frame averaging number selected within the image acquisition software. A large frame average number will decrease the EPID’s angular resolution and will result in a decrease in the accuracy of the dose information contained within each image. Alternatively, less EPID images acquired per delivery will decrease the overall 3D patient dose calculation time, which is appealing for large-scale clinical implementation. Therefore, the purpose of this study was to determine the optimal frame average value per EPID image, defined as the highest frame averaging that can be used without an appreciable loss in 3D dose reconstruction accuracy for VMAT treatments. Methods: Six different VMAT plans and six different SBRT-VMAT plans were delivered to an anthropomorphic phantom. Delivery was carried out on a Varian 2300ix model linear accelerator (Linac) equipped with an aS1000 EPID running at a frame acquisition rate of 7.5 Hz. An additional PC was set up at the Linac console area, equipped with specialized frame-grabber hardware and software packages allowing continuous acquisition of all EPID frames during delivery. Frames were averaged into “frame-averaged” EPID images using MATLAB. Each frame-averaged data set was used to calculate the in vivo dose to the patient and then compared to the single EPID frame in vivo dose calculation (the single frame calculation represents the highest possible angular resolution per EPID image). A mean percentage dose difference of low dose (<20% prescription dose) and high dose regions (>80% prescription dose) was calculated for each frame averaged scenario for each plan. The authors defined their unacceptable loss of accuracy as no more than a ±1% mean dose difference in the high dose region. Optimal frame average numbers were then determined as a function of the Linac’s average gantry speed and the dose per fraction. Results: The authors found that 9 and 11 frame averages were suitable for all VMAT and SBRT-VMAT treatments, respectively. This resulted in no more than a 1% loss to any of the dose region’s mean percentage difference when compared to the single frame reconstruction. The optimized number was dependent on the treatment’s dose per fraction and was determined to be as high as 14 for 12 Gy/fraction (fx), 15 for 8 Gy/fx, 11 for 6 Gy/fx, and 9 for 2 Gy/fx. Conclusions: The authors have determined an optimal EPID frame averaging number for multiple VMAT-type treatments. These are given as a function of the dose per fraction and average gantry speed. These optimized values are now used in the authors’ clinical, 3D, in vivo patient dosimetry program. This provides a reduction in calculation time while maintaining the authors’ required level of accuracy in the dose reconstruction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Scalar relativistic computations of nuclear magnetic shielding and g-shifts with the zeroth-order regular approximation and range-separated hybrid density functionals

Density functional theory (DFT) calculations of NMR chemical shifts and molecular g-tensors with Gaussian-type orbitals are implemented via second-order energy derivatives within the scalar relativistic zeroth order regular approximation (ZORA) framework. Nonhybrid functionals, standard (global) hybrids, and range-separated (Coulomb-attenuated, long-range corrected) hybrid functionals are tested. Origin invariance of the results is ensured by use of gauge-including atomic orbital (GIAO) basis functions. The new implementation in the NWChem quantum chemistry package is verified by calculations of nuclear shielding constants for the heavy atoms in HX (X=F, Cl, Br, I, At) and H2X (X = O, S, Se, Te, Po), and Te chemical shifts in a number of tellurium compounds. The basis set and functional dependence of g-shifts is investigated for 14 radicals with light and heavy atoms. The problem of accurately predicting F NMR shielding in UF6-nCln, n = 1 to 6, is revisited. The results are sensitive to approximations in the density functionals, indicating a delicate balance of DFT self-interaction vs. correlation. For the uranium halides, the results with the range-separated functionals are mixed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

National Opacity Program: Analysis of Opacity-relevant X-ray Emission Spectra (Milestone Report ID 7121)

