Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Petrography and Mineralogy of Basalt Fragments in Apollo 17 Double Drive Tube 73002 and 73001

The ANGSA program was formed, in part, to examine previously unstudied Apollo 17 double drive tube samples. As a part of this project, the Moon United team received eight basalt fragments from 73001 and 73002. Here we present the petrography and mineralogy of these basalt fragments. Methods: We analyzed the petrography and mineralogy of the 73001/73002 particles using Electron Probe Microanalysis (EMPA) at both Carnegie Institution for Science and the Smithsonian Institution. We made quantitative compositional maps for each sample following the methods of [1,2].

S. N. Valencia↗

Magnitude error bounds for sampled-data frequency response obtained from the truncation of an infinite series, and compensator improvement program

The frequency response method of analyzing control system performance is discussed, and the difficulty of obtaining the sampled frequency response of the continuous system is considered. An upper bound magnitude error equation is obtained which yields reasonable estimates of the actual error. Finalization of the compensator improvement program is also reported, and the program was used to design compensators for Saturn 5/S1-C dry workshop and Saturn 5/S1-C Skylab.

Mitchell, J. R.↗

GEOS-2 C-band radar system project. Spectral analysis as related to C-band radar data analysis

Work performed on spectral analysis of data from the C-band radars tracking GEOS-2 and on the development of a data compaction method for the GEOS-2 C-band radar data is described. The purposes of the spectral analysis study were to determine the optimum data recording and sampling rates for C-band radar data and to determine the optimum method of filtering and smoothing the data. The optimum data recording and sampling rate is defined as the rate which includes an optimum compromise between serial correlation and the effects of frequency folding. The goal in development of a data compaction method was to reduce to a minimum the amount of data stored, while maintaining all of the statistical information content of the non-compacted data. A digital computer program for computing estimates of the power spectral density function of sampled data was used to perform the spectral analysis study.

Source record↗

Multiple Approaches to Down Sizing of the Lunar Sample Return Collection

Future Lunar missions are planned for at least 7 days, significantly longer than the 3 days of the later Apollo missions. The last of those missions, A-17, returned 111 kg of samples plus another 20 kg of containers. The current Constellation program requirements for return weight for science is 100 kg with the hope of raising that limit to near 250 kg including containers and other non-geological materials. The estimated return weight for rock and soil samples will, at best, be about 175 kg. One method proposed to accomplish down-sizing of the collection is the use of a Geo-Lab in the lunar habitat to complete a preliminary examination of selected samples and facilitate prioritizing the return samples.

Lofgren, Gary E.↗

Some experiences with the viscous-inviscid interaction approach

Methods for simulating compressible viscous flow using the viscid-inviscid interaction approach are described. The formulations presented range from the more familiar full-potential/boundary-layer interaction schemes to a method for coupling Euler/Navier-Stokes and boundary-layer algorithms. An effort is made to describe the advantages and disadvantages of each formulation. Sample results are presented which illustrate the applicability of the methods.

Vandalsem, W. R.↗

Equilibrium shape and location of a liquid drop acoustically positioned in a resonant rectangular chamber

The effect of a standing wave field in a rectangular chamber on the shape and location of an acoustically positioned drop or bubble is calculated. The sample deformation and equilibrium position are obtained from an analysis of the spherical harmonic projections of the total surface stress tensor. The method of calculation relies on the assumed condition that the sample is only slightly distorted from a spherical form. The equilibrium location of a levitated drop is combined with a formula introduced by Hasegawa (1979) to calcualte the ka dependence of the radiation force function. The present theory is valid for large as well as small ka values. Calculations in the small ka limit agree with previous theories and experimental results. Examples are presented for nonplane-wave modes as well as plane-wave rectangular modes.

Jackson, H. W.↗

Comparison of Adsorbed Mercury Screening Method With Cold-Vapor Atomic Absorption Spectrophotometry for Determination of Mercury in Soil

A field screening method for the determination of elemental mercury in environmental soil samples involves the thermal desorption of the mercury from the sample onto gold and then the thermal desorption from the gold to a gold-film mercury vapor analyzer. This field screening method contains a large number of conditions that could be optimized for the various types of soils encountered. In this study, the conditions were optimized for the determination of mercury in silty clay materials, and the results were comparable to the cold-vapor atomic absorption spectrophotometric method of determination. This paper discusses the benefits and disadvantages of employing the field screening method and provides the sequence of conditions that must be optimized to employ this method of determination on other soil types.

