Search NASA⌕ Search

SEARCH · Search NASA

Results for “randomized methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Long-term missing value imputation for time series data using deep neural networks

We present an approach that uses a deep learning model, in particular, a MultiLayer Perceptron, for estimating the missing values of a variable in multivariate time series data. We focus on filling a long continuous gap (e.g., multiple months of missing daily observations) rather than on individual randomly missing observations. Our proposed gap filling algorithm uses an automated method for determining the optimal MLP model architecture, thus allowing for optimal prediction performance for the given time series. We tested our approach by filling gaps of various lengths (three months to three years) in three environmental datasets with different time series characteristics, namely daily groundwater levels, daily soil moisture, and hourly Net Ecosystem Exchange. We compared the accuracy of the gap-filled values obtained with our approach to the widely used R-based time series gap filling methods ImputeTS and mtsdi. The results indicate that using an MLP for filling a large gap leads to better results, especially when the data behave nonlinearly. Thus, our approach enables the use of datasets that have a large gap in one variable, which is common in many long-term environmental monitoring observations.

97 MATHEMATICS AND COMPUTING↗

In vivo study of breast carcinoma radiosensitization by targeting eIF4E

Highlights: Black-Right-Pointing-Pointer eIF4E is associated with the formation and progression for breast cancer. Black-Right-Pointing-Pointer pSecX-t4EBP1 can downregulated the expression of eIF4E in direct binding. Black-Right-Pointing-Pointer We transfected pSecX-t4EBP1 into a mouse xenograft model. Black-Right-Pointing-Pointer It can significantly inhibit tumor growth and enhance the radiosensitivity. Black-Right-Pointing-Pointer The possible mechanism is downregulation of HIF-1{alpha} expression. -- Abstract: Background: Eukaryotic initiation factor eIF4E, an important regulator of translation, plays a crucial role in the malignant transformation, progression and radioresistance of many human solid tumors. The overexpression of this gene has been associated with tumor formation in a wide range of human malignancies, including breast cancer. In the present study, we attempted to explore the use of eIF4E as a therapeutic target to enhance radiosensitivity for breast carcinomas in a xenograft BALB/C mice model. Materials and methods: Ninety female BALB/C mice transfected with EMT-6 cells were randomly divided into six groups: control, irradiation (IR), pSecX-t4EBP1, pSecX-t4EBP1 + irradiation, pSecX and pSecX + irradiation. At the end of the experiments, all mice were sacrificed, the xenografts were harvested to measure the tumor volume and mass, and the tumor inhibition rates were calculated. Apoptosis was detected with a flow cytometric assay. Immunohistochemistry was used to detect the expression of HIF-1{alpha}. Results: The xenografts in pSecX-t4EBP1 mice showed a significantly delayed growth and smaller tumor volume, with a higher tumor inhibition rate compared with the control and pSecX groups. A similar result was obtained in the pSecX-t4EBP1 + IR group compared with IR alone and pSecX + irradiation. The expression of HIF-1{alpha} in the tumor cells was significantly decreased, while the apoptosis index was much higher. Conclusions: pSecX-t4EBP1 can significantly inhibit tumor growth and enhance the radiosensitivity of breast carcinoma xenografts in BALB/C mice. This is possibly associated with the downregulation of HIF-1{alpha} expression, which suggests that pSecX-t4EBP1 may serve as an ideal molecular target for the radiosensitization of breast carcinoma.

60 APPLIED LIFE SCIENCES↗

Patterns of Radiation Therapy Practice for Patients Treated for Intact Cervical Cancer in 2005 to 2007: A Quality Research in Radiation Oncology Study

