Search NASA⌕ Search

SEARCH · Search NASA

Results for “probability and statistical methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Mammographic quantitative image analysis and biologic image composition for breast lesion characterization and classification

Purpose: To investigate whether biologic image composition of mammographic lesions can improve upon existing mammographic quantitative image analysis (QIA) in estimating the probability of malignancy. Methods: The study population consisted of 45 breast lesions imaged with dual-energy mammography prior to breast biopsy with final diagnosis resulting in 10 invasive ductal carcinomas, 5 ductal carcinomain situ, 11 fibroadenomas, and 19 other benign diagnoses. Analysis was threefold: (1) The raw low-energy mammographic images were analyzed with an established in-house QIA method, “QIA alone,” (2) the three-compartment breast (3CB) composition measure—derived from the dual-energy mammography—of water, lipid, and protein thickness were assessed, “3CB alone”, and (3) information from QIA and 3CB was combined, “QIA + 3CB.” Analysis was initiated from radiologist-indicated lesion centers and was otherwise fully automated. Steps of the QIA and 3CB methods were lesion segmentation, characterization, and subsequent classification for malignancy in leave-one-case-out cross-validation. Performance assessment included box plots, Bland–Altman plots, and Receiver Operating Characteristic (ROC) analysis. Results: The area under the ROC curve (AUC) for distinguishing between benign and malignant lesions (invasive and DCIS) was 0.81 (standard error 0.07) for the “QIA alone” method, 0.72 (0.07) for “3CB alone” method, and 0.86 (0.04) for “QIA+3CB” combined. The difference in AUC was 0.043 between “QIA + 3CB” and “QIA alone” but failed to reach statistical significance (95% confidence interval [–0.17 to + 0.26]). Conclusions: In this pilot study analyzing the new 3CB imaging modality, knowledge of the composition of breast lesions and their periphery appeared additive in combination with existing mammographic QIA methods for the distinction between different benign and malignant lesion types.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-CD-207B-07: Noise Modeling of Single Photon Avalanche Diode (SPAD) for Photon Counting CT Applications

Purpose: Silicon photomultiplier (SiPM) has recently emerged as a promising photodetector for biomedical imaging applications. Due to its high multiplication gain (comparable to PMT), fast timing, low cost and compactness, it is considered a good candidate for photon counting CT. Dark noise is a limiting factor which impacts both energy resolution and detection dynamic range. Our goal is to develop a comprehensive model for noise sources for SiPM sensors. Methods: The physical parameters used in this work were based upon a test SPAD fabricated in 130nm CMOS process. The SPAD uses an n+/p-well junction, which is isolated from the p-substrate by a deep n-well junction. Inter-avalanche time measurement was used to record the time interval between two adjacent avalanche pulses. After collecting 1×106 counts, the histogram was obtained and multiple exponential fitting process was used to extract the lifetime associated with the traps within the bandgap. Results: At room temperature, the breakdown voltage of the SPAD is ∼11.4V and shows a temperature coefficient of 7.7mV/°C. The dark noise of SPAD increases with both the excess biasing voltage and temperature. The primary dark counts from the model were validated against the measurement results. A maximum relative error of 8.7% is observed at 20 °C with an excess voltage of 0.5V. The probabilities of after-pulsing are found to be dependent of both temperature and excess voltage. With 0.5V excess voltage, the after-pulsing probability is 63.5% at - 30 °C and drops to ∼6.6% at 40 °C. Conclusion: A comprehensive noise model for SPAD sensor was proposed. The model takes into account of static, dynamic and statistical behavior of SPADs. We believe that this is the first SPAD circuit simulation model that includes the band-to-band tunneling dark noise contribution and temporal dependence of the after-pulsing probability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Random Forests to Predict Rectal Toxicity Following Prostate Cancer Radiation Therapy