Easterling, Donald F.↗

Informatics and High Throughput Screening of Thermophysical Properties

The combination of computer-aided experiments with computational modeling enables a new class of powerful tools for materials research. A non-contact method for measuring density, thermal expansion, and creep of undercooled and high-temperature materials has been developed, using electrostatic levitation and optical diagnostics, including digital video. These experiments were designed to take advantage of the large volume of data (many gigabytes/experiment, terabytes/campaign) to gain additional information about the samples. For example, using sub-pixel interpolation to measure about 1000 vectors per image of the sample's surface allows the density of an axisymmetric sample to be determined to an accuracy of about 200 ppm (0.02%). A similar analysis applied to the surface shape of a rapidly rotating sample is combined with finite element modeling to determine the stress-dependence of creep in the sample in a single test. Details of the methods for both the computer-aided experiments and computational models will be discussed.

Hyers, Robert W.↗

Kalman Filtering and RTS Smoothing for Arc-Jet Sample Edge Tracking

Accurate and temporally consistent measurements of test-article recession are required to characterize material response during arc-jet ablation experiments. However, image-based boundary measurements are often affected by segmentation noise, brightness variations, and frame-to-frame variability. This work extends arcjetCV [1] with filtering methods for tracking the evolving boundaries of hemispherical and ISO-Q test articles. Two boundary-tracking approaches based on Kalman filtering [2] were implemented. The first applies a point-wise Kalman filter followed by a Rauch–Tung–Striebel smoother [3] to individual boundary-point locations. The second applies the same filtering and smoothing framework to a reduced set of geometry-dependent shape parameters. The point-wise method reduces local frame-to-frame fluctuations while preserving spatial details along the detected boundary. The shape-parameter method provides a compact and geometrically constrained estimate of the sample contour. Figure 1 illustrates the two approaches for a hemispherical test article. Both methods improve temporal consistency and support more robust estimation of surface recession from arc-jet imagery. The two filtering approaches provide complementary representations of boundary evolution and improve the reliability of image-based recession measurements during arc-jet experiments.

recession measurement↗

Launch Complex 39B, SWMU 009, 2023 Performance Monitoring and Air Sparge Expansion Construction Completion Report, Kennedy Space Center, Florida