Purpose: To assess practice patterns and compliance with clinical performance measures for radiation therapy (RT) for patients with intact carcinoma of the cervix. Methods and Materials: Trained research associates reviewed the records of 261 randomly selected patients who received RT for cervix carcinoma between 2005 and 2007 from 45 facilities randomly selected after stratification by practice type. National estimates of patient and treatment characteristics were calculated from survey data using SUDAAN statistical software. Results: From the survey data, we estimated that only 8% of US facilities treated on average more than 3 eligible patients per year. No small or medium nonacademic facilities in the survey treated more than 3 eligible patients per year. Approximately 65.5% of patients began treatment in a facility that treated 3 or fewer eligible patients per year. Although 87.5% of patients had brachytherapy as part of their treatment, the proportion treated with external beam RT only was about double that estimated from the 1996 to 1999 survey. The use of high-dose-rate brachytherapy sharply increased, particularly in small nonacademic facilities. Overall, patients treated in nonacademic facilities were more likely to have incomplete or protracted treatment; 43% of patients treated in small nonacademic facilities did not have treatment completed within 10 weeks. Also, patients treated in facilities that treated 3 or fewer eligible patients per year were significantly less likely to receive concurrent chemotherapy than were patients treated in other facilities. Conclusion: Survey results indicate a disturbingly high rate of noncompliance with established criteria for high-quality care of patients with cervical cancer. Noncompliance rates are particularly high in nonacademic facilities, especially those that treat relatively few patients with intact cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Monte Carlo volumetric-ray-casting estimator for global fluence tallies on GPUs

A Monte Carlo fluence estimator has been designed to take advantage of the computational power of graphical processing units (GPUs). This new estimator, termed the volumetric-ray-casting estimator, is an extension of the expectation estimator. It can be used as a replacement of the track-length estimator for the estimation of global fluence. Calculations for this estimator are performed on the GPU while the Monte Carlo random walk is performed on the central processing unit (CPU). This method lowers the implementation cost for GPU acceleration of existing Monte Carlo particle transport codes as there is little modification of the particle history logic flow. Three test problems have been evaluated to assess the performance of the volumetric-ray-casting estimator for neutron transport on GPU hardware in comparison to the standard track-length estimator on CPU hardware. Evaluation of neutron transport through air in a criticality accident scenario showed that the volumetric-ray-casting estimator achieved 23 times the performance of the track-length estimator using a single core CPU paired with a GPU and 15 times the performance of the track-length estimator using an eight core CPU paired with a GPU. Finally, simulation of a pressurized water reactor fuel assembly showed that the performance improvement was 6 times within the fuel and 7 times within the control rods using an eight core CPU paired with a single GPU.

74 ATOMIC AND MOLECULAR PHYSICS↗

Self-testing of a single quantum system from theory to experiment

Abstract Self-testing allows one to characterise quantum systems under minimal assumptions. However, existing schemes rely on quantum nonlocality and cannot be applied to systems that are not entangled. Here, we introduce a robust method that achieves self-testing of individual systems by taking advantage of contextuality. The scheme is based on the simplest contextuality witness for the simplest contextual quantum system—the Klyachko-Can-Binicioğlu-Shumovsky inequality for the qutrit. We establish a lower bound on the fidelity of the state and the measurements as a function of the value of the witness under a pragmatic assumption on the measurements. We apply the method in an experiment on a single trapped 40 Ca + using randomly chosen measurements and perfect detection efficiency. Using the observed statistics, we obtain an experimental demonstration of self-testing of a single quantum system.

Physics↗

Photoelectron circular dichroism in the multiphoton ionization by short laser pulses. I. Propagation of single-active-electron wave packets in chiral pseudo-potentials

A theoretical method to study the angle-resolved multiphoton ionization of polyatomic molecules is developed. It is based on the time-dependent formulation of the Single Center (TDSC) method and consists in the propagation of single-active-electron wave packets in the effective molecular potentials in the presence of intense laser pulses. For this purpose, the time-dependent Schrödinger equation for one electron, moving in a molecular field and interacting with an arbitrary laser pulse, is solved in spherical coordinates by an efficient numerical approach. As a test, the method is applied to the one- and two-photon ionizations of a model methane-like chiral system by circularly polarized short intense high-frequency laser pulses. Thereby, we analyze the photoelectron circular dichroism (PECD) in the momentum distribution. The considered model application illustrates the capability of the TDSC method to study multiphoton PECD in fixed-in-space and randomly oriented chiral molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transferring predictions of formation energy across lattices of increasing size*