We have produced high energy density iron plasmas at temperatures above 1 keV and electron densities exceeding 1023 cm -3 (~ 1 g/cm 3 ) using the Orion laser at the Atomic Weapons Establishment. These plasmas were created by irradiating 50 µm diameter layered targets with frequency doubled (λ = 527 nm), 1 ps laser pulses focused to a 100 µm diameter producing an irradiance of ~ 2 x 10 18 W/cm 2 . The buried layer targets consist of 160 nm iron sulfide (FeS), 60 nm potassium chloride (KCl), and 15 nm carbon. The combined layers are tamped on both sides with 3 µm of parylene-N. The x-ray emission from the plasma was measured using two time-resolved, and four time-integrated Bragg crystal spectrometers, as well as one time-integrated imaging system. One time-resolved x-ray spectrometer measured emission from L-shell transitions in highly charged iron, the other from K-shell transitions in helium-like S 14+ and hydrogen-like S 15+ . The time-integrated spectrometers are intensity-calibrated and measured emission from K-shell transitions in sulfur, potassium, chlorine, and both K-shell and L-shell transitions in iron. The density and temperature of the plasma were determined by modeling the x-ray spectra using different spectral and hydrodynamic modeling packages. A brief overview of the uncertainties associated with the measurements and models are presented. We also give an overview of our 1-D HYDRA-DCA radiation-hydrodynamics model and improvements for future work. Our results aid in assessing experimental uncertainties associated with plasma uniformity and with x-ray emission employed as diagnostics in opacity experiments at temperatures and densities not achievable elsewhere and represent a significant step in creating and diagnosing plasmas near LTE. These results are summarized as part of the completion requirements for milestone 7121

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

R&D of a high-performance DIRC detector for a future electron-ion collider

An Electron-Ion Collider (EIC) is proposed as the next big scientific facility to be built in the United States, costing over $1 billion in design and construction. Each detector concept for the electron/ion beam interaction point is integrated into a large solenoidal magnet. The necessity for excellent hadronic particle identification (pion/kaon/proton) in the barrel region of the solenoid has pushed research and development (R&D) towards a new, high-performance Detection of Internally Reflected Cherenkov light (DIRC) detector design. The passage of a high energy charged particle through a fused silica bar of the DIRC generates optical Cherenkov radiation. A large fraction of this light propagates by total internal reflection to the end of the bar, where the photon trajectories expand in a large volume before reaching a highly segmented photo-detector array. The spatial and temporal distribution of the Cherenkov light at the photo-detector array allows one to reconstruct the angle of emission of the light relative to the incident charged particle track. In order to reach the desired performance of 3sigma pi/K separation at 6 GeV/c particle momentum a new 3-layer spherical lens focusing optic with a lanthanum crown glass central layer was designed to have a nearly at focal plane. In order to validate the EIC DIRC simulation package, a synergistic test beam campaign was carried out in 2015 at the CERN PS with the PANDA Barrel DIRC group using a prototype DIRC detector. Along with the analysis of the CERN test beam data, measurements of the focal plane of the 3-layer lens were performed using a custom-built laser setup at Old Dominion University. Radiation hardness of the lanthanum crown glass was tested using a 160 keV X-ray source and a monochromator at the Catholic University of America. Results of these test-bench experiments and the analysis of the 2015 CERN test beam data are presented here.

43 PARTICLE ACCELERATORS↗

Implementation of real‐time TDDFT for periodic systems in the open‐source PySCF software package

Abstract We present a new implementation of real‐time time‐dependent density functional theory (RT‐TDDFT) for calculating excited‐state dynamics of periodic systems in the open‐source Python‐based PySCF software package. Our implementation uses Gaussian basis functions in a velocity gauge formalism and can be applied to periodic surfaces, condensed‐phase, and molecular systems. As representative benchmark applications, we present optical absorption calculations of various molecular and bulk systems and a real‐time simulation of field‐induced dynamics of a (ZnO) 4 molecular cluster on a periodic graphene sheet. We present representative calculations on optical response of solids to infinitesimal external fields as well as real‐time charge‐transfer dynamics induced by strong pulsed laser fields. Due to the widespread use of the Python language, our RT‐TDDFT implementation can be easily modified and provides a new capability in the PySCF code for real‐time excited‐state calculations of chemical and material systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Heuristic Approach to Remove the Background Intensity on White-light Solar Images. I. STEREO /HI-1 Heliospheric Images

White-light coronal and heliospheric imagers observe scattering of photospheric light from both dust particles (the F-Corona) and free electrons in the corona (the K-corona). The separation of the two coronae is thus vitally important to reveal the faint K-coronal structures (e.g., streamers, co-rotating interaction regions, coronal mass ejections, etc.). However, the separation of the two coronae is very difficult, so we are content in defining a background corona that contains the F- and as little K- as possible. For both the LASCO-C2 and LASCO-C3 coronagraphs aboard the Solar and Heliospheric Observatory ( SOHO ) and the white-light imagers of the SECCHI suite aboard the Solar Terrestrial Relationships Observatory ( STEREO ), a time-dependent model of the background corona is generated from about a month of similar images. The creation of such models is possible because the missions carrying these instruments are orbiting the Sun at about 1 au. However, the orbit profiles for the upcoming Solar Orbiter and Solar Probe Plus missions are very different. These missions will have elliptic orbits with a rapidly changing radial distance, hence invalidating the techniques in use for the SOHO /LASCO and STEREO /SECCHI instruments. We have been investigating techniques to generate background models out of just single images that could be used for the Solar Orbiter Heliospheric Imager and the Wide-field Imager for the Solar Probe Plus packages on board the respective spacecraft. In this paper, we introduce a state-of-the-art, heuristic technique to create the background intensity models of STEREO /HI-1 data based solely on individual images, report on new results derived from its application, and discuss its relevance to instrumental and operational issues.