Purpose: To propose a random forest normal tissue complication probability (RF-NTCP) model to predict late rectal toxicity following prostate cancer radiation therapy, and to compare its performance to that of classic NTCP models. Methods and Materials: Clinical data and dose-volume histograms (DVH) were collected from 261 patients who received 3-dimensional conformal radiation therapy for prostate cancer with at least 5 years of follow-up. The series was split 1000 times into training and validation cohorts. A RF was trained to predict the risk of 5-year overall rectal toxicity and bleeding. Parameters of the Lyman-Kutcher-Burman (LKB) model were identified and a logistic regression model was fit. The performance of all the models was assessed by computing the area under the receiving operating characteristic curve (AUC). Results: The 5-year grade ≥2 overall rectal toxicity and grade ≥1 and grade ≥2 rectal bleeding rates were 16%, 25%, and 10%, respectively. Predictive capabilities were obtained using the RF-NTCP model for all 3 toxicity endpoints, including both the training and validation cohorts. The age and use of anticoagulants were found to be predictors of rectal bleeding. The AUC for RF-NTCP ranged from 0.66 to 0.76, depending on the toxicity endpoint. The AUC values for the LKB-NTCP were statistically significantly inferior, ranging from 0.62 to 0.69. Conclusions: The RF-NTCP model may be a useful new tool in predicting late rectal toxicity, including variables other than DVH, and thus appears as a strong competitor to classic NTCP models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the Contribution of Turbulent Boundary Layers to the Noise Inside a Fuselage

The following report deals in preliminary fashion with the transmission through a fuselage of random noise generated on the fuselage skin by a turbulent boundary layer. The concept of attenuation is abandoned and instead the problem is formulated as a sequence of two linear couplings: the turbulent boundary layer fluctuations excite the fuselage skin in lateral vibrations and the skin vibrations induce sound inside the fuselage. The techniques used are those required to determine the response of linear systems to random forcing functions of several variables. A certain degree of idealization has been resorted to. Thus the boundary layer is assumed locally homogeneous, the fuselage skin is assumed flat, unlined and free from axial loads and the 'cabin' air is bounded only by the vibrating plate so that only outgoing waves are considered. Some of the details of the statistical description have been simplified in order to reveal the basic features of the problem. The results, strictly applicable only to the limiting case of thin boundary layers, show that the sound pressure intensity is proportional to the square of the free stream density, the square of cabin air density and inversely proportional to the first power of the damping constant and to the second power of the plate density. The dependence on free stream velocity and boundary layer thickness cannot be given in general without a detailed knowledge of the characteristics of the pressure fluctuations in the boundary layer (in particular the frequency spectrum). For a flat spectrum the noise intensity depends on the fifth power of the velocity and the first power of the boundary layer thickness. This suggests that boundary layer removal is probably not an economical means for decreasing cabin noise. In general, the analysis presented here only reduces the determination of cabin noise intensity to the measurement of the effect of any one of our variables (free stream velocity, boundary layer thickness, plate thickness or the characteristic velocity of propagation in the plate). The plate generates noise by vibrating in resonance over a wide range of frequencies and increasing the damping constant is consequently an effective method of decreasing noise generation. One of the main features of the results is that the relevant quantities upon which noise intensity depends are non-dimensional numbers in which boundary layer and plate properties enter as ratios. This is taken as an indication that in testing models of structures for boundary layer noise it is not sufficient to duplicate in the model the structural characteristics of the fuselage. One must match properly the characteristics of the exicitng pressure fluctuations to that of the structure.

Corcos, G. M.↗

Potential Multi-Component Structure of the Debris Disk Around HIP 17439 Revealed by Herschel DUNES