In this study, we show the transferability of graph convolutional neural network (GCNN) predictions of the formation energy of the nickel-platinum solid solution alloy across atomic structures of increasing sizes. The original dataset was generated with the large-scale atomic/molecular massively parallel simulator using the second nearest-neighbor modified embedded-atom method empirical interatomic potential. Geometry optimization was performed on the initially randomly generated face centered cubic crystal structures and the formation energy has been calculated at each step of the geometry optimization, with configurations spanning the whole compositional range. Using data from various steps of the geometry optimization, we first trained our open-source, scalable implementation of GCNN called HydraGNN on a lattice of 256 atoms, which accounts well for the short-range interactions. Using this data, we predicted the formation energy for lattices of 864 atoms and 2048 atoms, which resulted in lower-than-expected accuracy due to the long-range interactions present in these larger lattices. We accounted for the long-range interactions by including a small amount of training data representative for those two larger sizes, whereupon the predictions of HydraGNN scaled linearly with the size of the lattice. Therefore, our strategy ensured scalability while reducing significantly the computational cost of training on larger lattice sizes.

36 MATERIALS SCIENCE↗

Simulation of Rutherford backscattering spectrometry from arbitrary atom structures

Rutherford backscattering spectrometry in a channeling direction (RBS/C) is a powerful tool for analysis of the fraction of atoms displaced from their lattice positions. However, it is in many cases not straightforward to analyze what is the actual defect structure underlying the RBS/C signal. To reveal insights of RBS/C signals from arbitrarily complex defective atomic structures, we develop in this paper a method for simulating the RBS/C spectrum from a set of arbitrary read-in atom coordinates (obtained, e.g., from molecular dynamics simulations). We apply the developed method to simulate the RBS/C signals from Ni crystal structures containing randomly displaced atoms, Frenkel point defects, and extended defects, respectively. The RBS/C simulations show that, even for the same number of atoms in defects, the RBS/C signal is much stronger for the extended defects. Finally, comparison with experimental results shows that the disorder profile obtained from RBS/C signals in ion-irradiated Ni is due to a small fraction of extended defects rather than a large number of individual random atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CHARACTERISTICS OF CYCLE-TO-CYCLE COMBUSTION VARIABILITY AT PARTIAL-BURN LIMITED AND MISFIRE LIMITED SPARK TIMING UNDER HIGHLY DILUTED CONDITIONS

Diluted combustion with exhaust gas recirculation (EGR) has been widely employed to improve the fuel economy of spark ignition engines. The combustion kinetics, however, are affected and the flame propagation speed is decreased. In order to compensate for this adverse effect, the spark timing needs to be recalibrated to achieve maximum brake torque (MBT). At high levels of EGR dilution, the spark timing is constrained by two ignition limits: 1) the partial-bum limit where the spark timing is retarded from MBT and 2) the misfire limit where the spark timing is too advanced. This work uses a probabilistic framework to capture the differences between both ignition limits. In particular, it introduces the concept of a nominal indicated mean effective pressure (IMEP) distribution based on the stochastic properties of the cycle-to-cycle variability (CCV) at nominal stable conditions. By defining a nominal band where fully burned cycles occur with high probability, we introduce a cycle classification method that can be used to 1) determine the level of randomness of misfire and partial-burn events, and 2) measure CCV. The new CCV metric based on the density of the nominal band is compared with the traditional coefficient of variation of IMEP (CoVIMEP). It is shown that the nominal band concept, together with the CoVIMEP, can help to discern between partial-burn limited and misfire limited conditions. Furthermore, the Kullback-Leibler divergence is used to demonstrate that the IMEP distribution is significantly different between nominal and partial-burn/misfire limited conditions. Experiments are carried at various EGR levels and spark timings while recoding in-cylinder pressure at steady state. Although the emphasis of this work is to characterize the differences of both ignition limits from a probabilistic point of view, similarities between partial-burn cycles at either limiting conditions are also discussed.

