Search NASA⌕ Search

SEARCH · Search NASA

Results for “flat geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,145 records · Page 64

TRUST Testing Procedure Documentation

The TRUST testbed was designed and fabricated to conduct vibration testing and validate the behavior of hyper-elastic foams in a pre-loaded condition. The main goals of this testbed design were to ensure symmetry, proper instrumentation alignment and mounting, simplified geometry to make the data analysis validation process more straightforward, and to apply and monitor the applied pre-load. Based off of the test parameters, a shaker system was purchased. The baseplate was designed to mount directly to the bolt holes provided on the top of the shaker table. It was determined that the specimens will be cylindrical and vary in thickness from 2-10mm. The baseplate riser, center-mass, and testbed cap were designed to be cylindrical to make alignment about the center axis more straightforward. It was determined to fabricate the parts previously mentioned using Aluminum 6061-T6 due to its stiffness in order to reduce the likelihood of the stiff material impacting the data being collected for the foam specimens. The design concept used to apply the pre-load to the testbed was a through bolt/nut configuration. A through hole was included in each piece of the testbed, specimens, and instrumentation large enough to allow for 1/8” clearance between the through bolt and each of these pieces. This was imperative to avoid causing friction and complicating the validation model. A load cell was then purchased and used to measure the pre-load being applied to the testbed. It was also required to collect data for 3 axes at 3 different locations 120° apart on the center-mass. This configuration was required to be placed on the cylindrical face and toward the top and bottom of the center-mass. Slots were milled out in the middle of each sensor block with tight tolerances for mounting each of the accelerometers at 120° apart. This same approach was taken to mount 2 accelerometers on the baseplate at 180° apart. Holes were milled out of the corners of each accelerometer mounting slot to relieve the corner and allow for a flat edge at the back of each slot. Sensor blocks were mounted into the center-mass using 6-32 bolts at the required locations. This initial testbed design was fabricated at the TA53 machine shop.

42 ENGINEERING↗

Cusps and cores in the presence of galactic bulges

In this paper, we study how the presence of bulge formation in galaxies influence their inner density profile, by means of an extended version of the Del Popolo (2009) semi-analytical model. As in Del Popolo (2009), the model takes into account the effect of baryons adiabatic contraction, ordered and random angular momentum, dynamical friction, and adds to the previous the effect of gas cooling, star formation, supernova feedback, and reionization. Our model shows that dwarf galaxies are bulgeless, in agreement with observations showing that the large majority of them has no stellar bulges, and are characterized by a flat profile well described by a Burkert profile. We then studied the effect of a bulge, added to the cored DM halo, on the density profile. In the case of a galaxy having a mass 10{sup 11}M{sub ⊙} the inner density profile has a slope α ≅ 0.65, for a bulge of 4.5 × 10{sup 9}M{sub ⊙} , while if bulge formation is not considered, the slope would be α ≅ 0.55. If the bulge is larger, 6.5 × 10{sup 9}M{sub ⊙} the slope is α ≅ 0.7. In the case of a larger galaxy with 10{sup 12}M{sub ⊙} the slope is α ≅ 0.85, while in absence of bulge it is α ≅ 0.75. We finally study how the inner slope α changes with the bulge mass, and we find a correlation among the two quantities. The result shows that bulge formation has an important role in shaping the inner DM density profile in agreement with Inoue and Saitoh (2011) result. The result implies that going from Sc to SO Hubble type the slope is slightly steepening due to the bulge formation, and due to the fact that early type galaxies have larger bulges.

