Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse shape”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.

Lee, Yong Jin↗

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

Lee, Yong Jin↗

EPR Imaging at a Few Megahertz Using SQUID Detectors

An apparatus being developed for electron paramagnetic resonance (EPR) imaging operates in the resonance-frequency range of about 1 to 2 MHz well below the microwave frequencies used in conventional EPR. Until now, in order to obtain sufficient signal-to-noise radios (SNRs) in conventional EPR, it has been necessary to place both detectors and objects to be imaged inside resonant microwave cavities. EPR imaging has much in common with magnetic resonance imaging (MRI), which is described briefly in the immediately preceding article. In EPR imaging as in MRI, one applies a magnetic pulse to make magnetic moments (in this case, of electrons) precess in an applied magnetic field having a known gradient. The magnetic moments precess at a resonance frequency proportional to the strength of the local magnetic field. One detects the decaying resonance-frequency magnetic- field component associated with the precession. Position is encoded by use of the known relationship between the resonance frequency and the position dependence of the magnetic field. EPR imaging has recently been recognized as an important tool for non-invasive, in vivo imaging of free radicals and reduction/oxidization metabolism. However, for in vivo EPR imaging of humans and large animals, the conventional approach is not suitable because (1) it is difficult to design and construct resonant cavities large enough and having the required shapes; (2) motion, including respiration and heartbeat, can alter the resonance frequency; and (3) most microwave energy is absorbed in the first few centimeters of tissue depth, thereby potentially endangering the subject and making it impossible to obtain adequate signal strength for imaging at greater depth. To obtain greater penetration depth, prevent injury to the subject, and avoid the difficulties associated with resonant cavities, it is necessary to use lower resonance frequencies. An additional advantage of using lower resonance frequencies is that one can use weaker applied magnetic fields: For example, for a resonance frequency of 1.4 MHz, one needs a magnetic flux density of 0.5 Gauss approximately the flux density of the natural magnetic field of the Earth.

Hahn, Inseob↗

A CUPID Li2100MoO4 scintillating bolometer tested in the CROSS underground facility

A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2\beta$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $\gamma$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$\sigma$) between $\gamma$($\beta$) and $\alpha$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $\mu$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2\beta$ decay in CROSS and CUPID projects.

47 OTHER INSTRUMENTATION↗

Design and demonstration of a distributed-coupling linear accelerator structure

We present a topology for linear accelerators (linacs) in which the power is distributed to the cavities through a waveguide with periodic apertures that guarantees the correct phases and amplitudes along the structure length. Unlike conventional traveling and standing-wave linacs, the presented topology allows the cavity shapes to be designed without the constraints applied to the coupling between cells to transfer power from one cell to the next. Therefore, the topology permits more degrees of freedom for the optimization of individual cavity shapes in comparison with conventional linacs. The cavity shapes can be optimized for power consumption and efficiency, and/or the manipulation of the surface fields for high gradient operation. This topology also provides a possibility for low-temperature manufacturing techniques that prevent the annealing of the material during typical brazing processes; hence, the material could retain its original properties such as hardness. We present a design and an experimental demonstration of this linac.

43 PARTICLE ACCELERATORS↗

Disruption Mitigation Solutions for Long Pulse Tokamaks (Final Technical Report)

The project "Disruption Mitigation Solutions for Long Pulse Tokamaks" was a collaborative effort between ORNL, GA, and UCSD. The main goal of the project was to study the injection of shattered cryogenic pellets (SPI) as a method of reducing wall damage from global tokamak plasma instabilities called disruptions. This work was primarily carried out in the JET tokamak in the UK. The team already had extensive experience studying PSI in the medium sized DIII-D tokamak in the US, but adding data from the larger JET tokamak enabled more confident extrapolation to the even larger planned ITER tokamak in France. Each of the collaborating institutions focused on different aspects of SPI disruption mitigation. The UCSD collaboration focused on the volume recombination of post-disruption runaway electron (RE) beams by massive hydrogen injection. Disruptions can sometimes result in the formation of toroidal (ring shaped) beams of highly energetic (relativistic) electron beams, which can cause serious local wall damage, even in present-day tokamaks. A promising method to reduce wall damage from the RE beams is to inject massive amounts of H 2 or D 2 into the beams using SPI. although the precise method by which the injected H 2 reducses RE wall damage is still being investigated, it seems clear that a necessary and required step for the reduction to occur is for the H 2 injection to cause volume recombination (free electron density reduction) of the background cold plasma surrounding the fast electron beam. The UCSD collaboration focused on answering the question of if this recombination could be achievable in the future reactor-size tokamak ITER using realistic levels of H 2 injection. A model capturing the most essential physics was developed and was constrained using both DIII-D and JET data. This model was then used to extrapolate to ITER. It was predicted that RE beam recombination should be achievable in ITER, although in the worst-case scenari (a 10 MA Re beam in ITER), recombination is barely achieved within the maximum allowed levels of H 2 injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimating Temperature Rise Due to Flashlamp Heating Using Irreversible Temperature Indicators

