Search NASA⌕ Search

SEARCH · Search NASA

Results for “validation studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64

Validating a Prognostic Scoring System for Postmastectomy Locoregional Recurrence in Breast Cancer

Purpose: This study is designed to validate a previously developed locoregional recurrence risk (LRR) scoring system and further define which groups of patients with breast cancer would benefit from postmastectomy radiation therapy (PMRT). Methods and Materials: An LRR risk scoring system was developed previously at our institution using breast cancer patients initially treated with modified radical mastectomy between 1990 and 2001. The LRR score comprised 4 factors: patient age, lymphovascular invasion, estrogen receptor negativity, and number of involved lymph nodes. We sought to validate the original study by examining a new dataset of 1545 patients treated between 2002 and 2007. Results: The 1545 patients were scored according to the previously developed criteria: 920 (59.6%) were low risk (score 0-1), 493 (31.9%) intermediate risk (score 2-3), and 132 (8.5%) were high risk (score ≥4). The 5-year locoregional control rates with and without PMRT in low-risk, intermediate-risk, and high-risk groups were 98% versus 97% (P=.41), 97% versus 91% (P=.0005), and 89% versus 50% (P=.0002) respectively. Conclusions: This analysis of an additional 1545 patients treated between 2002 and 2007 validates our previously reported LRR scoring system and suggests appropriate patients for whom PMRT will be beneficial. Independent validation of this scoring system by other institutions is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final technical report for DE-FG02-06ER54871 Multi-Machine Validation of Fluid and Gyrokinetic Turbulence Models

This final report for the DE-FG02-06ER54871 “Multi-Machine Validation of Fluid and Gyrokinetic Turbulence Models” award (previously titled “Validation of Plasma Turbulence Models” during 2006-2010) documents accomplishments made over the full funding period of 6/1/2006 – 5/31/2018. The accomplishments can be broadly divided into two groups. First are integrated experimental and computational studies of fundamental drift-wave turbulence and shear flow dynamics, carried out using the Controlled Shear Decorrelation Experiment (CSDX) linear plasma experiment at UCSD and various fluid-based simulation models. The second set of accomplishments relates to validation studies of gyrokinetic and gyrofluid turbulence models of core tokamak turbulence, generally using data from the DIII-D tokamak operated by General Atomics. A number of results bridge these areas, such as investigations into bispectral energy transfer and shear flow generation at L-H transitions, carried out on a number of different experimental platforms. Some of the key accomplishments supported by this work include (1) the first experimental observations of nonlinear shear flow generation by drift-wave turbulence in a magnetized plasma, (2) detailed documentation of nonlinear interactions and energy transfer between drift-waves and zonal flows in both linear devices and tokamaks, (3) experimental and numerical investigations of parallel boundary condition effects on resistive drift-wave turbulence, (4) pioneering development of synthetic diagnostics for core tokamak turbulence validation studies, along with a system of validation metrics, and (5) extensive investigation of the fidelity of gyrokinetic and gyrofluid turbulent transport models in tokamaks which have significantly advanced our understanding of where these models can (and can not) reproduce experimental observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A diagnostic model for studying daytime urban air quality trends

A single cell Eulerian photochemical air quality simulation model was developed and validated for selected days of the 1976 St. Louis Regional Air Pollution Study (RAPS) data sets; parameterizations of variables in the model and validation studies using the model are discussed. Good agreement was obtained between measured and modeled concentrations of NO, CO, and NO2 for all days simulated. The maximum concentration of O3 was also predicted well. Predicted species concentrations were relatively insensitive to small variations in CO and NOx emissions and to the concentrations of species which are entrained as the mixed layer rises.

Brewer, D. A.↗

Validation of two-equation turbulence models for propulsion flowfields

The objective of the study is to assess the capability of two-equation turbulence models for simulating propulsion-related flowfields. The standard kappa-epsilon model with Chien's low Reynolds number formulation for near-wall effects is used as the baseline turbulence model. Several experimental test cases, representative of rocket combustor internal flowfields, are used to catalog the performance of the baseline model. Specific flowfields considered here include recirculating flow behind a backstep, mixing between coaxial jets and planar shear layers. Since turbulence solutions are notoriously dependent on grid and numerical methodology, the effects of grid refinement and artificial dissipation on numerical accuracy are studied. In the latter instance, computational results obtained with several central-differenced and upwind-based formulations are compared. Based on these results, improved turbulence modes such as enhanced kappa-epsilon models as well as other two-equation formulations (e.g., kappa-omega) are being studied. In addition, validation of swirling and reacting flowfields are also currently underway.