79 ASTRONOMY AND ASTROPHYSICS↗

Iterative Atmospheric Correction Scheme and the Polarization Color of Alpine Snow

Characterization of the Earth's surface is crucial to remote sensing, both to map geomorphological features and because subtracting this signal is essential during retrievals of the atmospheric constituents located between the surface and the sensor. Current operational algorithms model the surface total reflectance through a weighted linear combination of a few geometry-dependent kernels, each devised to describe a particular scattering mechanism. The information content of these measurements is overwhelmed by that of instruments with polarization capabilities: proposed models in this case are based on the Fresnel reflectance of an isotropic distribution of facets. Because of its remarkable lack of spectral contrast, the polarized reflectance of land surfaces in the shortwave infrared spectral region, where atmospheric scattering is minimal, can be used to model the surface also at shorter wavelengths, where aerosol retrievals are attempted based on well-established scattering theories. In radiative transfer simulations, straightforward separation of the surface and atmospheric contributions is not possible without approximations because of the coupling introduced by multiple reflections. Within a general inversion framework, the problem can be eliminated by linearizing the radiative transfer calculation, and making the Jacobian (i.e., the derivative expressing the sensitivity of the reflectance with respect to model parameters) available at output. We present a general methodology based on a Gauss-Newton iterative search, which automates this procedure and eliminates de facto the need of an ad hoc atmospheric correction. In this case study we analyze the color variations in the polarized reflectance measured by the NASA Goddard Institute of Space Studies Research Scanning Polarimeter during a survey of late-season snowfields in the High Sierra. This insofar unique dataset presents challenges linked to the rugged topography associated with the alpine environment and a likely high water content due to melting. The analysis benefits from ancillary information provided by the NASA Langley High Spectral Resolution Lidar deployed on the same aircraft. The results obtained from the iterative scheme are contrasted against the surface polarized reflectance obtained ignoring multiple reflections, via the simplistic subtraction of the atmospheric scattering contribution. Finally, the retrieved reflectance is modeled after the scattering properties of a dense collection of ice crystals at the surface. Confirming that the polarized reflectance of snow is spectrally flat would allow to extend the techniques already in use for polarimetric retrievals of aerosol properties over land to the large portion of snow-covered pixels plaguing orbital and suborbital observations.

Polarized BRDF↗

A Fabrication Strategy for Reconfigurable Millimeter–Scale Metamaterials

Rather than depending on material composition to primarily dictate performance metrics, metamaterials can leverage geometry to achieve specific properties of interest. For example, reconfigurable metamaterials have enabled programmable shape transformations, tunable mechanical properties, and energy absorption. While several methods exist to fabricate such structures, they often place severe restrictions on manufacturing materials, or require significant manual assembly. Moreover, these arrays are typically composed of unit cells that are either macro–scale or micro–scale in dimension. Here, the fabrication gap is bridged, and laminate manufacturing is used to develop a method for designing reconfigurable metamaterials at the millimeter–scale, that is compatible with a wide range of materials, and that requires minimal manual assembly. In addition to showing the versatility of this fabrication method, how the use of laminate manufacturing affects the behavior of these multi–component arrays is also characterized. To this end, a numerical model that captures the deformations exhibited by the structures is developed, and an analytic model that predicts the strain of the structure under compressive stress is built. Overall, this approach can be leveraged to develop millimeter–scale metamaterials for applications that require reconfigurable materials, such as in the design of tunable acoustics, photonic waveguides, and electromagnetic devices.