Context. The dust observed in debris disks is produced through collisions of larger bodies left over from the planet/planetesimal formation process. Spatially resolving these disks permits to constrain their architecture and thus that of the underlying planetary/planetesimal system. Aims. Our Herschel open time key program DUNES aims at detecting and characterizing debris disks around nearby, sun-like stars. In addition to the statistical analysis of the data, the detailed study of single objects through spatially resolving the disk and detailed modeling of the data is a main goal of the project. Methods. We obtained the first observations spatially resolving the debris disk around the sun-like star HIP 17439 (HD 23484) using the instruments PACS and SPIRE on board the Herschel Space Observatory. Simultaneous multi-wavelength modeling of these data together with ancillary data from the literature is presented. Results. A standard single component disk model fails to reproduce the major axis radial profiles at 70 μm, 100 μm, and 160 μm simultaneously. Moreover, the best-fit parameters derived from such a model suggest a very broad disk extending from few au up to few hundreds of au from the star with a nearly constant surface density which seems physically unlikely. However, the constraints from both the data and our limited theoretical investigation are not strong enough to completely rule out this model. An alternative, more plausible, and better fitting model of the system consists of two rings of dust at approx. 30 au and 90 au, respectively, while the constraints on the parameters of this model are weak due to its complexity and intrinsic degeneracies. Conclusions. The disk is probably composed of at least two components with different spatial locations (but not necessarily detached), while a single, broad disk is possible, but less likely. The two spatially well-separated rings of dust in our best-fit model suggest the presence of at least one high mass planet or several low-mass planets clearing the region between the two rings from planetesimals and dust.

sun-like stars↗

Temporal Lobe Reactions After Radiotherapy With Carbon Ions: Incidence and Estimation of the Relative Biological Effectiveness by the Local Effect Model

Purpose: To identify predictors for the development of temporal lobe reactions (TLR) after carbon ion radiation therapy (RT) for radiation-resistant tumors in the central nervous system and to evaluate the predictions of the local effect model (LEM) used for calculation of the biologically effective dose. Methods and Materials: This retrospective study reports the TLR rates in patients with skull base chordomas and chondrosarcomas irradiated with carbon ions at GSI, Darmstadt, Germany, in the years 2002 and 2003. Calculation of the relative biological effectiveness and dose optimization of treatment plans were performed on the basis of the LEM. Clinical examinations and magnetic resonance imaging (MRI) were performed at 3, 6, and 12 months after RT and annually thereafter. Local contrast medium enhancement in temporal lobes, as detected on MRI, was regarded as radiation-induced TLR. Dose-volume histograms of 118 temporal lobes in 59 patients were analyzed, and 16 therapy-associated and 2 patient-associated factors were statistically evaluated for their predictive value for the occurrence of TLR. Results: Median follow-up was 2.5 years (range, 0.3--6.6 years). Age and maximum dose applied to at least 1 cm{sup 3} of the temporal lobe (D{sub max,V-1cm}3, maximum dose in the remaining temporal lobe volume, excluding the volume 1 cm{sup 3} with the highest dose) were found to be the most important predictors for TLR. Dose response curves of D{sub max,V-1cm}3 were calculated. The biologically equivalent tolerance doses for the 5% and 50% probabilities to develop TLR were 68.8 {+-} 3.3 Gy equivalents (GyE) and 87.3 {+-} 2.8 GyE, respectively. Conclusions: D{sub max,V-1cm}3 is predictive for radiation-induced TLR. The tolerance doses obtained seem to be consistent with published data for highly conformal photon and proton irradiations. We could not detect any clinically relevant deviations between clinical findings and expectations based on predictions of the LEM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-51: Bayesian Network Models for Radiotherapy Error Detection

Purpose: To develop a probabilistic model of radiotherapy plans using Bayesian networks that will detect potential errors in radiation delivery. Methods: Semi-structured interviews with medical physicists and other domain experts were employed to generate a set of layered nodes and arcs forming a Bayesian Network (BN) which encapsulates relevant radiotherapy concepts and their associated interdependencies. Concepts in the final network were limited to those whose parameters are represented in the institutional database at a level significant enough to develop mathematical distributions. The concept-relation knowledge base was constructed using the Web Ontology Language (OWL) and translated into Hugin Expert Bayes Network files via the the RHugin package in the R statistical programming language. A subset of de-identified data derived from a Mosaiq relational database representing 1937 unique prescription cases was processed and pre-screened for errors and then used by the Hugin implementation of the Estimation-Maximization (EM) algorithm for machine learning all parameter distributions. Individual networks were generated for each of several commonly treated anatomic regions identified by ICD-9 neoplasm categories including lung, brain, lymphoma, and female breast. Results: The resulting Bayesian networks represent a large part of the probabilistic knowledge inherent in treatment planning. By populating the networks entirely with data captured from a clinical oncology information management system over the course of several years of normal practice, we were able to create accurate probability tables with no additional time spent by experts or clinicians. These probabilistic descriptions of the treatment planning allow one to check if a treatment plan is within the normal scope of practice, given some initial set of clinical evidence and thereby detect for potential outliers to be flagged for further investigation. Conclusion: The networks developed here support the use of probabilistic models into clinical chart checking for improved detection of potential errors in RT plans.