79 ASTRONOMY AND ASTROPHYSICS↗

Decision-Making Framework to Evaluate Opportunities for Recovery of Rare Earth Elements and Critical Minerals in Produced Water Networks

Oil and gas development activities require a significant amount of water. Given the environmental impacts associated with high consumption and subsequent disposal of this water, there is a need for strategies to support effective reuse of, treatment of, and/or resource recovery from this produced water. These streams can contain appreciable concentrations of rare earth elements (REE) and critical minerals (CM) (e.g., Lithium), which are critical for many important applications in electronics, technology, manufacturing, energy, and medicine [1]. Along with REE/CM present in produced water, other waste streams such as fly ash from coal-fired power plants and acid mine discharge present other potential sources for recovery of REE/CM [2-4]. And with increases in demand for REE/CM, the need for recovery from wastewater streams is becoming even more important. There is a need to develop effective decision-making tools to evaluate the economic and environmental potential for REE/CM recovery from produced water networks while supporting the needs of drilling and hydraulic fracturing activities. In this work, we present our progress in developing a decision-making framework to efficiently design and operate produced water networks for REE/CM recovery. Our approach considers REE/CM recovery from produced water streams alongside other potential wastewater sources. The models consider the location and capacity of storage and decentralized treatment processes as well as the design and operation of pipeline and transportation networks to connect different sources and effectively schedule inventories, reuse, and recovery opportunities. We focus on the evaluation of opportunities for REE/CM recovery with treatment constraints on composition and flow. We demonstrate this framework with an illustrative case study that features diverse production sites, storage facilities, transportation, and treatment sites. This proposed framework will be deployed in an open-source software package that is compatible with the PARETO framework to deliver analysis and decision-making tools that allow stakeholders to quantitatively evaluate potential opportunities for REE/CM recovery in produced water networks.

Pulsipher, Joshua↗

Linearity for Ca2+-Doped CeBr3 Scintillating Materials

The National Security Technologies, LLC, Remote Sensing Laboratory (RSL) developed an aliovalently calcium-doped cerium tribromide (CeBr3:Ca2+) crystal with a FWHM resolution of 3.2% at the 137Cs 662 keV gamma energy. RSL completed a crystal assessment and Sandia National Laboratories calculated the predictive performance and physical characteristics using proven density functional theory (DFT) formalism. Results are reported for the work done to map the detector performance, characteristics, calcium doping concentration, and crystal strength. Preliminary scintillation measurements for this aliovalently calcium-doped CeBr3 scintillator exhibit a slight blue shift in fluorescence emission at 371 nm excitation for CeBr3. The structural, electronic, and optical properties of CeBr3 crystals were investigated using the DFT within generalized gradient approximation. The calculated lattice parameters are in good agreement with the experimental data. The energy band structures and density of states were obtained. The optical properties of CeBr3, including the dielectric function of photons per unit energy, were calculated. Specifically, we report excellent linearity with the aliovalent CeBr3:Ca2+ crystal. Proportionality of light yield is one area of performance in which Ce-doped and Ce-based lanthanide halides excel. Maintaining proportionality is the key to producing a strong, high-performance scintillator. Relative light yield proportionality was measured for both doped and undoped samples of CeBr3 to ensure no loss in performance was incurred by doping. The light output and proportionality, however, appear to be similar to CeBr3. There was a reduced yield at low energy. Relative light yield proportionality measurements suggest that dopants do not significantly affect proportionality at higher energies. RSL completed additional testing and evaluation of the new crystal as well as the assessment of benchmarking spectroscopy. Results, which present energy resolution as a function of energy, are summarized. Typical spectroscopy results using a 137Cs radiation source are shown for our crystallites with diameters <1 cm. We obtain 3.2% before packing the crystallite in a sealed detector container and 4.5% for the packaged crystallite. More spectra were obtained for 241Am, 60Co, 228Th, and background to exemplify CeBr3:Ca2+ over a broader energy range.