36 MATERIALS SCIENCE↗

Integrating Sudo-Kaminaga Correlation to the Safety Analysis Code PARET-ANL

The accuracy and reliability of the reactor safety analysis code are critical because the specifications of the safety systems will depend on the analytical results for initiating events that could occur to the reactor. In safety analyses for power reactors, there exist many proficient and applicable computer codes such as RELAP5, CATHARE, RETRAN, or CATHENA. For non-power research reactors, an issue arises, however, due to lacking of such specialized codes. As a result, computer codes developed for the transient analysis of power reactors need to be applied carefully after proving their applicability to a specified research reactor. The safety analysis discussed in this paper concerns the prevention of fuel damage in hypothetical accidental scenarios for the new research reactor design at National Institute of Standards and Technology (NIST). One fuel integrity criterion is analyzed by investigating the Minimum Critical Heat Flux Ratio (MCHFR) in the core during the accidental transients. Some previous studies develop a relationship that correlates the nominal value of the minimum CHFR with the probability of CHF occurring and causing fuel damage. Using a statistical approach, the nominal value of the MCHFR for the low-enriched uranium (LEU) reactor needs to remain above the recommended limiting value to better ensure the safety of the research reactor. The probability of no fuel failure increases as the MCHFR increases. More importantly, as long as the MCHFR remains above the recommended limiting value of 1.301, the reactor will have a 90% probability that CHF is not reached. The safety analysis program PARET, developed by Argonne National Laboratory (ANL), is employed to obtain the CHFR information in this study. PARET/ANL is a digital computer programming code intended primarily for the analysis of test and research reactors that use plate-type (flat) fuel elements. This program has its own set of correlations that are used to calculate the CHFR. One of them is the Mirshak correlation, which was believed to provide the best estimation of the critical heat flux under the operating conditions of the new reactor at the time. Following the critical heat flux (CHF) experiments for vertical rectangular channels in the JRR-3 (Japan Research Reactor unit 3), the CHF calculations now use the Sudo- Kaminaga correlation. This correlation is of our interest because this method has an enhanced geometric similarity and an increased range of applicability that are more representative of the actual operating conditions of our current design, and has a more mechanistic approach [9]. Since the source code of PARET/ANL is inaccessible, a MATLAB-based utility has been written to integrate the Sudo-Kaminaga correlation as a substitute for the Mirshak correlation in the code. As a result, both the Mirshak and the Sudo-Kaminaga correlations are used to analyze the standard output from the PARET program to calculate the CHFR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Temperature Sapphire Pressure Sensors for Harsh Environments

The project aimed to develop and characterize an optical pressure sensor capable of withstanding high temperatures, up to 1000 °C. Survivability in harsh environments was enabled using sapphire for both the substrate and the optical fibers, therefore mitigating thermal expansion mismatch. Such material cannot be machined through conventional microfabrication techniques, and unique additive and subtractive methods had to be studied and implemented. Subtractive methods included laser-machining the sapphire substrate using a picosecond laser machining tool. At first, the parameters of importance were theoretically and experimentally evaluated such that the fluence, the pulse spacing, and the number of passes were found to strongly influence the laser ablation process. A simulation tool was designed to predict the final pattern when inputting a set of parameters and a profile. This model was complemented with laser ablation material physics models and Bayesian uncertainty analysis for one dimensional and three dimensional ablation processes. An additive process called thermocompression bonding was studied in order to seal the diaphragm substrate to the back cavity. At first, bonding strength using this technique was examined using the chevron-notch method that allow to determine the fracture toughness of this bond. This parameter is independent of the geometry used and therefore can be extended to other geometries used in actual sensor bonding. A theoretical and experimental study of internal damage caused by the laser micromachining of the sapphire material was carried out. The research identified enhanced strength and fracture toughness along laser ablated surfaces. This was determined using bend bar specimens and Vicker’s microindentations. Softening of the plasticity behavior (as indicated by nanoindentation experiments) was also investigated using finite deformation plasticity modeling via a contact mechanics finite element simulation. Good correlations between experiments and the model were achieved to determine material parameters that can be used in future MEMS based sensor design and modeling to minimize sensor failure loads. The enhanced strength and fracture toughness was determined to be due to compressive residual stress near laser ablated surfaces. This was confirmed through x-ray spectra taken along different crystal structure planes in combination and Bayesian uncertainty analysis. The Bayesian analysis inferred the entire residual strain tensor (six components) and the residual stress tensor. The results illustrated compressive in-plane stress was the most likely cause of enhanced strength and toughness after laser machining. Due to major equipment failures, a parallel route for fabricating the sensor was taken, using commercially available sapphire removal method (subtractive) and ceramic adhesive bonding (additive). The fully-packaged sensor utilized laser micromachining for the sapphire substrate fabrication and was comprised only of high-temperature-compatible materials. Calibration tests of the sensor in both room-temperature and high-temperature plane-wave tubes showed good linearity and consistent frequency response, in the tested frequency range. The sensor also showed good thermal stability in tests up to 300 °C, proving the fiber-optic lever and its packaging process to be a promising approach for high-temperature measurements. The calibration from 23 °C to 300 °C gave a raw sensitivity of 3.9 × 10 -7 V/Pa and a normalized sensitivity of 9.8 × 10 -8 Pa -1 which were consistent within the temperature range. The sensor had a resonance at 16.3 kHz and a flat band (±3 dB) up to 10.3 kHz. The noise floor of the sensor at 1 kHz was 316 nV/Hz 1/2 , resulting in a MDP of 0.8 Pa. Previously, diaphragm delamination due to CTE mismatch was found at 500 °C, causing packaging failure. Unfortunately high temperature validation in hot jet environment could not be made in time. In the future, it is suggested that the two sapphire substrates be bonded by thermal compression bonding with an intermediate platinum layer instead of using an alumina-based adhesive, and therefore achieve higher temperature capacity up to 1000 °C.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-F-T-481: Physics Evaluation of a Newly Released InCise™ Multileaf Collimator for CyberKnife M6™ System