60 APPLIED LIFE SCIENCES↗

Bayesian uncertainty quantification for nuclear matter incompressibility

Within a Bayesian statistical framework using the standard Skyrme-Hartree-Fock model, the maximum a posteriori (MAP) values and uncertainties of nuclear matter incompressibility and isovector interaction parameters are inferred from the experimental data of giant resonances and neutron-skin thicknesses of typical heavy nuclei. Furthermore, with the uncertainties of the isovector interaction parameters constrained by the data of the isovector giant dipole resonance and the neutron-skin thickness, we have obtained K 0 = 223$^{+7}_{–8}$ MeV at 68% confidence level using the data of the isoscalar giant monopole resonance in 208 Pb measured at the Research Center for Nuclear Physics (RCNP), Japan, and at the Texas A&M University, USA. Although the corresponding 120 Sn data gives a MAP value for K 0 about 5 MeV smaller than the 208 Pb data, there are significant overlaps in their posterior probability distribution functions.

190 ≤ A ≤ 219↗

The Turbulent/Non-Turbulent Interface Bounding a Far-Wake

The velocity fields of a turbulent wake behind a flat plate obtained from the direct numerical simulations of Moser et al. are used to study the structure of the flow in the intermittent zone where there are, alternately, regions of fully turbulent flow and non-turbulent velocity fluctuations either side of a thin randomly moving interface. Comparisons are made with a wake that is 'forced' by amplifying initial velocity fluctuations. There is also a random temperature field T in the flow; T varies between constant values of 0.0 and 1.0 on the sides of the wake. The value of the Reynolds number based on the centreplane mean velocity defect and halfwidth b of the wake is Re approx. = 2000. It is found that the thickness of the continuous interface is about equal to 0.07b, whereas the amplitude of fluctuations of the instantaneous interface displacement y(sub I)(t) is an order of magnitude larger, being about 0.5b. This explains why the mean statistics of vorticity in the intermittent zone can be calculated in terms of the probability distribution of y(sub I) and the instantaneous discontinuity in vorticity across the interface. When plotted as functions of y - y(sub I), the conditional mean velocity (U) and temperature (T) profiles show sharp jumps Delta(U) and Delta(T) at the interface adjacent to a thick zone where (U) and (T) vary much more slowly. Statistics for the vorticity and velocity variances, available in such detail only from DNS data, show how streamwise and spanwise components of vorticity are generated by vortex stretching in the bulges of the interface. Flow fields around the interface, analyzed in terms of the local streamline pattern, confirm previous results that the advancement of the vortical interface into the irrotational flow is driven by large-scale eddy motion. It is argued that because this is an inviscid mechanism the entrainment process is not sensitive to the value of Re, and that small-scale nibbling only plays a subsidiary role. While mean Reynolds stresses decrease gradually in the intermittent zone, conditional stresses are found to decrease sharply towards zero at the interface. Using one-point turbulence models applied to either unconditional or conditional statistics for the turbulent region and then averaged, the entrainment rate E(sub b) would, if calculated exactly, be zero. But if computed with standard computational methods, E(sub b) would be non-zero because of numerical diffusion. It is concluded that the current practice in statistical models of approximating entrainment by a diffusion process is computationally arbitrary and physically incorrect. An analysis shows how E(sub b) is related to Delta(U) and the jump in shear stress at the interface, and correspondingly to Delta(T) and the heat flux.