One of the nondestructive thermography inspection techniques uses photographic flashlamps. The flashlamps provide a short duration (about 0.005 sec) heat pulse. The short burst of energy results in a momentary rise in the surface temperature of the part. The temperature rise may be detrimental to the top layer of the part being exposed. Therefore, it is necessary to ensure the nondestructive nature of the technique. Amount of the temperature rise determines whether the flashlamp heating would be detrimental to the part. A direct method for the temperature measurement is to use of an infrared pyrometer that has much shorter response time than the flash duration. In this paper, an alternative technique is given using the irreversible temperature 'indicators. This is an indirect technique and it measures the temperature rise on the irreversible temperature indicators and computes the incident heat flux. Once the heat flux is known, the temperature rise on the part can be computed. A wedge shaped irreversible temperature indicator for measuring the heat flux is proposed. A procedure is given to use the wedge indicator.

Koshti, Ajay M.↗

The effect of annealing on optical transmittance and structure of ZLANI fluorozirconate glass thin films

In this work, we report the effect of thermal annealing on structure, composition, optical transmittance and thickness of a novel fluorozirconate glass (ZLANI) containing Zr, La, Al, Na and In fluorides. In this work, pulsed laser depo- sition was used to grow thin films of ZLANI, and thermal annealing at different temperatures was performed on the films. Annealing did not change the composition, but a clear structural evolution of the ZLANI glass was observed by transmission electron microscopy (TEM), showing that we can control microstructure independent of composition. An increase in transmittance after the film was subject to a 100 °C thermal anneal was ascribed to the removal of defects and structural relaxation in the amorphous state. Following an anneal of 200 °C, the transmittance decreases due to heterogeneous formation of crystalline nuclei and changes in the local bonding. After the final annealing at 300 °C, a wider-scale crystallization occurred, with some major crystal phases formed as Zr 2 F 8 (H 2 O) 6 and ZrO 2 , which alters the shape of the transmittance curve. The crystalline content of the crystal phases that form in the annealed films was quantified using hollow cone dark field TEM imaging. The 100 °C or 200 °C annealing decreases the film thickness by inducing structural relaxation and densification of the amorphous films, while the thickness increase of the 300 °C annealed film resulted from the formed large crystals. These results provide insights for the design of multilayer nanocomposites with a ZLANI glass matrix, which have potential applications as up-/down-conversion luminescent materials and X-ray storage phosphors.

36 MATERIALS SCIENCE↗

New Design for Low-Mode Asymmetry Mitigation in Inertial Confinement Fusion Implosions

Radiation flux symmetry in laser-irradiated hohlraum environments is difficult to model and control and relies on the details of plasma evolution and laser energy deposition in the harsh plasma-filled hohlraum over the duration of the laser pulse. This study presents a conceptual design and assesses the feasibility of using lasers to create a drive where the implosion symmetry relies mainly on radiation transport. In this design lasers irradiate the ends of a capsule containing hohlraum that are shielded from the view of the capsule. This configuration enables the use of frequency doubled light that has a higher power and energy threshold for the current capability of NIF, up to 670TW and ~3.5 MJ. We estimate, using VISRAD benchmarked against HYDRA calculations, that the same drive conditions that are currently being achieved in hybridE experiments at the NIF 270-290 at the equator can be reached in this new geometry and large 6.4 mm diameter hohlraums. The radiation drive asymmetries in this design can be mitigated by shimming the capsule ablator thickness or through tailoring the shape of the shielding to the laser spots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Land altimetry using satellite data from the GEOSAT sea altimeter

