Search NASA⌕ Search

SEARCH · Search NASA

Results for “mechanical loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Considerations for the Extension of Gas Path Analysis to Electrified Aircraft Propulsion Systems

Aircraft operators rely on gas path analysis techniques for monitoring the performance and health of their gas turbine engine assets. This is accomplished by analyzing discernable shifts in measurement parameters acquired from the engine. This paper reviews the founding mathematical principles of gas path analysis, including conventional approaches applied for estimating engine performance deterioration. Considerations for extending the application of gas path analysis techniques to Electrified Aircraft Propulsion (EAP) systems is also discussed, and simulated results from their application to an EAP concept comprised of turbomachinery and electrical system hardware is provided. Results are provided comparing the parameter estimation accuracy offered by taking a whole-system approach towards the problem setup versus that offered by analyzing each subsystem individually. For the latter, the importance of having accurate direct or inferred measurements of external mechanical torque loads placed upon turbomachinery shafts is emphasized.

Electrified Aircraft Propulsion↗

Considerations for the Extension of Gas Path Analysis to Electrified Aircraft Propulsion Systems

Aircraft operators rely on gas path analysis techniques for monitoring the performance and health of their gas turbine engine assets. This is accomplished by analyzing discernable shifts in measurement parameters acquired from the engine. This paper reviews the founding mathematical principles of gas path analysis, including conventional approaches applied for estimating engine performance deterioration. Considerations for extending the application of gas path analysis techniques to Electrified Aircraft Propulsion (EAP) systems is also discussed, and simulated results from their application to an EAP concept comprised of turbomachinery and electrical system hardware is provided. Results are provided comparing the parameter estimation accuracy offered by taking a whole-system approach towards the problem setup versus that offered by analyzing each subsystem individually. For the latter, the importance of having accurate direct or inferred measurements of external mechanical torque loads placed upon turbomachinery shafts is emphasized.

Electrified Aircraft Propulsion↗

Structural Analysis Findings of Open Spelter Socket Cable Terminations

A three-dimensional nonlinear finite element model of a representative open spelter socket termination was developed to examine the underlying mechanics of load transfer from a structural cable through the termination, the sensitivity of the joint design to wire brooming, zinc material nonlinearity, contact friction between the zinc and socket, voids within the zinc, and, finally, the effects of repeated loading on the joint. Primary factors affecting open spelter socket design are cast zinc plastic flow, depth of zinc slug seating, and quality of wire brooming. Zinc plasticity and proper brooming allows for efficient load transfer by developing confining pressure on the broomed wires in the narrow part of the socket, which keep the wires from pulling out of the zinc and shift failure to occur outside the socket. Highest wire stresses in the cable occur in the outer ring adjacent to the termination. While industry use of stay cables are typically designed to carry less than half the rated breaking force in aggregate, the constituent stresses within the zinc and the wires have the potential to exceed their respective allowable in operation and should be evaluated for fatigue- and creep-critical applications.

Pavel Babuska↗

Analytical Simulation of Effects of Local Mechanisms and Microstructure on Creep Response of Unidirectional Ceramic Matrix Composites

A micromechanics-based method has been developed to analyze the creep response of uncoated ceramic matrix minicomposites. Although the global stress level at which the creep response is analyzed is lower than the composite proportional limit, local stresses are assumed to be high enough that localized damage is present in the composite in the form of matrix microcracks. To model the composite creep response, including the effects of matrix cracking, a fiber shear lag-based methodology is employed. In this approach, stresses are assumed to vary in the fiber as a function of time and distance from the crack plane. The varying stresses are then used to compute the overall creep strain for the composite. Various assumptions regarding the level of matrix microcracking in the composite and the level of creep in the fiber and matrix in various portions of the composite unit cell are also examined. The creep response of the fiber is modeled using a linear Burgers model. The model is applied to a SiCf/SiC unidirectional minicomposite system. The computed creep results are compared to experimentally obtained values. The effects of the local fiber volume fraction on the overall creep response of the composite are also studied. This work will allow increased understanding of the key material damage mechanisms and load sharing that take place during creep conditions and can be expanded to provide improved analysis methods for full macrocomposites.