Maldonado, Bryan↗

SU-F-I-03: Correction of Intra-Fractional Set-Up Errors and Target Coverage Based On Cone-Beam Computed Tomography for Cervical Cancer Patients

Purpose: The purpose of this study is to investigate the patient set-up error and interfraction target coverage in cervical cancer using image-guided adaptive radiotherapy (IGART) with cone-beam computed tomography (CBCT). Methods: Twenty cervical cancer patients undergoing intensity modulated radiotherapy (IMRT) were randomly selected. All patients were matched to the isocenter using laser with the skin markers. Three dimensional CBCT projections were acquired by the Varian Truebeam treatment system. Set-up errors were evaluated by radiation oncologists, after CBCT correction. The clinical target volume (CTV) was delineated on each CBCT, and the planning target volume (PTV) coverage of each CBCT-CTVs was analyzed. Results: A total of 152 CBCT scans were acquired from twenty cervical cancer patients, the mean set-up errors in the longitudinal, vertical, and lateral direction were 3.57, 2.74 and 2.5mm respectively, without CBCT corrections. After corrections, these were decreased to 1.83, 1.44 and 0.97mm. For the target coverage, CBCT-CTV coverage without CBCT correction was 94% (143/152), and 98% (149/152) with correction. Conclusion: Use of CBCT verfication to measure patient setup errors could be applied to improve the treatment accuracy. In addition, the set-up error corrections significantly improve the CTV coverage for cervical cancer patients.

60 APPLIED LIFE SCIENCES↗

SU-F-T-421: Dosimetry Change During Radiotherapy and Dosimetry Difference for Rigid and Deformed Registration in the Mid-Thoracic Esophageal Carcinoma

Purpose: This study aimed to analyze dosimetry changes during radiotherapy for the mid-thoracic esophageal carcinoma, and investigate dosimetry difference between rigid and deformed registration. Methods: Twelve patients with primary middle thoracic esophageal carcinoma were selected randomly. Based on first CT scanning of each patient, plans-o were generated by experience physicists. After 20 fractions treatment, the corresponding plans-re were created with second CT scanning. And then, these two CT images were rigid and deformed registration respectively, and the dose was accumulated plan-o with plan-re. The dosimetry variation of these plans (plan-o: with 30 fractions, plan-rig: the accumulated dose with rigid registration and plan-def: the accumulated dose with deformed registration) were evaluated by paired T-test. Results: The V20 value of total lung were 32.68%, 30.3% and 29.71% for plan-o, plan-rig and plan-def respectively. The mean dose of total lung was 17.19 Gy, 16.67 Gy and 16.51 Gy for plan-o plan-rig and plan-def respectively. There were significant differences between plan-o and plan-rig or plan-def for both V20 and mean dose of total lung (with p= 0.003, p= 0.000 for V20 and p=0.008, p= 0.000 for mean dose respectively). There was no significant difference between plan-rig and plan-def (with p=0.118 for V20 and p=0.384 for mean dose). The max dose of spinal-cord was 41.95 Gy, 41.48 Gy and 41.4 Gy for plan-o, plan-rig and plan-def respectively. There were no significant differences for the max dose of spinal-cord between these plans. Conclusion: The target volume changes and anatomic position displacement of mid-thoracic esophageal carcinoma should not be neglected in clinics. These changes would cause overdose in normal tissue. Therefore, it is necessary to have another CT scanning and re-plan during the mid-thoracic esophageal carcinoma radiotherapy. And the dosimetry difference between rigid and deformed fusions was not found in this study.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-03: Atlas-Based Algorithms with Local Registration-Goodness Weighting for MRI-Driven Electron Density Mapping