The 2023 Performance Monitoring and Construction Completion Report (PM-CCR) presents the findings, observations, and results for Air Sparging (AS) operations and expansion activities, as well as sitewide groundwater monitoring for Launch Complex 39B (LC39B), Solid Waste Management Unit (SWMU) 009, at Kennedy Space Center (KSC), Florida. The reporting period for activities covered under this PM-CCR is from January 1, 2023, to December 31, 2023. At LC39B, AS operations began in 2017 in the area west of the launch pad, in the liquid oxygen (LOX) tank area located northwest of the launch pad, and in an area outside of the perimeter fence to protect nearby Outstanding Florida Waters (OFW). The LC39B AS system was installed with 279 AS wells to depths ranging from 23 to 60 feet below land surface (bls), including the sump, correlating to top of screen depths ranging from 20 to 57 feet bls. In December 2022, a total of 22 AS wells were abandoned to support launch pad crane operations, and in November 2023, the system was expanded with five additional AS wells installed to 13 or 17 feet bls near the LOX tank. The remedial objective of the LC39B AS Interim Measure (IM) is to actively decrease concentrations of contaminants of concern (COCs) in groundwater, specifically trichloroethene (TCE), cis-1,2-Dichloroethene (cDCE), and vinyl chloride (VC), to less than their respective Natural Attenuation Default Concentrations (NADCs), so LC39B can transition into a Long-Term Monitoring (LTM) program. This PM-CCR presents the following information for LC39B: • AS system operations and maintenance (O&M) (Year 7 of operation) from January 2023 to December 2023, to include AS trailer relocation in March 2023 and subsequent replacement and re-start in June 2023. • Construction completion details for AS system expansion, which included installation of five new AS wells and one new monitoring well in November 2023. As part of expansion activities, soil samples were also collected for petroleum analysis; no exceedances were identified, and no further investigation for petroleum is warranted. • Performance monitoring results for groundwater sampling events conducted in May/June 2023 (30 wells) and November 2023 (31 wells) in the AS IM area and in the Low Concentration Plume (LCP) areas located north and east of the launch pad for volatile organic compound (VOC) analysis. • Sampling results for one monitoring well, LOX-IW0012S, which is sampled for aluminum on an annual basis (May/June 2023). This well was resampled in November 2023 for both total and dissolved aluminum. Due to a communication error with the laboratory, the May/June 2023 sample was analyzed for total aluminum only. • Groundwater sampling results for per- and polyfluoroalkyl substances (PFAS) collected from seven monitoring wells during the May/June 2023 event to further investigate the Former Sewage Treatment Plant #6 and Percolation Pond area, west of the launch pad. O&M and performance monitoring results show that the AS system at LC39B is operating as designed and meeting performance criteria. Overall runtime was 45 percent (%) during the reporting period (January to December), but the operational runtime was 78% during the timeframe when the system could run (June to December). The most significant downtime contributor was post-launch crane operations following the Artemis launch on November 16, 2022, which lasted until June 2023. During that timeframe, the AS trailer at LC39B was relocated to another KSC remediation site (Wilson Corners) and was subsequently replaced with the AS trailer from the Paint & Oil Locker (POL) remediation site at KSC to resume AS system operations. Performance monitoring results in the AS IM and LCP areas continue to show reduction in COC concentrations over time when compared to baseline levels. In 2023, only one monitoring well (MW0048) detected a COC exceeding its NADC (VC at 740 micrograms per liter [µg/L]), which marks the baseline result for this new well installed during system expansion. Across the rest of the site, VC concentrations have declined or remained stable during the 2023 sampling events. Excluding MW0048, the highest VC result in 2023 was during the May/June sampling event with a concentration of 63 µg/L at MW0032, which is located near MW0048 and the AS expansion area by the LOX tank. TCE was detected in select monitoring wells in the IM area in 2023, but only two locations exceeded the State of Florida Groundwater Cleanup Target Level (GCTL): MW0032 (21 µg/L in May/June 2023 and 9.1 µg/L in November 2023) and MW0036 (5.0 µg/L in November 2023). MW0036 is also located near the LOX tank, on the north side, where the AS system is still operational (Zone Z4). cDCE and trans-1,2-dichloroethene concentrations were less than laboratory method detection limits or their respective GCTLs in all wells sampled in 2023. Near the OFW located northwest of the launch complex, all COC concentrations were less than laboratory method detection limits from monitoring wells (MW0039, MW0040, and LOXTA0002S) sampled in 2023. Aluminum results from LOX-IW0012S, which has been sampled routinely since 2006, detected a total aluminum concentration of 3,900 µg/L during the May/June 2023 sampling event. Results from the November 2023 event detected 5,700 µg/L for total aluminum and 5,500 µg/L for dissolved aluminum. These concentrations slightly decreased from the previous year but remain relatively consistent with historical detections. Aluminum will continue to be sampled on an annual basis at this well as results still exceed the GCTL of 200 µg/L and the Upper Limit of the KSC Background Concentration of 280 µg/L. PFAS results detected nine different PFAS compounds (out of 32 analyzed) from seven wells sampled. Two PFAS compounds, perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), currently have FDEP Provisional GCTLs of 70 nanograms per liter (ng/L). All seven samples collected resulted in concentrations less than the FDEP Provisional GCTLs for both PFAS compounds; no exceedances were observed. PFOS and PFOA also have assigned United States Environmental Protection Agency (USEPA) Maximum Contaminant Levels (MCLs) of 4 nanograms per liter (ng/L). None of the PFOS results exceeded the USEPA MCLs. PFOA was detected in two samples above the USEPA MCL at concentrations of 5.8 ng/L (ECS-IW0009I) and 5.5 ng/L (ECS-IW0009S). Three other PFAS compounds, perfluorohexanesulfonic acid (PFHxS), perfluoro-n-nonanoic acid (PFNA), and hexafluoropropylene oxide dimer acid (GenX), currently have USEPA MCLs of 10 ng/L. PFHxS, PFNA, and GenX were not detected at concentrations greater than their respective USEPA MCLs in any of the seven wells. PFAS compounds without FDEP Provisional GCTLs or USEPA MCLs were screened against USEPA RSLs. No other detections exceeded their respective USEPA RSLs. Additional PFAS sampling will be conducted as part of a future PFAS Site Assessment. Based on O&M activities and performance monitoring, the following is recommended for LC39B: • Continue with Year 8 AS system operation within Zone Z4, which includes the AS expansion area. Zone Z3, which has been off since 2018, should remain off as no rebound has been observed. Zones Z1 and Z2, which were turned off at the end of 2022, will remain shut down as monitoring well results have consistently been below GCTLs or have low-level detections with stable or decreasing trends (Meeting Minute 2402-M10, Decision 2402-D30). • Continue with performance monitoring in 2024 with the same monitoring well network as 2023, except with the addition of MW0048 in both semi-annual events. Baseline concentrations for this well were collected during the November 2023 performance monitoring event. Semi-annual sampling should be planned for the May 2024 and November 2024 timeframes (Meeting Minute 2402-M10, Decision 2402-D31). • Continue sampling monitoring well, LOX-IW0012S, for aluminum (total and dissolved) on an annual basis in May 2024. It is also recommended to re-develop this well prior to the next sampling event (Meeting Minute 2402-M10, Decision 2402-D32). The above recommendations for LC39B were presented at the February 2024 KSCRT Meeting, with Team consensus reached on the path forward. The contents of this PM-CCR were also presented at this meeting.

