Search NASA⌕ Search

SEARCH · Search NASA

Results for “fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Astrophysical S factor for the {sup 15}N(p,{gamma}){sup 16}O reaction

The R-matrix approach has proved to be very useful in extrapolating the astrophysical factor down to astrophysically relevant energies, since the majority of measurements are not available in this region. However, such an approach has to be critically considered when no complete knowledge of the reaction model is available. To get reliable results in such cases one has to use all the available information from independent sources and, accordingly, fix or constrain variations of the parameters. In this paper we present a thorough R-matrix analysis of the {sup 15}N(p,{gamma}){sup 16}O reaction, which provides a path from the CN cycle to the CNO bi-cycle and CNO tri-cycle. The measured astrophysical factor for this reaction is dominated by resonant capture through two strong J{sup {pi}}=1{sup -} resonances at E{sub R}=312 and 962 keV and direct capture to the ground state. Recently, a new measurement of the astrophysical factor for the {sup 15}N(p,{gamma}){sup 16}O reaction has been published [P. J. LeBlanc et al., Phys. Rev. C 82, 055804 (2010)]. The analysis has been done using the R-matrix approach with unconstrained variation of all parameters including the asymptotic normalization coefficient (ANC). The best fit has been obtained for the square of the ANC C{sup 2}=539.2 fm{sup -1}, which exceeds the previously measured value by a factor of {approx_equal}3. Here we present a new R-matrix analysis of the Notre Dame-LUNA data with the fixed within the experimental uncertainties square of the ANC C{sup 2}=200.34 fm{sup -1}. Rather than varying the ANC we add the contribution from a background resonance that effectively takes into account contributions from higher levels. Altogether we present ten fits, seven unconstrained and three constrained. For the unconstrained fit with the boundary condition B{sub c}=S{sub c}(E{sub 2}), where E{sub 2} is the energy of the second level, we get S(0)=39.0{+-}1.1 keVb and normalized {chi}-tilde{sup 2}=1.84, i.e., the result which is similar to LeBlanc et al. From all our fits we get the range 33.1{<=}S(0){<=}40.1 keVb which overlaps with the result of LeBlanc et al. We address also the physical interpretation of the fitting parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of renormalon scheme and perturbative scale choices on determinations of the strong coupling from e + e − event shapes

We study the role of renormalon cancellation schemes and perturbative scale choices in extractions of the strong coupling constant α s ( m Z ) and the leading nonperturbative shift parameter Ω 1 from resummed predictions of the e + e − event shape thrust. We calculate the thrust distribution to N L 3 L ′ resummed accuracy in soft-collinear effective theory (SCET) matched to the fixed-order O ( α s 2 ) prediction, and perform a new high-statistics computation of the O ( α s 3 ) matching in , although we do not include the latter in our final α s fits due to some observed systematics that require further investigation. We are primarily interested in testing the phenomenological impact sourced from varying amongst three renormalon cancellation schemes and two sets of perturbative scale profile choices. We then perform a global fit to available data spanning center-of-mass energies between 35–207 GeV in each scenario. Relevant subsets of our results are consistent with prior SCET-based extractions of α s ( m Z ) , but we are also led to a number of novel observations. Notably, we find that the combined effect of altering the renormalon cancellation scheme and profile parameters can lead to few-percent-level impacts on the extracted values in the α s − Ω 1 plane, indicating a potentially important systematic theory uncertainty that should be accounted for. We also observe that fits performed over windows dominated by dijet events are typically of a higher quality than those that extend into the far tails of the distributions, possibly motivating future fits focused more heavily in this region. Finally, we discuss how different estimates of the three-loop soft matching coefficient c S ˜ 3 can also lead to measurable changes in the fitted { α s , Ω 1 } values. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sterile neutrino oscillations after first MiniBooNE results