Purpose: This work reports the results of the physics evaluation of a newly released InCise™2 Multileaf Collimator (MLC) installed in our institution. Methods: Beam property data was measured with unshielded diode and EBT2 films. The measurements included MLC leaf transmission, beam profiles, output factors and tissue-phantom ratios. MLC performance was evaluated for one month after commissioning. Weekly Garden Fence tests were performed for leaf / bank positioning in standard (A/P) and clinically relevant non-standard positions, before and after MLC driving exercises of 10+ minutes. Daily Picket Fence test and AQA test, End-to-End tests and dosimetric quality assurance were performed to evaluate the overall system performance. Results: All measurements including beam energy, flatness and symmetry, were within manufacture specifications. Leaf transmission was 0.4% <0.5% specification. The values of output factors ranged from 0.825 (7.6 mm × 7.5 mm) to 1.026 (115.0 mm × 100.1 mm). Average beam penumbra at 10 cm depth ranged from 2.7mm/2.7mm(7.6 mm × 7.5 mm) to 6.0 mm/6.2mm(84.6 mm × 84.7 mm). Slight penumbra difference (<10% from average penumbra for fields >20 mm) was observed in the direction perpendicular to leaf motion due to the tilting of the leaf housing. Mean leaf position offsets was −0.08±0.07mm and −0.13 ± 0.08 for X1 and X2 leaf banks in 13 Garden Fence tests. No significant difference on average leaf positioning offsets was observed between different leaf orientations and before/after MLC driving exercises. Six End-to-End tests showed 0.43±0.23mm overall targeting accuracy. Picket-Fence and AQA showed stable performance of MLC during the test period. Dosimetric point dose measurements for test cases agreed with calculation within 3%. All film measurements on relative dose had Gamma (2%, 2mm) passing rate of >95%. Conclusion: The Incise™2 MLC for CyberKnife M6™ was proven to be accurate and reliable, and it is currently in clinical use. Stanford was one of the physics evaluation sites for the newly released InCise 2 MLC for Accuray Inc.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-476: Performance of the AS1200 EPID for Periodic Photon Quality Assurance

