Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Serum Proteome Profiles in Stricturing Crohn’s Disease: A pilot study.

Background: Crohn’s disease (CD) is a form of inflammatory bowel disease (IBD) with different described behaviors, including stricture. At present, there are no laboratory studies that can differentiate stricturing CD from other phenotypes of IBD. We performed a pilot study to examine differences in the proteome among patients with stricturing Crohn’s disease, non-stricturing Crohn’s disease, and ulcerative colitis (UC). Methods: Serum samples were selected from the Ocean State Crohn’s and Colitis Area Registry (OSCCAR), an established cohort of patients with IBD. Crohn’s disease patients with surgically-resected stricture were matched with similar patients with Crohn’s disease without known stricture, and with UC. Serum samples from each patient were digested and analyzed using liquid chromatography-mass spectrometry to characterize the proteome. Statistical analyses were performed to identify peptides and proteins that can differentiate CD with stricture. Results: Samples from 9 patients in each group (27 total patients) were analyzed. Baseline demographic characteristics were similar among the three groups. We quantified 7668 peptides and 897 proteins for analysis. ROC analysis identified a subset of peptides with an area under the curve greater than 0.9, indicating greater separation potential. Partial least squares discriminant analysis was able to distinguish among the three groups with up to 70% accuracy by peptides, and up to 80% accuracy by proteins. We identified the significantly different proteins and peptides, and determined their function based on previously published literature. Conclusions: The serum of patients with stricturing CD, non-stricturing CD, and UC are distinguishable via proteomic analysis. Some of the proteins that differentiate the stricturing phenotype have been implicated in complement activation, fibrinolytic pathways, and lymphocyte adhesion.

Environmental Molecular Sciences Laboratory↗

Discrete generative diffusion models without stochastic differential equations: A tensor network approach

Diffusion models (DMs) are a class of generative machine learning methods that sample a target distribution by transforming samples of a trivial (often Gaussian) distribution using a learned stochastic differential equation. In standard DMs, this is done by learning a “score function” that reverses the effect of adding diffusive noise to the distribution of interest. Here we consider the generalisation of DMs to lattice systems with discrete degrees of freedom, and where noise is added via Markov chain jump dynamics. We show how to use tensor networks (TNs) to efficiently define and sample such “discrete diffusion models” (DDMs) without explicitly having to solve a stochastic differential equation. We show the following: (i) by parametrising the data and evolution operators as TNs, the denoising dynamics can be represented exactly; (ii) the auto-regressive nature of TNs allows to generate samples efficiently and without bias; (iii) for sampling Boltzmann-like distributions, TNs allow to construct an efficient learning scheme that integrates well with Monte Carlo. We illustrate this approach to study the equilibrium of two models with non-trivial thermodynamics, the d = 1 constrained Fredkin chain and the d = 2 Ising model. Published by the American Physical Society 2025

Causer, Luke (ORCID:0000000194243473)↗

Formation of an r8-Dominant Si Material

The rhombohedral phase of Si (r8-Si), a promising semiconducting material, is formed by indentation together with the body-centered cubic phase (bc8-Si). Using a novel sample preparation method, x-ray diffraction is used to determine the relative volume of these phases in indented Si and allow observation of a distorted unit cell along the direction of indentation loading. Theoretical calculations together with these observations suggest the indent contains an intrinsic compression of ~4 GPa that stabilizes the r8 phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A capillary-based microfluidic device enables primary high-throughput room-temperature crystallographic screening