In view of the recent results from the MiniBooNE experiment we revisit the global neutrino oscillation fit to short-baseline neutrino data by adding one or two sterile neutrinos with eV-scale masses to the three standard model neutrinos, and for the first time we consider also the global fit with three sterile neutrinos. Four-neutrino oscillations of the (3+1) type have been only marginally allowed before the recent MiniBooNE results, and become even more disfavored with the new data (at the level of 4{sigma}). In the framework of so-called (3+2) five-neutrino mass schemes we find severe tension between appearance and disappearance experiments at the level of more than 3{sigma}, and hence no satisfactory fit to the global data is possible in (3+2) schemes. This tension remains also when a third sterile neutrino is added, and the quality of the global fit does not improve significantly in a (3+3) scheme. It should be noted, however, that in models with more than one sterile neutrino the MiniBooNE results are in perfect agreement with the appearance evidence reported by the LSND Collaboration, thanks to the possibility of CP violation available in such oscillation schemes. Furthermore, if disappearance data are not taken into account (3+2) oscillations provide an excellent fit to the full MiniBooNE spectrum including the event excess at low energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bright high z SnIa: A challenge for {lambda}CDM

It has recently been pointed out by Kowalski et. al.[Astrophys. J. 686, 749 (2008).] that there is 'an unexpected brightness of the SnIa data at z>1'. We quantify this statement by constructing a new statistic which is applicable directly on the type Ia supernova (SnIa) distance moduli. This statistic is designed to pick up systematic brightness trends of SnIa data points with respect to a best fit cosmological model at high redshifts. It is based on binning the normalized differences between the SnIa distance moduli and the corresponding best fit values in the context of a specific cosmological model (e.g. {lambda}CDM). These differences are normalized by the standard errors of the observed distance moduli. We then focus on the highest redshift bin and extend its size toward lower redshifts until the binned normalized difference (BND) changes sign (crosses 0) at a redshift z{sub c} (bin size N{sub c}). The bin size N{sub c} of this crossing (the statistical variable) is then compared with the corresponding crossing bin size N{sub mc} for Monte Carlo data realizations based on the best fit model. We find that the crossing bin size N{sub c} obtained from the Union08 and Gold06 data with respect to the best fit {lambda}CDM model is anomalously large compared to N{sub mc} of the corresponding Monte Carlo data sets obtained from the best fit {lambda}CDM in each case. In particular, only 2.2% of the Monte Carlo {lambda}CDM data sets are consistent with the Gold06 value of N{sub c} while the corresponding probability for the Union08 value of N{sub c} is 5.3%. Thus, according to this statistic, the probability that the high redshift brightness bias of the Union08 and Gold06 data sets is realized in the context of a (w{sub 0},w{sub 1})=(-1,0) model ({lambda}CDM cosmology) is less than 6%. The corresponding realization probability in the context of a (w{sub 0},w{sub 1})=(-1.4,2) model is more than 30% for both the Union08 and the Gold06 data sets indicating a much better consistency for this model with respect to the BND statistic.

79 ASTRONOMY AND ASTROPHYSICS↗

Short-baseline electron neutrino disappearance, tritium beta decay, and neutrinoless double-beta decay