Micromechanics↗

Analytical Simulation of the Effects of Local Mechanisms and Microstructure on the Creep Response of Unidirectional Ceramic Matrix Composites

A micromechanics-based method has been developed to analyze the creep response of uncoated ceramic matrix minicomposites. Although the global stress level at which the creep response is analyzed is lower than the composite proportional limit, local stresses are assumed to be high enough that localized damage is present in the composite in the form of matrix microcracks. To model the composite creep response including the effects of matrix cracking, a fiber shear lag-based methodology is employed. In this approach, stresses are assumed to vary in the fiber as a function of time and distance from the crack plane. The varying stresses are then used to compute the overall creep strain for the composite. Various assumptions regarding the level of matrix microcracking in the composite, and the level of creep in the fiber and matrix in various portions of the composite unit cell, are also examined. The creep response of the fiber is modeled using a linear Burgers model. The model is applied to a SiC f /SiC unidirectional minicomposite system. The computed creep results are compared to experimentally obtained values. The effects of the local fiber volume fraction on the overall creep response of the composite are also studied. This work will allow increased understanding of the key material damage mechanisms and load sharing that take place during creep conditions and can be expanded to provide improved analysis methods for full macrocomposites.

Micromechanics↗

Analysis of NSTX Upgrade OH Magnet and Center Stack

The new ohmic heating (OH) coil and center stack for the National Spherical Torus Experiment (NSTX) upgrade are required to meet cooling and structural requirements for operation at the enhanced 1 Tesla toroidal field and 2 MA plasma current. The OH coil is designed to be cooled in the time between discharges by water flowing in the center of the coil conductor. We performed resistive heating and thermal hydraulic analyses to optimize coolant channel size to keep the coil temperature below 100 C and meet the required 20 minute cooling time. Coupled electromagnetic, thermal and structural FEA analyses were performed to determine if the OH coil meets the requirements of the structural design criteria. Structural response of the OH coil to its self-field and the field from other coils was analyzed. A model was developed to analyze the thermal and electromagnetic interaction of centerstack components such as the OH coil, TF inner legs and the Bellville washer preload mechanism. Torsional loads from the TF interaction with the OH and poloidal fields are transferred through the TF flag extensions via a torque transfer coupling to the rest of the tokamak structure. A 3D FEA analysis was performed to qualify this design. The results of these analyses, which will be presented in this paper, have led to the design of OH coil and centerstack components that meet the requirements of the NSTX-upgrade structural design criteria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Construction of an unyielding target for large horizontal impacts.

Sandia National Laboratories has constructed an unyielding target at the end of its 2000-foot rocket sled track. This target is made up of approximately 5 million pounds of concrete, an embedded steel load spreading structure, and a steel armor plate face that varies from 10 inches thick at the center to 4 inches thick at the left and right edges. The target/track combination will allow horizontal impacts at regulatory speeds of very large objects, such as a full-scale rail cask, or high-speed impacts of smaller packages. The load-spreading mechanism in the target is based upon the proven design that has been in use for over 20 years at Sandia's aerial cable facility. That target, with a weight of 2 million pounds, has successfully withstood impact forces of up to 25 million pounds. It is expected that the new target will be capable of withstanding impact forces of more than 70 million pounds. During construction various instrumentation was placed in the target so that the response of the target during severe impacts can be monitored. This paper will discuss the construction of the target and provide insights on the testing capabilities at the sled track with this new target.

33 ADVANCED PROPULSION SYSTEMS↗

Axisymmetric Simulations of the ITER Vertical Stability Coil

The ITER in-vessel coil system includes Vertical Stability (VS) coils and Edge Localized Mode (ELM) coils. There are two large VS ring coils, one upper and one lower. Each has four turns which are independently connected. The VS coils are needed for successful operation of ITER for most all of its operating modes. The VS coils must be highly reliable and fault tolerant. The operating environment includes normal and disruption Lorentz forces. To parametrically address all these design conditions in a tractable analysis requires a simplified model. The VS coils are predominately axisymmetric, and this suggests that an axisymmetric model can be meaningfully used to address the variations in mechanical design, loading, material properties, and time dependency. The axisymmetric finite element analysis described in this paper includes simulations of the bolted frictional connections used for the mounting details. Radiation and elastic-plastic response are modeled particularly for the extreme faulted conditions. Thermal connectivity is varied to study the effects of partial thermal connection of the actively cooled conductor to the remaining structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Refinement of Modeling Techniques for the Structural Evaluation of Hanford Single-Shell Nuclear Waste Storage Tanks