A novel capillary-based microfluidic strategy to accelerate the process of small-molecule-compound screening by room-temperature X-ray crystallography using protein crystals is reported. The ultra-thin microfluidic devices are composed of a UV-curable polymer, patterned by cleanroom photolithography, and have nine capillary channels per chip. The chip was designed for ease of sample manipulation, sample stability and minimal X-ray background. 3D-printed frames and cassettes conforming to SBS standards are used to house the capillary chips, providing additional mechanical stability and compatibility with automated liquid- and sample-handling robotics. These devices enable an innovative in situ crystal-soaking screening workflow, akin to high-throughput compound screening, such that quantitative electron density maps sufficient to determine weak binding events are efficiently obtained. This work paves the way for adopting a room-temperature microfluidics-based sample delivery method at synchrotron sources to facilitate high-throughput protein-crystallography-based screening of compounds at high concentration with the aim of discovering novel binding events in an automated manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Iterative Bragg peak removal on X-ray absorption spectra with automatic intensity correction

This study introduces a novel iterative Bragg peak removal with automatic intensity correction (IBR-AIC) methodology for X-ray absorption spectroscopy (XAS), specifically addressing the challenge of Bragg peak interference in the analysis of crystalline materials. The approach integrates experimental adjustments and sophisticated post-processing, including an iterative algorithm for robust calculation of the scaling factor of the absorption coefficients and efficient elimination of the Bragg peaks, a common obstacle in accurately interpreting XAS data, particularly in crystalline samples. The method was thoroughly evaluated on dilute catalysts and thin films, with fluorescence mode and large-angle rotation. The results underscore the technique's effectiveness, adaptability and substantial potential in improving the precision of XAS data analysis. While demonstrating significant promise, the method does have limitations related to signal-to-noise ratio sensitivity and the necessity for meticulous angle selection during experimentation. Overall, IBR-AIC represents a significant advancement in XAS, offering a pragmatic solution to Bragg peak contamination challenges, thereby expanding the applications of XAS in understanding complex materials under diverse experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crystal structure solution and high-temperature thermal expansion in NaZr 2 (PO 4 ) 3 -type materials

The NaZr 2 P 3 O 12 family of materials have shown low and tailorable thermal expansion properties. In this study, SrZr 4 P 6 O 24 (SrO·4ZrO 2 ·3P 2 O 5 ), CaZr 4 P 6 O 24 (CaO·4ZrO 2 ·3P 2 O 5 ), MgZr 4 P 6 O 24 (MgO·4ZrO 2 ·3P 2 O 5 ), NaTi 2 P 3 O 12 [½(Na 2 O·4TiO 2 ·3P 2 O 5 )], NaZr 2 P 3 O 12 [½(Na 2 O·4ZrO 2 ·3P 2 O 5 )], and related solid solutions were synthesized using the organic–inorganic steric entrapment method. The samples were characterized by in-situ high-temperature X-ray diffraction from 25 to 1500°C at the Advanced Photon Source and National Synchrotron Light Source II. The average linear thermal expansion of SrZr 4 P 6 O 24 and CaZr 4 P 6 O 24 was between −1 × 10 −6 per °C and 6 × 10 −6 per °C from 25 to 1500°C. The crystal structures of the high-temperature polymorphs of CaZr 4 P 6 O 24 and SrZr 4 P 6 O 24 with R 3 c symmetry were solved by Fourier difference mapping and Rietveld refinement. This polymorph is present above ∼1250°C. This work measured thermal expansion coefficients to 1500°C for all samples and investigated the differences in thermal expansion mechanisms between polymorphs and between compositions.

36 MATERIALS SCIENCE↗

Bi-fidelity Gradient-Based Approach for Nonlinear Well Logging Inverse Problems

Solving a non-linear inverse problem is challenging in computational science and engineering. Sampling based methods require a large number of model valuations; gradientbased methods require fewer model evaluations but only find the local minima. Multifidelity optimization combines the low fidelity model and the high-fidelity model to achieve both high accuracy and high efficiency. In this paper, we present a bi-fidelity approach to solve non-linear inverse problems. In the bi-fidelity inversion method, the low-fidelity model is used to acquire a good initial guess, and the high-fidelity model is used to locate the global minimum. Combined with a multi-start optimization scheme, the proposed approach significantly increases the possibility of finding the global minimum for nonlinear inverse problems with many local minima. The method is tested with two toy problems and then applied to an electromagnetic well logging inverse problem, which is difficult to solve using traditional gradient-based methods. The bi-fidelity method provides promising inversion results and can be easily applied to traditional gradient-based methods.

