Search NASA⌕ Search

SEARCH · Search NASA

Results for “root”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

ROOT I/O compression improvements for HEP analysis

We overview recent changes in the ROOT I/O system, increasing performance and enhancing it and improving its interaction with other data analysis ecosystems. Both the newly introduced compression algorithms, the much faster bulk I/O data path, and a few additional techniques have the potential to significantly to improve experiment's software performance. The need for efficient lossless data compression has grown significantly as the amount of HEP data collected, transmitted, and stored has dramatically increased during the LHC era. While compression reduces storage space and, potentially, I/O bandwidth usage, it should not be applied blindly: there are significant trade-offs between the increased CPU cost for reading and writing files and the reduce storage space.

Shadura, Oksana↗

Methods and devices for non-invasive root phenotyping

The present disclosure provides for an electronic sensor for detecting a root of a plant in soil, the electronic sensor that includes a first conductor plate configured to be disposed in soil, a switch, a power supply, and signal extractor. The switch is electrically coupled to the first conductor plate and is configured to switch between a first mode and a second mode. The power supply is electrically coupled to the switch and is configured to provide an electrical charge to the first conductor plate in the first mode of the switch. The signal extractor is electrically coupled to the switch and is configured to extract a signal response at the first conductor plate in the second mode of the switch. The present disclosure further provides a second conductor plate configured to be disposed in soil adjacent to and substantially parallel to the first conductor plate. The second conductor plate is electrically coupled to ground.

47 OTHER INSTRUMENTATION↗

Methods and devices for non-invasive root phenotyping

The present disclosure provides for an electronic sensor for detecting a root of a plant in soil, the electronic sensor that includes a first conductor plate configured to be disposed in soil, a switch, a power supply, and signal extractor. The switch is electrically coupled to the first conductor plate and is configured to switch between a first mode and a second mode. The power supply is electrically coupled to the switch and is configured to provide an electrical charge to the first conductor plate in the first mode of the switch. The signal extractor is electrically coupled to the switch and is configured to extract a signal response at the first conductor plate in the second mode of the switch. The present disclosure further provides a second conductor plate configured to be disposed in soil adjacent to and substantially parallel to the first conductor plate. The second conductor plate is electrically coupled to ground.

Benfey, Philip N.↗

Methods and devices for non-invasive root phenotyping

The present disclosure provides for an electronic sensor for detecting a root of a plant in soil, the electronic sensor that includes a first conductor plate configured to be disposed in soil, a switch, a power supply, and a signal extractor. The switch is electrically coupled to the first conductor plate and is configured to switch between a first mode and a second mode. The power supply is electrically coupled to the switch and is configured to provide an electrical charge to the first conductor plate in the first mode of the switch. The signal extractor is electrically coupled to the switch and is configured to extract a signal response at the first conductor plate in the second mode of the switch. The present disclosure further provides a second conductor plate configured to be disposed in soil adjacent to and substantially parallel to the first conductor plate. The second conductor plate is electrically coupled to ground.

Benfey, Philip↗

Root-cause analysis of the better performance of the coarse-mesh finite-difference method for CANDU-type reactors

Recent assessment results indicate that the coarse-mesh finite-difference method (FDM) gives consistently smaller percent differences in channel powers than the fine-mesh FDM when compared to the reference MCNP solution for CANDU-type reactors. However, there is an impression that the fine-mesh FDM should always give more accurate results than the coarse-mesh FDM in theory. To answer the question if the better performance of the coarse-mesh FDM for CANDU-type reactors was just a coincidence (cancellation of errors) or caused by the use of heavy water or the use of lattice-homogenized cross sections for the cluster fuel geometry in the diffusion calculation, three benchmark problems were set up with three different fuel lattices: CANDU, HWR and PWR. These benchmark problems were then used to analyze the root cause of the better performance of the coarse-mesh FDM for CANDU-type reactors. The analyses confirm that the better performance of the coarse-mesh FDM for CANDU-type reactors is mainly caused by the use of lattice-homogenized cross sections for the sub-meshes of the cluster fuel geometry in the diffusion calculation. Based on the analyses, it is recommended to use 2 x 2 coarse-mesh FDM to analyze CANDU-type reactors when lattice-homogenized cross sections are used in the core analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