Search NASA⌕ Search

SEARCH · Search NASA

Results for “errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Quantum error correction with degenerate codes for correlated noise

We introduce a quantum packing bound on the minimal resources required by nondegenerate error-correction codes for any kind of noise. We prove that degenerate codes can outperform nondegenerate ones in the presence of correlated noise, by exhibiting examples where the quantum packing bound is violated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Minimum error discrimination between similarity-transformed quantum states

Using the well-known necessary and sufficient conditions for minimum error discrimination (MED), we extract an equivalent form for the MED conditions. In fact, by replacing the inequalities corresponding to the MED conditions with an equivalent but more suitable and convenient identity, the problem of mixed state discrimination with optimal success probability is solved. Moreover, we show that the mentioned optimality conditions can be viewed as a Helstrom family of ensembles under some circumstances. Using the given identity, MED between N similarity transformed equiprobable quantum states is investigated. In the case that the unitary operators are generating a set of irreducible representation, the optimal set of measurements and corresponding maximum success probability of discrimination can be determined precisely. In particular, it is shown that for equiprobable pure states, the optimal measurement strategy is the square-root measurement (SRM), whereas for the mixed states, SRM is not optimal. In the case that the unitary operators are reducible, there is no closed-form formula in the general case, but the procedure can be applied in each case in accordance to that case. Finally, we give the maximum success probability of optimal discrimination for some important examples of mixed quantum states, such as generalized Bloch sphere m-qubit states, spin-j states, particular nonsymmetric qudit states, etc.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum error correction of continuous-variable states against Gaussian noise

We describe a continuous-variable error correction protocol that can correct the Gaussian noise induced by linear loss on Gaussian states. The protocol can be implemented using linear optics and photon counting. We explore the theoretical bounds of the protocol as well as the expected performance given current knowledge and technology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tripartite entanglement in qudit stabilizer states and application in quantum error correction

Consider a stabilizer state on n qudits, each of dimension D with D being a prime or squarefree integer, divided into three mutually disjoint sets or parts. Generalizing a result of Bravyi et al.[J. Math. Phys. 47, 062106 (2006)] for qubits (D=2), we show that up to local unitaries, the three parts of the state can be written as tensor product of unentangled signle-qudit states, maximally entangled Einstein-Podolsky-Rosen (EPR) pairs, and tripartite Greenberger-Horne-Zeilinger (GHZ) states. We employ this result to obtain a complete characterization of the properties of a class of channels associated with stabilizer error-correcting codes, along with their complementary channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of possible systematic errors in the Oslo method

In this work, we have reviewed the Oslo method, which enables the simultaneous extraction of the level density and {gamma}-ray transmission coefficient from a set of particle-{gamma} coincidence data. Possible errors and uncertainties have been investigated. Typical data sets from various mass regions as well as simulated data have been tested against the assumptions behind the data analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Redundancy and Error Resilience in Boolean Networks

We consider the effect of noise in sparse Boolean networks with redundant functions. We show that they always exhibit a nonzero error level, and the dynamics undergoes a phase transition from nonergodicity to ergodicity, as a function of noise, after which the system is no longer capable of preserving a memory of its initial state. We obtain upper bounds on the critical value of noise for networks of different sparsity.

97 MATHEMATICS AND COMPUTING↗

Virtualized Logical Qubits: A 2.5D Architecture for Error-Corrected Quantum Computing

Current, near-term quantum devices have shown great progress in the last several years culminating recently with a demonstration of quantum supremacy. In the medium-term, however, quantum machines will need to transition to greater reliability through error correction, likely through promising techniques like surface codes which are well suited for near-term devices with limited qubit connectivity. We discover quantum memory, particularly resonant cavities with transmon qubits arranged in a 2.5D architecture, can efficiently implement surface codes with substantial hardware savings and performance/fidelity gains. Specifically, we virtualize logical qubits by storing them in layers of qubit memories connected to each transmon. Surprisingly, distributing each logical qubit across many memories has a minimal impact on fault tolerance and results in substantially more efficient operations. Our design permits fast transversal application of CNOT operations between logical qubits sharing the same physical address (same set of cavities) which are 6x faster than standard lattice surgery CNOTs. We develop a novel embedding which saves approximately 10x in transmons with another 2x savings from an additional optimization for compactness. Although qubit virtualization pays a 10x penalty in serialization, advantages in the transversal CNOT and in area efficiency result in fault-tolerance and performance comparable to conventional 2D transmon-only architectures. Our simulations show our system can achieve fault tolerance comparable to conventional two-dimensional grids while saving substantial hardware. Furthermore, our architecture can produce magic states at 1.22x the baseline rate given a fixed number of transmon qubits. Here, this is a critical benchmark for future fault-tolerant quantum computers as magic states are essential and machines will spend the majority of their resources continuously producing them. This architecture substantially reduces the hardware requirements for fault-tolerant quantum computing and puts within reach a proof-of-concept experimental demonstration of around 10 logical qubits, requiring only 11 transmons and 9 attached cavities in total.