42 ENGINEERING↗

Estimating Lossy Compressibility of Scientific Data Using Deep Neural Networks

Simulation based scientific applications generate increasingly large amounts of data on high-performance computing (HPC) systems. To allow data to be stored and analyzed efficiently, data compression is often utilized to reduce the volume and velocity of data. However, a question often raised by domain scientists is the level of compression that can be expected so that they can make more informed decisions, balancing between accuracy and performance. In this letter, we propose a deep neural network based approach for estimating the compressibility of scientific data. To train the neural network, we build both general features as well as compressor-specific features so that the characteristics of both data and lossy compressors are captured in training. Our approach is demonstrated to outperform a prior analytical model as well as a sampling based approach in the case of a biased estimation, i.e., for SZ. However, for the unbiased estimation (i.e., ZFP), the sampling based approach yields the best accuracy, despite the high overhead involved in sampling the target dataset.

97 MATHEMATICS AND COMPUTING↗

Establishing reference ranges for circulating biomarkers of drug‐induced liver injury in healthy human volunteers 1

Aims The potential of mechanistic biomarkers to improve prediction of drug‐induced liver injury (DILI) and hepatic regeneration is widely acknowledged. We sought to determine reference intervals for new biomarkers of DILI and regeneration, as well as to characterize their natural variability and impact of diurnal variation. Methods Serum samples from 227 healthy volunteers were recruited as part of a cross‐sectional study; of these, 25 subjects had weekly serial sampling over 3 weeks, while 23 had intensive blood sampling over a 24h period. Alanine aminotransferase (ALT), MicroRNA‐122 (miR‐122), High Mobility Group Box‐1 (HMGB1), total Keratin‐18 (K18), caspase‐cleaved Keratin‐18 (ccK18), Glutamate Dehydrogenase (GLDH) and Macrophage Colony‐Stimulating Factor‐1 (CSF‐1) were assayed. Results Reference intervals were established for each biomarker based on the 97.5% quantile (90% CI) following the assessment of fixed effects in univariate and multivariable models. Intra‐individual variability was found to be non‐significant, and there was no significant impact of diurnal variation. Conclusion Reference intervals for novel DILI biomarkers have been described. An upper limit of a reference range might represent the most appropriate mechanism to utilize these data. These data can now be used to interpret data from exploratory clinical DILI studies and to assist their further qualification as required by regulatory authorities.

Jorgensen, Andrea L. [Department of Health Data Sc↗

The ionic conductivity of Sm‐doped ceria

Abstract The oxygen ion conductivity of polycrystalline samples of Sm‐doped ceria and of Gd‐doped ceria is studied as a function of doping fraction and temperature using impedance spectroscopy allowing the separation of bulk and grain boundary conductivity. The introduction of a fine spacing for the Sm dopant fraction allows the clear identification of the dopant fraction leading to the largest bulk conductivity. At 267°C, the largest bulk conductivity is shown for Ce 0.93 Sm 0.07 O 1.965 . With increasing temperature, indications of an increase in the dopant fraction, which leads to the maximum in conductivity, are found. For the grain boundary conductivity, the maximum appears at larger dopant fractions compared to the bulk conductivity. The largest total conductivity for both dopants is again found for Sm‐doped ceria. In literature, different syntheses and sample preparation methods led to larger total conductivities for Gd‐doped ceria. In this work, we demonstrate that the variation of sintering conditions leads to scattering in the conductivity over one order of magnitude. Finally, we demonstrate that, in nominally pure cerium oxide, impurities dominate the ionic conductivity.