Deborah M Wilson↗

Mechanical Impact Testing: A Statistical Measurement

In the decades since the 1950s, when NASA first developed mechanical impact testing of materials, researchers have continued efforts to gain a better understanding of the chemical, mechanical, and thermodynamic nature of the phenomenon. The impact mechanism is a real combustion ignition mechanism that needs understanding in the design of an oxygen system. The use of test data from this test method has been questioned due to lack of a clear method of application of the data and variability found between tests, material batches, and facilities. This effort explores a large database that has accumulated over a number of years and explores its overall nature. Moreover, testing was performed to determine the statistical nature of the test procedure to help establish sample size guidelines for material characterization. The current method of determining a pass/fail criterion based on either light emission or sound report or material charring is questioned.

Engel, Carl D.↗

Single-Transducer, Ultrasonic Imaging Method for High-Temperature Structural Materials Eliminates the Effect of Thickness Variation in the Image

NASA Lewis Research Center's Life Prediction Branch, in partnership with Sonix, Inc., and Cleveland State University, recently advanced the development of, refined, and commercialized an advanced nondestructive evaluation (NDE) inspection method entitled the Single Transducer Thickness-Independent Ultrasonic Imaging Method. Selected by R&D Magazine as one of the 100 most technologically significant new products of 1996, the method uses a single transducer to eliminate the superimposing effects of thickness variation in the ultrasonic images of materials. As a result, any variation seen in the image is due solely to microstructural variation. This nondestructive method precisely and accurately characterizes material gradients (pore fraction, density, or chemical) that affect the uniformity of a material's physical performance (mechanical, thermal, or electrical). Advantages of the method over conventional ultrasonic imaging include (1) elimination of machining costs (for precision thickness control) during the quality control stages of material processing and development and (2) elimination of labor costs and subjectivity involved in further image processing and image interpretation. At NASA Lewis, the method has been used primarily for accurate inspections of high temperature structural materials including monolithic ceramics, metal matrix composites, and polymer matrix composites. Data were published this year for platelike samples, and current research is focusing on applying the method to tubular components. The initial publicity regarding the development of the method generated 150 requests for further information from a wide variety of institutions and individuals including the Federal Bureau of Investigation (FBI), Lockheed Martin Corporation, Rockwell International, Hewlett Packard Company, and Procter & Gamble Company. In addition, NASA has been solicited by the 3M Company and Allison Abrasives to use this method to inspect composite materials that are manufactured by these companies.

Roth, Don J.↗

Chance-Constrained System Identification of Nonlinear Discrete Systems with Safety and Stability Guarantees

This paper presents a discrete-time nonlinear system identification method while satisfying the stability and safety properties of the system with high probability. An Extreme Learning Machine (ELM) is used with a Gaussian assumption on the function reconstruction error. A quadratically constrained quadratic program (QCQP) is developed with probabilistic safety and stability constraints that are only required to be satisfied at sampled points inside the invariant region. The proposed method is validated using two simulation examples: a two degrees-of-freedom (DoF) robot manipulator with constraints on joint angles whose trajectories are guaranteed to remain inside a safe set and on motion trajectories data of a hand-drawn shape.

Iman Salehi↗

Non-nulling seven-hole probes for high angle flow measurement

This paper illustrates a method for calibrating seven-hole probes to measure local total and static pressures and relative flow angles of up to 70 degrees in subsonic compressible flows. The method of Latin Squares was used to statistically sample a large and otherwise unmanageable data set, thereby reducing to a minimum the number of data points required to construct a polynomial curve fit to the data. Calibration produces three-variable third order polynomials which permit all of the desired flow properties to be found explicitly from probe measured pressures. This method determines the flow angles to within 2 degrees and Mach number to within 0.04 with 95 percent certainty.