We consider the interpretation of the MiniBooNE low-energy anomaly and the gallium radioactive source experiments anomaly in terms of short-baseline electron neutrino disappearance in the framework of 3+1 four-neutrino mixing schemes. The separate fits of MiniBooNE and gallium data are highly compatible, with close best-fit values of the effective oscillation parameters {Delta}m{sup 2} and sin{sup 2}2{theta}. The combined fit gives {Delta}m{sup 2}(greater-or-similar sign)0.1 eV{sup 2} and 0.11(less-or-similar sign)sin{sup 2}2{theta}(less-or-similar sign)0.48 at 2{sigma}. We consider also the data of the Bugey and Chooz reactor antineutrino oscillation experiments and the limits on the effective electron antineutrino mass in {beta} decay obtained in the Mainz and Troitsk tritium experiments. The fit of the data of these experiments limits the value of sin{sup 2}2{theta} below 0.10 at 2{sigma}. Considering the tension between the neutrino MiniBooNE and gallium data and the antineutrino reactor and tritium data as a statistical fluctuation, we perform a combined fit which gives {Delta}m{sup 2}{approx_equal}2 eV and 0.01(less-or-similar sign)sin{sup 2}2{theta}(less-or-similar sign)0.13 at 2{sigma}. Assuming a hierarchy of masses m{sub 1}, m{sub 2}, m{sub 3}<<m{sub 4}, the predicted contributions of m{sub 4} to the effective neutrino masses in {beta} decay and neutrinoless double-{beta} decay are, respectively, between about 0.06 and 0.49 and between about 0.003 and 0.07 eV at 2{sigma}. We also consider the possibility of reconciling the tension between the neutrino MiniBooNE and gallium data and the antineutrino reactor and tritium data with different mixings in the neutrino and antineutrino sectors. We find a 2.6{sigma} indication of a mixing angle asymmetry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pati-Salam SUSY GUT with Yukawa unification

Prior studies of a three family Yukawa unified supersymmetric grand unified theory (SUSY GUT) with SO(10) or Pati-Salam (PS) gauge symmetry proposed by Raby and students show that this model is able to fit low energy and inflation observables. Yet, the fit to low energy observables is not great especially for $\sin2\beta$, and up and down quark masses. In this paper, we show that by choosing PS as the gauge group and modifying the Yukawa sector, the low energy fit improves significantly while other qualities of the model are maintained. In particular, the lightest SUSY particle is the neutralino with mass of order 300 - 500 GeV, the lightest stop and sbottom have mass of order 3 - 5 TeV and the CP odd Higgs mass is of order 5 - 6 TeV, so we are in the decoupling limit for the light Higgs. In addition, we reinterpret gluino simplified model analyses by the ATLAS and CMS collaborations and find that the most stringent gluino mass bound for our model is $M_{\tilde{g}}\sim1.9\,\text{TeV}$. The current best fit point, consistent with this bound, with gluino mass $M_{\tilde{g}}=1.9\,\text{TeV}$ has $\chi^2/\text{dof}\approx1.12$, compared to the best fit point of the previous model with $\chi^2/\text{dof}=1.90$. We find that predictions for the electric dipole moment of the electron, the branching ratio $BR(\mu \rightarrow e \gamma)$ and the CP violating angle in the lepton sector, $\sin\delta$, are affected significantly as compared to previous results. In conclusion, we are unable to rule out this model or place an upper bound on gluino mass accessible by this run of the LHC because the $\chi^2/\text{dof}$ of this model is well below $2\sigma$ even for a gluino mass as high as 2.7 TeV. On the bright side, this means that this model is still viable and we might find low energy SUSY particles in the near future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physically interpretable approximations of many-body spectral functions

The rational function approximation provides a natural and interpretable representation of response functions such as the many-body spectral functions. We apply the vector fitting (VFIT) algorithm to fit a variety of spectral functions calculated from the Holstein model of electron-phonon interactions. We show that the resulting rational functions are highly efficient in their fitting of sharp features in the spectral functions, and could provide a means to infer physically relevant information from a spectral data set. The position of the peaks in the approximated spectral function are determined by the location of poles in the complex plane. Additionally, we developed a variant of VFIT that incorporates regularization to improve the quality of fits. With this procedure, we demonstrate it is possible to achieve accurate spectral function fits that vary smoothly as a function of physical conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MapsTorch : automatic differentiation for X-ray fluorescence data analysis

X-ray fluorescence (XRF) is a popular spectroscopy technique for elemental analysis. Spectrum fitting and parameter tuning are at the core of XRF analysis and are conventionally manually intensive, especially for synchrotron experiments involving large amounts of diverse samples. This work introduces the automatic differentiation (AD) technique to XRF and an open-source package called MapsTorch. By transforming an analytical model of the XRF spectrum into a differentiable computation graph with AD, MapsTorch enables robust optimization of parameters and elemental intensities. We evaluate MapsTorch by conducting computational experiments on a large number of historical synchrotron XRF datasets and compare its performance with the currently practiced fitting tool NLopt. The results show that MapsTorch consistently achieves high-quality fits and often leads to better fitting quality than NLopt, particularly in tasks such as initial spectrum fitting and elemental intensity refinement. The robust performance of MapsTorch paves the way for developing automated and high-throughput XRF data analysis workflows to handle the increasing data volumes expected from next-generation synchrotron facilities.