Koettgen, Julius↗

Evolutionary and demographic correlates of Pleistocene coastline changes in the Sicilian wall lizard Podarcis wagleriana

Abstract Aim Emergence of coastal lowlands during Pleistocene ice ages might have provided conditions for glacial expansions (demographic and spatial), rather than contraction, of coastal populations of temperate species. Here, we tested these predictions in the insular endemic Sicilian wall lizard Podarcis wagleriana . Location Sicily and neighbouring islands. Methods We sampled 179 individuals from 45 localities across the whole range of P. wagleriana . We investigated demographic and spatial variations through time using Bayesian coalescent models (Bayesian phylogeographic reconstruction, Extended Bayesian Skyline plots, Isolation‐with‐migration models) based on multilocus DNA sequence data. We used species distribution modelling to reconstruct present and past habitat suitability. Results We found two main lineages distributed in the east and west portions of the current species range and a third lineage restricted to a small area in the north of Sicily. Multiple lines of evidence from palaeogeographic (shorelines), palaeoclimatic (species distribution models), and multilocus genetic data (demographic and spatial Bayesian reconstructions) indicate that these lineages originated in distinct refugia, located in the north‐western and south‐eastern coastal lowlands, during Middle Pleistocene interglacial phases, and came into secondary contact following demographic and spatial expansions during the last glacial phase. Main conclusions This scenario of interglacial contraction and glacial expansion is in sharp contrast with patterns commonly observed in temperate species on the continent but parallels recent findings on other Mediterranean island endemics. Such a reverse expansion–contraction ( EC ) dynamic has been likely associated with glacial increases of climatically suitable coastal lowlands, suggesting this might be a general pattern in Mediterranean island species and also in other coastal regions strongly affected by glacial marine regressions during glacial episodes. This study provides explicit predictions and some methodological recommendations for testing the reverse EC model in other region and taxa.

Senczuk, Gabriele↗

Instrumentation to Monitor Transient Developing Periodic Flow in Newtonian Slurries

This paper describes measurement techniques developed and applied to characterize solids mobilization and mixing of Newtonian slurries that are subjected to transient, periodic, developing flows. Metrics to characterize mobilization and mixing are the just suspended velocity (UJS) and the cloud height (HC). Two ultrasonic instruments to characterize pulse jet mixing of slurries were developed and deployed to measure related metrics: the thickness of the settled bed (used to determine mobilization) and the concentration within the cloud as a function of elevation [C(Z)]. A second method, continuous sample extraction, characterization, and reinsertion was successfully used to measure average density and characterize the concentration within the cloud. Testing focused on mixing vessels using intermitent jet mixers oriented vertically downward. Descriptions of the instruments and instrument performance are presented. These techniques were an effective approach to characterize mixing phenomena, determine mixing energy required to fully mobilize vessel contents, and to determine mixing times for process evaluation.

concentration profile↗

Gamma Knife output factor measurements using VIP polymer gel dosimetry

Purpose: Water equivalent polymer gel dosimeters and magnetic resonance imaging were employed to measure the output factors of the two smallest treatment fields available in a Gamma Knife model C radiosurgery unit, those formed employing the 4 and 8 mm final collimator helmets. Methods: Three samples of the VIP normoxic gel formulation were prepared and irradiated so that a single shot of the field whose output factor is to be measured and a single shot of the reference 18 mm field were delivered in each one. Emphasis is given to the development and benchmarking of a refined data processing methodology of reduced uncertainty that fully exploits the 3D dose distributions registered in the dosimeters. Results: Polymer gel results for the output factor of the 8 mm collimator helmet are found to be in close agreement with the corresponding value recommended by the vendor (0.955{+-}0.007 versus 0.956, respectively). For the 4 mm collimator helmet, however, polymer gel results suggest an output factor 3% lower than the value recommended by the vendor (0.841{+-}0.009 versus 0.870, respectively). Conclusions: A comparison with corresponding measurements published in the literature indicates that output factor results of this work are in agreement with those obtained using dosimetric systems which, besides fine spatial resolution and lack of angular and dose rate dependence of the dosimeter's response, share with polymer gels the favorable characteristic of minimal radiation field perturbation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Temperature and temporal dependence of the optical response for a radiochromic dosimeter