quantum computing↗

Correcting incompatible DN values and geometric errors in nighttime lights time series images

The Defense Meteorological Satellite Program’s Operational Linescan System (DMSP-OLS) nighttime lights imagery has proven to be a powerful remote sensing tool to monitor urbanization and assess socioeconomic activities at large scales. However, the existence of incompatible digital number (DN) values and geometric errors severely limit application of nighttime light image data on multi-year quantitative research. In this study we extend and improve previous studies on inter-calibrating nighttime lights image data to obtain more compatible and reliable nighttime lights time series (NLT) image data for China and the United States (US) through four steps: inter-calibration, geometric correction, steady increase adjustment, and population data correction. We then use gross domestic product (GDP) data to test the processed NLT image data indirectly and find that sum light (summed DN value of pixels in a nighttime light image) maintains apparent increase trends with relatively large GDP growth rates but does not increase or decrease with relatively small GDP growth rates. As nighttime light is a sensitive indicator for economic activity, the temporally consistent trends between sum light and GDP growth rate imply that brightness of nighttime lights on the ground is correctly represented by the processed NLT image data. Finally, through analyzing the corrected NLT image data from 1992 to 2008, we find that China experienced apparent nighttime lights development in 1992-1997 and 2001-2008 respectively and the US suffered from nighttime lights decay in large areas after 2001.

47 OTHER INSTRUMENTATION↗

An effective correction algorithm for off-axis portal dosimetry errors

Portal dosimetric images acquired for IMRT pretreatment verification show dose errors of up to 15% near the detector edges as compared to dose predictions calculated by a treatment planning system for these off-axis regions. A method is proposed to account for these off-axis effects by precisely correcting the off-axis output factors, which calibrate the imager for absolute dose. Using this method, agreement between the predicted and the measured doses improves by up to 15% for fields near the detector edges, resulting in passing rate improvements of as much as 60% for gamma evaluation of 3 mm, 3% within the collimator jaws.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-164: Estimation of DVH Variation for PTV Due to Interfraction Organ Motion in Prostate VMAT Using Gaussian Error Function

Purpose: We developed a method to predict the change of DVH for PTV due to interfraction organ motion in prostate VMAT without repeating the CT scan and treatment planning. The method is based on a pre-calculated patient database with DVH curves of PTV modelled by the Gaussian error function (GEF). Methods: For a group of 30 patients with different prostate sizes, their VMAT plans were recalculated by shifting their PTVs 1 cm with 10 increments in the anterior-posterior, left-right and superior-inferior directions. The DVH curve of PTV in each replan was then fitted by the GEF to determine parameters describing the shape of curve. Information of parameters, varying with the DVH change due to prostate motion for different prostate sizes, was analyzed and stored in a database of a program written by MATLAB. Results: To predict a new DVH for PTV due to prostate interfraction motion, prostate size and shift distance with direction were input to the program. Parameters modelling the DVH for PTV were determined based on the pre-calculated patient dataset. From the new parameters, DVH curves of PTVs with and without considering the prostate motion were plotted for comparison. The program was verified with different prostate cases involving interfraction prostate shifts and replans. Conclusion: Variation of DVH for PTV in prostate VMAT can be predicted using a pre-calculated patient database with DVH curve fitting. The computing time is fast because CT rescan and replan are not required. This quick DVH estimation can help radiation staff to determine if the changed PTV coverage due to prostate shift is tolerable in the treatment. However, it should be noted that the program can only consider prostate interfraction motions along three axes, and is restricted to prostate VMAT plan using the same plan script in the treatment planning system.