Purpose: To develop image-analysis algorithms to synthesize CT with accurate electron densities for MR-only radiotherapy of head & neck (H&N) and pelvis anatomies. Methods: CT and 3T-MRI (Philips, mDixon sequence) scans were randomly selected from a pool of H&N (n=11) and pelvis (n=12) anatomies to form an atlas. All MRIs were pre-processed to eliminate scanner and patient-induced intensity inhomogeneities and standardize their intensity histograms. CT and MRI for each patient were then co-registered to construct CT-MRI atlases. For more accurate CT-MR fusion, bone intensities in CT were suppressed to improve the similarity between CT and MRI. For a new patient, all CT-MRI atlases are deformed onto the new patients’ MRI initially. A newly-developed generalized registration error (GRE) metric was then calculated as a measure of local registration accuracy. The synthetic CT value at each point is a 1/GRE-weighted average of CTs from all CT-MR atlases. For evaluation, the mean absolute error (MAE) between the original and synthetic CT (generated in a leave-one-out scheme) was computed. The planning dose from the original and synthetic CT was also compared. Results: For H&N patients, MAE was 67±9, 114±22, and 116±9 HU over the entire-CT, air and bone regions, respectively. For pelvis anatomy, MAE was 47±5 and 146±14 for the entire and bone regions. In comparison with MIRADA medical, an FDA-approved registration tool, we found that our proposed registration strategy reduces MAE by ∼30% and ∼50% over the entire and bone regions, respectively. GRE-weighted strategy further lowers MAE by ∼15% to ∼40%. Our primary dose calculation also showed highly consistent results between the original and synthetic CT. Conclusion: We’ve developed a novel image-analysis technique to synthesize CT for H&N and pelvis anatomies. Our proposed image fusion strategy and GRE metric help generate more accurate synthetic CT using locally more similar atlases (Support: Philips Healthcare). The research is supported by Philips HealthCare.

60 APPLIED LIFE SCIENCES↗

Sliced-Inverse-Regression--Aided Rotated Compressive Sensing Method for Uncertainty Quantification

Compressive-sensing-based uncertainty quantification methods have become a pow- erful tool for problems with limited data. In this paper, we use the sliced inverse regression (SIR) method to provide an initial guess for the alternating direction method, which is used to enhance sparsity of the Hermite polynomial expansion of stochastic state variables. The sparsity improvement increases both the efficiency and accuracy of the compressive-sensing-based uncertainty quantification method. We demonstrate that the initial guess from SIR is more suitable for the cases when the available data is very limited (Algorithm 4). We also propose another algorithm (Algorithm 5) that performs dimension reduction first with sliced inverse regression, then constructs a Hermite polynomial expansion of the reduced model. This method allows us to approximate the statistics accurately with even less available data. Both methods are non-intrusive and require no a priori information of the sparsity of the system. We demonstrate the effectiveness of these two methods (Algorithms 4 and 5) using problems with up to 500 random dimensions.

Yang, Xiu↗

A Systematic Review and Meta-Analysis of Tai Chi Training in Cardiorespiratory Fitness of Elderly People

Objectives. The purpose of this study was to investigate the influence of Tai Chi on cardiorespiratory fitness (CRF) in elderly people using meta-analysis. Methods. This study used seven electronic databases and data retrieved from randomized controlled trials (RCTs) investigating the role of Tai Chi on CRF in the elderly. All these 24 RCTs were screened and selected from 7 literature databases. The Stata 11.2 software (StataCorp, USA) was used for the meta-analysis, subgroup analysis, and bias test, while the Cochrane Collaboration’s tool was used for the assessment of the risk of bias (RoB). 4 researchers independently participated in sample selection, data extraction, and RoB assessment. Results. Following the inclusion criteria, 24 eligible studies were included in our analysis. The meta-analysis indicated that Tai Chi practice significantly increased the maximum rate of oxygen consumption (VO2 max) (weighted mean difference (WMD) = 3.76, 95% CI: 1.25 to 6.26, P < 0.1 ), leading to an overall reduction in the heart rate (HR) (WMD = −1.84, 95% CI: −2.04 to −1.63, P ≤ 0.001 ) and an increase in the O2 pulse (WMD = 0.94, 95% CI: 0.60 to 1.28, P ≤ 0.001 ) in individuals who practiced Tai Chi regularly compared with those who did not. The subgroup analysis suggested that overall in those who practiced Tai Chi, males (WMD = 1.48, 95% CI: 0.85 to 2.12, P ≤ 0.001 ) had higher O2 pulse than females (WMD = 0.73, 95% CI: 0.33 to 1.12, P ≤ 0.001 ). The subgroup analysis also showed an increase in the vital capacity (VC) (WMD = 316.05, 95% CI: 239.74 to 392.35, P ≤ 0.001 ) in individuals practicing Tai Chi. When the samples were further stratified by Tai Chi practicing time, the subgroup analysis suggested that individuals practicing Tai Chi over a period of 24 weeks showed no significant difference in VC (WMD = 82.95, 95% CI: -98.34 to 264.23, P = 0.370 ), while those practicing Tai Chi over a period of 48 weeks showed a significant increase (WMD = 416.62, 95% CI: 280.68 to 552.56, P ≤ 0.001 ). Furthermore, the subgroup analysis demonstrated that the increase in VC is significantly correlated with the Tai Chi practicing time (WMD = 344.97, 95% CI: 227.88 to 442.06, P ≤ 0.001 ). Conclusion. Regular Tai Chi practice could improve the CRF in the elderly, as indicated by significant improvement in indicators including VO2max, O2pulse, VC, and HR. However, gender and practice time might influence the overall beneficial outcomes.