Purpose: Both temporal and thermal dependencies of the dose response have been observed in radiochromic dosimeters. As these dependencies may be influenced by the dose level, the present study investigates the temperature dependence during irradiation and the temporal change of the optical response following irradiation of radiochromic dosimeters at a range of doses. Methods: Cuvette samples of the PRESAGE Trade-Mark-Sign radiochromic dosimeter were irradiated within a dose range of 0-10 Gy at irradiation temperatures within 5-35 Degree-Sign C and postirradiation storage within 6-30 Degree-Sign C. The optical response due to irradiation was measured using a standard spectrophotometer and the data were analyzed in terms of thermal and temporal change. Results: The initial dose response was linear over the applied dose range independent of irradiation temperature. However, the optical response to a specific dose increased exponentially with irradiation temperature corresponding to an activation energy of 0.114 {+-} 0.007 eV. The temporal change in dose response after irradiation consisted of an offset, an auto-oxidation rate with activation energy 0.84 {+-} 0.03 eV, and an initial exponential increase in optical response (1.6 {+-} 0.2 eV) followed by an exponential decrease in optical response (0.98 {+-} 0.08 eV). These contributions depended on both storage temperature and the dose given, leading to a nonlinear dose response with time at low storage temperatures and a high auto-oxidation rate at high storage temperatures. Conclusions: Thermal equilibration is important to the radiochromic dosimeter investigated due to an exponential change in dose response with irradiation temperature and a considerable postirradiation temporal change in response. For the dosimeter version investigated in this study, a compromise in storage temperature has to be made between increasing the nonlinearity of the dose response with time and inducing a high auto-oxidation rate.

36 MATERIALS SCIENCE↗

Ion chamber absorbed dose calibration coefficients, N{sub D,w}, measured at ADCLs: Distribution analysis and stability

Purpose: To analyze absorbed dose calibration coefficients, N{sub D,w}, measured at accredited dosimetry calibration laboratories (ADCLs) for client ionization chambers to study (i) variability among N{sub D,w} coefficients for chambers of the same type calibrated at each ADCL to investigate ion chamber volume fluctuations and chamber manufacturing tolerances; (ii) equivalency of ion chamber calibration coefficients measured at different ADCLs by intercomparing N{sub D,w} coefficients for chambers of the same type; and (iii) the long-term stability of N{sub D,w} coefficients for different chamber types by investigating repeated chamber calibrations. Methods: Large samples of N{sub D,w} coefficients for several chamber types measured over the time period between 1998 and 2014 were obtained from the three ADCLs operating in the United States. These are analyzed using various graphical and numerical statistical tests for the four chamber types with the largest samples of calibration coefficients to investigate (i) and (ii) above. Ratios of calibration coefficients for the same chamber, typically obtained two years apart, are calculated to investigate (iii) above and chambers with standard deviations of old/new ratios less than 0.3% meet stability requirements for accurate reference dosimetry recommended in dosimetry protocols. Results: It is found that N{sub D,w} coefficients for a given chamber type compared among different ADCLs may arise from differing probability distributions potentially due to slight differences in calibration procedures and/or the transfer of the primary standard. However, average N{sub D,w} coefficients from different ADCLs for given chamber types are very close with percent differences generally less than 0.2% for Farmer-type chambers and are well within reported uncertainties. Conclusions: The close agreement among calibrations performed at different ADCLs reaffirms the Calibration Laboratory Accreditation Subcommittee process of ensuring ADCL conformance with National Institute of Standards and Technology standards. This study shows that N{sub D,w} coefficients measured at different ADCLs are statistically equivalent, especially considering reasonable uncertainties. This analysis of N{sub D,w} coefficients also allows identification of chamber types that can be considered stable enough for accurate reference dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Preclinical investigation for developing injectable fiducial markers using a mixture of BaSO{sub 4} and biodegradable polymer for proton therapy