60 APPLIED LIFE SCIENCES↗

SU-E-T-385: Evaluation of DVH Change for PTV Due to Patient Weight Loss in Prostate VMAT Using Gaussian Error Function

Purpose: We proposed a method to predict the change of dose-volume histogram (DVH) for PTV due to patient weight loss in prostate volumetric modulated arc therapy (VMAT). This method is based on a pre-calculated patient dataset and DVH curve fitting using the Gaussian error function (GEF). Methods: Pre-calculated dose-volume data from patients having weight loss in prostate VMAT was employed to predict the change of PTV coverage due to reduced depth in external contour. The effect of patient weight loss in treatment was described by a prostate dose-volume factor (PDVF), which was evaluated by the prostate PTV. Along with the PDVF, the GEF was used to fit into the DVH curve for the PTV. To predict a new DVH due to weight loss, parameters from the GEF describing the shape of DVH curve were determined. Since the parameters were related to the PDVF as per the specific reduced depth, we could first predict the PDVF at a reduced depth based on the prostate size from the pre-calculated dataset. Then parameters of the GEF could be determined from the PDVF to plot the new DVH for the PTV corresponding to the reduced depth. Results: A MATLAB program was built basing on the patient dataset with different prostate sizes. We input data of the prostate size and reduced depth of the patient into the program. The program then calculated the PDVF and DVH for the PTV considering the patient weight loss. The program was verified by different patient cases with various reduced depths. Conclusion: Our method can estimate the change of DVH for the PTV due to patient weight loss quickly without CT rescan and replan. This would help the radiation staff to predict the change of PTV coverage, when patient’s external contour reduced in prostate VMAT.

60 APPLIED LIFE SCIENCES↗

Multivariate analysis for the estimation of target localization errors in fiducial marker-based radiotherapy

Purpose: To assess the target localization error (TLE) in terms of the distance between the target and the localization point estimated from the surrogates (|TMD|), the average of respiratory motion for the surrogates and the target (|aRM|), and the number of fiducial markers used for estimating the target (n). Methods: This study enrolled 17 lung cancer patients who subsequently underwent four fractions of real-time tumor tracking irradiation. Four or five fiducial markers were implanted around the lung tumor. The three-dimensional (3D) distance between the tumor and markers was at maximum 58.7 mm. One of the markers was used as the target (P{sub t}), and those markers with a 3D |TMD{sub n}| ≤ 58.7 mm at end-exhalation were then selected. The estimated target position (P{sub e}) was calculated from a localization point consisting of one to three markers except P{sub t}. Respiratory motion for P{sub t} and P{sub e} was defined as the root mean square of each displacement, and |aRM| was calculated from the mean value. TLE was defined as the root mean square of each difference between P{sub t} and P{sub e} during the monitoring of each fraction. These procedures were performed repeatedly using the remaining markers. To provide the best guidance on the answer with n and |TMD|, fiducial markers with a 3D |aRM ≥ 10 mm were selected. Finally, a total of 205, 282, and 76 TLEs that fulfilled the 3D |TMD| and 3D |aRM| criteria were obtained for n = 1, 2, and 3, respectively. Multiple regression analysis (MRA) was used to evaluate TLE as a function of |TMD| and |aRM| in each n. Results: |TMD| for n = 1 was larger than that for n = 3. Moreover, |aRM| was almost constant for all n, indicating a similar scale for the marker’s motion near the lung tumor. MRA showed that |aRM| in the left–right direction was the major cause of TLE; however, the contribution made little difference to the 3D TLE because of the small amount of motion in the left–right direction. The TLE calculated from the MRA ({sup MRA}TLE) increased as |TMD| and |aRM| increased and adversely decreased with each increment of n. The median 3D {sup MRA}TLE was 2.0 mm (range, 0.6–4.3 mm) for n = 1, 1.8 mm (range, 0.4–4.0 mm) for n = 2, and 1.6 mm (range, 0.3–3.7 mm) for n = 3. Although statistical significance between n = 1 and n = 3 was observed in all directions, the absolute average difference and the standard deviation of the {sup MRA}TLE between n = 1 and n = 3 were 0.5 and 0.2 mm, respectively. Conclusions: A large |TMD| and |aRM| increased the differences in TLE between each n; however, the difference in 3D {sup MRA}TLEs was, at most, 0.6 mm. Thus, the authors conclude that it is acceptable to continue fiducial marker-based radiotherapy as long as |TMD| is maintained at ≤58.7 mm for a 3D |aRM| ≥ 10 mm.