Deshpande, Manish↗

Development of an Axisymmetric Afterbody Test Case for Turbulent Flow Separation Validation

As identified in the CFD Vision 2030 Study commissioned by NASA, validation of advanced RANS models and scale-resolving methods for computing turbulent flows must be supported by improvements in high-quality experiments designed specifically for CFD implementation. A new test platform referred to as the Axisymmetric Afterbody allows for a range of flow behaviors to be studied on interchangeable afterbodies while facilitating access to higher Reynolds number facilities. A priori RANS computations are reported for a risk-reduction configuration to demonstrate critical variation among turbulence model results for a given afterbody, ranging from barely-attached to mild separated flow. The effects of body nose geometry and tunnel-wall boundary condition on the computed afterbody flow are explored to inform the design of an experimental test program.

Disotell, Kevin J.↗

Validating a large geophysical data set - Experiences with satellite-derived cloud parameters

The goal of this study is to validate the global cloud parameters derived from the satellite-borne HIRS2 and MSU atmospheric sounding instrument measurements, and to use the analysis of these data as one prototype for studying large geophysical data sets in general. The HIRS2/MSU data set contains a total of 40 physical parameters, filling 25 MB/day; raw HIRS2/MSU data are available for a period exceeding 10 years. Validation involves developing a quantitative sense for the physical meaning of the derived parameters over the range of environmental conditions sampled. This is accomplished by comparing the spatial and temporal distributions of the derived quantities with similar measurements made using other techniques, and with model results. The need to work with Level 2 (point) data, rather than Level 3 (gridded) data for validation purposes is discussed, and some techniques developed for charting the assumptions made in deriving an algorithm and generating a code to produce geophysical quantities from measured radiances are presented.

Kahn, Ralph↗

AMSR2 Soil Moisture Product Validation

The Advanced Microwave Scanning Radiometer 2 (AMSR2) is part of the Global Change Observation Mission-Water (GCOM-W) mission. AMSR2 fills the void left by the loss of the Advanced Microwave Scanning Radiometer Earth Observing System (AMSR-E) after almost 10 years. Both missions provide brightness temperature observations that are used to retrieve soil moisture. Merging AMSR-E and AMSR2 will help build a consistent long-term dataset. Before tackling the integration of AMSR-E and AMSR2 it is necessary to conduct a thorough validation and assessment of the AMSR2 soil moisture products. This study focuses on validation of the AMSR2 soil moisture products by comparison with in situ reference data from a set of core validation sites. Three products that rely on different algorithms were evaluated; the JAXA Soil Moisture Algorithm (JAXA), the Land Parameter Retrieval Model (LPRM), and the Single Channel Algorithm (SCA). Results indicate that overall the SCA has the best performance based upon the metrics considered.

microwave↗

Understanding scale-dependent soft-error behavior of scientific applications

Analyzing application fault behavior on large-scale systems is time-consuming and resource-demanding. Currently, researchers need to perform fault injection campaigns at full scale to understand the effects of soft errors on applications and whether these faults result in silent data corruption. Both time and resource requirements greatly limit the scope of the resilience studies that can be currently performed. In this work, we propose a methodology to model application fault behavior at large scale based on a reduced set of experiments performed at small scale. We employ machine learning techniques to accurately model application fault behavior using a set of experiments that can be executed in parallel at small scale. Our methodology drastically reduces the set and the scale of the fault injection experiments to be performed and provides a validated methodology to study application fault behavior at large scale. We show that our methodology can accurately model application fault behavior at large scale by using only small scale experiments. In some cases, we can model the fault behavior of a parallel application running on 4,096 cores with about 90% accuracy based on experiments on a single core.