Purpose: The aim of this study is to investigate the use of mixture of BaSO{sub 4} and biodegradable polymer as an injectable nonmetallic fiducial marker to reduce artifacts in x-ray images, decrease the absorbed dose distortion in proton therapy, and replace permanent metal markers. Methods: Two samples were made with 90 wt. % polymer phosphate buffer saline (PBS) and 10 wt. % BaSO{sub 4} (B1) or 20 wt. % BaSO{sub 4} (B2). Two animal models (mice and rats) were used. To test the injectability and in vivo gelation, a volume of 200 μl at a pH 5.8 were injected into the Sprague-Dawley rats. After sacrificing the rats over time, the authors checked the gel morphology. Detectability of the markers in the x-ray images was tested for two sizes (diameters of 1 and 2 mm) for B1 and B2. Four samples were injected into BALB/C mice. The polymer mixed with BaSO{sub 4} transform from SOL at 20 °C with a pH of 6.0 to GEL in the living body at 37 °C with a pH of 7.4, so the size of the fiducial marker could be controlled by adjusting the injected volume. The detectability of the BaSO{sub 4} marker was measured in x-ray images of cone beam CT (CBCT), on-board imager [anterior–posterior (AP), lateral], and fluoroscopy (AP, lateral) using a Novalis-TX (Varian Medical Systems, Palo Alto, CA) repeatedly over 4 months. The volume, HU, and artifacts for the markers were measured in the CBCT images. Artifacts were compared to those of gold marker by analyzing the HU distribution. The dose distortion in proton therapy was computed by using a Monte Carlo (MC) code. A cylindrical shaped marker (diameter: 1 or 2 mm, length: 3 mm) made of gold, stainless-steel [304], titanium, and 20 wt. % BaSO{sub 4} was positioned at the center of the spread-out Bragg peak (SOBP) in parallel or perpendicular to the beam entrance. The dose distortion was measured on the depth dose profile across the markers. Results: Transformation to GEL and the biodegradation were verified. All BaSO{sub 4} markers could be detected in the CBCT. In the OBI and fluoroscopy images, all markers visible in the AP, but only B2(2 mm) could be identified in the lateral images. Changes of BaSO{sub 4} position were not detected in vivo (mice). The volume of the markers decreased by up to 65% and the HU increased by 22%, on average. The mean HU values around the B1, B2, and gold markers were 121.30 [standard deviation (SD): 54.86], 126.31 (SD: 62.13), and 1070.7 (SD: 235.16), respectively. The MC-simulated dose distortion for the BaSO{sub 4} markers was less than that of the commercially used markers. The dose reduction due to the gold marker was largest (15.05%) followed by stainless steel (7.92%) and titanium (6.92%). Dose reduction by B2 (2 mm) was 4.75% and 0.53% in parallel and perpendicular orientations, respectively. Conclusions: BaSO{sub 4} mixed with PBS is a good contrast agent in biodegradable polymer marker because of minimal artifacts in x-ray images and minimal dose reduction in proton therapy. The flexibility of the size is considered to be an advantage of this material over solid type fiducials.

60 APPLIED LIFE SCIENCES↗

Detection of Sodium in Highly Pure Graphite via High-Resolution Electrothermal Atomic Absorption Spectrometry with a Continuous Spectrum Source

This study is dedicated to elucidating the analytical abilities of electrothermal atomic absorption spectrometry with a continuous spectrum source (ETAAS-CSS) to detect the presence of sodium in highly pure graphite powder. In order to plot the calibration dependence for sodium detection, a special technique based on argon dilution of the atomic vapor obtained by introducing the aqueous reference solution in the atomizer is applied. The conditions for thermal pretreatment of highly pure graphite powder and atomization of sodium are established, and the sodium detection threshold is evaluated via ETAAS-CSS (2.6 × 10{sup –4} ng) as well. The validity of the results is confirmed via the sample variation method.

36 MATERIALS SCIENCE↗