SRF Cavity High-Gradient Study at 805 MHz for Proton and Other Applications

805 MHz elliptical SRF cavities have been used for SNS as the first application for protons. At LANL, an R&D started to explore a capability of getting high-gradient cavities (40-50 MV/m) at this frequency for the future applications such as proton and muon based interrogation testing facility added to the LANSCE accelerator and a power upgrade of the LANSCE accelerator for the fission and fusion material test station. Optimized cell designs for “standard”, “low-loss” and “re-entrant” shapes, cavity test results for “standard” single-cell cavities with temperature mapping as well as surface inspection results will be presented.

43 PARTICLE ACCELERATORS↗

Higher Order Modes for Beam Diagnostics in Third Harmonic 3.9 GHz Accelerating Module

An international team is currently investigating the best way to use Higher Order Modes (HOM) for beam diagnostics in 3.9 GHz cavities. HOMs are excited by charged particles when passing through an accelerating structure. Third harmonic cavities working at 3.9 GHz have been installed in FLASH to linearize the bunch energy profile. A proof-of-principle of using HOMs for beam monitoring has been made at FLASH in the TESLA 1.3 GHz cavities. Since the wakefields generated in the 3.9 GHz cavities are significantly larger, their impact on the beam should be carefully minimized. Therefore our target is to monitor HOMs and minimize them by aligning the beam on the cavity axis. The difficulty is that, in comparison to the 1.3 GHz cavities, the HOM-spectrum is dense, making it difficult to identify individual modes. Also, most modes propagate through the whole cryo-module containing several cavities, making it difficult to measure local beam properties. In this paper the options for the HOM-based beam position monitors are discussed.

Baboi, N.↗

Resonance Excitation of Longitudinal High Order Modes in Project X Linac

Results of simulation of power loss due to excitation of longitudinal high order modes (HOMs) in the accelerating superconducting RF system of CW linac of Project X are presented. Beam structures corresponding to the various modes of Project X operation are considered: CW regime for 3 GeV physics program; pulsed mode for neutrino experiments; and pulsed regime, when Project X linac operates as a driver for Neutrino Factory/Muon Collider. Power loss and associated heat load due to resonance excitation of longitudinal HOMs are shown to be small in all modes of operation. Conclusion is made that HOM couplers can be removed from the design of superconducting RF cavities of Project X linac.

43 PARTICLE ACCELERATORS↗

Analysis of wakefield electron orbits in plasma wiggler

In relativistic laser plasma interaction, electrons can be simultaneously accelerated and wiggled in an ion cavity created in the wake of an intense short pulse laser propagating in an underdense plasma. As a consequence of their motion, the accelerated electrons emit an intense x-ray beam called laser produced betatron radiation. Being an emission from charged particles, the features of the betatron source are directly linked to the electrons trajectories. In particular, the radiation is emitted in the direction of the electrons velocity. In this article we show how an image of electrons orbits in the wakefield cavity can be deduced from the structure of x-ray spatial profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EUROPEAN XFEL-LINAC TWO-PHASE HE II FLOW SIMULATIONS

The superconducting 1.3-GHz niobium cavities of the XFEL linear accelerator will be cooled in a bath of saturated liquid He II at a temperature of 2 K. The liquid He II supply of the 1.7-km long linac is subdivided in sections of about 150 m length. In these sections a two-phase flow of He II liquid and corresponding vapor occurs. A stable stratified smooth helium flow has to be maintained for the RF operation of the cavities, to avoid any vibrations or microphonic effects. A computer code has been developed to simulate the two-phase flow patterns in the XFEL-linac, based on an existing model. The flow characteristics at different cryogenic loads and helium temperatures have been calculated. The results are shown and the consequences for the design of the XFEL-linac cryogenic system are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanical Study of Superconducting Parallel-Bar Deflecting/Crabbing Cavities