Kestor, Gokcen G.↗

Verification of the sensitivity and uncertainty-based criticality safety validation techniques: ORNL’s SCALE case study

The use of sensitivity and uncertainty-based techniques has been well-developed in the neutronic community for criticality safety applications. Sensitivity techniques calculate the first-order relative variations in keff due to relative cross-section variations by isotope, reaction type, and incident neutron energy. The result is a vector of sensitivity coefficients which is folded with prior cross-section uncertainties to calculate the so-called similarity indices. Similarity indices are integral quantities which serve as useful mathematical measures for assessing the relevance of existing or new experiments to given application conditions, representing design systems for which the models are to be validated. Despite their importance for a wide range of validation activities, the peer-reviewed literature is non-existent on the development of rigorous verification analysis for their calculated values. Thus, this manuscript proposes a simple non-intrusive method to calculate similarity indices, serving as an independent verification tool for their evaluation. The manuscript derives the theoretical basis for the proposed verification analysis. Next, the verification analysis is applied to the ORNL’s SCALE code suite which employs adjoint-based methods to calculate similarity indices. Numerical experiments using a number of well-known benchmark experiments are employed to verify the calculation of the similarity indices.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Subsonic Technology (AST) 22-Inch Low Noise Research Fan Rig Preliminary Design of ADP-Type Fan 3

This report presents results of the work completed on the preliminary design of Fan 3 of NASA s 22-inch Fan Low Noise Research project. Fan 3 was intended to build on the experience gained from Fans 1 and 2 by demonstrating noise reduction technology that surpasses 1992 levels by 6 dB. The work was performed as part of NASA s Advanced Subsonic Technology (AST) program. Work on this task was conducted in the areas of CFD code validation, acoustic prediction and validation, rotor parametric studies, and fan exit guide vane (FEGV) studies up to the time when a NASA decision was made to cancel the design, fabrication and testing phases of the work. The scope of the program changed accordingly to concentrate on two subtasks: (1) Rig data analysis and CFD code validation and (2) Fan and FEGV optimization studies. The results of the CFD code validation work showed that this tool predicts 3D flowfield features well from the blade trailing edge to about a chord downstream. The CFD tool loses accuracy as the distance from the trailing edge increases beyond a blade chord. The comparisons of noise predictions to rig test data showed that both the tone noise tool and the broadband noise tool demonstrated reasonable agreement with the data to the degree that these tools can reliably be used for design work. The section on rig airflow and inlet separation analysis describes the method used to determine total fan airflow, shows the good agreement of predicted boundary layer profiles to measured profiles, and shows separation angles of attack ranging from 29.5 to 27deg for the range of airflows tested. The results of the rotor parametric studies were significant in leading to the decision not to pursue a new rotor design for Fan 3 and resulted in recommendations to concentrate efforts on FEGV stator designs. The ensuing parametric study on FEGV designs showed the potential for 8 to 10 EPNdB noise reduction relative to the baseline.

Jeracki, Robert J.↗

On the determination of reference levels for quality assurance of flattening filter free photon beams in radiation therapy