X-ray fluorescence↗

Optimal Pulse Processing, Pile-Up Decomposition, and Applications of Silicon Drift Detectors at LCLS

Silicon drift detectors (SDDs) revolutionized spectroscopy in fields as diverse as geology and dentistry. For a subset of experiments at ultrafast, X-ray free-electron lasers (FELs), SDDs can make substantial contributions. Often the unknown spectrum is interesting, carrying science data, or the background measurement is useful to identify unexpected signals. Many measurements involve only several discrete photon energies known a priori, allowing single-event decomposition of pile-up and spectroscopic photon counting. We designed a pulse function and demonstrated that the signal amplitude (i.e., proportional to the detected energy and obtained from fitting with the pulse function), rise time, and pulse height are interrelated, and at short peaking times, the pulse height and pulse area are not optimal estimators for detected energy; instead, the signal amplitude and rise time are obtained for each pulse by fitting, thus removing the need for pulse shaping. By avoiding pulse shaping, rise times of tens of nanoseconds resulted in reduced pulse pile-up and allowed decomposition of remaining pulse pile-up at photon separation times down to hundreds of nanoseconds while yielding time-of-arrival information with the precision of 10 ns. Waveform fitting yields simultaneously high energy resolution and high counting rates (two orders of magnitude higher than current digital pulse processors). At pulsed sources or high photon rates, photon pile-up still occurs. We showed that pile-up spectrum fitting is relatively simple and preferable to pile-up spectrum deconvolution. We then developed a photon pile-up statistical model for constant intensity sources, extended it to variable intensity sources (typical for FELs), and used it to fit a complex pileup spectrum. We subsequently developed a Bayesian pile-up decomposition method that allows decomposing pile-up of single events with up to six photons from six monochromatic lines with 99% accuracy. The usefulness of SDDs will continue into the X-ray FEL era of science. Their successors, the ePixS hybrid pixel detectors, already offer hundreds of pixels, each with a similar performance to an SDD, in a compact, robust and affordable package.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physical Activity and School Absenteeism Due to Illness in Adolescents

ABSTRACT BACKGROUND Knowledge about the beneficial role of physical activity (PA) for health and school performance is growing. Studies investigating the link between PA and school absenteeism due to illness are lacking. Therefore, we investigated associations between habitual PA and school absenteeism due to illness in adolescents and explored whether mental health and cardiovascular fitness mediated this association. METHODS We studied 328 students in grades 7 and 9 (mean age 13.8 years; 49% boys). The PA was measured objectively by an ActivPAL3™ accelerometer attached on the thigh during 1 full week (24 hours/day). Depressive symptoms and self‐esteem were self‐reported by the Center for Epidemiologic Studies Depression Scale (CES‐D) and Rosenberg Self‐Esteem Scale, respectively, and included as a proxy for mental health in the analyses. Cardiovascular fitness was measured by the 20‐m shuttle‐run test. School absenteeism due to illness data was provided by the school administration. RESULTS The PA was not significantly associated with school absenteeism, though there was an indirect association between PA and school absenteeism by cardiovascular fitness. CONCLUSIONS Cardiovascular fitness mediates the association between PA and school absenteeism due to illness. Thus, cardiovascular fitness of students should be improved to reduce school absenteeism due to illness.

de Groot, Renate↗

Operating characteristics predicted by models for diagnostic tasks involving lesion localization