The superconducting parallel-bar deflecting/crabbing cavities have improved properties compared to conventional cavity structures. It is currently being considered for number of applications. The mechanical design analysis is performed on two designs of the 499 MHz parallel-bar deflecting cavity for the Jefferson Lab 12 GeV upgrade. The main purpose of the mechanical study is to examine the structural stability of the cavities under the operating conditions in the accelerators. The study results will suggest the need for additional structural strengthening. Also the study results will help to develop a concept of the tuning method. If the cavity is to be installed in the accelerator it should satisfy a certain design parameters due to the safety requirements (for example, pressure system requirements) which are much severe condition than the actual operating condition.

43 PARTICLE ACCELERATORS↗

Resonance Control System for the PIP-II IT HWR Cryomodule

The HWR (half-wave-resonator) cryomodule is the first one in the superconducting section of the PIP-II LINAC project at Fermilab. PIP-II IT is a test facility for the project where the injector, warm front-end, and the first two superconducting cryomodules are being tested. The HWR cryomodule comprises 8 cavities operating at a frequency of 162.5 MHz and accelerating beam up to 10 MeV. Resonance control of the cavities is performed with a pneumatically operated slow tuner which compresses the cavity at the beam ports. Helium gas pressure in a bellows mounted to an end wall of the cavity is controlled by two solenoid valves, one on the pressure side and one on the vacuum side. The resonant frequency of the cavity can be controlled in one of two modes. A pressure feedback control loop can hold the cavity tuner pressure at a fixed value for the desired resonant frequency. Alternately, the feedback loop can regulate the cavity tuner pressure to bring the RF detuning error to zero. The resonance controller is integrated into the LLRF control system for the cryomodule. The control system design and performance of the resonance control system are described in this paper.

43 PARTICLE ACCELERATORS↗

The MICE Demonstration of Ionization Cooling

Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams necessary to elucidate the physics of flavour at the Neutrino Factory and to provide lepton-antilepton collisions at energies of up to several TeV at the Muon Collider. The International Muon Ionization Cooling Experiment (MICE) will demonstrate ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization cooling channel, the muon beam passes through a material (the absorber) in which it loses energy. The energy lost is then replaced using RF cavities. The combined effect of energy loss and re-acceleration is to reduce the transverse emittance of the beam (transverse cooling). A major revision of the scope of the project was carried out over the summer of 2014. The revised project plan, which has received the formal endorsement of the international MICE Project Board and the international MICE Funding Agency Committee, will deliver a demonstration of ionization cooling by September 2017. In the revised configuration a central lithium-hydride absorber provides the cooling effect. The magnetic lattice is provided by the two superconducting focus coils and acceleration is provided by two 201 MHz single-cavity modules. The phase space of the muons entering and leaving the cooling cell will be measured by two solenoidal spectrometers. All the superconducting magnets for the ionization cooling demonstration are available at the Rutherford Appleton Laboratory and the first single-cavity prototype is under test in the MuCool Test Area at Fermilab. The design of the cooling demonstration experiment will be described together with a summary of the performance of each of its components. The cooling performance of the revised configuration will also be presented.

43 PARTICLE ACCELERATORS↗

The fast linear accelerator modeling engine for FRIB online model service

Commissioning of a large accelerator facility like FRIB needs support from an online beam dynamics model. Considering the new physics challenges of FRIB such as modeling of non-axisymmetric superconducting RF cavities and multi-charge state acceleration, there is no readily available online beam tuning code. The design code of FRIB super-conducting linac, IMPACT-Z, is not suitable for online tuning because of its code design and running speed. Therefore, the Fast Linear Accelerator Modeling Engine (FLAME), specifically designed to fulfill FRIB’s online modeling challenges, is proposed. The physics model of FLAME, especially its novel way of modeling non-axisymmetric superconducting RF cavities using a multipole expansion based thin-lens kick model, is discussed in detail, and the benchmark results against FRIB design code is presented, after which the software design strategy of FLAME and its execution speed is presented.