Several techniques are proposed or assessed from the GEOSAT sea altimeter, and changes are recommended in future RADAR altimeters. The first technique tried was to cross-correlate each waveform with the preceding one. Then the position giving the maximum correlation was taken as the correct placement of the new waveform in its data window. The resulting altitude profile was slightly more variable than that of the on-board tracker over flat rock (Salar de Uyuni), so apparently successive waveforms are too dissimilar to correlate. When cross-correlation failed, compensation was made for averaging. Raw waveforms are averaged in groups of 100 and it is these average waveforms which are available for ground processing. But while the 100 are being received, the window position is moved in time, at different constant rates for the first 50 and last 50. Assuming an unchanging waveform and a single window rate for the 100, first and last waveforms were obtained. Averaging their half-height arrival times gave an altitude profile similar to the median and centroid methods. The variability of this altitude profile suggests that even raw waveforms in a group of 100 may be too dissimilar to correlate. In other techniques, the pulse was judged to have arrived when one of these criteria was met: the wave amplitude meets a certain absolute threshold; wave amplitude meets a certain relative threshold; certain fraction of the area of the waveform has passed; and centroid of the waveform has passed. All methods gave altitude profiles at least as variable as the on-board tracker, and all were biased at least 0.5 meter to low altitudes, except the threshold detector. The threshold detector can be filtered spatially to resemble the on-board tracker, and perhaps it could be implemented without feedback. For operating over land, these changes are recommended in future altimeters: The window should not move while raw waveforms are being averaged; some of the raw waveforms should be telemetered to earth for study, placing the waveform in the window should allow for shape variety; and some form of threshold detector might be used to find the signal and place it.

Luft, Philip E.↗

Optimal Spatial Separation of High-Order Harmonics from Infrared Driving Lasers with an Annular Beam in the Overdriven Regime

We study high-order harmonic generation (HHG) with an annularly shaped high-power, high-repetition-rate laser. In this work we investigate how the spatial separation (or divergence) of the incident laser and the generated high-order harmonics depends on the gas pressure when the laser intensity is in the overdriven regime. It is shown that, when the cone size of the incident annular beam is relatively large, the resulting harmonics are highly collimated along the propagation axis and are spatially separated from the incident beam. Under the overdriven condition, dynamic phase matching favors HHG emissions from short-trajectory electrons that are efficiently built up in the second half of the gas medium. We verify that using an annular beam is a simple and effective method for separating the intense incident infrared laser from the generated high harmonics. Such high-flux and low-divergence light pulses are expected to be powerful sources in the laboratory for ultrafast probing of electron dynamics.

47 OTHER INSTRUMENTATION↗

Software-Defined Ultrasonic Communication System Based on Time-reversal Signal Processing

Ultrasonic communication through solid channels suffers from channel dispersion, attenuation, and multipath effect. For example, in elbow shape pipes or complex structures, the elastic waves are reflected and reverberated in multipath resulting in a major dispersion of the signals. In solid channels such as flat bar, multipath propagation is the main reason for bit-wavelet spreading and intersymbol interference (ISI). The conventional modulation method like OOK (on-off-keying) or PSK (phase-shift-keying) fails to provide a useful Signal-to-Noise Ratio (SNR). Time-reversal (TR) signal processing method is a promising technique that can compress the spreading of the bit-wavelet and strengthen the peak signal energy on the receiver. In this study, Finite Element Analysis (FEA) using ABAQUS software tools is used to characterize the bit-wavelet spreading effect caused by dispersive communication channels. Also, this study presents the impact of TR ultrasonic communication as a function of excitation pulse width, channel length, and carrier frequency through a flat-bar channel. A Software-Defined System-on-Chip (SD-SoC) platform is examined as a viable solution for the low-complexity and energy-efficient ultrasonic communication system. The proposed TR based SD-SoC ultrasonic communication system can make full use of signal dispersion for peak performance by minimizing the ISI within a dispersive and reverberant metal channel.

FEM simulation↗

A unique method to study acoustic transmission through ducts using signal synthesis and averaging of acoustic pulses

An acoustic impulse technique using a loudspeaker driver is developed to measure the acoustic properties of a duct/nozzle system. A signal synthesis method is used to generate a desired single pulse with a flat spectrum. The convolution of the desired signal and the inverse Fourier transform of the reciprocal of the driver's response are then fed to the driver. A signal averaging process eliminates the jet mixing noise from the mixture of jet noise and the internal noise, thereby allowing very low intensity signals to be measured accurately, even for high velocity jets. A theoretical analysis is carried out to predict the incident sound field; this is used to help determine the number and locations of the induct measurement points to account for the contributions due to higher order modes present in the incident tube method. The impulse technique is validated by comparing experimentally determined acoustic characteristics of a duct-nozzle system with similar results obtained by the impedance tube method. Absolute agreement in the comparisons was poor, but the overall shapes of the time histories and spectral distributions were much alike.