In 1996 Swensson published an observer model that predicted receiver operating characteristic (ROC), localization ROC (LROC), free-response ROC (FROC) and alternative FROC (AFROC) curves, thereby achieving ''unification'' of different observer performance paradigms. More recently a model termed initial detection and candidate analysis (IDCA) has been proposed for fitting computer aided detection (CAD) generated FROC data, and recently a search model for human observer FROC data has been proposed. The purpose of this study was to derive IDCA and the search model based expressions for operating characteristics, and to compare the predictions to the Swensson model. For three out of four mammography CAD data sets all models yielded good fits in the high-confidence region, i.e., near the lower end of the plots. The search model and IDCA tended to better fit the data in the low-confidence region, i.e., near the upper end of the plots, particularly for FROC curves for which the Swensson model predictions departed markedly from the data. For one data set none of the models yielded satisfactory fits. A unique characteristic of search model and IDCA predicted operating characteristics is that the operating point is not allowed to move continuously to the lowest confidence limit of the corresponding Swensson model curves. This prediction is actually observed in the CAD raw data and it is the primary reason for the poor FROC fits of the Swensson model in the low-confidence region.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiochromic film calibration for low-energy seed brachytherapy dose measurement

Purpose: Radiochromic film dosimetry is typically performed for high energy photons and moderate doses characterizing external beam radiotherapy (XRT). The purpose of this study was to investigate the accuracy of previously established film calibration procedures used in XRT when applied to low-energy, seed-based brachytherapy at higher doses, and to determine necessary modifications to achieve similar accuracy in absolute dose measurements. Methods: Gafchromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 75 kVp, 200 kVp, 6 MV, and (∼28 keV) I-125 photon sources. For the latter irradiations a custom phantom was built to hold a single I-125 seed. Film pieces were scanned with an Epson 10000XL flatbed scanner and the resulting 48-bit RGB TIFF images were analyzed using both FilmQA Pro software andMATLAB. Calibration curves relating dose and optical density via a rational functional form for all three color channels at each irradiation energy were determined with and without the inclusion of uncertainties in the measured optical densities and dose values. The accuracy of calibration curve variations obtained using piecewise fitting, a reduced film measurement area for I-125 irradiation, and a reduced number of dose levels was also investigated. The energy dependence of the film lot used was also analyzed by calculating normalized optical density values. Results: Slight differences were found in the resulting calibration curves for the various fitting methods used. The accuracy of the calibration curves was found to improve at low doses and worsen at high doses when including uncertainties in optical densities and doses, which may better represent the variability that could be seen in film optical density measurements. When exposing the films to doses > 8 Gy, two-segment piecewise fitting was found to be necessary to achieve similar accuracies in absolute dose measurements as when using smaller dose ranges. When reducing the film measurement area for the I-125 irradiations, the accuracy of the calibration curve was degraded due to the presence of localized film heterogeneities. No degradation in the calibration curves was found when reducing the number of calibration points down to only 4, but with piecewise fitting, 6 calibration points as well as a blank film are required. Variations due to photon energy in film optical density of up to 3% were found above doses of 2 Gy. Conclusions: A modified procedure for performing EBT3 film calibration was established for use with low-energy brachytherapy seeds and high dose exposures. The energy dependence between 6 MV and I-125 photons is significant such that film calibrations should be done with an appropriately low-energy source when performing low-energy brachytherapy dose measurements. Two-segment piecewise fitting with the inclusion of errors in measured optical density as well as dose was found to result in the most accurate calibration curves. Above doses of 1 Gy, absolute dose measurements can be made with an accuracy of 1.6% for 6 MV beams and 5.7% for I-125 seed exposures if using the I-125 source for calibration, or 2.3% if using the 75 kVp photon beam for calibration.