Gerner, A. A.↗

Instrumentation for Measurement of Gas Permeability of Polymeric Membranes

A mass spectrometric 'Dynamic Delta' method for the measurement of gas permeability of polymeric membranes has been developed. The method is universally applicable for measurement of the permeability of any gas through polymeric membrane materials. The usual large sample size of more than 100 square centimeters required for other methods is not necessary for this new method which requires a size less than one square centimeter. The new method should fulfill requirements and find applicability for industrial materials such as food packaging, contact lenses and other commercial materials where gas permeability or permselectivity properties are important.

Upchurch, Billy T.↗

Elliptic Volume Grid Generation for Viscous CFD Parametric Design Studies

This paper presents a robust method for the generation of zonal volume grids of design parametrics for aerodynamic configurations. The process utilizes simple algebraic techniques with parametric splines coupled with elliptic volume grid generation to generate isolated zonal grids for changes in body configuration needed to perform parametric design studies. Speed of the algorithm is maximized through the algebraic methods and reduced number of grid points to be regenerated for each design parametric without sacrificing grid quality and continuity within the volume domain. The method is directly applicable to grid reusability, because it modifies existing ow adapted volume grids and enables the user to restart the CFD solution process with an established flow field. Use of this zonal approach reduces computer usage time to create new volume grids for design parametric studies by an order of magnitude, as compared to current methods which require the regeneration of an entire volume grid. A sample configuration of a proposed Single Stage-to-Orbit Vehicle is used to illustrate an application of this method.

Alter, Stephen J.↗

Determination of 2,3,7,8-chlorine-substituted dibenzo-p-dioxins and -furans at the part per trillion level in United States beef fat using high-resolution gas chromatography/high-resolution mass spectrometry

As part of the U.S. EPA Dioxin Reassessment Program, the 2,3,7,8-chlorine-substituted dibenzo-p-dioxins and furans were measured at part per trillion (ppt) levels in beef fat collected from slaughter facilities in the United States. This is the first statistically designed national survey of these compounds in the U.S. beef supply. Analyte concentrations were determined by high-resolution gas chromatography/high-resolution mass spectrometry, using isotope dilution methodology. Method limits of detection on a whole weight basis were 0.05 ppt for TCDD and 0.10 ppt for TCDF, 0.50 ppt for the pentas (PeCDDs/PeCDFs)/hexas (HxCDDs/HxCDFs)/heptas (HpCDDs/HpCDFs), and 3.00 ppt for the octas (OCDD/OCDF). Method detection and quantitation limits were established on the basis of demonstrated performance criteria utilizing fortified samples rather than by conventional signal-to-noise or variability of response methods. The background subtraction procedures developed for this study minimized the likelihood of false positives and increased the confidence associated with reported values near the detection limits. Mean and median values for each of the 2,3,7,8-Cl-substituted dioxins and furans are reported, along with the supporting information required for their interpretation. The mean toxic equivalence values for the samples are 0.35 ppt (nondetects = 0) and 0.89 ppt (nondetects = 1/2 LOD).

Benzofurans/analysis↗

Evaluation of the ERBE scene identification algo-rithm

The sensitivity of the radiation budget parameters and the scene selection process to different factors is evaluated. The use of ERB-7 CLE models provides instantaneous albedo and longwave flux values which are in essential agreement in the 70 deg cutoff case with those from the SAB method. The increase in albedo with increasing satellite zenith angle cutoff is not apparent at the target area level for different surface types. GOES models seem to show an increase in instantaneous albedo at the global level with satellite zenith angle of the same nature as the ERB-7 models investigated in a previous report and are, therefore, probably not an improvement. The use of recently derived NCLE models did not make a noticeable change in the budget parameters; but the cloud classification did show hemispherical differences and caused a day-night readjustment of cloudiness amounts. Preliminary results for an additional month (December 1979) indicate good agreement between the SAB and MLE methods. Additional work is required to establish the agreement for all seasons. Comparison of derived cloud amounts with other data sets such as THIR/TOMS indicates good zonal agreement. Sampling adequacy investigations at different temporal averaging intervals with the SAB method, indicate large uncertainties in small time average cases. For a 6-day averaging period, sampling is very poor with only 23% of the globe contributing toward the global mean albedo. Effect of modifications to the MLE procedure seem to have little effect on the derived budget quantities in an averaged sense. Significant differences in the flux values due to differences in scene selection are apparent in individual target areas studies. A modification of the MLE procedure to mimic the perpendicular bisector algorithm indicated no effect on the gross radiation budget quantities.

Vemury, S. K.↗