Salikuddin, M.↗

High reliability megawatt transformer/rectifier

The goal of the two phase program is to develop the technology and design and fabricate ultralightweight high reliability DC to DC converters for space power applications. The converters will operate from a 5000 V dc source and deliver 1 MW of power at 100 kV dc. The power weight density goal is 0.1 kg/kW. The cycle to cycle voltage stability goals was + or - 1 percent RMS. The converter is to operate at an ambient temperature of -40 C with 16 minute power pulses and one hour off time. The uniqueness of the design in Phase 1 resided in the dc switching array which operates the converter at 20 kHz using Hollotron plasma switches along with a specially designed low loss, low leakage inductance and a light weight high voltage transformer. This approach reduced considerably the number of components in the converter thereby increasing the system reliability. To achieve an optimum transformer for this application, the design uses four 25 kV secondary windings to produce the 100 kV dc output, thus reducing the transformer leakage inductance, and the ac voltage stresses. A specially designed insulation system improves the high voltage dielectric withstanding ability and reduces the insulation path thickness thereby reducing the component weight. Tradeoff studies and tests conducted on scaled-down model circuits and using representative coil insulation paths have verified the calculated transformer wave shape parameters and the insulation system safety. In Phase 1 of the program a converter design approach was developed and a preliminary transformer design was completed. A fault control circuit was designed and a thermal profile of the converter was also developed.

Zwass, Samuel↗

Radiation driven Hohlraum using 2 ω for ICF implosions at the NIF

Radiation flux symmetry in laser-irradiated Hohlraum environments is difficult to model and control and relies on the details of plasma evolution and laser energy deposition in the harsh plasma-filled Hohlraum over the duration of the laser pulse. This study presents a conceptual design and assesses the feasibility of using lasers to create a radiation drive where the implosion symmetry relies mainly on radiation transport. In this design, the ends of a capsule containing Hohlraum are irradiated by drive laser beams that are shielded from the view of the capsule. This configuration enables the use of frequency doubled light that has a higher power and energy threshold for the current capability of NIF, up to 670 TW and ∼3.5 MJ. We estimate, using VISRAD benchmarked against HYDRA calculations, that the same drive conditions that are currently being achieved in hybridE experiments at the NIF 270–290 at the equator can be reached in this new geometry and large 6.4 mm diameter Hohlraums. The radiation drive asymmetries in this design can be mitigated by shimming the capsule ablator thickness or through tailoring the shape of the shielding to the laser spots.