Bisset, David K.↗

The IPAC Image Subtraction and Discovery Pipeline for the Intermediate Palomar Transient Factory

We describe the near real-time transient-source discovery engine for the intermediate Palomar Transient Factory (iPTF), currently in operations at the Infrared Processing and Analysis Center (IPAC), Caltech. We coin this system the IPAC/iPTF Discovery Engine (or IDE). We review the algorithms used for PSF-matching, image subtraction, detection, photometry, and machine-learned (ML) vetting of extracted transient candidates. We also review the performance of our ML classifier. For a limiting signal-to-noise ratio of 4 in relatively unconfused regions, bogus candidates from processing artifacts and imperfect image subtractions outnumber real transients by approximately equal to 10:1. This can be considerably higher for image data with inaccurate astrometric and/or PSF-matching solutions. Despite this occasionally high contamination rate, the ML classifier is able to identify real transients with an efficiency (or completeness) of approximately equal to 97% for a maximum tolerable false-positive rate of 1% when classifying raw candidates. All subtraction-image metrics, source features, ML probability-based real-bogus scores, contextual metadata from other surveys, and possible associations with known Solar System objects are stored in a relational database for retrieval by the various science working groups. We review our efforts in mitigating false-positives and our experience in optimizing the overall system in response to the multitude of science projects underway with iPTF.

methods: analytical – methods: data analysis –↗

A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT

Purpose: Energy discriminating, photon-counting detectors (PCDs) are an emerging technology for computed tomography (CT) with various potential benefits for clinical CT. The photon energies measured by PCDs can be distorted due to the interactions of a photon with the detector and the interaction of multiple coincident photons. These effects result in distorted recorded x-ray spectra which may lead to artifacts in reconstructed CT images and inaccuracies in tissue identification. Model-based compensation techniques have the potential to account for the distortion effects. This approach requires only a small number of parameters and is applicable to a wide range of spectra and count rates, but it needs an accurate model of the spectral distortions occurring in PCDs. The purpose of this study was to develop a model of those spectral distortions and to evaluate the model using a PCD (model DXMCT-1; DxRay, Inc., Northridge, CA) and various x-ray spectra in a wide range of count rates. Methods: The authors hypothesize that the complex phenomena of spectral distortions can be modeled by: (1) separating them into count-rate independent factors that we call the spectral response effects (SRE), and count-rate dependent factors that we call the pulse pileup effects (PPE), (2) developing separate models for SRE and PPE, and (3) cascading the SRE and PPE models into a combined SRE+PPE model that describes PCD distortions at both low and high count rates. The SRE model describes the probability distribution of the recorded spectrum, with a photo peak and a continuum tail, given the incident photon energy. Model parameters were obtained from calibration measurements with three radioisotopes and then interpolated linearly for other energies. The PPE model used was developed in the authors’ previous work [K. Taguchi et al., “Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects,” Med. Phys. 38(2), 1089–1102 (2011)]. The agreement between the x-ray spectra calculated by the cascaded SRE+PPE model and the measured spectra was evaluated for various levels of deadtime loss ratios (DLR) and incident spectral shapes, realized using different attenuators, in terms of the weighted coefficient of variation (COV{sub W}), i.e., the root mean square difference weighted by the statistical errors of the data and divided by the mean. Results: At low count rates, when DLR < 10%, the distorted spectra measured by the DXMCT-1 were in agreement with those calculated by SRE only, with COV{sub W}'s less than 4%. At higher count rates, the measured spectra were also in agreement with the ones calculated by the cascaded SRE+PPE model; with PMMA as attenuator, COV{sub W} was 5.6% at a DLR of 22% and as small as 6.7% for a DLR as high as 55%. Conclusions: The x-ray spectra calculated by the proposed model agreed with the measured spectra over a wide range of count rates and spectral shapes. The SRE model predicted the distorted, recorded spectra with low count rates over various types and thicknesses of attenuators. The study also validated the hypothesis that the complex spectral distortions in a PCD can be adequately modeled by cascading the count-rate independent SRE and the count-rate dependent PPE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Environmental Characterization Scans Using Sodium-Iodide Gamma Spectroscopy to Determine Ra-226 Concentration in Surface Soil - 16326