Tan, Tianyang↗

hiposa v0.1.0

Fast construction of hierarchical N-dimensional experimental design. The software allows construction of sampling strategies that are self-avoiding, tunable in resolution in N dimensions. This code is a drop-in replacement for seeding optimization runs often performed using uniform random sampling. The hierarchical approach allows for a rapid, top down method for construction the most effective design that drives towards a global optimum.

Zwart, PetrusH [Lawrence Berkeley National Laborat↗

Fast Computational Algorithms for Partial Differential Equations and Uncertainty Quantifications

This project concerned the construction, testing and analysis of computational algorithms for solving parameterized and stochastic partial differential equations. The study and understanding of equations of this type is of fundamental importance in numerous engineering and scientific applications. Examples include simulation of plasma dynamics in models of electric propulsion and nuclear fusion, simulation of multiphase flows, such as the flow of water, gas and oil in reservoirs, and structural analysis of the dependence of structures on materials. Parametrization is used in such settings when properties of the models such as viscosity of fluids or electric resistivity of materials are not precisely understood and instead are treated as random variables. The resulting solutions are themselves random, and having such solutions will enable engineers to use probabilistic methods to assess the likelihood of events, for example, whether a pollutant in a liquid will exceed a limit, and to use such analyses to develop ways to ensure positive outcomes. Construction of accurate (high resolution) computational solutions is expensive, requiring significant computer time and computational resources, and there is need to reduce computational cost to make simulation useful and effective. The aim of the project was to construct algorithms to efficiently compute surrogate solutions to parameterized problems to allow for efficient and accurate simulation. The technical approach used focused on two related strategies, based on rank-reduction methods and reduced-order models. These methods construct surrogate solutions of parameter-dependent models by projection or interpolation into low-dimensional approximation spaces. Cost savings are achieved if the low-dimensional spaces can be identified and constructed efficiently and if the resulting low-dimensional algebraic systems can be solved cheaply. Accomplishments include: Theoretical and empirical demonstration of the effectiveness of fast multigrid solution strategies for computing low-rank representations of parameter-dependent solutions to discrete partial differential equations, including the first proof establishing so-called textbook convergence properties for low-rank methods. Development of efficient solution algorithms for solving nonlinear parameter-dependent partial differential equations used in models of fluid dynamics. Developent of efficient algorithms for low-rank representation of solutions of time-dependent simulations of fluid dynamics using multi-dimensional tensor representations of solutions.

97 MATHEMATICS AND COMPUTING↗

Energy Delivery Systems with Verifiable Trustworthiness (Final Report)

Energy Delivery Systems (EDS) must be verified to be free from intrusive and malicious software. One way of verifying this software is to perform device scans to detect malicious code. Because it is possible to have “fileless” malware that exists only in device (volatile) memory, offline scanning and even many forms of online scanning is insufficient for detection. This project (“Verify”) addresses this need by performing direct sampling of memory during device operation to detect unexpected or modified software while not interfering with device operation. The Verify project provides a proof-of-concept of detection by random sampling combined with remote software- and timing-based attestation methods for robust detection of in-memory threats. An external review of Verify was performed by our partner, General Electric (GE), and a summary of their findings is provided.

97 MATHEMATICS AND COMPUTING↗