60 APPLIED LIFE SCIENCES↗

SU-C-BRB-06: Dosimetric Impact of Breast Contour Reconstruction Errors in GammaPod Stereotactic Radiotherapy

Purpose: The first GammaPod™ unit, a dedicated prone stereotactic treatment device for early stage breast cancer, has been installed and commissioned at University of Maryland School of Medicine. The objective of this study was to investigate potential dosimetric impact of inaccurate breast contour. Methods: In GammaPod treatments, patient’s beast is immobilized by a breast cup device (BCID) throughout the entire same-day imaging and treatment procedure. 28 different BICD sizes are available to accommodate patients with varying breast sizes. A mild suction helps breast tissue to conform to the shape of the cup with selected size. In treatment planning, dose calculation utilizes previously calculated dose distributions for available cup geometry rather than the breast shape from CT image. Patient CT images with breast cups indicate minor geometric discrepancy between the matched shape of the cup and the breast contour, i.e., the contour size is larger or smaller. In order to investigate the dosimetric impact of these discrepancies, we simulated such discrepancies and reassessed the dose to target as well as skin. Results: In vicinity of skin, hot/cold spots were found when matched cup size was smaller/larger than patient’s breast after comparing the corrected dose profiles from Monte Carlo simulation with the planned dose from TPS. The overdosing/underdosing of target could yield point dose differences as large as 5% due to these setup errors (D95 changes within 2.5%). Maximal skin dose was overestimated/underestimated up to 25%/45% when matched cup size was larger/smaller than real breast contour. Conclusion: The dosimetric evaluation suggests substantial underdosing/overdosing with inaccurate cup geometry during planning, which is acceptable for current clinical trial. Further studies are needed to evaluate such impact to treating small volume close to skin.

60 APPLIED LIFE SCIENCES↗

SU-G-BRC-15: The Potential Clinical Significance of Dose Mapping Error for Intra- Fraction Dose Mapping for Lung Cancer Patients

Purpose: To evaluate the dose-mapping error (DME) inherent to conventional dose-mapping algorithms as a function of dose-matrix resolution. Methods: As DME has been reported to be greatest where dose-gradients overlap tissue-density gradients, non-clinical 66 Gy IMRT plans were generated for 11 lung patients with the target edge defined as the maximum 3D density gradient on the 0% (end of inhale) breathing phase. Post-optimization, Beams were copied to 9 breathing phases. Monte Carlo dose computed (with 2*2*2 mm{sup 3} resolution) on all 10 breathing phases was deformably mapped to phase 0% using the Monte Carlo energy-transfer method with congruent mass-mapping (EMCM); an externally implemented tri-linear interpolation method with voxel sub-division; Pinnacle’s internal (tri-linear) method; and a post-processing energy-mass voxel-warping method (dTransform). All methods used the same base displacement-vector-field (or it’s pseudo-inverse as appropriate) for the dose mapping. Mapping was also performed at 4*4*4 mm{sup 3} by merging adjacent dose voxels. Results: Using EMCM as the reference standard, no clinically significant (>1 Gy) DMEs were found for the mean lung dose (MLD), lung V20Gy, or esophagus dose-volume indices, although MLD and V20Gy were statistically different (2*2*2 mm{sup 3}). Pinnacle-to-EMCM target D98% DMEs of 4.4 and 1.2 Gy were observed ( 2*2*2 mm{sup 3}). However dTransform, which like EMCM conserves integral dose, had DME >1 Gy for one case. The root mean square RMS of the DME for the tri-linear-to- EMCM methods was lower for the smaller voxel volume for the tumor 4D-D98%, lung V20Gy, and cord D1%. Conclusion: When tissue gradients overlap with dose gradients, organs-at-risk DME was statistically significant but not clinically significant. Target-D98%-DME was deemed clinically significant for 2/11 patients (2*2*2 mm{sup 3}). Since tri-linear RMS-DME between EMCM and tri-linear was reduced at 2*2*2 mm{sup 3}, use of this resolution is recommended for dose mapping. Interpolative dose methods are sufficiently accurate for the majority of cases. J.V. Siebers receives funding support from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-G-BRA-04: Simulation of Errors in Maximal Intensity Projection (MIP)-Based Lung Tumor Internal Target Volumes (ITV) Using Real-Time 2D MRI and Deformable Image Registration Based Lung Tumor Tracking