Kritcher, A. L. (ORCID:0000000296941088)↗

Lunar and Planetary Science XXXV: Asteroids, Meteors, Comets

Reports included:Long Term Stability of Mars Trojans; Horseshoe Asteroids and Quasi-satellites in Earth-like Orbits; Effect of Roughness on Visible Reflectance Spectra of Planetary Surface; SUBARU Spectroscopy of Asteroid (832) Karin; Determining Time Scale of Space Weathering; Change of Asteroid Reflectance Spectra by Space Weathering: Pulse Laser Irradiation on Meteorite Samples; Reflectance Spectra of CM2 Chondrite Mighei Irradiated with Pulsed Laser and Implications for Low-Albedo Asteroids and Martian Moons; Meteorite Porosities and Densities: A Review of Trends in the Data; Small Craters in the Inner Solar System: Primaries or Secondaries or Both?; Generation of an Ordinary-Chondrite Regolith by Repetitive Impact; Asteroid Modal Mineralogy Using Hapke Mixing Models: Validation with HED Meteorites; Particle Size Effect in X-Ray Fluorescence at a Large Phase Angle: Importance on Elemental Analysis of Asteroid Eros (433); An Investigation into Solar Wind Depletion of Sulfur in Troilite; Photometric Behaviour Dependent on Solar Phase Angle and Physical Characteristics of Binary Near-Earth-Asteroid (65803) 1996 GT; Spectroscopic Observations of Asteroid 4 Vesta from 1.9 to 3.5 micron: Evidence of Hydrated and/or Hydroxylated Minerals; Multi-Wavelength Observations of Asteroid 2100 Ra-Shalom: Visible, Infrared, and Thermal Spectroscopy Results; New Peculiarities of Cometary Outburst Activity; Preliminary Shape Modeling for the Asteroid (25143) Itokawa, AMICA of Hayabusa Mission; Scientific Capability of MINERVA Rover in Hayabusa Asteroid Mission; Characteristics and Current Status of Near Infrared Spectrometer for Hayabusa Mission; Sampling Strategy and Curation Plan of Hayabusa Asteroid Sample Return Mission; Visible/Near-Infrared Spectral Properties of MUSES C Target Asteroid 25143 Itokawa; Calibration of the NEAR XRS Solar Monitor; Modeling Mosaic Degradation of X-Ray Measurements of 433 Eros by NEAR-Shoemaker; Scattered Light Remediation and Recalibration of near Sheomaker s NIS Global Dataaset at 433 Eros; Evaluation of Preparation and Measuring Techniques for Interplanetary Dust Particles for the MIDAS Experiment on Rosetta; Chiron: a Proposed Remote Sensing Prompt Gamma Ray Activation Analysis Instrument for a Nuclear Powered Prometheus Mission;From Present Surveying to Future Prospecting of the Asteroid Belt; Asteroid Physical Properties Probe Microgravity Testing of a Surface Sampling System for Sample Return from Small Solar System Bodies;and Penetrator Coring Apparatus for Cometary Surfaces.

Source record↗

Mechanical Design of the PIP-II ORBUMP Pulsed Dipole Magnet

The Proton Improvement Plan-II (PIP-II) is a vital upgrade to Fermilab's accelerator complex. The upgrade is designed to power the world s most intense high-energy neutrino beam in future experiments. The magnet pulse repetition rate of the PIP-II injection system is being upgraded from 15 Hz to 20 Hz and requires a roughly 30% increase in the magnetic field of the new Orbital Bump (ORBUMP) magnets in the Booster. The magnet is secured in a vacuum box and the core is made up of 0.127 mm thick, low carbon steel laminations with a C-5 inorganic coating. The core is clamped using external tie bars welded to the core end plates. ANSYS Finite Element Analysis (FEA) was used to evaluate the clamping design to minimize the deflection of the core post welding of the tie bars. The water-cooled single turn coil is electrically isolated from the core using virgin PEEK insulating material in the gap. An investigation into the high voltage performance of the virgin PEEK insulator was conducted. The design of the coil which shapes the magnetic field by acting as the pole tips is critical for the integrated field homogeneity. The coil manufacturing tolerances and fabrication techniques were evaluated to ensure the magnetic properties of the magnet could be obtained. The ORBUMP magnet mechanical design is presented in this paper.

Karas, Dino [Fermilab] (ORCID:0000000304340670)↗

Propagation velocities of laser-produced plasmas from copper wire targets and water droplets

Experiments were performed to determine the plasma propagation velocities resulting from KrF laser irradiation of copper wire target (75 microns diameter) and water droplets (75 microns diameter) at irradiance levels ranging from 25 to 150 GW/sq cm. Plasma propagation velocities were measured using a streak camera system oriented orthogonally to the high-energy laser propagation axis. Plasma velocities were studied as a function of position in the focused beam. Results show that both the shape of the plasma formation and material removal from the copper wire are different and depend on whether the targets are focused or slightly defocused (approximately = 0.5 mm movement in the beam axis). Plasma formation and its position relative to the target is an important factor in determining the practical focal point during high-energy laser interaction with materials. At irradiance of 100 GW/sq cm, the air plasma has two weak-velocity components which propagate toward and away from the incident laser while a strong-velocity component propagates away from the laser beam as a detonation wave. Comparison of the measured breakdown velocities (in the range of 2.22-2.27 x 10(exp 5) m/s) for air and the value calculated by the nonlinear breakdown wave theory at irradiance of 100 GW/sq cm showed a quantitative agreement within approximately 50% while the linear theory and Gaussian pulse theory failed. The detonation wave velocities of plasma generated from water droplets and copper wire targets for different focused cases were measured and analyzed theoretically. The propagation velocities of laser-induced plasma liquid droplets obtained by previous research are compared with current work.

Song, Kyo-Dong↗