aliovalent substitution↗

Mapping Rydberg States of H 2 with the Halfium R-Matrix Method

In this article, we use the Halfium R-matrix method to investigate the Rydberg states of the H 2 molecule up to n = 20, filling the gap above the low-lying bound states already calculated with configuration interaction packages. Moreover, we show that the use of Quantum Defect Theory scaling laws, allows for a comprehensive analysis of the regular patterns resulting from the coupling between Rydberg series and doubly excited states. The results should open the door for more efficient quasi-diabatization of the potential energy curves which is required for calculating cross sections and rate coefficients of the (e + H 2 + ) collisional processes, involved in the plasma modeling for fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LLE Review 114 (January-March 2008)

This volume of the LLE Review, covering January-March 2008, features 'Cryogenic Targets: Current Status and Future Development', by D. R. Harding, D. H. Edgell, M. D. Wittman, L. M. Elasky, S. J. Verbridge, A. J. Weaver, L. D. Lund, W. Seka, W. T. Shmayda, R. T. Janezic, M. J. Shoup III, M. Moore, R. Junquist, and A. V. Okishev. In this article (p. 57), the authors report on the status of layering cryogenic DT and D{sub 2} targets at LLE for inertial confinement fusion (ICF) targets. This critical effort achieves the important milestone of routinely providing cryogenic DT targets that meet the 1.0-{micro}m (rms) OMEGA ice-quality-surface specification. The best D{sub 2}-ice layers produced so far (rms roughness of 1.1 {micro}m) are approaching the quality typically achieved in DT targets. Efforts to improve the consistency of this process are reported along with investigations supporting the National Ignition Campaign studying issues relevant to indirect-drive and direct-drive cryogenic targets. Additional highlights of recent research presented in this issue include the following: (1) an improved laser speckle smoothing scheme that augments the current NIF 1-D SSD system by using multiple-FM modulators (MultiFM 1-D SSD) (p. 73). With a judicious choice of modulator frequencies, MultiFM 1-D SSD smoothes resonances produced at the higher spatial frequencies and can attain similar or even faster smoothing rates compared to the baseline NIF 2-D SSD system. DRACO simulations have shown that MultiFM 1-D SSD beam smoothing is sufficient for the direct-drive-ignition targets and pulse shapes analyzed thus far, and may even allow reducing the bandwidth enough to eliminate the need for dual-tripler frequency conversion on the NIF. (2) describes a time-gated, monoenergetic proton radiography that provides unique measurements of implosion dynamics of spherical targets in direct-drive inertial confinement fusion (ICF) (p. 81). Radiographs obtained at different implosion times, from acceleration, through coasting, deceleration, to final stagnation, display a comprehensive picture of spherical ICF implosion. Critical information inferred from such images characterizes the spatial structure and temporal evolution of self-generated fields and plasma areal density. (3) describes a single-shot cross-correlator based on a pulse replicator that produces a discrete sequence of sampling pulses that are nonlinearly mixed with the pulse under test (p. 86). The combination of a high reflector and partial reflector replicates an optical pulse by multiple internal reflections and generates a sequence of spatially displaced and temporally delayed sampling pulses. This principle is used in a cross-correlator characterizing optical pulses at 1053 nm, where a dynamic range higher than 60 dB is obtained over a temporal range larger than 200 ps. The dynamic range can be extended with standard optical-density filters and the temporal range extended with larger optics. (4) presents a novel focal-spot diagnostic developed for OMEGA EP that will be used to characterize on-shot focal spots to support high-quality laser-matter interaction experiments (p. 94). The complex fields in the region of the high-energy focus are calculated using high-resolution measurements of the main beam wavefront using the focal-spot diagnostic (FSD) located on the short-pulse diagnostic package and a careful calibration of the transfer wavefront between the FSD instrument and target chamber center. The concept of this calibration procedure is experimentally verified in the Multi-Terawatt (MTW) Laser System, which serves as a development platform for OMEGA EP. A technique based on phase retrieval is employed for the transfer-wavefront calibration since the OMEGA EP infrastructure cannot be replicated in the MTW laser; however, this approach also shows promise as an alternative method for OMEGA EP. (5) report on a systematic study to improve the laser-damage resistance of multilayer high-reflector coatings for use at 351 nm on the OMEGA EP Laser System (p. 103). A series of ha

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