Purpose: New definitions for some dosimetric parameters for use in quality assurance of flattening filter free (FFF) beams generated by medical linear accelerators have been suggested. The present study aims to validate these suggestions and to propose possible reference levels. Methods: The main characteristics of FFF photon beams were described in terms of: field size, penumbra, unflatness, slope, and peak-position parameters. Data were collected for 6 and 10 MV-FFF beams from three different Varian TrueBeam Linacs. Measurements were performed with a 2D-array (Starcheck system from PTW-Freiburg) and with the portal dosimetry method GLAaS utilizing the build-in portal imager of TrueBeam. Data were also compared to ion chamber measurements. A cross check validation has been performed on a FFF beam of 6 MV generated by a Varian Clinac-iX upgraded to FFF capability. Results : All the parameters suggested to characterize the FFF beams resulted easily measurable and little variation was observed among different Linacs. Referring to two reference field sizes of 10 × 10 and 20 × 20 cm{sup 2}, at SDD = 100 cm and d = dmax, from the portal dosimetry data, the following results (averaging X and Y profiles) were obtained. Field size: 9.95 ± 0.02 and 19.98 ± 0.03 cm for 6 MV-FFF (9.94 ± 0.02 and 19.98 ± 0.03 cm for 10 MV-FFF). Penumbra: 2.7 ± 0.3 and 2.9 ± 0.3 mm for 6 MV-FFF (3.1 ± 0.2 and 3.3 ± 0.3 for 10 MV-FFF). Unflatness: 1.11 ± 0.01 and 1.25 ± 0.01 for 6 MV-FFF (1.21 ± 0.01 and 1.50 ± 0.01 for 10 MV-FFF). Slope: 0.320 ± 0.020%/mm and 0.43 ± 0.015%/mm for 6 MV-FFF (0.657 ± 0.023%/mm and 0.795 ± 0.017%/mm for 10 MV-FFF). Peak Position −0.2 ± 0.2 and −0.4 ± 0.2 mm for 6 MV-FFF (−0.3 ± 0.2 and 0.7 ± 0.3 mm for 10 MV-FFF). Results would depend upon measurement depth. With thresholds set to at least 95% confidence level from the measured data and to account for possible variations between detectors and methods and experimental settings, a tolerance set of: 1 mm for field size and penumbra, 0.04 for unflatness, 0.1%/mm for slope, and 1 mm for peak position could be proposed from our data. Conclusions : The parameters proposed for the characterization and routine control of stability of profiles of FFF beams appear to be a viable solution with a strong similarity to the conventional parameters used for flattened beams. The results from three different TrueBeams and the cross-validation against a Clinac-iX suggested the possible generalization of the methods and the possibility to use common tolerances for the parameters. The data showed also the reproducibility of beam characteristics among different systems (of the same vendor) and the resulting parameter values could therefore be possibly generalized.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Filament winding cylinders. II - Validation of the process model

Analytical and experimental studies were performed to validate the model developed by Lee and Springer for simulating the manufacturing process of filament wound composite cylinders. First, results calculated by the Lee-Springer model were compared to results of the Calius-Springer thin cylinder model. Second, temperatures and strains calculated by the Lee-Springer model were compared to data. The data used in these comparisons were generated during the course of this investigation with cylinders made of Hercules IM-6G/HBRF-55 and Fiberite T-300/976 graphite-epoxy tows. Good agreement was found between the calculated and measured stresses and strains, indicating that the model is a useful representation of the winding and curing processes.

Calius, Emilio P.↗

Assessment of NDE Methods on Inspection of HDPE Butt Fusion Piping Joints for Lack of Fusion with Validation from Mechanical Testing

Studies at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington, are being conducted to evaluate nondestructive examinations (NDE) coupled with mechanical testing of butt fusion joints in high-density polyethylene (HDPE) pipe for assessing lack of fusion. The work provides information to the U.S. Nuclear Regulatory Commission (NRC) on the effectiveness of volumetric inspection techniques of HDPE butt fusion joints in Section III, Division 1, Class 3, buried piping systems in nuclear power plants. This paper describes results from preliminary assessments using ultrasonic and microwave nondestructive techniques and mechanical testing with the high-speed tensile impact test and the side-bend test for determining joint integrity. A series of butt joints were fabricated in 3408, 12-in. IPS DR-11 HDPE material by varying the fusion parameters to create good joints and joints containing a range of lack-of-fusion conditions. Six of these butt joints were volumetrically examined with time-of-flight diffraction (TOFD), phased-array (PA) ultrasound, and the Evisive microwave system. The outer-diameter weld beads were removed for the microwave inspection. In two of the four pipes, both the outer and inner weld beads were removed and the pipe joints re-evaluated. The pipes were sectioned and the joints destructively evaluated with the side-bend test by cutting portions of the fusion joint into slices that were planed and bent. The last step in this limited study will be to correlate the fusion parameters, nondestructive, and destructive evaluation results to validate the effectiveness of what each NDE technology detects and what each does not detect. The results of the correlation will be used in identifying any future work that is needed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multistage economic MPC for systems with a cyclic steady state: A gas network case study

Multistage model predictive control (MPC) provides a robust control strategy for dynamic systems with uncertainties and a setpoint tracking objective. Moreover, extending MPC to minimize an economic cost instead of tracking a pre-calculated optimal setpoint improves controller performance. This paper presents a novel multistage economic nonlinear model predictive control (E-NMPC) framework for dynamic systems operating under uncertainty, with specific application to natural gas transmission networks. A key innovation lies in the integration of cyclic steady-state (CSS) constraints within the multistage MPC formulation, enabling the controller to manage periodic operating conditions commonly observed in energy systems. A Lyapunov-based descent condition is enforced to ensure robust stability of the controller. The multistage economic MPC framework is validated on two gas pipeline case studies, where it successfully minimizes net energy consumption, respects operational constraints under uncertain demand profiles, and guides the network to optimal cyclic operation. The Lyapunov function remains bounded in both case studies, validating the robust stability of multistage E-NMPC.