The recent natural gas drilling boom has brought heightened attention to the issue of TENORM waste management. Radioactive residues from the extraction, treatment, and purification of materials containing uranium and thorium, or their progeny, pose a public health hazard primarily in the form of ground water contamination. Hydraulic fracturing can liberate formation waters from shale; the high salinity of which can cause radium to move with the water to the surface. The disposal and handling of this water has been a subject of public controversy. For soil remediation projects, radium-226 is generally one of the radionuclides of concern due to its alpha emissions. However performing a survey scan for Ra-226 is difficult because its photon emissions are low energy and have minimal probability of emission per decay (186.2 keV, 3.3% abundance). Additionally resolving its emission from U-235 (185.7 keV, 57% abundance) with field instrumentation is not feasible. Therefore detection of Ra-226 relies on the presence and photon emissions of its progeny. This paper outlines methodology for calculating the minimum detectable concentration of Ra-226 in characterization scans using a sodium-iodide detector array coupled with a multi-channel analyzer. Using progeny ingrowth as a detection proxy requires knowing decay time in order to determine progeny emission rates. Knowledge of site history, process, and prior survey results can be key in determining an accurate decay time. However in the absence of such information in-situ measurements can be used to estimate decay time by comparing observed progeny emission ratios against established values. These values are determined using Oak Ridge National Laboratory's ORIGEN-ARP program to generate photon energy spectra for Ra-226 and its progeny at specified time intervals. Once decay time is established, the detector's minimum detectable concentration can be calculated by synthesizing the expected emission spectra and Los Alamos National Laboratory's Monte Carlo N-Particle transport code to simulate detector response. Traditionally, one of the steps in calculating a system's minimum detectable concentration is to place an appropriate button source under the detector, record the response, and then move the source by a specified increment. This process is repeated until the detector's spatial efficiency has been mapped. Due to the impracticality of performing this with Ra-226 button sources of varying decay times, Monte Carlo N-Particle transport code was utilized to determine the detector's spatial efficiency. A dime sized source with the established emission spectra was placed into the center of a rectangle of soil. This rectangle, including the source, was used as a lattice element to fill the region of space below the detector. The simulation was designed to track the energy distribution of pulses created in the sodium iodide crystal using the F8 tally, and was setup to isolate each source; thereby correlating detector response to source position. The simulation output required post-processing to determine conversion factors from counts per second to disintegrations per second. Post-processing accounted for subtraction of the Compton continuum, and average the data over the scanning pattern to obtain the expected spatial sensitivity during a characterization study. This was performed for the following photo-peaks: 609 keV (Bi-214), and 1764 keV (Bi-214). For calculation of the scan minimum detectable concentration, the surveyor efficiency coefficient from NUREG 1507 was supplanted in favor of a scan speed deviation factor. This was used because the detector utilizes computerized data collection (spatial and spectral). This report finds that, for two shielded 10.16 cm x 10.16 cm x 40.64 cm sodium-iodide crystals with integrated multi-channel analyzers, the minimum detectable concentration in surface soils is less than 1 pCi per gram Ra-226 for a 1 second survey measurement. These results assume a volumetric source with a maximum depth of 15.24 cm and a minimum decay time of 21 days. Verification of the system's capabilities was performed by sending soil samples from scanned areas, and locations where in-situ measurements were performed, to an independent laboratory for analysis. The laboratory results demonstrated that scanned area was principally comprised of soil containing less than 1 pCi per gram Ra-226. This borders the system MDC and it underestimated the concentration of radium in the soil. The probable causes of this is escape of radon gas from the surface soil. Radon is the daughter of radium, and has a high mobility in soil. If the gas escapes, then the progeny used as the detection proxy will be present in lower than expected concentrations. Radionuclide identification using high volume sodium-iodide crystals in low level characterization scans is demonstrated to be possible. Further system refinement will focus on developing a methodology to estimate a radon escape factor for site specific use. Accounting for radon escape in the top 15.24 cm of soil will allow the system to better estimate Ra-226 concentrations in soil. This is a significant advancement over the gross counting statistics used in most studies to satisfy MARSSIM survey requirements, because it will increase stakeholder confidence. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WE-AB-202-12: Voxel-Wise Analysis of Apparent Diffusion Coefficient and Perfusion Maps in Multi-Parametric MRI of Prostate Cancer