07 ISOTOPE AND RADIATION SOURCES↗

SU-C-9A-04: Alternative Analytic Solution to the Paralyzable Detector Model to Calculate Deadtime and Deadtime Loss

Purpose: Some common methods to solve for deadtime are (1) dual-source method, which assumes two equal activities; (2) model fitting, which requires multiple acquisitions as source decays; and (3) lossless model, which assumes no deadtime loss at low count rates. We propose a new analytic alternative solution to calculate deadtime for paralyzable gamma camera. Methods: Deadtime T can be calculated analytically from two distinct observed count rates M1 and M2 when the ratio of the true count rates alpha=N2/N1 is known. Alpha can be measured as a ratio of two measured activities using dose calibrators or via radioactive decay. Knowledge of alpha creates a system with 2 equations and 2 unknowns, i.e., T and N1. To verify the validity of the proposed method, projections of a non-uniform phantom (4GBq 99mTc) were acquired in using Siemens SymbiaS multiple times over 48 hours. Each projection has >100kcts. The deadtime for each projection was calculated by fitting the data to a paralyzable model and also by using the proposed 2-acquisition method. The two estimates of deadtime were compared using the Bland-Altmann method. In addition, the dependency of uncertainty in T on uncertainty in alpha was investigated for several imaging conditions. Results: The results strongly suggest that the 2-acquisition method is equivalent to the fitting method. The Bland-Altman analysis yielded mean difference in deadtime estimate of ∼0.076us (95%CI: -0.049us, 0.103us) between the 2-acquisition and model fitting methods. The 95% limits of agreement were calculated to be -0.104 to 0.256us. The uncertainty in deadtime calculated using the proposed method is highly dependent on the uncertainty in the ratio alpha. Conclusion: The 2-acquisition method was found to be equivalent to the parameter fitting method. The proposed method offers a simpler and more practical way to analytically solve for a paralyzable detector deadtime, especially during physics testing.

07 ISOTOPE AND RADIATION SOURCES↗

WE-G-18C-09: Separating Perfusion and Diffusion Components From Diffusion Weighted MRI of Rectum Tumors Based On Intravoxel Incoherent Motion (IVIM) Analysis

Purpose: Pseudodiffusion arises from the microcirculation of blood in the randomly oriented capillary network and contributes to the signal decay acquired using a multi-b value diffusion weighted (DW)-MRI sequence. This effect is more significant at low b-values and should be properly accounted for in apparent diffusion coefficient (ADC) calculations. The purpose of this study was to separate perfusion and diffusion component based on a biexponential and a segmented monoexponential model using IVIM analysis Methods. The signal attenuation is modeled as S(b) = S0[(1−f)exp(−bD) + fexp(−bD*)]. Fitting the biexponetial decay leads to the quantification of D, the true diffusion coefficient, D*, the pseudodiffusion coefficient, and f, the perfusion fraction. A nonlinear least squares fit and two segmented monoexponential models were used to derive the values for D, D*,‘and f. In the segmented approach b = 200 s/mm{sup 2} was used as the cut-off value for calculation of D. DW-MRI's of a rectum cancer patient were acquired before chemotherapy, before radiation therapy (RT), and 4 weeks into RT and were investigated as an example case. Results: Mean ADC for the tumor drawn on the DWI cases was 0.93, 1.0 and 1.13 10{sup −3}×mm{sup 2}/s before chemotherapy, before RT and 4 weeks into RT. The mean (D.10{sup −3} × mm{sup 2}/s, D* 10{sup −3} × mm{sup 2}/s, and f %) based on biexponential fit was (0.67, 18.6, and 27.2%), (0.72, 17.7, and 28.9%) and (0.83,15.1, and 30.7%) at these time points. The mean (D, D* f) based on segmented fit was (0.72, 10.5, and 12.1%), (0.72, 8.2, and 17.4%) and (.82, 8.1, 16.5%) Conclusion: ADC values are typically higher than true diffusion coefficients. For tumors with significant perfusion effect, ADC should be analyzed at higher b-values or separated from the perfusion component. Biexponential fit overestimates the perfusion fraction because of increased sensitivity to noise at low b-values.