43 PARTICLE ACCELERATORS↗

SRF cavity instability detection with machine learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detectfast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. An unsupervised learning framework has been developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and our framework, along with recent successes in detecting anomalous cavity behavior. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Accelerator Physics↗

Physical Models for Particle Tracking Simulations in the RF Gap

This document describes the algorithms that are used in the PyORBIT code to track the particles accelerated in the Radio-Frequency cavities. It gives the mathematical description of the algorithms and the assumptions made in each case. The derived formulas have been implemented in the PyORBIT code. The necessary data for each algorithm are described in detail.

43 PARTICLE ACCELERATORS↗

Performance of First C100 Cryomodules for the CEBAF 12 GeV Upgrade Project

The Thomas Jefferson National Accelerator Facility is currently engaged in the 12 GeV Upgrade Project. The goal of the project is a doubling of the available beam energy of CEBAF from 6 GeV to 12 GeV. This increase in beam energy will be due primarily to the construction and installation of ten "C100" cryomodules in the CEBAF linacs. The C100 cryomodules are designed to deliver an average 108 MV each from a string of eight seven-cell, electropolished superconducting RF cavities operating at an average accelerating gradient of 19.2 MV/m. The new cryomodules fit in the same available linac space as the original CEBAF 20 MV cryomodules. Cryomodule production started in September 2010. Initial acceptance testing started in June 2011. The first two C100 cryomodules were installed and tested from August 2011 through October 2011, and successfully operated during the last period of the CEBAF 6 GeV era, which ended in May 2012. This paper will present the results of acceptance testing and commissioning of the C100 style cryomodules to date.

43 PARTICLE ACCELERATORS↗

Cavity dumping of an injection-locked free-electron laser

This letter reports cavity dumping of an electrostatic-accelerator-driven free-electron laser (FEL), while it is injection-locked to a frequency-stabilized 240 GHz solid-state source. Cavity dumping enhances the FEL output power by a factor of {approx}8, and abruptly cuts off the end of the FEL pulse. The cavity-dumped, injection-locked FEL output is used in a 240 GHz pulsed electron spin resonance experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma ignition and detection for in-situ cleaning of 1.3 GHz 9-cell cavities

Superconducting Radio Frequency (SRF) cavities performance preservation is crucial, from vertical test to accelerator operation. Field Emission (FE) is still one of the performance limiting factors to overcome and plasma cleaning has been proven successful by the Spallation Neutron Source (SNS), in cleaning field emitters and increasing the work function of Nb. A collaboration has been established between Fermi National Accelerator Laboratory (FNAL), SLAC National Accelerator Laboratory and Oak Ridge National Laboratory (ORNL) with the purpose of applying plasma processing to the Linac Coherent Light Source-II (LCLS-II) cavities, in order to minimize and overcome field emission without affecting the high Q of nitrogen-doped cavities. The cleaning for LCLS-II will follow the same plasma composition adopted at SNS, which allows in-situ processing of cavities installed in cryomodules from hydrocarbon contaminants. A novel method for plasma ignition has been developed at FNAL: a plasma glow discharge is ignited using high order modes to overcome limitations imposed by the fundamental power coupler, allowing in-situ cleaning for cavities in cryomodule. The plasma can be easily ignited and tuned in each of the cavity cells using low RF power. A method for plasma detection has been developed as well, which allows the detection of the plasma location in the cavity without the need of cameras at both cavity ends. The presented method can be applied to other multi-cell cavity designs, even for accelerators where the coupling for the fundamental modes at room temperature is very weak.