Purpose: To assess the dosimetric performance of a new amorphous silicon flat-panel electronic portal imaging device (EPID) suitable for high-intensity, flattening-filter-free delivery mode. Methods: An EPID-based QA suite was created with automation to periodically monitor photon central-axis output and two-dimensional beam profile constancy as a function of gantry angle and dose-rate. A Varian TrueBeamTM linear accelerator installed with Developer Mode was used to customize and deliver XML script routines for the QA suite using the dosimetry mode image acquisition for an aS1200 EPID. Automatic post-processing software was developed to analyze the resulting DICOM images. Results: The EPID was used to monitor photon beam output constancy (central-axis), flatness, and symmetry over a period of 10 months for four photon beam energies (6x, 15x, 6xFFF, and 10xFFF). EPID results were consistent to those measured with a standard daily QA check device. At the four cardinal gantry angles, the standard deviation of the EPID central-axis output was <0.5%. Likewise, EPID measurements were independent for the wide range of dose rates (including up to 2400 mu/min for 10xFFF) studied with a standard deviation of <0.8% relative to the nominal dose rate for each energy. Also, profile constancy and field size measurements showed good agreement with the reference acquisition of 0° gantry angle and nominal dose rate. XML script files were also tested for MU linearity and picket-fence delivery. Using Developer Mode, the test suite was delivered in <60 minutes for all 4 photon energies with 4 dose rates per energy and 5 picket-fence acquisitions. Conclusion: Dosimetry image acquisition using a new EPID was found to be accurate for standard and high-intensity photon beams over a broad range of dose rates over 10 months. Developer Mode provided an efficient platform to customize the EPID acquisitions by using custom script files which significantly reduced the time. This work was funded in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-I-29: Generalized Relative Object Detectability (G-ROD): A Metric for Comparing X-Ray Imaging Detector Systems

Purpose: To determine the relative task-specific performance of two x-ray imaging detectors including the effect of other components of the imaging chain. Methods: The relative object detectability (ROD) was defined as the ratio of the integral of the detective-quantum efficiency (DQE) of a detector weighted by the square of the Fourier Transform (or frequency spectrum) of the object to the same integral for a second detector. The generalized ROD (G-ROD) is calculated by replacing DQE by the generalized DQE (GDQE) which includes geometric unsharpness and scatter to evaluate the total imaging chain. The G-ROD was calculated for the micro-angiographic fluoroscope (MAF) relative to a flat-panel detector (FPD) for low (1.05) and high (1.2) magnifications with two focal-spot sizes, small (0.3 mm) and medium (0.5 mm), and for the same value of scatter fraction. Solid spheres from 50 to 600 microns were simulated as the objects for this evaluation. The G-ROD results were compared with those of the ROD which considers the detectors alone. Results: For 50-micron spheres, the ROD is 7.93 and, for the small [medium] focus, the G-ROD is 6.74 [5.22] at low magnification and 3.03 [1.66] at high magnification, indicating superior performance of the MAF particularly at low magnification. Both ROD and G-ROD decrease monotonically with size and remain around one above 400-microns. The G-ROD decreases more dramatically with low compared to high magnification for both focal spots. Conclusion: In all cases, the MAF performs better than the FPD and the decreasing trend of the G-ROD indicates that the performance of both detectors becomes similar as the object size increases and becomes nearly equal above 400-micron diameter sphere size. Finally, increased magnification and focal-spot size decrease the G-ROD, indicting that they degrade the performance of the MAF more than that of the FPD for a small-object viewing task. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

60 APPLIED LIFE SCIENCES↗

Evaluating dosimetric accuracy of flattening filter free compensator-based IMRT: Measurements with diode arrays