60 APPLIED LIFE SCIENCES↗

TH-E-BRF-09: Gaussian Mixture Model Analysis of Radiation-Induced Parotid-Gland Injury: An Ultrasound Study of Acute and Late Xerostomia in Head-And-Neck Radiotherapy

Purpose: Xerostomia (dry mouth), secondary to parotid-gland injury, is a distressing side-effect in head-and-neck radiotherapy (RT). This study's purpose is to develop a novel ultrasound technique to quantitatively evaluate post-RT parotid-gland injury. Methods: Recent ultrasound studies have shown that healthy parotid glands exhibit homogeneous echotexture, whereas post-RT parotid glands are often heterogeneous, with multiple hypoechoic (inflammation) or hyperechoic (fibrosis) regions. We propose to use a Gaussian mixture model to analyze the ultrasonic echo-histogram of the parotid glands. An IRB-approved clinical study was conducted: (1) control-group: 13 healthy-volunteers, served as the control; (2) acutetoxicity group − 20 patients (mean age: 62.5 ± 8.9 years, follow-up: 2.0±0.8 months); and (3) late-toxicity group − 18 patients (mean age: 60.7 ± 7.3 years, follow-up: 20.1±10.4 months). All patients experienced RTOG grade 1 or 2 salivary-gland toxicity. Each participant underwent an ultrasound scan (10 MHz) of the bilateral parotid glands. An echo-intensity histogram was derived for each parotid and a Gaussian mixture model was used to fit the histogram using expectation maximization (EM) algorithm. The quality of the fitting was evaluated with the R-squared value. Results: (1) Controlgroup: all parotid glands fitted well with one Gaussian component, with a mean intensity of 79.8±4.9 (R-squared>0.96). (2) Acute-toxicity group: 37 of the 40 post-RT parotid glands fitted well with two Gaussian components, with a mean intensity of 42.9±7.4, 73.3±12.2 (R-squared>0.95). (3) Latetoxicity group: 32 of the 36 post-RT parotid fitted well with 3 Gaussian components, with mean intensities of 49.7±7.6, 77.2±8.7, and 118.6±11.8 (R-squared>0.98). Conclusion: RT-associated parotid-gland injury is common in head-and-neck RT, but challenging to assess. This work has demonstrated that the Gaussian mixture model of the echo-histogram could quantify acute and late toxicity of the parotid glands. This study provides meaningful preliminary data from future observational and interventional clinical research.

60 APPLIED LIFE SCIENCES↗

Characterization of XR-RV3 GafChromic{sup ®} films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors

Purpose: To investigate the optimal use of XR-RV3 GafChromic{sup ®} films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. Methods: XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patient skin dose in interventional procedures. As film dosimetry can be associated with high uncertainty, this paper presents the EURADOS WG 12 initiative to carry out a comprehensive study of film characteristics with a multisite approach. The considered sources of uncertainties include scanner, film, and fitting-related errors. The work focused on studying film behavior with clinical high-dose-rate pulsed beams (previously unavailable in the literature) together with reference standard laboratory beams. Results: First, the performance analysis of six different scanner models has shown that scan uniformity perpendicular to the lamp motion axis and that long term stability are the main sources of scanner-related uncertainties. These could induce errors of up to 7% on the film readings unless regularly checked and corrected. Typically, scan uniformity correction matrices and reading normalization to the scanner-specific and daily background reading should be done. In addition, the analysis on multiple film batches has shown that XR-RV3 films have generally good uniformity within one batch (<1.5%), require 24 h to stabilize after the irradiation and their response is roughly independent of dose rate (<5%). However, XR-RV3 films showed large variations (up to 15%) with radiation quality both in standard laboratory and in clinical conditions. As such, and prior to conducting patient skin dose measurements, it is mandatory to choose the appropriate calibration beam quality depending on the characteristics of the x-ray systems that will be used clinically. In addition, yellow side film irradiations should be preferentially used since they showed a lower dependence on beam parameters compared to white side film irradiations. Finally, among the six different fit equations tested in this work, typically used third order polynomials and more rational and simplistic equations, of the form dose inversely proportional to pixel value, were both found to provide satisfactory results. Fitting-related uncertainty was clearly identified as a major contributor to the overall film dosimetry uncertainty with up to 40% error on the dose estimate. Conclusions: The overall uncertainty associated with the use of XR-RV3 films to determine skin dose in the interventional environment can realistically be estimated to be around 20% (k = 1). This uncertainty can be reduced to within 5% if carefully monitoring scanner, film, and fitting-related errors or it can easily increase to over 40% if minimal care is not taken. This work demonstrates the importance of appropriate calibration, reading, fitting, and other film-related and scan-related processes, which will help improve the accuracy of skin dose measurements in interventional procedures.