Purpose: Multi-parametric MRI (mp-MRI) is being introduced in radiotherapy (RT) of prostate cancer, including for tumour delineation in focal boosting strategies. We recently developed an image-based tumour control probability model, based on cell density distributions derived from apparent diffusion coefficient (ADC) maps. Beyond tumour volume and cell densities, tumour hypoxia is also an important determinant of RT response. Since tissue perfusion from mp-MRI has been related to hypoxia we have explored the patterns of ADC and perfusion maps, and the relations between them, inside and outside prostate index lesions. Methods: ADC and perfusion maps from 20 prostate cancer patients were used, with the prostate and index lesion delineated by a dedicated uro-radiologist. To reduce noise, the maps were averaged over a 3×3×3 voxel cube. Associations between different ADC and perfusion histogram parameters within the prostate, inside and outside the index lesion, were evaluated with the Pearson’s correlation coefficient. In the voxel-wise analysis, scatter plots of ADC vs perfusion were analysed for voxels in the prostate, inside and outside of the index lesion, again with the associations quantified with the Pearson’s correlation coefficient. Results: Overall ADC was lower inside the index lesion than in the normal prostate as opposed to ktrans that was higher inside the index lesion than outside. In the histogram analysis, the minimum ktrans was significantly correlated with the maximum ADC (Pearson=0.47; p=0.03). At the voxel level, 15 of the 20 cases had a statistically significant inverse correlation between ADC and perfusion inside the index lesion; ten of the cases had a Pearson < −0.4. Conclusion: The minimum value of ktrans across the tumour was correlated to the maximum ADC. However, on the voxel level, the ‘local’ ktrans in the index lesion is inversely (i.e. negatively) correlated to the ‘local’ ADC in most patients. Research agreement with Varian Medical Systems, not related to the work presented in this abstract.

60 APPLIED LIFE SCIENCES↗

The Solid Rocket Motor Slag Population: Results of a Radar-Based Regressive Statistical Evaluation

Solid rocket motor (SRM) slag has been identified as a potential source of man-made orbital debris. The possibility that SRMs (in addition to generating dust particles in the sub-millimeter range) may generate particles up to centimeters in size has caused concern regarding their contribution to the debris environment. Returned surfaces from space do not have sufficient area or exposure time to provide a clear picture of the SRM millimeter and centimeter debris population. Currently, radar observation is probably the only way to collect data showing the debris contribution from SRMs. Such observation is used to sample the debris environment, but it is difficult to obtain accurate orbital elements for the detected debris objects. NASA has developed several models to describe the different orbital debris populations, based on assumed debris production mechanisms to create clouds of debris objects that can be propagated in time. The NASA model, LEGEND (LEO-to-GEO Environment Debris), functions as a time-tested debris model for most debris sources. However, the current LEGEND model does not include contributions from the SRM population. An SRM model has recently been developed by NASA, based on purely theoretical details of SRM production and known SRM launches, but verification with hard data is needed. Because the detections of individual SRM objects cannot be deterministically separated from the total debris observed by radar, the validation of the SRM model can only be done by combining it with the LEGEND breakup model and comparing it with data. By applying observational constraints, the degree of SRM slag contribution to the environment may be estimated. This serves as an observationally sound method from which to calibrate a purely theoretical model into something more realistic. For this study, we use the populations observed by the Haystack radar from 1996 to present. For the SRM debris, we use a historical database of SRM launches, propellant masses, and estimated locations and times of tailoff to produce and propagate the SRM debris clouds. Comparisons with radar data from the ensuing years were made, and the SRM model was altered with respect to size and mass production of slag particles to reflect the populations estimated from the data. The result is a model SRM population that fits within the bounds of the observed environment and estimates of the production and contribution of SRM debris to the environment.