ABSTRACT Several tanks at the Hanford Site (in Washington State, USA) belong to the first generation of underground nuclear waste storage tanks known as single shell tanks (SSTs). These tanks were constructed between 1943 and 1964 and are well beyond their design life. This article discusses the structural analysis approach and modeling challenges encountered during the ongoing analysis of record (AOR) for evaluating the structural integrity of the SSTs. There are several geometrical and material nonlinearities and uncertainties to be dealt with while performing the modern finite element analysis of these tanks. The analysis takes into account the temperature history of the tanks and allowable mechanical operating loads of these tanks for proper estimation of creep strains and thermal degradation of material properties. The loads prescribed in the AOR models also include anticipated loads that these tanks may see during waste retrieval and closure. Due to uncertainty in a number of inputs to the models, sensitivity studies were conducted to address questions related to the boundary conditions to realistically or conservatively represent the influence of surrounding tanks in a tank farm, the influence of backfill excavation slope, the extent of backfill and the total extent of undisturbed soil surrounding the backfill. Because of the limited availability of data on the thermal and operating history for many of the individual tanks, some of the data was assumed or interpolated. However, the models developed for the analysis of record represent the bounding scenarios and include the loading conditions that the tanks were subjected to or anticipated. The modeling refinement techniques followed in the AOR resulted in conservative estimates for force and moment demands at various sections in the concrete tanks. This article discusses the modeling aspects related to Type-II and Type-III SSTs. The modeling techniques, methodology and evaluation criteria developed for evaluating the structural integrity of SSTs at Hanford are in general applicable to any similar tanks or underground concrete storage structures.

Waste Managament, Single Shell Tanks, Structural E↗

Multi-functional composite structures

Fibrous monolith processing techniques to fabricate multifunctional structures capable of performing more than one discrete function such as structures capable of bearing structural loads and mechanical stresses in service and also capable of performing at least one additional non-structural function.

36 MATERIALS SCIENCE↗

Refinement of Modeling Techniques for the Structural Evaluation of Hanford Single-Shell Nuclear Waste Storage Tanks

Abstract: A total of 149 tanks out of 177 at the Hanford Site (in Washington State, USA) belong to the first generation of underground nuclear waste storage tanks known as single shell tanks (SSTs). These tanks were constructed between 1943 and 1964 and are well beyond their design life. All the SSTs had been removed from active service by November 1980 and have been later interim stabilized by removing the pumpable liquids. The remaining waste in the tanks is in the form of salt cake and sludge awaiting r permanent disposal.. The evaluation of the structural integrity of these tanks is of utmost importance not only for the continued safe storage of the waste until waste retrieval and closure, but also to assure safe retrieval and closure operations. This article discusses the structural analysis approach, modeling challenges and issues encountered during the ongoing analysis of record (AOR) for evaluating the structural integrity of the SSTs. There are several geometrical and material nonlinearities and uncertainties to be dealt with while performing the modern finite element analysis of these tanks. Several studies were conducted to refine the models in order to minimize modeling artifacts introduced by soil arching, boundary effects, concrete cracking, and concrete-soil interface behavior. The analysis takes into account the temperature history of the tanks and allowable mechanical operating loads of these tanks for proper estimation of creep strains and thermal degradation of material properties. The loads imposed in the AOR models also include anticipated loads that these tanks may see during waste retrieval and closure. Due to uncertainty in a number of inputs to the models, sensitivity studies were conducted to address questions related to the boundary conditions to realistically or conservatively represent the influence of surrounding tanks in a tank farm, the influence of backfill excavation slope, the extent of backfill and the total extent of undisturbed soil surrounding the backfill. The article also discusses the criteria and design standards used for evaluating the structural integrity of these underground concrete tanks. Because of the non-availability of complete data on the thermal and operating history for many of the individual tanks, some of the data was assumed or interpolated. However, the models developed for the analysis of record represent the bounding scenarios and include the worst and extreme loading cases that the tanks were subjected to or anticipated. The modeling refinement techniques followed in the AOR resulted in conservative estimates for force and moment demands at various sections in the concrete tanks. The SSTs are classified into 4 types as per their configuration and capacity. This article discusses the modeling aspects related to two types of SSTs that have been analyzed until now. The TOLA results combined with seismic demands from seismic analysis for the analysis of record indicate that the tanks analyzed are structurally stable as per the evaluation criteria established. These results are presented in a separate article. The modeling techniques, methodology and evaluation criteria developed for evaluating the structural integrity of SSTs at Hanford are in general applicable to any similar tanks or underground concrete storage structures.

Single Shell Tank, Structural analysis, Structural↗

Degradation in PV Encapsulation Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.