60 APPLIED LIFE SCIENCES↗

SU-E-T-598: Parametric Equation for Quick and Reliable Estimate of Stray Neutron Doses in Proton Therapy and Application for Intracranial Tumor Treatments

Purpose: Development of a parametric equation suitable for a daily use in routine clinic to provide estimates of stray neutron doses in proton therapy. Methods: Monte Carlo (MC) calculations using the UF-NCI 1-year-old phantom were exercised to determine the variation of stray neutron doses as a function of irradiation parameters while performing intracranial treatments. This was done by individually changing the proton beam energy, modulation width, collimator aperture and thickness, compensator thickness and the air gap size while their impact on neutron doses were put into a single equation. The variation of neutron doses with distance from the target volume was also included in it. Then, a first step consisted in establishing the fitting coefficients by using 221 learning data which were neutron absorbed doses obtained with MC simulations while a second step consisted in validating the final equation. Results: The variation of stray neutron doses with irradiation parameters were fitted with linear, polynomial, etc. model while a power-law model was used to fit the variation of stray neutron doses with the distance from the target volume. The parametric equation fitted well MC simulations while establishing fitting coefficients as the discrepancies on the estimate of neutron absorbed doses were within 10%. The discrepancy can reach ∼25% for the bladder, the farthest organ from the target volume. Finally, the validation showed results in compliance with MC calculations since the discrepancies were also within 10% for head-and-neck and thoracic organs while they can reach ∼25%, again for pelvic organs. Conclusion: The parametric equation presents promising results and will be validated for other target sites as well as other facilities to go towards a universal method.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-664: Radiobiological Modeling of Prophylactic Cranial Irradiation in Mice

Purpose: Prophylactic cranial irradiation (PCI) is a clinical technique used to reduce the incidence of brain metastasis and improve overall survival in select patients with ALL and SCLC, and we have shown the potential of PCI in select breast cancer patients through a mouse model (manuscript in preparation). We developed a computational model using our experimental results to demonstrate the advantage of treating brain micro-metastases early. Methods: MATLAB was used to develop the computational model of brain metastasis and PCI in mice. The number of metastases per mouse and the volume of metastases from four- and eight-week endpoints were fit to normal and log-normal distributions, respectively. Model input parameters were optimized so that model output would match the experimental number of metastases per mouse. A limiting dilution assay was performed to validate the model. The effect of radiation at different time points was computationally evaluated through the endpoints of incidence, number of metastases, and tumor burden. Results: The correlation between experimental number of metastases per mouse and the Gaussian fit was 87% and 66% at the two endpoints. The experimental volumes and the log-normal fit had correlations of 99% and 97%. In the optimized model, the correlation between number of metastases per mouse and the Gaussian fit was 96% and 98%. The log-normal volume fit and the model agree 100%. The model was validated by a limiting dilution assay, where the correlation was 100%. The model demonstrates that cells are very sensitive to radiation at early time points, and delaying treatment introduces a threshold dose at which point the incidence and number of metastases decline. Conclusion: We have developed a computational model of brain metastasis and PCI in mice that is highly correlated to our experimental data. The model shows that early treatment of subclinical disease is highly advantageous.

62 RADIOLOGY AND NUCLEAR MEDICINE↗