Horstman, Matthew F.↗

Galaxy clustering with photometric surveys using PDF redshift information

Here, photometric surveys produce large-area maps of the galaxy distribution, but with less accurate redshift information than is obtained from spectroscopic methods. Modern photometric redshift (photo-z) algorithms use galaxy magnitudes, or colors, that are obtained through multi-band imaging to produce a probability density function (PDF) for each galaxy in the map. We used simulated data to study the effect of using different photo-z estimators to assign galaxies to redshift bins in order to compare their effects on angular clustering and galaxy bias measurements. We found that if we use the entire PDF, rather than a single-point (mean or mode) estimate, the deviations are less biased, especially when using narrow redshift bins. When the redshift bin widths are $\Delta z=0.1$, the use of the entire PDF reduces the typical measurement bias from 5%, when using single point estimates, to 3%.

79 ASTRONOMY AND ASTROPHYSICS↗

Correlative feature analysis on FFDM

Identifying the corresponding images of a lesion in different views is an essential step in improving the diagnostic ability of both radiologists and computer-aided diagnosis (CAD) systems. Because of the nonrigidity of the breasts and the 2D projective property of mammograms, this task is not trivial. In this pilot study, we present a computerized framework that differentiates between corresponding images of the same lesion in different views and noncorresponding images, i.e., images of different lesions. A dual-stage segmentation method, which employs an initial radial gradient index (RGI) based segmentation and an active contour model, is applied to extract mass lesions from the surrounding parenchyma. Then various lesion features are automatically extracted from each of the two views of each lesion to quantify the characteristics of density, size, texture and the neighborhood of the lesion, as well as its distance to the nipple. A two-step scheme is employed to estimate the probability that the two lesion images from different mammographic views are of the same physical lesion. In the first step, a correspondence metric for each pairwise feature is estimated by a Bayesian artificial neural network (BANN). Then, these pairwise correspondence metrics are combined using another BANN to yield an overall probability of correspondence. Receiver operating characteristic (ROC) analysis was used to evaluate the performance of the individual features and the selected feature subset in the task of distinguishing corresponding pairs from noncorresponding pairs. Using a FFDM database with 123 corresponding image pairs and 82 noncorresponding pairs, the distance feature yielded an area under the ROC curve (AUC) of 0.81{+-}0.02 with leave-one-out (by physical lesion) evaluation, and the feature metric subset, which included distance, gradient texture, and ROI-based correlation, yielded an AUC of 0.87{+-}0.02. The improvement by using multiple feature metrics was statistically significant compared to single feature performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of dissipative inhomogeneous medium on the statistics of the wave intensity

One of the main theoretical points in the theory of wave propagation in random medium is the derivation of closed form equations to describe the statistics of the propagating waves. In particular, in one dimensional problems, the closed form representation of the multiple scattering effects is important since it contributes in understanding such problems like wave localization, backscattering enhancement, and intensity fluctuations. In this the propagation of plane waves in a layer of one-dimensional dissipative random medium is considered. The medium is modeled by a complex permittivity whose real part is a constant representing the absorption. The one dimensional problem is mathematically equivalent to the analysis of a transmission line with randomly perturbed distributed parameters and a single mode lossy waveguide and the results can be used to study the propagation of radio waves through atmosphere and the remote sensing of geophysical media. It is assumed the scattering medium consists of an ensemble of one-dimensional point scatterers randomly positioned in a layer of thickness L with diffuse boundaries. A Poisson impulse process with density lambda is used to model the position of scatterers in the medium. By employing the Markov properties of this process an exact closed form equation of Kolmogorov-Feller type was obtained for the probability density of the reflection coefficient. This equation was solved by combining two limiting cases: (1) when the density of scatterers is small; and (2) when the medium is weakly dissipative. A two variable perturbation method for small lambda was used to obtain solutions valid for thick layers. These solutions are then asymptotically evaluated for small dissipation. To show the effect of dissipation, the mean and fluctuations of the reflected power are obtained. The results were compared with a lossy homogeneous medium and with a lossless inhomogeneous medium and the regions where the effect of absorption is not essential were discussed.

Saatchi, Sasan S.↗