Purpose: Compensator-based IMRT coupled with the high dose rate flattening filter free (FFF) beams offers an intriguing possibility of delivering an intensity modulated radiation field in just a few seconds. As a first step, the authors evaluate the dosimetric accuracy of the treatment planning system (TPS) FFF beam model with compensators. Methods: A 6 MV FFF beam from a TrueBeam accelerator (Varian Medical Systems, Palo Alto CA) was modeled in PINNACLE TPS (v. 9.0, Philips Radiation Oncology, Fitchburg WI). Flat brass slabs from 0.3 to 7 cm thick and an 18 deg. brass wedge were used to adjust the beam model. A 2D (MAPCHECK) and 3D (ARCCHECK) diode arrays (Sun Nuclear Corp, Melbourne FL), were investigated for use with the compensator FFF beams. Corrections for diode sensitivity caused by the spectral changes in the beam were introduced. Four compensator plans based on the AAPM TG-119 report were developed. A composite ion chamber measurement, beam by beam MAPCHECK measurements, and a composite ARCCHECK measurement were performed. The array results were analyzed with the same thresholds as in TG-119 report--3%/3 mm with global dose normalization--as well as with the more stringent combinations of the gamma analysis criteria. Results: The FFF beam shows a greater variation of the effective attenuation coefficient with brass thickness due to the prevalence of the low energy photons compared to the conventional 6X beam. As a result, a compromise had to be made while trying to achieve dose agreement for a combination of field sizes, brass thicknesses, and measurement depths ({>=}5 cm in water). An agreement of measured and calculated dose to within 1% was observed for brass thicknesses up to 2 cm. For the 3 cm slab, an error of up to 2.8% was noted for the field sizes above 10 x 10 cm{sup 2}, and up to 3.8% for the 5 x 5 cm{sup 2} field. Both diode arrays exhibit a substantial sensitivity drop as the compensator thickness increases, reaching 10% for a 7 cm brass slab. A simple correction based on the brass thickness along the ray was introduced to counteract this effect. Pooled for five profiles, the average ratio of uncorrected and corrected MAPCHECK to ion chamber readings are 0.966 and 1.008, respectively. With the proper correction, all MAPCHECK measurement to calculation comparisons exhibit 100%{gamma}(3%/3 mm) passing rates with global dose-error normalization. For the TG-119-type plans, the average {gamma}(2%/2 mm) passing rate with local normalization is 94% (range 87.8%-98.3%). The lower ARCCHECK{gamma}-analysis passing rates (corrected for diode sensitivity) are predictable based on the observed PDD discrepancies. However, with the 3%/3 mm thresholds and global normalization, the average {gamma}-analysis passing rate is 96.4% (range 89.9%-100%). Conclusions: MAPCHECK analysis demonstrates high passing rates with the stringent {gamma}(2%/2 mm) and local normalization criteria combination. The geometry of the ARCCHECK array creates a stress test for the FFF TPS model because of the shallow depth of the entrance diodes and large air cavity. Hence, the ARCCHECK{gamma}-analysis passing rates are lower than with the MAPCHECK, while still on par with TG-119.

61 RADIATION PROTECTION AND DOSIMETRY↗

Differential equations for cosmological correlators

Cosmological fluctuations retain a memory of the physics that generated them in their spatial correlations. The strength of correlations varies smoothly as a function of external kinematics, which is encoded in differential equations satisfied by cosmological correlation functions. In this work, we provide a broader perspective on the origin and structure of these differential equations. As a concrete example, we study conformally coupled scalar fields in a power-law cosmology. The wavefunction coefficients in this model have integral representations, with the integrands being the product of the corresponding flat-space results and “twist factors” that depend on the cosmological evolution. Similar twisted integrals arise for loop amplitudes in dimensional regularization, and their recent study has led to the discovery of rich mathematical structures and powerful new tools for computing multi-loop Feynman integrals in quantum field theory. The integrals of interest in cosmology are also part of a finite-dimensional basis of master integrals, which satisfy a system of first-order differential equations. We develop a formalism to derive these differential equations for arbitrary tree graphs. The results can be represented in graphical form by associating the singularities of the differential equations with a set of graph tubings. Upon differentiation, these tubings grow in a local and predictive fashion. In fact, a few remarkably simple rules allow us to predict — by hand — the equations for all tree graphs. While the rules of this “kinematic flow” are defined purely in terms of data on the boundary of the spacetime, they reflect the physics of bulk time evolution. We also study the analogous structures in tr ϕ 3 theory, and see some glimpses of hidden structure in the sum over planar graphs. This suggests that there is an autonomous combinatorial or geometric construction from which cosmological correlations, and the associated spacetime, emerge.

Cosmological models↗