Purpose: To evaluate the effect of inter- and intra-fractional tumor motion on the error in four-dimensional computed tomography (4DCT) maximal intensity projection (MIP)–based lung tumor internal target volumes (ITV), using deformable image registration of real-time 2D-sagital cine-mode MRI acquired during lung SBRT treatments. Methods: Five lung tumor patients underwent free breathing SBRT treatment on the ViewRay, with dose prescribed to PTV (4DCT MIP-based ITV+3–6mm margin). Sagittal slice cine-MR images (3.5×3.5mm pixels) were acquired through the center of the tumor at 4 frames per second throughout the treatments (3–4 fractions of 21–32 minutes duration). Tumor GTVs were contoured on the first frame of the cine and tracked throughout the treatment using off-line optical-flow based deformable registration implemented on a GPU cluster. Pseudo-4DCT MIP-based ITVs were generated from MIPs of the deformed GTV contours limited to short segments of image data. All possible pseudo-4DCT MIP-based ITV volumes were generated with 1s resolution and compared to the ITV volume of the entire treatment course. Varying pseudo-4DCT durations from 10-50s were analyzed. Results: Tumors were covered in their entirety by PTV in the patients analysed here. However, pseudo-4DCT based ITV volumes were observed that were as small as 29% of the entire treatment-ITV, depending on breathing irregularity and the duration of pseudo-4DCT. With an increase in duration of pseudo-4DCT from 10–50s the minimum volume acquired from 95% of all pseudo-4DCTs increased from 62%–81% of the treatment ITV. Conclusion: A 4DCT MIP-based ITV offers a ‘snap-shot’ of breathing motion for the brief period of time the tumor is imaged on a specific day. Real time MRI over prolonged periods of time and over multiple treatment fractions shows that the accuracy of this snap-shot varies according to inter- and intra-fractional tumor motion. Further work is required to investigate the dosimetric effect of these results.

60 APPLIED LIFE SCIENCES↗

WE-D-204-02: Errors and Process Improvements in Radiation Therapy

Speakers in this session will present overview and details of a specific rotation or feature of their Medical Physics Residency Program that is particularly exceptional and noteworthy. The featured rotations include foundational topics executed with exceptional acumen and innovative educational rotations perhaps not commonly found in Medical Physics Residency Programs. A site-specific clinical rotation will be described, where the medical physics resident follows the physician and medical resident for two weeks into patient consultations, simulation sessions, target contouring sessions, planning meetings with dosimetry, patient follow up visits, and tumor boards, to gain insight into the thought processes of the radiation oncologist. An incident learning rotation will be described where the residents learns about and practices evaluating clinical errors and investigates process improvements for the clinic. The residency environment at a Canadian medical physics residency program will be described, where the training and interactions with radiation oncology residents is integrated. And the first month rotation will be described, where the medical physics resident rotates through the clinical areas including simulation, dosimetry, and treatment units, gaining an overview of the clinical flow and meeting all the clinical staff to begin the residency program. This session will be of particular interest to residency programs who are interested in adopting or adapting these curricular ideas into their programs and to residency candidates who want to learn about programs already employing innovative practices. Learning Objectives: To learn about exceptional and innovative clinical rotations or program features within existing Medical Physics Residency Programs. To understand how to adopt/adapt innovative curricular designs into your own Medical Physics Residency Program, if appropriate.

60 APPLIED LIFE SCIENCES↗

Statistical error of reactor calculations by the Monte Carlo method

Algorithms for calculating the statistical error with allowance for intergenerational correlations are described. The algorithms are constructed on the basis of statistical analysis of the results of computations by the Monte Carlo method. As a result, simple rules for choosing the parameters of the computational techniques, such as the number of simulated generations necessary for attaining the required accuracy and the number of first skipped generations, are elaborated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sources of the systematic errors in measurements of {sup 214}Po decay half-life time variations at the Baksan deep underground experiments

The design changes of the Baksan low-background TAU-1 and TAU-2 set-ups allowed to improve a sensitivity of {sup 214}Po half-life (τ) measurements up to the 2.5 × 10{sup −4} are described. Different possible sources of systematic errors influencing on the τ-value are studied. An annual variation of {sup 214}Po half-life time measurements with an amplitude of A = (6.9 ± 3) × 10{sup −4} and a phase of φ = 93 ± 10 days was found in a sequence of the week-collected τ-values obtained from the TAU-2 data sample with total duration of 480 days. 24 hours’ variation of the t-value measurements with an amplitude of A = (10.0 ± 2.6) × 10{sup −4} and phase of φ = 1 ± 0.5 hours was found in a solar day 1 hour step t-value sequence formed from the same data sample. It was found that the {sup 214}Po half-life averaged at 480 days is equal to 163.45 ± 0.04 μs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