43 PARTICLE ACCELERATORS↗

Residual Resistance Data from Cavity Production Projects at Jefferson Lab

A fundamental limitation towards achieving high quality factors in superconducting radio-frequency cavities is the so-called residual resistance. Understanding and controlling the residual resistance has important implications towards improving the efficiency and reduce the operating cost of continuous wave superconducting linear accelerators. In this contribution we will report on the residual resistance values obtained from measurements of the quality factor of a large set of cavities, with resonant frequency between 805 MHz and 1.5 GHz, all of them processed and tested at Jefferson Lab. Surface treatments included both buffered chemical polishing and electropolishing. The results indicate an approximate value of the residual resistance of about 7-10 n Omega.

43 PARTICLE ACCELERATORS↗

Electropolishing-induced topographic defects in niobium: Insights and Implications for SRF

Electropolishing (EP) is the premier surface preparation method for high-Q, high-gradient superconducting RF cavities made of Nb. This leaves behind an apparently smooth surface, yet the achievable peak magnetic fields fall well below the superheating field of Nb, in most cases. In this work, the ultimate surface finish of EP was investigated by studying its effect on highly polished Nb samples. EP introduces high slope angle sloped-steps at grain boundaries. The magnetic field enhancement and superheating field suppression factors associated with such a geometry are calculated in the London theory. Despite the by-eye smoothness of electropolished Nb, such defects compromise the stability of the low-loss Meissner state, likely limiting the achievable peak accelerating fields in superconducting RF cavities. Finally, the impact of surface roughness on impurity diffusion is investigated which can link surface roughness to the effectiveness of heat treatments like low-temperature baking or nitrogen infusion in the vortex nucleation or hydride hypotheses. Surface roughness tends to decrease the effective dose of impurities as a result of the expansion of impurities into regions with greater internal angle. The effective dose of impurities can be protected by minimizing slope angles and step heights, ensuring uniformity.

Lechner, Eric [Thomas Jefferson National Accelerat↗

Electropolishing-induced topographic defects in niobium: insights and implications for superconducting radio frequency applications

Electropolishing (EP) is the premier surface preparation method for high-Q, high-gradient superconducting RF cavities made of Nb. This leaves behind an apparently smooth surface, yet the achievable peak magnetic fields fall well below the superheating field of Nb, in most cases. Here, in this work, the ultimate surface finish of EP was investigated by studying its effect on highly polished Nb samples. EP introduces high slope angle sloped-steps at grain boundaries. The magnetic field enhancement and superheating field suppression factors associated with such a geometry are calculated in the London theory. Despite the by-eye smoothness of electropolished Nb, such defects compromise the stability of the low-loss Meissner state, likely limiting the achievable peak accelerating fields in superconducting RF cavities. Finally, the impact of surface roughness on impurity diffusion is investigated which can link surface roughness to the effectiveness of heat treatments like low-temperature baking or nitrogen infusion in the vortex nucleation or hydride hypotheses. Surface roughness tends to decrease the effective dose of impurities as a result of the expansion of impurities into regions with greater internal angle. The effective dose of impurities can be protected by minimizing slope angles and step heights, ensuring uniformity.

Hryhorenko, Oleksandr [Thomas Jefferson National A↗

Magnetic field mapping of superconducting radio frequency cavities

Superconducting radio frequency (SRF) cavities are the fundamental building blocks of modern particle accelerators. Niobium is the material of choice to build such cavities. These cavities require a cryogenic cool-down to ~2 ? 4 K for optimum performance minimizing RF losses on the inner cavity surface. However, temperature-independent residual losses in SRF cavities cannot be prevented entirely. One of the major sources of residual losses is trapped magnetic flux. The flux trapping mechanism depends on different factors, such as surface preparations and cool-down conditions. We have developed a diagnostic magnetic field scanning system (MFSS) using Hall probes and anisotropic magneto-resistance sensors to study the spatial distribution of trapped flux in 1.3 GHz single-cell cavities. The first result from this newly commissioned system revealed that the trapped flux on the cavity surface might redistribute with increasing RF power. The MFSS was also able to capture significant magnetic field enhancement at specific cavity locations after a quench.

Parajuli, Ishwari↗