03 NATURAL GAS↗

SU-E-T-344: Validation and Clinical Experience of Eclipse Electron Monte Carlo Algorithm (EMC)

Purpose: The purpose of this study is to validate Eclipse Electron Monte Carlo (Algorithm for routine clinical uses. Methods: The PTW inhomogeneity phantom (T40037) with different combination of heterogeneous slabs has been CT-scanned with Philips Brilliance 16 slice scanner. The phantom contains blocks of Rando Alderson materials mimicking lung, Polystyrene (Tissue), PTFE (Bone) and PMAA. The phantom has 30×30×2.5 cm base plate with 2cm recesses to insert inhomogeneity. The detector systems used in this study are diode, tlds and Gafchromic EBT2 films. The diode and tlds were included in CT scans. The CT sets are transferred to Eclipse treatment planning system. Several plans have been created with Eclipse Monte Carlo (EMC) algorithm 11.0.21. Measurements have been carried out in Varian TrueBeam machine for energy from 6–22mev. Results: The measured and calculated doses agreed very well for tissue like media. The agreement was reasonably okay for the presence of lung inhomogeneity. The point dose agreement was within 3.5% and Gamma passing rate at 3%/3mm was greater than 93% except for 6Mev(85%). The disagreement can reach as high as 10% in the presence of bone inhomogeneity. This is due to eclipse reporting dose to the medium as opposed to the dose to the water as in conventional calculation engines. Conclusion: Care must be taken when using Varian Eclipse EMC algorithm for dose calculation for routine clinical uses. The algorithm dose not report dose to water in which most of the clinical experiences are based on rather it just reports dose to medium directly. In the presence of inhomogeneity such as bone, the dose discrepancy can be as high as 10% or even more depending on the location of normalization point or volume. As Radiation oncology as an empirical science, care must be taken before using EMC reported monitor units for clinical uses.

60 APPLIED LIFE SCIENCES↗

Verification and Validation of COMSOL for Heat Transfer in Thin Rectangular Channels Using NACA Test Results

Currently efforts are underway at Oak Ridge National Lab (ORNL) to convert the High Flux Isotope Reactor (HFIR) from high enriched uranium to low enriched uranium fuel. In order to provide confidence to the thermal hydraulics calculations, computational fluid dynamics (CFD) simulations – simulated using COMOSOL – have been employed to calculate the pressure drop and heat transfer in the coolant. While CFD simulations provide well resolved results, turbulence models include a large amount of assumptions and must be validated for use in any safety-based analysis. In HFIR, long thin involute fuel plates are separated by coolant channels of equal size. The coolant channels are best described as thin rectangular channels. Unfortunately, there are few studies verifying and validating CFD for use in thin rectangular channels. This study seeks to bridge that gap by verifying, validating, and comparing various CFD models used in thin channels. To verify and validate CFD for use in thin channels, a series of simple analytic test cases are employed, and MMS is used to further verify the COMSOL tool and mesh geometry. For the validation, a series of tests conducted at NASA were simulated in COMSOL. The results of this study are three-fold. First, it verifies the ability of COMSOL to model heat transfer in thin channels. Second, it addresses the various aspects of CFD modeling that are of greatest concern for heat transfer simulations in the geometry. Third, and finally, it discusses the ability of various CFD models used in COMSOL to accurately predict heat transfer in narrow rectangular channels.