14 SOLAR ENERGY↗

Refinement of Modeling Techniques for the Structural Evaluation of Hanford Single-Shell Nuclear Waste Storage Tanks - 12288

The single-shell tanks at the Hanford Site (in Washington State, USA) were constructed between 1943 and 1964 and are well beyond their estimated 25 year design life. This article discusses the structural analysis approach and modeling challenges encountered during the ongoing analysis of record for evaluating the structural integrity of the single-shell tanks. There are several geometrical and material nonlinearities and uncertainties to be dealt with while performing the modern finite element analysis of these tanks. The analysis takes into account the temperature history of the tanks and allowable mechanical operating loads for proper estimation of creep strains and thermal degradation of material properties. The loads prescribed in the analysis of record models also include anticipated loads that may occur during waste retrieval and closure. Due to uncertainty in a number of modeling details, sensitivity studies were conducted to address questions related to boundary conditions that realistically or conservatively represent the influence of surrounding tanks in a tank farm, the influence of backfill excavation slope, the extent of backfill and the total extent of undisturbed soil surrounding the backfill. Because of the limited availability of data on the thermal and operating history for many of the individual tanks, some of the data was assumed or interpolated. However, the models developed for the analysis of record represent the bounding scenarios and include the loading conditions that the tanks were subjected to or anticipated. The modeling refinement techniques followed in the analysis of record resulted in conservative estimates for force and moment demands at various sections in the concrete tanks. This article discusses the modeling aspects related to Type-II and Type-III single-shell tanks. The modeling techniques, methodology and evaluation criteria developed for evaluating the structural integrity of single-shell tanks at Hanford are in general applicable to other similar tanks or underground concrete storage structures. This article presented the details of the finite element models and analysis approach followed during the ongoing effort to establish structural integrity of single shell tanks at the Hanford site. The details of the material constitutive models applicable to the underground Hanford concrete tanks that capture the thermal and creep induce degradation are also presented. The thermal profiles were developed based on the available tank temperature data for the Type II and Type III single-shell tanks, and they were chosen to yield conservative demands under the thermal and operating loads analysis of these tanks. Sensitivity studies were conducted to address two issues regarding the soils modeled around the single-shell tanks. The results indicate that excluding the boundary separating the backfill soil from the undisturbed soil will result in conservative demands (plots 14b and 14c green lines for circumferential Demand/Capacity ratios). The radial extent study indicated that the soil model extending to 240 ft gave more conservative results than the model with 62 ft of soil (plots 17a and 17c magenta lines for hoop Demand/Capacity ratios). Based on these results, a 240 ft far-field soil boundary with backfill throughout the lateral extent was recommended and used for the finite element models used in the Type-II and Type-III analyses of record. The modeling effort and sensitivity studies discussed in this article helped in developing bounding models for the structural integrity evaluation of single shell tanks at the Hanford site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Open-air Demolition: Validation of EPA Approved Alternative Method for Emission Estimation - 19397

Emissions from open-air demolition of US Department of Energy (DOE) facilities are regulated by the US Environmental Protection Agency (EPA) under 40 CFR 61 subpart H. This regulation requires that facilities estimate emissions using an EPA approved method from activities such as open-air demolition prior to commencing the activity. Should those emissions exceed certain thresholds, the facility may be required to obtain an Approval to Construct or Modify the facility and/or installed monitoring methods meeting methods acceptable to EPA. There are no EPA approved methods that are specific to open-air demolition methods. For this project the DOE and CH2M Hill BWXT elected to prepare an alternative method specific to open-air demolition. EPA conditionally approved the method but required validation of the method during the demolition of the Vitrification Facility at the West Valley Demonstration Project (WVDP) before use for open-air demolition at other WVDP structures. The validation method included detailed source characterization, close-in ambient samplers, and a comparison of measured results to predicted emissions using AERMOD (American Meteorological Society (AMS) and U.S. Environmental Protection Agency (EPA) Regulatory Model). The methods evaluated include hydraulic hammers, mechanical shears, load out of waste and handling of the debris piles. The validation method involved the collection and analysis of ambient air samples from air samplers located at strategic locations within the projected plume path of the demolition activities. The analytical results from the air samplers were then compared to ambient air concentrations predicted at the sampler locations with the EPA model AERMOD. The input to the AERMOD software is a source term developed weekly using the alternative method and material at risk disturbed during each week. To account for the building wake effects of the surrounding structures, virtual point sources were developed in the AERMOD model and placed at the locations of the demolition, debris piles, debris handling and load out areas. It was found that the factors used for hydraulic hammering were extremely conservative and that emissions from the debris pile were not only the primary emission source, but that the moisture content of the debris pile and the wind speed were critical factors that must be considered in future open-air demolition projects. Based on the results of the validation process, adjustments were made to the alternative method. The final validated alternative method provides an approach for estimating airborne emissions from open-air demolition methods and techniques. The method will be used in lieu of 40 CFR 61 Appendix D to estimate emissions from future open-air demolition projects at the WVDP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