Howard, Trevor↗

Prediction of forces and moments for flight vehicle control effectors: Workplan

Two research activities directed at hypersonic vehicle configurations are currently underway. The first involves the validation of a number of classical local surface inclination methods commonly employed in preliminary design studies of hypersonic flight vehicles. Unlike studies aimed at validating such methods for predicting overall vehicle aerodynamics, this effort emphasizes validating the prediction of forces and moments for flight control studies. Specifically, several vehicle configurations for which experimental or flight-test data are available are being examined. By comparing the theoretical predictions with these data, the strengths and weaknesses of the local surface inclination methods can be ascertained and possible improvements suggested. The second research effort, of significance to control during take-off and landing of most proposed hypersonic vehicle configurations, is aimed at determining the change due to ground effect in control effectiveness of highly swept delta planforms. Central to this research is the development of a vortex-lattice computer program which incorporates an unforced trailing vortex sheet and an image ground plane. With this program, the change in pitching moment of the basic vehicle due to ground proximity, and whether or not there is sufficient control power available to trim, can be determined. In addition to the current work, two different research directions are suggested for future study. The first is aimed at developing an interactive computer program to assist the flight controls engineer in determining the forces and moments generated by different types of control effectors that might be used on hypersonic vehicles. The first phase of this work would deal in the subsonic portion of the flight envelope, while later efforts would explore the supersonic/hypersonic flight regimes. The second proposed research direction would explore methods for determining the aerodynamic trim drag of a generic hypersonic flight vehicle and ways in which it can be minimized through vehicle design and trajectory optimization.

Maughmer, Mark D.↗

Tau Positron Emission Tomography for Predicting Dementia in Individuals With Mild Cognitive Impairment

An accurate prognosis is especially pertinent in mild cognitive impairment (MCI), when individuals experience considerable uncertainty about future progression. To evaluate the prognostic value of tau positron emission tomography (PET) to predict clinical progression from MCI to dementia. This was a multicenter cohort study with external validation and a mean (SD) follow-up of 2.0 (1.1) years. Data were collected from centers in South Korea, Sweden, the US, and Switzerland from June 2014 to January 2024. Participant data were retrospectively collected and inclusion criteria were a baseline clinical diagnosis of MCI; longitudinal clinical follow-up; a Mini-Mental State Examination (MMSE) score greater than 22; and available tau PET, amyloid-β (Aβ) PET, and magnetic resonance imaging (MRI) scan less than 1 year from diagnosis. A total of 448 eligible individuals with MCI were included (331 in the discovery cohort and 117 in the validation cohort). None of these participants were excluded over the course of the study. Exposures included Tau PET, Aβ PET, and MRI. Positive results on tau PET (temporal meta–region of interest), Aβ PET (global; expressed in the standardized metric Centiloids), and MRI (Alzheimer disease [AD] signature region) was assessed using quantitative thresholds and visual reads. Clinical progression from MCI to all-cause dementia (regardless of suspected etiology) or to AD dementia (AD as suspected etiology) served as the primary outcomes. The primary analyses were receiver operating characteristics. In the discovery cohort, the mean (SD) age was 70.9 (8.5) years, 191 (58%) were male, the mean (SD) MMSE score was 27.1 (1.9), and 110 individuals with MCI (33%) converted to dementia (71 to AD dementia). Only the model with tau PET predicted all-cause dementia (area under the receiver operating characteristic curve [AUC], 0.75; 95% CI, 0.70-0.80) better than a base model including age, sex, education, and MMSE score (AUC, 0.71; 95% CI, 0.65-0.77; P = .02), while the models assessing the other neuroimaging markers did not improve prediction. In the validation cohort, tau PET replicated in predicting all-cause dementia. Compared to the base model (AUC, 0.75; 95% CI, 0.69-0.82), prediction of AD dementia in the discovery cohort was significantly improved by including tau PET (AUC, 0.84; 95% CI, 0.79-0.89; P < .001), tau PET visual read (AUC, 0.83; 95% CI, 0.78-0.88; P = .001), and Aβ PET Centiloids (AUC, 0.83; 95% CI, 0.78-0.88; P = .03). In the validation cohort, only the tau PET and the tau PET visual reads replicated in predicting AD dementia. In this study, tau-PET showed the best performance as a stand-alone marker to predict progression to dementia among individuals with MCI. This suggests that, for prognostic purposes in MCI, a tau PET scan may be the best currently available neuroimaging marker.

59 BASIC BIOLOGICAL SCIENCES↗